Hi-Rel HOLD-UP MODULE HUGD-50 : 50W POWER. Hold-Up Solution 9-36V & 16-40V DC/DC Converter Compatible Metallic Case. 1-General. 2-Product Selection

Similar documents
DC/DC CONVERTER Designing Battery Charger

S24SP series 40W Single Output DC/DC Converter

S24SP15004 series 60W Single Output DC/DC Converter

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

PG02S Series 2W DC/DC CONVERTER, SIP-Package

(typ.) (Range) ±18 330# 89 MPW MPW

Series AM1P-Z 1 Watt DC-DC Converter

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Series AM5T-Z 5 Watt DC-DC Converter

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

(typ.) (Range) Load

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

SH01S/D Series 1W DC/DC CONVERTER, SMD-Package

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Series AM2D-Z 2 Watt DC-DC Converter

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

Series AM2D-Z 2 Watt DC-DC Converter

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

2W, Low Cost DIP, Dual Output DC/DC Converters

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

UL Certified RP30-FW

American Power Design, Inc.

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

DCMCW60 SERIES FEATURES

HBC DC-DC Series Data Sheet 300-Watt Half-Brick Converters

APPLICATIONS: AVAILABLE OPTIONS

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

Series AM2S-Z 2 Watt DC-DC Converter

American Power Design, Inc.

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Features. Description. Table of Contents

NOT RECOMMENDED FOR NEW DESIGNS

DVFL2800S Series HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION FEATURES

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Series AM2D-RZ 2 Watt DC-DC Converter

DH50 SERIES. DATASHEET Rev. A

Series AM2F-Z 2 Watt DC-DC Converter

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

NME 5V & 12V SERIES. Technical enquiries tel: +44 (0) Isolated 1W Single Output DC/DC Converters

IND065BLV Hornet: Non-Isolated DC-DC Voltage Regulator Modules

Silvertel. Ag Features. 2. Description. 57V Boost Converter Module. Small package. Suitable for IEEE802.3af and IEEE802.

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

C B. Operating up to 5000m altitude 5 year product warranty Models

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

SELECTION GUIDE. Input Voltage (V) Order code B0505XS-2W B0505XD-2W B0509XS-2W

NME 5V & 12V Series Isolated 1W Single Output DC/DC Converters

Series AM1G-NZ 1 Watt DC-DC Converter

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

RS5/RD5-R10/RD10. RoHS. 1.0W Regulated Single & Dual Output

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

NKE Series. Isolated Sub-Miniature 1W Single Output DC/DC Converters FEATURES

SELECTION GUIDE. Nominal Input Order Code Voltage. Output Voltage. Reflected ripple current

DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Application Note TES 1 Series

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

CMR Series Isolated 0.75W Single and Dual Output Isolated DC/DC Converters

SELECTION GUIDE - SINGLE OUTPUT 1. Nominal Input Voltage Output Voltage

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Reflected ripple current. Case Temperature rise above ambient ABSOLUTE MAXIMUM RATINGS

Unit/Comments. %; Equal Output Loads %; Equal Output Loads Full Load

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

RCD15W Series PART NUMBER STRUCTURE

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

NOT RECOMMENDED FOR NEW DESIGNS

Note1: Efficiency is tested by nominal Vin, full load and at 25 C. Package (3) CTRL Logic (2)

SELECTION GUIDE. Nominal Input Voltage. Voltage. Output. Order Code. Voltage range. Reflected ripple current. Isolation test voltage

SELECTION GUIDE. Nominal Input Voltage. Output Current. Output Voltage. Reflected ripple current

SELECTION GUIDE. 2Input Voltage. Order code (V) B0505XD-1W B0509XD-1W

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost

MTC2 Series Isolated 2W SM 2:1 Input Single Output DC-DC Converters

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

WATT MBH SERIES DC/DC CONVERTERS

NMH Series Isolated 2W Dual Output DC/DC Converters

RV-1805-C3 Application Note

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

Delphi D12S Non-Isolated Point of Load

Efficiency(1) Max. Capacitive. Package(3) CTRL Logic(2) Single

DC/DC Converter URF48_QB-75W(F/H)R3 Series

Switching Power Supplies

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Transcription:

