Refinery Supply Company, Inc.

Similar documents
Deadweight Testers and Gauges Instruction Manual

Refinery Supply Company, Inc.

2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Air-Assist Service Jack Max. Capacity: 10 Tons

Service Jack. Form No Parts List & Operating Instructions 1510B. Max. Capacity: 5 and 10 Tons. 1 of 3. Sheet No. Issue Date: Rev.

Under Axle Jack Max. Capacity: 25 Tons

Installation and Operation Manual

B21 Series BASOTROL Gas Valve

HYDRAULIC BODY REPAIR KIT

P5510. Users Manual. Pneumatic Comparison Test Pump

AXD 530 MicroManometer

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

VEGETABLE OIL DISPOSAL UNIT (MSDU) OPERATOR & SERVICE MANUAL

Installation Manual DIAPHRAGM WELL TANK

COMPRESSED AIR LOADER MODEL: AL-1

Air / Hydraulic Under Axle Jack

Standard Service / Installation / Operation Manual Type W & P Water / Glycol Heat Transfer Coils

VESTIL MANUFACTURING CORP. OPERATION & SERVICE MANUAL PORTABLE DRUM JACK (DRUM-55-S) 2999 NORTH WAYNE STREET, P.O. BOX 507, ANGOLA, IN 46703

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

FIXED DEPTH INSERTION METER INSTRUCTIONS

P5510. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Racing Jack Max. Capacity: 3,000 lbs. (1,361 kg)

Full View Flow Indicator

INSTRUCTIONS Refillable, reusable. Extra versatile. Pressurized by free air

Hydraulic Gear Puller Instruction Manual

Portable Two-Stage Under Axle Jack Max. Capacity: First Stage: 27.5 Tons Second Stage: 11 Tons. Safety Precautions

Owner s Manual & Safety Instructions

Hand Held Pull Tester Instruction Manual Order No

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

#9040 FUEL TANK SWEEPER

Battery Powered Hydraulic Pump; Kit PN [ ]

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

SERIES OPERATION AND MAINTENANCE MANUAL

Valtek Flow Boosters

TactAir 4-Stage PCP Hand Pump. Operation Manual

Ford Meter Box Test Bench Installation Instructions

MODEL G300 BRAKE BLEEDER

Table of Contents WARRANTY

Shortening Disposal Unit

OPERATING INSTRUCTIONS

Porta-Punch Manual

DeZURIK 2 20" BOS BUTTERFLY VALVES

Valtek Spring Cylinder Linear Actuators

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Hydraulic Immediate Need Power Pack

Tuffy Liquid Level Controls with Pneumatic Switch

Megohmmeter Test Probe

Purging Air From Divider Block Lubrication Systems

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MODEL 611x SERIES Sliding Gate Barriers Hydraulic Pumping Unit (HPU)

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

Air / Hydraulic Pump

Hydraulic Transmission Jacks

Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

Fuel Tank Sweeper #9049 OPERATOR S MANUAL

Crispin Valves Operating Guide. Crispin

(SDU 50, SDU 90, and BKSDU) Shortening Disposal Unit * * Installation, Operation, Service, and Parts Manual

Hydraulic Transmission Jack, Telescopic

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

D Instructions/Parts. Siphon Feed Detail Spray Gun D

User s Guide. TQ513 Series Rotating Torque Sensors Shaft-to-Shaft Configuration. Shop online at omega.com

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

INSTRUCTIONS DURA SHOT S SPRAYERS DIRECTIONS FOR OPERATING DURA SHOT S. 24 oz. DURA SURE SHOT S SPRAYER.

HIGH LIFT HYDRAULIC TRANSMISSION JACK K12110

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Manual Operated Floor Jack

Enclosed Electric Rotary Screw Compressor Installation Guide

BOLT TENSIONERS. carefully before use and retain it for reference.

