Fan-Powered Low-Height Series

Similar documents
Fan-Powered Parallel

Fan-Powered Low-Height Series

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6

Fan-Powered Series. Table of Contents. Model Number Description FPS 2 3. Service Model Number Description FPS 4. Selection Procedure FPS 5 7

Fan-Powered Parallel

FAN POWERED TERMINAL UNITS

SINGLE DUCT TERMINAL UNITS

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Installation, Operation, and Maintenance

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals

FAN POWERED TERMINAL UNITS

SECTION AIR TERMINAL UNITS

catalog SDL Single-Duct, Low-Height, VAV Terminals

HOW TO SPECIFY SDV UNITS

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

Variable Air Volume Dampers

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.

University of Delaware

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

TSS Single-Duct VAV Terminals

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

IAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW

SINGLE DUCT AIR TERMINAL UNITS

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

SINGLE DUCT TERMINAL UNITS 3000 SERIES

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

FDCLP2 Constant Volume Series Flow, Low Profile

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Laboratory Room Single Duct Supply Air Terminal

Variable Air Volume (VAV) Pressure Independent Control

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems

I Fan Powered Terminal Unit

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

FCVC Series VERTICAL FAN COILS

Dual Duct Variable Air Volume Terminal (Model TDS)

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

IAQ. ROUND DUCT RETROFIT Model ARR

High Performance Fan Coils FCHG Genesis Series Horizontal

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

AIR FLOW SOLUTIONS. MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit. MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit

Submittal. Front View Side View

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

Product Catalog. VariTrane Products Single Duct/Dual Duct Units VDD, VCC, VCW, VCE VAV-PRC011M-EN. Variable-Air-Volume (VAV) System.

VariTrane VAV Terminal Unit. Single-Duct Series Fan-Powered Parallel Fan-Powered

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Fan - Powered Terminal Unit Series Flow

catalog SDR Single-Duct VAV Terminals

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Laboratory Room Single Duct Supply Air Terminal

FS Fan-Coil Units Hi-Rise, Vertical

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

FN Fan-Coil Units High-Performance, Horizontal

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

VERTICAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

MODULAR SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e

AIR 3 1/4" [ 83 ] ELECTRICAL CONTROL BOX FOAM LINED CONNECTION SLOPED DRAIN PAN EXTERNALLY INSULATED WITH FOAM SHIPPED LOOSE FOR FIELD INSTALLATION

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

Technical information

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

FW and FL Fan-Coil Units Floor-Mounted, Vertical STANDARD AND LOW PROFILE

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

IOM 002 Effective 12/17 A I R D I S T R I B U T I O N M O D E L Q S T M O D E L Q P T M O D E L E S T

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Controls Analog. Options. Single-Duct Terminal Unit (VCCF, VCWF, and VCEF)

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

HORIZONTAL SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING WITH HOT WATER OR ELECTRIC HEAT

LMHS BASIC UNIT NO CONTROLS

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

SINGLE DUCT AIR TERMINAL UNITS

Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series

T VB FA N COIL U NIT S F LO OR -MOU NT E D, V E RT ICA L

FPV, FDV Series Variable Volume Parallel Flow

Electric Furnace KF/KFS Series

ATU PRODUCT CATALOG AIR TERMINAL UNITS OPTIONS AND ACCESSORIES Metal Industries, Inc.

SPV / SDV Series SINGLE DUCT TERMINAL UNITS

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

Fan Powered Low Profile Variable Volume Terminal Units

engineering guide TCS Series Fan-Powered, VAV Terminals

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

Transcription:

Table of Contents Service Model Number Description LHS 2 3 General Data Valve/Controller Guidelines LHS 4 Performance Data Pressure Requirements LHS 5 7 Performance Data Fan Curves LHS 8 9 Performance Data Hot ater Coil LHS 10 11 Performance Data Electrical Data LHS 12 13 Performance Data coustics LHS 14 17 Dimensional Data LHS 18 25 Mechanical Specifications LHS 26 28 VV-PRC008-EN LHS 1

Service Model Number Description Fan- Powered Terminal Units The features of the low-height series fan-powered terminal units are described by the product categories shown below in bold. ithin each category the options available are listed. LSCF LSF LSEF Digit 1, 2 Unit Type LS VariTrane low-height series fan-powered Digit 3 Reheat C Cooling Only E Electric Heat Hot ater Heat Digit 4 Development Sequence F Sixth Digit 5, 6 Primary ir Valve 06 6" inlet (500 cfm) 08 8" inlet (900 cfm) RT (8" x 14" inlet (1800 cfm) Digit 7, 8 Secondary ir Valve 00 N/ Digit 9 Fan H 08 Fan 850 maximum cfm J 09 Fan 1200 maximum cfm K 10 Fan 1900 maximum cfm Digit 10, 11 Design Sequence E0 Fifth (factory assigned) Digit 12, 13, 14, 15 Controls ENON No controls, field-installed DDC/electric PNON No controls, field-installed pneumatic DD00 Trane elec actuator only DD01 DDC cooling only DD02 DDC N.C. on/off water valve DD03 DDC prop hot water valve DD04 DDC on/off electric heat control DD05 DDC pulse-width modulation DD07 DDC N.O. on/off water valve FM00 FM customer actuator & control FM01 FM Trane actuator w/ customer VM2 actuator & control FM Johnson controls VM-1420 PR1 FM Seimens 540-100 w/ GDE131.1P actuator PR4 FM Seimens 540-100 Trane actuator PR5 FM Seimens 540-100 w/ GDE131.1U actuator T01 T02 EI71 PN00 PN51 PN52 FM utomated Logic U341V+ FM utomated Logic U141V+ nalog fan-powered on/off reheat PN N.O. Trane pneumatic actuator, R.. stat PN N.O. PVR, duct pressure switch, R.. stat PN N.O. PVR, dual pressure switch, R.. stat Notes: N.C. = Normally-closed N.O. = Normally-opened D Stat = Direct-acting pneumatic t-stat (by others) R Stat = Reverse-acting pneumatic t-stat (by others) PN = Pneumatic FM = Factory installation of customersupplied controller Digit 16 Insulation 1/2" Matte-faced 1" Matte-faced C 1/2" Foil-faced D 1" Foil-faced F 1" Double-wall G 3/8" Closed-cell Digit 17 Motor Type D PSC Motor Digit 18 Motor Voltage 1 115/60/1 2 277/60/1 3 347/60/1 5 230/50/1 Digit 19 Outlet Connection 1 Flanged 2 Slip & Drive Digit 20 Not Used 0 N/ Digit 21 ater Coil 0 None 1 1-Row Plenum inlet installed 2 2-Row Plenum inlet installed 3 1-Row Discharge installed, Left-hand 4 1-Row Discharge installed, Right-hand 5 2-Row DIscharge installed, Left-hand 6 2-Row Discharge installed, Right-hand Digit 22 Electrical Connections L Left (airflow hitting you in the face) Digit 23 Transformer 0 N/ (provided as standard) Digit 24 Power Disconnect 0 None ith Digit 25 Power Fuse 0 None ith LHS 2 VV-PRC008-EN

Service Model Number Description Digit 26 Electric Heat Voltage 0 None 208/60/1 208/60/3 C 240/60/1 D 277/60/1 E 480/60/1 F 480/60/3 G 347/60/1 H 575/60/3 J 380/50/3 Digit 27, 28, 29 Electric Heat Voltage 000 None 005 0.5 k 010 1.0 k 015 1.5 k 020 2.0 k 025 2.5 k 030 3.0 k 035 3.5 k 040 4.0 k 045 4.5 k 050 5.0 k 055 5.5 k 060 6.0 k 065 6.5 k 070 7.0 k 075 7.5 k 080 8.0 k 090 9.0 k 100 10.0 k 110 11.0 k 120 12.0 k 130 13.0 k 140 14.0 k 150 15.0 k 160 16.0 k 170 17.0 k 180 18.0 k Digit 30 Electric Heat Stages 0 None 1 1 Stage 2 2 Stages Equal Digit 31 Contactors 0 None 1 24-Volt magnetic 2 24-Volt mercury 3 PE with magnetic 4 PE with mercury Digit 32 ir Flow Switch 0 None ith VV-PRC008-EN LHS 3