HOLD-UP MODULE HUGD-50 : 50W POWER Hold-Up Solution 9-36V & 16-0V DC/DC Converter Compatible Metallic Case Unique Product for Hold-Up Solution Reduce Capacitance by 80% High efficiency (98%) Power range : from W to 50W Compatible with 9-36 or 16-0 Converter Include monitoring signals Programmable inrush current limitation 1-General RoHS or Leaded process option The GAIA Converter Hold up device HUGD-50 provides a state-of-the-art solution to the problem of maintaining electronic system in operation during input bus drop-out for enough time. Usually this approach uses very large capacitors because they are only charged at the voltage at which power fails. The Gaïa Converter HUGD-50 module provides an alternative solution to reduce the amount of capacitance needed by charging the hold up capacitor at a high voltage (typically 38V) while limiting the input current. The HUGD-50 must be connected between the line source and DC/DC modules. If an EMI filter and /or a pre-regulator are used, the HUGD-50 is connected between them and the converters. Basically the HUGD-50 charges the external capacitor to 38V while powering the DC/DC converters. If the power fails, the HUGD-50 generates a signal and the converters are powered from the external capacitor. The HUGD- 50 can be used either with 16-0V or 9-36V input voltage DC/DC converters since the «power fail voltage» is externally adjustable by the user between 8.8V and 15.3V. The HUGD-50 features 3 modes of operations: Charging operation mode : when the input voltage ramps-up and reaches the startup charge threshold (which is set at 1Vdc above 2-Product Selection the «power fail voltage»), the HUGD-50 begins to charge the external capacitor at 38 while powering the dc/dc converter. The charging current is controlled and externally adjustable between 100mA and 2A by a resistor. The capacitor charging time depends on the charging current. When the capacitor voltage reaches 35V, the signal (active low, open-drain) «capacitor charged» is activated and the HUGD-50 enters in the normal operation mode. Normal operation mode : in normal operation mode when the capacitor is charged and the input bus is between the «output power fail» and 0, the HUGD-50 only consumes power to keep the capacitor charged (i.e.less than 1W). The voltage drop between input and output is lower than 150mV in the worst case (50W power and 9 input voltage) The HUGD- 50 will operate indefinitely in this state until the input voltage drops below the «power fail voltage» threshold. Power fail mode : when the input voltage drops below the «power fail voltage» threshold, a «power fail» signal is activated and the HUGD-50 disconnects input from output and connects the hold-up capacitor to the output. At this point the DC/DC converters are powered by the capacitor. When its voltage finally discharges to a value slightly above the «power fail voltage» threshold value, a «capacitor discharged» flag is activated. HUGD - 50 - / option suffix Options : Suffix : /T : option for -55 C start up operating temperature nothing : RoHS process /S : option for screening and serialization -L : leaded process (available in N. America) REDEFINING THE SOURCE OF POWER Gaia Converter FC97-027.0/12 Revision L

3- Block Diagram The HUGD-50 module includes 3 main circuits : an input monitoring circuit an hold-up charger circuit a hold-up monitoring circuit Input monitoring Circuit : The input monitoring circuit monitors the value of the input bus voltage and compares it to the power fail threshold voltage (Vth) set externally through a resistor. Depending on this comparison, the circuit enables the activation of the hold-up switch or the hold-up charger and generates an open-drain «power fail flag (PF)». Hold-up Charger : The hold-up charger is used to feed the hold-up capacitor with a constant Vc=38V voltage. The design of this charger has been optimized to minimize the input inrush current which can be set externally through the Vcl input by a resistor. Hold-up monitoring Circuit : The hold-up monitoring circuit monitors the charging status of the hold-up capacitor. The circuit generates 2 open-drain flags : the capacitor charged flag (CC) and the capacitor discharged flag (CD). These flags can be used at system level for power interruption management (VME system, PCI,...). The following diagram represents the HUGD-50 series block diagram. Vi HUGD-50 Block Diagram Vo Vth Input Monitoring Vcl Hold-up Charger Vc PF CC Hold-up Monitoring CD Gi Gaia Converter FC97-027.0/12 Revision L 2

