Technical Information Cleanfit Control CYC25

Similar documents
Technical Information Liquiline System CAT810

Technical Information Cleanfit CPA871

Technical Information Cleanfit CPA451

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Technical Information Cleanfit CPA472D

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Operating Instructions CYR52

Technical Information Cleanfit CPA875

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Technical Information Ceraliquid CPS41D and CPS41

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Orbipore CPS91 and CPS91D

Flowfit CYA251. Technical Information. Flow assembly for nitrate/sac, turbidity and oxygen sensors

Orbisint CPS12/CPS12D/CPS13

Ceraliquid CPS42/CPS42D/CPS43

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

Pneumatic control unit for decentralized automation of ELEMENT process valves

Operating Instructions Cleanfit CPA871

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

SITRANS P measuring instruments for pressure

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Angle-Seat Valve System for on/off control. Type 8801/2100 electro-pneumatically operated angle-seat valve + = TWO YEAR WARRANTY on this valve system

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant

Soliswitch FTE20. Technical Information. Point level switch for granular solids

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

DC/DC converters - MINI-PS DC/ 5-15DC/

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Lexium integrated drives

SAX Electronic Valve Actuator

Globe Valve System for continuous control. Type 8802/2301 electro-pneumatically operated globe valve + = TWO YEAR WARRANTY on this valve system

Electric actuators type EA25-250

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Orbisint CPS11 and CPS11D

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Technical specification

Lexium integrated drives

Pressure chlorine changeover unit C 7520

User Manual. Solar Charge Controller 3KW

Mounting and Operating Instructions EB 5868/5869 EN

AirLINE and AirLINE Quick electrical/pneumatic Automation System

Industrial Power Supplies

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Intelligent Lift Control Valve with Electronic Card

OPTISWITCH 6500 C Technical Datasheet

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

OPTISWITCH 6500 C Technical Datasheet

Technical Information Omnigrad TST90, TET90

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Operating Instructions Dipfit CPA111

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Actuators for air dampers and control valves of oil burners

User Manual Solar Charge Controller 3KW

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

BETA Switching Switches and Light Indicators

Positive displacement batch controller

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

SG-B1 SERIES / SG-A1 SERIES

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Recommendations Multipin connector Wired mode (permanent and pulse signal) Positioning mode

ph-kompaktelektrodensystem sensopac CPA 320

Pressure Transmitter JUMO dtrans p30 Type

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Conductivity Measurement CLM 280

Insertion magnetic inductive flowmeter

Operating Instructions Cleanfit CPA875

Technical Documentation

CAUTION CM-SE CM-S21 CM-S41

Unifit CPA442. Technical Information. Process assembly For installation of 120 mm sensors in food and beverage, biotechnology and chemical industries

Digital Pressure Regulator Sentronic PLUS Series 614

Sentronic PLUS 614 Series

Angle seat valve with diaphragm actuator VZXA-...-M

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

Continuous level measuring system NB 3000 Selection list. Overview

Technical Datasheet P-30/P-31. Standard transmitter.

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Operating Instructions Flexdip CYA112

System Manual 02/2008

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Actuators for air dampers and control valves of oil burners

Servo-operated 2/2-way solenoid valves Type EV220A

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

EPS/ELA-Series User Manual EPS/ELA 250W

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Redundant Control System

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

CHEMTROL 460 Control unit Technical information

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide

General Specifications

Ball valve C 200 PROP / C 200 DOS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Transcription:

TI01231C/07/EN/04.16 71326840 Products Solutions Services Technical Information Cleanfit Control CYC25 Cleaning unit for retractable assemblies in conjunction with Chemoclean Plus Application Cleanfit Control allows automatic cleaning of sensors installed in retractable assemblies. This means that sensor performance can be maintained at a high level without any interruption to the process. Cleanfit Control is excellently suited to the following sectors: Water and wastewater Paper Food and beverages Solids / Primaries Power stations Utilities Your benefits Easy setup of automatic cleaning system with low maintenance Easy actuator control and operation Manual control and interruption possible at all times Possible to connect both electrical and pneumatic cleaning and pump units

