General Information Blower Silencers

Blower Silencers UNIVERSAL. Blower Silencers ENERGY ENVIRONMENTAL

Absorptive Silencers UNIVERSAL. Absorptive Silencers ENERGY ENVIRONMENTAL

Vent/Fan Silencers UNIVERSAL. Vent/Fan Silencers ENERGY ENVIRONMENTAL

LINE SILENCER. Copyright 2009 by PULSCO Incorporated. All rights reserved. Reproduction without permission is prohibited.

NEW PRODUCT SELECTION GUIDE

VENT SILENCER PRODUCT GUIDE

FULL-LINE INDUSTRIAL CATALOG

INTAKE FILTERS and FILTER SILENCERS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Model Model Model

TURBO PRESSURE BLOWERS

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

P a c k a g e s. One step ahead. Energy-efficient Reliable Compact Quiet

Masoneilan * Lo-dB Cartridges and Expansion Plates

Compressor Noise Control

VANEAXIAL & TUBEAXIAL FANS

50 HERTZ METRIC BLOWER

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Mufflers. Absorptive, Reactive, Reactive Lined, Reactive Side Entry, Reactive Side Entry Lined

series RVV Variable flow rate controllers

TURNING AIR INTO SOLUTIONS. AIR KITS. Model FC

Industrial Filters UNIVERSAL. Industrial Filters & Filter/Silencers ENERGY ENVIRONMENTAL

BLOWERS EXHAUSTERS. Positive Displacement blowers (PD), as the name implies, compress CONTINENTAL INDUSTRIE

770 RAM X Roots. Quick Specs. Part Number call RAM X Tri lobe rotary positive displacement blowers

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

EXPANSION JOINT SELECTION GUIDE

Vane Axial Fans Models VAB and VAD. Belt and Direct Drive

Sound Application Guide: Description and Ratings

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Model CBEX Elite HP

Industrial Residential Critical Residential

S UMMARY S PECIFICATIONS. Dresser ROOTS Small Rotary Lobe Positive Displacement Blowers. Operating Principles

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

GE Energy. Roots * EasyAir * X2. Factory blower package system

FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS. by John Michalak Romet International, Inc.

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

TECHNICAL DATA OBSOLETE

CONSTANTFLOW Volume Flow Controllers

Design and Application Details

Inline Fans [ 14 ] * UL is optional and must be specified.

Ford Fabricated Steel Products

Pneumatic Mufflers and Filters. Maximum noise reduction. Maximum Working Pressure 200 PSI. Working Temperature -20 C to 90 C (-4 F to 194 F)

RB-DV 85 High Vacuum Blower

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product

CROSBY STYLE JB PRESSURE RELIEF VALVE

Design and Application Details

Series 769 FireLock NXT Deluge Valve

65 Universal RAI (URAI) PD Blower Visit us online:

BARTON 7400 Precision Gas Turbine Flow Meters

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

SILENCER SELECTION INSTRUCTIONS

Complete HVAC Capability

Installation manual. Exhaust system. Marine engines DI09, DI13, DI16. 02:04 Issue 9.0 en-gb. Scania CV AB 2017, Sweden

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

68 Universal RAI-G PD Blower Visit us online:

University of Delaware

AERZEN BULK VEHICLE BLOWER

Series 756 FireLock Dry System Check Valve

Twin City Fan & Blower

Lateral Access Filter Silencer LQB Series 3 MPT 12 Flange

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS

- METALLIC EXPANSION JOINTS

Custom Shipyard and Military Facility Products

Vertical Pre-Piped Bladder Tanks with Proportioner

SENTINEL VACUUM CONTROLLERS

ABOUT MATTEI CUSTOM BUILT MATTEI COMPRESSOR PACKAGES

Turbo Exhausters and Blowers

PWA-LF LOW FLOW ANSI PROCESS PUMP

59 Universal RAI-DSL PD Blower Visit us online:

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Installation manual. Cooling system. Industrial engines DC09, DC13, DC16 OC16. 01:05 Issue 12 en-gb. Scania CV AB 2018, Sweden

Side channel blowers

ISO 9001 : Dual Plate Wafer Check Valves. API 594 Design API 598 Tested. Maximizing the Flow

Cylindrical Silencers

ARROW INDUSTRIAL PRODUCTS

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

SM Range - a wide range of silencers adapted for all applications :

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Horizontal Pre-Piped Bladder Tanks with Proportioner

FEATURES SELECTION CONSTRUCTION

LESSON Transmission of Power Introduction

Air Moving Solutions. axifan adjustable blade vaneaxial fans

Defining Innovation. backward curved FANs

SIDE CHANNEL BLOWERS

OPERATION MANUAL NT80 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 5/13 rev.2

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

Installation, Operation, and Maintenance Manual

Air Moving Solutions. MODULAR plenum fans

SILENCER SELECTION INSTRUCTIONS

Transcription:

