BRACKETS, MOUNTS & HARDWARE

Similar documents
3.0OVERHEAD TRANSMISSION SWITCHES

Catalog 14A January 2013

TYPE BLT DISCONNECT SWITCHES

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

HUBBELL Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Three-Phase Pole Mounted Recloser

OVERHEAD DISTRIBUTION SWITCHES

GROUNDING & BONDING PRODUCTS

Disconnect & ByPass Switches

M-Force three-phase switch

Jumpers & Load Pickup Tools

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents

SECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS

Product Specifications for Phase Over Phase GOABS(r)

Technical Specification for Pole Mounted Capacitor Rack

PART NUMBER POLE DIAMETER RANGE CARTON QTY " to 5" " to 6 3 4" " to 7 3 4" " to 8 3 4" 10

JUMPERS & SWITCHING TOOLS

M-Force three-phase switch

D-73P disconnect and bypass switches

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

Switchgear Skid, C1192

CENTRE FEED UNIT UP TO 4000A. Safety

PRODUCT NAME ORDER # PAGE # ANTENNAS

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

SECTION 8 - SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS

Kuhlman Electric Corporation Volt Instrument Transformers

Item Code Description Unit Qty Total

CRITO Connection technology. Double and triple T and TCC section busbars

MEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

Steel Fabrications Equipment Brackets

600 A 15 and 25 kv class Cleer grounding elbow

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

Copper Bar... ASTM B187, B152 Silicon Bronze... ASTM F468, F467, F651

OVERHEAD DISTRIBUTION SWITCHES

25 kv Apparatus Bushings

CON EDISON EQUIPMENT

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

For mounting. cutouts, power fuses, arresters, capacitors, terminations, conduit EQUIPMENT MOUNTS

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Product Specifications for Aluminum Vertical Break Switches

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

TERMINATION ENCLOSURE OPTIONS

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

GROUP D. Switch & Protective device.

When power interruptions happen.

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Honeywell Salisbury Outage Protection. Bushing Covers, Conductor Covers, Instant Insulation

Distribution Arresters

SMP Series. High Amperage Connectors. Rated to 1135 V AC DC

7 Single Family Service

Index. Aluma Form, ALUMA-FORMEQUIPMENT MOUNTS Inc. WORLD S MOST COMPLETE LINE

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

Cobra-S. Catalog Cobra-S

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

Jumpering and grounding equipment and assemblies

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Continue to use current part numbers, we will help you translate these to new part numbers.

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

RUS accepted Catalog O-vst18

R49 SERIES TABLE OF CONTENTS

COMMERCIAL QUICK REFERENCE

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

1100 OVERHEAD TRANSFORMERS

POLE MOUNTED CAPACITOR RACKS

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

solutions RUS accepted

GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual

Solid Dielectric, Single Phase Recloser

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

Series 2, 3, 4 Steel Cable Ladder Steel Cable Ladder, Series 2, 3, 4 & 5

High Voltage Cable Accessories Product catalog

Kuhlman Electric Corporation Volt Instrument Transformers

UG FEEDING OH UG FEEDING OH. Electric Distribution Standards I. INTRODUCTION

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Grounding Equipment. Catalog 3000 March Grounding Equipment 3000

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

Series 2, 3, 4, & 5 Steel - Accessories

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

TYPE BILT DISCONNECT SWITCHES

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

MINIMUM DISTRIBUTION SYSTEM CONCEPTS AND APPLICATIONS. Larry Vogt. Manager, Rates

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

Transcription:

HIGH VOLTAGE SWITCHGEAR & AUTOMATION EQUIPMENT SECTION 6 Brackets, Mounts & Misc. Hardware CAT. NO: 040930G May, 2008 INERTIA Engineering & Machine Works, INC. Fax: (209) 931-8186 6665 Hardaway Road, Stockton, CA 95215 e-mail: sales@inertiaworks.com (800) 791-9997

