Base Power Infeed Installation for Training Tables with Modular Table Power System

Similar documents
Assembly and Modular Table Power System Installation Instructions for Train Tables

Power In - Pathways Technology Wall

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

C35. Assembly Instructions. Mobius Floor Lamp & C Page 1 of 7. Prepare Base (Figures 1& 2)

Assembly Guide ELECTRIC. Model Numbers: C1. (English) /14/11

Universal Storage - Storage/Wardrobe/Combo Cabinets/Lateral Files

INSTALLATION INSTRUCTIONS SEMI-HIDDEN WINCH MOUNT Part Number:70005 Application: Ford Super Duty

Roller Shades CORD LOOP. Head Rail, Fascia and No Head Rail. Installation & Care Instructions

assembly guide ELECTRIC Model Numbers: Estimated time required for assembly: 1 Hour (English) /02/10

INFINITY MULTA SERIES

Assembly of kick TM Utility Poles

Haworth prices in this book will increase on March 1, 2017 by 4% Intuity Benching North America Specification Guide / Price List June 2015

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON

INTERWORKS EQ. Table of Contents. Panel System. Interworks EQ Kimball Legacy. Price List Effective Dates: Pricing Revision

C35 Mobius Floor Lamp & C Page 1 of 7

Easy Cover. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

Universal Storage - Drawer and Overfile Stack Units

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Rollstar Shade Installation Instructions

Installation Instructions Studio Makeup Station

INSTALLATION & OWNER S MANUAL

Woda-Sci System Installation Parts Set

Cetra Assembly Instructions

Draper Platform Adaptation Bundle

Installation Instructions Table of Contents

Cetra. Ceiling Power Entry Installation (AEC1, AEC14, or AEC16)

SYSTIMAX 360 FTP Evolve Panel Instructions

Anthro Mobile Device Charging Carts and Cabinets Owners Manual

Installation Instructions Supertop NX Twill

Table of Contents Next FLO-SAFE Manifold System Pre-Installation Kit Matrx Toll-Free: Technical Support: Fax: Rev.

Spectra C3 Light Bar Installation Instructions

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

WAVETRAX USER MANUAL

Solar Dolly. Assembly Manual

Mizer Single Pump and Starter Box

INSTALLATION & OWNER S MANUAL

SERVICE INSTRUCTIONS KEATING keatingofchicago.com

Solar & Roller Shades

ZIP LIGHT LED LUMINAIRE

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Line Lock Package, Mustang GT/GT500, 2007 PACKING LIST

LED IMPORTANT SAFETY INSTRUCTIONS

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

INSTALLATION INSTRUCTIONS Mitsubishi Lancer Evolution VIII / IX Fuel Surge Tank Kit Document#

Installation Instructions Capacity 10,000 lbs. DP10 (200 Series Lift)

626F Exit Device Trim Installation Instructions

A B C D E F. Tools Required (supplied by others)

Installing Ignition Coil relay

Installation Instructions Skylight FlexShades by Draper

INSTALLATION INSTRUCTIONS

Plasma Dual Swing-Out (PDS Series) Wall Mount

HP Modular Cooling System 200/100 Options Installation Guide

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

w w w. h d o n l i n e s h o p. d e LAYBACK LICENSE PLATE AND TURN SIGNAL RELOCATION KIT INSTALLATION GENERAL -J03892 REV Kit Number

INSTALLATION INSTRUCTIONS

HP10220 KIT. See application guide for proper fitment.