Blower Silencers Technical Literature Inlet Silencers UCI/UCI/UCIA Series age RIS/RIS/RISH Series age Discharge Silencers UCD/UCD Series age URB/URD/URB/URD Series age SD/SD/SDH/SDS Series age RD/RD/RDH/RDS Series age SURS/SURS Series age CBF/CBFI Series age CB Series age UI-BASE Series age 1 1 Accessories Attachment Brackets and Legs age 1 1 Companion Flanges age 1 Inspection Openings and Relief Covers age Universal AET retains the right to update this technical sheet without notice. lease contact your Universal representative to verify the timelines of this technical literature sheet. Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

otes:

In a closed blower discharge system, structure-borne noisesuch as that radiated by pipe wall and silencer shellmay be a consideration, particularly where a stringent, close-proximity noise specification applies. For these applications, various means are available to treat the pipe and shell radiated noise, such that most reasonable specifications may be met. For instance, it is possible to lag the silencer shell externally and reduce any shell noise contribution to below the casing and mechanical noise of the blower and driving machinery. Universal invites your inquiries concerning special applications where EA, OSHA or other noise specifications apply. Special applications are handled on an individual basis and recommendations are made according to specific requirements of the installation. General Information Blower Silencers Rotary ositive Blowers The Rotary ositive Blower is a two impeller compressor that delivers a large quantity of gas or air relative to the individual pulses. Blower capacities are expressed in CFM at inlet conditions (ICFM). Blower size is usually expressed as gear diameter by rotor length. itch Line Velocity (LV) is the peripheral velocity of the timing gearequal to the product of the gear circumference and the rotative speed of the blower, usually expressed in feet per minute (FM). The blower presents two problems: 1) pulsation within the piping system and, ) noise radiation in the vicinity of the blower and piping. The importance of these relative to each other is a function of blower size and speed; both increase proportionately to the blower size and the square of the speed. ulsation is more pronounced on the discharge side. eak pulse pressures are quite severe and can result in unsilenced discharge sound power levels up to 1 1 db. The inlet, although producing less severe pulsation and noise, receives equal attention since the inlet is usually open to atmosphere and the noise much more apparent. Silencers There is little question that silencers are a necessity on any blower installation. Regardless of the size or speed of the blower, silencers of some type are nearly always used. In the selection of blower silencers, there are two basic considerations: 1) the silencer must be the correct size (i.e., sufficient capacity for the volume flow) and, ) the silencer must be the proper type for the application. The nominal silencer size need only be based on the gas volume, (i.e., the CFM of the gas or air at the operating conditions). However, the silencer (design) must be selected with consideration of the blower size and operating speed. Complete application and capacity information is given on page. There are two types of silencers commonly used on positive blowers: a reactive type silencer which consists of a series of expansion chambers having interconnecting tubes, a more sophisticated silencer design. is the combination chamber-absorptive type. This combination silencer is similar to the reactive type with the exception that an acoustically-packed, sound absorbing section is included, comprising an extension of the silencer connection closest to the blower. The inlet of a discharge silencer and the outlet of an inlet silencer are the ends having the packed section. A third basic type of silencerthe simple, straight-through packed typeis occasionally used on blowers. This type of silencer is usually used on small, high speed machines which characteristically produce significant high frequency noise and relatively mild pulsations. The LV is normally the criterion for silencer type selection. If the blower is operating in the critical LV range, it will generate objectionable high frequency noise which may cause shell ring or tank hammer in the piping and silencer. These critical LV conditions will always require a combination chamber-absorptive silencer for satisfactory results. Inlet Silencers For inlet service, a LV of, ft/min or greater is considered critical. This transition speed is empirically established and is somewhat arbitrary, however, it is commonly accepted that blowers operating at or above, ft/min are considered critical for the purpose of inlet silencer application. Those operating below, ft/min are considered subcritical. Subcritical LV applications can usually be silenced adequately with a chambertype silencer, such as Universal URB or UCI Series. Blowers operating above the critical LV of, ft/min will invariably require the RIS Series combination chamber-absorptive type silencer. Inlet Filters or Filter Silencers are commonly used on blower inlets, either individually or in series with a separate inlet silencer. lease reference Filters and Filter Silencers Technical Literature booklet #-1. Discharge Silencers For the more severe discharge conditions of typical blower installations, a LV of, ft/min is accepted as the critical transition speed. Blowers operating below, ft/min are considered subcritical and can usually be adequately silenced on the discharge side by use of a chamber-type silencer UCD or URD Series. Machines operating above the, ft/min transition speed will require combination chamber-absorptive silencers such as SD or RD Series. In some larger blower installations, piping requirements or space restrictions may preclude the use of a large, single discharge silencer such as the SD or RD Series. Where two or more blowers discharge into a common header, individual silencers upstream of the header are required to subdue the individual blower pulsations. Otherwise, the pulsations tend to beat with each other and can be extremely objectionable. ote: Silencers should be mounted as close to the blower as possible since any piping between the blower and silencer will radiate noise. Standard silencer connections are not designed to carry external piping or valve loads, so good piping support practices should be used to prevent stresses that cause fatigue and eventual fracture of the silencer or piping. It is also good practice to isolate the blower from the silencer with a flexible expansion joint. Contact Universal for special design considerations where loading is a factor. Attenuation Curves oise attenuation curves are given for the various models within this catalog. The curves represent insertion loss of airborne noise for typical applications under average conditions. It is not feasible to chart the expected performance of a silencer over a wide range of applications and conditions, therefore, the curves must be used with discretion. Structure-borne noise (see above) may be a consideration and will require separate analysis, since it is not airborne noise and not used for silencer performance rating. Use our online Blower Silencer calculator at. Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