BRACKETS, MOU & HARDWARE Insulator Brackets for Overhead Lines 6.10-6.16 Vault Brackets and Junction Cabinets 6.30-6.33 Substation Flexible Jumpers 6.50-6.51 Miscellaneous Hardware 6.70-6.73 Self-Design Worksheet Last page BRACKETS, MOU & HARDWARE 6.0

Tri-Frame brackets reduce installation time and crossarm replacement. They are available in 15 kv - 69 kv versions with either standard clearances or raptor protection clearances. They are available either with or without insulators. 64" 64" 3/8" ALUM. END PLATES 6.0" ALUM. CHANNEL 3/4"X 1-3/4" GRADE 5 HEX BOLTS AND LOCK WASHERS SUPPLIED WITH 34.5 KV TINNED UNIVERSAL CLAMP TYPE SILICONE INSULATORS. TORQUE INSULATOR MOUNTING BOLTS TO 65-75 FT. LBS. 14" 12" Aluminum 96" 8.0" MAX. FROM TOP OF POLE 48" Triangular Framing Assembly 35 kv Raptor Clearance 11/28/01 9-084A-EXM 0 6.10

Special application insulator mounting brackets. Lightweight, durable; available with or without insulators. 6" 15" 95 kv BIL INSULATOR 4" CHANNEL 20" 9 5 / 8 " 13" 10 5 / 8 " 29" 7 1 / 2 " 13" TANGENT DEAD-END HOLE 13/16" INSULATOR PIN HOLES 5/8" BOLT SLOTS TWO POLE INSULATOR RACK 9-359BM 18" 15" 20" 10 1 / 8 " 18" 95 kv BIL INSULATOR 15" FOUR POLE INSULATOR RACK 9-359AM 20" 16 5 / 8 " 16 5 / 8 " Al or HDG Steel 10 1 / 8 " 95 kv BIL INSULATOR 36 1 / 4 " 10 5 / 8 " THREE POLE INSULATOR RACK 9-359C Pole or Tree Mounted Insulator Brackets 11/03/00 9-359M 13" 13" POLE OR TREE MOUNTED INSULATOR BRACKETS ARE AVAILABLE IN: -A36 HOT DIP GALVANIZED STEEL -6061-T6 ANODIZED ALUMINUM 29" 6.11

Order 10 or 10,000 custom standoff brackets, built to your specifications Ø 13/16" (3X) 4.0" Ø 13/16" (2X) 15 2.0" 15 Ø9/16" 8.0" 4.4" 6.0" 8.0" 3.4" 6.0" 2.0" Ø 13/16" X 1.25" SLOT Ø13/16"X1.25 (2X) 9-342-1M 6" Offset, Line Post Mounting Bracket with 9/16"Arrestor Mounting Hole 5/16" Hot Rolled Steel Hot Dipped Galvanized 2.5" 6.0" WOOD CROSSARM 1.25" 12.0" Ø13/16"X1.25 TOP VIEW SIDE VIEW 5.0" 95.0 9-341M Horizontal Insulator Crossarm Mounting Bracket HDG Steel Miscellaneous Line Post Insulator Brackets 9-342-2M 6" Offset, Line Post Mounting Bracket 5/16" Hot Rolled Steel Hot Dipped Galvanized 4.5" 6061 T-6 ANODIZED ALUMINUM 6.0" END VIEW Ø 13/16" 01/12/00 9-341& 9-342M 0 6.12

Order 10 or 10,000 custom standoff brackets, built to your specifications 8.0" Ø11/16 (2X) Ø13/16 70 1/4 Hot Rolled Steel, Hot Dip Galvanized. 4.0" 2.0" 8.0" Ø11/16 (2X) 2.0" X 20 X 8.0" MOUNTING INSULATOR STANDOFF BRACKET 5,000 LB. VERTICAL LOAD Ø13/16 9-366-1M 9-366-2M 70 Miscellaneous Line Post Insulator Brackets 4.25" 4.25" X 20 X 8.0" MOUNTING INSULATOR STANDOFF BRACKET 2,000 LB. VERTICAL LOAD 1/4 HDG Steel 1/4 Hot Rolled Steel, Hot Dip Galvanized. 01/15/00 9-366M 0 6.13