Model 88F Twincone Magnet Wire Stripper

Operators Manual. Recirculating Chiller /06/08

MODEL NO & UP SAFETY INSTRUCTIONS. Keep this Operator s Manual in the plastic tube behind the operator seat.

MODEL 900 IMPELLER-TYPE FLOW METER

3000 SERIES DRY-BLOCK HEAT SOURCE

Air Hydraulic Rivet Tool

INSTALLATION AND OPERATION MANUAL Low Profile Long Frame Floor Jack Model: RFJ-3000LPF REV B

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

CSA products for waste water. Combination air valve. Mod. SCF 2

15,000kg HYDRAULIC BOTTLE JACK

Operating Instructions & Repair Parts List

Operation and Maintenance Instructions Manual BOOSTER. Volume amplifier

Specialty Pond Sprayer

GB910 GAGE BILT MADE IN U.S.A. HYDRAULIC POWERUNIT

Mini Jacks Instruction Manual

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

SD Bendix E-12 & E-15 Dual Brake Valve DESCRIPTION

Installation, Operation, and Maintenance Manual

Hydraulic PTO Flow Device

Techcon Systems TS5000 Series Rotary Valve

Owner s Manual GLASSLINED PUMP TANK

Transcription:

Refinery Supply Company, Inc. OPERATING INSTRUCTIONS Super Pressure Dead Weight Tester Catalog No. 35260 Serving the Oil & Gas Industry since 1923 9133-A East 46th Street Tulsa, Oklahoma 74145-4823 Voice (918) 621-1700 Fax (918) 621-1704 www.refinerysupply.com 1

Table of Contents General Information Page 3 Principles of Measurement Page 3 Accuracy of Tester Page 3 Section I. Section II. Start Up Unpacking the Dead Weight Tester... Page 4 Where to Find Help... Page 4 Tools/Equipment Requirements.. Page 4 Safety Procedures.. Page 5 Setting Up and Operating a Dead Weight Tester... Page 6 Procedure for Calibrating a Gage. Page 6 Using a Tester as a Deadweight Gage Page 7 Operating Instructions Procedure for Calibrating a Dead Weight Gage.. Page 8 Adjusting Test Gages Page 8 Preparing an Instrument for Transport.. Page 8 Section III. Maintenance Tools Required Page 9 Maintenance and Service Page 9 Certification Procedures Page 10 Oil Changes Page 10 Maintenance Schedule Page 10 Product Warranty Page 11 Section IV. Troubleshooting Page 12, 13 Section V. Replacement Parts Page 14 Section VI. Schematics Page 15 Section VII. Return Authorization Repair Form Page 16 2

GENERAL INFORMATION Dead Weight Testers are a source of very accurate pressures and are used for calibration of other less accurate types of pressure measuring devices, such as bourdon tube pressure gauges. The high accuracy is obtained by balancing the force exerted by the oil pressure on a piston of known area against weights of known mass. The weights and piston are calibrated in sets to give an accuracy of 1/10 of 1% which is 10 PSI at 10,000 PSI indicated pressure. The portable Super Pressure Dead Weight Tester consists of a piston and table, weights, pressure pump, and gauge connector, all mounted on bases and enclosed in a convenient carrying case, and one carrying case with extra weights. Various connecting adapters and tools for working on gauges are enclosed. PRINCIPLES OF MEASUREMENT The most accurate instrument available for measurement of pressures above the range where manometers may be used is the Refinery Supply Dead Weight Tester. This type of tester operates on the principle of balancing a known mass against the force exerted by an unknown pressure on a piston of a known area. ACCURACY OF TESTER A Certificate of Calibration accompanies every new instrument, verifying that its accuracy is 1/10th of 1% of the rated pressure. A Certification traceable to NIST standards can be supplied when a 0.02% accuracy is required. ACCURACY OF REFINERY SUPPLY DEAD WEIGHT INSTRUMENTS A. All Refinery Supply Dead Weight Instruments are calibrated with traceability to a National Institute of Standards and Technology (NIST). Pressure standards are referenced on the certificate supplied with the instrument. B. The instrument calibrations performed for temperature are based on Standard Gravity 980.665 cm/sec². The temperature and pressure Coefficients are found on the certification sheet supplied with each Dead weight instrument. C. If accuracy greater than 0.05% is desired, a Certificate of Calibration is furnished. If the actual psi values on the certificate are used, the instrument will have an accuracy of 0.05% or better. Reference the equations for correcting for the effects of temperature, pressure, buoyancy and elevation. 3

