CUL INVERTER/CHARGER OWNER'S MANUAL

Similar documents
BRAVO Inverter/Battery Charger. Table of Contents

LifeStar Ambulance Inverter

VLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B

WF-5110R True Sine Wave Inverter

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

WF-5110R True Sine Wave Inverter

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

IQC IQC IQC

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

DC to AC Power Inverters

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

DC to AC Power Inverters

WF-5100 Series True Sine Wave Inverters

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

1000 Watt Pure Sine Wave Power Inverter, Users Manual

GSL Electronics Modified Sine Wave Power Inverters

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

OWNERS MANUAL JANUARY 2007 ISO

ADI-125/750 ADI-125/1500 ADI-125/2500

Table of Contents 文管中心 發行章

MIL-24/2600Q MIL-24/3200DQ

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

OWNERS MANUAL JANUARY 2007 ISO

WARNINGS, CAUTIONS AND NOTES

Power Inverter 400 MW Owner s Manual

Section 1 Introduction... 1

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

70-Series Power Management System. With Internal Electronic Monitor

S150,S300 Series Pure Sine Wave Inverter User s Manual

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

DC TO AC POWER INVERTER

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

Pure Sine Wave Inverter Charger

Infinitybox Express Road Race Car Kit Installation Guide

Pure Sine Wave Inverter User Manual

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

The Power of Reliability INSTRUCTION MANUAL

1200+ WITH TIMER V1.00 OWNERS MANUAL

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

230VAC Power Inverter 400W Owner s Manual

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

O W N E R ' S M A N U A L

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

DC to AC Power Inverter Pure Sine Wave Output. Owner s Manual. Models: 12LP10 12LP10H 12LP10R

RU BMS Power Supply and Battery Management System Owners Guide

Airpax Dimensions, Inc.

MODEL NUMBER: APS2012

PureSine 150/300 Pure Sine Wave Inverter User s Manual

CLEAN POWER TM CPS Series Operator s Manual

Go Power! Manual. GP-Smart Charger

AC CONVERTER / BATTERY CHARGER

HPP1 MK6-15A/20A R00 Owners Manual

This file was converted to PDF format. If you are interested in a Microsoft PowerPoint formatted file send a request to:

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

3000W APS X Series 24VDC 230V Inverter/Charger with Pure Sine-Wave Output, Hardwired

PHOTO VOLTAIC CHARGE MODULE MULTI POINT TRACKING

2400W APS INT Series 24VDC 230V Inverter/Charger with Auto-Transfer Switching, Hardwired

Installation and Operation Manual. Dual Battery Charging Solar Controller. for RVs, Caravans, and Boats. Ratings. Rated Solar Current 25 Amps

HPP1 MK5 Owner s Manual

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

MODEL NUMBER: APS2424

Battery Equalizer. Table of Contents Introduction. 2. Specifications.. 3. Theory of Operation Typical Applications... 5

APOLLO Gate Operators, Inc.

MODEL NUMBER: APS2448UL

StartSentry. UCS-80Kj and UCS-80KjC. Ultra Capacitor. Table of Contents

AUTOMATIC BATTERY CHARGER

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

MODEL NUMBER: APS3636VR

THE DLS SERIES BATTERY CHARGING POWER CONVERSION

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

BZ Products Inc. U.S.A.

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual. Model: SS-MPPT-15L

AUTO CHARGE D PUMP PLUS

600 Amp Battery Jumper with Air Compressor

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

PROwatt 150 DC to AC Power Inverter. Owner s Guide

750W PowerVerter RV Inverter/Charger with Hardwire Input/Output

Manual Installation & Operation

The Traveler Series: Wanderer

INSTRUCTION MANUAL CAUTION

This document describes:

Intelligent Charging System Series

J1939 POWERCELL Setup and Configuration Guide Universal Switch Interface

Installation Instructions & Users Manual

Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra

Cruising Charger Series OWNER S MANUAL

Transcription:

