ACL 780/781 Economy Combo Tester

Similar documents
746 Wrist Strap Tester Installation, Operation and Maintenance

Art. E3 - OPERATOR GROUND CHECK DUAL SHOES AND WRISTBAND TESTER Meets IEC STD : 2007

50407 / DUAL INDEPENDENT FOOTWEAR AND WRIST STRAP TESTER

VARIABLE RESISTANCE REFERENCE PAR-809C. User Manual

Warmbier Germany, Wrist Strap & Footwear Combo Tester

Limit Comparator for Testers

3 740 Wrist strap + shoe tester

MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS

GF-30AC. Ground Circuit Tester COMPLIANCE WESTUSA. Instruction Manual

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

The Forte' Launch Controller

HAWK401-A Reverse Assistance System

Application Note APNE A Applications

Development Board ESD Benchtop Kit

Ohm Metrics Continuous Workstation Monitors Model SRM330

All 3M Products Innovation Explore 3M United States. Part # 3M ID/SKU Description Request a Quote/Information

INSTALLATION GUIDES OUTDOOR LIVING

802C System Controller Original and SMD Version

Assembly and Modular Table Power System Installation Instructions for Train Tables

Star Mini Phantom. Interior Undercover Mini LED Light. PATENTS D530,029 and D632,421. ULB9E Series

BX8848 Installation Instructions 4 Diode Wiring Kit For Motorhomes With Red Tail Lights

In the first part of this series on

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

STRESSTECH CAPABILITIES

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

PRODUCT MANUAL Gecko Wireless One Zone LED Dimmer and Receiver

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

Handyman Motor Capacitor Meter PART NO

LED Downlight Ceiling Fixtures

INQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Enhanced Mini Phantom

PSL2 Assembly guide. PSL2 Assembly guide. Resistors. Test pins. Document revision 1.1 Last modification : 30/05/08

SafetyPAT Plus A B P/N:

SS & SS SOFT-START v3.0 ASSEMBLY & INSTALLATION INSTRUCTIONS

Assembly Manual. Assembly Instructions Read Carefully 2.1. Parts included: Tools suggested: Electric Drill

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Base Power Infeed Installation for Training Tables with Modular Table Power System

Air-Purifying Smoke Absorber

OPERATING INSTRUCTIONS

Using your Digital Multimeter

WIRING THE HEATER POWER SUPPLY

Qrpkits.com 10 Watt SMT Dummy Load Assembly and Operating Manual

Switching DC Power Supply

Basic Electronics Course Part 1

POWER AMPLIFIER SERVICE MANUAL CONTENTS

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

REC-11+ REMOTE RECEIVER UNIT

User s Guide. MCM Backpack. Model BP-1. Part # 12715

DECIDUOUS FILTER ASSEMBLY INSTRUCTIONS RECOMMENDED TOOL AND SUPPLY LIST DECIDUOUS FILTER KIT PARTS LIST

Electricity. Chapter 20

SPRAYSHOP ANALIZER IMPORTANT : TO BE READ BEFORE USING THE HIGH VOLTAGE FUNCTION

BAPI-Stat 3 Room Sensor

3 Slot Payphone Controller

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

Installing the RT-50A Rain Tracker on a Toyota Prius 2010 (v3 European model)

2xVCX version 1.0. Calibration instructions can be found on the last page. Capacitor bypass MLCC X7R mm pin pitch

1. Connect the Tester to the L300 FS Cuff plug holes. See Figure Figure 11-1: Tester connected to the L300 FS Cuff.

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

8.2 Electric Circuits and Electrical Power

Model Volt-Amp-Wattmeter INSTRUCTION MANUAL

Cable Length Meter INSTRUCTION MANUAL

Chapter 2. Battery Charger and Base Assembly

L5000 Plus. Installation & Setup Guide

NEXUS. Introduction SENSOR MODULE &

ECO-6 & Installation Manual

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

MALLORY FIRESTORM CD MULTI COIL HARDWARE INSTALLATION - PN 69050S / 69050R

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

HT-2000 Dielectric Withstand Tester Volts AC Output

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

AC/DC ELECTRICAL SYSTEMS

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

HP10134 & HP10135 KITS BASIC SIMULTANEOUS AIR SPRING ACTIVATION KIT

Tip: LED Lighting for the 4367 SBB Euro City Set, 4366 and 4368 Cars Date: , Corrections Modified , Photos

