ICETRON ECOLOGIC Inductively Coupled Fluorescent System

Similar documents
QUICKTRONIC ICE Universal Voltage Systems

State of New Jersey BOARD OF PUBLIC UTILITIES 44 SO. CLINTON STREET 7 TH FLOOR P.O. BOX 350 TRENTON, NEW JERSEY

JOB NAME MODEL NO. LAMP OUTPUT VOLTAGE

The new standards affecting the lighting industry. Educating you now and into the future.

Ballast Technology & Specification Guide SYLVANIA QUICKTRONIC Electronic Ballasts

UID ULTRA INDUCTION SERIES ULTRA INDUCTION DOME. APPLICATIONS High and low bay applications, gymnasiums, etc. FEATURES

SubstiTUBE IPS LED T8

SALE on HID Bulbs at take additional 5% Off with coupon code 5PDF. SYLVANIA LUMALUX High Pressure Sodium Lamps

Product Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g

Appendix A Preliminary Floor System Layouts and Estimates

CORE AND COIL, DRY CAPACITOR, BRACKET, IGNITOR, MOUNTING HARDWARE 3-15/16 INCH L X 2.13 INCH W X 2-3/16 INCH H

PrevaLED Line High Flux

2011 DOE Fluorescent Ballast Rulemaking. Susan Isenhour Anderson Manager of Energy Relations OSRAM SYLVANIA July 2012

20W LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - Class 1 Division 2

SYLVANIA ICETRON INDUCTIVELY COUPLED ELECTRODLESS LIGHTING SYSTEM DESIGN GUIDE

LEDlescent TM T8 Ballast-Free Lamps

200W High Bay LED Fixture V AC 50/60 Hz - Aluminum - Cold Forged Housing - IP65

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp

20W LED Strip Light for Hazardous Location - 24" Surface Mount Bar - Motion, Day/Night Sensor - C1D2

TCPHB4UNI1250K10 4' 12, 000 Lumen Unv Volt Led High Bay 5000K

CRI INDUCTION LUMEN MAINTENANCE LONG-LASTING BENEFITS THE EVOLUTION OF LIGHTING

16 Watt White LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - C1D2

Steve Sindoni Commercial Engineer OSRAM Sylvania

Luminaires - LED High Bay

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

ECO EXT (DIMMABLE)

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications

2001 TMT Associates 1

Emerging Lighting Technologies IEEE - March 21, 2001

Solid State T8 tube is the smart alternative to a

OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

100ft Temporary Construction String Light - Ten LED Work Lamps Watt LED Stringer - 12/3 SJTW

KLED18STD. Product Overview. 18w LED DD Standard, 30000hrs

HOW IS LIGHT PRODUCED

50ft Temporary Construction String Light - 5 LED Work Lamps - 50 Watt LED Stringer - 12/3 STJW

1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket

PRODUCT SPECIFICATIONS

ICN2S40N35I Ele Ballast (2) F40T V

15W (+/- 1W) 5.08" diameter x 0.75 H. Energy Star Luminaire CSD

LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

Reduce Maintenance Costs *

Spiral T2 10,000 & 8,000 hours

34W (+/- 1W) 9.55" diameter x 0.81 H. 2.5kV Common and Differential mode (Per ES Ring Wave Test) Sound Rating / Noise

LED Strip Light - LED Rail Light Inch LED - 4 Watts Lumen V DC

23W (+/- 1W) Leading Edge (TRIAC) or Trailing Edge (ELV) /100% ~ 10% Beam Angle CRI Operating Temperature Range (Ta) Maximum Engine Case Temperature

RELB2S40N35I (2)F40T12 120V Ele BLST

Evolve LED Roadway Lighting

Cynergy Series Retrofit Kit

TRUET5 EXT (DIMMABLE)

HIGH INTENSITY DISCHARGE BALLASTS

FLUORESCENT LAMPS FEATURES & BENEFITS ULTRA 8 LINEAR AND U-BEND LAMPS FOR GENERAL LIGHTING

23W Dimmable LED Bulb - 4' T8 Lamp Lumens - Double Ended- Replacement/Upgrade for Fluorescent

