CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

Similar documents
E-RATED/MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

Medium voltage fuses Medium voltage fuses

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Low-Peak 600V Class RK1

General Purpose US Fuses

IEC Standard Back-Up Fuse-Links

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Medium Voltage Fuses

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

Special Purpose Fuses

Mica Element Support. Compacted Quartz Sand. Length B

N0N A 250V One-Time Class H Fuse

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

FX Full-Range Current-Limiting Fuse

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

North American Power Fuses

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

T CLASS T FUSE BLOCKS

PT Medium voltage fuses for potential and small power transformers

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH Solid Blades 690 VAC sizes 000 to 3

Accessories. For product data sheets, visit

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

X-Limiter full-range current-limiting fuse

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

Application Information Need to know how? You ve turned to the right place...literally.

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

6,3* 1,6 No Printed circuitboard Brass, Nickel plated MR 5-6 Y Yes Yes 5x20 &6x32

High Speed Fuses. Section Contents Page

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Ferrule fuses. High Speed Fuses

Section Contents. Page. Introduction... 72

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Medium Voltage Metal-Enclosed Switches

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Semiconductor Fuses European Fuses

onlinecomponents.com

Product Selection Guide

R-Rated medium voltage fuses for motor circuit protection

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

R-Rated medium voltage fuses for motor circuit protection

Low voltage, branch circuit fuses

Low Voltage, Branch Circuit Rated Fuses

Medium Voltage. Section Contents. Page. Introduction...100

Product Catalog Medium Voltage Fuses. Circuit Protection

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

A. Submit manufacturer's literature and technical data before starting work.

Industrial Control Transformers

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

K-Limiter high ampere Companion II fuse

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

PROTECTION AND CONTROL

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

3.2. Current Limiting Fuses. Contents

Regenerative DC Common Bus Supply

Molded Current-Limiting Fuse

Fuse/Var Technical Data

Limitor -G General Purpose Fuses

PANELBOARDS C1/C2 SECTION 6

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Medium voltage fuses - European Fuses

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

SWITCHGEAR DIVISION PRODUCT PROFILES

Semiconductor (AC) fuses

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

High voltage current limiting Fuse links type CEF

Bussmann. Circuit Protection Solutions

Protistor size 70 gr 690VAC (IEC)

TA Ta VA CTRL-XFRMR

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

CMU medium voltage power fuses

Bulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer

Transcription:

SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced clips. They are UL listed as general purpose current-limiting fuses and are for use indoors (or outdoors in a weatherproof enclosure). The unique time-current characteristic of Ferraz Shawmut E-rated fuses allows them to be closely sized to transformer full-load rated current, as recommended by IEEE guidelines, without being affected by normal magnetizing inrush current. fuses are typically sized at transformer rated current of 133%, thereby providing superior overall protection. HIGHLIGHTS: E-Rated UL Listed 5.5kV and15.5kv Complies with ANSI C37.46 APPLICATIONS: Protection for 5.5, 8.25 or 15.5kV transformers or distribution system. Features/ Benefits UL Listed for compatiblity with UL listed equipment Ferrule mounting for standard clips and interchangeability with other brands of fuses Current Limiting for superior equipment protection Blown-fuse indicator gives positive identification of open fuse Non-venting for silent operation Metal Embossed Catalog Number and manufacturing date for lasting identification DEFINITIONS: E-rating E-rated fuses operate as follows: 100E or less - must melt in 300 seconds (5 mins.) at 200 to 240% of E (ampere) rating. Over 100E - must melt in 600 seconds (10 mins.) at 220 to 264% of E (ampere) rating. Example - A 100E fuse must melt in 300 seconds with an applied current of 200 to 240 amperes. General Purpose Current-Limiting Fuse A general purpose current-limiting power fuse is one that is capable of interrupting all currents from its rated interrupting rating down to the current that causes melting of the fusible element in one hour. Ratings A055F AC: 5E to 450E 5.5kV, 63kA I.R. Sym. A825X AC: 10E to 200E 8.25kV, 50kA I.R. Sym. A155F AC: 5E TO 200E 15.5kV, 50kA I.R. Sym. Approvals UL Listed to JEEG, Fuses Over 600 Volts UL File # E143362 Spring-Reinforced Clips for Fuses: 228-700-530 (One pair of clips) For 3 Diameter, 2 barrels max. E 2