Owner s Manual Electric Swivel

Installation Notes. PlayPorTT Kiosk Anti-Tip Safety Cable. (p/n )

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

Trackstar Motorized Folding Shade Installation Instructions

5830 Skylight, Solar Smart Retrofit Installation

INSTALLATION GUIDES OUTDOOR LIVING

ZoneEx Modular Wiring System

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

4-WHEEL CART ASSEMBLY INSTRUCTIONS Mission Oaks Blvd., Camarillo, CA Visit our Web site at

INSTALLATION INSTRUCTIONS

SALEEN SPEEDLAB BOOST AND WATER TEMPERATURE GAUGE POD KIT

INSTALLATION INSTRUCTIONS

How to remove and replace the Foonf/Fllo fabric

MF-12A MF-12A OWNER S MANUAL MF-12A PINSPOTTER MACHINERY DIVISION

Top Down Rollstar Shade Installation Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

ACL 780/781 Economy Combo Tester

Operation Manual Image

Replacement Top Hardware Installation Instructions

INSTALLATION INSTRUCTIONS NEON RGB

! DANGER Lb. Winch Mounting Instructions. Tools required: Before You Start. Assembly Instructions. General Information. Manual No.

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

TECHNICAL SPECIFICATIONS. CAPACITY per slot width 1ʺ 1.25ʺ 1.5ʺ HKPX2VC/A 2 modules devices HKPY2VC/A 3 modules devices

Installation, Maintenance and Service Manual Power Cord

Quick Start Guide Compact 22 LE ( s/n & up)

GENUINE PARTS INSTALLATION INSTRUCTIONS

Universal Splice Tray Installation Instructions

Classic Light Bar Mustang

xtablet T7000 Vehicle Mount Kit

INSTALLATION GUIDE PRISONER TRANSPORT LIGHTING. pro-gard.com STRONG RELIABLE SECURE

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

Installation Instructions

2 4 L R I G I D L E D L E D S I M U L AT E D N E O N I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY!

HANDY GATE ASSEMBLY, INSTALLATION AND OPERATING INSTRUCTIONS

FAX

Technical Support (707)

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

PROCEDURE STEPS: WARNING:

and Original Series Pickup Lift Mounting Instructions Fullsize Nissan Titan Trucks present T-420 BOLT-ON GUSSET PART#5257

Elegance Electrician s Installation Guide

Transcription:

Base Power Infeed Installation for Training Tables with Modular Table Power System Topic Table of Contents General Safety Warnings Base Power Infeed Usage Electrical Circuits Base Power Infeed - 0 Amp Plug Base Power Infeed - Hardwire Hardwire Power Infeed Tether Base Power Infeed Assemblies Page 1 1 1 3 CABLE LENGTH 1" MAX. 1. For use in indoor, dry locations only.. Read and install in accordance with all assembly directions. 3. Only connect to products labeled "Modular Table Power System" by Steelcase. 4. Do not modify or strain cables. If damaged, remove from service immediately. 5. Disconnect modular electrical connections before servicing or reconfiguring tables. 6. Tables must be held together with ganging hardware as described in this document, and NOT held together solely by electrical components. 7. Cable clamps must be no more than 1" from modular cable end connector or receptacle. Installing Hardwire Infeed Installing 0 Amp Plug Infeed 3-4 5-6 1" MAX. Base Power Infeed Usage A base power infeed is required to provide power to Modular Table Power Kits. All power infeeds have a female connector. Two versions of infeeds are available: -0 Amp plug - The 0-amp plug infeed is used when reconfigurability is needed, and does not require an electrician. The plug infeed can only be used with circuit-1 receptacles. -Hardwire - When the installation is permanent or local electrical codes are restrictive, the hardwire base power infeed is available. This infeed must be installed by a licensed electrician in compliance with all local and national codes. The hardwire infeed can be used with circuit-1 and circuit- receptacles. Electrical Circuits Runner Non-folding Plug and Play Table Train Tables Akira Folding and Fixed Tables The modular table power kit is a 0 Amp, 4-wire, -circuit system. The 0 Amp plug infeed allows up to 13 circuit-1 duplex receptacles. The hardwire infeed allows up to 13 duplex receptacles per circuit for a total of 6. The duplex receptacle(s) in the table power kit and every two simplex receptacles from the desktop module count against the 13 duplex receptacles allowed for each circuit. Receptacle faces on the Modular Table Power Kits are marked I, for circuit 1 and II, for circuit. If you have a problem, question, or request, call your local dealer, or Coalesse at 1.800.67.6770 Or visit our website: www.coalesse.com 015 Coalesse San Francisco, California U.S.A. Printed in U.S.A. Page 1 of 6