General Information Rotary ositive Blowers The silencers shown below are more fully described on the individual catalog pages. These units are designed specifically for use on Rotary ositive Blowers. There are fundamental similarities between blower silencers and other types, particularly reciprocating engine silencers, which also require a silencer design that provides effective pulse control as well as noise attenuation. However, blower silencers generally must be constructed more ruggedly to withstand prolonged exposure to severe pulsations produced by the blower. All silencers described are of standard with end in, end-out design. Low or high side inlet and outlet connections are available and are described on the individual catalog pages. Accessories, Special Features Mounting Brackets Inspection Openings ressure Vessel Construction Oversize Flanges Special Finishes Special Materials UCI Series Inlet Silencer Chamber-type inlet silencer for use on sub-critical LV applications. Available in pipe sizes " ". Smaller sizes use URB Series. Available with side connections and mounting brackets. RIS Series Inlet Silencer Combustion chamber-absorptive type inlet silencer for critical LV applications. Available in pipe sizes " ". Low or high side outlet and mounting brackets available on most sizes. UCD Series URB/URD Series Discharge Silencers Chamber-type discharge silencer for use on sub-critical LV applications. Available in pipe sizes " ". (Smaller sizes use URB Series). Low, high, or opposed side connections and mounting brackets available. SD Series RD Series Discharge Silencers Combination chamber-absorptive type discharge silencers for critical LV applications. Available in pipe sizes " ". Low, high, or opposed side connections and mounting brackets available on most sizes. Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

Silencer Recommendations As mentioned on page pitch line velocity (LV) is the speed of the timing gear in feet per minute (ft/ min). For purposes of silencer application. LV is considered critical at, ft/min for intake and, ft/min for discharge. Table 1 gives transition speeds in RM. Blowers running at these speeds or greater will have critical LV. Operating speeds below transition will be in the sub-critical range. Blowers operating in the sub-critical speed range usually require only simple chamber-type silencers while those in the critical range require combination chamber-absorptive type silencers. If there is doubt, it is best to use the combination-type silencers. When gear size and operating speeds are known, the proper type silencer is easily selected. Silencer Size Selection, Capacity Table gives the nominal capacity of the various size silencers. Size in this table refers to the silencer nominal size, or its inlet size. Capacities are expressed in inlet CFM (ICFM), thus, discharge silencers are rated at higher capacities than inlet silencers since the air is compressed to reduced volume at the discharge operating pressure. Size 1 1... 1 1 1 Est Temp. Silencer Capacity Inlet Silencer 1 1, 1,,,,,,, 1, 1,,,, F SIG 1 1,,,,,,, 1, 1,,,, 1, F 1 1,,,,,,, 1, 1, 1,,,, 1 F A From Table 1 determine whether blower RM is above or below the transition speed for critical LV. B Consult Table for recommended silencer models. ressure Drop The following formulas may be used to calculate pressure drop through the silencers covered in this catalog. V = c Inlet: (assumes silencer inlet is open to atmosphere) Discharge: V 1. c T = pressure drop through silencer, inches of water V = air velocity through silencer, ft/min* c = individual silencer restriction coefficientempirical constant (see Table ) = discharge pressure, SIA (operating pressure in SIG + 1.) T = discharge temperature, R absolute (operating temperature in F + ) * To calculate velocity through silencer, divide flow in ACFM by cross-sectional area of silencer inlet diameter in square feet. Capacity (Inlet CFM 1. SIA at F) Discharge Silencer SIG SIG SIG 1 SIG 1 1,,,,,,, 1, 1,,,,, 1 F 1 1, 1,,,1,,, 1, 1, 1,,,,, 1 F 1 1 1,1 1,,,,,, 1, 1,,, 1,, 1, F 1 Application, Capacity, ressure Drop Data Blower Silencers Blower Transition Speed Blower Transition Speed-RM Gear Size Inlet Discharge. 1 1 1,,,,1,, 1, 1, 1, 1,,1,,,, 1, 1, 1, 1, 1 Silencer Model Specifications itch Line Velocity Below Transition Above Transition Inlet Silencer UCI, URB RIS Discharge Silencer URB, UCD, URD SD, RD ressure Drop Coefficients Model URB, URB UCI, UCI, UCIH RIS, RIS, RISH UCD, UCD URD, URD, URDH SD, SD, SDH RD, RD, RDH RDS, SDS, URDS ressure Drop Coefficient (C)........ Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

