OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

Similar documents
High Voltage Copper, Smooth Aluminum Shield/Sheath

Global data. Electrical parameters

Submarine Power Cables

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

High Voltage and Extra High Voltage Cables

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

XLPE CABLES AND CABLE SYSTEMS KV MODERN SOLUTIONS FOR POWER CABLES/ESTRALIN HVC

Power & Control Cable IEC

Power & Control Cable IEC

Quintas & Quintas Group

XLPE Cable Systems. User s guide. rev. 2

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

Power & Control Cables

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

DURAREEL TRAILING REELING CABLE

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Your Partner in Safe Power Solutions. About RESCAB

First South East European Regional CIGRÉ Conference, Portoroz KV 2 X 1000MW SUBMARINE CABLE CROSSING OF THE DARDANELLES STRAIT IN TURKEY

JDR PRODUCT APPLICATIONS. MCE Deepwater Development 2017

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Power & Control Cable IEC

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3


MEDIUM VOLTAGE POWER CABLES

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

Company Profile. Caledonian Medium Voltage Cables

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

BS6724 SWA/LSZH Cable IEC /1000V

ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor)

ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

MC or MV-105 Copper, TR-XLPE Insulated

TC-RHH/RHW-2 USE-2 Copper

TRATOS OIL&GAS NEK606

I N T R O D U C T I O N

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

flame Retardant overall screened Instrumentation cables (Multicore)

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

EXTRA HIGH VOLTAGE c a b l e s

Medium voltage cables

N2XY IEC XLPE PVC 0.6/1kV Cable

Achievement and experience in service of long length HV DC electrical links by insulated power cables

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM)

BS 6724 Armoured Power Cables, 600/1000V

600/1000V, XLPE Insulated Cables according to IEC

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

power cable accessories

ABB Group August 27, 2010 Slide 1

(K),(M),(P)489TB/G Up to 42 kv

Standardization IEC /-351/-353. Conductor material

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

LIST OF PUBLISHED STANDARDS

Pyrohalon. Cables, halogen-free, fire-retardant. Pyrohalon PLUS Fire-resistant cables, halogen-free, fire-retardant

Hans Kvarme Nexans Norway AS. Offshore vindkraft Oslo, 14. desember 2010

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

THERMOCOUPLE CABLES THERMOELECTRICITY

Power From Shore: An introduction to HVDC Light Offshore

UNSHIELDED MULTI CONDUCTOR

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

PRODUCT NAME ORDER # PAGE # ANTENNAS

Flexible power and control cables

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

ABB Roger Rosenqvist: August 30, 2012

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

Submarine Cable Systems

Airfield Ground Lighting

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

Submarine Cable Systems

Any inquiries, please feel free to contact or Caledonian

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

o o blue-brown Fire Performance BS EN BS EN

Connecting globally. TFCrane

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Cables Connect, cover and forget

The Following Slides are an Overview of the Hanhe Cable products and facilities For full data on G&W and Hanhe Systems, Call us!

600/1000V, PVC Insulated Cables according to IEC

Transcription:

OFFSHORE WIND FEASIBILITY STUDY APPENDICES 10-7 10.3.2 Appendix C.2 Subsea Cable Data Sheets

Design data for TFVA 36 kv 3x1x240 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor Round stranded compressed copper conductor of 37 wires filled with a semiconducting Nominal thickness Diameter over insulation Extruded layer of insulating crosslinked polyethylene (XLPE) Thickness of tape One layer of copper tape overlapped The cores are laid up. Polypropylene yarn fillers and a fiber optic cable are located in the interstices between the cores. Binder tapes are applied over the phases. Thickness Extruded sheath of semiconducting polyethylene One layer of semiconducting nylon tape Shape of armor wires Dimension of armor wires Number of armor wires, approx. Two layers of flat galvanized steel wires applied in opposite direction Two layers of polypropylene yarn and bitumen 18.4 mm 8.0 mm 36.8 mm 0.1 mm 2.0 mm Flat 7.5x2.5 mm 35/37 Outer serving Diameter Diameter of cable, approx. 108 mm Weight Total weight of cable in air, approx. 23 kg/m Total weight of cable in water, approx. 14 kg/m Mechanical data for TFVA 36 kv 3x1x240 mm 2 KQ Bending radius Minimum permissible bending radius during laying 1.9 m Pulling tension Maximum permissible pulling tension 150 kn