General Data Valve/Controller Guidelines Primary Control Factory Settings I-P Control ir Valve Maximum Valve Maximum Controller Minimum Controller Constant Volume Type Size (in.) Cfm Cfm Cfm Cfm 5 350 40 350 0, 40 350 40 350 Direct Digital Control/ 6 500 60 500 0, 60 500 60 500 UCM 8 900 105 900 0, 105 900 105 900 8x14 2200 200 2200 0, 220 2200 220 2200 5 350 63 350 0, 63 350 63 350 Pneumatic with 6 500 73 500 0, 73 500 73 500 Volume Regulator 8 900 134 900 0, 134 900 134 900 8x14 2100 297 2100 0, 297 2100 297 2100 5 350 82 350 0, 82 350 82 350 nalog Electronic 6 500 120 500 0, 120 500 120 500 8 900 210 900 0, 210 900 210 900 8x14 2200 440 2200 0, 440 2200 440 2200 Primary Control Factory Settings SI Control ir Valve Maximum Valve Maximum Controller Minimum Controller Type Size (in.) L/s L/s L/s 5 165 19 165 0, 19 165 19 165 Direct Digital Control/ 6 236 28 236 0, 28 236 28 236 UCM 8 425 50 425 0, 50 425 50 425 8x14 1038 104 1038 0, 104 1038 104 1038 5 165 30 165 0, 30 165 30 165 Pneumatic with 6 236 35 236 0, 35 236 35 236 Volume Regulator 8 425 63 425 0, 63 425 63 425 8x14 991 140 991 0, 140 991 140 991 5 165 39 165 0, 39 165 39 165 nalog Electronic 6 236 57 236 0, 57 236 57 236 8 425 100 425 0, 100 425 100 425 8x14 1038 208 1038 0, 208 1038 208 1038 Note: Maximum airflow must be greater than or equal to minimum airflow. LHS 4 VV-PRC008-EN

ir Pressure Drop in. wg (I-P) Inlet/Fan Cooling Only Size Cfm (in. wg) 06 08 415 0.26 450 0.32 475 0.35 500 0.40 08 08 425 0.06 550 0.10 675 0.16 850 0.26 08 09 560 0.10 700 0.18 800 0.24 900 0.32 8x14 09 560 0.14 800 0.29 1000 0.45 1200 0.65 8x14 10 925 0.38 1250 0.71 1600 1.17 1930 1.72 Fan 1-Row H Coil Size Cfm (in. wg) 08 450 0.06 500 0.08 600 0.11 700 0.14 750 0.16 790 0.17 09 10 600 0.03 700 0.03 800 0.04 900 0.05 1000 0.06 1100 0.07 1300 0.10 1500 0.13 1700 0.16 1800 0.18 Performance Data ir Pressure Requirements ir Pressure Drop Pa (SI) Inlet/Fan Cooling Only Size L/s (Pa) 06 08 195 65 215 81 225 89 235 98 08 08 200 14 260 25 320 39 400 63 08 09 265 26 330 44 375 60 425 80 8x14 09 265 34 375 70 475 113 565 162 8x14 10 435 95 590 177 755 292 910 428 Fan 1-Row H Coil Size L/s (Pa) 08 215 15 235 20 285 27 330 35 355 40 375 42 09 10 285 7 330 7 380 10 425 12 470 15 520 17 615 25 710 32 800 40 850 45 Fan 2-Row H Coil Size CFM (in. wg) 08 450 0.12 500 0.15 600 0.20 700 0.26 750 0.29 790 09 10 600 0.05 700 0.07 800 0.08 900 0.10 1000 0.12 1100 0.14 1300 0.19 1500 0.23 1700 0.29 1800 Notes: 1. Units with Electric Coils Only per fan size add 0.01" (3Pa) to cooling only values. 2. H Coil Only pressure drops are just the heating coil. Fan 2-Row H Coil Size L/s (Pa) 08 215 30 235 37 285 50 330 65 355 72 375 09 10 285 12 330 17 380 20 425 25 470 30 520 35 615 47 710 57 800 72 850 VV-PRC008-EN LHS 5

Unit ir Pressure Drop in. wg (I-P) Inlet/Fan Cooling Size Cfm Only 05 08SQ 150 0.01 250 0.03 350 0.11 06 08SQ 150 0.02 275 0.14 400 0.35 500 0.58 08 08SQ 150 0.01 275 0.05 400 0.13 500 0.21 06 09SQ 350 0.17 400 0.26 450 0.37 500 0.50 08 09SQ 400 0.08 600 0.24 750 0.40 900 0.61 8x14 09SQ 600 0.18 700 0.27 900 0.51 1050 0.73 08 10SQ 400 0.08 600 0.38 800 0.84 8x14 10SQ 600 0.21 900 0.50 1100 0.77 1500 1.47 Fan-Powered Performance Data ir Pressure Requirements Coil ir Pressure Drop in. wg (I-P) Fan 1-Row H 2-Row H Size Cfm (in. wg) (in. wg) 08SQ 100 0.00 0.01 200 0.01 0.03 300 0.02 0.05 400 0.03 0.07 500 0.05 0.10 09SQ 400 0.03 0.07 550 0.06 0.12 700 0.09 0.17 850 0.13 0.24 1000 0.18 0.32 10SQ 400 0.01 0.02 800 0.03 0.07 1200 0.06 0.12 1600 0.11 0.20 2000 0.16 0.29 Note: H Coil Only pressure drops do not include unit pressure drop. ttenuator ir Pressure Drop (I-P) Fan Plenum Size Cfm ttenuator 08SQ 150 0.02 250 0.04 350 0.06 450 0.09 09SQ 350 0.06 500 0.10 650 0.15 800 0.22 10SQ 400 0.02 700 0.05 1000 0.09 1300 0.14 1600 0.20 LHS 6 VV-PRC008-EN

Performance Data ir Pressure Requirements Unit ir Pressure Drop Pa (SI) Fan/Inlet Cooling Size L/s Only 05 08SQ 71 2 118 9 165 28 06 08SQ 71 5 130 34 189 86 236 143 08 08SQ 71 3 130 14 189 32 236 52 06 09SQ 165 43 189 66 212 93 236 124 08 09SQ 189 21 283 59 354 100 425 151 8x14 09SQ 283 44 330 66 425 126 495 182 08 10SQ 189 20 283 94 378 209 8x14 10SQ 283 51 425 124 519 191 708 367 Coil ir Pressure Drop Pa (SI) Fan 1-Row H 2-Row H Size L/s (Pa) (Pa) 08SQ 47 1 3 94 3 6 142 5 11 189 9 18 236 13 25 09SQ 189 9 18 260 15 29 330 23 43 401 33 0 472 44 80 10SQ 189 3 6 378 8 16 566 16 31 755 27 50 944 40 72 Note: H Coil Only pressure drops do not include unit pressure drop. ttenuator ir Pressure Drop (SI) Fan Plenum Size L/s ttenuator 08SQ 71 0.01 118 0.01 165 0.02 212 0.03 09SQ 165 0.02 236 0.03 307 0.05 378 0.06 10SQ 189 0.01 330 0.02 472 0.03 614 0.04 755 0.06 VV-PRC008-EN LHS 7

Performance Data Fan Curves Pa 199 174 In. wg 0.80 0.70 08SQ PSC Notes: 1. hen attenuator is required, add inlet attenuator pressure to discharge static pressure for final fan performance. 150 0.60 Discharge Static Pressure 125 100 75 50 0.50 0.40 0.30 0.20 170 cfm min (80 L/s) 25 0.10 0 0.00 150 200 250 300 350 400 450 500 550 600 Cfm 71 94 118 142 165 189 212 236 260 283 L/s Pa 199 In. wg 0.80 09SQ PSC 174 0.70 150 0.60 Discharge Static Pressure 125 100 75 50 0.50 0.40 0.30 0.20 350 cfm min (165 L/s) LSCF and LSEF maximum Minimum 1-row coil maximum 2-row coil maximum 25 0.10 0 0.00 300 400 500 600 700 800 900 1000 1100 Cfm 142 189 236 283 330 378 425 472 519 L/s Pa 199 In. wg 0.80 10SQ PSC 174 0.70 Discharge Static Pressure 150 125 100 75 50 0.60 0.50 0.40 0.30 0.20 405 cfm min (191 L/s) 25 0.10 LHS 8 0 0.00 300 500 700 900 1100 1300 1500 1700 1900 2100 2300 Cfm 142 236 330 425 519 614 708 802 897 991 1086 L/s VV-PRC008-EN

