Installation and Setup Instructions

Similar documents
EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

Issue 2.0 December EPAS Midi User Manual EPAS35

CORONA E ELECTRONIC METER MULTI-JET

HYDRUS ULTRASONIC METER

THE SOFTWARE WILL BE AVAILABLE ON TechCONNECT ON FEBRUARY 3, 2004.

PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

HYDRUS ULTRASONIC METER

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

Touch plate serial number. Please save this info here for use later:

EPAS Desktop Pro Software User Manual

Ultrasonic heat meter

TPMS Adapter Instruction Manual. (Tire Pressure Monitoring System)

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

zelsius Installation and operating manual All that counts. EnergyMetering

SP PRO KACO Managed AC Coupling

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

ZT-USB Series User Manual

Heat Meter Integrator

DISPLAYS: MFA 10. Components of the MFA 10

OVERVIEW: This bulletin involves selectively erasing and reprogramming the Powertrain Control Module (PCM) with new software.

INSTALLATION USER MANUAL

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

CIRRUS AIRPLANE MAINTENANCE MANUAL

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

WESAN WPV E ELECTRONIC METER WOLTMAN

Maintenance and Service Instructions

Water Specialist EE Control Valve Programming and Cover Drawing Manual

CurveMaker DFS v2.0 Dyna FS Ignition Programming Software

Harris IRT Enterprises Digital Resistance Tester Model XP


Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

CORONA ER ELECTRONIC METER MULTI-JET

or, with the time and date option enabled using the CommFlags command:

E / EHCD Control modules for hydraulic transmissions.

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100...

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

INSTALLATION INFORMATION

Phaeton Convenience and Safety Electronics

THE DRBIII FLASH FILES FOR THIS BULLETIN ARE AVAILABLE ON DealerCONNECT.

FL-100-R (109) Operations and Installation Manual

The Minerva driver connects to a single Minerva MX fire panel. Available for Commander and ObSys.

THE witech SOFTWARE LEVEL MUST BE AT RELEASE OR HIGHER TO PERFORM THIS PROCEDURE.

Water Specialist PR Control Valve Programming and Cover Drawing Manual

E61, E63, E64 BMW AG - TIS

BRAKE TESTER DECELEROMETER

Water Specialist EI Control Valve Programming and Cover Drawing Manual

X11CA-IM MASTER MODULE

Vehicle CAN Database. Porsche 911 (991) GT3 Cup Gen1 - Bosch Connector

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Advanced User Manual

Table of Contents. General Information...1. Components...2. Connection...4

THIS BULLETIN IS BEING PROVIDED IN ADVANCE. THE SOFTWARE WILL BE AVAILABLE ON TechCONNECT ON OR AFTER DECEMBER 15, 2003.

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

zelsius Installation and operating manual All that counts EnergyMetering

bf1systems DigiTyre II TPMS User Guide

PCT200 Powercast High-Function RFID Sensor Datalogger

IDL Dragonfly Manual

DIGITAL TORQUE GAUGE MODEL BTGE-G

SPG-DIGI. Operating Instruction. Please read carefully before use!

ALLIGATOR sens.it sensor intelligent technology. The universal TPMS solution for professionals

ZEPHYR FAQ. Table of Contents

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

MiX 2310i with IP Housing. P r o d u c t I n f o r m a t i o n G u i d e

E61, E63, E64, E70, E81, E87, E90, E91, E92, E93 BMW AG - TIS

GB... Guldmann Service and Information Console SW v User manual - vers. 7

Abrites Diagnostics for Peugeot/ Citroën User Manual abrites.com

Marine Exhaust Temperature Alarm. COMPONENTS

Holden VZ 3.6L ECU & Powertrain Interface Module Linking Instructions

KEMKRAFT ENGINEERING, INC. MODEL KEI-434 STEERING WHEEL TORQUE TESTER

Tension Meter. PT Series. Instruction Manual PT-100-L. Valid as of: Please keep the manual for future reference!

Superstatic 440. Static Heat- and Cooling Meter. Application

Automated Seat Belt Switch Defect Detector

RAY COMPACT ENERGY METER MECHANICAL

X117E. X117E Contact-Less Valve Position Transmitter INSTALLATION / OPERATION / MAINTENANCE MODEL. X117E Contact-Less Valve Position Transmitter

M-bus impeller type heat and heat/refrigeration meters

SmartON / SmartON+ Installation and Use Manual

12 VOLT BATTERY & ELECTRICAL SYSTEM ANALYSER

TECHNICAL MANUAL FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

CAN-Translator. User s guide

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

7 Services Control and monitoring

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Technical Information

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

I. CONNECTING TO THE GCU

IFC-BL02 Interface Free Controller Brushless Motor Card

PLS 210 Single-Channel High-speed Programmable Limit Switch Module User s Guide

ET9500 BEMS Interface Box Configuration Guide

Operating Instructions Indicating and adjustment module for IPT-1* sensors

Instruction Manual. SmarTire Dealer Programming Tool. PN: Revision Copyright 2006 SmarTire Systems Inc.

