GE Sensing & Inspection Technologies

Similar documents
User s Guide. Series DPG701. Room Pressure Monitor. omega.com.

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Model 116 DPI Switch Installation and Operating Instructions

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

SR1V. Industrial Low Cost String Pot

Compact Low Pressure Sensor

534HS Pressure Transmitter

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

ATP-2040 Electric Damper Actuator/Transmitter

M9216 Series Electric Spring Return Actuators

POWERLINE 2000 Energy Management System TM

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Carbon Monoxide Transmitter

RESISTIVITY MONITOR/CONTROLLERS

PARKING LOT CONTROLLER WITH LOGIC & MAIN CONTACTOR

Instruction Manual. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Installation and Operation Instructions DLP Series

Model 550 Series Vibration Switches

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation

Induction Power Supplies

T21 Thermal Differential Switch

System 350 P352AB Electronic Pressure Control Series

DC Variable Speed Drive Panel

Signet Pressure Transmitter

Signet Pressure Transmitter

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Installation and Operating Manual

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

1100 Series Piston Type Differential Pressure Gauges

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

D I S S O L V E D O Z O N E M O N I T O R INSTRUCTIONS FOR USE

CAP ANALOG 4100 INSTALLATION & OPERATION MANAUL

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

Figure 1: WPR2 Dimensions and Hardware

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER

Warnings and Cautions. Precision Flow Insertion Mass Flow Meter. Instruction Manual BULLETIN F-41-PFS FR# R

TRAC-3 TENSION READOUT AND CONTROL

DMC mA Positioner

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Fincor Series 2230 MKII/2240

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

Model 930 Power Control System Instruction Manual

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

CABINET REEL OPERATING INSTRUCTIONS

Pressure Transmitter

BAPI-Stat 3 Room Sensor

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Adjustable Torque Controls

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

C3000 SIGNAL TRANSMITTER. Introduction

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

RP-4000 Reserve Power Control

PRODUCT INFORMATION BULLETIN

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

LF Series Spring Return Direct Coupled Actuator

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

SM-1000 SERIES ROTARY ACTUATORS

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Model 124 Filter Minder & Model 124

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

Product Guide: Series III Pump Control Board Set (RoHS)

Electric Actuator Options & Accessories

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

P3 3-STOP POSITIONER IOM

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

STEADYWEB TENSION CONTROLLER Data Sheet

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

CONDUCTIVITY MONITOR/CONTROLLER. Installation Operation Maintenance. User Manual for Models

Municipal Water System Level Control

Guardian Battery Charger Series. Installation and Operations Manual Section 75

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

730 CONTROL SERIES. Instruction Manual CONTROLS. Low Voltage DC Brushless Control. Phone (317) Fax (317)

30A SMART ENERGY MANAGEMENT SYSTEM TM

Transcription:

GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation and Setup Guide 1. GENERAL The RPM-1 monitors either positive or negative room pressures (see the Datasheet for detailed specifications). 2. INSTALLATION The instrument is designed for surface-mounting on a wall with three #10 (5 mm) screws. Select a wall area that is reasonably flat to prevent stressing of the enclosure. A mounting template is included with this document (see insert). 3. WIRING AND PIPING 3.1. Electrical Connections!WARNING! Before applying power to the unit, be sure the 120/240 VAC selector switch is properly set for your power source. Note that there is no selector switch on units configured for 24 VAC operation. Make the following connections at J1, a 3/8 terminal barrier strip with #6 screws (see Figure 1 below): 1. Connect the power supply to terminals 1 and 2. [DO NOT connect the power supply to any other terminals!] 2. Connect an alarm to either of the following Relay Out terminals: a. For normally-open operation - terminals 4 (NO) and 6 (COM). b. For normally-closed operation - terminals 5 (NC) and 6 (COM). 3. Connect the analog output device to either of the following output terminals: Note: a. For a 0-10V output - terminals 8 (COM) and 9 (+). [These are NOT power supply input terminals!] b. For a 0-5V output - terminals 8 (COM) and 10 (+). [These are NOT power supply input terminals!] c. For a 4-20mA, sourcing output - terminals 11 (+) and 12 (-). [These are NOT power supply input terminals!] The voltage analog output signal wires should not exceed 18 ft (6 m). The length of the 4-20 ma analog output signal wires is not limited, but the total loop resistance must be less than 580 Ω.. 4. A 15 V, 13 ma maximum, power supply is available from terminals 8 (COM) and 3 (+). 5. A light indicator status signal is available at terminals 8 (COM) and 7 (+). The output is low (about 1 V) when the pressure is within the normal range (green LED ON). NEVER connect power supply inputs to these terminals 120/240 VAC Selector Switch* *No Selector Switch for 24 VAC units 1 2 3 4 5 6 7 8 9 10 11 12 NO NC COM COM + + + AC Power Supply Input 15V 13mA Supply Relay Out Light Status Signal 0-10V 0-5V Figure 1: Electrical Connections - Terminal Strip J1 4-20mA 1100 Technology Park Drive Billerica, MA 01821 Web: www.gesensing.com March 2008

