Solenoid Valve Output Module IC693MDL760 Product Description

Similar documents
This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

Discrete Output Modules IC697MDL753

Redundant Control System

4 Redundant Control System

EVP SERIES PROPORTIONAL CONTROL VALVES

CIRCLE SEAL CONTROLS

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

Installing Power Components

PNEUMATIC MANIFOLD VALVE PMV08

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

HL (AZH) LIMIT SWITCHES

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

CIRCLE SEAL CONTROLS

Vacuum / Release Unit

3/2-way Rocker Solenoid Valve for pneumatic systems

Series 581 ISO Pneumatic Directional Control Valves

8BVE0500HW General information. 2 Order data 8BVE0500HW

DE- OUT OUT DE- OUT OUT DE- SERIES MODEL E21 2-WAY NORMALLY OPEN CONDUIT HOUSG (700) 235 (0) 1 (3) (1) (700) 235 (0) 1 (3) (1) E21G7XC

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Power Supplies PSS Series

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

DME Valve Gate Controls

Application Description

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Electrical: Valve monitoring and control circuits

Holding. Resistance. Inrush. Watts. Amps. Amps. (ohm)

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

Remote Process Actuation Control System AirLINE - Siemens ET 200S

92 Series MAConnect with Sub D

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Microprocessor Controlled Dental Vacuum System Installation Manual

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Induction Power Supplies

VersaPoint* I/O System

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Installation, Operation and Maintenance Manual

Illustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32

Vission 20/20 Retrofit Instructions

EI, EIO INTRINSICALLY SAFE VALVES

Installation Instructions

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

10 MM MINIATURE VALVES

80V 300Ah Lithium-ion Battery Pack Data Sheet

82 Series MAConnect with Sub-D

AGV5-1, AGV5-2 FORM AGV5 OM 11-02

Industrial Control Transformers

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

Easytork Solenoid Valve IOM

AS-i Metal Enclosed DOL Starters

Control & Power, Inc

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

CYCLOPS Z Purge Indicator

SECTION B: SYSTEM OPERATING COMPONENTS

Valves, Fittings, and Manifolds Catalog. We make things MOVE

GE Programmable Control Products. PACSystems* RX3i Rackless Energy Pack IC695ACC403 Quick Start Guide. GFK-3000 December 2016

Prism PI Intelligent features offer advanced performance

Continental Hydraulics Installation Manual CEM-AA-A

AirLINE and AirLINE Quick electrical/pneumatic Automation System

SECTION B1: MACHINE COMPONENTS

High Frequency SineWave Guardian TM

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

WF-5100 Series True Sine Wave Inverters

2005 / 2012 / 2035 Series

On-off Valves MS-EE, Inch Series Overview

Pressure Regulators MS-LR, Inch Series Overview

Operators Manual ECO-AIR-IVS Internal Valve Actuation System

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

CYCLOPS Y Purge Indicator

Troubleshooting Bosch Proportional Valves

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

Adjustment range. Seal material. Pressure connection

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

IMTS 2012 Valve Control

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

AF40... AF96 3-pole contactors Technical data

EI, EIO INTRINSICALLY SAFE VALVES

Installation, Operating and Maintenance Manual

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

PRODUCT SPECIFICATION

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

Product Information ROSS CONTROLS

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

HIGH POWER SOLENOID DRIVER 1

Pressure Transmitters

CYCLOPS Z Purge Indicator

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Installation Instructions

Valve terminal VTUG-...-M/VTUG-...-V

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

Modular pneumatic valve unit

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

EC-3000/3400 Solid State Rotary Cam Limit Switch Installation/Operation Manual

Transcription:

GFK-A November 000 Solenoid Valve Output Module ICMDL0 Product Description Description This ICMDL0 output module provides eleven pneumatic outputs and five VDC sourcing outputs. For each pneumatic output, the module contains an internal - way solenoid-actuated valve and an associated output fitting, which is located on the front panel. When an output is turned ON, its internal valve connects a usersupplied pressure source (00 psi maximum) to the output fitting. The pressure source is connected to the fitting on the bottom of the module. When the output is turned OFF, the valve s output port is vented to atmosphere inside the module. Solenoid power is supplied from an external VDC source to the DC Outputs connector on the front panel. A -pin connector, located on the module s front panel, allows the user to connect the optional ICACC0 Solenoid Forcing Pendent, described later. The five VDC outputs can each drive up to a maximum 0.A, with a limit of.0a total for all five points. Field wiring is connected to these outputs via a 0-pin connector located on the front panel. The user must provide VDC to this connector to power the positive logic outputs, which source current to the field connections. This group of five discrete outputs is electrically isolated from the PLC backplane; however, the outputs are not individually isolated from each other. The module is accessed from the logic program as a standard -point output module. When using VersaPro version.0 (or later version) programming software, it should be configured by its catalog number. When using programming software other than VersaPro version.0 (or later version), the module must be configured as a standard -point generic output module. 0 PWR 0 Solenoid Valves DC Outputs DC Outputs Pendent Figure. ICMDL0 Module The module is enclosed in a standard IC plastic housing.