Table of Contents Section 1 Introduction...1 Section 2 Installing the 20-1050CUL... 4 Section 3 Installing the IFM1 Interface Module...6 Section 4-- Installing the Inverter & Charger Remote Panels... 8 Section 5 Inverter & Charger Remote Panel Operation... 9 Section 6 Operating the 20-1050CUL Inverter/Charger... 10 Section 7 Troubleshooting... 11 Section 8 GFCI Test Record... 12 Warranty... 13 List of Figures Figure 1 System Diagram... 2 Figure 2 Federal Specification KKK-A-1822D Diagram... 7 Figure 3 1FM I Module Remote Wiring... 8 Icon Legend Note Warning VANNER INC. 4282 Reynolds Drive, Hilliard, Ohio 43026 800-AC POWER Tel (614) 771-2718 Fax (614) 771-4904 www.vanner.com 20-1050CUL--OWNERS MANUAL c Copyright 1996, Vanner, Inc. OM/A96283 REV. B ii

Section 1: Introduction Thank you for purchasing a Vanner 20-1050CUL Power Inverter/Battery Charger for your emergency vehicle. We are confident you will be satisfied with its performance. Vanner products are designed and manufactured by skilled professionals using the highest standards in workmanship, guaranteeing excellent performance and reliability for your emergency vehicle. With minimum maintenance and care, you can expect years of trouble-free service from your Vanner product. The 20-1050CUL is a 12 VDC to 120 VAC inverter with a built-in battery charger/conditioner and transfer relay. This unit is equipped with an AC line cord for connecting AC input power (shore/utility power) and a receptacle with a Ground Fault Circuit Interrupter (GFCI) for AC output. This enables you to plug AC loads directly into the inverter. The DC cables have quick connectors to facilitate installation and pre-wiring of emergency vehicles. 1

FUNCTIONALITY Inverter The 20-1050CUL converts battery power to 1050 Watts of 120 VAC modified sine wave power to operate vital emergency vehicle equipment. The unit is easily connected to the positive and negative posts of a battery system with appropriate fusing, and when turned on produces 120 VAC True RMS power. WARNING Battery input cables The inverter also has an energy-saving feature called Load Demand. With this feature the must be connected to inverter output is pulsed significantly reducing the current draw from the battery until a the battery demand is made on its output. Continuous output of 120 VAC resumes when a load greater than 5 with proper polarity to avoid damaging the inverter. Watts is applied. The load demand feature can be disabled with the Setup Switch on the front panel. A built-in transfer relay switches the AC output receptacle from the inverter to the AC input when the unit senses AC input from the shore/utility power. NOTE If the battery is fully charged at the time AC input is applied, the unit will go directly into Ready/ Maintenance mode. Battery Charger The 20-1050CUL Battery Charger's superior design incorporates a multi-stage charger. This design enables the unit to automatically charge batteries, maintaining the battery's integrity and reducing the likelihood of premature failure. High Charge Mode While in the High Charge mode, the unit continuously charges at a constant current of 55 Amps (high setting) for large battery banks, or 15.0 Amps (low setting) for small battery banks (such as two group 31 batteries). The unit will charge until the battery cells reach 14.2 VDC for flooded batteries. or 19.1 VDC for gel batteries. The unit then supplies a fixed voltage until the battery is fully charged. Ready/Maintenance Mode The charger automatically enters the Ready/Maintenance mode, maintaining the battery's proper voltage of 13.2 VDC for flooded batteries or 13.6 VDC for gel batteries. This Ready/Maintenance mode is designed to eliminate gassing (overcharging), helping to extend the life of the battery. A Setup Switch is located on the front panel for selecting the type of battery (Flooded Lead Acid or Gel Lead Acid), the battery charger output current (High/Low), and Load Demand(On/Off). 2