RPM-1 Room Pressure Monitor March 2008 3.2. Pressure Connections To monitor the differential pressure between a room and a selected reference, connect the air line from the room to be monitored to the fitting labeled ROOM PRESSURE, and the air line from the reference area to the fitting labeled REFERENCE. A positive reading on the digital display indicates that the pressure in the monitored room is higher than the reference pressure, and a negative reading on the digital display indicates that the pressure in the monitored room is lower than the reference pressure. Three sets of barb fittings accommodate plastic tubing sizes from 1/8 to 7/32 I.D. (3 to 6 mm I.D.) IMPORTANT: Do not overtighten the fittings. Hand-tightening 1/4 turn is sufficient to ensure a leak-proof connection. 4. Display Panel To open the clear polycarbonate cover, depress the ridged slot on the narrow side of the bicarbonate cover and pull. The cover can be installed to hinge from the left or from the right. To remove the cover, open the cover and place thumbs along the inside hinge of cover. Carefully push the cover forward (away from the case) while pushing the hinge down. Use the same technique to remove the latch. To install the cover, align the cover to the desired side, left or right, of the body hinge retainers. Insert the centering pins in the cover through the two side retainers on the case and pull up; the cover will snap into place. To install the optional cover lock, remove the blank in the cover lock assembly, insert an optional key and press until the slotted end is flush with cover. 4.1. Panel Description Refer to Figure 2 below to locate the panel components: A B C RELAY LIGHT + STATUS ROOM PRESSURE MONITOR RPM-1 KPASCALS PASCALS INCHES OF WATER TRANSMITTER E F G D AREA I.D. Figure 2: Display Panel Components A- Status selector switch and accompanying indicator lights: The selector switch enables the user to program the red and green lights which indicate when the pressure in the room is above or below a preset pressure. When monitoring a positive pressure, set the selector switch to +. The green LED is ON when the pressure is above the minimum set pressure. The red LED lights up if the pressure falls below the allowed minimum pressure. When monitoring a negative room pressure, set the selector switch to. The green LED is ON when the pressure is below the minimum set pressure. The red LED lights up if the pressure rises above the allowed minimum pressure. B- Light-adjust potentiometer: To change the light set pressure, remove the plug marked LIGHT and turn the potentiometer (clockwise to raise the pressure setpoint) until the desired set pressure is reached. The setting may be determined by pressurizing the instrument until the STATUS indicator light activates. The pressure may be read from the display panel at the moment the light changes status. Refer to section 5.2.2 for a precise calibration procedure. C- Relay-adjust Potentiometer: A SPDT relay output is available at terminals 4, 5, and 6 of connector J1 (see Figure 1 on page 1). The contacts are rated 5 A at 30 VDC or 120 VAC, and 4 A at 240 VAC resistive. To adjust relay set pressure, use the potentiometer located behind the plug marked RELAY. Turn the potentiometer (clockwise to raise the pressure setpoint) until the desired pressure is reached. The relay is set at the factory to energize on falling pressure. To change the logic, see section 5.1.2 and refer to section 5.2.2 for a precise calibration procedure. Page 2