- Electrical Specifications Data are valid at +25 C, unless otherwise specified. Parameter Conditions Limit or typical Units HUGD-50 Input Permanent input voltage range (Ui) Transient input voltage Power fail voltage threshold (Vfail) Power fail voltage threshold (Vfail) Full temperature range Full load Full temperature range Full load with the setting Vth unconnected with the setting Vth connected to ground 9 0 /ms 50/100 Typical Typical 15 15,3 15,6 8,6 8,8 9 Power fail hysteresis / Typical 1 Input current consumption during charging at 28V min: Vcl unconnected max: Vcl connected to ground A A 0,1 1,5 Input current consumption during charging at 16V min: Vcl unconnected max: Vcl connected to ground A A 0,1 2,2 Output Output power Output current Full temperature range Full load Full temperature range Ui min. to max. W 50 A 5,6 Dissipated power Vin @ 9V, full power W 2 Voltage drop input/ouput Vin @ 9V, full power mv 160 Capacitor charged signal (CC) threshold Turn off threshold Turn on threshold Typical Typical 30,5 35 Capacitor discharged signal (CD) threshold with setting Vth unconnected 15,9 16,7 Capacitor discharged signal (CD) threshold with setting Vth connected to ground 9, 10,2 CC, CD, PF sink current / ma 25 Admissible hold-up capacitor / µf µf 70 30 000 Hold-up time at 50W load Vth unconnected Vth connected to ground µs/µf µs/µf 11,2 12,8 Hold-up time at 10W load Vth unconnected Vth connected to ground µs/µf µs/µf 55,6 6, Gaia Converter FC97-027.0/12 Revision L 3

5- Switching Frequency Parameter Conditions Limit or typical Specifications Switching frequency Full temperature range Ui min. to max. No load to full load Nominal, fixed 200 KHz 6- Isolation Parameter Conditions Limit or typical Specifications Electric strength test voltage Input to output / No isolation 7- Reliability Data Characteristics Conditions Temperature Specifications Mean Time Between Failure (MTBF) According to MIL-HDBK-217F Ground fixed (Gf) Airborne, Inhabited, Cargo (AIC) Case at 0 C Case at 85 C Case at 0 C Case at 85 C 1 500 000 Hrs 590 000 Hrs 730 000 Hrs 300 000 Hrs Mean Time Between Failure (MTBF) According to IEC-62380-TR Civilian avionics, calculators Ambient at 55 C 100% time on Consult factory Gaia Converter FC97-027.0/12 Revision L

8- Thermal Characteristics Characteristics Conditions Limit or typical Performances Operating ambient temperature range at full load Operating case temperature range at full load Storage temperature range Thermal resistance Ambient temperature * Case temperature Non functionning Rth case to ambient in free air natural convection Note * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 105 C. - 0 C + 90 C - 0 C +105 C - 55 C + 125 C Typical 12 C /W The HUGD-50 series operating case temperature must not exceed 105 C. The maximum ambient temperature admissible for the DC/DC converter corresponding to the maximum operating case temperature of 105 C depends on the ambient airflow, the mounting/orientation, the cooling features and the power dissipated. To calculate a maximum admissible ambient temperature the following method can be used. Knowing the maximum case temparature Tcase = 105 C of the module, the power used Pout and the efficiency η : determine the power dissipated by the module Pdiss that should be evacuated : Pdiss = Pout(1/η - 1) determine the maximum ambient temperature : Ta = 105 C - Rth x Pdiss where Rth is the thermal resistance from the case to ambient. The previous thermal calculation shows two areas of operation : a normal operation area in a free natural ambient convection (grey area in this following graph), an area with cooling features (air flow or heatsink) ensuring a maximum case temperature below the maximum operating case temperature of 105 C (white area in the following graph). Power (W) 100% 75% Additionnal cooling operation area 50% 25% Natural convection operation area 10 20 30 0 50 60 70 80 90 100 110 Temperature ( C) Full load ambient temperature without derating : 90 C case temperature : 105 C storage temperature : 125 C Gaia Converter FC97-027.0/12 Revision L 5