Circuit Basics and Components

Assembly and User Guide

Contents. DX Ignition Page 2

Assembly Instructions for the KA Electronics Flat MM Phono Preamplifier

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

SUPER AUTO EJECT AUTOMATIC SHORELINE DISCONNECT 3 YEARS WARRANTY. Assembled in the UK by LUDO McGURK TRANSPORT EQUIPMENT LTD WILMSLOW - U.K.

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

THE SUPER 16 AUTO EJECT

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

AviStart 3000 Installation Manual

INTRODUCTION BASIC OPERATION FINAL CHECK OPERATION TEST CONNECTIONS BASIC IGNITION TESTS. For more information, see

Star Mini Phantom. Interior Undercover Mini LED Light. PATENTS D530,029 and D632,421. ULB9LDC Series (Lineum LED Dual Color)

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

LAB 3 SeaMATE PufferFish Practice Board

Transcription:

ACL 780/781 Economy Combo Tester OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every twelve months. 840 W. 49 th Place Page 1 of 12 info@aclstaticide.com

INTRODUCTION Get the performance of a state of the art tester for a cost effective price. The 780/781 Economy Combo Tester will individually and simultaneously test each wrist strap and heel grounder for proper connection and resistivity values in less than three seconds. With speed, ease and clarity, colored LED shows test results. No computer is necessary for pass/fail testing so you don t pay for features you don t need. FEATURES Tests wrist strap and heel grounders individually and simultaneously No switch flipping or foot changing Automatic calibration Measures from 10 5 ohms (100 kilohms) to 10 8 (100 megohms), with an option to 10 9 (1000 megohms) Conforms to US EOS 20/20 standard and European standards Adjustable resistivity limits NIST traceable calibration certificate included AC or DC powered OK, failure warning, and low battery LED display; buzzer sound Can be mounted on the wall or used on optional heavy duty stand ACL 780 includes Tester and Heavy Duty Footplate (as shown below). ACL 781 includes Tester, Heavy Duty Footplate and Stand. 840 W. 49 th Place Page 2 of 12 info@aclstaticide.com

SPECIFICATIONS Display: red, yellow, and green LED with buzzer sound Accuracy: ± 15% Weight: 1.0 lb (454 g) Environment: 32 F to 100 F (0 C to 38 C); 15% to 85% RH. Testing Range: 10 5 10 8 ohms Wrist Straps: o High Range: 2M, 5M, 10M, 25M, 35M, 50M, 75M, 100M ohms o Low Range: 500k, 750k ohms Footwear: o High Range: 2M, 5M, 10M, 25M, 35M, 50M, 75M, 100M ohms o Low Range: 500k, 750k ohms INSTALLATION GUIDE 1. Select a suitable site near an AC power outlet if adapter is to be used. If outlet is unavailable, use 9 volt alkaline battery. Do not use both, as the battery may overheat. 2. If testing heel grounders, select location for foot plate. 3. If wall mounting, select a location approximately five feet up from the floor. Before mounting, it is recommended to plug the footplate lead into the meter to ensure there is enough wire available to reach tester. 4. Drill four.20 inch diameter (5mm) holes at the marked positions in a 2.5 rectangular pattern. Insert the plastic wall anchors and attach screws through the hook disc into the wall. 5. Attach the enclosed adhesion strips to the mounted anchors. Peel off the adhesive backing covers to expose the adhesive. Press meter against exposed adhesive to mount meter to the wall. 6. To remove the meter from the hook and loop strips, gently lift the meter with two hands from the bottom corners. 7. The meter can also be attached to work surfaces using two adhesive backed hook and loop strips provided. OPERATION It is important to test wrist straps and footwear daily to ensure their proper function and to minimize charge generation on the human body, which may cause damage to integrated circuits. Wrist straps and heel grounders are the primary means by which electrical charges are drained from the body. Too fast a drain will cause sparking, field generation, and failures. Too low an electrical path can cause electrical shock. Too high an electrical path can cause integrated circuit damage. To adapt to ISO certification, the results should be recorded and monitored. 840 W. 49 th Place Page 3 of 12 info@aclstaticide.com