Function and system design Function A combination of the Liquiline CM44x, the software package Chemoclean Plus and the Cleanfit Control CYC25 allows reliable cleaning of sensors installed in pneumatically controlled retractable assemblies. Alternatively, interval measurement is also possible, i.e. the controlled sensor can be placed in the medium to be measured for short periods of time and, for the remainder of the time, be safely stowed away or regenerated in the service chamber of the assembly. Liquiline CM44x allows a maximum of 2 Cleanfit Control systems to be connected. These are controlled independently of each other. The cleaning sequence is programmed exclusively on the Liquiline CM44x. Two cleaning programs are available. The programs can be controlled as follows: in the form of an interval control system with fixed time intervals in the context of a defined weekly or daily program with up to 6 start times per day as a single event directly on site via a digital input or a bus signal Safety-oriented events can be incorporated into the cleaning program sequence via the digital inputs. For example, the position of the retractable assembly's limit position switches can be incorporated as a precondition for the next step in the cleaning process. If the correct position is not reached within the specified time, the cleaning program is canceled and the system enters "failsafe" mode. It is the function of the Cleanfit Control CYC25 to integrate the actuators into the cleaning program in a safety-oriented manner. That is why the actuators, i.e. assembly, valves and pumps, are not connected directly via the relays to the Liquiline CM44x. Instead they are connected to the Cleanfit Control CYC25. The 24V DC power supply to these actuators, as well as the compressed air supply, are provided by the customer. Every automated system requires a safety shutdown system. In the Cleanfit Control, this is achieved by switching from automatic to manual mode. This switch is also used for the purpose of sensor maintenance. The effect of the switch is that the actuators (excluding the retractable assembly) can no longer activated either electrically or pneumatically. However, the cleaning program as such is not interrupted. In this way, the second switch can be used to move the assembly from measuring mode to service mode and vice versa. Any cleaning media that are connected will not be released until you have switched back to automatic mode. The advantage of this procedure is that the cleaning program does not need to be restarted separately after switching back to automatic mode. Measuring system A complete measuring system comprises: Cleanfit Control CYC25 with at least 1 pneumatic pilot valve to control the assembly, optionally 2 pneumatic pilot valves Liquiline CM44x (incl. sensor) with at least 4 relays and Chemoclean Plus (optionally 4 digital inputs) Pneumatically controlled retractable assembly, optionally with limit switches, e.g. Cleanfit CPA875 or CPA871 1 pneumatically controlled valve or pump for transporting medium and also max. 2 electrically controlled valves (24V DC) or max. 3 electrically controlled valves for cleaning agents Optional multi-inlet (rinsing block) to assembly 2 EndressHauser

1 2 4 6 1 Measuring system 1 Transmitter Liquiline CM44x 2 Cleanfit Control CYC25 4 Pneumatic retractable assembly 6 Cleaning injector Chemoclean CYR10 A0029164 Cleanfit Control is the hardware used to control the actuators such as the assembly, as well as valves and pumps. 1 or 2 pilot valves to control the assembly and other pneumatic actuators (e.g. pumps) Connection possibility for 2 or 3 electrically controlled actuators (e.g. valves) Switch from automatic to manual mode as a safety stop In manual mode, the programming for automatic mode remains in place, and it is not possible to activate any actuators, apart from the assembly. Manual movement of assembly using switch Chemoclean Plus is a function of the Liquiline CM44x for sequential, cyclical control of relays to enable automated cleaning. Time-independent control of up to 4 relays. The program sequence always ends with the initial situation (e.g. assembly is in the same position as at the start). Individual program start via local operation, digital I/O or fieldbus Interval program, weekly program Integration of digital I/O, e.g. limit position switches, to monitor the assembly function Customer-specific "failsafe" program in the event of program interruption or error Liquiline CM44x is a multichannel transmitter for connecting digital sensors with Memosens technology Power supply 100 to 230 V AC, 24 V AC/DC Universally upgradeable SD card slot Up to 4 relays IP 66, IP 67, NEMA 4X EndressHauser 3

Configuration options 1 2 3 4 13 12 11 10 9 8 7 6 5 2 Cleanfit Control with cleaning injector A0024784 Item Description Order code / accessories 1 Transmitter Liquiline CM44x CM442-AA**F4****H7* 2 Cleanfit Control CYC25 CYC25-AAPA 3 Control lines for compressed air To be provided by the customer (OD = 4 mm, ID = 2 mm) 4 Pneumatic retractable assembly For example: CPA875 or CPA871 5 Hose for cleaning agent To be provided by the customer (OD = 16 mm) 6 Cleaning injector Chemoclean CYR10 CYR10-A8 7 Inlet for cleaning agent Hose connection nipple DN12 8 Inlet for motive water Hose connection nipple DN16 9 24 V - supply for valves Connecting cables must be provided by the customer 10 24 V - supply for Cleanfit Control Power supply must be provided by the customer 11 Compressed air supply for Cleanfit Control Compressed air hose (OD = 6 mm, ID = 4 mm ) must be provided by the customer 12 Signal line, transmitter - Cleanfit Control Supplied with CYC25 13 Power supply for transmitter Power supply must be provided by the customer No digital inputs are provided in this configuration. 4 EndressHauser