ECM Data Fan Curves Notes: 1. ECMs (Electrically Commutated Motors) are ideal for systems seeking maximum motor efficiency. 2. hen attenuator is required, add inlet attenuator pressure to discharge static pressure for final fan performance. Discharge Static Pressure Pa In. wg LSxF 08SQ ECM 125 100 75 50 25 0.50 0.40 0.30 0.20 0.10 100 cfm min (47 L/s) 0 0.00 50 100 150 200 250 300 350 400 450 500 24 47 71 94 118 142 165 189 212 236 Cfm L/s Pa In. wg LSxF 09SQ ECM 125 0.50 100 0.40 LSCF and LSEF maximum Minimum 1-row coil maximum 2-row coil maximum Discharge Static Pressure 75 50 0.30 0.20 240 cfm min (113 L/s) 25 0.10 0 0.00 200 300 400 500 600 700 800 900 1000 94 142 189 236 283 330 378 425 472 Cfm L/s Pa In. wg LSxF 10SQ ECM 125 0.50 100 0.40 Discharge Static Pressure 75 50 25 0.30 0.20 0.10 400 cfm min (189 L/s) 0 0.00 300 500 700 900 1100 1300 1500 1700 1900 Cfm 142 236 330 425 519 614 708 802 897 L/s VV-PRC008-EN LHS 9

Performance Data Hot ater Coil (I-P) Fan Sizes 08SQ & 09SQ (I-P) ater Pressure (Cfm) Rows Gpm Drop (ft) 100 200 300 400 500 600 700 800 900 1000 1-Row 1.0 2.70 7.58 10.14 11.74 12.95 13.94 14.80 15.53 16.17 16.73 17.23 Capacity 2.0 3.03 8.40 11.80 14.11 15.95 17.52 18.90 20.14 21.26 22.28 23.25 MH 3.0 3.57 8.68 12.42 15.01 17.13 18.98 20.62 22.11 23.49 24.76 25.94 4.0 4.32 8.83 12.75 15.52 17.80 19.81 21.61 23.27 24.80 26.22 27.56 5.0 5.29 8.93 12.96 15.84 18.23 20.35 22.26 24.02 25.66 27.20 28.65 6.0 6.47 8.99 13.11 16.07 18.54 20.73 22.72 24.56 26.28 27.90 29.43 2-Row 1.0 0.81 9.49 15.53 19.58 22.46 24.66 26.40 27.78 28.90 29.83 30.62 Capacity 2.0 2.77 9.94 17.09 22.42 26.56 29.86 32.57 34.85 36.78 38.46 39.95 MH 3.0 5.73 10.09 17.65 23.49 28.17 32.00 35.22 37.97 40.34 42.43 44.27 4.0 9.62 10.17 17.94 24.06 29.03 33.16 36.67 39.70 42.34 44.68 46.76 5.0 14.40 10.22 18.11 24.40 29.56 33.89 37.59 40.81 43.63 46.13 48.38 Fan Size 10SQ (I-P) ater Pressure (Cfm) Rows Gpm Drop (ft) 450 600 750 900 1050 1200 1350 1500 1650 1800 1950 1-Row 1.0 0.20 19.27 21.19 22.66 23.83 24.84 25.66 26.40 27.05 27.63 28.15 28.63 Capacity 2.0 0.62 24.00 27.00 29.51 31.67 33.68 35.48 37.10 38.58 39.94 41.18 42.34 MH 4.0 2.35 26.92 30.85 34.23 37.24 39.98 42.51 44.86 47.06 49.13 51.08 52.97 6.0 5.15 28.07 32.38 36.15 39.54 42.67 45.58 48.31 50.89 53.34 55.67 57.89 8.0 9.00 28.68 33.22 37.20 40.82 44.16 47.29 50.25 53.06 55.73 58.29 60.75 10.0 13.90 29.07 33.74 37.87 41.63 45.12 48.40 51.50 54.46 57.29 60.00 62.61 2-Row 1.0 1.35 29.31 33.52 36.43 38.55 40.14 41.39 42.38 43.20 43.87 44.45 44.94 Capacity 2.0 4.51 35.10 41.61 46.75 50.91 54.50 57.50 60.04 62.20 64.08 65.72 67.17 MH 3.0 9.24 37.26 44.96 51.28 56.57 61.05 64.92 68.28 71.34 74.06 76.49 78.66 4.0 15.42 38.38 46.73 53.73 59.70 64.84 69.33 73.29 76.81 79.97 82.81 85.47 5.0 23.35 39.07 47.83 55.27 61.68 67.26 72.17 76.54 80.46 83.99 87.19 90.12 ater Coil Notes 1. Fouling Factor = 0.00025 2. The following equations may be used in calculating Leaving ir Temperature (LT) and ater Temperature Difference (TD). LT = ET + ( MH x 921.7 Cfm 3. Capacity based on 70 F entering air temperature and 180 F entering water temperature. Refer to correction factors for different entering conditions. ) TD = ET - LT = ( ) 2 x MH Gpm Temperature Correction Factors for ater Pressure Drop (ft) verage ater Temperature 200 190 180 170 160 150 140 130 120 110 Correction Factor 0.970 0.985 1.000 1.020 1.030 1.050 1.080 1.100 1.130 1.150 Temperature Correction Factors for Coil Capacity (MH) Entering ater Minus Entering ir 40 50 60 70 80 90 100 110 120 130 Correction Factor 0.355 0.446 0.537 0.629 0.722 0.814 0.907 1.000 1.093 1.187 LHS 10 VV-PRC008-EN

Performance Data Hot ater Coil (SI) Fan Size 08SQ & 09SQ (SI) ater Pressure (L/s) Rows L/s Drop (kpa) 47 94 142 189 236 283 330 378 425 472 1-Row 0.06 8.05 2.22 2.97 3.44 3.80 4.09 4.34 4.55 4.74 4.90 5.05 Capacity 0.13 9.04 2.46 3.46 4.14 4.67 5.14 5.54 5.90 6.23 6.53 6.81 MH 0.19 10.65 2.54 3.64 4.40 5.02 5.56 6.04 6.48 6.88 7.26 7.60 0.25 12.89 2.59 3.74 4.55 5.22 5.81 6.33 6.82 7.27 7.69 8.08 0.32 15.78 2.62 3.80 4.64 5.34 5.96 6.52 7.04 7.52 7.97 8.40 0.38 19.30 2.63 3.84 4.71 5.43 6.08 6.66 7.20 7.70 8.18 8.63 2-Row 0.06 2.42 2.78 4.55 5.74 6.58 7.23 7.74 8.14 8.47 8.74 8.97 Capacity 0.13 8.26 2.91 5.01 6.57 7.78 8.75 9.55 10.21 10.78 11.27 11.71 MH 0.19 17.09 2.96 5.17 6.88 8.26 9.38 10.32 11.13 11.82 12.44 12.98 0.25 28.70 2.98 5.26 7.05 8.51 9.72 10.75 11.64 12.41 13.10 13.71 0.32 42.96 3.00 5.31 7.15 8.66 9.93 11.02 11.96 12.79 13.52 14.18 Fan Size 10SQ (SI) ater Pressure (L/s) Rows L/s Drop (kpa) 212 283 354 425 495 566 637 708 779 849 920 1-Row 0.06 0.60 5.65 6.21 6.64 6.98 7.28 7.52 7.74 7.93 8.10 8.25 8.39 Capacity 0.13 1.85 7.03 7.91 8.65 9.28 9.87 10.40 10.87 11.31 11.71 12.07 12.41 MH 0.25 7.01 7.89 9.04 10.03 10.92 11.72 12.46 13.15 13.79 14.40 14.97 15.53 0.38 15.36 8.23 9.49 10.60 11.59 12.51 13.36 14.16 14.92 15.63 16.32 16.97 0.50 26.85 8.41 9.74 10.90 11.96 12.94 13.86 14.73 15.55 16.33 17.08 17.81 0.63 41.47 8.52 9.89 11.10 12.20 13.22 14.19 15.09 15.96 16.79 17.59 18.35 2-Row 0.06 4.03 8.59 9.82 10.68 11.30 11.77 12.13 12.42 12.66 12.86 13.03 13.17 Capacity 0.13 13.45 10.29 12.20 13.70 14.92 15.97 16.85 17.60 18.23 18.78 19.26 19.69 MH 0.19 27.56 10.92 13.18 15.03 16.58 17.89 19.03 20.01 20.91 21.71 22.42 23.06 0.25 46.00 11.25 13.70 15.75 17.50 19.00 20.32 21.48 22.51 23.44 24.27 25.05 0.32 69.66 11.45 14.02 16.20 18.08 19.71 21.15 22.43 23.58 24.62 25.56 26.41 ater Coil Notes 1. Fouling Factor = 0.00025 2. The following equations may be used in calculating Leaving ir Temperature (LT) and ater Temperature Difference (TD). LT = ET + ( k x 0.83 L/s ) TD = ET - LT = ( k (4.19)L/s) 3. Capacity based on 21 C entering air temperature and 82 C entering water temperature. Refer to correction factors for different entering conditions. Temperature Correction Factors for ater Pressure Drop (kpa) verage ater Temperature 93 88 82 77 71 66 60 54 49 43 Correction Factor 0.970 0.985 1.000 1.020 1.030 1.050 1.080 1.100 1.130 1.150 Temperature Correction Factors for Coil Capacity (k) Entering ater Minus Entering ir 22 27 33 38 44 50 55 61 67 72 Correction Factor 0.355 0.446 0.537 0.629 0.722 0.814 0.907 1.000 1.093 1.187 VV-PRC008-EN LHS 11

