Meinzer II TM. Testing Sieve Shaker

Similar documents
3. Operating instructions: Minor 200

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

The Powermatic User Guide Test Sieve Shaker

Operating Instructions. Heavy Duty Sieve Shaker. "analysette 18"

Hand Held Pull Tester Instruction Manual Order No

Sieve Shaker 200mm/300mm - 8/12 inch SV003

ML4330 SIEVE SHAKER MANUAL

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

MALCOM Table-Top Digital Viscometer Model PC-1TL Series

USER S MANUAL & WARRANTY INFORMATION

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

KidWalk KidWalk II Dynamic Mobility System

Hydro-Sync Slide-Out System

USER MANUAL Edition

OWNER S MANUAL & WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

Apollo Tilt Wheelchair 18" and 20" Instruction Manual

FlexChem Model 404 Rotating Oven

Spotlight 1,000,000 Power Series Cordless Rechargeable

Sanandres. Tri-Walker. OWNERS HANDBOOK. Product Code: WA02017

Serial N... MX1 Chain Driven Pipe Cutting and Bevelling Machine Parts and Operating Manual

Bio Lion Table Top Centrifuge XC-L5

OLYMPIAN MODEL 740 Operation and Service Manual

Vibratory Sieve Shaker AS 300 control

LC I LIPPERT COMPONENTS HYDRAULIC FULL WALL SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Model 700 Microarray Oven

1 2 3a 3b THREADING CARD 9 10 ABC Office

Feed material Measuring range* Sieving motion Max. batch / feed capacity powders, bulk materials, suspensions 25 µm mm throwing motion with angu

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

Maintenance Adjustments

Operating Instructions. High Energy Vibratory Finishing Bowl. Model FSV-25/50. Vibra Finish Company

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Evo. Suspension Rollator. OWNERS HANDBOOK. Product Code: WA01056

Uplift Power Seat Users Guide

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

9 VOLT ALKALINE. not included

Bio Lion Table Top Centrifuge XC-H165

3000 SERIES DRY-BLOCK HEAT SOURCE

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

CORDED CORDLESS RECHARGEABLE

How to Keep your Treadmill Running

Lumina 28 Traction Drive Model: Battery Burnisher M28036TDQP OPERATION SERVICE PARTS CARE

GRSM17 Pneumatic Center Punch Tool Owner s Manual and Operating Instructions

Embedded Rack Slide-out System

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

Operating Manual. Translation of the original FRITSCH HEAVY DUTY SIEVE SHAKER

OPERATIONS MANUAL LEVER CHAIN HOIST

SwayPro. NOTE: A minimum tongue weight of 200 lbs. is required THANK YOU

Model 2300DL Installation Guide

Tri-Wheel Wheeled Walker

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Wheel Horse. 36 Tiller. Model No & Up. Operator s Manual

OWNER S MANUAL. Model: FSUTV-45-12V ( ) (45 Gallon Lawn & Garden UTV Sprayer, Boom Ready) Technical Specifications. Assembly Instructions

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

ELECTROMAGNETIC VIBRATORY FEEDER INSTRUCTION AND MAINTENANCE MANUAL

Prime Engineering GRANSTAND II

Operator s Manual Portable Wood Chip Moisture Tester ENGLISH

Hydraulic Truck Jack

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

USER MANUAL PRODUCT CODE: WC CareCo (UK) Ltd, Hubert Road, Brentwood, Essex, CM14 4JE PAGE 1

JUMP&GO. Portable Jump Start & Power Supply OWNER S MANUAL

Hydraulic Transmission Jack, Telescopic

Fiber Optic Illuminator. Model 21AC Model 21DC

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Model 2300JL Installation Guide

Keep your area safe with the easiest system you ll ever use. INSTRUCTION MANUAL

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

ELECTRIC BEDROOM SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL


Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

OPERATING MANUAL. Gilson Porta-Screen PS-3 & PS-4

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Speed Cart Vl User s Guide

BRF 700 Fan Bike. * This item is for consumer use only and it is not meant for commercial use.

COOKSON OWNER'S MANUAL

Have a Bright Day! Nicholas Harmon President and CEO

190/195 Tilt Shower Commode User Manual

Required Tools: Phillips screw driver to remove original soft top. Torx sockets are required to completely remove the original soft top hardware.

Hydraulic Long Jacks

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

Centrifuge Operator / Service Manual

Aluminium 4-Wheeled Rollator/ Occassional Transport Chair VP184 Range Usage and Maintenance Instructions

expandable booster Instruction Manual US Version

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

Hawk Enterprises of Elkhart THE BRUTE Owner s Manual

atient lifters Assembly, Maintenance & Specifications Manual SUNRISE HML400 Hoyer Manual Patient Lift HPL400 Hoyer Power Patient Lift Sunrise Medical

Designed around your life

SERIES 600 PAIRED PANELS PARTITIONS

Hybex Microsample Incubator

Garaventa Genesis OPAL

Giant Cone Display Case

Installation Instructions

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

Go Yonder D-Lite Owner s Manual

ARC 1850 LIST OF FIGURES

MOVING HEAD. User manual CAUTION!

