Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Similar documents
Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Table of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod

Installation Instructions

Cable-Operated Disconnect Switches. Accessories

PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Kits for 125A, 150A 250A and 400A Frame Sizes

Installation Instructions for Replacement Mechanism Kit

Bulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts

Bulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)

OPERATOR ADAPTER A21ABA

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Flange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

USER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure

600V, Non-Fusible, (3-Pole, 3 Phase)

Patriot. Aluminum and Steel 5spring. Step #1 Tarp Spool with Gear Motor (Includes Instructions for Optional Wind Deflector)

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

CCP2-FLR1-21_ flange-rod operating mechanism

Isolation Switch (behind barrier & inspection window) Power Fuses. Load Cable Connection Box. Contactor. Control Power Transformer Secondary Fuse

PLEASE READ THESE INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

GE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Installation Guide

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

EXTERNAL DISCONNECT ENCLOSURE INSTALL

Installation Instructions

COOKSON OWNER'S MANUAL

Installation Instructions

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

WARNING! THIS PRODUCT MUST BE INSTALLED BY A TRAINED, AUTHORIZED RICON SERVICE TECHNICIAN.

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

ENCLOSURES & PANELS. The Trusted Source for Innovative Control Solutions

KT101 Series Governor System Installation Kit Cummins 4B(T) / 6B(T) With CAV/DPA Pump

Installation Instructions

Haul-Your-Might T3. Product Name: Product Code: Please read all instructions carefully before assembly, installation and/or use of this product.

OPERATOR ADAPTER ABF

Publication: PDI-010 Date: March 5, 2010 Model: UXV 500

SEQUESTR. External Disconnect Enclosure. Rev. A 2014 Pentair Equipment Protection PH hoffmanonline.com P/N

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

DODGE SuperRail Mounting Kit #0848

Installation Instructions

Universal Super Shield & Ultimate Aluminum w/electric Drive Conversion Kits , , Installation Instructions

Installation Instructions

ibusway for Data Center

REV READ BEFORE INSTALLATION OF KIT:

w w w. h d o n l i n e s h o p. d e ROAD TECH QUEST GLOBAL POSITIONING SYSTEM (GPS) MOUNTING KIT GENERAL INSTALLATION -J03554 REV.

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Preferred Cutout, Disconnect Enclosure, Type 12

Operation and Maintenance Manual

Instruction Bulletin. Jockey Pump Controller

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

2-row and All-row systems included.

Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Disconnect Enclosures

Installation Instructions For Motor Control Center (MCC) Units

Instruction Sheet Kit Number:

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

Rear Door: Service and Repair REAR DOOR

Draper Platform Adaptation Bundle

ch2200 ch2300 mt3 osprey pro-trim single s twin s sl-3 INSTALLATION INSTRUCTIONS AND OWNERS MANUAL

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

Detroit Speed, Inc. Rear QUADRAlink Conversion Kit Camaro/Firebird P/N:

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

OPERATOR ADAPTER ABBSV

CENTERLINE 2100 Motor Control Centers 600A, 800A, and 1200A Bolted Pressure Contact Switch

460 HORIZON DR. SUITE 100 SUWANEE, GA PHONE: FAX: Renegade 3 Sidebar.

Parkit360 Transformer

SELF DRILL SCREWS FILLER STRIP

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Ford Super Duty Recoil Traction Bar System. Part#: ,123409

C-10 INSTALLATION INSTRUCTIONS

INSTALLATION & OWNER S MANUAL

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

KT230 Series Caterpillar 3406 Governor System Installation Kit

R24. Instruction manual

Universal Mounting Kit #0820

M-5220-MB Mustang GT Side Exhaust Kit INSTALLATION INSTRUCTIONS

2010+ Victory Cross Country / Cross Roads Installation Guide Nov 2014

It don t mean a thing If it ain t got the swing

Installation Instructions

WOC-364 Installation Instructions Ranger XP Heater System

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Sentinel Field Satellite Controller

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

INSTALLATION INSTRUCTIONS AM rev. A

Transcription:

Bulletin 494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 494C- _ Series : 600A) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants. ATTENTION: The following procedures are critical to the proper operation of the disconnect handle and switch. Failure to follow these steps can result in damage to the equipment and/or serious injury or death to the operator. Table of Contents Page Quick Installation Guide - Disconnect Switch Installation,3 - Disconnect Handle Installation 3 - Cable Mechanism Installation 4 - Connecting Rod Adjustment Procedure 5 Conversion from Right Hand to Left Hand Operation 6 Enclosure Without Handle Cutout 7 - Locate Handle - Drill Handle Holes Door Catch Mounting Bracket Installation 8 Trailer Fuse Block Installation (600A) 9 Fuse Clip Installation (600A) 0 Bulletin 494C Cable Operated Disconnect Switch Kit Components Bulletin 494C Cable Operated Disconnect Switch Kit Optional Accessory List 405-90-0 () Printed in U.S.A.