Performance Data Electrical Data LSEF Electric Coil k Guidelines Minimum to Maximum (PSC Motor Units) Fan Single-Phase Voltage Three-Phase Voltage Size Stages 120V 208V 240V 277V 347V 480V 208V 480V 600V 08SQ 1 0.5* 4.5* 0.5 6.0 0.5 6.0 0.5 6.0 0.5 6.0 0.5 6.0 0.5 6.0 1.0 6.0 1.5 6.0 2 0.5* 4.5 0.5 6.0 0.5 6.0 1.0 6.0 1.0 6.0 1.0 6.0 1.0 6.0 3.0 6.0 5.0 5.0 3** 09SQ 1 0.5* 4.5* 0.5 8.0 0.5 10.0 0.5 12.0 0.5 12.0 0.5 12.0 0.5 12.0 1.0 12.0 1.5 12.0 2 0.5* 4.5 0.5 8.0 0.5 10.0 1.0 12.0 1.0 12.0 1.0 12.0 1.0 12.0 3.0 12.0 4.5 10.0 3** 10SQ 1 0.5* 4.0* 0.5 7.5 0.5 8.0 0.5 11.0 0.5 15.0 0.5 18.0 0.5 13.0 1.0 18.0 1.5 18.0 2 0.5* 4.0* 0.5 7.5 0.5 8.0 1.0 11.0 1.0 15 1.0 18.0 1.0 13.0 2.0 18.0 3.0 18.0 3** *Special heater offering. **Three stages of electric heat available only with pneumatic controls. LSEF Electric Coil k Guidelines Minimum to Maximum (ECM Units) Fan Single-Phase Voltage Three-Phase Voltage Size Stages 120V 208V 240V 277V 347V 480V 208V 480V 600V 08SQ 1 0.5* 5.0* 0.5 6.0 0.5 6.0 0.5 6.0 0.5 6.0 0.5 6.0 1.0 6.0 2 0.5* 5.0* 0.5 6.0 0.5 6.0 1.0 6.0 1.0 6.0 1.0 6.0 3.0 6.0 3 09SQ 1 0.5* 4.5* 0.5 8.0 0.5 10.0 0.5 12.0 0.5 12.0 0.5 12.0 1.0 12.0 2 0.5* 4.5* 0.5 8.0 0.5 10.0 1.0 12.0 1.0 12.0 1.0 12.0 3.0 12.0 3 10SQ 1 0.5* 4.5* 0.5 8.0 0.5 9.0 0.5 12.0 0.5 18.0 0.5 14.0 1.0 18.0 2 0.5* 4.5* 0.5 8.0 0.5 9.0 1.0 12.0 1.0 18.0 1.0 14.0 2.0 18.0 3 *Special heater offering Notes: 1. Coils available with 24 VC magnetic or mercury contactors, load carrying P.E. switches, and P.E. switch with magnetic or mercury contactors. 2. vailable k increments are by 0.5 from 0.5 k to 8.0 k and by 1.0 k from 9.0 to 18.0 k. 3. Each stage will be equal in k output. 4. ll heaters contain an auto thermal cutout and a manual reset cutout. 5. The current amp draw for the heater elements is calculated by the formula below. 6. Only two stages of electric reheat available with Trane controls. Fan Electrical Performance (PSC) Maximum Fan Motor mperage (FL) Fan Size HP 115 VC 277 VC 347 VC 08SQ 1/3 5.5 2.5 1.8 09SQ 1/3 5.5 2.5 1.8 10SQ 2 x 1/8 9.4 3.5 3.0 Notes: 1. Electric Heat Units - Units with Primary Voltage of 208/60/1, 208/60/3 or 240/60/1 use 115 VC fan motors. 2. Electric Heat Units - Units with Primary Voltage of 277/60/1, 480/60/1 or 480/60/3 use 277 VC fan motors. 3. Electric Heat Units - Units with Primary Voltage of 347/60/1 or 575/60/3 use 347 VC fan motors. 4. Values are for standard, single-speed, permanent split capacitor type motors. Consult factory for non-standard motor performance. Fan Electrical Performance (ECM) Maximum Fan Motor mperage (FL) Fan Size HP 115 VC 277 VC 347 VC 08SQ 1/3 5.5 2.5 1.8 09SQ 1/3 5.5 2.5 1.8 10SQ 2 x 1/8 9.4 3.5 3.0 Formulas Minimum Circuit mpacity (MC) Equation MC = (motor amps + heater amps) x 1.25 Maximum Overcurrent Protection (MOP) Equation MOP = (2.25 x motor amps) + heater amps General Sizing Rules: If MOP = 15, then fuse size = 15 If MOP = 19, then fuse size = 15 with one exception. If heater amps x 1.25 > 15, then fuse size = 20. If MOP MC, then choose next fuse size greater than MC. Control fusing not applicable. Standard Fuse Sizes: 15, 20, 25, 30, 35, 40, 45, 50, and 60. Useful formulas: Cfm x TD k = 3145 k x 1000 3φamps = Primary Voltage x 3 TD = k x 3145 Cfm k = 1214 x L/s x TD 1φamps = TD = k 1214 x L/s k x 1000 Primary Voltage LHS 12 VV-PRC008-EN

Minimum Unit Electric Heat Cfm Guidelines (PSC) Unit Cfm k 08SQ 09SQ 10SQ 0.5 228 377 440 1 228 377 440 1.5 228 377 440 2 228 377 440 2.5 244 377 440 3 260 377 440 3.5 276 377 440 4 293 377 440 4.5 309 377 440 5 325 377 440 5.5 341 377 440 6 357 377 440 6.5 403 440 7 429 440 7.5 455 467 8 480 494 9 532 547 10 584 601 11 635 655 12 687 708 13 762 14 815 15 869 16 923 17 976 18 1030 Minimum Unit Electric Heat Cfm Guidelines (ECM) Unit Cfm k 08SQ 09SQ 10SQ 0.5 128 377 480 1 128 377 480 1.5 128 377 480 2 128 377 480 2.5 159 377 480 3 190 377 480 3.5 221 377 480 4 253 377 480 4.5 284 377 480 5 315 377 480 5.5 346 377 480 6 377 377 480 6.5 403 480 7 429 480 7.5 455 505 8 480 530 9 532 580 10 584 630 11 635 680 12 687 730 13 779 14 829 15 879 16 929 17 979 18 1029 Performance Data Electrical Data Minimum Unit Electric Heat L/s Guidelines (PSC) Unit L/s k 08SQ 09SQ 10SQ 0.5 108 178 208 1 108 178 208 1.5 108 178 208 2 108 178 208 2.5 115 178 208 3 123 178 208 3.5 130 178 208 4 138 178 208 4.5 146 178 208 5 153 178 208 5.5 161 178 208 6 168 178 208 6.5 190 208 7 202 208 7.5 215 220 8 227 233 9 251 258 10 275 284 11 300 309 12 324 334 13 360 14 385 15 410 16 435 17 461 18 486 Minimum Unit Electric Heat L/s Guidelines (ECM) Unit L/s k 08SQ 09SQ 10SQ 0.5 60 178 227 1 60 178 227 1.5 60 178 227 2 60 178 227 2.5 75 178 227 3 90 178 227 3.5 104 178 227 4 119 178 227 4.5 134 178 227 5 149 178 227 5.5 163 178 227 6 178 178 227 6.5 190 227 7 202 227 7.5 215 238 8 227 250 9 251 274 10 276 297 11 300 321 12 324 345 13 368 14 391 15 415 16 438 17 462 18 486 VV-PRC008-EN LHS 13