SECTION I. START UP UNPACKING THE DEAD WEIGHT TESTER The Refinery Supply Dead Weight Tester or Gage and its accessories were tested and inspected before the unit was shipped from our warehouse. Carefully inspect the instrument and its accessories. If the unit is received in a damaged condition, immediately notify Refinery Supply and file a claim with the carrier. WHERE TO FIND HELP In the event of problems, the sales representative will be able to help or the personnel at Refinery Supply can be contacted. Telephone number: (918) 621 1700 Toll free number: 866 836 4729 Fax number: (918) 621 1704 E mail address: Jason@refinerysupply.com Website: www.refinerysupply.com TOOLS/EQUIPMENT REQUIRED High pressure tubing (must be rated for use at the maximum pressure of the instrument) Suitable high pressure fittings or adapter fittings (must be rated for use at the maximum pressure of the instrument) Adjustable wrench or suitable open end wrench A supply of proper oil (recommend 10W Non detergent motor oil) 4

SAFETY PROCEDURES Read and observe the following precautions: Always wear safety glasses when operating dead weight instruments. A high pressure oil leak can cause permanent eye damage. Do not attempt to operate the instrument in excess of the maximum pressure noted on the instrument. NO SMOKING signs should be displayed in laboratories and laboratory doorways whenever testers are being used for instrument calibration. Because a leak in the tester s high pressure line can release an explosive mist of oil, proper fire extinguishers should be immediately available. Pre load the tester s piston with weights before applying pressure to the gage. Otherwise, shock from the pressure can dislodge the piston retainer ring, allowing the piston to fly out of the tester at high velocity. The operator could be seriously injured if standing directly over the instrument. Spinning the table counterclockwise and failing to load the table with weights before introducing pressure into the instrument can cause the table to spin off on some models, and the pressure nut to blow off, allowing the piston to become a dangerous projectile. When a tester is used to test a gas or liquid line pressure, connecting tubing and fittings should be rated at a pressure that is higher than the line pressure. Before bleeding pressure from the tester, the valve at the pressure source should be closed. The instrument s pressure should then be slowly bled to atmosphere. If a vent valve in unavailable, the fitting at the tester should be carefully and slowly loosened. This procedure is to create a small leak, minimizing the volume of oil that will enter the interconnecting tubing. CAUTION!!!!!! Hydraulic Fluid, such as Shock absorber, brake fluid, or transmission fluid may not be substituted for the hydraulic oil specified for the instrument. Only approved oils are to be used as tester oils. We recommend 10W Non detergent motor oil or any light weight machine oil. 5

SETTING UP and OPERATING a DEAD WEIGHT TESTER Procedure for Calibrating a Gage 1) Position instrument on the table. The weight table of the Dead Weight Tester must be level and stable before a gauge is calibrated with the tester. A level is mounted on the tester s base plate for leveling the instrument. 2) Remove the carrying case cover, weight rods, and weights from the tester s base. 3) Fill reservoir with recommended oil. 4) Connect the gauge to be calibrated to the tester, using one of the adapters supplied with the tester. 5) Apply pressure. Close the suction line valve, open the discharge valve, and use the hand operated oil pump to generate pressure applied to both the piston and the gauge being calibrated. 6) Float the table. When the table, while loaded with appropriate weights, floats while being rotated, the known pressure is being applied to the gage being calibrated, and its indication or dial can be observed. Note: Maintain pressure by keeping the guide rod positioned between the two scribe marks on the guide rod, increasing or decreasing pressure as necessary 7) If the reading of the gauge being calibrated is in error, the gauge can be adjusted while pressure is still applied from the tester. 6

