Customer Owned Copper Outside Plant Guidelines

Similar documents
Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

OSP Fiber Optic Cable

Caledonian Fire Resistant Optic Fiber Cables

Powershift. Take back the power with the industry s first intelligient plug-and-play dc power supply.

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877

VITALink Taped Splice Pigtail Crimp

PATCHMAX GS3, GS6 and PowerSUM Modular Panels

Power & Control Cable IEC

Outlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors.

UNSHIELDED MULTI CONDUCTOR

Mining and Petrochemical Tray-Rated Fiber Optic Cables

Interconnect Cable Simplex and Duplex

Power & Control Cables. U o. /U 0.6/1 kv - IEC

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

E R C. R E R C ; ; W T E C

TC-RHH/RHW-2 USE-2 Copper

Generator Fire Safety: Generator assemblies should be located outside the building.

Power & Control Cables

C A Heating Cable Gland Kit Installation Instructions

Installing Power Components

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

fiber optic cable Outdoor Cables

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Laser Optimized Multimode

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

NEC 2011 Code Changes

Fiber Splice Panel Rack Mount User Manual

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Application Specification. Optical Fiber. Aramid Yarns. 2mm Subunit Jacket. Strength Rods. Outer Jacket

Power & Control Cable IEC

WRSS Wraparound Repair Sleeve Installation Instructions

Medium Voltage Power Cables

UNP-U-Type Universal Panel Instructions

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

OPTICAL FIBER CLOSURE

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

2001 PRODUCT CA T ALOG

Power & Control Cable IEC

Section 02: Pre-Installation Procedures

ezprep Gel-Free Loose Tube Gel-Free Loose Tube Cable (2.5mm)

FOSC-400A4 INSTALLATION INSTRUCTION

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

High Voltage Copper, Smooth Aluminum Shield/Sheath

HITRONIC HQN Single-mode & Multi-mode Glass Optical Fiber Cable for Outdoor Applications

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Telephone Cables Fire Warning Cables

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Product Bulletin. Be Certain with Belden. Belden DataTwist 1200 Cables

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

NEC 2014 Code Changes

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

Mini-Span ADSS Cable

CRANE, CONVEYOR, LIFT & REELING CABLES

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

MC or MV-105 Copper, TR-XLPE Insulated

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Electronic Instrumentation

12-Inch Hybrid Fiber Access Terminal Installation Instructions

Bulletin Wiring methods for Solar Photovoltaic Systems Rules and , Tables 11 and 19

Bulletin Wiring methods for Solar Photovoltaic Systems Rule and , Tables 11 and 19

ezspan ADSS All-dielectric self-supporting loose tube cable

TEK Brief July Is there a difference in installation requirements between communications cables with and without the LP designation?

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

CS Fiber Optic Splice Case. Instruction

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Fiber optic splice closure

P R O D U C T C AT A L O G T ALOG

User Manual. Solar Charge Controller 3KW

3000SC Fiber Optic Splice Closure

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Detailed Specifications & Technical Data

TIDALFLUX 2300 F Quick Start

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Outside Plant All Dielectric

LCD Annunciator Installation Instructions

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Variable Frequency Drive (VFD) Cable Solutions

ELB ELB

ThermoLite 110W-330W Solar Panel Installation Instructions

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

Transcription:

Customer Owned Copper Outside Plant Guidelines December 2017

Introduction CommScope offers several products to extend high performance copper connectivity to the outdoor environment where cabling may be exposed to sunlight, high humidity, condensation and wet locations. In many cases surge protection from electrical hazards may also be needed. The most common applications requiring this infrastructure support are security cameras and wireless access points. Several standards and code documents would be important to apply at these installations. In the United States, most campus installations would be guided by NFPA 70 National Electrical Code and local adoptions for the parts of the installation within buildings, and IEEE National Electrical Safety Code (NESC) for outdoor installation including aerial and underground requirements. NFPA 780 Standard for the Installation of Lightning Protection Systems may also be referenced. It should also be recognized that outdoor installations can present a wide range of hazards to installers and occupants. and so, measures and procedures for safety must be established. NESC Part 4 outlines Work Rules, many of which apply to communications installation. There are also a wide range of ICC, NFPA, IEEE, TIA, ISO, ANSI, ASTM, RUS, Telcordia, USDA and NEMA, documents providing additional regulations, requirements, specifications and recommendations. Local authorities having jurisdiction over construction and contracting should be consulted on specific safety and code requirements as well as general recommendations. The following documents provide useful guidance for low voltage outside plant installations: TIA-758-B Customer-Owned Outside Plant Telecommunications Infrastructure Standard TIA-607-C Generic Telecommunications Bonding and Grounding (Earthing) for Customer Premises BICSI Telecommunications Distribution Methods Manual BICSI Outside Plant Design Reference Manual Applications equipment manufacturers may have additional requirements and should be consulted for their equipment cabling and protection guidelines. 2 Customer Owned Copper Outside Plant Guidelines

