RIGrunner. for models 4004USB 4005 / 4005H 4008 / 4008H

Similar documents
RIGrunner. for models 4004USB H H

RIGrunner. for model.

RIGrunner 4007U

DC-to-GO Battery Box

U1 Battery Buddy DC-to-GO w/ RIGrunner 4005

DCtoGO Battery Box w/ RIGrunner 4008 and Super PWRgate PG40S

DC-to-GO Battery Box w/ RIGrunner 4007U and Super PWRgate PG40S

Super PWRgate PG40S Spring City Drive Waukesha, WI

CBA Charge Controller

Epic PWRgate Spring City Drive Waukesha, WI

CLEAN POWER TM CPS Series Operator s Manual

CBA A2 Amplifier 2000W System

CBA A2 Amplifier 1000W System

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

This document describes:

Transceiver Voltage Conditioner

This document describes:

SB SWITCH CONTROL BOX

User Guide. Model No.: GDI-GFD7200

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Matson Jump Starter Operator s Manual

Building a DC Uninterruptible Power Supply for Your Ham Shack

600 Amp Battery Jumper with Air Compressor

Installation and Operation Guide

Installation Instructions for: Channel Thermocouple Amplifier

Installation and Operation Guide

Infinitybox Express Road Race Car Kit Installation Guide

IMPORTANT SAFETY INSTRUCTIONS

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

You re never left in the dark.

Page 1 of 5 FL-4020 FLUORESCENT BALLAST CONTROLLER

JUMP STARTER OPERATOR S MANUAL RA1900

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

XMODS Street RC Starter Kit User s Guide

Operating Instructions

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

Owner s Manual & Safety Instructions

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

BRAVO Inverter/Battery Charger. Table of Contents

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

LESTRONIC II BATTERY CHARGER MODEL 19740

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

User Guide IGD Series

Item no Smart AC 200 USB. User s Manual

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

For technical questions and replacement parts, please call

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

USER GUIDE EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY INTELLIBOOST ULTRA RG600 12V 600A REV 1.16B

DC to DC Step Up Converter Model: VTC305

BATTERY SAVER LOW RIPPLE HO

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Table of Contents. Introduction. How Your Cobra Power Inverter Works. Rechargeable Appliances 1. Quick Checkout 2-3. Operation 4

VTC1000 Series Voltage Converter. Installation & Operation Manual

Model RP310 Owner's Manual & Installation Instructions

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

Installation & Operation Manual PWS1000R Rack Mount Power Supply

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER

CYCLONE PocketMax PP-1000 Compact Battery Pack for Portable Flashes. User Manual

AUTO CHARGE D PUMP PLUS

Table of Contents. How the Surestart SE 433 Operates Starting the Vehicle with the Remote Starter... 3

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

ATD-5540 Digital Automotive Engine Analyzer/Multimeter Owner s Manual

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Installation Power Management Unit Battery Cables and Battery Harness

WARNINGS, CAUTIONS AND NOTES

O W N E R ' S M A N U A L

INSTRUCTION and OPERATIONS MANUAL. for

VTC610 Series Voltage Converter. Installation & Operation Manual

Warning Statement Read Before Riding

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

Power Inverter 400 MW Owner s Manual

BusPro Series Instruction Manual

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Pure Sine Wave Inverter 600W-24V User Manual

2/10/50 AMP 12 VOLT BATTERY CHARGER/ ENGINE STARTER

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

800 WATT POWER INVERTER

AC/DC LIPO CHARGER INSTRUCTION MANUAL

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

Operating Instructions for Your Cobra 150 Watt POWER INVERTER M ODEL CPI 150 FAULT OFF. Nothing comes close to a Cobra

BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS

INSTRUCTION MANUAL. BatteryMINDer. Model SCC515 Maintenance Charger- Solar Controller for use with 5 Watt and 15 Watt Solar Panels

Setup and Configuration Guide Universal Switch Interface

Digital Auto Multi-Tester

INSTRUCTION MANUAL FOR PC63 CAGE

Transcription:

RIGrunner for models 4004USB 4005 / 4005H 4008 / 4008H 4012 www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2015 West Mountain Radio, All rights reserved. All trademarks are the property of their respective owners.