1 2 3 14 4 13 12 11 10 9 8 7 6 5 3 Cleanfit Control with cleaning injector and limit position detection A0026529 Item Description Order code / accessories 1 Transmitter Liquiline CM44x CM444-AA***FK*****EF* 2 Cleanfit Control CYC25 CYC25-AANAPA 3 Control lines for compressed air To be provided by the customer (OD = 4 mm, ID = 2 mm) 4 Pneumatic retractable assembly For example: CPA875-*F* or CPA871-*F* 5 Hose for cleaning agent To be provided by the customer (DN16) 6 Cleaning injector Chemoclean CYR10 CYR10-A8 7 Inlet for cleaning agent Hose connection nipple DN12 8 Inlet for motive water Hose connection nipple DN16 9 24 V - supply for valves Connecting cables must be provided by the customer 10 24 V - supply for Cleanfit Control Power supply must be provided by the customer 11 Compressed air supply for Cleanfit Control 12 Signal line, transmitter - Cleanfit Control Compressed air hose (OD = 6 mm, ID = 4 mm) must be provided by the customer Supplied with CYC25 13 Power supply for transmitter Power supply must be provided by the customer 14 Cable for electrical limit position detection For example: CPA875-**RA/RB* or CPA871-**RA/RB* EndressHauser 5

1 2 3 14 4 13 12 11 10 16 15 5 4 Cleanfit Control with pump and limit position detection A0026532 Item Description Order code / accessories 1 Transmitter Liquiline CM44x CM444-AA***FK* 2 Cleanfit Control CYC25 CYC25-ABNA 3 Control lines for compressed air To be provided by the customer (OD = 4 mm, ID = 2 mm) 4 Pneumatic retractable assembly For example: CPA875-*F* or CPA871-*F* 5 Hose for cleaning agent To be provided by the customer (DN16) 10 24 V - supply for Cleanfit Control Power supply must be provided by the customer 11 Compressed air supply for Cleanfit Control Compressed air hose (OD = 6 mm, ID = 4 mm) must be provided by the customer 12 Signal line, transmitter - Cleanfit Control Supplied with CYC25 13 Power supply for transmitter Power supply must be provided by the customer 14 Cable for electrical limit position detection 15 Canister for cleaning agent with pneumatically operated pump For example: CPA875-**RA/RB* or CPA871-**RA/RB* Canister with double diaphragm pump 16 Pneumatic control line To be provided by the customer 6 EndressHauser

1 2 3 14 4 13 12 11 10 16 18 5 5 Cleanfit Control with pneumatic valve and limit position detection A0026534 Item Description Order code / accessories 1 Transmitter Liquiline CM44x CM444-AA***FK* 2 Cleanfit Control CYC25 CYC25-ABNA 3 Control lines for compressed air To be provided by the customer (OD = 4 mm, ID = 2 mm) 4 Pneumatic retractable assembly For example: CPA875-*F* or CPA871-*F* 5 Hose for cleaning agent To be provided by the customer (DN16) 10 24 V - supply for Cleanfit Control Power supply must be provided by the customer 11 Compressed air supply for Cleanfit Control 12 Signal line, transmitter - Cleanfit Control Compressed air hose (OD = 6 mm, ID = 4 mm) must be provided by the customer Supplied with CYC25 13 Power supply for transmitter Power supply must be provided by the customer 14 Cable for electrical limit position detection For example: CPA875-**RA/RB* or CPA871-**RA/RB* 16 Pneumatic control line To be provided by the customer 18 Pneumatic valve TSP 71181130 EndressHauser 7

1 2 3 14 4 13 12 11 10 16 9 18 5 17 6 Cleanfit Control with electrical and pneumatic valve and limit position detection A0026533 Item Description Order code / accessories 1 Transmitter Liquiline CM44x CM444-AA***FK*****EF* 2 Cleanfit Control CYC25 CYC25-ABNA 3 Control lines for compressed air To be provided by the customer (OD = 4 mm, ID = 2 mm) 4 Pneumatic retractable assembly For example: CPA875-*F* or CPA871-*F* 5 Y - connector To be provided by the customer 9 24 V - supply for valves Connecting cables must be provided by the customer 10 24 V - supply for Cleanfit Control Power supply must be provided by the customer 11 Compressed air supply for Cleanfit Control 12 Signal line, transmitter - Cleanfit Control Compressed air hose (OD = 6 mm, ID = 4 mm) must be provided by the customer Supplied with CYC25 13 Power supply for transmitter Power supply must be provided by the customer 14 Cable for electrical limit position detection For example: CPA875-**RA/RB* or CPA871-**RA/RB* 16 Pneumatic control line To be provided by the customer 17 Electrical valve To be provided by the customer 18 Pneumatic valve TSP 71181130 8 EndressHauser