Encounter Metric Recessed LED Luminaire

TUNABLE SPECTRUM/TUNABLE WHITE

GE Evolve LED Post Top Contemporary Twin Support Post Top (EPTC)

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

TUNABLE SPECTRUM/TUNABLE WHITE

EcoSystemR Multiple Control Input Ballasts

Lumination LED Luminaires

GE Lighting. Heavy Industrial High Bay & Low Bay Lighting. (ABR1 - Series) imagination at work


136W Wash Down LED Light - 120/277V AC - Food Safe - IP66 Rated - Trunnion Mount

120VAC / Universal Input Rectangular LED DC Engines and LED DC Engine Retrofit Kits

LUMILUX T5 HO CONSTANT

2 LED downlight. Discreet styling, bold performance. RABWEB.COM

DESCRIPTION & APPLICATION

LSLHFL. Litespeed LHF LED Recessed Troffer. Ordering Guide. Key Features LITESPEED. Fixture Type: Project Name: Quick Find litecontrol.

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

Photo Z.Jedrus. High performance, energy-efficient linear fluorescent lamps. Philips T8 Collection

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS

INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in

Compact SE Overview. High-Performance Dimming. Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast

OUTDOOR TRACK. LABELS Assembled in America

HO CONSTANT 39 W/840. Product datasheet. LUMILUX T5 HO CONSTANT Tubular fluorescent lamps 16 mm, high output, Constant

2 LED Designer Series

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES

EcoSystem Multiple Control Input Ballasts

Lighting Tables for Existing/Base Equipment 4/15/2011

Efficacy (LM/W)* Rated Initial Lumens (LM)

LEN Series 2x2 / 2x4 LED

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control

Lighting Tables for New Equipment 2/24/2015

Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:

G4 LED HID Retrofit. Standards Manual

TRMUNV065EC8XXA TRAUNV065EC8XXA Universal Voltage LED Canopy Retrofit Kit

LED Flat Panel Luminaires

DATA SHEET: LED PANEL

Remodeler. Complete product = Frame-in kit + Light engine + Trim Order each separately. E ELV dimming 1 120V VA Version A 2 Z V

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

Highbay Fluorescent - Six Lamp Low Profile Design

Understanding Electronic UltraMax HID Ballasts

BLACK BODY DIMMING 800/1300/1500 LUMEN 6 LED NEW CONSTRUCTION/REMODEL

Lighting Tables for New Equipment 3/9/2016

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

Transcription:

www.sylvania.com ICETRON ECOLOGIC Inductively Coupled Fluorescent System Key Features & Benefits Unparalleled lamp life 100,000 hour life 10 years of continuous operation White light 3500K, 4100K, 5000K Consistent color over long lamp life Instant on/restrike Low temperature starting: -25 C with ICE40 and ICE70-40 C with ICE100, ICE150 and ICE200 Broad operating temperature range Simple connector assembly Small profile 2-prong connector with 18 to 24" leads Fits through 1/2 inch conduit Ballast remote mounting possible up to 66 feet Universal voltage ballast (120-277V) ICETRON ECOLOGIC lamp and QUICKTRONIC ballast system offers a high quality white light lamp with color consistency throughout the unparalleled long life. With a lamp life of 100,000 hours, which is equal to 10 years of continuous life, you will reduce maintenance cost without giving up light or color. This is five to ten times the typical service life of conventional fluorescent and metal halide lamps. ICETRON lamps are available in 3500K, 4100K and 5000K color temperatures with a premium phosphor blend that assures color consistency throughout the life of the lamp. 2200K in 150W available made to order. The inductively coupled electrodeless lamp uses magnetic-induction technology instead of an electrode at each end of the fluorescent tube to generate light. The absence of electrodes allows much longer lamp life. ICETRON lamps pass the Federal TCLP test, classifying them as non-hazardous waste in most states. SYLVANIA ICETRON ECOLOGIC fluorescent lamps pass the Federal Toxicity Characteristic Leaching Procedure (TCLP) 1 criteria for classification as non-hazardous waste in most states. 2 Product Offering Lamp Watts CCT ICETRON 40/2P/ECO 40 3500K, 4100K, 5000K ICETRON 70/2P/ECO 70 3500K, 4100K, 5000K ICETRON 100/2P/ECO 100 3500K, 4100K, 5000K ICETRON 150/2P/ECO 150 2200K, 3500K, 4100K, 5000K ICETRON 200/2P/ECO 200 3500K, 4100K, 5000K I E S 1. TCLP test results are based on NEMA LL Series standards and are available on request. 2. Lamp disposal regulations may vary; check your local & state regulations. 2008 PROGRESS R e p o r t SELECTION Application Information Applications Bridge/tunnel Escalators Freezers/cold storage High/low bay Indirect Indoor & outdoor Signage Street and area lighting Application Notes 1. Universal operating position For non-horizontal lamp operation, the amalgam tip should be pointed down. 2. Universal input voltage: 120-277 volts, 50/60 Hz. 3. Low EMI complies with FCC Part 18 Non-Consumer limits. Thermal Characteristics 1. Fixture must act as heat sink for lamp induction cores and ballast good thermal coupling required. 2. Maximum bulb wall temperature of 302 F (150 C). 3. Maximum magnetic ferrite core temperature is 302 F (150 C). 4. Amalgam tip temperature for 90% light output for 70W, 150W, 200W types is 130-260 F (55-125 C), 104-199 F (40-93 C) for the 40W types and 122-260 F (50-125 C) for the 100W types. 5. Tc Max (maximum allowable ballast case temp.) is: 149 F (65 C) for QT1x40 UNV-T & QT1x100 UNV-T, 158 F (70 C) for QT1x150 UNV-T, 167 F (75 C) for QT1x200 UNV-T, 160 F (71 C) for QT1x100 UNV-W & QT1x150 UNV-W. 6. Ballast may be mounted up to 66 feet from lamp. Please request remote mounting instructions. 7. For cold temperature application, use suitably enclosed fixture to maximize lumen output. 8. Amalgam tip covers (NAED 22093 or 22354 - Bulk Pack) available for faster warm-up under very cold operating conditions. 9. ICETRON TYPE-1 outdoor ballast must be within overall electrical enclosure and fully protected from any exposure to moisture. 10. 24" wiring extension/harness available (NAED 49755). Can only use one per lamp. Do not daisy chain. FL061R18 3-14