Twin circuit insulator brackets reduce installation time and crossarm replacement. They are available in 15 kv - 69 kv versions with either standard clearances or raptor protection clearances. They are available either with or without insulators. 58" 3/8"X5"X5" ALUM. 6" 6"X4.49" LB. ALUM. CHANNEL 48" 70" 19" 3/4" BOLTS (3X) 58" 6061-T6 Al POLE Twin Circuit, 34.5 kv Pole Top Insulator Frame FRAME IS SUPPLIED WITH OR WITHOUT INSULATORS. INSULATORS ARE BOLTED UPRIGHT ON THE HORIZONTAL ARMS FOR SHIPPING.. 48" 01/25/00 9-394M 0 6.14

21.38 125.4 19.50 19.1 54.6 9-425-5L 9-425-4L 9-425-1 44.5 9-425-5C 9-425-2 9-425-3B 35.4 9-425-4R 9-425-5R 69 kv 3-Phase Termination Bracket 9-425-2B 60.0 24.877 04/10/03 9-425M 0 6.15

5 5 16 Ø 9 16 30 3 4 5 5 16 Ø10 22 1 16 Ø7 1 2 Ø 9 16 Ø8 3 4 18 5 Ø 11 16 16 25.0 15 1 8 25 3 8 6061-T6 Al Termination Bracket, 69 kv Single Phase 10/21/02 9-420AM 0 6.16

3/16X1 S.S. CLAMP BRACE SIL. BRZ./S.S. HARDWARE JUNCTION BAR 3/4X1/8 S.S. U-BRACKET JUNCTION BAR CUT-AWAY JUNCTION RAIL PROVIDES 3-2 WAY, 3-3 WAY AND 3-4 WAY, 200 AMP AND 600 AMP JUNCTIONS, MOUNTED IN AS SMALL AS A 3 FT. X 5 FT. ENCLOSURES IN A MINIMAL AMOUNT OF TIME. THE STRONG, DURABLE STAINLESS STEEL JUNCTION RACKS ARE AVAILABLE WITH OR WITHOUT JUNCTION BARS. CONSULT THE FACTORY FOR CONFIGURING TO YOUR SPECIFIC REQUIREME. S.S. STOVE BOLT 54.75" SLIDING S.S. PARKING STANDS (6X) 16.5" S.S. CHANNEL S.S. MOUNTING BRACKETS 8.25" 6.75" Ø 0.563" JUNCTION BRACKET ACCOMMIDATES : 3-4 WAY CONFIGURATIONS 3-3 WAY CONFIGURATIONS 3-2 WAY CONFIGURATIONS GROUND LUG 96" GROUNDING BAR FRONT VIEW Stainless Steel 12" GROUND LUG/WIRE CONNECTION POI 72" END VIEW PULL ANGLE 48" Vault Rack/Junction Bar Assemblies 200 A & 600 A 11/28/01 9-085M 0 6.30

25.5" 1/4"X3" ALUM. 9/16"X1.0" SLOTS (3X) MATERIAL: 6061 ALUMINUM FRAME 304 STAINLESS LOADBREAK ELBOW PARKING STANDS STAINLESS STEEL FASTENERS As described 34.0" 20.25" Wall Mounted, 200 A Elbow Parking Stand 07/11/01 9-309M 0 6.31

40 5-1/2" 8" 8" Ø 9/16" 19-3/4" 22-1/2" ALL 300 SERIES STAINLESS STEEL FASTENERS AND COMPONE Elbow Parking Stand, 3-Position Ø9/16"X11/16" SLOTS (4X) 8-1/4" 05/03/04 9-086M 0 6.32