Alternating Current Revolution per minute Protective Earth Ground. Protected from dripping water Fuse Attention, Consult Accompanying Document

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

Timer. TipTop Timers. Installation and Operation Manual

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

Transcription:

Meinzer II TM Testing Sieve Shaker Operation & Set-up Manual Model: 18480100 CSC Scientific, Inc. 2799-C Merrilee Drive Fairfax, VA 22031 USA Telephone: (703) 876-4030 (800) 621-4778 Fax: 703-280-5142 E Mail: meinzerii@cscscientific.com Web Site: www.cscscientific.com A Product of the United States of America

Introduction Thank you for selecting this high-quality piece of testing apparatus. We appreciate your support and pledge to assist you in the service of your CSC Scientific testing apparatus. The Meinzer II is a maintenance free, lightweight and portable vibrating shaker that will provide precise, repeatable results time after time. By utilizing an electromagnetic drive, fixed amplitude and rubber spring mounts, this unit produces the simultaneous vertical and horizontal movement needed for basic dry particle sizing analysis. This unit is ideal for use with aggregates, cements, chemicals, powdered metals, cosmetics, grains, seeds, coal, soils, pharmaceuticals, tobacco, coffee and many other dry components in ground, granular of powder form. Each unit is burned in and run continuously for over half a day, guaranteeing performance right out of the box. This unit is not recommended for wet sieving operation. Besides the physical nuts and bolts, this device is backed by a company with decades of experience in the dedicated service of users in the powder and particulate industries. We look forward to servicing you as well.

Specifications Model Designations and Power Requirements Model 18480100....... 110VAC/60Hz operation. Accepts 8"(203.2mm), 200mm or 3" (76.2mm) diameter sieves Timer 1 60 minutes with automatic shut-off, or continuous run setting Dimensional Specifications Unit base............ 10" (25.4cm) diameter x 5.59" (14.2cm), plus Clamp Plate 1.18" (3cm) Weight 37 lbs (17Kg) General Specifications Durable, powder coated finish Unit Capacity.......... 8" (203.2mm) or 200mm - 8 full height or 15 half height, plus pan and cover Unit ships with Operation and Set-up Manual 6' (2 meter) Power Cable Top Plate Assembly Meinzer II Shaker fitted with Clamping Straps and Buckles Sieves, pans and covers must be ordered separately.

Installation & Set-up Instructions The Meinzer II Testing Sieve Shaker is designed to provide years of trouble-free service. To assure that the device delivers optimum performance, several points must be observed before putting the device into service. 1) Installation Position the machine on a level, sturdy surface to ensure the even distribution of the sample over the sieves during operation. 2) Electrical Connections Verify that the voltage and frequency on the Rating Label at the rear of the shaker corresponds with the electrical power supply being used. If any discrepancy occurs, please consult your supplier or contact CSC Scientific Tech Support for assistance. Do not connect any power supply other than that stated on the Rating Label. Important! This equipment must be grounded. When the power is properly connected, the red rocker switch will illuminate when switched to the on position. If the switch does not light, the connector may not be fully inserted or the fuse may be blown. Replacement fuses must be of identical rating. 3) Process Timer The Meinzer II features a mechanical, 1 60 minute timer with automatic shutoff. There is also a continuous running time feature. For settings of less than 15 minutes, rotate the knob past the 15 minute mark and then back to the desired setting. Operating periods are increased by rotating clockwise and decreased by rotating counter-clockwise. The timer will commence timing down as soon as the knob is released, regardless of an electrical connection. When the knob is turned counter-clockwise from the OFF position to the continuous running mark, l, the shaker will continue running until the knob is manually returned to the OFF position. 4) Maintenance The Meinzer II Sieve Shaker is maintenance free aside from keeping surfaces clean. Simply wipe with a soft damp cloth using a solution of warm water and a mild liquid detergent. Do not clean your sieve shaker or sieves with solvents. 6) General Advice The Meinzer II Sieve Shaker is constructed and factory tested to ensure correct operation when connected to the specific electrical supply indicated on the

Rating Label of the machine. Under typical usage, no lubrication or resetting is required. Use of unapproved parts or any alteration to the machine voids the warranty. For replacement parts, please contact CSC Scientific s Tech Support Team at 800.621.4778 or meinzerii@cscscientific.com. Please have your serial number ready for prompt service. CSC Scientific does not accept any responsibility if the operating instructions contained in this manual are not strictly followed.