Products Outside Plant (OSP) cables are designed and qualified differently than Inside Plant (ISP) cables. The following cables are: Gel filled and suitable for routing through water exposed and flooded pathways, including direct burial Suitable for aerial, building attached, underground and direct burial Suitable in direct sunlight over an extended temperature range; -40 C to +70 C (-40 F to +158 F) - Installation temperature range is limited between -30 C to +70 C (-22 F to +158 F) They can be terminated on conventional indoor outlets and panels and on high performance surge protectors where protection from electrical exposure is also needed, but the ends should be blocked with sealant to minimize leakage of the gel flooding compound. These cables are not listed for indoor placement so designs must ensure that all local codes are followed. Typical requirements include minimizing the distance that these cables are routed through the indoor environment. Note: the 1572A and 1592A gel fill lowers the NVP and the delay has been de-rated by 6% so maximum permanent link length is reduced from 295 feet to 277 feet. CommScope also offers a similar Category 5e F/UTP Low Smoke Zero Halogen cable, 5ENS4ZH. This cable is not filled and has a more restricted temperature range -20 C to +60 C (-4 F to +140 F). It is suitable for water and sunlight exposure, but not suitable for underground or buried. The following Indoor/Outdoor rated modular cords are also available. MATERIAL ID CO11152-01 CO15542-01 CO11192-01 CO15582-01 DESCRIPTION PCOSP-6S-BK (Category 6 F/UTP) PCOSP-6U-BK (Category 6 U/UTP) PCOSP-6AS-BK (Category 6A F/UTP) PCOSP-6AU-BK (Category 6A U/UTP) PRODUCT CODE DESCRIPTION MATERIAL ID 5NF4 Category 5e U/UTP 4286104/10 6NF4+ Category 6 U/UTP 4665904/10 TE620OSP Category 6 U/UTP 2171028-1 1571 Category 6 U/UTP 760008888 1572A Category 6 F/UTP 760170886 1592A Category 6A F/UTP 760178129 These OSP cables are used in designing categorized solutions up to 100 meters. They are all small and light cables and maximum installation and operating tension must be limited to 111 N (25 lbf). Aerial installations require a messenger line and lashing. They may be directly buried, although underground is preferred for physical protection. These cords are suitable for pole and building mounted applications with exposure to sunlight and water, but the end plugs must be protected inside the application equipment or a sealed enclosure (NEMA4 or IP 66 rated). They are also CM and LSZH listed and have an IEC 332-1 rating, and can be routed indoor in locations suitable for CM cables and where halogen materials are prohibited. They have the more restricted temperature range -20 C to +60 C (-4 F to +140 F), and are not suitable for buried or underground locations. 1 & 2 Port Power Over Ethernet Extenders are available and can be mounted with outdoor cameras, access points and other Ethernet powered devices at cabling distances as far as 3000 meters. This application uses Powered Fiber Cable, a hybrid type with 2, 4 or 12 OM3 or OS2 fibers and either 12 or 16 AWG power conductors. Powered Fiber Cable is available with Outdoor Rated polyethylene jacket or Indoor/Outdoor Rated (riser/lszh). Designed for long underground cable pulls, the maximum installation tension is 440 N (98.92 lbf). Operating tension is 132 N (29.67 lbf). Also, suitable for building attached and aerial with lashing to a messenger. Installation temperature range is -10 to 60 C with an operating temperature range of -40 to 70 C. Customer Owned Copper Outside Plant Guidelines 3

Solutions When planning Outside Plant designs, temperature extremes should be considered. The filled cables are rated to extended temperatures, but other cabling products are more limited. Installation below lower temperature specifications can cause jacket cracking, although operational limits can be lower. Many areas such as northern Arizona can be exposed to high temperature extremes, especially over rooftop or in other confined sun exposed locations. For extreme locations, some application equipment is available with cover shields to minimize the solar loading, but designers should also consider solar exposure on cable routing and placement. ANSI/TIA-568-C.2 has an informative Annex G showing maximum length derating calculations for cable installation in higher temperature environments. These calculations can be extrapolated up to 70 C, but it should also be proportional to the exposed length. A common application is extension to a second building. ISP Cables OSP Cable (Aerial, Underground or Buried) Wall mounted CAT6-LAN Protector Grounding is dependent on site construction and the electrical system Other application examples are pole and building mounted equipment. Equipment grounding is an important part of ensuring reliable system performance. Depending on distance and pathway, local codes may also require electrical protection. Primary surge protectors and suitable grounding may also be specified and supplied by the application equipment manufacturers but is available from several independent suppliers such as: http://www.itwlinx.com/ http://www.diteksurgeprotection.com/ https://www.erico.com/erico.asp http://www.harger.com Protectors for rooftop equipment can also be roof mounted but must be positioned close to and bonded directly to grounded structural metal Not all building attached cameras and access points require protection, but rooftop and parapet mounting requires it. OSP Cable or Cord Grounded Protectors Pole-mounted DTK-110RJC6APOE Camera Protector 1592A Cable OSP Cord & Ground NEMA Box Ground 4 Customer Owned Copper Outside Plant Guidelines