Using a Tester as a Dead Weight Gage When an unknown pressure is to be measured by a tester, the tester s chamber is filled with oil, and the unknown pressure is applied through a valve and a tube or hose and then through the connector that is mounted on the testers base. The Dead Weight Tester measures applied pressures using the same principle as the Dead Weight Gage. The only differences are the parts that comprise the pressure chambers. In either configuration, the external pressure is applied to the bottom of the piston and is balanced by the mass of the weights that are added to the table. 1) When an unknown pressure is to be measured by a tester, the tester s chamber is filled with oil, and the unknown pressure is applied through a valve and a tube or hose and then through the connector that is mounted on the tester s base. 2) To move oil from the reservoir into the chamber, the discharge line valve is closed, and suction line valve is opened. The pump handle is turned counterclockwise to pull oil into the pump. Then, the suction line valve is closed, and discharge line valve is opened. 3) Turn the pump handle clockwise to force the oil out of the pump and into the pressure chamber. 4) To transfer another pump load of oil, the discharge line valve is closed, the suction line valve opened, and the process is repeated. 5) When using the Tester to measure unknown pressure, both valves should be closed. 6) After the unknown pressure has been measured by the tester, the oil is returned to the reservoir by reversing this procedure. 7

SECTION II.-OPERATING INSTRUCTIONS Procedure for Calibrating a Dead Weight Gage: The weight table of the Dead Weight Tester must be level and stable before a gage is calibrated with the tester (or if the tester is used as a gage to determine an unknown pressure). A level is mounted on the tester s base plate for leveling the instrument. In the field, a tripod provides a stable support for the device. After the carrying case cover, weight rods, and weights are removed from the tester s base, the gage to be calibrated is connected to the tester, using one of the adapters supplied with the tester. When the gauge is connected to the tester, the gage becomes part of the tester s pressure chamber. To apply pressure, the suction line valve closed, the discharge valve opened, and the oil pump is hand operated to generate pressure applied to both the piston and the gage being calibrated. When the piston, loaded with appropriate weights, floats while being rotated, the known pressure is being applied to the gage being calibrated, and its indication or dial can be observed. If the reading of the gage being calibrated is in error, the gage can be adjusted while pressure is still applied from the tester. Adjusting Test Gages Calibration of this type of instrument will normally consist of removing the pointer from its shaft and then reattaching it to the shaft at the proper indication. Two tools are furnished with the tester to aid in this corrective procedure. One is a hand jack that assists in removal of the pointer from its shaft. The other is a pointer driver that can be used as a drift punch to tap the pointer back onto its shaft without damage to the gage. Both accessories are attached to the base of a new tester. We recommend you store them after their use, using the mounting screws that are provided in the tester s base. Preparing an Instrument for Transport After the test gage has been calibrated, the oil in the tester s piston should be pumped back onto the tester s reservoir and the test gage removed from the tester. Then the weights, weight rods, and tester cover are replaced, preparing the instrument for the next job. 8