Specifications UCI Group Chamber Type Inlet Silencer Attenuation, db Typical Attenuation Curve 1 Octave Band Center Frequency, Hz ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. The UCI Series Inlet Silencer is a heavy-duty, all welded unit constructed of carbon steel sheet and plate. It provides pulse control and silencing for most subcritical LV applications. Sizes " and larger are equipped with flanged connections drilled to /1 lb ASI specifications. Exterior surfaces receive a shop coat of rust-inhibitive primer and may be finish painted in the field if desired. The UCI Series is the basic inlet model and is the conventional end-in,end-out version. The low side inlet model is designated UCI Series and the high side inlet type is designated UCIH Series. The three types are fundamentally alike and performance is identical. Mounting brackets and other options are availablesee page. UCI Series L H D UCI Series (Low Side Outlet) UCIH Series (High Side Outlet) Drain Chamber Type Inlet Silencers (Size) 1 1... 1 1 1 art umber --AA -1-AA -1-AA --AA --AA --AA --AA --AA --AA --AA --AA --AA D L H 1 1 1 1 1 1...... ote: Dimensions and weights are nominal and may vary slightly with production models. Request certified drawings of specific models for exact dimensions. 1 1 1 1 1 Min Sizes 1" " Use URB Series (page ) 1 1. 1. 1. 1... 1. 1... 1. 1. 1. 1..... UCI Max 1... Min. 1... 1 UCIH Max.. 1.. 1 1 1 Weight 1, 1, 1,,,,, Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. Attenuation, db Typical Attenuation Curve 1 Octave Band Center Frequency, Hz Specifications RIS Group Combination Chamber- Absorptive Type Inlet Silencer The RIS Series Inlet Silencer is a heavy-duty, all welded unit constructed of carbon steel sheet and plate. It features an acoustically-treated outlet and will provide pulse control and silencing suitable for critical LV applications. Sizes " and larger are equipped with flanged connections drilled to /1 lb ASI specifications. Smaller sizes are standard with male threaded pipe nipples. Units sized " and " are available in either flanged or male pipe threads. Exterior surfaces receive a shop coat of rust inhibitive primer and may be finish painted in the field if desired. RIS Series RIS Series (Low Side Outlet) RISH Series (High Side Outlet) E The RIS Series is the basic model, having conventional end-in, end-out configuration. A low side outlet version is designated RIS Series and high side outlet configuration is designated RISH Series. The three types are fundamentally alike and performance is identical. Mounting brackets and other options are availablesee page. L H D Combination Chamber-Absorptive Type Inlet Silencers (Size) 1 1... 1 1 1 art umber --AA --AA --AA -1-AA --AA * --AA * --AA --AA -1-AA -1-AA --AA --AA --AA --AA --AA --AA --AA --AA --AA D L H 1 1... 1 1 1 1 1 1........ 1. 1 1 1 1 1 1 ote: Dimensions and weights are nominal and may vary slightly with production models. Request certified drawings of specific models for exact dimensions. *Specify -TT for male pipe threaded units. RIS.. 1. 1 1.... 1.. 1. RISH 1 1......... E..... 1. 1 1. 1....... RIS Min Max Sizes 1" 1." use U Series (Absorptive Silencers Technical Literature booklet #-1 page ) FIXED AT FIXED AT FIXED AT FIXED AT 1... 1... 1 RISH Min Max." THRU." AVAILABLE O SECIAL ORDER... 1.. 1..... 1 1 1 1 1 Weight 1 1 1, 1, 1,,,,,,1 Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