Thank you for choosing the West Mountain Radio RIGrunner! You will enjoy having a RIGrunner with durable, standardized Powerpole connections. Having proper DC distribution should make a long overdue improvement to the convenience and safety of your station. The RIGrunner is a simple device, with obvious function. Think of a RIGrunner as the DC equivalent of a 120 VAC power panel in a house. There are some considerations to think about. Please read these instructions carefully before setting up your RIGrunner. Choosing a mounting location Pick a location that is close, or central to, most of your radios and accessories; especially those that draw large amounts of current. Locate your power source as close as possible to the RIGrunner. Remember that every wire has resistance, longer wires have more resistance. More than a 10 run of #10 wire is not quite adequate to supply the RIGrunner to full output without a significant voltage drop. Determine the voltage loss for a cable run by using the online calculator at: www.westmountainradio.com/find_cable_size.php Install in a cool dry place with good ventilation. For example, do not put it on top of your amplifier or room heater, or cover it with something. It is recommended to not put it in the engine compartment of your car, or directly on the floor of a car; rain from open windows or snow covered boots may cause water damage. Connecting your equipment Recognizing that RIGrunner comes standard with Powerpole, updating your cables that supply or use DC with Powerpole will improve the convenience of quick connections and use of your equipment. Remember, Powerpole are genderless and the same connector arrangement works for both supply and load. Powerpole can be used to charge or power batteries, all using the same connectors. Powerpole can be installed by soldering or crimping. Be sure to make good connections. For detailed Powerpole connector installation tips see RIGrunner support pages at http://www.westmountainradio.com/supportrr. IMPORTANT!! It is essential that assembly of the pairs is correct. Follow the amateur radio standard used by the RIGrunner. DO NOT PLUG IN without verifying that RED + PLUS and BLACK MINUS is correct. The far left connector is labeled DCIN with a 40 amp fuse, and is normally used to connect to the power supply; but, any output may be used as the input with an appropriate fuse. Plug in your equipment starting with the highest power connections to the left and the lower power drain units to the right, notice the supplied fuse ratings next to Powerpole is a registered trademark of Anderson Power Products, Inc. West Mountain Radio

the connector chosen. Typically amplifiers and 100 watt RF output transceivers should be first, VHF radios next and smaller accessories last. Multiple amplifiers and/or transceivers may be connected to the RIGrunner. There is a 40 amp maximum that would be exceeded if trying to transmit all connected units at once. Most radios and amplifiers draw less than 3 amps in receive, but require many more amps in transmit. Therefore, the limiting factor is total current draw while transmitting. To determine how many radios may be used to transmit at one time, consult the radio manual for power consumption specifications. In the event that the total current goes over the 40 amp maximum, a fuse will blow or make an undersized power supply unhappy. The RIGrunner and any equipment plugged into the RIGrunner should go unharmed. Voltage The 4004U, 4008 and 4012 operate from 11.5 to 15V. Contact West Mountain Radio for special versions of these RIGrunners for other specified voltages. The 4005, 4005H, and 4008H can operate on positive voltage systems up to 48V. Contact West Mountain Radio for negative voltage system devices. Using the proper fuses The RIGrunner comes supplied with a range of fuses installed. This assortment should be suitable for most stations, but can be changed easily. Every RIGrunner output is safe up to 40 amps, but the total allowable is also 40 amps. A fuse MUST be in each position in use. ANY ATTEMPT TO BYPASS OR SHORT ACROSS THE FUSES IS DANGEROUS AND VOIDS THE RIGRUNNER WARRANTY. Since the maximum available automotive fuse is 40 amps, the RIGrunner will be protected as long as any value ATC/ATO fuse is installed. Choose the correct fuse for your equipment. Standard ATC/ATO automotive blade fuses are used. These fuses are available in 10 values ranging from 1 amp to 40 amps. The DC input should have a fuse that is appropriate for the power supply rating. If using a smaller power supply, consider using a lower value fuse than the 40 amp value supplied. Ideally all of the outlets should have a fuse that is the next higher value above the maximum current draw of the unit on that fuse. If using a power cord with a fuse, match that value or go one or two values higher. Sizing each fuse for each unit is desirable, but not absolutely necessary. Having a higher value than the minimum will offer less protection for that unit, too low a value and the fuse will blow out prematurely. Note that each fuse position has a LED blown fuse indicator that will conveniently light up if an output fuse is blown. There must be power to the RIGrunner and a load on the circuit that has the blown fuse for the blown fuse LED to light. Operating Manual