SECTION III. - MAINTENANCE Tools Required Adjustable wrench or suitable open end wrenches Maintenance and Service To ensure accuracy of Refinery Supply Dead Weight Instruments: 1) Transport the instrument with cover in place. If the cover becomes damaged, it should be replaced. 2) Firmly tighten the knurled nut of the weight rod before transporting to avoid abrasion of the weights and loss of their mass. 3) If the weights are abraded in transport or are damaged by being dropped, they should be replaced. 4) Clean the weights with a soft brush rather than with a coarse or soiled cloth to avoid altering the mass of the weights. 5) Avoid contaminating the instrument with dust and grit, preventing unnecessary wear of moving parts. Contamination of the oil in the system will accelerate piston and cylinder wear and degrade instrument accuracy. 6) Fill the oil reservoir through the filler cap with light weight non detergent motor oil BEFORE an instrument is used for the first time. The oil level must be maintained above the lower end of the cylinder, or the gas will bypass the oil. Maximum sensitivity of the instrument to pressure requires that the oil be light at the time of measurement. 7) For the instrument to be sensitive, the metal to metal interface of its piston and cylinder assembly is designed to allow for the minor escape of oil past the piston to minimize friction and lubricate the piston. Therefore, some leakage past the piston is normal and necessary. A moderate escape of oil can be controlled by adding heavier oil. Excessive leakage or blowing of oil past the piston indicates excessive wear of the piston and cylinder assembly and requires replacement of the assembly. The piston and cylinder assembly can be replaced without need of factory calibration if the model and serial number of the dead weight instrument is supplied. 8) Replace hydraulic oil (do not use transmission fluid, brake fluid, or shock absorber) in the reservoir with recommended 10W Non detergent motor oil when the test fluid or gas (oxygen) will be reactive with the hydraulic oil. Before use with oxygen, clean and purge the system, and replace all seals. 9) Ensure that high pressure fittings on the dead weights instruments are tight when operating the instrument indoors. 10) Remove the piston and cylinder for cleaning by unscrewing the adapter nut. If the nut is sealed to the body with an O ring, it should only be finger tight when replaced. 9

CERTIFICATION PROCEDURES: The Refinery Supply Dead Weight Tester or Gage is a precision device that will require periodic re certification due to wear of the piston area and weights. To re certify the dead weight instrument, ship to 9133 A East 46th Street Tulsa, Oklahoma 74145 along with Dead Weight Tester Repair Form supplied with these instructions. We will repair any damaged components and perform a cross float with our Master Dead Weight Instrument that is NIST certified. Once completed, an up dated certificate is issued. OIL CHANGES: Replace the oil if any contamination is suspected. Corrosive contaminants in the oil may damage the piston and cylinder assembly. SUGGESTED MAINTENANCE SCHEDULE: Inspect condition & safety of instrument: Change oil: Re certify: After each use Every 6 months or as necessary Every 12 months (or as needed) 10

REFINERY SUPPLY COMPANY, INC. 9133 A EAST 46TH STREET TULSA, OKLAHOMA 74145 PRODUCT WARRANTY REFINERY SUPPLY CO. INC. shall warranty its products to be free of material and workmanship defects for a period of one year from shipping date. Refinery Supply liability for defective equipment shall be limited to the repair or replacement of said equipment without charge to the customer. REFINERY SUPPLY CO. INC. will be liable only if the defect is reported immediately. REFINERY SUPPLY CO. INC must give written permission for any product under warranty to be returned for repair or replacement. The warranty will be null and void if the equipment was subject to altercation, misuse, neglect, modification, and improper installation or repaired by unauthorized persons not approved by Refinery Supply Co. REFINERY SUPPLY CO. INC. will not be liable for expenses, loss or damages, damages directly or indirectly arising from use of the products or for any liability from their use either separately or in combination with other equipment, material or any other cause. Voice (918) 621-1700 Fax (918) 621-1704 www.refinerysupply.com 11