Ø 13 16 (6X) 3/4X2-3/4 (2X) FLAT WSHRS(4X) LK WSHR (2X) A 44 1 8 9-414-1 W-BEAM CLAMP 9-414-3 (4X) 3 6 6 4 4 1 VIEW-A JACK SCREW 9-414-2T 3/4X2-3/4 (4X) RIGHT SIDE 3" MINIMUM NOTE: 1 1 4 9-414L 9-414R WALL MOU EACH KIT CONTAINS COMPONE FOR TWO ASSEMBLIES AS SHOWN 2"SCHD.80 PIPE (48") 9-414-5 TEMPORARY VAULT SUPPORTS TO BE USED DURING CONCRETE OR BRICK VAULT REPAIRS LOAD RATINGS ARE DEPENDANT UPON VERTICAL PIPE DIAMETER AND LENGTH. 10 10 FLOOR PLATE 9-414-2B Temporary Vault Support Kit 59-72 09/04/03 9-414-OAM 0 6.33

Eliminate bushing fatigue and failures caused by rigid conductors or corroded, once flexible, conductors with custom super-flexible jumpers. Use our stainless steel shear-nuts with the jumpers to make repeatable and reliable electrical connections to electrical equipment. 1 KA PADS ARE 2 HOLE NEMA 2 KA,3 KA AND 4 KA ARE 4-HOLE NEMA OR 6-HOLE NEMA PADS PER CUSTOMER SPECIFICATIONS TINNED COPPER SUPER-FLEX, ROPE LAY, TINNED COPPER CONDUCTOR TINNED COPPER SUPER-FLEX, ROPE LAY, TINNED COPPER CONDUCTOR (3-10 FEET) SPECIFY LENGTH IN ONE FOOT INCREME 2 KA AND 3 KA JUMPERS ARE SUPPLIED WITH CONDUCTOR SPACERS 90 DEGREE 4-HOLE ADAPTER PADS ARE AVAILABLE 5.0" 9-331 5.0" 9-332 EXIST. PAD 3/4"X4" Cu. @ 90 EXIST. PAD SHORT SPAN FLEX BRAID JUMPERS: 1 KA, 2 KA, 3 KA AND 4 KA 1/2" S.S. BOLTS, BELLEVILE WASHERS, FLAT WASHERS AND NUTS AS REQUIRED (1X-4X) 750 MCM Cu. 3" TO 8" RADIUS 9-332-2 28" Tinned Copper EXIST. PAD (4 HOLE NEMA) HORIZONTAL ARMS FOR SHIPPING. 12"-18" Busbar Separation EXIST. PAD (4 HOLE NEMA) (1X-4X) 750 MCM Cu. 9-332-3 20± 2" ALL JUMPERS ARE DESIGNED TO HAVE A MAXIMUM TEMPERATURE RISE OF 33 C AT 25 C AMBIENT TEMPERATURE. CRIMP PAD (4X) 3/4"X4" Cu. @ 90 (2 PLACES) JUMPERS CAN BE SUPPLIED WITH UV STABLE, TRACK RESISTANT INSULATION FOR WILDLIFE PROTECTION. CONSULT FACTORY FOR YOUR SPECIFIC REQUIREME Super-flexible Busbar Jumpers, 1 KA - 4 KA 03/14/00 9-331& 9-332M 0 6.50

Swaged, tinned copper, flexible flat braids are available in customer specified lengths. Terminal pad configuration are available in 150 to 1200 A continuous current ratings. Use Inertia stainless steel shear-nuts with the jumpers to make repeatable and reliable electrical connections to electrical equipment. 1.75" Ø0.563" 3.0".62" 1.0".50" 2.0" 2-3/8" As described 4/0 TINNED COPPER BRAID (2 PIECES) FOR 800 AMP CONTINUOUS TIN PLATED COPPER NEMA PADS Flexible Tinned Copper Braid Jumper, 800 A SPECIFY LENGTH IN 1" INCREME 02/08/01 9-391M 0 6.51