Specifications UCD Group Chamber Type Discharge Silencer Attenuation, db Typical Attenuation Curve 1 Octave Band Center Frequency, Hz ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. The UCD Series Discharge Silencer is a heavy-duty, all welded unit constructed of carbon steel sheet and plate. It provides pulse control and silencing for subcritical LV applications where the higher performance of the URD Series on page is not warranted. Sizes " and larger are equipped with flanged connections drilled to /1 lb ASI specifications. Exterior surfaces receive a shop coat of rust-inhibitive primer and may be finish painted in the field if desired. The UCD Series is the basic end-in, end-out configuration. A low side inlet version is designated UCD Series. The two types are fundamentally alike and performance characteristics are identical. Mounting brackets and other options are availablesee page. UCD Series L H D UCD Series (Low Side Inlet) Drain Chamber Type Discharge Silencers (Size) art umber D L H Min Max Weight 1 1... 1 1 1 --AA -1-AA -1-AA --AA --AA --AA --AA --AA --AA --AA --AA --AA 1 1 1 1 1 1...... ote: Dimensions and weights are nominal and may vary slightly with production models. Request certified drawings of specific models for exact dimensions. Sizes 1" " use URB Series (page ) 1 1 1 1 1 1 1. 1. 1. 1... 1. 1... 1. 1. 1. 1..... 1... 1, 1, 1,,,,, Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. ote: Sizes 1" " are URB Series; sizes " " are URD Series. Both series are fundamentally the same in design and the performance characteristics are identical. Attenuation, db Typical Attenuation Curve 1 Octave Band Center Frequency, Hz Specifications URB Group URD Group Chamber Type Discharge Silencer The URB/URD Series Discharge Silencer is a heavy-duty, all welded unit constructed of carbon steel sheet and plate. It provides pulse control and silencing for subcritical LV applications. Sizes " and larger are equipped with flanged connections drilled to /1 lb ASI specifications. Smaller sizes are standard with male threaded pipe nipples. Units sized " and " are available in either flanged or male pipe threads. Exterior surfaces receive a shop coat of rust-inhibitive primer and may be finish painted in the field if desired. The URB/URD Series is the basic end-in, end-out configuration. A low side inlet version is designated URB/URD Series; high side inlet is designated URDH Series; and low opposed connection is designated URDS Series. The four types are fundamentally alike and performance characteristics are identical. Mounting brackets and other options are availablesee page. URB, URD Series URB, URD Series (Low Side Inlet) URDH Series (High Side Inlet) URDS Series (Opposed Connections) L H D Chamber Type Discharge Silencers (Size) 1 1... 1 1 1 art umber -1-AA --AA --AA --AA --AA -1-AA --AA * --AA * --AA --AA -1-AA -1-AA --AA --AA --AA --AA --AA --AA --AA --AA --AA D L H. 1 1 1 1 1 1...... 1 1 1 1 1 ote: Dimensions and weights are nominal and may vary slightly with production models. Request certified drawings of specific models for exact dimensions. *Specify -TT for male pipe threaded units. 1 1. 1. 1... 1. 1... URB, URD URDH URDS Min Max Min Max Min Max FIXED AT FIXED AT FIXED AT FIXED AT.. 1 1. 1. 1. 1... 1. 1 1... 1 1 1. 1 1. 1. 1 1. 1.. 1 1. 1. 1. 1... 1 1 1... 1. Weight 1 1 1, 1,,,,,,,1, Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

Specifications SD Group Combination Chamber- Absorptive Type Discharge Silencer Attenuation, db Typical Attenuation Curve 1 Octave Band Center Frequency, Hz ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. Acoustical packing is suitable for F The SD Series Discharge Silencer is a heavy-duty, all welded unit constructed of carbon steel sheet and plate. It will provide excellent pulse control and is equipped with an acoustically-treated inlet for use on critical LV applications. Its pulse and noise performance is recommended for all but the most demanding applications, which may require the RD Series on page. Sizes " and larger are equipped with flanged connections drilled to /1 lb ASI specifications. Smaller sizes are standard with male threaded pipe nipples. Units sized " and " are available in either flanged or male pipe threads. Exterior surfaces receive a shop coat of rust-inhibitive primer and may be finish painted in the field if desired. The SD Series is the basic end-in, end-out configuration. A low side inlet is designated the SD Series; high side inlet, SDH Series; and low opposed connection, SDS Series. The four types are fundamentally alike and performance characteristics are identical. Mounting brackets and other options are availablesee page. L H SD Series D SD Series (Low Side Inlet) SDH Series (High Side Inlet) E SDS Series (Opposed Connection) Drain B Combination Chamber-Absorptive Type Discharge Silencers (Size) 1 1... 1 1 1 art umber --AA --AA --AA -1-AA --AA* --AA* --AA --AA -1-AA -1-AA --AA --AA --AA --AA --AA --AA --AA --AA --AA D 1 1 ote: Dimensions and weights are nominal and may vary slightly with production models. Request certified drawings of specific models for exact dimensions. *Specify -TT for male pipe threaded units. L... 1 1 1 1 1 1...... H.. 1. 1 1 1 1 1.. 1. 1 1.... 1. SD SDH SDS Sizes 1" and 1." use URB Series (page ) 1 1... 1 1 1 1... 1 1 B. 1 1. 1. 1.... 1. 1. E......... 1.. 1 Min Max SD Min Max. 1. 1 1. 1.. 1.... 1...... 1.. 1 Min Max SDS Min Max. 1. 1 1. 1.. 1...... 1. 1. 1... 1. 1 Min Max SDH Min Max.. 1. 1. 1. 1. 1. 1. 1.... 1. 1.. 1. 1. 1. Weight 1 1, 1, 1,,,,1,, Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. Acoustical packing is suitable for F Attenuation, db Typical Attenuation Curve 1 Octave Band Center Frequency, Hz Specifications RD Group Combination Chamber- Absorptive Type Discharge Silencer The RD Series Discharge Silencer is a heavy-duty, all welded unit constructed of carbon steel sheet and plate. It provides excellent pulse control and is equipped with an acoustically treated inlet for use on critical LV applications. ulse control and noise attenuation provided by the RD Series is the ultimate and is necessary for only the most demanding installations. Sizes " and larger are equipped with flanged connections drilled to /1 lb ASI specifications. Smaller sizes are standard with male threaded pipe nipples. Units sized " and " are available in either flanged or male pipe threads. Exterior surfaces receive a shop coat of rust inhibitive primer and may be finish painted in the field if desired. The RD Series is the basic end-in, end-out configuration. A low side inlet is designated the RD Series; high side inlet, RDH Series; and low opposed connections, RDS Series. The four types are fundamentally alike and performance is identical. Mounting brackets and other options are availablesee page. L H RD Series D Drain RD Series (Low Side Inlet) RDH Series (High Side Inlet) E RDS Series (Opposed Connection) B Combination Chamber-Absorptive Type Discharge Silencers (Size) 1 1... 1 1 1 art umber --AA --AA --AA -1-AA --AA* --AA* --AA --AA -1-AA -1-AA --AA --AA --AA --AA --AA --AA --AA --AA --AA D 1 1 1 ote: Dimensions and weights are nominal and may vary slightly with production models. Request certified drawings of specific models for exact dimensions. *Specify -TT for male pipe threaded units. L 1 1...... H 1 1 1 1 1 1...... RD RDH RDS 1 1.... 1... 1 1....... 1 B 1 1. 1. 1... 1. 1... E.. 1 1. 1. 1 1. 1.. RD Min Max FIXED AT FIXED AT FIXED AT FIXED AT. 1. 1. 1. 1.. 1... 1 1 1 RDS Min Max 1 1. 1. 1. 1... 1 1 1..... 1 RDH Min Max Sizes 1" 1." use URB Series (page ) or use U Series: (Absorptive Silencers Technical Literature booklet #-1 page ). 1 1.. 1 1 1. 1 1 1 1 1.. 1. 1.. Weight 1 1, 1,,,,,,,,1 Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