The 12V voltage comparator & audible alert A feature of the RIGrunner 4012 and 4008 is the precision expanded scale voltage comparator display with audible alert. (The 4004U, 4005, 4005H and 4008H models do not have this feature.) A basic explanation of 12 volt systems will aid in understanding this feature. Equipment commonly referred to as 12 volt is actually a nominal 13.8 volts. For example, a lead acid battery is a nominal 12.6 volts when charged and not under load, and approximately 14.0 volts under charge. A quality 12 volt power supply will have its regulated output set to 13.8 volts. Most radios are specified to require 13.8 volts +/- 15%. 12 volt automobile or aircraft alternators have voltage regulation set between 13.5 and 14.3 volts. The RIGrunner provides an accurate and unambiguous display of voltage. There are three LEDs: red overvoltage, green normal, and yellow undervoltage. The points at which the LEDs change are set accurately to 11.5 and 15.0 volts. The selection of these points gives a reliable indication of proper and safe operation of your power supply, battery or alternator. A green or normal indication is all you need to look for. An undervoltage indication, shown by the yellow LED, is less than 11.5 volts. This should be safe for your radio, but may cause improper operation. Low voltage on a modern radio can cause a loss of phase lock and a frequency error. This is a definite indication of a problem with the power source; a bad connection, an unregulated power supply, a bad alternator or dying battery. It is normal with most cars to have less than 11.5 volts when cranking the starter motor. A normal indication with the green LED illustrates, everything is good and you are between 11.5 and 15.0 volts, don t worry about a thing. A red overvoltage indication with the red LED is a warning, DISCONNECT OR TURN OFF YOUR POWER SUPPLY IMMEDIATELY! It is possible to overheat or damage a radio or other equipment. An overvoltage will sound an audible alert; no need to watch the LEDs to signal a problem. When running strictly on a 12 volt battery, an overvoltage condition will not occur. The RIGrunner s audible alert can be reconfigured for a low battery warning. By removing the four cover screws and move the P14 jumper to the LO position. Remember to move it back to HI when changing back operation from power supply or alternator. Note: Due to the characteristics of the comparator chip it is normal for the undervoltage LED to glow very dimly with a normal or overvoltage indication. It is also normal for the LEDs to change intensity while stepping through 10 precision points. In the event of a bad power source or power connection, the yellow LED may flash or come on during transmit. If this happens, check the power source and connections. It is also possible for RF from a transmitter to cause an electronically regulated power supply to lose regulation and cause an overvoltage alert during transmit. The RIGrunner is extensively RF bypassed and should actually cure this West Mountain Radio

problem. If you do have an overvoltage condition during transmit especially with a VHF high power amp, it is due to inadequate RF filtering on the DC lead of the amplifier, or poor RF immunity of the power supply regulator circuit. Special Note for RIGrunner 4004USB: The maximum current for the USB outlet is 2 amps and is controlled by the type of device plugged into the USB jack. RIGrunner Accessories Order Sku# Fuse Assortment Low Value (8pcs) #58537-1085 3-1A, 3-5A & 2-10A Fuse Assortment High Value (8pcs) #58537-1086 2 ea. of 15A, 20A, 30A, 40A Buss 10A ATC Circuit Breaker #58537-1087 Buss 15A ATC Circuit Breaker #58537-1088 Buss 20A ATC Circuit Breaker #58537-1089 Buss 25A ATC Circuit Breaker #58537-1090 Buss 30A ATC Circuit Breaker #58537-1091 Powerpole Extension Cable, 3 ft. #58531-1082 #12 Red/Black Wire w/ Powerpole ends Powerpole Extension Cable, 6 ft. #58531-1083 #12 Red/Black Wire w/ Powerpole ends Powerpole Extension Cable, 10 ft. #58531-1084 #12 Red/Black Wire w/ Powerpole ends 15A. Powerpole Connector-12 Pair #58257-1093 30A. Powerpole Connector-12 Pair #58257-1095 45A. Powerpole Connector-12 Pair #58257-1099 Powerpole Retention Clips -12 Pack #58257-1092 PowerLock - RIGrunner Retainer Kit #58512-1060 PWRcrimp Crimp Tool #58568-1049 To purchase or view other accessories available, call or go online at: www.westmountainradio.com/shop Additional Resources Go to our support page for more assistance: http://www.westmountainradio.com/supportrr Go to our OpTips page for connection tips: http://www.westmountainradio.com/optips Operating Manual