Wrist Straps The 780/781 Economy Combo Tester will verify that there is a safe and continuous electrical path between the user, wrist strap and the ground cord. When using the meter for wrist strap testing or monitoring, the following is suggested: 1. Position the selector switch located on the front of the meter into the wrist strap position. 2. Put the wrist strap on with the ground cord attached. Be sure the strap is in snug contact with the wrist. Dry skin, hair, or foreign contaminants may cause failures for well functioning wrist straps that are within specification. 3. Insert the end of the ground cord into the wrist jack located on the front of the Combo Tester. 4. Press and hold test button until the LED illuminates. 5. If the green OK LED illuminates, the wrist strap is functioning within the resistance specification range and therefore may be used while handling static sensitive devices. 6. If the red High Warning or red Low Warning LED illuminates and the buzzer activates, the worker must test the wrist strap cord immediately. To test a faulty cord, leave the cord plugged into the meter and detach the wrist cord from the strap. Press the wrist strap metal snap end of the cord against the metal test button, avoiding skin contact. If the cord tests fail, replace the cord. 7. If the cord passes, tighten the band cuff around wrist and retest using the cord. If it continues to fail, apply ESD hand lotion to wrist area and repeat test. Replace wristband if failure continues. Footwear 1. Position the footplate on the floor directly in front of the Combo Tester. Check to ensure the plate does not slide when the meter is being used. 2. Insert the 3.5mm stereo plug into socket marked Heel Plate on the base of the meter. 3. Position the selector switch on the front of the meter to the Dual Heel Foot Plate position. 4. Stand on the foot plate making sure that each foot is aligned on the left or right stainless steel pad. 5. Press and hold test button until an LED illuminates. 6. If the green OK LED illuminates, the ESD shoes or heel grounders are functioning within specifications. 7. If either of the Low Warning or High Warning red LEDs illuminate accompanied by the activation of the buzzer for either foot, then the user should check the shoe or heel grounder. Check heel grounder for good skin contact and dirt contamination. Wrist Straps & Footwear The ACL 780 Economy Combo Tester will test both feet and wrist strap simultaneously. If there is a failure, the meter defaults in the following order: right foot, left foot, wrist. 1. Position the selector switch between the wrist and heel positions, in the Wrist/Foot position. 840 W. 49 th Place Page 4 of 12 info@aclstaticide.com

2. Position the foot plate on the floor directly in front of the Combo Tester. Check to ensure the plate does not slide when the meter is being used. 3. Insert the 3.5mm stereo plug into socket marked Heel Plate on the base of the meter. 4. Stand on the foot plate making sure that each foot is aligned on the left or right stainless steel pad. 5. Put the wrist strap on with the ground cord attached. Be sure the strap is in snug contact with the wrist. Dry skin, hair, or foreign contaminants may cause failures for functioning wrist straps that are within specification. 6. Insert the end of the wrist strap s ground cord into the wrist jack located on the front of the Combo Tester. 7. Press and hold the metal test button until an LED illuminates. 8. If the green OK LED illuminates, then the ESD shoes or heel grounders and wrist strap are functioning within specifications. 9. If there is a failure, the meter defaults in the following order: right foot, left foot, wrist. If either of the Low Warning or High Warning red LEDs glow accompanied by the activation of the buzzer for either foot, then the user should check the shoe or heel grounder. Check heel grounder for good skin contact and dirt contamination. 10. If either red High Warning or red Low Warning LED illuminates and the buzzer activates, the user must test the wrist strap cord immediately. To test a faulty cord, leave the cord plugged into the meter and detach the wrist cord from the strap. Press the wrist strap metal snap end of the cord against the test button, avoiding skin contact. If the cord tests fail, replace the cord. 11. If the cord passes, tighten the band cuff around wrist and retest using the cord. If it continues to fail, apply ESD hand lotion to wrist area and repeat test. Replace wristband if failure continues. 840 W. 49 th Place Page 5 of 12 info@aclstaticide.com