9- Environmental Qualifications The modules have been subjected to the following environmental qualifications. Characteristics Conditions Severity Test procedure Climatic Qualifications Life at high temperature Altitude Humidity cyclic Humidity steady Salt atmosphere Temperature cycling Temperature shock Temperature / status of unit Altitude level C Climb up Stabilization Number of cycle Cycle duration Relative humidity variation Temperature variation Damp heat Temperature Temperature Concentration NaCl Number of cycles Temperature change Transfert time Steady state time Number of shocks Temperature change Transfert time Steady state time Test D : 1 000 Hrs @ 105 C case, unit operating @ 125 C ambient, 0 000 ft@-55 C 30 min. 1 000 ft/min to 70 000 ft@-55 C, 30 min. unit operating 10 Cycle I : 2 Hrs 60 % to 88 % 31 C to 1 C 93 % relative humidity 0 C 56 days 35 C 5 % 8 Hrs 200-0 C / +85 C 0 min. 20 min. unit operating 100-55 C / +105 C 10 sec. 20 min. MIL-STD-202G Method 108A MIL-STD-810E Method 500.3 MIL-STD-810E Method 507.3 MIL-STD-202G Method 103B MIL-STD-810E Method 509.3 MIL-STD-202A Method 102A MIL-STD-202G Method 107G Mechanical Qualifications Vibration (Sinusoidal) Shock (Half sinus) Bump (Half sinus) Number of cycles Frequency / amplitude Frequency / acceleration Number of shocks Peak acceleration Shock form Number of bumps Peak acceleration 10 cycles in each axis 10 to 60 Hz / 0.7 mm 60 to 2 000 Hz / 10 g 2h 30 min. per axis 3 shocks in each axis 100 g 6 ms 1/2 sinusoidal 2 000 Bumps in each axis 0 g 6 ms MIL-STD-810D Method 51.3 MIL-STD-810D Method 516.3 MIL-STD-810D Method 516.3 Gaia Converter FC97-027.0/12 Revision L 6

10- Application Notes 10-1 General on Input Bus Shut- Down Requirements During bus power drop-out, avionics and military systems require a maintain of operation for data saving and shut-down control. The duration of this shut-down operation is defined in different standards and can last up to 7 secondes. 10-1-1 Capacitor Stand-Alone Solution To maintain operation during power drop-out, the traditional approach is to use a bulk capacitor connected at the input of the converters to power them when power drops-out. This capacitor depends on the system specifications, the load, the efficiency of the DC/DC converter and the hold-up time requirement. The value of the capacitance is determined by the following formula : 10-1-2 Capacitor with Hold Up Module Solution To reduce drastically the size of this capacitor, GAIA Converter proposes the HUGD-50 hold up module that will charge the capacitor at a higher voltage, typically 38V. Moroever this module also allows to select the minimum threshold voltage at which the capacitance will power the converters. In this case the amount of capacitance needed for a given hold up time is determined by the following formula : C1 = 2 x P x Dt ( V1 2 - V2 2 ) C2 = 2 x P x Dt ( 38 2 - V2 2 ) where : C : is the required capacitor (in farads) P : is the consumed power (at HUGD output) Dt : is the required hold up time (in seconds) V1 : is the initial charged capacitor voltage (in volts) V2 : is the low line voltage of DC/DC converter where : C : is the required capacitor (in farads) P : is the consumed power (at output of HUGD) (in watts) Dt : is the required hold up time (in seconds) V2 : is the low line voltage of DC/DC converter (in volts). For a typical 50ms hold-up time requirement on 50W output DC/DC converter with 80% efficiency - i.e 62,5W consumed power - with a minimum permanent input voltage of 16V connected on a standard MIL-STD-70 28V bus that can range down to 22V, the resulting capacitor is a large 27 00uF/0V. For a typical 50ms hold-up time requirement on 50W output DC/DC converter with 80% efficiency - i.e 62,5W consumed power - with a minimum permanent input voltage of 16V connected on a MIL-STD-70 28V bus, using the HUGD-50 will reduce the capacitor value down to 6 300uF/0V. Gaia Converter FC97-027.0/12 Revision L 7