Powerpole Wiring Guide Powerpole Series Contact Recommended Wire Gauge 15 A 20-16 AWG 30A 20-12 AWG 45A 14-10 AWG Additional Resources for Anderson Powerpole go to: www.andersonpower.com Details and a video demonstration for using PWRcrimp Tool with Powerpole, go to: www.westmountainradio.com/crimptool www.westmountainradio.com/videos Specifications 4004U 1.4 H x 6 W x 3.0 D 6 3/4 oz. Maximum total current 40 amps USB current charge 4A max for both ports 4005 and 4005H Voltage Maximum total current 1.4 H x 7 W x 3.0 D 6 3/4 oz. Positive up to 48 VDC 40 amps West Mountain Radio

4008 Maximum total current Precision comparator window points Metering accuracy Audible alert SPL output Maximum voltage (meter circuit) Reverse polarity protection (meter circuit) 4008H Voltage Maximum total current Precision comparator window points 4012 Maximum total current Precision comparator window points Metering accuracy Audible alert SPL output Maximum voltage (meter circuit) Reverse polarity protection (meter circuit) 1.4 H x 9 W x 3.0 D 11 1/4 oz. 40 amps 11.5, 15.0V better than 2% @ 25 deg. C ~60dB SPL @ 1 meter 32 volts Yes 1.4 H x 9.75 W x 3.0 D 11 1/4 oz. Positive up to 48 VDC 40 amps 11.5, 15.0V 1.4 H x 11.75 W x 3.0 D 15 1/4 oz. 40 amps 11.5, 15.0V better than 2% @ 25 deg. C ~60dB SPL @ 1 meter 32 volts Yes Operating Manual

RIGrunner Warranty The RIGrunner is warranted against failure due to defects in workmanship or materials for one year after the date of purchase from West Mountain Radio or an authorized dealer. If purchased from an authorized dealer it must be returned with a copy of the original sales receipt or proof of purchase. Warranty does not cover damage caused by abuse, accident, misuse, improper or abnormal usage, failure to follow instructions, improper installation, alteration, lightning, or other incidence of excessive voltage or current. If failure occurs within this period, return the RIGrunner or accessory to West Mountain Radio at your shipping expense with a full explanation and necessary proof of purchase. The device or accessory will be repaired or replaced, at our option, without charge, and returned to you at our shipping expense. Repaired or replaced items are warranted for the remainder of the original warranty period. You will be charged for repair or replacement of the RIGrunner or accessory made after the expiration of the warranty period. West Mountain Radio shall have no liability or responsibility to customer or any other person or entity with respect to any liability, loss, or damage caused directly or indirectly by use or performance of the products or arising out of any breach of this warranty, including, but not limited to, any damages resulting from inconvenience, loss of time, data, property, revenue, or profit, or any indirect, special incidental, or consequential damages, even if West Mountain Radio has been advised of such damages. Except as provided herein, West Mountain Radio makes no express warranties and any implied warranties, including fitness for a particular purpose, are limited in duration to the stated duration provided herein. www.westmountainradio.com 1020 Spring City Drive, Waukesha, WI 53186 tel 262-522-6503 fax 262-522-6504