Controlled Power HSN High Speed DC Circuit Breakers

Similar documents
Power Break II Switchboard

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

PIX-H Metal-clad switchgear up to 17.5kV

Critical Power Switchboards. Selection and Application Guide

Switchgear. Low Voltage

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

17.1. Low Voltage Switchgear. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Publication No.: PSG

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

University of Houston Master Construction Specifications Insert Project Name

Low Voltage Switchgear

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Magnum IEC Low Voltage Air Circuit Breakers

DPX Magnetic only

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Vacuum Circuit Breaker Type VAD-3

Contents. Page INTRODUCTION Power/Vac GUIDE FORM SPECIFICATION thru

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

33KV INDOOR SWITCHGEAR

BILL OF MATERIAL 2 C EA SP CURRENT TRANSDUCER BI-DIRECTIONAL, MV INPUT, MA OUTPUT, 125VDC POWER SUPPLY SMC

TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Medium Voltage Metal-Enclosed Switches

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

DMX 3 -I 2500 switch disconnectors

ABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Underground Distribution Switchgear

Individual breakers in separate enclosures can be applied in low voltage distribution systems through 600 volts Ac, 50/60 Hertz.

Power/Vac Vacuum Replacement Breakers for GE Magne-Blast Type AM & AMH Breakers

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Cutler-Hammer May 2001

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Installation, Operation, and Maintenance Manual Retain for Future Use. EntelliGuard G Circuit Breaker

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

cor Long Run Experience

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

RPS Plus switchgear. Introduction & overview September 2013

MESG 12 / 17.5 / 24 / 36 KV

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Medium Voltage Metal-Enclosed Switches

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION

Metal Clad VCBs ~ Mk1

A. Submit manufacturer's literature and technical data before starting work.

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

RAPIER DSB Disconnectors

AIR INsULATeD switchgear >> PIX. up to 24 kv. Air-insulated switchgear with vacuum circuit-breaker. system configuration.

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Switchboard MaxSB. Low Voltage Products and Systems. Power. Distribution Systems

Medium Voltage. ANSI C37.20 and NEMA SG-5

Low Voltage Power Circuit Breaker

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Medium voltage vacuum circuit breaker. E-VAC series

MaxSG Low Voltage Switchgear

Masterpact NW DC Circuit Breakers

Service Entrance Methods

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

K-Line Plus Type KP-8 thru KP-20

Masterpact NW DC Circuit Breakers

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

Air Circuit Breakers

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

MV12 SINGLE BUSBAR VACUUM SWITCHGEAR 12KV, 800/1250/2000/2500A, 25/31.5kA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTION MANUAL

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Transcription:

Controlled Power HSN High Speed DC Circuit Breakers Each CP Type HSN circuit breaker unit can consist of either a wheeled truck and housing or be panel mounted. The circuit breaker can be mounted on the truck together with its mechanism, controls, closing, and tripping devices. The housing contains bus bars, cable connections, isolating contacts together with control relays and metering equipment. It is normal for a number of circuit breaker units to be side-by-side to form a switchboard. Housings which make up a switchboard are bolted together, while trucks remain independent, and can be readily inserted or withdrawn without disrupting the others. All trucks of a similar current rating are fully interchangeable. Control switches and indicator lamps for each circuit breaker are mounted on the front panel of the truck. The control selector switch selects either local or remote control. The trip and close switch trips the breaker direct and either closes the breaker direct or initiates the load measuring auto-reclose sequence. The closing operation is powered by the closing solenoid which also charges the opening springs. The breaker can be closed by hand using the manual closing handle provided when UV is not supplied, but this is intended for emergency and maintenance operations only. Step-down type housing designs are typically used in applications where the front panel must contain all metering and applicable instrumentation, or where minimal housing depth is important (such as inside traction power substations). Electric Close/Trip Local/Remote Selector Close/Open Indicator Counter Manual Trip Button Manual Closing Racking Typical HSN Breaker Elements HSN High Speed Circuit Breaker.

HSN Circuit Breaker Ratings and Performance: The HSN Type circuit breakers manufactured by CP have been tested in both open and closed type housings and free standing, in accordance with ANSI, BS and IEC specifications: ANSI C37-14:1979 BS 4752:1977 IEC 157:1976 ANSI C37-16:1980 BS 5227:1975 IEC 298:1981 ANSI C37-17:1972 ANSI C37-20:1974 Short Circuit Rating and Performance to BS/IEC Requirements: 800V - 120kA sustained with 0.015 second time constant 1600V - 60kA sustained with 0.015 second time constant Short Circuit Rating and Performance to ANSI Requirements. HSN switchgear is designed to meet the full requirements of ANSI specifications C37-16:1980 and C37-14:1979. Figure 1 below illustrates these requirements at 800 volts and also the compliance of the HSN switchgear which exceeds the requirements of all known applications. Typical ANSI C37-16 test A results are shown in Figure 2. Figure 1 Figure 2 Curve 1 = Requirements to table 11 Curve 2 = Requirements to table 11A Curve 3 = HSN type tests Type Tests carried out at 1600 volts exceeds the requirements of ANSI C37-16:1980 table 11A. As applications having longer time constants develop, proving tests are being performed using the special equipment necessary. Figure 3 - Performance Ratings Table based on 800/1600 Volt

Maximum Safety: Interlocks - In order to protect both equipment and operator from the dangers of operational error, as defined in ANSI Standards, each unit and breaker is provided with a system of mechanical interlocks which prevents: 1) The circuit breaker from being moved from connected, test or disconnected positions unless the main contacts are open and prevented from closing. 2) The breaker being closed unless it is in connected, test or disconnected positions, or when fully withdrawn. 3) The breaker causing damage to shutters (a stop restricts the travel of the truck within it s unit). An optional interlock is also available to prevent a breaker of incorrect rating or function being engaged in a unit. Padlocking points can also be provided to prevent unauthorized operation.

Typical HSN Circuit Diagram: HSN Circuit Breaker Dimensions: Dimensions shown in Inches Note: 4000A & 6000A breakers can be furnished for use in 24" wide cells.

HSN High Speed Stationary Mounted Circuit Breaker: HSN High Speed Circuit Breaker Options: Stationary Mounted or Drawout Kirk Key Interlock Provision 125 VDC, 120 VAC Control Voltage lnstantaneous Under Voltage Device Hinged Arc Chute (Stationary Only) High Speed Impulse Trip HSN Circuit Breaker Net Weights (LBS): Series Trip Indication Local Control Switch Double Shunt Trip Coils Remote/Local Selector Circuit Breaker Rating Stationary Mounted Breaker Draw-out Breaker 4000 496 840 6000 520 864 8000 556 1010 10000 588 1040 12000 620 1075 Controlled Power HSN Retrofitting Controlled Power can retrofit your existing Bertram Thomas and GEC breakers with our HSN Breaker and extend the life of your equipment. We can convert from blow-out coil technology to cold cathode technology. Circuit breakers manufactured prior to 1980 contain some asbestos material. Controlled Power offers asbestos abatement as required. Call us today for more information. Phone: 330.834.3200 Fax: 330.834.3201 www.controlledpower.com