LOV-T FRYER COMMISSION AND DEMONSTRATION FORM 8700 LINE AVENUE SHREVEPORT, LA (800) Date

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

User Manual. Rev USER MANUAL MForks 1

Transcription:

EWA1xxC-MBUS Installation and Setup Instructions These instructions are valid for the following modules: OS-Number EWA110C1520-MBUS EWA110C2540-MBUS EWA160C-MBUS EWA171C-MBUS Table 1. OS-Numbers covered Item M-Bus clipon module for EW110 Series, DN15 and DN20 M-Bus clipon module for EW110 Series, DN25 to DN40 M-Bus clipon module for EW160 Series, DN15 to DN32 M-Bus clipon module for EW171 Series, DN50 to DN300 1 Preparation Programming of M-Bus clip on modules is done via the M-Bus master. It is not possible to program the module before it has been connected to the M-Bus. For programming the secondary address of the module must be known. If the actual volume should be included in the programming this data must also be known. Figure 1. EW110 with installed module 1.1 Standard Values Before programming modules check if standard values are not sufficient and thus make programming needless: OS-No. Baud rate Volume Table 2. Standard values Backward flow Min/max flow Leakage Primary address Lack of flow EWA110C1520-MBUS 2,400 0 deactivated deactivated, JS1.6 deactivated 0 deactivated EWA110C2540-MBUS 2,400 0 deactivated deactivated, JS6.3 deactivated 0 deactivated EWA171C-MBUS 2,400 0 deactivated deactivated, MWN40 deactivated 0 deactivated EN2H-0465GE25A R0815 Page 1 of 7

1.2 Required Parts The following parts are required to change the programming of the module. The list is based on the assumption that programming will be done via an EW535M IzarCenter M-Bus master unit. Part Serial cable (supplied with Izar- Center) Function Interface between PC and module Table 3. Required parts USB / serial adapter Connect serial cable to PCs without serial interface Configuration software EWASET-MBUS Program new values into module Downloadable free of charge from http://metering.ecc.emea.honeywell.com 1.3 Wiring to PC Wiring between PC and module is done via the M-Bus master. Connection between PC and M-Bus master must be done over the serial port, not the USB port, of the IzarCenter. Figure 2. Connection to PC EN2H-0465GE25A R0815 Page 2 of 7

2 Programming 2.1 Wake up NOTE: This chapter applies only to modules produced before August 2015. After production the module is put into sleep mode to save battery life. When installed on a meter the module is woken up automatically. For programming before installation briefly place a magnet near the reed switch of the module. By this the module is woken up from sleep mode. Figure 3. Position of reed switch in module EWA110C1520-MBUS and EWA110C2540-MBUS Figure 4. Position of reed switch in module EWA171C-MBUS Figure 5. Briefly place magnet near reed switch 2.2 Software Figure 6. Screenshot of parametrisation program EN2H-0465GE25A R0815 Page 3 of 7

2.2.1 Fields Table 4. Overview of fields Field No. Field name Field type Function 1 Port COM Pulldown Select COM port over which the PC is connected to the M-Bus master. 2 Module No. Input Put in secondary address of module which should be programmed. 3 Baud rate Pulldown Select baud rate for communication. Standard baud rate is 2,400. 4 Set new baud rate Pulldown Select new baud rate if required and program with Set baud button. 5 Set baud Execute button 6 Refresh COMs Execute button 7 Events reset Execute button 8 Volume Activation / input Optionally put in meter volume count 9 Module type Pulldown Select module type to be addressed 10 Set present time Activation Optionally activate if PC time should be programmed into module. 11 Backward flow Activation / input Optionally set backward flow threshold. 12 Min/Max flow Activation / pulldown Optionally set minimum and maximum flow rates by selecting type of meter attached. 13 Leakage duration Activation / input Optionally set a threshold after which a leakage alarm is generated. 14 Primary address Activation / input Optionally set new primary address. 15 Lack of flow Activation / 2 inputs Optionally set a threshold for time and volume after which an alarm is generated in case no flow took place. 16 Set data button Execute button Program values into module. 2.2.2 Field Description 2.2.2.1 Port COM Required to select the correct COM port over which the PC is connected to the M-Bus master unit. 2.2.2.2 Module No. The module number is the unique identification number of the module to be addressed. (It is also the secondary address of the module.) In this field the module number of the module to which the parametrisation data shall be sent is put in. The module number is printed on the label on the top of the module, see Figure 7. Figure 7. Label of M-Bus module EWA110C1520-MBUS EN2H-0465GE25A R0815 Page 4 of 7