Specifications SURS Group Chamber Type Multi-Use Silencer Attenuation, db Typical Attenuation Curve 1 Octave Band Center Frequency, Hz ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. SURS Series blower silencers are heavy-duty, all welded steel construction, suitable for application as either and inlet or discharge silencer on rotary positive. These units are designed for blowers running above critical transition speed, and therefore, no acoustic packing material is included in the design. Instead, these units have a specially designed, high-performance, three chamber system which incorporates a diffuser on the blower side of the silencer units. The unit will provide excellent pulse control and is designed for the most demanding applications. Sizes smaller than four inches are equipped with standard male threaded pipe nipples, while the " and larger units have flanged connections drilled to /1 lb ASI specifications. The SURS Series employs a high-heat aluminum paint system. The SURS is a basic end-in, end-out configuration. A low-side inlet model is designated as the SURS Series; the SURS is fundamentally identical to the SURS Series SURS Series (Low Side Inlet) SURS series in both dimension and attenuation performance. Both series are designed to operate at pressures to 1 psi. Mounting brackets, shell lagging and other accessories are available for both series of blower silencers. Combination Chamber Type Multi-Use Discharge Silencers SURS SURS Model art Model art SURS- SURS-. SURS- SURS-. SURS- SURS- SURS- SURS- SURS- SURS- SURS-1 SURS-1 SURS-1 SURS- -A-SS -A-SS -A-SS -A-SS -A-SS* -A-SS* -A-SS -A-SS -A-SS -A-SS -A1-SS -A1-SS -A1-SS -A-SS SURS- SURS-. SURS- SURS-. SURS- SURS- SURS- SURS- SURS- SURS- SURS-1 SURS-1 SURS-1 SURS- -B-SS -B-SS -B-SS -B-SS -B-SS* -B-SS* -B-SS -B-SS -B-SS -B-SS -B1-SS -B1-SS -B1-SS -B-SS *Specify -TT for male pipe threaded units. D L H.. 1 1 1 1 1* 1* 1 1 1 1 1 1 1 1...... 1 Min. Max Weight 1. 1. 1. 1.... 1 1 1 1 1 1 1 1 1 1 1 1, 1, 1,1,, Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

CBF/CBFI Series Compact Blower Inlet Filter-Silencer ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. Filter and silencer combined in one unit. The CBF and CBFI have the acoustic capabilities of the Universal Silencer RIS Series silencers and the filtration performance of CC series filters. Reduced cost, overall package size, weight, storage space, freight cost and damage. ¹ ₈" T pressure tap CBF Series (outdoor use) WD Removable weatherhood for filter element access ¹ ₈" T pressure tap CBFI Series (indoor use) WD Removable plate for filter element access Approximately one third the size of conventional blower silencer, with the added benefit of excellent, high-efficiency filtration. Reduced overall package noise without further acoustic treatment. VersatileSuitable for inlet applications in confined areas, outdoor or indoor, without compromising acoustic or pressure drop performance. (nom.). Element art umber aper Felt 1-1* 1-1* 1-1- 1-1- 1-1- 1-* 1-* 1-1- 1-1- 1-1- 1-1- *air of elements required (stacked). Wire 1-* 1-* 1-1- 1-1- 1-1- 1-1 L, inches of H O 1 H D F F F ressure Drop Curves 1 1.... Velocity, ft/min L H D Models, Dimensions, Weights and Elements (nom.). D 1 1 CBF/CBFI H CFM CA art.. 1 1........ 1. 1. 1. 1. 1.. 1 1,,,, --AA --AA --AA --AA --AA --AA --AA --AA --AA otes: 1. on-asme Code construction suitable for 1" Hg vacuum.. Weights are approximate and do no include the weight of the filter element. CBF WD L Weight art 1 1 1. 1. 1 1.. 1 -G-AA -G-AA -G-AA -G-AA -G-AA -G-AA -G-AA -G-AA -G-AA CBFI WD L 1 Weight.... 1 1 1 1 1 1 1... 1.... 1 Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