Specifications Inverter Output at 120 VAC RMS (Continuous Power Rating) Surge Capacity at 120 VAC (3 sec) Input Voltage, VDC (Deep Cycle Battery Recommended) 20-1050CUL 1050 Watts 2100 Watts 12 VDC, Nominal Output Voltage 120 VAC ± 5% DC Current Draw (Battery) OFF Load Demand (waiting)* Full ON at No Load 10.5 VDC min., 16.0 VDC max. 0.017 Amps Typical 0.09 Amps Typical 0.7 Amps Typical Full ON with Load Approx. AC Load Watts 10 or AC Load Amps x 12 Frequency 60 Hz ± 0.1% Output Wave Form Battery Charger Charging Capacity* Modified Sine Wave 55 Amps (High) 15.0 Amps (Low) Input Voltage 120 VAC ± 10% Input Current Bulk Voltage* Float Voltage* Bypass Transfer Output Current, GFCI Outlet** Other Specifications AC Input Termination AC Output Termination Ambient Temperature Cooling Air Chassis Dimensions Weight 8.0 Amps 14.2 VDC (flooded), 14.1 VDC (gel) 13.2 VDC (flooded), 13.6 V (gel) 12 Amps Hardwire Box, or 3ft. Line Cord Duplex GFCI Receptacle -20 to +110 F, -29 to +43.4 C Fan Cooled, 30 cfm Aluminum 11.57 W x 5.94 H x 11.04 D 22 lbs *Determined by Setup Switch setting on front panel. **Note: If GFCI trips and the inverter is in load demand mode the GFCI may not reset until you toggle inverter off and back on and then you will have 5 seconds to reset GFCI before unit goes back into load demand again or you can disable load demand via dipswitch, if available. 3

WARNING Battery input cables must be connected to the battery with proper polarity to avoid damaging the inverter. Section 2: Installing the 20-1050CUL Unpacking the Inverter Inspect the shipping container and equipment for loose or damaged parts. If any damage is found, immediately notify the freight carrier. Installing the Inverter Step 1: Turn the inverter OFF/disconnect power to the wiring harness. Make sure power to the vehicle wiring harness is disconnected. Verify that the inverter is turned OFF by checking that the ON-OFF/RESET Inverter Switch is in the OFF-RESET position. (The button should NOT be pushed in.) D C C a b l e L e n g t h Size Maximum 2AWG 12ft. 1/0 AWG 20 ft. Note Step 2: Select a location for the unit. An ideal installation location has the following characteristics: Close to the battery (within six feet using #2 AWG wire) Protected from the weather Protected from the weather Air enters by the fan at the rear of the unit, and exits through the sides of the unit. For maximum unit performance, avoid recirculating the same hot air through the unit. Step 3: Route DC input cables. Route the negative and positive DC input cables from the inverter (through the quick connector) to the battery. If required, protect cables where they contact hard, sharp edges. Step 4: Install inline fuse. Install an inline Bussman ANN 125 or equivalent fuse (Vanner p/n 03640-fuse and 03637-fuse holder) in the red, positive DC input cable between the battery and inverter, within 18 in. of the battery or DC wiring bus system. Step 5: Connect bonding lug. Use a AWG #8 or larger copper conductor to connect the chassis bonding lug to the vehicle chassis and/or earth ground. 4