Specification Data Fixture Description: Project/Job: SYLVANIA lamp: SYLVANIA ballast: Notes: Type Ordering Information SYSTEMS Lamp Ballast Lamp System Wattage Ballast System Mean Rated Initial LPW Description Description Wattage 120/277V Factor Lumens 1 Lumens 1,2 Life 120/277V ICE40/RCT/2P/ECO QT 1X40ICE/UNV-T 40 48/47 1.00 3000 1970 100,000 63/64 ICE40/CIR/2P/ECO QT 1X40ICE/UNV-T 40 48/47 1.00 3000 1970 100,000 63/64 ICE70/2P/ECO QT 1X100ICE/UNV-T 70 79/77 1.05 6815 5645 100,000 86/89 ICE100/2P/ECO QT 1X100ICE/UNV-T 100 106/103 1.00 8600 7125 100,000 81/84 ICE100/2P/ECO QT 1X150ICE/UNV-T 100 154/149 1.38 11,900 9860 100,000 77/80 ICE150/2P/ECO QT 1X150ICE/UNV-T 150 161/156 1.00 13,000 10,775 100,000 81/83 ICE200/RCT/2P/ECO QT 1X200ICE/UNV-T 200 220/214 1.00 16,400 11,485 100,000 75/77 ICE200/CIR/2P/ECO QT 1X200ICE/UNV-T 200 220/214 1.00 16,400 11,485 100,000 75/77 LAMPS Item Ordering Initial Mean Number Description Lamp Lumens Lamp Lumens 2 Color Temp 3 CRI 3 26310 ICE40/835/RCT/2P/ECO 3000 1970 3500K 80 26312 ICE40/841/RCT/2P/ECO 3000 1970 4100K 80 26314 ICE40/850/RCT/2P/ECO 2925 1925 5000K 80 26311 ICE40/835/CIR/2P/ECO 3000 1970 3500K 80 26313 ICE40/841/CIR/2P/ECO 3000 1970 4100K 80 26315 ICE40/850/CIR/2P/ECO 2925 1925 5000K 80 26087 ICE70/835/2P/ECO 6815 5645 3500K 80 26088 ICE70/841/2P/ECO 6815 5645 4100K 80 26089 1 ICE70/850/2P/ECO 6655 5515 5000K 80 26102 ICE100/835/2P/ECO 8600 7125 3500K 80 26103 ICE100/841/2P/ECO 8600 7125 4100K 80 26105 1 ICE100/850/2P/ECO 8300 6880 5000K 80 26152 ICE150/835/2P/ECO 13,000 10,775 3500K 80 26153 ICE150/841/2P/ECO 13,000 10,775 4100K 80 26155 1 ICE150/850/2P/ECO 12,700 10,525 5000K 80 26892 4 ICE150/822/2P/ECO 12,100 10,030 2200K 80 26893 ICE200/835/RCT/2P/ECO 16,400 12,190 3500K 80 26895 ICE200/841/RCT/2P/ECO 16,400 12,190 4100K 80 26897 ICE200/850/RCT/2P/ECO 15,800 11,740 5000K 80 26894 ICE200/835/CIR/2P/ECO 16,400 12,190 3500K 80 26896 ICE200/841/CIR/2P/ECO 16,400 12,190 4100K 80 26898 ICE200/850/CIR/2P/ECO 15,800 11,740 5000K 80 1. Lumen data for 3500K and 4100K; lumens for 5000K will be slightly lower. 2. Mean Lumens at 40,000 hours. 3. Lumens, wattage, color and CRI measured @ an amalgam tip temperature of 149 F (65 C) for ICETRON 100, 158 F (70 C) amalgam tip temperature for ICETRON 70, ICETRON 150 & ICETRON 200 and 138 F (59 C) for ICETRON 40. 4. Made to order only. Contact your SYLVANIA representative for quantities and lead times. BALLASTS Item Number Ordering Description Voltage Range Compatible Lamps 49758 QT1X40ICE/UNV-T 120-277 ICE40/RCT/2P, ICE40/CIR/2P 49753 QT1X100ICE/UNV-T 120-277 ICE70/2P, ICE100/2P 49772 QT1X150ICE/UNV-T 120-277 ICE100/2P, ICE150/2P 49756 QT1X100ICE/UNV-W 120-277 ICE70/2P, ICE100/2P 49759 QT1X100ICE/UNV/DIM 120-277 ICE100/2P 49773 QT1X150ICE/UNV-W 120-277 ICE100/2P, ICE150/2P 49789 QT1X200ICE/UNV-T 120-277 ICE200/RCT/2P, ICE200/CIR/2P Note: Models rated UL Type 1 ("T" suffix) are designed for general lighting applications. Models rated UL Type 2 ("W" suffix) provide protection from water intrusion and are suitable for damp or wet locations.

Ordering Guide ICE100/835/2P/ECO ICE 100 / 8 35 / RCT / 2P / ECO ICETRON Lamp Wattage 8 = 80 CRI 22 = CCT 2200K Bulb Type 2 Prong ECOLOGIC Inductively Coupled 40W, 70W, 100W, 35 = CCT 3500K RCT=Rectangular Connector TCLP Electrodeless 150W, 200W 41 = CCT 4100K CIR=Circular Compliant 50 = CCT 5000K QT1X100ICE/UNV-T QT 1X 100 ICE / UNV -T QUICKTRONIC # Lamps Primary ICETRON Inductively Line Voltage Top Mount Lamp Wattage Coupled Electrodeless 120 to 277V Technical Information Dimensions ICE40/CIR ICE40/RCT ICE70 Dims. in. mm in. mm in. mm Height of glass H1 1.65 ± 0.04 42 ± 1 1.65 ± 0.04 42 ± 1 2.13 ± 0.04 54 ± 1 Overall height H2 2.44 ± 0.078 62 ± 2 2.44 ± 0.078 62 ± 2 2.87 ± 0.08 73 ± 2 Tube to mount height H3 0.314 min 8 min 0.314 min 8 min 0.39 min 10 min Length of main body L1 5.45 ± 0.047 138.5 ± 1.2 5.89 ± 0.047 149.5 ± 1.2 9.84 ± 0.05 250 ± 1.2 Overall Length L2 6.96 max 177 max 7.54 ± 0.08 191.5 ± 0.08 12.4 max 315 max Mount hole spacing L3 2.58 ± 0.08 65.5 ± 2 3.31 ± 0.08 84 ± 2 5.10 ± 0.15 129.5 ± 3.7 (between cores) Mount hole spacing 1.57 ± 0.04 40 ± 1 1.57 ± 0.04 40 ± 1 3.23 ± 0.11 82.0 ± 2.7 (each core) Bracket spacing L5 1.02 max 26 max 1.69 max 43 max 4.13 min 105 min Amalgam tip length L6 0.59 max 15 max 0.59 max 15 max 0.59 max 15 max Lead wire length L7 18.11 min 460 min 18.11 min 460 min 24.00 min 609.6 min Slot width S 0.20 ± 0.01 5.1 ± 0.2 Tip to centerline T 0.98 ± 0.08 25 ± 2 Width W 5.83 ± 0.12 148 ± 3 4.33 ± 0.12 110 ± 3 5.41 ± 0.06 137.5 ± 1.5 Lamp weight lb (kg) 1.04 lb 0.47 kg 1.05 lb 0.475 kg 1.8 lbs 0.84 kg Mounting Screw (Included) M4* 0.7 M4* 0.7