March 2008 RPM-1 Room Pressure Monitor D- Digital Display: The digital display shows the room pressure in either English or metric engineering units. To change the units of measurement, refer to section 5.2.1. E- Unit Indicating Light: One of three lights indicates the unit of measure being displayed. F- Transmitter Span Adjust Potentiometer: Should the pressure transmitter require recalibration, remove the plug to gain access to the potentiometer. It is recommended that the recalibration be performed in the field only if proper calibrating equipment is available. Refer to section 5.3 for calibration instructions. G- Transmitter Zero Adjust Potentiometer: Used during calibration of the instrument. 5. Additional Controls Disconnect the AC power to the instrument, and remove the front panel to gain access to additional controls. Two interconnected PC boards are seen. One board is labeled RPM MAIN BOARD and the other is labeled RPM DISPLAY BOARD. 5.1. Main Board The main board (see Figure 3 below) consists of a power supply, a pressure-sensing element and associated electronics, alarm circuitry and a relay. 5.1.1 - To change the deadband of both the lights and the relay, locate potentiometer R53, labeled DEADBAND, and rotate the screw to the desired position. The deadband adjustment ranges from 0 to 20%. Fluttering indicator lights and a chattering relay output indicate that the deadband is set too low. Increase the deadband until the chatter stops. 5.1.2 - To change the relay logic from energizing on falling pressure to energizing on rising pressure, locate connector J5, remove both jumpers, rotate them 90 and re-insert. R53 (Deadband) J5 (Relay Logic) Figure 3: Main Board 5.2. Display Board 5.2.1 - To change from English to metric unit, locate the selector switch SW2 on the display board (see Figure 4 below) and select either METRIC (Pascals and kpascals) or ENGLISH (inches of water). SW2 (Units) Figure 4: Display Board Page 3

RPM-1 Room Pressure Monitor March 2008 5.2.2 - Apply the AC power to the unit. - To obtain a precise LIGHT adjust or RELAY adjust setting, locate test points GND, T4 and T3 on the display board. - The telescoping voltage range is 0-5.0 volts. - To adjust the light set pressure, connect a voltmeter across GND and T4 and adjust potentiometer R4. - A reading between 2.5 and 5.0 volts will activate the light when the room pressure is higher than the reference pressure. A reading between 0 and 2.5 volts will activate the light when the room pressure is lower than the reference pressure. - To adjust the relay set pressure connect the voltmeter across GND and T3 and adjust potentiometer R3. - A reading between 2.5 and 5.0 volts will energize the relay when the room pressure is higher than the reference pressure. - A reading between 0 and 2.5 volts will activate the relay when the room pressure is lower than the reference pressure. 5.3. Calibration To calibrate the transmitter, proceed as follows: 5.3.1 - Connect a voltmeter across terminals 8 (ground terminal) and 10 (5.00 Volt Output) of connector J1 on the Main Board (refer to Figure 1 on page 1). - Locate the ZERO potentiometer R2 and the SPAN potentiometer R1 on the display board (see Figure 4 on page 3). - With no pressure applied to the pressure ports, adjust the ZERO potentiometer R2 until the output signal between terminals 8 and 10 of J1 is 2.50 volts. - Apply full pressure to the positive pressure port and adjust the SPAN potentiometer R1 until the output signal is 5.00 volts. - Check the zero pressure output again and repeat the above steps if necessary. - When the instrument is fully calibrated. pressurize the reference port. When full pressure is applied to the reference port, the voltmeter should read 0 volts. No adjustment is necessary. 5.3.2 - To check the 10 Volt output, connect the positive side of the voltmeter to terminal 9 (10.00 Volt Output) of connector J1. - The output signal should read 5.00 volts when no pressure is applied and 10.00 volts at full pressure. - No adjustment is necessary if the instrument has been calibrated as specified above. 5.3.3 - To check the current output, first proceed with the calibration steps above, then connect an ammeter across terminals 11 and 12 of connector J1. - Locate the 4-20 ma ZERO ADJUST, R51, and the 4-20 ma SPAN ADJUST, R52 potentiometers on the main board, (see Figure 3 on page 3). - With no pressure applied to the pressure ports, adjust the ZERO potentiometer R51 until the output signal reads 12 ma. - Apply full pressure and adjust the SPAN potentiometer R52 until the output signal is 20 rna. - Check the zero pressure output again and repeat the above steps if necessary. 5.3.4 - Disconnect the AC power to the instrument and replace the front panel by carefully inserting the digital panel meter terminals into the display socket J6. - The digital display is calibrated at the factory and should not require recalibration. Page 4

GE Sensing & Inspection Technologies Modus Model RPM-1 Room Pressure Monitor Installation Template 5.71 (145) 0.59 (15) Ø0.196 (5) Note: Dimensions are in inches (millimeters). 7.8 (198) Knockouts 0.196 (5) 2 places 1100 Technology Park Drive Billerica, MA 01821 Web: www.gesensing.com March 2008