TESTER ADJUSTMENTS The ACL 780/781 Economy Combo Tester is calibrated to NIST traceable standards. The tester can be adjusted for various electrical resistances by opening the meter case and pressing the dipswitches corresponding to the desired test ranges. These resistance ranges depend on what test standard (i.e. EOS, CECC) the user follows. The user must know what resistance range values are acceptable for their wrist straps, shoes, and heal grounders. The ACL 780/781 Economy Combo Tester comes preset to EOS/ESD recommended test limits and are represented in bold. Foot Low sw1.5m off.75m ON (US & IEC default) Wrist Low sw2.5m off.75m ON (US & IEC default) Foot High sw3 sw4 sw5 2M off off off 5M ON off off 10M off ON off 25M ON ON off 35M off off ON (IEC & CECC default) 50M ON off ON 75M off ON ON 100M ON ON ON (US default) Wrist High sw6 sw7 sw8 2M off off off 5M ON off off 10M off ON off (US default) 25M ON ON off 35M off off ON (IEC & CECC default) 50M ON off ON 75M off ON ON 100M ON ON ON 840 W. 49 th Place Page 6 of 12 info@aclstaticide.com

CALIBRATION CHECK The ACL 780/781 Economy Combo Tester can be adjusted to various electrical resistance specifications (limits) depending on what test standard (i.e. EOS for US and CECC for Europe) the user follows or what a company requires. To change settings, open the ACL 780/781 Economy Combo Tester and adjust the dip switches to desired resistance value. (See below for values.) If calibration traceable to NIST is desired, send to the ACL Meter Department in order to determine and trace accuracy. Remember the ACL 780/781 Economy Combo Tester cannot be calibrated. The meter s accuracy can only be checked. The meter has resistor and capacitor on the circuit board. Every time the tester is used, it self calibrates against this 1% resistor. 1. Purchase 1% resistors on each side of the resistance value that is set in the meter. Factory settings (in bold) require the following resistors. a. Foot Low (.75M) 675k & 825k b. Wrist Low (.75M) 675k & 825k c. Foot High (100M) 90M & 110M d. Wrist High (10M) 9M & 11M 2. Solder, clip or twist wires to both ends of the resistors. a. Attach one end of the resistor to the stainless steel button on the front of the meter using an alligator clip and piece of aluminum tape. Alternatively, the banana plug can be held to the button. b. Attach the other end of the resistor to the receptacle that is being tested using the appropriate plug attachment: banana plug or stereo plug for wrist, stereo plug for testing footplate. When the feet are checked, both the right and left leg of the circuit must have a load on the wire. If not, the unloaded leg will buzz. To accomplish this, a stereo plug with two pigtail wires must be used. Each of these two wires must have a resistance load on one end. The other end must be attached to the button using an alligator clip and piece of aluminum tape or help to the button. 3. To begin test: a. Position selector switch to Wrist setting when testing the wrist limits or the Foot setting when testing the foot limits. Remember when testing feet a stereo plug is inserted into the jack that usually has the foot plate plug inserted. The other end has the resistor attached. b. When testing wrist limits, plug resistor in wrist strap plug in. When testing foot limits, insert two resistors into the plug in jack usually used for the foot plate. 4. Press the test button and compare to the resistance range to be calibrated. 840 W. 49 th Place Page 7 of 12 info@aclstaticide.com