5.5kV Ferrule Mounted Catalog Numbering System A 0 5 5 F 1 D 0 R 0-1 0 0 E Ampere Rating Revision/No. Special Features Diameter (C=2, D=3 ) No. of Barrels Style (F=Ferrule Mount) Max. Voltage Rating (055=5.5kV) Amp-trap Fuse Indicator flush with surface in Untripped Position Blown Fuse Indicator E Figure A Figure B Figure C Catalog Numbers, Ratings, Dimensions, Series, 5.5kV DIMENSIONS Inches (mm) INTERRUPTING NEW CATALOG OLD CATALOG AMPERE NUMBER OF FIG. RATING NUMBER NUMBER RATING BARRELS A B C RMS SYM.* AMPERES 5.5kV Max. Ferrule Mounted Style 12 (305mm) Clip Centers 2 (50.8mm) Barrel Diameter A055F1CORO-5E A550X5E-1B 5E 5E 7E 7E-1B 7E 10E 10E-1B 10E 15E 15E-1B 15E 20E 20E-1B 20E 1 A 14.11 2.2.19 63,000 25E 25E-1B 25E (358) (56) (4.8) 30E 30E-1B 30E Tripped 40E 40E-1B 40E Force 50E 50E-1B 50E 1 lb. 65E 65E-1B 65E 5.5kV Max. Ferrule Mounted Style 12 (305mm) Clip Centers 3 (76.2mm) Barrel Diameter A055F1DORO-10E A550X10E-1F 10E 15E 15E-1F 15E 20E 20E-1F 20E 25E 25E-1F 25E 30E 30E-1F 30E 40E 40E-1F 40E 50E 50E-1F 50E 1 B 65E 65E-1F 65E 80E 80E-1F 80E 15.88 3.0 0.5 100E 100E-1F 100E (403) (76) (13) 63,000 125E 125E-1 125E Tripped 150E 150E-1 150E Force 175E 175E-1 175E 2 lbs. 200E 200E-1 200E A055F2DORO-250E 250E-1 250E 300E 300E-1 300E 350E 350E-1 350E 2 C 400E 400E-1 400E 450E 450E-1 450E * RMS ASYM. AMPERES = RMS SYM. AMPERES x 1.6 E 3

A055F1CORO 5E to 65E Minimum Melting Time Current Data, 5.5kV Fuses Total Clearing Time Current Data, 5.5kV Fuses A055F1CORO 5E to 65E E 4

A055F1DORO 10E to 200E and A055F2DORO 250E to 450E Total Clearing Time Current Data, 5.5kV Fuses E Minimum Melting Time Current Data, 5.5kV Fuses A055F1DORO 10E to 200E and A055F2DORO 250E to 450E E 5

A055F1CORO 5E to 65E Peak Let-Thru Current Data, 5.5kV Fuses Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes A055F1DORO 10E to 200E and A055F2DORO 250E to 450E Peak Let-Thru Current Data, 5.5kV Fuses Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes E 6

SERIES E-RATED/MEDIUM VOLTAGE FUSES 8.25kV Ferrule Mounted 3 (76) 3 (76).38 (9.6) 15.88 REF (403).50 (13) 2 LB TRIP FORCE Figure A 3 (76) E.38 (9.6) 3 (76).50 (13) 2 LB TRIP FORCE 15.88 REF (403) Figure B CATALOG NUMBER AMPERE RATING NUMBER OF BARRELS FIG. INTERRUPTING RATING RMS SYM. AMPERES* 8.25kV MAX. FERRULE MOUNTED STYLE - 12 (305 mm) CLIP CENTER - 3 (76.2 mm) BARREL DIAMETER A825X10E-1 10E 1 A A825X15E-1 15E 1 A A825X20E-1 20E 1 A A825X25E-1 25E 1 A A825X30E-1 30E 1 A 50,000 A825X40E-1 40E 1 A A825X50E-1 50E 1 A A825X65E-1 65E 1 A A825X80E-1 80E 1 A A825X100E-1 100E 1 A A825X125E-1 125E 2 B A825X150E-1 150E 2 B 50,000 A825X200E-1 200E 2 B * RMS ASYM. AMPS = RMS SYM. AMPERES x 1.6 E 7

