SERIES 54 Inductive Proximity Sensor

Similar documents
SERIES 54 PROXIMITY SENSORS

Technical Data. Dimensions

Solenoid coils VACF Type codes

Ex m Solenoid Operator Type 0519

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

INSTRUCTION MANUAL (ATEX / IECEx)

Sensor boxes SRBE Key features and product range overview

Operating Instructions

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Type Electronic Limit Switch

Operating Instructions

INSTRUCTION MANUAL (ATEX / IECEx)

Control and Terminal Box Type A21-**-*****

SERIES 54 PROXIMITY SENSORS

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

OPERATING INSTRUCTIONS

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

VALIADIS S.A. HELLENIC MOTORS

Linear actuators DFPI

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

Electronic Limit Switch Type

SERIES 54 PROXIMITY SENSORS

Integrated Control modules

Solenoid Valves Type 3963

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Series 3730 Electropneumatic Positioner Type

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

3/2 and 4/2 directional seat valves with solenoid actuation

Solenoid coils. Festo core product range Covers 80% of your automation tasks

Integrated Control modules

Operating Instructions

Type 3768 Inductive Limit Switch. Mounting and Operating Instructions EB 8356 EN

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Clarius EP PLUS LED FLOODLIGHT Installation Guide

Limit Switch Type 3776

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Solenoid Operator 0516 / 1216

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Pneumatic control unit for decentralized automation of ELEMENT process valves

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

EStrong-series Emergency Stop

SynergEX Panelboards for Hazardous Locations

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type Z & Ex pz purge and pressurization system

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

ILED Dorado. User Manual

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Limit switch attachments DAPZ

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Limit Switch Type 4747

Floodlight Range Installation Guide

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Emergency Luminaire with LED Series EXLUX 6409/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

YFC. Limit switch. Ex d. 24 operating head types

DIAMOND POINT VIBRATING PROBES

Compact Sheet-Steel Light Fittings Series 6114/1

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

Solenoid Valve Island Type 3965

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Linear Luminaire with LED Series EXLUX 6402/2

Terminal Boxes in Stainless Steel SLS**.T

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

PHOENIX CONTACT - 01/2008

Operating Instructions

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

ATX DPD Series Distribution Panelboards Flameproof

Leading the way in hazardous areas Features EATON

Instruction Manual. Ex-Time 40 / 50

Compact pressure switch Model PCS

Material pressure (bar) (Cv (US) kv x 1,2 Seat

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Transcription:

SENSOR FEATURES > 2-wire DC sensor with minimum off-state current > ATEX-approval for zone 2 and zone 22 > High temp, UV, salt water resistant > Rugged metal base > IP66/67/69K > High impact protection > Removable plug-in terminals > Large terminal space for easy wiring DIMENSIONS TECHNICAL DATA General specifications Switching function Output type 2 x normally open (NO) Two-wire Rated operating distance sn 2.5mm Installation Output polarity For non-flush mounting DC Assured operating distance sa 0... 2.05mm Output type Nominal ratings 2 x 2-wire Operating voltage UB 6... 30V Switching frequency f 0... 100 Hz Hysteresis H Typical 0.5 mm Reverse polarity protection Short-circuit protection Reverse polarity tolerant No Voltage drop Ud 6 V Operating current IL 4... 100mA Off-state current Ir 100... 200 µa, typical 160 µa Functional safety related parameters MTTFd 684 a Mission Time TM 20 a Diagnostic Coverage DC 0% Electrical specifications - valve circuit Voltage Current Ambient conditions 10... 32V Max. 240 ma Ambient temperature TA -40... 75 C (-40... 167 F), restriction for use in hazardous area, see instruction manual Storage temperature Mechanical specifications -40... 85 C (-40... 185 F) Connection (system side) M20 x 1.5 cable gland, ground connection + earthing screw only for wire cross-section 4mm 2, use solid wire or stranded wire + wire end ferrule Connection (valve side) Screw terminal, cable gland M20 x 1.5 Housing material Housing base Degree of protection Rugged polycarbonate (PC) + GF 10%, optimized for outdoor use Powder coated aluminum IP67; additional degree of protection IP66/IP69K with 540100-70600533 and 540100-21900533 S9-1 of 6