Standoffs- for replacing pin cap insulators with stronger station post insulators and conversion from 5 bolt circle insulators to 3 bolt circle insulators and vice versa. (4)Ø 0.687 HOLES ON 5.00" B.C. AT 90 4.75" Ø 9/16" (4X) 3/8" PLATES A36 H.R.S. HOT DIP GALV. Ø 11/16" (4X) 9-202M 5" BC TO 3" BC INSULATOR STAND-OFF As shown H.D. Galv. 9-348M 5" BC x 4" INSULATOR STAND-OFF Station Post Insulator Adapters, 5 Bolt Circle 10/13/99 9-202 & 9-348M 0 6.70

Lightweight and economical conductor spacers install in seconds and provide long service life. The shedded design provides extended wet creepage distance. The UV resistant, silicone finish provide years of service in the most severe environments. PHASE SPACER FOR SMALL CROSSECTION OVERHEAD CONDUCTOR. LIGHTWEIGHT SOLUTION TO PREVENT PHASES FROM CONTACTING EACH OTHER DURING HIGH WIND CONDITIONS. CONDUCTOR INSTALLATION: 1. SLIDE CONDUCTOR INTO SLOT UNTIL GRIPPED BY CAPTIVATING WIRE CUTOUT. NOTE: SMALL HOLE IS FOR NO. 6 WIRE, LARGE HOLE IS FOR NO. 2 WIRE. 2. GRIP SPRING CLAMP WITH PLIERS AND SLIDE IT UP TO THE CONDUCTOR. SPECIFICATIONS: MATERIAL: DELRIN 527 SILICONE FINISH.001 IN. MIN. TENSILE STRENGTH MIN. AT 100 C: 4.8kpsi ELECTRICAL WET WITHSTAND: 4,500 VOLTS/in. ULTRAVIOLET RESISTANCE: 80% MAX ELONGATION AT 600kj/m^2 COLOR: SKY GRAY WEIGHT: 5.0 OZ. 9/16" DIA. STAINLESS STEEL SPRING CLAMPS 65 kv WET WITHSTAND VOLTAGE, MINIMUM 17-1/2" NO 6 CONDUCTOR 18-1/2" NO. 2 CONDUCTOR DELRIN 527 PHASE SPACER, 5-25 kv, #6 & #2 AWG. 11/27/01 9-151A M 0 6.71

Pole top fuse canisters provide storage for unique or uncommon fuses not routinely carried on service vehicles. Site-specific fuses can be stored on the pole where these fuses are used, making them available when and where they are needed. SLIP ON CAP CAP LANYARD 3/16"X 1-1/2 ALUMINUM 29" Grey PVC/Al 24" MOISTURE WEEP HOLE 1/2" LAG BOLT HOLE MOUNTING Fuse Holder, 24, Pole Mounted FASTENERS 4" DIAMETER PVC PIPE 05/21/99 9-305 M 0 6.72

Stainless steel shear-nuts make repeatable and reliable electrical connections to electrical apparatus. Zinc, die cast shear nuts can be used for lower torque requirements. Installing rod guides, steps and other hardware to fiberglass poles or crossarms can damage the fiberglass pole or crossarm when excessive torque is applied. Shear nuts mitigate this problem. O-RING SHEAR POINT Shear Nut Construction Material Shear Point Size 1/2-13 304 Stainless steel 45-55 lbs 1/2-13 Zinc, Die Cast 25-30 lbs The above sizes are used for field connections to electrical equipment where specific torque values are required to compress Belleville washers and ensure a good electrical connection without the need for torque wrenches and the associated calibration of that tool. Other sizes, materials and torque-limits are available. Consult the factory for your specific needs. As shown Torque-limiting Shear Nut, 1/2-13 0.927 1/2-13 2B 09/11/00 9-399 M 0 6.73

Fax: (209) 931-8186 Rev.