WARNING Battery input cables must be connected to the battery with proper polarity to avoid damaging the inverter. Step 6: Connect the inverter to the battery. Connect the black, negative DC input cable from the quick connector to the battery negative (-) terminal. This battery negative terminal is usually where the battery negative connects to the engine block or frame. Connect the red, positive DC input cable from the quick connector to the in/line fuse near the battery positive (+) terminal. This battery terminal is usually connected to the DC electrical system at the load side of the Battery disconnect Switch. Step 7: Select Load Demand option. Select Load Demand option if desired, using the proper switch position on the front panel Setup Switch. With Load demand ON, the inverter conserves battery energy and operates only when a load greater than 5 Watts is applied. Step 8: Select battery type. The charger is capable of charging both gel and flooded lead acid batteries. Select the battery type using the Setup Switch on the front panel. WARNING Improper Battery Type Switch setting may damage batteries. Step 9: Select the charging rate. In the high position the charge is 55 Amps. In the low position the output is 15.0 Amps. We recommend the low position as the best selection when two (group 31 or smaller) batteries are used. Charging at too high of a rate for a given battery will damage the batteries. Step 10: Connect the AC loads. Connect the AC loads to the inverter GFCI receptacle. Any time AC power is applied to the AC input (shore/utility power), it will pass through this GFCI receptacle. Step 11: Verify installation. Verify all connections are tight and secure for maximum performance. Inverter LED Displays Inverter Light Action Description Steady Green Light. Inverter is On and operating Single Blink Green Light Inverter circuit is Off. Shore power is On and supplying AC power to the AC loads. The inverter will turn On and supply the load if shore power is lost. Double Blink Green Light Inverter circuit is Off. Shore power is Off. The inverter is waiting for a load greater than 5 watts to be turned on. Battery Low Light Action Description Solid red Inverter is On and the battery is almost too low to operate the inverter. Blinking Red The inverter is Off. The battery voltage dropped below 10.5 volts DC and the inverter shut itself Off. Once shut off, the batteries must be recharged. Then, the inverter On/Off switch must be cycled to reset the unit. 5

Inverter LED Displays cont. Overtemp Light Action Description Solid red The unit is Off. The unit has turned itself Off because the power MOSFET's are operating too hot. This can be caused by operating an AC load which is too large for the inverter, or lack of ventilation. When the unit cools the inverter will start operating again. Overload Light Action Description Blinking Red The inverter is On but it is overloaded. Reduce the AC load quickly or the inverter will shut off due to the overload condition. Charger High Charge Solid red Light Action Blinking Yellow The inverter is Off. An overload has occurred and the inverter has shut off to protect itself. Once shut off, the inverter On/Off switch must be cycled to reset the unit. Description The charger is operating. The batteries were low and in need of a charge. The charger is in the process of charging the batteries to the bulk voltage. The charging current is limited based on the position of the Charger High/ Low switch. Charger Ready/Mainten ance Light Action Solid Green Description The charger is operating. The batteries are near full charge and the charger is in the maintenance mode. In this mode, the charger is holding the batteries at the float voltage. The charging current is limited based on the position of the Charger High/Low switch. Section 3: Installing the IFM1 Interface Module This section describes the installation of the optional Vanner Model IFM 1 Interface Module. Refer to the information provided in the IFM 1 Interface Module Owner's Manual for information on installing the inverter and interface module in a vehicle rewired or retrofitted for the 20-1050C UL. If you are installing a new 20-1050 CUL unit, you will need the interface module only if you are using the inverter or charger status panels (p/n D06638 or D06639), Remote Switch (pin D06781), or if you need to use the inverter lockout feature. NOTE Refer to the IFM1 manual for Pin identification and description. Installing the IFM1 Interface Module Step 1: Mount the Interface Module. Mount the interface module in the vehicle's existing 12 V electrical system wiring harness with #8 screws. Select a physical orientation best suited for your application environment; however, it must be close to the inverter as the interface cable is 2 ft. in length. Additionally, the unit should not be installed with pin connections facing upward. Step 2: Connect the inverter to the Interface Module. Install the 2 ft. interface cable by plugging it into the remote RJ-11 connector on the 20-1050CUL, and the J1 connector on the IFM1 Interface Module. 6

Step 3: Connect the Battery Disconnect Switch. Connect the +12 V lead from the Module Disconnect Switch circuit to the inverter lockout Pin 1 (ignition switch or battery disconnect switch). The +12 V lead from the Battery Disconnect Switch must be fused with an inline fuse or circuit breaker of 2 Amps or less. See Figure 3. Step 4: Wire the Remote Switch (p/n D06781) to Pins 2 through 5. Red to Pin 2, Black to Pin 3, Green to Pins 4 and 5. If no remote switch is used, two jumpers must be installed. The first jumper connects Pin 2 to Pin 3, the second jumper connects Pin 4 to Pin 5. See Figure 3. Step 5: Connect the Inverter Remote Status Display Panel (Optional). Connect the gray, green, and red wires from the inverter panel, through the OEM harness, to the IFM1 Module, Pins 6 (grey), 7 (green) and 8 (red). Step 6: Connect the Charger Remote Display Status Panel (Optional). Connect the brown, white, and black wires from the charger panel, through the OEM harness, to the IFM1 Module, Pins 9 (brown), 10 (white) and 11 (black) 7