TECHNICAL DATA Terminal assembly Number 10 Connection type Type For connection of copper wires with 7 mm dismantle length. Tightening torque 0.5... 0.6 Nm Screw terminal block, pluggable Terminal capacity Conductor cross-section 0,25... 2,5 mm 2, flexible/rigid. For Multiple-wire connection: two wires of equal cross-section per 0.25...1 mm 2 Tightening torque, fastening screws Tightening torque, housing screws Tightening torque, earthing screw Tightening torque, cable gland Tightening torque, stopping plug General information Use in the hazardous area Category Compliance with standards & directives 2 Nm 1.5 Nm 1.5 Nm 4 Nm 2 Nm See instruction manuals 3G; 3D Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 CCC approval VDI / VDE 3845 Approval and marking not required for products rated 36 V ASSEMBLY ACTIVATOR AND MOUNTING ASSEMBLY FEATURES > High-visibility valve position display > Protection against contamination and damage > Three level adjustable > Suitable for CW or CCW operation > 30 x 80mm actuator mounting > 30 x 130mm actuator mounting TECHNICAL DATA General specifications Housing material Activator material Protective cover material Valve status indicator Indicator adjustments Activator adjustment top level Activator adjustment bottom level Activator markings Hardware Activator targets PC PA V4A/316L Red = CLOSED Green = OPEN 5 degree increments 5 degree increments 90 degree increments 5 degree increments 316 stainless steel 303 stainless steel DIMENSIONS 30 105 83 60 207 S9-2 of 6

INDUCTIVE SENSOR KIT 30 x 80mm mounting pattern, adjustable activator Description Hardware Kit Part Number Bray S92/93 Sizes 63 to 128 and Series 98 NAMUR VDI/VDE 3845 Compliant mounting metric 540102-12650536 Bray S92/93 Sizes 63 to 128 imperial 540102-12600536 Series 92/93 Actuator Series 98 Actuator Part List Qty Metric (540102-12650536) Imperial (540102-12600536) 1 Sensor 540102-71104533 Sensor 540102-71104533 1 Activator assembly Activator assembly 1 Protective cover - Zone 2/22 Protective cover - Zone 2/22 2 Socket head capscrew M5X0.8X12, Stainless Steel Socket head capscrew #10-32X1/2, Stainless Steel See Series 54 IOM for full mounting details. 30 x 80mm mounting pattern, adjustable activator Description Hardware Kit Part Number Bray S92/93 Sizes 160 to 255 NAMUR VDI/VDE 3845 Compliant mounting metric 540102-12651536 Bray S92/93 Sizes 160 to 210 imperial 540102-12601536 Series 92/93 Actuator S9-3 of 6

Part List Qty Metric (540102-12651536) Imperial (540102-12601536) 1 Sensor 540102-71104533 Sensor 540102-71104533 1 Activator assembly Activator assembly 1 Protective cover - Zone 2/22 Protective cover - Zone 2/22 1 Mounting plate assembly Mounting plate assembly 2 Socket head capscrew M5X0.8X10, Stainless Steel Socket head capscrew #10-32X3/8, Stainless Steel See Series 54 IOM for full mounting details. WIRING DIAGRAM APPLICATION Note: The connections to this sensor are sealed with stopping plugs to protect against dirt and moisture. If not all of the connections are used in your application, then seal the remaining stopping plugs on the sensor permanently or check during initial installation and when performing regular maintenance work that the stopping plugs are secure and impermeable. If necessary, tighten the stopping plugs to a torque of 2 Nm. Shield INSTRUCTION MANUAL - GC (NA) Equipment protection level Dc (tc) Manual electrical apparatus for hazardous areas - Gas Group IIIC Device category 3G (na) For use in hazardous areas with gas, vapor and mist Certificate BR 17 CERT 1705 X CE marking ATEX marking Standards General Installation, commissioning Maintenance Special conditions Maximum operating current [IL] Maximum operating voltage [U B max] Maximum permissible ambient temperature [TUmax] at UBmax=30 V, IL =100 ma, T6 at UBmax=30V, IL=100 ma, T1... T5 at UBmax=30 V, IL =50 ma, T6 II 3G Ex na IIC T6... T1 Gc The Ex-related marking can also be printed on the enclosed label. EN 60079-0:2012+A11:2013, EN 60079-15:2010 - Protection by increased safety na. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indel ible, including in the event of possible chemical corrosion. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. Seal any openings on the housing not in use, using the stain less steel stopping plugs supplied. No other devices should be used to seal the open ings. The stopping plugs made of plastic must no longer be used. No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. The maximum permissible load current must be restricted to the values given in the fol lowing list. High load currents and load short circuits are not permitted. The maximum permissible operating voltage UBmax is restricted to the values in the following list. Tolerances are not permitted. Depending on the load current IL, the maximum operating voltage UBmax, and the tem perature class. Details can be found in the following list. 35 C (95 F) 57 C (134.6 F) 35 C (95 F) S9-4 of 6