10- Application Notes (continued) 10-2 Hold-up Capacitor Selection with HUGD-50 Solution The external capacitor supplies the energy for the DC/DC converters operation during power drop-out. The capacitance should not exceed 30.000µF, and should be higher than 70µF. The amount of capacitance for a given hold up time is given by the formula : 2 x P (Dt + 0.01 ) C = 38 2 2 -V L where C P Dt V L : is the required capacitance (in Farads) : is the consumed power (at the output of HUGD) (in Watts) : is the required hold-up time (in seconds). 10ms are added for design margin : is the lowest admissible voltage of DC/DC converters (in volts) 1000 The following curve gives the hold up time as a function of the capacitor value. Gaia Converter recommends a low ESR extended temperature range electrolytic capacitor. Hold up time as a function of hold up capacitance 900 800 700 50W 0W 30W 20W Hold-up time (ms) 600 500 00 300 200 100 0 0 5 000 10 000 15 000 20 000 25 000 30 000 Hold-up capacitance ( F) Gaia Converter FC97-027.0/12 Revision L 8

10- Application Notes (continued) 10-3 Power Fail Voltage Threshold : Vth The «power fail voltage» threshold determines the operation mode of the HUGD-50. This threshold has to be set up in conjunction with the type of modules used (i.e. 9-36 or 16-0 input voltage type of modules) and can be adjusted between 8,8 and 15,3 by an external resistor Rth connected between the Vth pin and ut pin. Vth unconnected will set the threshold at 15,3 valid for 16-0Vdc input modules whereas Vth connected to ground will set the threshold at 8,8 valid for 9-36Vdc input modules. If the HUGD-50 is used with the PGDS-50-N-K, Vth has to remain unconnected; with the PGDS-50-O-K, Vth has to be connected to. The following curve shows the Vth function threshold as a function of the resitor Rth. The hysteresis on the undervoltage detection is typically 1V. Once an undervoltage has been detected and the input bus has been disconnected to switch on the hold-up capacitor energy reservoir, the HUGD-50 will reconnect the input bus when it is 1V above the value set with the Vth pin. Therefore, it is recommended to minimize the series resistance of elements in front of the HUGD-50 to prevent false triggerings when the input current becomes 0A as the Vth threshold is reached and the bus is disconnected, because the voltage at the input of the HUGD-50 will then slightly increase. The resulting unwanted bounces may lead to a loss of stored energy and internal switch overstress. The series resistance should be kept below 0,75 x Vth / Pout. Power fail voltage threshold versus Rth 16 Power fail voltage threshold (Vdc) 15 1 13 12 11 10 9 8 0,1 1 10 100 1000 Rth (kohms) 10- Charging Current Setting : V CL The HUGD-50 controls the charging current to remain between 100 ma to 2A by an external resistance Rcl connected between the Vcl pin and the ut pin. This charging current is a direct function of the charging time knowing that the capacitor is charged at 38. The following curve gives the resistance Rcl value as a function of current & charging time. 2.5 Input charging current as function of external resistor Rcl 900 Input charging rate as function of external resistor Rcl Input reflected charging current (A) 2 1.5 1 0.5 Vi=16V Vi=28V Vi=0V Charging rate in µs/µf 800 700 600 500 00 300 200 Vi=16V Vi=28V Vi=0V 100 0 0 500 1000 1500 2000 2500 Rcl Gaia Converter FC97-027.0/12 Revision L 0 0 500 1000 1500 2000 2500 Rcl 9