Performance Data coustics Discharge Sound Power (d) Discharge Sound Power (d) 0.5" Inlet 1.0" Inlet 2.0" Inlet 3.0" Inlet Fan Inlet Pressure (127 Pa) Pressure (254 Pa) Pressure (508 Pa) Pressure (762 Pa) Size Size Cfm L/s 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7 08SQ 8 170 80 54 49 45 37 28 22 55 53 47 40 33 31 58 62 55 45 41 37 58 63 58 49 46 40 250 118 57 52 48 42 33 27 58 56 50 43 36 33 60 63 56 47 42 38 60 64 59 50 46 41 330 156 60 56 52 46 37 31 61 59 54 47 39 36 63 64 58 50 43 39 63 65 60 52 46 42 410 193 63 60 56 50 41 36 64 62 57 50 42 38 65 65 59 52 44 41 65 67 62 53 46 43 490 231 66 64 60 54 45 41 67 65 60 54 45 41 68 66 61 54 45 42 68 68 63 55 46 44 09SQ 8x14 350 165 58 57 54 51 45 41 59 58 58 52 45 41 60 60 58 53 47 42 61 61 58 54 48 44 500 236 62 62 59 57 51 49 62 63 62 57 51 49 64 65 62 58 53 49 66 66 62 59 54 51 700 330 66 68 65 64 59 59 67 69 66 64 59 59 70 71 66 65 60 59 72 73 68 66 61 61 800 378 70 71 68 67 62 62 71 72 68 67 63 62 73 74 70 68 64 64 1000 472 75 76 73 72 68 67 75 76 73 72 68 67 75 76 73 73 69 69 10SQ 8x14 440 208 57 57 54 50 43 37 59 58 54 51 44 39 61 59 57 51 46 40 63 62 58 53 47 41 700 330 60 59 57 53 47 43 61 60 57 54 48 44 63 62 59 55 49 45 66 63 65 56 51 46 1100 519 66 67 64 62 57 55 68 68 65 62 57 56 69 69 66 63 58 56 1550 732 73 74 71 69 65 64 74 74 71 70 65 64 2100 991 81 81 78 78 74 73 1. ll data are measured in accordance with Industry Standard RI 880-98. 2. ll sound power levels, d re: 10-12 atts. Radiated Sound Power (d) Radiated Sound Power (d) 0.5" Inlet 1.0" Inlet 2.0" Inlet 3.0" Inlet Fan Inlet Pressure (127 Pa) Pressure (254 Pa) Pressure (508 Pa) Pressure (762 Pa) Size Size Cfm L/s 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7 08SQ 8 170 80 54 49 45 37 28 22 55 53 47 40 33 31 58 62 55 45 41 37 58 63 58 49 46 40 250 118 57 52 48 42 33 27 58 56 50 43 36 33 60 63 56 47 42 38 60 64 59 50 46 41 330 156 60 56 52 46 37 31 61 59 54 47 39 36 63 64 58 50 43 39 63 65 60 52 46 42 410 193 63 60 56 50 41 36 64 62 57 50 42 38 65 65 59 52 44 41 65 67 62 53 46 43 490 231 66 64 60 54 45 41 67 65 60 54 45 41 68 66 61 54 45 42 68 68 63 55 46 44 09SQ 8x14 350 165 58 53 47 39 32 27 59 56 56 43 37 34 62 63 61 52 45 42 64 65 62 54 49 45 500 236 62 57 51 44 36 30 63 59 57 46 39 36 65 64 62 53 46 44 67 66 63 55 50 47 700 330 68 63 56 50 40 33 68 64 58 50 42 39 69 65 62 53 47 46 71 67 64 56 51 50 800 378 70 66 59 52 44 41 71 67 63 55 48 47 72 69 65 57 52 51 1000 472 74 69 61 57 49 44 75 71 64 58 50 48 75 73 68 60 54 52 10SQ 8x14 440 208 61 56 49 42 33 27 62 59 52 45 40 38 65 60 60 50 46 46 66 63 61 58 50 49 700 330 62 58 51 45 37 31 64 61 55 48 43 41 68 64 62 53 48 48 70 66 67 57 52 51 1100 519 71 65 58 53 46 42 72 68 65 57 52 52 73 70 69 60 55 54 1550 732 77 71 64 60 54 52 79 74 70 63 58 57 2100 991 85 78 73 67 62 57 1. ll data are measured in accordance with Industry Standard RI 880-98. 2. ll sound power levels, d re: 10-12 atts. Fan Only Sound Power (d) Outlet Discharge Sound Power (d) Radiated Sound Power (d) Fan Static Octave and Octave ands Size (in. wg) Cfm L/s 2 3 4 5 6 7 2 3 4 5 6 7 08SQ 170 80 56 49 51 46 42 38 53 47 44 36 26 21 0.25 250 118 58 52 54 50 46 43 56 51 48 41 30 23 (63 Pa) 330 156 62 56 58 54 50 49 59 56 52 46 36 27 410 193 65 59 63 58 56 56 60 59 55 49 40 34 490 231 68 63 66 62 60 60 64 62 59 53 44 38 09SQ 350 165 60 56 54 51 46 41 57 51 44 38 24 20 0.25 500 236 64 60 59 57 52 49 61 55 48 42 30 23 (63 Pa) 700 330 69 66 65 64 59 58 66 61 55 49 38 29 800 378 72 68 68 67 62 61 68 64 58 52 42 32 1000 472 76 74 73 73 68 67 73 69 62 58 48 39 10SQ 440 208 58 57 54 51 44 38 62 57 48 41 29 22 0.25 700 330 60 60 58 56 49 45 64 60 51 45 33 24 (63 Pa) 1100 519 65 66 64 62 57 55 68 64 57 52 40 30 1550 732 71 72 70 70 65 64 74 70 63 59 48 37 2100 991 78 78 76 77 73 72 80 76 69 65 56 46 1. ll data are measured in accordance with Industry Standad RI 880-98. 2. ll sound power leves. d re: 10-12 atts. LHS 14 VV-PRC008-EN

Performance Data coustics Sound Noise Criteria (NC) Fan and 100% Primary Radiated Discharge NC/NC with NC Level ttenuator Fan Inlet Fan 0.5" 1.0" 2.0" 3.0" Fan 0.5" 1.0" 2.0" 3.0" Size Size Cfm L/s Only (127 Pa) (254 Pa) (508 Pa) (762 Pa) Only (127 Pa) (254 Pa) (508 Pa) (762 Pa) 08SQ 8 170 80 19 20 17/ 19/ 21/19 32/30 34/31 250 118 20 21 22/19 22/19 25/22 34/31 35/32 330 156 15 21 22 26/23 26/23 29/26 35/32 36/34 410 193 20 16 19 22 25 30/26 31/27 32/30 36/34 38/36 480 227 24 21 22 24 26 34/30 35/32 36/34 37/35 39/37 09SQ 8x14 350 165 16 17 19/17 21/20 31/27 3633 37/34 500 236 16 19 20 22 24 24/22 26/25 32/29 37/34 38/35 700 330 24 26 27 30 32 31/29 34/32 35/32 37/34 39/36 800 378 26 30 31 34 35/31 37/35 38/36 40/38 890 420 34 36 36 36 38/35 38/37 38/37 40/39 42/40 10SQ 8x14 440 208 15 19 26/24 25/21 29/25 35/29 36/30 700 330 16 15 16 19 20 30/27 27/24 31/27 37/31 42/36 900 425 24 25 26 27 32/30 34/30 34/30 39/34 44/37 1200 566 31 34 34 36/34 39/36 40/37 45/39 1500 708 38 41 40/39 42/40 46/42 1. represents NC levels below NC 15. 2. NC Values are calculated using modeling assumptions based on RI 885-98-02 ddendum. RI 885-98-02add DISCHRGE TRNSFER FUNCTION SSUMPTIONS: Octave and 2 3 4 5 6 7 Small ox (< 300 CFM) -24-28 -39-53 -59-40 Medium ox (300-700 CFM) -27-29 -40-51 -53-39 Large ox (> 700 CFM) -29-30 -41-51 -52-39 Subtract from terminal unit sound power to determine discharge sound pressure in the space. RI 885-98 RDITED TRNSFER FUNCTION SSUMPTIONS: Octave and 2 3 4 5 6 7 Type 2- Mineral Fiber Insulation -18-19 -20-26 -31-36 Total d reduction -18-19 -20-26 -31-36 Subtract from terminal unit sound power to determine radiated sound pressure in the space. VV-PRC008-EN LHS 15