INSTRUCTION MANUAL - GC (NA) at UBmax=30 V, IL =50 ma, T1... T5 Maximum values of the valve circuit Protection from mechanical danger Protection from UV light Electrostatic charge Lead insertion Material selection accessories Plug connector 60 C (140 F) Uv = 32 V; Iv = 240 ma The sensor must not be exposed to any form of mechanical danger. If you use the protective cover 540100-70600533 and the actuator with protective cover 540100-21900533, it is ensured that the device is sufficiently protected in accordance with IEC/EN 60079-0. If protective cover becomes damaged, replace the protective cover. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. If you use the protective cover 540100-70600533 and the actuator with protective cover 540100-21900533, it is ensured that the device is sufficiently protected in accordance with IEC/EN 60079-0. If the protective cover becomes damaged, replace the protective cover. Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. If cable glands are required for the installation, then the following points must be observed. The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the applica tion. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application. When selecting accessories, ensure that the material allows the temperature of the enclosure to rise to up to 70 C. The plug connector must not be withdrawn under voltage. The proximity switch is identi fied as follows: "WARNING DO NOT SEPARATE WHEN ENERGIZED. With the plug connector disconnected, soiling of the internal area must be prevented. (i.e. the area that is inaccessible when the connector is inserted). INSTRUCTION MANUAL - Dc (tc) Equipment protection level Dc (tc) Manual electrical apparatus for hazardous areas - Dust Group IIIC Device category 3D (tc) For use in hazardous areas with combustible dust Certificate BR 17 CERT 1705 X CE marking ATEX marking Standards General Installation, commissioning Maintenance Special conditions Maximum operating current [IL] Maximum operating voltage [UBmax] II 3D Ex tc IIIC T80 C Dc The Ex-related marking can also be printed on the enclosed label. EN 60079-0:2012+A11:2013, EN 60079-31:2014 - Protection by enclosure "tc" The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.bray.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. Seal any openings on the housing not in use, using the stainless steel stopping plugs supplied. No other devices should be used to seal the openings. The stopping plugs made of plastic must no longer be used. No changes can be made to apparatus, which are operated in hazardous areas. Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. The maximum permissible load current must be restricted to the values given in the fol lowing list. High load currents and load short-circuits are not permitted. The maximum permissible operating voltage UBmax is restricted to the values in the following list. Tolerances are not permitted. S9-5 of 6

INSTRUCTION MANUAL - Dc (tc) Maximum permissible ambient temperature [TUmax] at UBmax=30 V, IL=100 ma, T80 C at UBmax=30 V, IL=50 ma, T80 C Maximum values of the valve circuit Protection from mechanical danger Protection from UV light Electrostatic charge Lead insertion Plug connector Dependant of the load current IL and the maximum operating voltage UBmax. Details can be found in the following list. 57 C (134.6 F) 60 C (140 F) U V = 32 V; I V = 240 ma The sensor must not be exposed to ANY FORM of mechanical danger. If you use the protective cover 540100-70600533 and the actuator with protective cover 540100-21900533, it is ensured that the device is sufficiently protected in accordance with IEC/ EN 60079-0. If the protective cover becomes damaged, replace the protective cover. The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. If you use the protective cover 540100-70600533 and the actuator with protective cover 540100-21900533 it is ensured that the device is sufficiently protected in accordance with IEC/EN 60079-0. If the protective cover becomes damaged, replace the protective cover. Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. If cable glands are required for the installation, then the following points must be observed. The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the application. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application. The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented. (i.e. the area that is inaccessible when the connector is inserted). All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of Bray International, Inc. The technical data herein is for general information only. Product suitability should be based solely upon customer s detailed knowledge and experience with their application. Bray is a registered trademark of Bray International, Inc. 2017 Bray International. All rights reserved. TM-BC-1060_S54_0102_EU-EN_2017-12-06 S9-6 of 6