10- Application Notes (continued) 10-5 Power Fail Signal : PF The «power fail» output signal is activated when the voltage drops below the power fail voltage threshold. The PF signal is an active low open-drain output. 10-6 Capacitor Discharged Signal : CD The «Capacitor discharged» signal is activated when the voltage at the hold-up capacitor pin reaches the value programmed with the Vth pin + 0.9V to inform the system that the energy storage capacitor voltage is closed to the value which is considered a «power fail» event. It can be used as a last warning before system shut-off. With the Vth pin unconnected, the corresponding value will be Vc = 16.2V, whereas with the Vth pin grounded, the corresponding value will be Vc = 9.7V. The CD signal is an open drain active low output. 10-7 Capacitor Charged Signal : CC The «capacitor charged» signal is actived when the voltage at the capacitor pins reaches 35 corresponding to an energy stored of about 90% of it s full charge. The CC signal is an active low open-drain output. 10-8 Transition Capacitor To help transitionning the system in the different operating mode, GAÏA Converter recommends the use of a transition capacitor. This capacitor is used to maintain output voltage during the HUGD-50 switching from input line to hold up capacitor. A 100µF electrolytic capacitor is enough for a 50W load, and this value can be reduced for lower loads. The table below gives the minimum required values versus output power : Output power (W) Capacitance value (µf) 10 20 30 0 50 22 7 68 82 100 10-9 Typical Schematics This typical application schematics includes an EMI filter, a PGDS-50 pre-regulator, the hold-up module and an assembly of standard DC/DC converters. Additionnal details are given in the EMI filters application notes and PGDS-50 datasheet. Power fail signal Capacitor charged signal Capacitor discharged signal R* +Vo + Input Vo C* 1 2 Vimes +Vo 6 1 PF CC CD +Vo 6 MGDM-series GI EMI input Filter PGDS50 Vc 7 HUGD50 +Vo - Input GI GI On/Off 3 5 GI Vth 2 5 Vcl 3 MGDM-series GI Rth Rcl +Vo On/Off MGDM-series GI Note * : Due to possible oscillations caused by surges or fast transients at the input voltage level, it is recommended to implement a RC filter on the MES signal; several implementations as shown in the above figure can be tested to optimize the design. Typical values for the resistor R is 70 Ohm and for for the capacitance C is 1µF. Gaia Converter FC97-027.0/12 Revision L 10

10- Application Notes (continued) 10-10 Timming Diagram The following diagram describes the HUGD-50 output signals through the different operation modes : Input voltage (Vi) Output voltage to DC/DC converter (Vo) Power Fail signal (PF) Capacitor voltage (Vc) Capacitor charged signal (CC) Capacitor discharge signals (CD) Vstart Vth VO Vstart Vth PF VC 38V 35V 30,5V Vth+,9V Vth+0,9V CC CD Gaia Converter FC97-027.0/12 Revision L 11

11- Dimensions Dimension are given in mm (inches). Tolerance : +/- 0,2 mm (+/- 0.01 ) unless otherwise indicated. Weight : 20 grams (0.7 Ozs) max. 0 (1.58") 26 (1.03") 7,60 (0.30") 8 (0.32") 5 min (0.20") 26,20 (1.03") 5,08 (0.20") 7,62 (0.30") 35,56 (1.0") Pin dimensions : O 0,73 mm (0.03 ) 20,32 (0.80") 10,16 (0.0") 2,5 (0.10") 2,5 (0.10") 7,62 (0.30") 3 x 2,5 (3 x 0.10") 12- Materials Case : Metallic black anodized coating. Pins : Plated with pure matte tin over nickel underplate. 13- Product Marking Upper face : Company logo, location of manufacturing. Side face : Module reference : HUGD-50. Date code : year and week of manufacturing, suffix, /option. 1- Connections 6 7 8 9 10 1 2 3 Bottom view 5 Pin HUGD-50 1 + Input (Vi) 2 Power Fail Threshold (Vth) 3 Voltage Current Level (Vcl) - Input (Gi) 5 Common () 6 Output (Vo) 7 Voltage Capacitor (Vc) 8 Power Fail Signal (PF) 9 Capacitor charged signal (CC) 10 Capacitor discharged signal (CD) Gaia Converter FC97-027.0/12 Revision L 12

For more detailed specifications and applications information, contact : International Headquarters GAÏA Converter - France ZI de la Morandière 33185 LE HAILLAN - FRANCE Tel. : + (33)-5-57-92-12-80 Fax : + (33)-5-57-92-12-89 Represented by : North American Headquarters GAÏA Converter Canada, Inc 038 Le Corbusier Blvd LAVAL, QUEBEC - CANADA H7L 5R2 Tel. : (51)-333-3169 Fax : (51)-333-519 Information given in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed for the consequence of its use nor for any infringement of patents or other rights of third parties which may result from its use. These products are sold only according to GAIA Converter general conditions of sale, unless otherwise confirmed by writing. Specifications subject to change without notice. Printed in France by GAIA Converter Gaia Converter FC97-027.0/12 Revision L. Graphisme : Philippe Clicq