2.2.2.3 Baud rate In this field the actual baud rate of the module is entered. Standard value is 2,400. 2.2.2.4 Set new baud rate In this field a new baud rate can be entered if the standard baud rate should be changed. Baud rate can be set to 300 or 2,400 baud. 2.2.2.5 Set baud Upon execution baud rate of module will be set to value selected in field 4. Successful baud rate change is confirmed by a system message. 2.2.2.6 Refresh COMs Upon execution the list of COM ports currently recognised by the program will be updated. 2.2.2.7 Events reset Upon execution the error log of the module is erased. Fields 8 and 10 16 are optional configuration items. They can be individually activated by setting a tick in the box before the input field and entering a value. 2.2.2.8 Volume In this field the actual meter count should be entered to ensure that the meter reading and the value reported over the M-Bus are identical. When the M-Bus module is installed onto the water meter the reading of the meter is never 0.000: in case of a retrofit the meter is likely to have been in operation already. But also in case of a new meter the reading is not zero due to qualification testing which is undertaken on every meter before it is released for shipment. The information in this field ensures that the reading over the M-Bus is identical with the count shown on the meter face. In below example (Figure 8) the reading is 290.35 litres. The input value is 290 as the field is populated with full litres, no decimal places. Figure 8. Front face of EW1100AC1200 EN2H-0465GE25A R0815 Page 5 of 7

2.2.2.9 Module type In this field the correct module must be selected: Select: AT-MBUS-01 AT-MBUS-02 AT-MBUS-03 AT-MBUS-04 DN<150 AT-MBUS-04 DN>=150 For M-Bus module: EWA110C1520-MBUS EWA110C2540-MBUS EWA160C-MBUS EWA171C-MBUS on meter size DN50 up to DN125 EWA171C-MBUS on meter size DN150 or larger Figure 9. Pulldown of field Module type 2.2.2.10 Set present time When this field is actived the computer time and date will be transmitted to the module and overwrite the value stored in the module. 2.2.2.11 Backward flow When this field is activated a threshold for backward flow can be input in litres and an error message will be generated whenever this threshold is exceeded. 2.2.2.12 Min/Max flow When this field is activated the type of meter can be selected in terms of flow. In this case an error message is generated whenever the flow values are outside of the approved meter range. The following values are available. OS-Number EW110 0600 means all OS-Numbers starting with EW110 and ending with 0600 are included. Table 5. Min/Max flow values Field value For OS-Numbers Min flow value Max flow value JS 1,6 EW110 0600 10 litres / hour 2 m³ / hour JS 2,5 EW110 1100 EW110 1200 EW110 1400 16 litres / hour 3.125 m³ / hour JS 4 EW110 2000 25 litres / hour 5m³ / hour JS 6,3 EW110 2800 32 litres / hour 7.9 m³ / hour JS10 EW110 3900 50 litres / hour 12.5 m³ / hour JS16 EW110 4600 80 litres / hour 20 m³ / hour SV-RTK-2,5 SV-RTK-4 EW1600..1200 EW1600..1202 EW1600..1500 EW1600..2110 EW1600..2200 6.3 litres / hour 3 m³ / hour 10 litres / hour 5 m³ / hour EN2H-0465GE25A R0815 Page 6 of 7

Field value For OS-Numbers Min flow value Max flow value SV-RTK-6,3 EW1600..2800 16 litres / hour 8 m³ / hour SV-RTK-10 EW1600..3900 25 litres / hour 12.5 m³ / hour MWN50 EW171 5000 0.4 m³ / hour 50 m³ / hour MWN65 EW171 5600 0.5 m³ / hour 79 m³ / hour MWN80 EW171 6500 0.63 m³ / hour 125 m³ / hour MWN100 EW171 7300 0.8 m³ / hour 200 m³ / hour MWN125 EW171 8100 1.6 m³ / hour 313 m³ / hour MWN150 EW171 8500 2 m³ / hour 500 m³ / hour MWN200 EW171 8900 5 m³ / hour 788 m³ / hour MWN250 EW171 9100 10 m³ / hour 1,250 m³ / hour MWN300 EW171 9200 16 m³ / hour 2,000 m³ / hour NOTE: For EW110 Series min flow of version with dynamic range of R160 is used. For EW160 Series min flow of version with dynamic range of R400 is used. For EW171 Series min and max flows of cold water meter are used. 2.2.2.13 Leakage duration When this field is activated a threshold for leakage can be input in minutes where the threshold value is ten times the input value. Example: when 6 is input the threshold value will be 60 minutes (6 x 10). An error message will be generated whenever this threshold is reached or exceeded, i.e. when there has been a continuous flow for sixty minutes or more. 2.2.2.14 Primary address When this field is activated a new primary address can be set between 1 and 250. The module is supplied with primary address 0. 2.2.2.15 Lack of flow When this field is activated a threshold for no flow can be input and an error message will be generated whenever this threshold is not reached in the given number of days. The threshold is defined in terms of days and total volume. It means that whenever the defined volume is not reached within the number of days defined an error message is generated. 2.2.2.16 Set data Upon execution parametrisation data will be written into the module. Successful transmission is confirmed by a system message. EN2H-0465GE25A R0815 Page 7 of 7