QUICK INSTALLATION GUIDE IMPORTANT: When locating the 600A switch, verify that the minimum diameter for the loop of the cable between the switch mechanism and handle mechanism is not less than 6 inches. Any reduction to the diameter of the bend loop for the cable will reduce the efficiency of the cable system, and create additional drag and friction within the cable conduit. IMPORTANT: Verify that the cable assembly does not interfere with any mechanical and moving parts. Keep the cable conduit a minimum of /" from all heat sources and current carrying terminals, fuses, transformers, etc. Disconnect Switch Installation a Locate switch with right hand mechanism 8-/4" 5" 8-/4" 5" (4) - 9/3" Dia. Mounting Holes (4) - 9/3" Dia. Mounting Holes 6" Dia. Minimum Enclosure with Right Hand Flange 6" Dia. Minimum Enclosure with Left Hand Flange b Locate switch with left hand mechanism 5" 8-/4" 5" 8-/4" (4) - 9/3" Dia. Mounting Holes (4) - 9/3" Dia. Mounting Holes 6" Dia. Minimum 6" Dia. Minimum Enclosure with Right Hand Flange Enclosure with Left Hand Flange ()

Disconnect Switch Installation (Cont'd) Rotate crossbar to closed position. 3 Assemble the cable mechanism bracket to the disconnect switch. 90-30 lb-in 4 Turn the connecting rod clockwise (approximately 9-0 5 turns) until jam nuts touch drive bar Turn the connecting rod counter-clockwise (less than turn) until hole in threaded rod aligns with hole in cable mechanism lever. Drive Bar Threaded Rod Jam Nuts Cable Mechanism Lever (3)

Disconnect Switch Installation (Cont'd) 6 Attach threaded rod to cable mechanism lever. 7 Assemble disconnect switch assembly to mounting plate. Threaded Rod 90-30 lb-in 90-30 lb-in 90-30 lb-in Cable Mechanism Lever (4) - 5/6-8 thread forming screws provided with disconnect switch. Disconnect Handle Installation Install gasket. Install handle and mechanism bracket. 3 Install defeater lever. 60-80 lb-in (Right Hand Flange Mounted Shown) 7- lb-in NOTE: Apply grease from capsule to gasket or groove to retain gasket to handle. 3 Cable Mechanism Installation Verify that disconnect switch and handle are in the "ON" position. Rotate connecting rod (clockwise) into drive bar until it begins to exit the drive bar (approximately 8 full turns). C L O S E D (4)

3 Cable Mechanism Installation (Cont'd) 3 Align connecting rod with primary link. 4 Install hitch pin clip Hitch Pin Clip Connecting Rod Primary Link 5 Turn disconnect handle "OFF" and install handle mechanism spring. 4 Connecting Rod Adjustment Procedure "ON" Position ➊ Move disconnect handle to the "ON" position. ➋ If switch does not fully close, return handle to "OFF" position. ➌ Remove link spring hitch pin and disengage the connecting rod from the primary link. ➍ Turn connecting rod counter-clockwise ( or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring. "OFF" Position ➊ Move disconnect handle to the "OFF" position. If switch does not fully open, return handle to "ON" position. ➋ ➌ Remove hitch pin and link spring, then disengage the connecting rod from the primary link. ➍ Turn connecting rod clockwise ( or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test. ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring. ATTENTION: CHECK FOR PROPER OPERATION. Upon completion of the installation instructions, no further adjustment of the cable mechanism is required. (5)

Conversion from Right Hand to Left Hand Operation (If Required) IMPORTANT: Switch conversion to left-hand operation requires left-hand cable mechanism. Remove drive mechanism from right side of switch (3) - 5/6-8 Hex Head Screws with disconnect switch in the "OFF" position. Rotate crossbar to closed position. 3 Reinstall drive mechanism on left side of switch ATTENTION: With switch in the "CLOSED" position, drive mechanism should align with crossbar. 90-30 lb-in (6)

Enclosure without Handle Cutout Enclosures with a Flange Thickness less than 3/6" use dimensions below to install disconnect handle. Locate Handle -/8" -/8" -3/8" -3/8" 8-3/6" 8-3/6" Top Handle Hole Right Hand Flange Left Hand Flange Drill Handle Holes ().38 Dia. Holes Top Handle Hole 5/6" /" /4" 5-/" 6-/" Square corners or up to /4" radius (7)

Door Catch Bracket Installation Right hand installation shown (for left hand installation follow similar procedures) Door Catch Mounting Bracket: Provided with projections for welding. Projections can also be used as a guide for drilling holes. Can be used as a template to drill corresponding holes in the enclosure door. User to supply the hardware for fastening the bracket. Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. The bracket hardware must be inaccessible to unauthorized personnel. Dimension K (3/4" to ") When using large disconnect handle kit only (494F-M or -S), use door catch provided with handle kit. When using large disconnect handle kit and small door hardware kits (494V-L, -LL, -L or -LL), use door catch provided with door hardware kit. Dimension K (-/8" to -3/8") When using large disconnect handle kit and large door hardware kits (494V-L3 or -LL3), use door catch provided with door hardware kit. Door Catch Mounting Bracket Top TOP VIEW Door Catch Enclosure Door Door Catch Mounting Bracket Flange Thickness K Door Catch - /8" - 5/8" - 3/8" Enclosure Base -/8" -/8" -3/8" -3/8" 8-3/6" 8-3/6" 3-3/4" 3-3/4" Top Handle Hole Door Catch Mounting Bracket -5/8" -5/8" Door Catch Mounting Bracket Right Hand Flange (8) Left Hand Flange