Section 4: Installing the Inverter and Charger Remote Status Display Panels Both the inverter and charger Remote Status Display Panels contain a red and green LED indicator. On the inverter status panel, the green indicator light signifies the unit is ON or in the Standby mode. On the charger status panel, the green light indicates the presence of shore power or that the battery is being maintained at its current level. For both the inverter and charger, the red, Fault LED indicator shows problems such as over temperature, output overload, or low battery. The panels have a sealed overlay which mounts easily on a flat surface, Each panel is equipped with a 12-in. pigtail harness for easy installation. The following installation procedure applies to both the inverter and charger panels: Step 1: Select a location for the panel. Identify the desired location for the inverter and charger panels. NOTE When the remote charge indicator panel is installed to the outside of the vehicle, the status panel should be sealed with RTV. Step 2: Identify wires for installation. Identify the gray, green, and red wires on the inverter panel and vehicle's electrical system. Identify the brown, white, and black wires on the charger panel and the vehicle's electrical system. Step 3: Splice and arrange wires. Splice together like-colored wires from the vehicle's electrical system to the status panel using an insulated butt splice or equivalent. Carefully arrange the wires such that the panel mounts flush against the surface to which it is mounted. Step 4: Secure panels to surface. Mount the panels using #8 screws through the four holes in the panel 8

Section 5: Inverter and Charger Status Panel Operation Two LEDs on the front of the Remote Status Display Panels indicate the status of the inverter and charger. The status indicated by these LED displays is directly related to the status indicated by the LEDs on the front of the inverter and charger. Inverter Led Light Action Description Steady Green Light Inverter is operational. Single Blink-Green Light Double Blink-Green Light Inverter is not being used. Shore power is applied to load. Inverter will Activate when shore power is unavailable. Inverter is on in the Load Demand mode and is waiting for AC load to be turned ON. Inverter Fault LED Light Action Description Red Light Unit shutdown* Check the inverter's front panel LEDs for reason of shutdown: Low Battery, Overload, or Overtemp. *Refer to the Troubleshooting section of this manual for fault diagnostic information. Charger LED Light Action Description Blinking Green Light Steady Green Light AC (shore/utility power) is present and battery charger is in the High Charge (Bulk) mode. AC (shore/utility power) is present and the battery charger is in the Maintenance (Float) mode. Charge Fault LED Light Action Description Red Light Unit shutdown* Check the inverter's front panel LEDs for reason of shutdown: Low Battery, Overload, or Overtemp. *Refer to the Troubleshooting section of this manual for fault diagnostic information. 9

Section 6: Operating the 20-1050CUL Inverter/Charger Use the following instructions to operate the 20-1050CUL Inverter. Step 1: Install the 20-1050CUL unit. Completely install the inverter and charger using the instructions provided in Section 2 of this manual. Step 2: Start the vehicle. Turn the Battery Disconnect Switch on and start the vehicle. NOTE Throughout this manual, shore/utility power is referred to as AC input power. Step 3: Turn switches on. Turn on the Module Disconnect Switch and the Inverter Remote Switch. Step 4: Apply shore power to the 20-1050CUL/Ambulance shore line connection. After shore power has been connected one of the Charger LEDs will light or flash. Push the ON-OFF/RESET Inverter Switch to the ON position. The inverter lamp will flash, indicating that the inverter is standing by. Step 5: Verify Power. Apply an AC load, such as a shop light or drill. The AC load is run directly from shore/ utility power. Step 6: Observe the inverter operation. Remove the shore line connection from the emergency vehicle. The unit will automatically switch to Inverter mode and operate the AC load using battery power. When shore power is restored, the unit examines the AC inp ut for five seconds and then switches the loads back to run directly from AC/shore power. With the ON-OFF/RESET Switch in the ON position, a double flash of the ON light indicates the load demand is turned ON and the load is less than 5 Watts. 10