SERIES E-RATED/MEDIUM VOLTAGE FUSES A825X (10E to 200E) -1 A825X (10E to 200E) -1 Current in Amps x 10 A825X (10E to 200E) -1 Peak Let-Thru Current Data, E-Rated Fuses Maximum Instantaneous Peak Let-Thru Amperes Total Clearing Time Current Data Current in Amps x 10 Minimum Melting Time Current Data Available Current in RMS Symmetrical Amperes E 8

Current in Amps x 10 15.5kV Ferrule Mounted Indicator Flush with Surface in Untripped Position Catalog Numbering System A 1 5 5 F 1 D 0 R 0-1 0 0 E Ampere Rating Revision/No. Special Features Diameter (C=2, D=3 ) No. of Barrels Style (F=Ferrule Mount) Max. Voltage Rating (155=15.5kV) Amp-trap Fuse Blown Fuse Indicator E Figure A Figure B Figure C Catalog Numbering System, Ratings, Dimensions, Series, 15.5kV (mm) INTERRUPTING DIMENSIONS Inches NEW CATALOG OLD CATALOG AMPERE NUMBER OF FIG. RATING NUMBER NUMBER RATING BARRELS A B C RMS SYM.* AMPERES 15.5kV Max.. Ferrule Mounted Style 15 (381 mm) Clip Centers 2 (50.8mm) Barrel Diameter A155F1CORO - 5E A1550X - 5E-1B 5E 7E 7E-1B 7E 10E 10E-1B 10E 1 A 17.03 2.2.19 50,000 15E 15E-1B 15E (433) (56) (4.8) 20E 20E-1B 20E Tripped 25E 25E-1B 25E Force 30E 30E-1B 30E 1 lb. 15.5kV Max.. Ferrule Mounted Style 15 (381mm) Clip Centers 3 (76.2mm) Barrel Diameter A155F1DORO - 10E A1550X - 10E-1F 10E 15E 15E-1 15E 20E 20E-1 20E 25E 25E-1 25E 1 B 18.87 3.0 0.5 50,000 30E 30E-1 30E (479) (76) (13) 40E 40E-1 40E Tripped 50E 50E-1 50E Force 2 lbs. A155F2DORO - 65E 65E-1 65E 80E 80E-1 80E 2 C 100E 100E-1 100E 15.5kV Max.. Ferrule Mounted Style 18 (457mm) Clip Centers 3 (76.2mm) Barrel Diameter A155F1DORO - 65E A1550X - 65E-1D 65E 80E 80E-1D 80E 1 B 21.75 3.0 0.5 50,000 100E 100E-1D 100E (552) (76) (13) Tripped A155F2DORO- 125E 125E-1D 125E Force 150E 150E-1D 150E 2 C 2 lbs. 175E 175E-1D 175E 200E 200E-1D 200E * RMS ASYM. AMPERES = RMS SYM. AMPERES x 1.6 E 9

A155F1CORO 5E to 30E Minimum Melting Time Current Data, 15.5kV Fuses A155F1CORO 5E to 30E Total Clearing Time Current Data, 15.5kV Fuses E 10

A155F1DORO 10E to 50E and A155F2DORO 65E to 100E Total Clearing Time Current Data, 15.5kV Fuses E Minimum Melting Time Current Data, 15.5kV Fuses A155F1DORO 10E to 50E and A155F2DORO 65E to 100E E 11

A155F1DORO 65E to 100E and A155F2DORO 125E to 200E Minimum Melting Time Current Data, 15.5kV Fuses A155F1DORO 65E to 100E and A155F2DORO 125E to 200E Total Clearing Time Current Data, 15.5kV Fuses E 12

A155F1CORO 5E to 30E A155F1DORO 10E to 50E A155F2DORO 65E to 100E Peak Let-Thru Current Data, 15.5kV Fuses Peak Let-Thru Current Data, 15.5kV Fuses Maximum Instantaneous Peak Let-Thru Amperes Maximum Instantaneous Peak Let-Thru Amperes E Available Current in RMS Symmetrical Amperes A155F1DORO 65E to 100E A155F2DORO 125E to 200E Peak Let-Thru Current Data, 15.5kV Fuses Available Current in RMS Symmetrical Amperes Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes E 13