Electrical data for TFVA 36 kv 3x1x240 mm 2 KQ Current rating Current rating in seabed 555 A temperature Max. permissible conductor temperature 90 C Ambient conditions Max. ambient temperature for the cable in seabed at burial depth Max. burial depth in seabed Thermal resistivity of seabed 15 C 1.0 m 0.7 K.m/W Metallic s and armor are bonded and earthed at both ends Frequency Frequency 60 Hz Short circuit current Permissible thermal short circuit current in the conductor for 1 second 34 ka Rated voltage Rated RMS system voltage between conductor and metallic /between conductors (U 0 /U) 18/33 kv Operating voltage Normal operating voltage 34.5 kv Highest voltage Highest continuous RMS system voltage (U m ) 36 kv Basic insulation level Lightning impulse withstand voltage (1.2/50 sec.) 170 kv Electrical stress Maximum electrical stress in insulation at highest system voltage U m 3.5 kv/mm resistance Max. DC resistance at 20 C AC resistance at 90 C 0.0754 /km 0.099 /km Cable impedance Cable impedance at 257 A () 0.10 + j0.13 /km Capacitance Capacitance between conductor and 0.24 F/km Charging current Charging current at 34.5 kv 1.8 A/km Loss angle Maximum value at ambient temperature Losses Voltage drop and rated voltage 0.004 Losses at 34.5 kv and 257 A (): - conductor losses - dielectric losses - metallic losses - armor loss Total losses per cable 3x5.4 W/m 3x0.1 W/m 3x0.1 W/m 3.7 W/m 20.5 W/m Voltage drop at, 34.5 kv, 257 A, 60 km and compensation of the charging current at both ends 7.7 % Compensation Compensation of charging current at each end 3.2 MVAr Power 100 % 80 % 12 MW 50 % 7.5 MW 0% 0 MW Max. current 257 A 208 A 137 A 54 A Voltage drop 7.7 % 6.1 % 3.7 % 0.0 % Power losses 1160 kw 740 kw 295 kw 17 kw

Design data for TFVA 36 kv 3x1x800 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor Round stranded compressed copper conductor of 61 wires filled with a semiconducting Nominal thickness Diameter over insulation Extruded layer of insulating crosslinked polyethylene (XLPE) Thickness of tape One layer of copper tape overlapped The cores are laid up. Polypropylene yarn fillers and a fiber optic cable are located in the interstices between the cores. Binder tapes are applied over the phases. Thickness Extruded sheath of semiconducting polyethylene One layer of semiconducting nylon tape Shape of armor wires Dimension of armor wires Number of armor wires, approx. Two layers of flat galvanized steel wires applied in opposite direction Two layers of polypropylene yarn and bitumen 35.0 mm 8.0 mm 54.4 mm 0.1 mm 2.2 mm Flat 7.5x2.5 mm 51/54 Outer serving Diameter Diameter of cable, approx. 149 mm Weight Total weight of cable in air, approx. 48 kg/m Total weight of cable in water, approx. 33 kg/m Mechanical data for TFVA 36 kv 3x1x800 mm 2 KQ Bending radius Minimum permissible bending radius during laying 2.7 m Pulling tension Maximum permissible pulling tension 290 kn

Electrical data for TFVA 36 kv 3x1x800 mm 2 KQ Current rating Current rating in seabed 895 A temperature Max. permissible conductor temperature 90 C Ambient conditions Max. ambient temperature for the cable in seabed at burial depth Max. burial depth in seabed Thermal resistivity of seabed 15 C 1.0 m 0.7 K.m/W Metallic s and armor are bonded and earthed at both ends Frequency Frequency 60 Hz Short circuit current Permissible thermal short circuit current in the conductor for 1 second 114 ka Rated voltage Rated RMS system voltage between conductor and metallic /between conductors (U 0 /U) 18/33 kv Operating voltage Normal operating voltage 34.5 kv Highest voltage Highest continuous RMS system voltage (U m ) 36 kv Basic insulation level Lightning impulse withstand voltage (1.2/50 sec.) 170 kv Electrical stress Maximum electrical stress in insulation at highest system voltage U m 3.1 kv/mm resistance Max. DC resistance at 20 C AC resistance at 90 C 0.0221 /km 0.036 /km Cable impedance Cable impedance at 510 A () 0.055 + j0.11 /km Capacitance Capacitance between conductor and 0.39 F/km Charging current Charging current at 34.5 kv 2.9 A/km Loss angle Maximum value at ambient temperature Losses Voltage drop and rated voltage 0.004 Losses at 34.5 kv and 510 A (): - conductor losses - dielectric losses - metallic losses - armor loss Total losses per cable 3x8.4 W/m 3x0.2 W/m 3x0.6 W/m 15.5 W/m 43.1 W/m Voltage drop at, 34.5 kv, 510 A, 60 km and compensation of the charging current at both ends 8.3 % Compensation Compensation of charging current at each end 5.2 MVAr Power 100 % 80 % 24 MW 50 % 0% 0 MW Max. current 510 A 411 A 266 A 87 A Voltage drop 8.3 % 6.6 % 4.0 % 0.0 % Power losses 2480 kw 1570 kw 620 kw 25 kw