ressure Vessel Construction Silencers may be fabricated in accordance with Div. 1, Section VIIIASME Code for Unfired ressure Vessels. Dimensions are similar to standard models, but material types and thicknesses are selected to meet code requirements. rices are quoted on application to meet your pressure and temperature conditions. CB Series Compact Blower Silencer This extremely compact blower silencer works as either an inlet or discharge silencer on rotary positive blowers. It is about one-third the size of a standard silencer, and reduces overall package size, cost, weight and storage space. The unit s internal pack material is suitable for temperatures up to degrees. The unit is operable in conditions up to 1 psig. Flanged or threaded connections are available. Exterior surfaces receive a shop coat of rust inhibitive primer. L H D ressure Drop Curves Attenuation, db Typical Attenuation Curve 1 Octave Band Center Frequency, Hz Compact Blower Silencers, inches of H O 1 F F F 1 1.... Velocity, ft/min Model CB- CB-. CB- CB- CB- CB- CB- CB- CB- art umber (nom.) D L H Weight --AA --AA --AA --AA --AA --AA --AA --AA --AA. 1 1. 1. 1 1.. 1 1........ 1. 1. 1. 1. 1.. 1 CFM CA 1 1, 1,,, Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

UI-BASE Ultra-Wide Base lates/components Rotary ositive Blowers These wide base plate products accommodate a variety of blower package designs. The UI- BASE package and the USI-BASE base plate use the same basic base plate and discharge silencer. The UI-BASE package includes the Universal Silencer model URB high-side inlet silencer and CCF inlet air filter, while the UI- BASE base plate is only the basic plate and the URB discharge silencer. lease see page for performance and sizing information for the URB series silencers, page for information on the URB series silencers, and page in Filters and Filter-Silencers (#-1) for performance data, weights and dimensions of CCF filters. UI-BASE ackage CCF (see Filter and Filter-Silencers Technical Literature #-1 page ) URB (see page 1) URB (see page ) UI-BASE Base late Only URB (see page ) UI-BASE Base lates/components art umbers Size. UI-BASE ackage -1-1 -1-1 -1-1 Base late Only URB Only URB Only CCF Only --AB --AB --AB --AB --AB --AB --AA --AA --AA --AA --AA --AA --AA --AA --AA --AA --AA --AA -L-TT* -L-TT* -L-TT* -L-TT* -L-TT* -L-TT* *Specify at end of part number for unit with pleated paper elements, F for pleated felt or W for wire mesh. Refer to Filter and Filter-Silencers Technical Literature booklet #-1 for filter element details. Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

UI-BASE Ultra-Wide Base lates/components Rotary ositive Blowers Dimensions and Weights UI-BASE Base late (w/urb) (nom.) A B C CD D E FS.. 1. 1... 1.... 1. 1. 1. 1 1 1... 1.. 1 1. 1. 1. 1. 1. G H J L Q (Dia.) S.... 1 1 1... 1... 1.... Approx. Weight 1 otes: 1. Sizes " " URB discharge silencers are shipped standard with male pipe threaded connections. " and " URB discharge silencers are shipped standard with male pipe threaded discharge connections and plain pipe blower connections. " URB discharge silencers are shipped standard with flanged discharge connection drilled to /1 lb. ASI specifications and plain pipe blower connections.. Sizes " " URB discharge silencers have a " T relief valve coupling and plug. Sizes " " URB discharge silencers have a " T relief valve coupling and plug. URB Silencers 1/ (nom.) D1 H1 1 1 Approx. Weight. 1 1 1 otes: 1. Sizes " " URB inlet silencers are shipped with male pipe threaded inlets and plain pipe outlets. Sizes " and " URB inlet silencers are shipped standard with flanged inlet connections drilled to /1 lb ASI specifications and plain pipe outlets...... 1 1 Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

All information correct at time of printing. Universal has a policy of continuous improvement. Therefore we reserve the right to change the specifications of these silencers without notice. Weld-On Attachment Brackets All dimensions are in inches unless otherwise stated. All weights are in lbs and are approximate. Universal provides several options for attaching the silencer to a structure or floor. Vertical silencer installations have a Type B or D attachment option. Horizontal silencer installations have a Type E or Type F attachment option. lease indicate attachment option on order. The brackets and legs will be factory installed so no field welding is required. (age.) (age.) Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

