Flowmeter DFM

Similar documents
Diaphragm valve MV 309

Ball valve C 200 PROP / C 200 DOS

Technical Data. Flow Meter Schwertberg, Poneggenstr. 5 Austria/Europe Fax +43/7262/ Tel.

Angle Seat Valve SV 300

Modular valve block MVB 100/200

Diaphragm Valve MV pneumatic - with pneumatically directly controlled actuator

Diaphragm Valve MV 310

Flowmeter, Plastic 805 / 807 / 815 / / 825 / 832 / 835. Sectional drawing

Wafer check valve RSK 500

Strainer SF 305. Sealing FPM EPDM

KM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation

/ 855 / 857 / 861 / / 870 / 875 / 880 / 885. Variable Area Flowmeter, Plastic

Flowmeter, Plastic 855 / 857 / 865 / / 875 / 880 / 885

Wafer check valve RSK 500

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Pressure relief valve DHV 718

Ball Valve C 200. Stem PVC-U PVDF PP, fiberglass-reinforced. Ball PVC-U PP PVDF. Ball Seat PTFE. Application chemical and industrial plants

Variable area flowmeter DFM 165 to 350

Pressure relief valve DHV 712-R set range: 0,3-10,0 bar

Ball valve C 100 multi-part, high k v value, high stability

2 way ball valve S4 with integrated Praher Labeling System

Ball Valve C 110. PVC-U PP PVDF - wafer flange socket end DIN-flange. Ball. Advantages. Ball seat. Application. Sealings. Utilisation.

3 way ball valve S4 hand operated

R677. Diaphragm Valve, Plastic

Variable Area Flow Meters

Diaphragm valve T4 [hand operated]

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

C 200 Modern Construction. Flexible Modular Design. Highest Safety.

Ball valve C 10 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16. Nominal size DN Nominal size 2 6 Nominal pressure PN 6 10 bar.

Thermoplastic Vertical Sump Pump Type ETL

R690. Diaphragm Valve, Plastic

Plastic tube variable area flowmeter for liquids and gases

Diaphragm pressure gauge guard MDM 902 corrosion-free pressure transmission for aggressive media

Diaphragm Valve MV 309

600, 630. Diaphragm Valve, Plastic

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Diaphragm valve, Plastic

N086, N186, N786. Pressure retaining valve, Plastic

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Ball valve C 100 multi-part, high k v value, high stability

485 - NC NO/DA DN

GEMÜ R680 Motorized diaphragm valve

PNEUMATICALLY ACTUATED 2-WAY

Vertical Sump Pump Type ETL

Solenoid valve type 150 direct action

Ball valve C 100 multi-part, high k v value, high stability

INSERTION Adaptor for analysis

2 way ball valve S4 with pneumatic actuator

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

INSERTION flow sensor for continuous flow measurement

Diaphragm Valve, Plastic

Pressure Reducing Valve V782

Diaphragm Valve, Plastic

Insertion magnetic inductive flowmeter

Ball Valve C 200. Stem PVC-U PVDF PP, fiberglass-reinforced. Ball PVC-U PP PVDF. Ball Seat PTFE. Application chemical and industrial plants

Inductive conductivity meter

Visual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Material Pipe Operating Operating Page

GEMÜ 717 Manually operated ball valve

Datasheet Pressure Reducing Valves V782/V82/V182

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

VR DN PVC-U. Check valve

Diaphragm Valve, Plastic

Butterfly Valve K 220 for application in the harsh environment of the chemical industry

Diaphragm Valve, Plastic

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Praher S4 Ball Valve. manual valves. Praher Type S4 Ball Valve. Materials. Size. Pressure Rating. Features. Connections.

Diaphragm Valve, Plastic

FK DN PVC-U Butterfly valve

GEMÜ 205 Electrically operated solenoid valve

i butt weld spigot i flanged end acc. to DIN PN 10 / 16

Inline Paddle Wheel Flow Switch

Hygienic butterfly valves VZFB

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

GA 24 Heavy-duty variable area flowmeter

Ultra Proline. ECTFE (Halar ) Single Wall Piping System

AV 23 Balancing valves SETTER Inline

Pressure Relief Valve Overflow Valve Type DHV 715 Type DHV 716 Type DHV 725

Hygienic Butterfly Valve VZFA Product range overview

Diaphragm Valve, Plastic 2/2 way, motorized

High Purity PVDF/PP Valves and Flowmeters

710, 717, 723. Ball Valve, Plastic

INSERTION flowmeter with paddle wheel, ELEMENT design

GEMÜ 710 Pneumatically operated ball valve

Diaphragm Valve, Plastic

Assembly and operating Instructions RA 60 / FA 60

DK/CP DN PVC-U / PVC-C / PP-H / PVDF. Pneumatically actuated 2-way diaphragm valve