Performance Data coustics Discharge Sound Power (d) Fan Only RI Conditions Fan Inlet Size Size Cfm L/s 2 3 4 5 6 7 08SQ 5, 6, 8 500 236 68 63 66 63 60 60 09SQ 6, 8, 8x14 950 448 75 73 71 71 67 66 10SQ 8, 8x14 1900 897 76 76 74 75 70 70 Radiated Sound Power (d) Fan Only RI Conditions Fan Inlet Size Size Cfm L/s 2 3 4 5 6 7 08SQ 5, 6, 8 500 236 64 62 59 54 45 38 09SQ 6, 8, 8x14 950 448 71 68 61 56 46 37 10SQ 8, 8x14 1900 897 78 74 67 63 54 43 Radiated Sound Power (d) Fan and Valve RI Conditions Fan Inlet Fan Fan Prim. Prim. 1.5" Inlet Pressure (381 Pa) Size Size Cfm L/s Cfm L/s 2 3 4 5 6 7 08SQ 5 500 236 250 118 67 64 58 53 44 40 6 500 236 400 189 70 65 60 54 44 41 8 500 236 500 236 68 66 61 54 46 42 09SQ 6 950 448 400 189 72 70 63 57 48 43 8 950 448 700 330 74 69 62 56 48 45 8x14 950 448 950 897 73 69 62 56 49 46 10SQ 8 1900 897 700 330 78 74 68 63 55 51 8x14 1420 670 1420 670 76 70 63 59 52 48 Notes: 1. ll data are measured in accordance with current Industry Standard RI 880, version 1998. 2. ll sound power levels, d re: 10-12 atts. LHS 16 VV-PRC008-EN

Performance Data coustics Inlet ttenuator ppurtenance Effects Discharge Sound Effect* (d) Radiated Sound Effect* (d) Fan 2 3 4 5 6 7 2 3 4 5 6 7 Matte-faced and foil-faced insulation, solid double-wall** 08SQ, 09SQ 0 0 0 1 0 0-1 -3-3 -7-7 -6 10SQ 2 2 2 2 2 2-2 -3-5 -10-12 -12 Closed-cell insulation 08SQ, 09SQ 0 1 0 0 0 0-1 -1-1 -4-6 -4 10SQ 2 2 2 2 2 2-1 -1-2 -5-9 -9 *dd to sound power, a negative effect represents a sound reduction, a positive effect represents a sound increase **Note: ttenuators on double-wall units have 1" foil-faced insulation. ll edges are encapsulated with metal. Cabinet Lining ppurtenance Effects Discharge Sound Effect* (d) Radiated Sound Effect* (d) Fan 2 3 4 5 6 7 2 3 4 5 6 7 Solid double-wall 08SQ, 09SQ 0 0 0 0 0 0-1 -2 2 11 17 19 10SQ 0 0 0 0 0 0 1 0 2 9 14 16 Closed-cell insulation 08SQ, 09SQ 0 0 0 0 0 0 2 3 6 7 8 12 10SQ 0 0 0 0 0 0 2 3 4 7 6 11 *dd to sound power, a negative effect represents a sound reduction, a positive effect represents a sound increase Heating Coil ppurtenance Effects Discharge Sound Effect* (d) Radiated Sound Effect* (d) Fan 2 3 4 5 6 7 2 3 4 5 6 7 Hot ater Coil** 08SQ, 09SQ 1 1 1 1 2 1 1 2 2 3 7 12 10SQ 1 2 2 1 2 1 1 1 1 2 4 8 Electric Heat** 08SQ, 09SQ -1-2 -1-1 -1-1 -3-1 1 1 7 7 10SQ 1 0-1 -1-1 0 2 4 3 4 6 9 * dd to sound power, a negative effect represents a sound reduction, a positive effect represents a sound increase **Radiated effect applies to fan only sound only. Do not apply to fan + valve sound. VV-PRC008-EN LHS 17

Dimensional Data LO-HEIGHT SERIES COOLING ONLY (LSCF) FN SIZES 08SQ & 09SQ FN SIZE 08SQ 09SQ 09SQ INLET SIZE INLET SIZE DISCHRGE DIMENSIONS Unit t VILILITY VILILITY H L C D Lbs NOMINL Ø (inches) NOMINL Ø (mm) (kg) 5, 6, 8 127, 152, 203 11.00" (279 mm) 26.00" (660 mm) 40.00" (1016 mm) 18.00" (457 mm) 10.00" (254 mm) 4.00" (102 mm) 4.00" (102 mm) 86 (39) 6, 8 152, 203 96 (44) 8 x 14 203 x 355 6.00" (152 mm) 4.50" (114 mm) 105 (47) Optional ttenuator 4. ctuator, Controller and D 32.00" (813 mm) Plenum Inlet 4. ctuator, Controller and Primary Optional ttenuator 18.00" (457 mm) ir Valve C 17.50" (445 mm) Rectangular Damper 8" x 14" (203 mm x 356 mm) Rectangular Damper Detail 5.00" (127 mm) L 4. ctuator, Controller and Fan Size Filter Size tten t Lbs (kg) 08SQ 10" x 10" x 1" 09SQ (254 mm x 254 mm x 25 mm) 10 (4.5) 7. NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange. Discharge Outlet 3. ottom ccess panel standard. TOP VIE 4. Control box enclosure provided with all control types. 5. ir valve centered between top and bottom panel. 6. ll high & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 7. Flange adds 2" to width and length of unit. 10.50" (267 mm) H LHS 18 DISCHRGE VIE 1.00" (25 mm) VV-PRC008-EN

Dimensional Data LO-HEIGHT SERIES COOLING (LSCF) FN SIZE 10SQ FN INLET SIZE INLET SIZE SIZE VILILITY NOMINL Ø (INCHES) NOMINL Ø (mm) 10SQ 10SQ 8 8 x 14 203 203 x 356 DISCHRGE DIMENSIONS H L 48.00" (1219 mm) 36.00" (914 mm) 38.00" (965 mm) UNIT T C D T LS (kg) 4.00" (102 mm) 20.00" (508 mm) 120 (54) 6.00" (152 mm) 17.50" (445 mm) 130 (59) Optional ttenuator 2. O ator ed 8. 8. ctuator, Controller and 32.00" 32.00" (813 mm) (813 mm) 18.00" (457 mm) Optional ttenuator D Plenum Inlet Primary Plenum Inlet Optional ttenuator Rectangular Damper Detail Rectangular Damper 8" x 14" (203 mm x 356 mm) 17.50" (445 mm) 5.00" (127 mm) L 9. Fan Size 10SQ Filter Size 10" x 16" x 1" (254 mm x 406 mm x 25 mm) tten t Lbs (kg) 20 (9) NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. Discharge Outlet 2. Filter location with optional ttenuator. 3. ttenuator-factory assembled, field installed. 4. ir valve centered between top and bottom panel. TOP VIE 5. Heating coil uninsulated. External insulation may be field supplied and installed as required. 6. ll high & low voltage controls have same-side NEC jumback clearance. (Left-hand shown, right-hand available.) 7. ottom ccess panel standard. H 10.50" (267 mm) 8. Control box enclosure provided with all control types. 9. Flange adds 2" to width and length of unit. DISCHRGE VIE VV-PRC008-EN LHS 19

Dimensional Data LO-HEIGHT SERIES HOT TER (LSF) FN SIZES 08SQ & 09SQ FN SIZE 08SQ 09SQ 09SQ INLET SIZE VILILITY NOMINL Ø INLET SIZE NOMINL Ø (mm) 6, 8 152, 203 8 x 14 203 x 355 H DISCHRGE DIMENSIONS L 26.00" (660 mm) 40.00" (1016 mm) 18.00" (457 mm) C D Unit t Lbs (kg) 105 (48) 114 (52) Optional ttenuator 4. ctuator, Controller and Fan Controls located in Enclos 32.00" (813 mm) D Plenum Inlet 4. ctuator, Controller and Primary Optional ttenuator 18.00" (457 mm) ir Valve C 17.50" (445 mm) Rectangular Damper 8" x 14" (203 mm x 356 mm) Rectangular Damper Detail 5.00" (127 mm) L ctuator, Controller and Fan Size 08SQ 09SQ Filter Size 10" x 10" x 1" (254 mm x 254 mm x 25 mm) tten t Lbs (kg) 10 (4.5) 8. TOP VIE ater Coil 6.80" (173 mm) NOTES: Discharge Outlet 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Flanged discharge outlet accepts up to a 1" (25 mm) duct flange. 3. ottom ccess panel standard. 4. Control box enclosure provided with all control types. 5. ir valve centered between top and bottom panel. 10.50" (267 mm) H 6. Heating coil uninsulated. External insulation may be field supplied and installed as required. 7. ll high & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 8. Flange adds 2" to width and length of unit. LHS 20 DISCHRGE VIE 1.00" (25 mm) VV-PRC008-EN