Solenoid Valve Output Module GFK-A Module Specifications Table. Module Specifications Pneumatic Outputs Outputs per Module Module Specifications (grouped) Thermal Derating Refer to Table Supply Pressure Pressure Drop External Solenoid Power Isolation Solenoid Inrush Current Solenoid Holding Current ON Response Time OFF Response Time Maximum Solenoid ON Time Output Fitting Supply Fitting LED Indicators for output points LED PWR Indicator 00 psi max. psi max.@ 0.scfm.-.VDC, VDC nominal 00 volts between field side and logic side; 00 volts between groups ma/valve @ VDC ma/valve @ VDC ms max. ms max. 0 days max. (must be turned OFF at least once every 0 days) Threaded for 0- adapter, / hose barb provided Threaded for 0- adapter, / hose barb provided One LED per output point indicates ON/OFF state LED indicates solenoid power is present DC Outputs Outputs per Module Thermal Derating Output Voltage Isolation Continuous Load Current Inrush Current Voltage Drop Leakage Current ON Response Time OFF Response Time Protection (each output) LED Indicators (grouped) None -0VDC, VDC nominal 00 volts between field side and logic side; 00 volts between groups 0.A @ 0VDC per point,.0a total for all five points.0a for 00ms 0.V max ma @ 0VDC max ms max. ms max. No internal fuse One LED per output shows on/off state Module Characteristics Operational Ambient Temperature Backplane Current C ( F) max. ma from V bus (solenoid LEDs are powered from external power source)

Solenoid Valve Output Module GFK-A Environmental Requirements and Solenoid Valve Output Thermal Derating Table. Environmental Requirements Parameter Min. Max. Units Storage Temperature 0 Degrees C Operational Ambient temperature 0 Degrees C Note This module has a lower operating temperature rating than standard IC I/O modules. Table. Solenoid Valve Output Thermal Derating Ambient Temperature Solenoid Valve Output Rating (with DC Outputs Operating at Continuous Load Current Rating) 0 C ( F) All pneumatic outputs may be on continuously 0 C (0 F) Six pneumatic outputs may be on continuously C ( F) Four pneumatic outputs may be on continuously Note ICMDL0A does not have CE or UL approvals/listings. ICMDL0B (and later versions), when available, will have CE and UL approvals/listings. Optional ICACC0 Solenoid Forcing Pendent The ICACC0 Solenoid Forcing Pendent is an optional system maintenance tool. This pendent is a small hand-held unit containing eleven switches, one for each valve. Each switch is labeled to allow the user to easily establish a correlation between any given switch and its corresponding valve. The pendent is attached to the Solenoid Valve Output Module via the -pin connector, labeled Pendent, on the module s front panel. With solenoid power applied (to the DC Outputs connector), the user may turn the solenoids ON and OFF with the pendent switches. This pendent is intended to allow maintenance personnel to operate the valves during shut down periods when the main power to PLC system has been turned off. If the pendent is attached during normal operation (with the PLC system running), a command from the PLC can turn a valve ON even if the pendent switch for that valve is in the OFF position, and a pendant switch can turn a valve ON even if the PLC is commanding it to be OFF. LED Operation This module has LED indicators (see Figure ): Solenoid Power - LED, labeled PWR, indicates presence of solenoid power. Point Status - LEDs, labeled - and -, indicate individual I/O point ON/OFF status. The solenoid valve status LEDs (the top group, labeled to ) are powered from the VDC external Solenoid Power source; these LEDs will not illuminate unless this power source is present. The PWR LED indicates the presence of external solenoid power. Each valve status LED illuminates while its corresponding valve is open (valve coil is energized), whether by PLC command or by use of the Solenoid Forcing Pendent. The discrete output LEDs (the bottom group, labeled to ) are powered from the PLC backplane and can illuminate even if the external DC Output field power (VDC) is off.