Process Multi-Rheo Filter PMRF

Inductive conductivity meter

2 way ball valve M1 with pneumatic actuator

DIN /DIN Aseptic Flange Union for DIN 11866/11850 Tube

CEPEX PLASTIC VALVES EXTREME SERIES

Angle Seat Globe Valve, Metal

Installation and Operating Instructions. Variable area flow meter RA 65 / FA 65

K-Factor. Global Installation Fittings and K-Factors. Global

FK DN PVC-U. Butterfly valve

VKD DN PP-H. DUAL BLOCK 2-way ball valve

Metal tube variable area flowmeter for gases, liquids and steam

Transcription:

Flowmeter DFM 165 50 Nominal size DN 10-65 Nominal size /8 2 1/2 Nominal pressure PN 10 bar Features Measuring range to 50,000 l/h suitable for a wide range of applications for gaseous medium types, water, lyes, acids direct visualisation of the measured values accuracy class 4 integrated mounting rail for flow data sensors Additional options on request Free of paint wetting impairment substances Flow data sensor special scales Note Flow data sensor only in combination with magnetic float PA PVC-U PSU PVDF www.asv-stuebbe.com/products/instrumentation

Optional: Magnetic PVDF Float Standard: PVDF Float Optional: DFM with Special Scale Standard: DFM with H 2 O Scale Float Scales PA PVC-U PSU PVDF Sealing Connection 1 2 EPDM* / FPM Socket 4 5 6 EPDM* / FPM Spigot 7 7 8 EPDM* / FPM Flange * PVDF-Flowmeter only available with FPM Seal available not available Basic Nominal Sizes: DN 8 DN 10 DN 15 DN 20 DN 25 DN 2 DN 40 DN 50 DN 65 DN 80 DN 100 DN125 DN 150 DN 200 DN 250 DN 00 DN 50 DN 400 Connection Material (process connection) 1 2 PVC-U socket DIN, ANSI, BS, JIS*. female thread Rp. 1.4571 male thread R.* female thread Rp. MS female thread Rp. PP socket DIN PVC-U socket DIN, ANSI, BS, JIS*. female thread Rp. 1.4571 male thread R.* female thread Rp. MS female thread Rp. PP socket DIN. female thread Rp.* PVDF socket DIN 4 5 6 7 8 PE spigot DIN (95mm).** PP spigot IR PP spigot IR.** PE spigot DIN (95mm).** PVDF spigot IR.*** PP-St. flange DIN, ANSI.** GFK flange DIN.** PP-St. flange DIN, ANSI.** * available up to DN 50. ** available from DN 15. *** available in DN 15-50. 2

Type DFM 165 DFM 170 DFM 185 DFM 200 DFM 50 d (mm) 16 20 25 2 2 40 50 6 75 DN (mm) 10 15 20 25 25 2 40 50 65 DN (inch) /8 1/2 /4 1 1 1 1/4 1 1/2 2 2 1/2 Measuring range (l/h) 10.000 50.000 2.500 25.000 1.500 15.000 1.000 10.000 600 6.000 400 4.000 00.000 250 2.500 200 2.000 150 1.500 100 1.000 60 600 40 400 25 250 15 150 10 100 5 60 5 50 24