5. Release the test button and compare the pass or fail response to limits being tested. 6. Since the meter is self calibrating and self zoning there is no adjustment necessary. CALIBRATION USING THE ACL 795 CALIBRATION BOX TO TEST WRIST STRAPS 1. Connect the red test lead to the common point banana jack labeled "To Push" on the ACL 795 Calibration Box. 2. Connect the opposite end of the red test lead to the power button on the ACL 780/781 Economy Combo Tester using the alligator clip and a piece of aluminum tape. 3. Attach the other test lead to the wrist strap jack in the ACL 780/781 Economy Combo Tester. Then insert other end of the wrist strap cord to the wrist strap jack located on the front of the calibration unit corresponding to the resistance value being tested. 4. Position the selector switch on the ACL 780/781 Economy Combo Tester to Wrist Strap. 5. Press the power button and observe results on both the meter and on the tester s display. Green indicates a passing test. Red indicates failure. 840 W. 49 th Place Page 8 of 12 info@aclstaticide.com

TO TEST FOOTWEAR 1. Connect the red test lead to the common point banana jack labeled "To Push" on the ACL 795 Calibration Box. 2. Connect the opposite end of the red test lead to the power button on the ACL 780/781 Economy Combo Tester using the alligator clip and a piece of aluminum tape. 3. Position the selector switch to Dual Heel Foot Plate. 4. Using the lead with the split cable, plug the stereo 3.5 mm lead into the foot plate jack on the bottom of ACL 780/781 Economy Combo Tester and attach the other two ends into the test resistance test limits in the ACL 795 Calibration Test Box. The ends can be inserted into different values in order to test each foot at different resistance values. 5. Press down on tester with enough pressure to activate the test circuit. Observe the LED's for the proper response as indicated below. Be sure to hold cables at an insulated point, so that the resistance value is not affected by the body. 840 W. 49 th Place Page 9 of 12 info@aclstaticide.com

OPTIONAL ACL 740 DOOR RELAY WIRING AND SPECIFICATIONS ACL 740 door opening option: Both wires connect to customer s door relay. The wires can be disconnected from the meter via bayonet connection. Units that are ordered with an ACL 740 door opening relay option will be equipped with two pigtail wires found on the right side of the unit. There are two male bayonet type plugs attached to these wires. There are two unwired female jacks attached to these male plugs, which can be attached to the open/close schematics on the door/bell circuit board (connected to the door mechanism). The relay in the ACL 780/781 Economy Combo Tester is a single throw, low voltage single pole normally open relay. When the user passes a test, the relay is activated and remains closed for about 3 5 seconds after the user releases the test button. Units manufactured after 1/30/2006 have an activation time adjust trimpot in them which can be used to set the door open time. 840 W. 49 th Place Page 10 of 12 info@aclstaticide.com

The relay is rated.5 amps at 24 volts. Please refer to the schematics of a footplate door opening mechanism. Substitute the two wire door wires for the two wire connection of the door foot switch or hand switch. 840 W. 49 th Place Page 11 of 12 info@aclstaticide.com

The door in a facility has a second relay, usually of a higher voltage of 110 or 220VAC that allows voltage into the door electrical motor that opens and closes a door. This relay can be activated by a press button, a proximity sensor, or a floor switch as in a super market. When a person passes the combo meter strap tests, the low voltage relay in the combo meter is closed thus allowing current to pass into the higher voltage door relay and activate the motor in the door. When the low voltage relay in the meter opens the reverse happens the high voltage relay in the door is opened thus stopping the door current, and the door closes. If the door relay contact is in series with a high current inductive load door latch such as a large solenoid or electromagnet, then arcing can develop across the relay contact when the contact breaks the circuit, and shorten the relay life. To prevent relay contact arcing if the contact current is DC, then a diode (such as a1n4003 or 1N4004) across the coil leads, with cathode (band side) on the positive lead, may be wired across the contacts. The diode should have a PIV (peak inverse voltage) rating of at least twice the DC voltage. To prevent relay contact arcing if the contact current is AC, then two zener diodes back to back (band to band) may be wired across the coil leads. The zener voltage should be at least twice the AC voltage. If running 24VAC (30VAC open load?), use two 60 volt 1N5371B zeners. 840 W. 49 th Place Page 12 of 12 info@aclstaticide.com