All information correct at time of printing. Universal has a policy of continuous improvement. Therefore we reserve the right to change the specifications of these silencers without notice. All dimensions are in inches unless otherwise stated. All weights are in lbs and are approximate. Weld-On Attachment Brackets Type B Mounting Brackets* Body Diamter A B C D E. C.... 1.. C.... 1.. C.... 1. 1. C.... 1. 1. C..... 1. C...... C...... C...... C...... C...... C...... C...... C...... C.... *Add to the part number when ordering a silencer with Type B brackets (for example, a F would be ordered as ). Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

All information correct at time of printing. Universal has a policy of continuous improvement. Therefore we reserve the right to change the specifications of these silencers without notice. Weld-On Legs All dimensions are in inches unless otherwise stated. All weights are in lbs and are approximate. Type D Mounting Brackets* - Legs Body Diameter A Hole Diameter Foot Width Foot Gauge Leg Angles F........1.........1.........1. 1. 1.......1. 1. 1.......1. 1. 1.......1................................................ 1......... 1......... 1....... *Add E to the part number when ordering a silencer with Type D brackets (for example, a F would be ordered as E). Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

All information correct at time of printing. Universal has a policy of continuous improvement. Therefore we reserve the right to change the specifications of these silencers without notice. All dimensions are in inches unless otherwise stated. All weights are in lbs and are approximate. Weld-On Attachment Brackets Type E Mounting Brackets* Body Diamter A B C D E. C.... 1.. C.... 1.. C.... 1. 1. C.... 1. 1. C..... 1. C...... C...... C...... C...... C...... C...... C...... C...... C.... *Add C to the part number when ordering a silencer with Type E brackets (for example, a F would be ordered as C). Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

All information correct at time of printing. Universal has a policy of continuous improvement. Therefore we reserve the right to change the specifications of these silencers without notice. Weld-On Attachment Brackets All dimensions are in inches unless otherwise stated. All weights are in lbs and are approximate. Type F Mounting Brackets* Body Diamter A B C D E F G H J L.......... 1. 1......... 1. 1...... 1.. 1...1. 1...... 1...... 1...... 1.....1. 1. 1.. 1... 1.....1. 1. 1.. 1.. 1. 1. 1....1.. 1.. 1.. 1. 1. 1....1...... 1. 1. 1........... 1. 1... 1........ 1. 1... 1........ 1. 1... 1........ 1. 1... 1........ 1. 1........... 1. 1........... 1. 1...... *Add to the part number when ordering a silencer with Type F brackets (for example, a F would be ordered as ). Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

otes: Frequently the engine s flange size is larger than the required silencer s connection. Rather than use a larger silencer, it is usually more economical to use an oversize reducing flange on the silencer. Universal offers single reduction and double reduction ASI Flange. Reduction/Oversize Flange its Reduction Flange: Single ipe Size Reduction art umber A D # of Holes B C E Weight x -1.... x -1..... x -1. 1.... 1 x -1. 1. 1. 1.. 1 x -1. 1. 1. 1.. 1x -. 1. 1. 1.. 1x1-1 1.1. 1 1. 1.. 1x1-1.1. 1. 1.. x1-1.1.. 1.. x -.1.. 1.. x -.1. 1.. Reduction Flange: Double ipe Size Reduction art umber A D # of Holes B C E Weight x -..... x -. 1.... 1 x -1. 1. 1. 1.. x -. 1. 1. 1.. 1x -. 1. 1. 1.. 1x -.. 1 1. 1.. 1 1x1-1.1. 1. 1.. x1-1.1.. 1.. x1-1.1.. 1.. x -.1.. 1.. x -.1. 1. 1.. Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

Companion Flange its Field repairs, retrofits and custom projects sometimes require flanges to be installed on a bare pipe end. Universal offers weld-on flanges. Each flange kit includes two flanges, gaskets, and bolt and nut for each hole. Companion Flange ipe Size art umber A Inner Diameter D Outer Diameter # of Holes C Hole Diameter T Flange Thickness -1... -1.... -1.... 1-1. 1... 1 -. 1. 1.. -1. 1. 1.. 1-1 1.1 1. 1.. 1-1 1.1. 1 1.. 1-1 1.1. 1 1.. -1.1. 1.. -1.1. 1.. 1 Weight Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev 1

Field repairs, retrofits and custom projects sometimes require flanges to be installed on a bare pipe end. Universal offers weld-on flanges. Each flange kit includes two flanges, gaskets, and bolt and nut for each hole. Companion Flange its Dual Mounting Flanges its (Threaded) art umber A B C D E F G # of Holes Weight... 1.1..1... 1...... 1. 1.... 1. 1. 1.. A kit consists of a mounting flange, a gasket, and one capscrew and nut for each mounting hole. Available in dual or single flange kits. Listed part number for dual flange kits. lease call for single flange kits. Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev

Universal 1 Highway 1/1.O. Box Stoughton, WI USA hone () - Fax () - Universal Acoustic & Emission Technologies, Inc. All rights reserved. Toll-Free: 1--- -1 Rev