Base Power Infeed - 0 Amp Plug The plug base power infeed is a single-circuit (circuit 1) power infeed with 4" of rubber cord and a 0-Amp plug on one end coupled to 48" of flexible steel conduit with a female modular connector on the other end. Base Power Infeed - Hardwire The hardwire base power infeed is a two-circuit (circuits 1 & ) flexible steel conduit with a 4-wire pigtail for hardwire connection on one end and a female modular connector on the other end. Hardwire Power Infeed Tether A flexible braided steel tether is included with the hardwire power infeed kit. The tether anchors the table to the building, preventing disengagement of electrical connections. The first table in a series of tables connected with power, must be anchored in place with the tether. The tether provided is 1" shorter than the hardwire infeed cable. If the hardwire infeed cable is shortened, the tether must also be shortened to maintain the structural connection. The tether length between its connection to the table and the building must always be shorter than the hardwire infeed length between its modular connection and the building. An extra loop and crimp are provided for the cut end of the tether. Neutral Ground Not Used Hot 1 CIRCUIT 1 0 AMP PLUG SCHEMATIC White, 1 GA Green or no coating, 1 GA Red Black, 1 GA Note: all electrical installations must be reviewed with the local authority for compliance with local code, and must be performed by a qualified person in accordance with codes and regulations applicable at the installation site. Base Power Infeed - 0 Amp Plug Neutral Ground Hot Hot 1 White, 1 GA Green or no coating, 1 GA Red, 1 GA Black, 1 GA Base Power Infeed - Hardwire CIRCUIT 1 CIRCUIT HARDWIRE SCHEMATIC Hardwire Power Infeed Tether Page of 6

Base Power Infeed Assemblies 0 Amp Plug Hardwire SHIPPED COMPONENTS: - 1 cable/cord assembly - 1 hardware kit SHIPPED COMPONENTS: - 1 cable assembly - 1 hardware kit HARDWARE: - #10 phillips head screws/black - cushioned clamps TOOLS REQUI: - drill and.157" dia. drill bit - # phillips head driver HARDWARE: - 1 tether assembly - 1 thumb screw - #10 philips head screws/black - Cushioned Clamps - 1 loop - 1 crimp TOOLS REQUI: - drill and.157" dia. drill bit - # phillips head driver - crimping tool required if tether is shortened. FEMALE CONNECTOR Runner Table Shown TETHER 3 HARDWIRE INFEED TO BUILDING POWER SUPPLY OPTIONAL VERTICAL WIRE MANAGER Installing Hardwire Infeed 1. Determine location of building power supply.. Determine which table will be first in the series and where power infeed will connect to modular cable. Note: All power infeed cables have a female connector. 3. Determine power infeed cable routing. Recommended routings include: - Along table leg - Through optional vertical wire manager (Runner & Akira only) - Directly into wall CONDUIT SNAP-CLIP 6 4 TIP: Place a shim under rug to allow a finger hold when assembled unit is ready to upright. 4. Carefully place table upside down onto rug or other soft, clean surface. 5. Remove ganging hardware from corner of table where power infeed will be connected. MALE CONNECTOR 5 FEMALE CONNECTOR GANGING HARDWARE 6. Remove modular cable end from conduit snap-clip at corner of table where infeed will be connected; then remove snap-clip. Note: Snap-clip is not required for fastening modular cable. Page 3 of 6