Dimensional Data LO-HEIGHT SERIES HOT TER (LSF) FN SIZE 10SQ FN INLET SIZE INLET SIZE DISCHRGE DIMENSIONS SIZE VILILITY H L NOMINL Ø (INCHES) NOMINL Ø (mm) 10SQ 10SQ 8 8 x 14 203 203 x 356 11.00" (279 mm) 48.00" (1219 mm) 36.00" (914 mm) 38.00" (965 mm) C 6.00" (152 mm) D UNIT T T LS (kg) 146 (66) ator d tor d 8. ctuator, Controller and 8. ctuator, Controller and 32.00" 32.00" (813 mm) (813 mm) 2. 18.00" (457 mm) Optional ttenuator D Plenum Inlet Primary Optional ttenuator Plenum Inlet Rectangular Damper Detail C Rectangular Damper 8" x 14" (203 mm x 356 mm) 17.50" (445 mm) 8. ctuator, Controller and L 5.00" (127 mm) Fan Size Filter Size tten t Lbs (kg) 10SQ 10" x 16" x 1" (254 mm x 406 mm x 25 mm) 20 (9) Discharge Outlet TOP VIE 6.80" (173 mm) NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Filter location with optional ttenuator. 3. ttenuator-factory assembled, field installed. 4. ir valve centered between top and bottom panel. 5. Heating coil uninsulated. External insulation may be field supplied and installed as required. 6. ll high & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 7. ottom ccess panel standard. 8. Control box enclosure provided with all control types. 10.50" (267 mm) H DISCHRGE VIE VV-PRC008-EN LHS 21

H Fan-Powered Dimensional Data COIL INFORMTION FOR LO-HEIGHT SERIES 1-RO COIL FN SIZE COIL CONNECTION L H 08SQ.875" (22 mm) O.D. 7.75" (197 mm) 1.50" (38 mm) 18.00" (457 mm) 10.00" (254 mm) 6.80" (173 mm) 09SQ 10SQ 38.00" (965 mm) 3.40" (86 mm) INLET IR FLO 7.81" (198 mm) IR FLO CCESS PNEL Fan Size 08SQ 09SQ INTERNL VOLUME GL (L) OPERTING EIGHT LS (KG) 0.07 (.28) 10.4 (4.7) 1.00" (25 mm) 10SQ 0.15 (.59) 16.4 (7.4) 2.00" (51 mm) NOTES: 1. Location of coil connections is determined by facing air stream. L.H. coil connections shown, R.H. opposite. 2. Coil furnished with stub sweat connections. 3. Coils can be field-rotated for opposite connections. Note: ater inlet is always the bottom connection. 4. ccess panel is standard. LHS 22 VV-PRC008-EN

H Fan-Powered Dimensional Data COIL INFORMTION FOR LO-HEIGHT SERIES 2-RO COIL FN SIZE COIL CONNECTION L H 08SQ.875" (22 mm) O.D. 6.25" (159 mm) 2.00 (51 mm) 18.00" (457 mm) 10.00" (254 mm) 6.75" (171 mm) 09SQ 10SQ 38.00" (965 mm) L 3.40" (86 mm) INLET 7.81" (198 mm) IR FLO IR FLO INLET CCESS PNEL Fan Size INTERNL VOLUME GL (L) OPERTING EIGHT LS (KG) 1.00" (25 mm) 08SQ 09SQ 0.11 (.45) 11.1 (5.0) 2.00" (51 mm) 10SQ 0.24 (.94) 23.0 (10.4) NOTES: 1. Location of coil connections is determined by facing air stream. L.H. coil connections shown, R.H. opposite. 2. Coil furnished with stub sweat connections. 3. Coils can be field-rotated for opposite connections. Note: ater inlet is always the bottom connection. 4. ccess panel is standard. VV-PRC008-EN LHS 23

Dimensional Data LO-HEIGHT SERIES ELECTRIC HET (LSEF) FN SIZES 08SQ & 09SQ FN INLET SIZE INLET SIZE DISCHRGE DIMENSIONS Unit t SIZE VILILITY VILILITY H L C D Lbs NOMINL Ø (INCHES) NOMINL Ø (mm) (kg) 08SQ 5, 6, 8 127, 152, 203 11.00" (279 mm) 26.00" (660 mm) 40.00" (1016 mm) 14.00" (356 mm) 9.00" (229 mm) 4.00" (102 mm) 4.00" (102 mm) 101 (45.8) 09SQ 6, 8 152, 203 09SQ 8 x 14 203 x 355 6.00" (152 mm) 4.50" (114 mm) 120 (54.4) tional ttenuator 4. ctuator, Controller and 32.00" (813 mm) 4. D Plenum Inlet ctuator, Controller and Primary Optional ttenuator 18.00" (457 mm) ir Valve C 17.50" (445 mm) Rectangular Damper 8" x 14" (203 mm x 356 mm) Rectangular Damper Detail 5.00" (127 mm) L 4. ctuator, Controller and 8. Fan Size 08SQ 09SQ Filter Size 10" x 10" x 1" (254 mm x 254 mm x 25 mm) tten t Lbs (kg) 10 (4.5) 20.00" (508 mm) Electric Heater TOP VIE NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Flanged discharge outlet accepts up to 1" (25 mm) duct flange. 3. ottom ccess panel standard. 4. Control box enclosure provided with all control types. Discharge Outlet 5. ir valve centered between top and bottom panel. 6. Heating coil uninsulated. External insulation may be field supplied and installed as required. 7. ll hight & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 10.50" (267 mm) H 8. Flange adds 2" to width and length of unit. LHS 24 DISCHRGE VIE VV-PRC008-EN

Dimensional Data LO-HEIGHT SERIES ELECTRIC (LSEF) FN SIZE 10SQ FN INLET SIZE INLET SIZE SIZE VILILITY VILILITY NOMINL Ø (INCHES) NOMINL Ø (mm) 10SQ 8 203 10SQ 8 x14 203 x 356 H 11.00" (279 mm) 48.00" (1219 mm) DISCHRGE DIMENSIONS L 36.00" (914 mm) 25.30" (643 mm) UNIT T C D T LS (kg) 6.00" (152 mm) 155 (70.3) Optional ttenuator 8. ctuator, Controller and 8. ctuator, Controller and 32.00" 32.00" (813 mm) (813 mm) Optional ttenuator Optional ttenuator 18.00" (457 mm) D Plenum Inlet Primary C Plenum Inlet Rectangular Dam Rectangular Damper 8" x 14" (203 mm x 356 mm) 8. 17.50" (445 mm) ctuator, Controller and L 5.00" (127 mm) 9. Fan Size 10SQ Filter Size 10" x 16" x 1" (254 mm x 406 mm x 25 mm) tten t (Qty 2) Lbs (kg) 20 (9.1) 24.00" (610 mm) Terminal ox Heater Plenum rea 11.00" (279 mm) 8.00" (203 mm) NOTES: 1. llow a minimum 6" (152 mm) plenum inlet clearance for unducted installations. 2. Filter location with optional ttenuator. 3. ttenuator-factory assembled, field installed. Discharge Outlet TOP VIE 4. ir valve centered between top and bottom panel. 5. Heating coil uninsulated. External insulation may be field supplied and installed as required. 6. ll high & low voltage controls have same-side NEC jumpback clearance. (Left-hand shown, right-hand available.) 7. ottom ccess panel standard. 8. Control box enclosure provided with all control types. H 10 (267 9. Flange adds 2" to width and length of unit. DISCHRGE VIE VV-PRC008-EN LHS 25