Technical Information ICE100 ICE150, ICE200/RCT ICE200/CIR Dims. in. mm in. mm in. mm Height of glass H1 2.13 ± 0.04 54 ± 1 2.13 ± 0.04 54 ± 1 2.28 ± 0.04 58 ± 1 Overall height H2 2.87 ± 0.08 73 ± 2 2.87 ± 0.08 73 ± 2 2.83 ± 0.08 72 ± 2 Tube to mount height H3 0.39 min 10 min 0.39 min 10 min 0.31 min 8 min Length of main body L1 9.84 ± 0.05 250 ± 1.2 13.78 ± 0.05 350 ± 1.2 11.93 ± 0.08 303 ± 2 Overall Length L2 12.4 max 315 max 16.34 max 415 max 14.17 max 360 max Mount hole spacing L3 5.10 ± 0.15 129.5 ± 3.7 9.04 ± 0.15 229.5 ± 3.7 6.46 ± 0.16 164 ± 4 (between cores) Mount hole spacing 3.23 ± 0.11 82.0 ± 2.7 3.23 ± 0.11 82.0 ± 2.7 3.27 ± 0.12 83.0 ± 3 (each core) Bracket spacing L5 4.13 min 105 min 8.07 min 205 min 5.79 min 147 min Amalgam tip length L6 0.59 max 15 max 0.59 max 15 max 0.59 max 15 max Lead wire length L7 24.00 min 609.6 min 24.00 min 609.6 min 24.00 min 610 min Slot width S 0.20 ± 0.01 5.1 ± 0.2 0.20 ± 0.01 5.1 ± 0.2 0.20 ± 0.01 5.1 ± 0.2 Tip to centerline T 0.98 ± 0.08 25 ± 2 0.98 ± 0.08 25 ± 2 1.38 35 Width W 5.41 ± 0.06 137.5 ± 1.5 5.41 ± 0.06 137.5 ± 1.5 12.20 ± 0.28 310 ± 7 Lamp weight lb (kg) 1.8 lbs 0.84 kg 2.1 lbs 0.96 kg 1.9 lbs 0.87 kg H1 H2 H1 H2 H3 L9 H3 L3 L7 L3 connection side L8 L5 L5 W W2 W1 amalgam tube L6 L7 T 11.50.457 L1 L2 ICE70, 100, 150, 200/RCT 18.60.772 L6 L1 L2 ICE40/RCT H1 H2 H3 L7 L3 W2 W1 T L6 L5 L1 L2 ICE40 CIR ICE200/CIR Type 1 Ballast Dimensions Overall: 7.15" L x 3.96" W x 1.70" H Mounting: 6.70" L x 1.90" W Packaging Quantity: 5 Weight: 1.9 lbs ea. (approx.) Type 2 Ballast Dimensions Overall: 7.10" L x 4.30" W x 1.70" H Mounting: 6.70" L x 1.90" W Packaging Quantity: 5 Weight: 2.5 lbs ea. (approx.) Input Harness 24 (609mm)