Another option especially suited for extended distance is the use of the Power Over ethernet Extender. Refer to www.commscope.com/product-catalog/networking-systems/product/powered-fiber-cable-systems/. These units are connected to the equipment room through Powered Fiber Cable that is driven by a 48V SELV source. Local power is not needed at the endpoint and protection is built into the equipment at both ends. Use CommScope s Powered Fiber Distance and Voltage Calculator at www.commscope.com/resources to calculate support distance based on design details. Switch equipment and NEC Class II 48V DC Power Supply OSP Cords & Ground Access Point and Camera 2-Port POE Extender Powered Fiber Cable Ground Customer Owned Copper Outside Plant Guidelines 5

CABLE AND CORD HANDLING In outside environments, avoid contamination or damage to plugs. Plugs must be protected from sunlight and water in a suitable equipment housing or NEMA 4 rated box. Also, avoid exposure to water at cut ends of unfilled cables and cords. Flip the plug anti-snag to make it easier to push through the Heyco cordgrips (flip it back before plugging in) https://www.heyco.com/liquid_tight_cordgrips/ product.cfm?product=liquid-tight-cordgrips- Pre-Assembled Use a split grommet For pulling cords into long pipes a 3/8 sock fits the end plug http://www.lsdinc.com/installation/7314/fish-tailz---#item Lock with a low profile tie http://www.cobraties.com/low-profile-ties.html Coat the Grommet with silicone grease to aid in sealing (avoid getting grease on the plug) The Indoor/Outdoor cords can be routed outdoors above ground and indoors, and can be ordered in lengths long enough for direct (home-run) installations from switch to end equipment. Cords have 20% Insertion Loss De-rating so only 85 meters total can be supported. Extended lengths can be cut in two for terminating the indoor ends at protectors or panels. Terminations are similar to typical 4-pair indoor cables. When handling long lengths ensure that cords are paid out properly ½ OSP cord direct from camera to rack termination Un-reel the long lengths of cordage to avoid twisting or tangling The Outdoor rating is useful when outer wall penetration positions cannot be done at the application equipment. 6 Customer Owned Copper Outside Plant Guidelines

The 5ENS4ZH cable is terminated the same as typical 4-pair indoor cables, but the other cables are gel filled and the termination involves cleaning the excess gel and blocking the end with silicone sealant to prevent future leakage. A typical Blocking Method uses a 2 cm length of Alpha Wire PVC-105-2 tubing or equivalent: http://www.alphawire.com/zh-cn/products/tubingaccessories/fit-wire-management/tubing/pvc1052 Position the filled tube to overlap the end of the inner jacket and seal the gel Fill all space inside the tubing with B-sealant (700010911) Clean off all excess sealant Tape can be used to stabilize the tube for immediate termination before the sealant sets The 1572A and 1592A cables are shielded and the shield must be properly terminated, either grounded or isolated. For exposed installations requiring protection, the end of the shield can be bonded in various ways. Lengthwise slit helps avoid tearing the foil shield https://www.jokari.de/ Pull the jacket back along the slit and remove Fold the foil and drain wire back to work on the inner jacket Prepare the inner jacket for BLOCKING the gel and direct burial Cut back the inner jacket Trim the flute Clean the excess gel The flute can be cut longer to match the blocking tube length Fill all space inside the tubing with B-sealant (700010911) Position the filled tube to overlap the end of the inner jacket and seal the gel Customer Owned Copper Outside Plant Guidelines 7

Fold the drain wire and foil back over the tube and positon the foil to be folded back over the tube An extra piece of foil can be used to cover the foil seam For an HGS620 termination, wrap the drain wire at least two times around and position it where the spring clips will capture them Tape over the foil for stability SYSTIMAX An alternative method is to use the ground lug and B-bond clip that are available in the 12A1 Grounding Kit. Fold the foil back over the jacket end and wrap the drain wire around the end and push the ground lug over the wrap Open the B-bonding clip to be placed and closed over the grounding lug The lug tail can be cut off or used for ground attachment Treat the inner jacket as above For an isolated shield termination, the 1572A and 1592A outer jacket foil and drain wire are removed a short distance back from the termination and electrical tape is used to isolate the foil end 8 Customer Owned Copper Outside Plant Guidelines