Mechanical Specifications MODELS LSCF, LSF, and LSEF Low-height series fan-powered terminal units. LSCF Cooling Only LSF ith Hot ater Coil LSEF ith Electric Coil CSING 22-gage galvanized steel. Hanger brackets, bottom access, and plenum inlet filter are provided as standard. GENCY LISTING The unit is UL and Canadian UL Listed as a room air terminal unit. Control # 9N65. RI 880 Certified. INSULTION 1/2" (12.7 mm) Matte-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with ½-inch, 1.75 lb/ft 3 (12.7 mm, 28.03 kg/m 3 ) composite density glass fiber with a high-density facing of 4.0 lb/ft 3 (64 kg/m 3 ). The insulation R-Value is 1.9. The insulation is UL listed and meets NFP-90 and UL 181 standards. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Matte-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1-inch, 1.55 lb/ft 3 (25.4 mm, 24.8 kg/m 3 ) composite density glass fiber with a high-density facing of 4.0 lb/ft 3 (64 kg/m 3 ). The insulation R-Value is 3.85. The insulation is UL listed and meets NFP- 90 and UL 181 standards. There are no exposed edges of insulation (complete metal encapsulation). 1/2" (12.7 mm) Foil-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with ½-inch, 2.0 lb/ft 3 (12.7 mm, 32.04 kg/m 3 ) density glass fiber with foil facing. The insulation R-Value is 2.2. The insulation is UL listed and meets NFP-90 and UL 181 standards as well as bacteriological standard STM C 665. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Foil-faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1-inch, 2.0 lb/ft 3 (25.4 mm, 32.04 kg/m 3 ) density glass fiber with foil facing. The insulation R-Value is 4.3. The insulation is UL LHS 26 listed and meets NFP-90 and UL 181 standards as well as bacteriological standard STM C 665. There are no exposed edges of insulation (complete metal encapsulation). 1" (25.4 mm) Double-wall Insulation The interior surface of the unit casing is acoustically and thermally lined with a 1-inch, 2.1 lb./ft 3 (25.4 mm, 33.6 kg/m 3 ) composite density glass fiber with high-density facing. The insulation R-value is 3.0. The insulation is UL listed and meets NFP- 90 and UL 181 standards. The insulation is covered by an interior liner made of 26-gage galvanized steel. ll wire penetrations are covered by grommets. There are no exposed edges of insulation (complete metal encapsulation). 3/8" (9.5 mm) Closed-cell Insulation The interior surface of the unit casing is acoustically and thermally lined with 3/8-inch, 4.4 lb/ft 3 (9.5 mm, 40.0 kg/m 3 ) closed-cell insulation. The insulation is UL listed and meets NFP-90 and UL 181 standards. The insulation has an R-value of 1.4. There are no exposed edges of insulation (complete metal encapsulation). PRIMRY IR VLVE ir Valve Round The primary air inlet connection is an 18-gage galvanized steel cylinder sized to fit standard round duct. multiple-point, averaging flow sensing ring is provided with balancing taps for measuring +/-5% of unit cataloged airflow. n airflow-versus-pressure differential calibration chart is provided. The damper blade is constructed of a closed-cell foam seal that is mechanically locked between two 22-gage galvanized steel disks. The damper blade assembly is connected to a cast zinc shaft supported by selflubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over-stroking. t 4.0 in. wg, air valve leakage does not exceed 1% of cataloged airflow. ir Valve Rectangular Inlet collar is constructed of 22-gage galvanized steel sized to fit standard rectangular duct. n integral multiple-point, averaging flow-sensing ring provides primary airflow measurement within +/ -5% of unit cataloged airflow. Typical inlet conditions: flex duct and 90 inlets to the damper. Damper is 22-gage galvanized steel with polyolefin foam seal. The damper blade assembly is connected to a solid metal shaft supported by self-lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over-stroking. t 3.0 in. wg, air valve leakage does not exceed 44 cfm (21 L/s). Fan Inlet Combinations: LSXF Inlet 08Q 09SQ 10SQ 5" X 6" X X 8" X X X 8x14" X X FN MOTOR PSC Single-speed, direct-drive, permanent split capacitor type. Thermal overload protection provided. Motors will be designed specifically for use with an open SCR. Motors will be single-speed with standard SCR for speed control. Motors will accommodate anti-backward rotation at start up. Motor and fan assembly is isolated from terminal unit. ECM Electrically Commutated Motor is desinged for high-efficient operation with over 70% efficiency throughout the operating range. FN SPEED CONTROL Variable Speed Control Switch (SCR) The SCR speed control device is provided as standard and allows the operator infinite fan speed adjustment so the fan output may be modified to achieve exact cfm requirements. TRNSFORMER The 50 V transformer is factoryinstalled in the fan control box to provide 24 VC for controls. POER DISCONNECT The power disconnect is provided as standard and allows the operator to turn the unit on or off by toggling to the appropriate setting. This switch breaks both legs of power to the fan and the electronic controls (if applicable). Not provided on LSEF with pneumatic controls OUTLET CONNECTION Flanged Connection rectangular opening on the unit discharge to accept a 90 flanged ductwork connection. FILTER 1" (25 mm) filter is provided on the plenum inlet and attaches to the unit with a filter frame. VV-PRC008-EN

Mechanical Specifications CCESS PNEL Internal access to unit is achieved through the removable bottom access panel. HOT TER COIL ater Coils factory-installed on the plenum inlet. The coil has 1-row with 144 aluminumplated fins per foot (.305 m) and, if needed, 2-row with 144 aluminumplated fins per foot (.305 m). Full fin collars provided for accurate fin spacing and maximum fin-tube contact. The 3/8" (9.5 mm) OD seamless copper tubes are mechanically expanded into the fin collars. Coils are proof tested at 450 psig (3102 kpa) and leak tested at 300 psig (2068 kpa) air pressure under water. Coil connections are brazed with left-hand configuration. ELECTRIC HET COIL The electric heater is a factory-provided and -installed, UL recognized resistance open-type heater. It also contains a disc-type automatic pilot duty thermal primary cutout, and manual reset load carrying thermal secondary device. Heater element material is nickel-chromium. The heater terminal box is provided with 7/8" (22 mm) knockouts for customer power supply. Terminal connections are plated steel with ceramic insulators. Heater control access is on the discharge side of the unit. ll fanpowered units with electric reheat are single-point power connections. ELECTRIC HET OPTIONS Magnetic Contactor n optional electric heater 24-volt contactor for use with direct digital control (DDC) or analog-electronic controls. Mercury Contactor n optional electric heater 24-volt contactor for use with direct digital control (DDC) or analog-electronic controls. P.E. Switch with Magnetic Contactor This optional switch and magnetic contactor is for use with pneumatic controls. P.E. Switch with Mercury Contactor This optional switch and mercury contactor is for use with pneumatic controls. Switch n optional air pressure device designed to disable the heater when the system fan is off. Power Fuse If power fuse is chosen with a unit with electric heat, then a safety fuse located in the line of power of the electric heater to prevent power surge damage to the electric heater. ny electric heat unit with a calculated MC greater than or equal to 30 will have a fuse provided Disconnect Switch n optional factory-provided door interlocking disconnect switch on the heater control panel disengages primary voltage to the terminal. UNIT CONTROLS SEQUENCE OF OPERTION The controller will start and run the fan continuously during the occupied mode and intermittently during the unoccupied mode. Upon a further call for heat, any hot water or electric heat associated with the unit is enabled. DIRECT DIGITL CONTROLS DDC ctuator Trane 3-wire, 24-VC, floating-point control actuator with linkage release button. Torque is 35 in-lb minimum and is non-spring return with a 90-second drive time. Travel is terminated by end stops at fully-opened and -closed positions. n integral magnetic clutch eliminates motor stall. Direct Digital Controller The microprocessor based terminal unit controller provides accurate, pressureindependent control through the use of a proportional integral control algorithm and direct digital control technology. The controller, named the Unit Control Module (UCM), monitors zone temperature setpoints, zone temperature and its rate of change, and valve airflow using a differential pressure signal from the pressure transducer. dditionally, the controller can monitor either supply duct air temperature or CO 2 concentration via appropriate sensors. The controller is provided in an enclosure with 7/8" (22 mm) knockouts for remote control wiring. Trane UCM zone sensor is required. DDC Zone Sensor The UCM controller senses zone temperature through a sensing element located in the zone sensor. In addition to the sensing element, zone sensor options may include an externally-adjustable setpoint, communications jack for use with a portable edit device, and an override button to change the individual controller from unoccupied to occupied mode. The override button has a cancel feature that will return the system to unoccupied. ired zone sensors utilize a thermistor to vary the voltage output in response to changes in the zone temperature. iring to the UCM controller must be 18- to 22-awg. twisted pair wiring. The setpoint adjustment range is 50 88ºF (10 31 C). Depending upon the features available in the model of sensor selected, the zone sensor may require from a 2-wire to a 5-wire connection. ireless zone sensors report the same zone information as wired zone sensors, but do so using radio transmitter technology. Therefore with wireless, wiring from the zone sensor to the UCM is unnecessary. Digital Display Zone Sensor with Liquid Crystal Display (LCD) The digital display zone sensor contains a sensing element, which sends a signal to the UCM. Liquid Crystal Display (LCD) displays setpoint or space temperature. Sensor buttons allow the user to adjust setpoints, and allow space temperature readings to be turned on or off. The digital display zone sensor also includes a communication jack for use with a portable edit device, and an override button to change the UCM from unoccupied to occupied. The override button has a cancel feature, which returns the system to unoccupied mode. Trane LonTalk The controller is designed to send and receive data using SCC LonTalk profile. Current unit status conditions and setpoints may be monitored and/or edited from any of several LonTalk-compatible systemlevel controllers NLOG ELECTRONIC CONTROLS nalog ctuator Trane 3-wire, 24-VC, floating-point control actuator with linkage release button. Torque is 35 in-lb minimum and is non-spring return with a 90-second drive time. Travel is terminated by end stops at fully-opened and -closed positions. n integral magnetic clutch eliminates motor stall. nalog Electronic Controller The controller consists of a circuit board that offers basic VV unit operation and additional override functions and operates using 24 VC power. The VV-PRC008-EN LHS 27