Ballast Specification Sample Specification Lamp Frequency: 190-300 KHz Input Frequency: 50/60Hz Voltage Range: 120 to 277 ± 10% UL Listed Class P, Type 1 & 2 Outdoor CSA Certification Lamp CCF: Less than 1.7 Low THD: Less than 15% 158 F (70C) Maximum Temperature for QT1X150ICE/ UNV-T at test point Tc on ballast label167f (75C) Maximum Temperature for QT1X200ICE/UNV-T at test point Tc on ballast label 149 F (65 C) Maximum Temperature for QT1X40ICE/UNV-T or QT1X100ICE/UNV-T at test point Tc on ballast label 159.8 F (71 C) Maximum Temperature for QT1X150ICE/UNV-W or QT1X100ICE/UNV-W at test point Tc on ballast label Class A Sound Rating Minimum Starting Temperature -40 F (-40 C) for ICE100, ICE150, and ICE200 systems. Minimum Starting Temperature -13 F (-25 C) for ICE40 and ICE70 lamps on QT1X40ICE/UNV-T or QT1X100 ICE/UNV-T Power Factor: Greater than 95% FCC 47CFR Part 18 Non-Consumer ANSI 62.41 Cat. A Transient Protection System shall be (40W, 70W, 100W, 150W or 200W) ICETRON ECO inductively coupled electrodeless lamp and ballast system having (3000, 6815, 8600, 11,900, 13,000 or 16,400) system lumens. System shall have an average rated life of 100,000 hours. Warranty QUICK 60+ OSRAM SYLVANIA lamp and ballast combination - Limited 5 year lamp and ballast warranty is possible if both lamps and ballasts are provided by OSRAM SYLVANIA. See the QUICK 60+ warranty for details and restrictions. Technical Information % Rated Lumens 100 95 90 85 80 75 70 65 60 55 50 Lumen Maintenance for 70, 100 and 150W ICETRON* 0 20,000 40,000 60,000 80,000 100,000 Burning Hours *Contact OSRAM SYLVANIA for 40 & 200W Lumen Maintenance Data United States OSRAM SYLVANIA 100 Endicott Street Danvers, MA 01923 1-800-LIGHTBULB Trade Phone: 800-255-5042 Fax: 800-255-5043 National Accounts Phone: 800-562-4671 Fax: 800-562-4674 OEM/Special Markets Phone: 800-762-7191 Fax: 800-762-7192 Retail Phone: 800-842-7010 Fax: 800-842-7011 SYLVANIA Lighting Services Phone: 800-323-0572 Fax: 800-537-0784 Display/Optic Phone: 888-677-2627 Fax: 855-543-1043 180 Luminous Intensity Distribution 150 210 120 cd/1000 lm 240 Related Literature 90 270 0 Degrees 45 Degrees 90 Degrees SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc. ICETRON, ECO, ECOLOGIC and QUICK 60+ are registered trademarks of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH. Specifications subject to change without notice. 60 10 30 50 70 90 110 QUICKTRONIC ICE ballast (Literature Code: ECS451) QUICKTRONIC ICE DIM ballast (Literature Code: ECS454) QUICK 60+ System Warranty (Literature Code: ECS140) 300 30 330 1300 90 o o 45 0 o 45 o If the lamp is operated in the vertical or an angled position, the lamp should be mounted with the amalgam tip in the downward position. /sylvania /sylvania Canada OSRAM SYLVANIA LTD. 2001 Drew Road Mississauga, ON L5S 1S4 1-800-LIGHTBULB Trade Phone: 800-263-2852 Fax: 800-667-6772 OEM/Special Markets/Display/Optic Phone: 800-265-2852 Fax: 800-667-6772 Retail Phone: 800-720-2852 Fax: 800-667-6772 SYLVANIA Lighting Services Phone: 800-663-4268 Fax: 866-239-1278 Mexico OSRAM MEXICO Tultitlan/Edo de Mexico Phone: 011-52-55-58-99-18-50 ENCELIUM Products United States Phone: 201-508-1570 Fax: 201-508-1589 Canada Phone: 905-731-7678 Fax: 905-731-1401 www.sylvania.com 2014 OSRAM SYLVANIA 3-14 Photography