Section 7: Troubleshooting the 20-1050CUL The following are the most common questions heard by Vanner service professionals. If your situation does not apply to the following categories, please contact your local Vanner Incorporated Service Center. Vanner Incorporated Customer Service: 1-800-AC-POWER SYMPTOM SOLUTION SYMPTOM SOLUTION SYMPTOM SOLUTION SYMPTOM SOLUTION The LEDs on the front panel blink in sequence. It is normal for this to occure if the inverter switch is On when the DC input is connected to the unit. If the DC is already connected and the LEDs blink in sequence then the DC input is dipping in voltage. Check for poor connections in the DC wiring, bad battery, or a heavy DC load. ON lamp does not light steadily after pushing in the ON-OFF/RESET Inverter Switch. Lamp flashes when utility power is present. Lamp flashes in Load Demand Waiting mode. Check/Reset GFCI on the receptacle.** Check battery connections if utility power is OFF. Check DC fuses if utility power is OFF. ON lamp fully illuminates. AC load does not run. Check and reset circuit breaker and GFCI receptacle**. Verify AC load and cord are in proper condition. BATTERY LOW lamp illuminates when AC load is applied. Check battery connections. Check battery condition. Recharge battery if voltage is less than 10.5 VDC. Check the vehicle's alternator charging system for proper operation. SYMPTOM SOLUTION SYMPTOM SOLUTION OVERTEMP lamp illuminates. Something has caused the unit to overheat. Check for obstruction of air flow to the cooling fan or from ventilation holes. Verify AC load is within unit s rated capacity. OVERLOAD lamp illuminates with AC load applied. Verify AC load is within unit s rated surge and continuous capacity. SYMPTOM SOLUTION DC fuse blows when connecting DC input cables. Check for reverse polarity: red cable to battery positive (+), black cable to battery negative (-). The unit may be damaged and require repair service. **Note: If GFCI trips and the inverter is in load demand mode the GFCI may not reset until you toggle inverter off and back on and then you will have 5 seconds to reset GFCI before unit goes back into load demand again or you can disable load demand via dipswitch, if available. 11

Section 8: GFCI Test Record For maximum protection against electrical shock hazard, operate the Test Switch on the Ground Fault Circuit Interrupter at least once a month. ENTER YEAR JAN FEB MAR APR MAY JUNE JULY AUG SEPT OCT NOV DEC 20_ 12

Limited Warranty 1. Vanner Inc., warrants that this product is free from defects in materials and workmanship for a period of one (1) year from its date of shipment from Vanner's factory. 2. This warranty does not cover defects caused by misuse, neglect, accident, reversed polarity, unauthorized repairs, and/or replacements. 3. All warranties of merchantability and fitness for a particular purpose; written or oral, express or implied, shall extend only for a period of one (1) year. There are no other warranties which extend beyond those described on the face of this warranty. 4. Vanner does not undertake responsibility to any purchaser of its product for any undertaking, representation, or warranty made by any dealers or distributors selling its products beyond herein expressed. 5. Vanner does not assume responsibility for incidental or consequential damages, including, but not limited to responsibility for loss of use of this product, loss of time, inconvenience, expense for telephone calls, shipping expense, loss or damage to property, or loss of revenue. 6. Vanner reserves the right to repair, replace, or allow credit for any material returned under this warranty. Any damage caused by the customer will be charged or deducted from the allowance. 7. All warranty work will be performed at Vanner's factory, or authorized repair facility. Products shall be delivered to Vanner's facility, freight prepaid. Products repaired under warranty, or replacement parts or products will be returned, F.O.B. Vanner factory. Vanner Inc. 4282 Reynolds Drive Hilliard, Ohio 43026 Tel (614) 771-2718 Fax (614) 771-4904 www.vanner.com Specifications Subject to Change Copyright 1996, Vanner Inc. Printed in the USA OM/A96283 REV B 8/2016 13