A protector can provide the transition to indoor cable, but the gel filled outdoor cable types will still need blocking. ITW Linx CAT6-LAN Protector http://www.itwlinx.com/products/surgegate-modular-communication-protectors/cat6-lan Verify hole diameter blocking may need to remain outside the cover Maintain pair twists up to termination points Avoid having pairs crossing into each other If surge protection is not needed, Gel flooded U/UTP cables can also be blocked and transitioned to indoor cable using a Ceiling Connector: http://www.commscope.com/catalog/cable_assemblies/product_details.aspx?id=46345&sayt=1 Terminate the indoor cable first then lay down a bed of B sealant Clean all gel from the end of the OSP cable After the OSP cable and conductors are positioned, fill the area around the cable end with sealant and close the connector housing Customer Owned Copper Outside Plant Guidelines 9

Powered Fiber Cable is a hybrid flat cable with a loose tube fiber bundle and power conductors on each side. The jacket is designed to easily split the power conductors away from the fiber bundle so they can be separately terminated. Minimum bend radius to protect the fiber performance is 5 cm. For the overall cable, bending should only be done in the flat direction, but the separated fiber can bend in all directions. The separated power conductors have no bending restrictions. Long cable pulls can be aided by cable lubricant, but verify the correct type for the jacket material. 3 Section Jacket American Polywater provides various pulling lubricants as well as conduit sealants http://www.polywater.com/ Stranded Power Conductor Polarity ID Corners Coated Fiber Water Blocking Aramid Yarn The power conductors are separated from the fiber by pulling them away The fiber section must be held straight (minimum 5 cm radius) Account for adequate fiber slack Some of the POE Extenders rely on the sealing grommet and power conductor terminations At the equipment rack end, the power conductors are routed to a 48V controlled power source and the fibers to a termination panel Others have a power conductor clamp for holding the cable 10 Customer Owned Copper Outside Plant Guidelines

APPLICATION EXAMPLE: Pole mounted category 6A protector for protecting remote equipment Back Panel http://www.alliedmoulded.com/catalog/ industrial-enclosures-and-accessories/ nonmetallic-enclosure-accessories/backpanels-fiberglass/pf108/ NEMA 4x Enclosure http://www.alliedmoulded.com/catalog/ industrial-enclosures-and-accessories/ nonmetallic-enclosures/10x8-to-14x12- fiberglass-jic-enclosures/am1084h/ Ditek 110RJC6APOE Protector http://www.diteksurgeprotection.com/products/2-networkprotection/62-dtk-110rjc6apoe.html Ground Buss http://www. diteksurgeprotection. com/products/17- accessories/25-100-640.html BR GR OR BR/W GR/W OR/W BL/W OR GR GROUND BR GR OR BR/W GR/W OR/W BL OR/W GR/W BL/W OR GR INPUT Maintain pair twists Bottom Mounted Liquid Tight Cordgrips https://www.heyco.com/ Liquid_Tight_Cordgrips/ product.cfm?product=liquid- Tight-Cordgrips-Pre- Assembled&section=Liquid_ Tight_Cordgrips Bottom Mounted Liquid Tight Bushing https://www.heyco.com/hole_plugs/ product.cfm?product=snap-in-liquid-tight- Bushings&section=Hole_Plugs Minimize drain wire length Tie wrap to hold foil 1592A Cable http://www.commscope.com/catalog/cables/product_ details.aspx?id=4382 Enclosure should be mounted close to the protected equipment Pole Mount Kit http://www.alliedmoulded.com/catalog/ industrial-enclosures-and-accessories/ nonmetallic-enclosure-accessories/polemount-kits/ampolemnt8/ Minimize excess cord length Customer Owned Copper Outside Plant Guidelines 11

CommScope (NASDAQ: COMM) helps design, build and manage wired and wireless networks around the world. As a communications infrastructure leader, we shape the always-on networks of tomorrow. For more than 40 years, our global team of greater than 20,000 employees, innovators and technologists has empowered customers in all regions of the world to anticipate what s next and push the boundaries of what s possible. Discover more at commscope.com commscope.com Visit our website or contact your local CommScope representative for more information. 2017 CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. CommScope is committed to the highest standards, of business integrity and environmental sustainability with a number of CommScope s facilities across the globe certified in accordance with international standards including ISO 9001, TL 9000, and ISO 14001. Further information regarding CommScope s commitment can be found at www.commscope.com/about-us/corporate-responsibility-and-sustainability. CO-112386-EN (12/17)