Installing Hardwire Infeed (continued) Male end of Modular Table Power Cable Female end of Base Power Infeed Cable 7. Insert thumb screw through tether loop. 8. Locate threaded insert near end of table where infeed will be connected. Attach tether to table by fastening tether loop and thumb screw assembly into threaded insert. Table Run Note: Latches fully engaged. Building Power Supply THUMB SCREW TETHER LOOP 7 TETHER LOOP & THUMB SCREW ASSEMBLY. Connect power infeed to modular cable. - Match like colors only. (Green-to-Green, Red-to-Red, Black-to-Black and White-to-White). Push connectors together until both latches engage. 10. Relocate conduit clamp. Mark mounting hole location. - Do not allow more than 1" of cable between modular connector and clamp. 11. Wrap first cushioned clamp around Base Power Infeed conduit between shrink-wrapped ground wire and ID label. Wrap second clamp approximately 1/4" from first, but with mounting hole location on opposite side of the conduit. Mark mounting hole locations. - Ensure both cushioned conduit clamps are positioned per artwork shown. Note: Orient colors on both connectors to match. Note: Cable inside bend radius must not be less than 1.50". 1. Drill pilot holes for clamps.157" diameter by.50" deep, then fasten clamps. 13. Carefully flip tables upright into use position, and make ganging connection(s). 14. Securely anchor tether to building. CONDUIT CLAMP 10 1 CONNECTION TO 11 1 11 CUSHIONED CLAMPS ID LABEL.5" TETHER LOOP & THUMB SCREW ASSEMBLY 8 15. Connect hardwire infeed to building power. - Connection must be performed by a qualified person following local and national electrical codes. SHRINK-WRAPPED GROUND WIRE 11 Page 4 of 6

Installing 0 Amp Plug Infeed 1. Determine location of power outlet in wall or floor of building.. Determine which table will be first in the series and where power infeed will connect to modular cable. Note: All power infeed cables have a female connector. 3. Determine power infeed cable routing. Recommended routings include: - Along table leg - Through optional vertical wire manager (Runner & Akira only) - Directly into wall 4. Carefully place table upside down onto rug or other soft, clean surface. FEMALE CONNECTOR Runner Table Shown OPTIONAL VERTICAL WIRE MANAGER TO BUILDING POWER SUPPLY 5. Remove ganging hardware from corner of table where power infeed will be connected. 6. Remove modular cable end from conduit snap-clip at corner of table where infeed will be connected, then remove snap-clip. Note: Snap-clip is not required for fastening modular cable. 4 TIP: Place a shim under rug to allow a finger hold when assembled unit is ready to upright. CONDUIT SNAP-CLIP 6 MALE CONNECTOR FEMALE CONNECTOR 5 GANGING HARDWARE Page 5 of 6

Male end of Modular Table Power Cable Female end of Base Power Infeed Cable Installing 0 Amp Plug Infeed (continued) 7. Connect power infeed to modular cable. - Match like colors only. (Green-to-Green, Red-to-Red, Black-to-Black and White-to-White). Push connectors together until both latches engage. 8. Relocate conduit clamp. Mark mounting hole location. - Do not allow more than 1" of cable between modular connector and clamp.. Wrap first cushioned clamp around Base Power Infeed conduit between shrink-wrapped ground wire and ID label. Wrap second clamp approximately 1/4" from first, but with mounting hole location on opposite side of the conduit. Mark mounting hole locations. - Ensure both cushioned conduit clamps are positioned per artwork shown. 10. Drill pilot holes for clamps.157" diameter by.50" deep, then fasten clamps. Table Run Note: Latches fully engaged. 7 Note: Orient colors on both connectors to match. Note: Cable inside bend radius must not be less than 1.50". Building Power Supply 11. Carefully flip tables upright into use position, and make ganging connection(s). 1. Plug cord into 0 Amp electrical outlet. CONDUIT CLAMP 8 10 CONNECTION TO 7 ID LABEL CUSHIONED CLAMPS 10.5" SHRINK-WRAPPED GROUND WIRE Page 6 of 6