SECTION IV. TROUBLESHOOTING PROBLEM Gas escapes past piston when used to determine unknown gas pressure. SOLUTION A) Insufficient oil in reservoir adapter Shut off and bleed pressure from tester. Pump oil to adapter until reservoir is full. B) Damaged Cylinder O ring Unscrew cap nut. Remove guide rod and piston. Use wrench to unscrew cylinder adapter. Replace O ring. Damaged adapter O ring Gas bubbles or blows into oil of center reservoir when determining unknown gas pressure. Unscrew cap nut. Remove guide rod and piston. Use wrench to unscrew cylinder adapter. Replace O ring. Not sensitive to small weight changes when used to determine unknown gas pressure. A) Over tightened cylinder cap nut Unscrew cap nut. Re tighten only until snug. B) Dirty Oil Remove oil. Clean reservoir with solvent. Fill reservoir with clean oil. C) Damaged Piston Remove piston & cylinder as per above Damaged O ring Clean with solvent. If Binding is evident, replace with new Piston & Cylinder assembly. Pressure cannot be maintained when calibrating another pressure gage. A) Air is drawn into pump because of insufficient oil in center reservoir Unscrew cap and check oil level in reservoir. Add oil if necessary. B) Damaged cylinder adapter O ring Unscrew cap nut. Remove guide rod and piston. Use wrench to unscrew cylinder adapter. Replace O ring. C) Leakage through valve 12

SECTION IV. TROUBLESHOOTING PROBLEM Excessive oil leakage at piston. SOLUTION A) Damaged cylinder O ring Replace o ring. B) Oil too light Check and remove fluid in reservoir if it is transmission fluid, brake fluid, or shock absorber. Replace with recommended 10W Non detergent motor oil. C) Worn piston & cylinder assembly Replace with new Piston & Cylinder assembly Not sensitive and/or inaccurate operation during hydrostatic testing. Water emulsifying with tester oil Best = Use synthetic oil instead of standard mineral oil. Satisfactory = Use oil water separator. 13

PARTS LIST FOR 35260 DEAD WEIGHT TESTER Catalog Number Description N13000 Needle valve 1/8 male N16001 Bushing 1/2 x 1/4 N16011 Female connection, steel 1/8 N16012 Compression fitting, brass 1/8 N27001 O-ring, piston N27002 O-ring N27038 U-cup N29000 Pump handle N35000 Spirit level N35001 Handle, carrying case N60018 Hand Jack N60026 Weight,.1 PSI N60027 Weight,.2 PSI N60028 Weight,.5 PSI N60029 Weight, low pressure 1 PSI N60030 Weight low pressure 2 PSI N60031 Weight, low pressure 5 PSI N60033 Weight, low pressure 10 PSI N60034 Weight, low pressure 20 PSI N60035 Weight, low pressure 100 PSI N60036 Weight, low pressure 500 PSI N60037 Weight boss N60051 Stand off for 7 carrying case N60071 Base plate for weights 7 N60074 Base plate for tester N60089 Pump plunger, brass N60092 Reservoir cover N63007 Weight rod N63010 Pointer driver N63011 Oil pump cap N63012 Filler plug N63013 1/4 male x 1/4 female adapter N63014 1/4 male x 1/8 female adapter N63015 1/2 reservoir adapter N65025 Cover, carrying case N67030 Piston & Cylinder assembly N76500 Nut, knurled N93050 Oil, dead weight tester 8 oz. 14

'. 0::,_ IJJ (/),_ IJJ,_ :I: <w!> 3: 0 <X IJJ 0 II 15

PLEASE FILL OUT THIS FORM AND RETURN IT WITH TESTER WHEN YOU SEND IT IN FOR REPAIRS AND/OR RECERTIFICATION. COMPANY NAME BILLING ADDRESS PURCHASE ORDER NUMBER SHIP TO ADDRESS (INCLUDING PHYSICAL LOCATION FOR UPS SHIPMENTS) REASON FOR RETURN OF UNIT: RECERTIFICATION REPAIR DESCRIPTION OF ANY MALFUNCTION OF UNIT IS NIST CERTIFICATION REQUIRED ON THIS UNIT? YES NO NAME OF PERSON RETURNING UNIT PHONE NUMBER SERIAL NUMBER Refinery Supply Company, Inc. 9133-A East 46th Street Tulsa, Oklahoma 74145 Voice (918) 621-1700 Fax (918) 621-1704 www.refinerysupply.com 16