Solenoid Valve Output Module GFK-A Field Wiring Two AMP brand.0 square double-row.00 X.00 shrouded male pin headers provide the field connection to the five VDC discrete outputs and the Solenoid Forcing Pendent. These connectors have detent windows to retain the mating field connector. The field connectors are not supplied with the module; however, the optional pendent comes with cable and connector. See the next section, Field Connectors, for specifications. Table. Pendent Connector Pin Assignments Pin Connection Number* Output Point (Solenoid ) Output Point (Solenoid ) Output Point (Solenoid ) Output Point (Solenoid ) Output Point 0 (Solenoid 0) Output Point (Solenoid ) Output Point (Solenoid ) Output Point (Solenoid ) Output Point (Solenoid ) 0 Output Point (Solenoid ) Output Point (Solenoid ) Solenoid Power Common * Connector numbering was changed in version A of this data sheet to meet a customer requirement. This did not involve any physical changes to the module. 0 View: Looking at Front of Module Table. DC Output Connector Pin Assignments Pin Connection Number* External Solenoid Power COM Output Point (DC Output ) Field Power +VDC (for DC Outputs) Output Point (DC Output ) Output Point (DC Output ) External Solenoid Power +VDC N/C Field Power Common (for DC Outputs) Output Point (DC Output ) 0 Output Point (DC Output ) * Connector numbering was changed in version A of this data sheet to meet a customer requirement. This did not involve any physical changes to the module. 0 View: Looking at Front of Module

Solenoid Valve Output Module GFK-A Field Connectors The following specifications are for the mating connectors (not supplied with the module) for the module s two faceplate connectors ( Pendent and DC Output ). Pendent Connector (Supplied with Optional Pendent) Item Vendor Part Number Note Male Housing AMP - -pin connector housing Crimp Contacts ( required) AMP -- Female pins, rated for AWG 0- gauge wire Crimping Tool AMP 00- DC Output Connector Item Vendor Part Number Notes Male Housing AMP - 0-pin connector housing Crimp Contacts (0 required) AMP -- Female pins, rated for AWG 0- gauge wire Crimping Tool AMP 00- Pneumatic Fitting Specifications and Installation Instructions Module Fitting Number per Module Vendor Part Number Notes Front Clippard - 0- threads, / hose barb, / hex. shoulder Bottom Clippard - 0- threads, / hose barb, / hex. shoulder Due to limited room in the module s packing container, it is necessary to ship the module with its fittings removed. Use the following guidelines to install the fittings on the module: Place the provided gasket over the threaded end of the fitting and carefully push it over the threads until it stops against the hexagonal shoulder. Carefully thread the fitting into the manifold by hand. Tighten the fitting to a maximum of to inch/pounds. Caution Overtightening may cause a fitting to crack or snap off, or could result in thread damage. Limit tightening torque to to inch/pounds.

Solenoid Valve Output Module GFK-A Pneumatics Installation and Safety Requirements Since the ICMDL0 module s internal valves exhaust inside the module, it is important that you adhere to the following guidelines: Compressed air or other inert gas used in the module s valves must be clean and dry. No water, oil, or other contaminants can be tolerated in the air/gas stream. The presence of these will cause module failure and possible damage to surrounding components. Only clean, dry, compressed air or inert gas may be used. Use of an explosive or flammable gas will result in explosion or fire if used with this module. The module should not be used in an airtight, unvented cabinet. Use in an airtight cabinet could result in the cabinet becoming pressurized, which could lead to personal injury and equipment failure. Warning Failure to follow the above Pneumatics Installation and Safety Requirements can result in personal injury, module failure, and damage to associated equipment. Compatibility Hardware This module is a standard size IC module, compatible with all IC series CPUs and baseplates. It will function in any CPU, Expansion, or Remote baseplate. Software When configuring this module with VersaPro version.0 (or later version), it should be configured by its catalog number. When configuring with programming software other than VersaPro version.0 (or later version), the module must be configured as a standard -point generic output module. Scan Time Contribution This module has the same scan time contribution rating as a standard -point output module, as specified in the I/O Scan Time Contribution tables in Chapter of the IC PLC CPU Instruction Set Reference Manual.