Application Measurement of the flow in pipe systems with visual display of the measured values Use Chemical plant manufacture Water treatment Function The medium water, air, fluid or gaseous chemicals flows vertically through the flowmeter from the bottom to the top. The float is lifted with no friction by the flow forces and directly indicates the flow volume specified on the measuring tube scale with its top read-off edge (maximum diameter). The measuring tube contains the float, made of PVDF as a standard, as well as the float trap. Version Equipped with measuring range scale l/h for water 20 C as a standard. two displaceable set-point value indicators floats made of PVDF, optionally with magnet optionally flow data sensors ZE 000/075 for process automation for continuous measuring optionally limit reed switches ZE 950/ZE 951 for electric signalling of min./max values Measuring range see measuring range overview Measuring accuracy Class 4 according to VDI/VDE 51, page 2 VDI = Verein Deutscher Ingenieure (Association of German Engineers) VDE = Verband Deutscher Elektrotechniker (Association for Electrical, Electronic & Information Technologies) Flow medium Technically pure, neutral or aggressive fluid or gaseous medium types, provided that the valve components coming into contact with the medium are resistant at the operating temperature according to the ASV resistance guide. Operating note A PVC-U measuring tube cannot be used for gaseous medium types. Flow direction from bottom to top ASV resistance guide www.asv-stuebbe.de/pdf_resistance/00051.pdf Viscosity for medium types differing from H 2 O DN 10 40: maximum 200 50 mpa DN 50 65: maximum 500 mpa Process temperature see pressure/temperature diagram Process pressure see pressure/temperature diagram Nominal pressure (H 2 O, 20 C) PN 10 bar Size DN 10-65 Device connection measuring tube made of PVC-U, PA, PSU: DIN 806 union with union socket ends for solvent welding DIN ISO (PVC-U) measuring tube made of PVDF: union (special thread) with union socket end for fusion welding DIN ISO (PVDF) On request: union end with female thread (GTW/VA) union socket end for fusion welding DIN ISO (PP/PE) on request 4

Material with medium contact Measuring tube: PA PVC-U PSU PVDF Float: PVDF without magnet PVDF with liquid-tight sealed magnet for electronic measurement Insert/stop: PVDF Sealing: FPM EPDM Union nut/union ends: PVC PP PVDF Material, no medium contact Set-point indicator: PE Mounting position vertical Accessories Special scales for: Medium air (Nm /h) at 20 C and 0- bar Medium NaOH (l/h) at 0 C Medium HCl (l/h) at 0/50 C Medium FeCl (l/h) at 40 41 C Medium US GPM further special scales on request Flow data sensors ZE 000/ZE 075 for process automation optionally limit reed switches ZE 950/ZE 951 for electric signalling of min./max values 5

Pressure/temperature diagram Description P Operating pressure T Temperature 1 Measuring tube 2 Connection The pressure/temperature limits of the materials are applicable for the stated nominal pressures and a computed operating life factor of 25 years. The values are a guide for flow medium types (DIN 240) to which the valve material is resistant. For other flow medium types please refer to the ASV resistance guide; reduction ratios may have to be taken into account. The operating life of the wear parts depends on the conditions of use. The rated pressure (PN) depends on the size and material of the measuring tube/connection. 6

Conversion of flow rate units m /s m /h l/min GPM (GB) GPM (US) ft /s 1 m /s 1 600 60 000 1 198 15 850 6. 1 m /h 2.788 10 4 1 16.667.66 4.405 9.80 10 1 l/min 1.667 10 5 6 102 1 0.219 0.264 0.16 1 GPM (GB) 7.577 10 5 0.27 4.55 1 0.8 2.676 10 1 GPM (US) 6.09 10 5 0.227.78 1.20 1 2.225 10 1 ft /s 2.8 10 2 102 1700 7.69 444.44 1 Pressure loss values DFM 165 50 d (mm) DN (mm) DN (inch) Δp water 20 C (mbar) Δp air 20 C (mbar) DFM 165 16 10 /8. 4.8 DFM 170 20 15 1/2 2.5 4. DFM 185 25 20 /4 6.1 8. DFM 200 2 25 1 6.1 8. DFM 50 2 25 1 12. 15.9 40 2 1 1/4 12. 15.9 50 40 1 1/2 12. 15.9 6 50 2 22.2 27.1 75 65 2 1/2.7 40.0 7

Connection socket Type DFM 165 DFM 170 DFM 185 DFM 200 DFM 50 d (mm) 16 20 25 2 2 40 50 6 75 DN (mm) 10 15 20 25 25 2 40 50 65 DN (inch) /8 1/2 /4 1 1 1 1/4 1 1/2 2 2 1/2 G* /4 1 1 1/4 1 1/2 1 1/2 2 2 1/4 2 /4 1/2 L 165 170 185 200 50 50 50 50 50 L1 171 176 191 206 56 56 56 56 56 all dimensions in mm / * dimensions in inch 8

Components DFM 165-200 Components DFM 50 1 2 1 2 4 5 6 4 5 6 Position Designation 1 Union nut 2 Union end Insert/stop 4 Float 5 Set-point indicator 6 Measuring tube Position Designation 1 Union nut 2 Union end Insert/stop 4 Float 5 Set-point indicator 6 Measuring tube 9