4 3 19 5 6 7 8 9 7 Cabinet with Cleanfit Control and Liquiline CM44x transmitter A0026745 Item Description Order code / accessories 3 Control lines for compressed air To be provided by the customer (OD = 4 mm, ID = 2 mm) 4 Assembly Cleanfit CPA875 Individually selectable 5 Hose for cleaning agent To be provided by the customer (DN16) 6 Cleaning injector Chemoclean CYR10 CYR10-A8 7 Inlet for cleaning agent Hose connection nipple DN12 8 Inlet for motive water Hose connection nipple DN16 9 24 V - supply for valves Connecting cables must be provided by the customer 19 Cabinet for Liquiline CM44x and Cleanfit Control CYC25 Installation housing (accessory) EndressHauser 9

Power supply Wiring diagram - fuse: 2,5A T 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 - - - - - power connection (24VDC) CM44x CYR10 CPAx7x power connection (24VDC) feedback assembly DI12 (92) valve cleaner/ water limit position switch (service) limit position switch (service) limit position switch (measure) limit position switch (measure) feedback assembly (service) DI1 (91) feedback assembly (measure) DI2 (91) relay 1 (42) relay 34 (41) relay 12 (41) relay 4 (42) valve cleaner, relay 3 (42) valve water, relay 2 (42) 8 Wiring diagram A0026182 The terminals on the gray background are intended for internal wiring. Supply voltage Power consumption Circuit breaker Fuse The power supply for the CYC25 unit must be provided by the customer and meet the following requirements: Separate power supply 24 VDC ±10 % The power supply must be limited to a maximum of 70 VDC in the event of an error. Conductor cross-section: 0.5 mm 2 min. Max. 40 W NOTICE The device does not have a power switch The customer must provide a protected circuit breaker in the vicinity of the device. The circuit breaker must be a switch or power switch, and you must label it as the circuit breaker for the device. At the supply point, the power supply must be isolated from dangerous live cables by double or reinforced insulation in the case of devices with a 24 V supply voltage. Fine-wire fuse, slow-blow 250 V/2.5 A 10 EndressHauser

Electrically controlled actuators/valves Example of wiring 24 V DC, max. 8 W per actuator/valve Example of wiring with CPA87x and CYR10 CYC25 A CM44x 14 1 41 relay 1 12 2 42 relay 1 13 3 41 relay 3 13 14 15 4 5 6 41 41 42 relay 4 relay 2 relay 4 2 7 92 DI 1 2 8 92 DI 2 10 9 91 DI 1 11 10 91 DI 2 16 11 42 relay 3 17 12 42 relay 2 3 24 VDC 0 1 6 C service 7 service 8 measure 9 measure B B cleaner cleaner water water CYR10 CPA87x 9 Example of wiring A Connecting cable CM44x to CYC25 (included in scope of delivery with CYC25) B Connecting cable CYR10 to CYC25 (to be provided by customer, 0.5 mm 2, max. length: 30 m (98 ft)) C Connecting cable CPA87x to CYC25 (can be ordered via CPA87x, max. length: 30 m (98 ft)) A0027097 If you use connecting cables other than those supplied, please ensure they have a minimum cross-section of 0.5 mm 2 EndressHauser 11

Installation Pneumatic connections Prerequisites: Air pressure of 4 to 6 bar (58 to 87 psi) Compressed air quality in accordance with ISO 8573-1:2001 Quality class 3.3.3 or 3.4.3 Solids class 3 (max. 5 μm, max. 5 mg/m3, contamination with particles) Water content for temperatures 15 C: class 4 pressure condensation point 3 C or lower Water content for temperatures of 5 to 15 C: class 3 pressure condensation point -20 C or lower Oil content class 3 (max. 1 mg/m 3 ) Air temperature: 5 C or higher no continuous air consumption Minimum nominal diameter of air pipes: 2 mm (0.08 ") Damage to seals due to excessive air pressure! If the air pressure can increase to more than 6 bar (87 psi) (even short pressure surges), a pressurereducing valve must be installed upstream. Maximum cable length Cable between Maximum cable length CYC25 and assembly CYC25 and CYR10 30 m (98 ft) 30 m (98 ft) Environment Ambient temperature range Storage temperature Humidity Degree of protection Electromagnetic compatibility Electrical safety -10 to 45 C (10 to 113 F) -40 to 80 C (-40 to 175 F) 10 to 95%, not condensing IP64 Interference emission and interference immunity as per EN 61326-1:2006, class A for industrial sectors IEC 61010-1, protection class III (electrical safety due to safety extra low voltage) Low voltage: overvoltage category II Environment < 2000 m (< 6562 ft) above MSL 12 EndressHauser

Mechanical construction Dimensions A H C 5 D 6 E 7 8 F I G 162 (6.38) 1 2 3 4 B 199 (9.33) Ø9 (0.35) 128 (5.04) 194 (7.64) 237 (9.33) 10 Dimensions in mm (inch) A0028630 Cable glands Qualified cable glands Cable gland Clamping area, permitted cable diameter M16 x 1.5 mm 3 to 6 mm (0.12 to 0.24") M20 x 1.5 mm 6 to 12 mm (0.20 to 0.35") EndressHauser 13

Electrical and pneumatic connections H 5 6 7 8 I X A C D E F G 1 2 3 4 B 11 Cable entries and nematic connections A Cable entry (optional) B Compressed air supply AD 6 mm (supplied by customer) C Cable entry CYR10 water D Cable entry signal line CM44x H Cable entry CYR10 cleaning agent 2 Compressed air outlet AD 4 mm (optional) 3 Compressed air outlet, assembly moves to measuring position AD 4 mm 4 Compressed air outlet, assembly moves to service position AD 4 mm 5 Cable entry power supply 24 V X Housing vent (connection remains open) A0026090 Materials Housing material Bottom part of housing Cover Housing seal PC-FR PC-FR EPDM Weight 2.44 kg (5.38 lbs) Operability Operating elements 1 2 AUTO 12 Operating elements 1 Manual control for moving the assembly 2 Changeover switch for automatic mode/manual mode A0028922 14 EndressHauser

Operating concept In automatic mode, the cleaning sequence is controlled exclusively by transmitter CM44x. Certificates and approvals mark The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EC directives. The manufacturer confirms successful testing of the product by affixing to it the mark. Ordering information Product page Product Configurator www.endress.com/cyc25 On the product page there is a "Configuration" button to the right of the product image. 1. Click this button. The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right above the selection window. For many products you also have the option of downloading CAD or 2D drawings of the selected product version. To do so, click the "CAD" tab and select the desired file type using dropdown lists. Scope of delivery The scope of delivery comprises: 1 CYC25 in the version ordered 1 Operating Instructions 1 Mounting plate 1 Connecting cable CM44x to CYC25 EndressHauser 15

Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Canister with double diaphragm pump Canister 5 l (1.32 US gal), material: PE Double diaphragm pump, material: PP Order No. 71029969 Hose connection set G¼, DN 12 PVDF (2 x) Order No. 50090491 Hose connection set G¼, DN 12 1.4404 (AISI 316L) 2 x Order No. 51502808 Hose connection set G¼, DN 16 PVDF (2 x) Order No. 51511591 Hose connection set G¼, DN 16 1.4404 (AISI 316L) 2 x Order No. 51511590 Compressed air tube 6 mm AD, length: 10 m (approx. 33 ft.) Material: PE Order No. 71114631 Pneumatic rinsing valve Material on inlet side: PVDF Power supply for air: 5 to 7 bar (73 to 100 psi) Order no. TSP 71181130 Installation housing For the installation of CM44x and CYC25 (both not included) with viewing window Mounting plate with threaded holes for installing the device at the customer site 8 cable entries in left side panel Material: GFR or 1.4301 (AISI 304) Dimensions: height x width x depth: 648 mm x 436 mm x 250 mm (25.5" x 17.2" x 9.84") Order no. TSP 71286806 (GFR version) Order no. TSP 71286807 (SS 304 version) 13 Installation housing A0026706 16 EndressHauser

Post mounting kit For securing the field housing to horizontal and vertical posts and pipes Material: stainless steel 1.4301 (AISI 304) Order No. 50086842 90 (3.54) 70 (2.76) Ø 8 (0.31) 30 (1.18) Ø max. 60 (2.36) Ø 8 (0.31) 70 (2.76) 90 (3.54) 60 (2.36) M6 70 (2.76) 90 (3.54) Ø 6 (0.24) 14 Dimensions in mm (inch) CYY101 Weather protection cover for field devices Absolutely essential for field installation Material: stainless steel 1.4301 (AISI 304) Order No. CYY101-A A0024660 EndressHauser 17

www.addresses.endress.com