Trailer Fuse Block Installation (Switch Rating 600A) Note: Not required for non-fusible disconnect switch applications. Trailer Fuse Block Location (400A Class H, J, R Fuses) Trailer Fuse Block Location (600A Class J Fuses) 8-/4" 8-/4" 6-3/4" 6-3/4" A 3/6" 3-3/6" A 3/8" 3" 3-5/6" 3-5/6" -3/6" 3" Note: Terminal bolts need to be moved from disconnect switch load terminals to fuse block. -3/6" 3" 6-3/4" 6-3/4" Amps Voltage Class Fuse Clip 400 400 400 400 Amp Trailer Fuse Block (494V-FSV400) Fuse Torque (lb-in) A Fuse Lug to Block Terminal 50 600 600 H/R H/R J -3/4" 4-/4" -/8" Wire into Lug -37 90-30 75-00 75-305 Fuse 600 Amp Trailer Fuse Block (494V-FS600) Torque (lb-in) A Fuse Lug to Block Terminal Amps Voltage Class Fuse Bolt Wire into Lug 600 50 / 600 J 4-3/8" 300-350 90-30 75-00 75-305 3 Trailer Fuse Block Location (600A - 50V / 600V Class H, R Fuses) Note: Refer to instructions provided with separately mounted fuse blocks (Catalog Numbers 49-N6 and 49-R6). (9)

Fuse Clip Installation (Switch Rating 600A) 400A Fuses (Class H, J, R) 600A Fuses (Class J) 300-350 lb-in 40-55 lb-in 300-350 lb-in 4 3 600A Fuses (Class H, R) Note: Refer to instructions provided with separately mounted fuse blocks (Catalog Numbers 49-N6 and 49-R6). (0)

Bulletin 494C Cable Operated Disconnect Switch Kit Components Disconnect Switch Kit Cat No. Switch with Right Hand Mechanism 494V-DS600 (600A) Convertible in the field for Left Hand operation Switch Handle 494F-M (7-/" Painted Metal) (400A / 600A) 494F-S (7-/" Stainless Steel) (400A / 600A) Cable Mechanism Cable with Right Hand Mechanism 494C-CM3: 600A (4 Ft Cable) 494C-CM4: 600A (5 Ft Cable) 494C-CM5: 600A (6 Ft Cable) 494C-CM6: 600A (0 Ft Cable) Cable with Left Hand Mechanism 494C-CMX3: 600A (4 Ft Cable) 494C-CMX4: 600A (5 Ft Cable) 494C-CMX5: 600A (6 Ft Cable) 494C-CMX6: 600A (0 Ft Cable) Mounted with Switch 494V-FSV400 (400A Class H, J, R) 494V-FS600 (600A Class J) Fuse Block Separately Mounted 49-N6 (600A 50V / 600V Class H) 49-R6 (600A 50V / 600V Class R) 400A Fuses 40-N46 (Class H, J, 400A-50V, 400A-600V) 40-N55 (Class R, 400A-50V, 400A-600V) Fuse Clips 600A Fuses Class J - Bolts directly to switch and fuse block (no clips required) Class H, R - Fuse clips included with separately mounted fuse blocks Cat. Nos.49-N6 and 49-R6 ()

Bulletin 494C Cable Operated Disconnect Switch Kit Optional Accessory List Optional Accessories (Installation Instructions Included with Accessory Kits) Catalog Number and Description Electrical Interlock Switch with Right Hand Mechanism 495-N34 (-N.O./N.C.) * 495-N35 (-N.O./N.C.) * *Requires Adapter Kit 495-N36 Auxiliary Contact 595-A (-N.O.) (600A) * 595-B (-N.C.) (600A) * *Requires Adapter Kit 595-N Switch and Fuse Block 494R-N0 (CU Wire () - #/0-350 MCM) (600A or 400A Fuse Block) (3 per kit) Lug Connectors 494R-N (CU Wire () - #/0-500 MCM) (600A or 400A Fuse Block) (3 per kit) Separately Mounted Fuse Blocks 494R-N (CU Wire () - #/0-350 MCM) (600A) ( per kit) Switch Rating Fuse Class Fuse Clip Rating 50V 600V Cat No. Fuse Cover with Door 600A Non-Fusible ---- ---- 495-N6 600A H, J, R 400A 400A 495-N6 600A J 600A 600A 495-N6 Available only for R.H. mounted disconnect switch. 600A H,R 600A 600A N/A 405-90-0 () Printed in U.S.A.