Performing a Sieve Analysis using the Meinzer II Testing Sieve Shaker TM 1) Complete set up of the Meinzer II Testing Sieve Shaker per instructions under Installation and Set-Up Instructions. 2) Plug the device into the proper power source (be sure that voltage and cycle requirements are observed). 3) Prepare the material sample to be tested using industry-specified sampling and preparation procedures. 4) Select the sieves for the analysis. 5) Assemble the sieve stack, (coarsest sieve at the top, finest at the bottom) with bottom pan. An extended rim pan may be inserted within the stack to run multiple samples. See Figure 7 A in the FAQ s for an example of the extended rim pan. Bear in mind the overall height of the sieve stack may not exceed the capacities shown in Chart 4A of the FAQ s. 6) Pour the sample to be tested onto the top sieve. Install a standard sieve cover to prevent sample loss. 7)Place the sieve stack on the Bottom Plate. 8) Cover the completed stack with the Top Plate and secure as follows: Raise the Clamping Latch Lever upwards to expose the Latch Hook. While holding the Clamping Latch with one hand, press the lever on the Cam Buckle with the other. Slide the Cam Buckle along the Strap until it can be engaged into the Clamping Latch hook. Release the Cam Buckle and pull the loose end of the Strap downwards to partially tension. Do not over tension! The Clamping Latch lever will remain in the raised position, 20 30 degrees from the vertical when partially tensioned. Repeat these steps on the other side. Press both levers down, closing the Clamping Latches to secure the stack. Do not use excessive force. It may be necessary to loosen the straps slightly to secure. Repeat the previous action to

release or increase the tension in the strap as necessary to ensure a firm grip. Warning: Do not run the machine with unsecured sieves. 9) Set the timer for the desired test interval. For timer setting instructions please refer to item three in the Installation & Set-up Instructions at the front of this manual. 10) Once the test is complete, allow the sieve stack to come to a stop. 11) Remove the sieve stack and proceed to weigh-up the retained fractions. Warning: Do not attempt to release the Clamping Latches and remove the sieves while the machine is still running.

Table 1

Table 2

Table 3

Table 4

Table 5

Table 6

Table 7

CSC Scientific 2799-C Merrilee Dr. Fairfax, VA 22031 USA Toll Free: 800.621.4778 Tel: 703.876.4030 Fax: 703.280.5142 www.cscscientific.com meinzerii@cscscientific.com TM Meinzer II Frequently Asked Questions 1. What are the vibrations per minute for the Meinzer II? A 60Hz machine will produce 3,600 vibrations per minute. 2. What sort of maintenance is required for the Meinzer II? The Meinzer II just needs to be kept clean. No lubrication or resetting of parts is required. Any alteration or unauthorized maintenance will void the warranty. 3. Can test sieves for the Meinzer II be calibrated/certified? Yes. Please contact our Customer Service Team at 800.621.4778 or meinzerii@cscscientific.com. 4. How many sieves can fit in on the Meinzer II? Please refer to Chart 4A for details on the Meinzer II sieve capacity. Chart 4A Meinzer II Sieve Capacity Half Height Full Height Pan Cover (min/max) (min/max) 8 (203.2mm)or 200mm 4/15 2/8 1 1 5. My Meinzer II is making a lot of noise and the sieve stack is rattling in the machine. What is wrong? The sieve stack may have been improperly secured. Failing to fully clamp as in Figure 5A or adequately tighten the straps as in Figure 5B will cause the sieve stack to rattle. For instructions on how to properly build and secure your test sieve stack, please refer to step 8 in Performing a Sieve Analysis using the Meinzer II Testing Sieve Shaker in the front of this manual. Figure 5A Figure 5B

6. What is the warranty on the Meinzer II? The Meinzer II carries a one year limited warranty against defective material and workmanship. 7. What is an extended rim pan? Do I need this for my test? An extended rim pan is manufactured with a skirt around the bottom so it can be received by a sieve below it. This will allow the user to run multiple samples in one stack. The extended rim pan can be inserted mid-stack to collect fines of sample one and the bottom pan will collect fines from sample two. See Figure 7A for an example. Figure 7A 8. The fuse has blown in the machine. How do I change it? The fuse must be replaced with one of identical rating. To replace the fuse, perform the following: Disconnect the machine from the power supply. Unscrew the central cap of the fuse holder. Remove the holder and fuse. Remove the blown fuse from the fuse holder and place the new fuse in the metal spring in the central cap. Fit the cap and fuse back into the holder and screw in completely. Do not over tighten. 9. Does CSC Scientific have a repair facility nearby? CSC Scientific is pleased to offer telephone repair support for Meinzer II Testing Sieve Shakers. Contact a member of our Tech Support Team at 800.621.4778. Alternatively, machines may be sent in to our location in Fairfax, VA for extensive repair or refurbishing. Contact us for information on how to prepare your machine for receipt and service by our Repair Department. 10. My questions have still not been answered. For further technical support, please contact our Tech Support Team at 800.621.4778 or at meinzerii@cscscientific.com. We d be glad to assist.

Notes: