Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Similar documents
Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Technical Information Cleanfit CPA472D

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Orbipore CPS91 and CPS91D

Orbisint CPS11 and CPS11D

Technical Information Cleanfit CPA871

Orbisint CPS12/CPS12D/CPS13

Ceraliquid CPS42/CPS42D/CPS43

Technical Information Cleanfit CPA451

Technical Information Cleanfit CPA875

Orbisint CPS11 and CPS11D

Technical Information

Ceraliquid CPS41 and CPS41D

Unifit CPA442. Technical Information. Process assembly For installation of 120 mm sensors in food and beverage, biotechnology and chemical industries

Technical Information Ceraliquid CPS41D and CPS41

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Operating Instructions Dipfit CPA111

Operating Instructions Cleanfit CPA871

ph-kompaktelektrodensystem sensopac CPA 320

Conductivity Measuring Cells ConduMax W CLS 19

Cleanfit P CPA474. Technical Information. Retractable plastic process assembly with ball valve for ph and ORP electrodes

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

SENSOFIT RET 5000 Technical Datasheet

Flowfit CYA251. Technical Information. Flow assembly for nitrate/sac, turbidity and oxygen sensors

Operating Instructions Cleanfit CPA875

EXNER PROCESS EQUIPMENT

Flow-Through Fitting ARF 215

Probe holders for analytical probes

Technical Information Cleanfit Control CYC25

PORTAELETTRODI HAMILTON

SCHOTT Instruments Process holders and accessories CHEMTRAC

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Oxymax W COS31. Brief Operating Instructions. Dissolved oxygen sensor

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Dissolved Oxygen, ph, and Conductivity

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

PN October Liquid Division. Mounting Solutions

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

Inline version with application-specific process adaptation

Level Limit Switch liquiphant FTL 365 / FTL 366

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Metal tube variable area flowmeter for gases, liquids and steam

SITRANS F M. Flow sensor MAG 1100 F 3/59

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

Flow Measurement SITRANS F M

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Conductivity Measurement CLM 280

Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

Operating Instructions Flexdip CYA112

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Digital ph transmitter

Conductivity Measuring Sensor InduMax H CLS 52

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

General Specifications

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194.

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Flow Measurement SITRANS F M

Digital ph transmitter

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Conductivity Sensors ConduMax W CLS 19

Level Limit Switch liquiphant FTL 360 / FTL 361

p Additional dimensions see section dimensions.

Mark 908 Series. Pressure Regulators Mark 908X Piloted Blanketing Regulators

Plastic tube variable area flowmeter for liquids and gases

General Purpose Toroidal Conductivity Sensors

SIPAN 32 and 34. Controllers, Sensors and Accessories for ph, ORP, Conductivity and Dissolved Oxygen

Electromagnetic Flow Monitor magphant

Technical specification

Thermowell for temperature sensors omnigrad M TW 13

Automatic filter AF 153 G

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

SATRON VTe pressure transmitter

Level Probe multicap DC 16

Thermocouple insert for Temperatur Sensor omniset- TPC 100

OPW Emergency Safety Disconnector. Safety Breakaway Coupling Type NTS-PU Series (Pull-Away) Sizes 1-4 (DN25 DN100) Page 1

RTD Temperature Sensor omnigrad T -TR 470

Product presentation SITRANS P310

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Inductive conductivity meter

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Accessories Guide ph/orp/conductivity Sensors

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Hydrostatic. Overview 192 VEGABAR series VEGAWELL Accessory 200. Hydrostatic VEGABAR series 60 and VEGAWELL

Combination ph/redox (ORP) Sensors

Combination ph/redox (ORP) Sensors

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Omnigrad T TR24. Technical Information. Modular RTD assembly threaded or weld-in compression fitting

Technical Information Liquiline System CAT810

PN /rev. B April Liquid Division. Mounting Solutions

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

INSERTION Adaptor for analysis

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

Transcription:

Technical Information Cleanfit W CPA450 Retractable assembly for 12 mm sensors for DO/pH/ORP measurement Application Pulp and paper industry Chemical industry Measurement in fibrous or coating media Tanks and process vessels Pipelines Power plants Wastewater treatment The retractable assembly permits replacement of ph/orp or oxygen sensors while the tank is full or under process conditions. Your benefits Easy installation and removal of the DO/pH/ORP sensor for easy service Sensor cleaning and calibraton without process interruption Process is sealed off reliably by a ball valve made of stainless steel Uses standard and ISFET sensors of 120 mm length 3 immersion depths up to 700 mm (27.5"), adjustable Safety equipment for operation up to 12 bar (175 psi) Integrated rinse and calibration connections Available as stainless steel, alloy C4 and titanium version TI183C/07/EN/13.11 71131108

Function and system design Function principle The assembly is manually operated. Caution! The rinse connections are in open contact with the medium in the measuring position and are thus exposed to the process pressure. Make sure that the rinse connections are closed during measurement and when moving the assembly. In the "Service" status (sensor moved back into the assembly and ball valve closed), the ball valve seals the assembly off from the process. This means that cleaning and calibration can take place and sensors can be changed under process conditions. In this "Service" status it is possible to clean the tank or pipe with a pressure up to 12 bar (175 psi). Caution! Manually moving the assembly under process conditions is only advised at a process pressure up to 4 bar (58 psi). 1 2 3 4 5 7 8 9 1 2 3 4 5 6 7 8 9 10 11 Cable protection Allen screw M5 Compression fitting (black) Lock ring (metal) Manual lever for ball valve opening and closing Immersion tube Setting collar for adjustment of immersion depth Drill holes for hook wrench Rinse connection G¼ (316L) NPT ¼ " (Alloy C4 or titanium) Sensor holder with protecting cage Locking device safety kit 6 11 10 Assembly in "measuring" position (ball valve open) a0010207 Assembly with safety kit a0011929 2 Endress+Hauser

Messen ATC Temperatur 25.0 C Wahl MEAS CAL DIAG? PARAM Hold Aus Cleanfit W CPA450 Suitable sensors The following sensors are suitable for installation in the CPA450: Digital sensors with Memosens technology, length 120 mm / 4.72" ph/orp glass electrodes, length 120 mm / 4.72" ISFET sensors: only sensors listed in "Accessories" chapter DO sensors, length 120 mm / 4.72" For the conductivity sensor CLS15 a modification is available Measuring system A complete measuring system consists of: Cleanfit W CPA450 assembly DO/pH/ORP sensor, length 120 mm (4.72"), e.g. Orbisint CPS11D Transmitter, e.g. Liquiline M CM42 or Mycom S CPM153 Measuring cable, e.g. CYK10 or CPK9 Optional: RM junction box for use with extension cable (see chapter "Accessories") CYK81 measuring cable for extended cable runs 1 3 4 ph 7.00 2 Measuring system with CPA450 1 Cleanfit assembly with sensor 2 Measuring cable 3 Liquiline M CM42 4 Mycom S CPM153 a0011680 Endress+Hauser 3

Installation Installation instructions The permissible installation angle of the assembly depends on the sensor: Glass electrodes and digital sensors with Memosens technology: Install the assembly at an angle of at least 15 from the horizontal. ISFET sensors: When using an ISFET sensor, there are, in principle, no restrictions to the installation. An installation angle between 0 and 180 is, however, recommended. A B 15 15 Installation angle of the assembly A Glass sensors: 15 to horizontal B ISFET sensors 0 to 180 recommended a0011679 Install the assembly so that the sensor is kept wet at all times. Installation with ball valve When replacing the sensor without switching off the process a ball valve is needed. The ball valve is part of the assembly (according to product structure) or has to be installed by the customer. Note! When used without ball valve switch off the process before removing the immersion tube or replacing the sensor. Danger of spraying liquid. A a0010209 Assembly in inserted position = measuring mode (ball valve open) a0010210 Assembly in retracted position for electrode replacement, calibration, rinsing (ball valve closed) A Top of adapter Note! Please note that a mounting clearance of min. 700 or 1150 mm (27.6" or 45.3") from the top of the adapter is required depending on assembly version. 4 Endress+Hauser

Environment Ambient temperature 0 to 80 C (32 to 176 F) Process Process pressure Process temperature Pressure-temperature load curve max. 12 bar at 100 C (175 psi at 212 F)) Caution! The maximum advised pressure for assembly movement is 4 bar (58 psi)! Consider the process conditions of the applied sensor! -15 to 130 C (5 to 266 F) Caution! Consider the maximum process temperature of the sensor! Pay attention to the specification of the process pressure! p [psi] p [bar] A 174 12 145 10 116 8 B 87 6 58 4 29 2-15 0 20 40 60 80 100 130 120 140 5 32 68 104 140 176 212 266 248 284 Pressure-temperature diagram A Maximum process operating pressure (static), only for completely installed assembly B Advised upper insertion/retraction pressure (functional) T [ C] T [ F] a0011650 Warning! The 4 bar (58 psi) line on the graph represents an advised upper insertion/retraction pressure. At 4 bar (58 psi) you have to apply (press/hold) approximately 20 kg (44 lbs) of force to the probe assembly. For insertion/retraction of the assembly at any process pressure, consider the following: Make sure the service conditions are suitable for insertion/retraction at the process pressure. Use locking device safety kit (see chapter "Accessories"). Note! Press/hold values are calculated based on ideal conditions (new assembly and clean fluid). Actual press/hold values could vary depending on process and/or assembly conditions. Note! To calculate the press/hold force use the following equation: press/hold force = line pressure in bar multiplied by the surface area factor 5 (e.g. 4 bar * 5 = 20 kg force) or press/hold force = line pressure in psi multiplied by the surface area factor 0.76 (e.g. 58 psi * 0.76 = 44 lbs force) Endress+Hauser 5

Design, dimensions Mechanical construction A B mm (inch) X X Z Ø 25 (0.98) 135 (5.31) Ø 21.2 (0.83) M23 + 1.5 Ø 27 (1.06) 46 (1.81) Y Y Z C D E 89 (3.5) 89 (3.5) X Y X X Z Z Z 140 (5.51) Y Y Dimensions (see the following table) a0010341 6 Endress+Hauser

Type Assembly Immersion depth mm (inch) X Adapter Y mm (inch) Z mm (inch) A CPA450-*A*** 100 (3.94) B CPA450-*B*** 100 (3.94) B CPA450-*C*** 100 (3.94) C CPA450-*D*** 100 (3.94) C CPA450-*E*** 100 (3.94) G1½ internal 536 (21.1) G1¼ external 536 (21.1) NPT 1¼" external 536 (21.1) Flange DN32 536 (21.1) Flange ANSI 1¼" 536 (21.1) 276 (10.9) 425 (16.7) 875 (34.5) 220 (9.06) 370 (14.9) 820 (32.6) 220 (9.06) 370 (14.9) 820 (32.6) 220 (9.06) 370 (14.9) 820 (32.6) 220 (9.06) 370 (14.9) 820 (32.6) D CPA450-*F*** and CPA450-*G*** 100 (3.94) G1¼ internal 536 (21.1) 130 (5.12) 280 (11.0) 730 (28.7) D CPA450-*H*** 100 (3.94) E CPA450-*I*** 100 (3.94) E CPA450-*K*** 100 (3.94) NPT 1¼" internal 536 (21.1) Flange DN32 536 (21.1) Flange ANSI 1¼" 536 (21.1) 130 (5.12) 280 (11.0) 730 (28.7) 100 (3.94) 100 (3.94) B CPA450-*M*** and CPA450-*Q*** M-NPT 1½ external 1143 (45.0) 830 (32.6) C CPA450-*N*** and CPA450-*R*** Flange ANSI 2" 1143 (45.0) 830 (32.6) Endress+Hauser 7

Weight Without ball valve: With threaded ball valve: With flanged ball valve: 2 kg (4.4 lb.) 5 kg (11 lb.) 10 kg (22.1 lb.) Materials in contact with medium Immersion tube: O-rings: Ball valve: Ball valve sealings: stainless steel AISI 316L, Alloy C4 or titanium EPDM / Viton / Kalrez stainless steel 1.4404 (AISI 316L) or 1.4408 (AISI CF-8M) PTFE Materials not in contact with medium Rinse connections Screws: Stainless steel AISI 316 Safety kit: Stainless steel AISI 316 Compression fitting: PA66GF Clamping ring: PEEK Handle: PVC Cable protection: Thermoplastic elastomer (TPE) For material 316L: 3 x G ¼ For material Alloy C4 or titanium: 3 x NPT ¼" 8 Endress+Hauser

Ordering information Product structure Immersion depth; material A 100 mm (3.93"); titanium with safety locking device; only for CPA450-*M*** or CPA450-*N*** B 250 mm (9.84"); titanium with safety locking device; only for CPA450-*M*** or CPA450-*N*** C 700 mm (27.56"); titanium with safety locking device; only for CPA450-*M*** or CPA450-*N*** H 100 mm (3.93"); Alloy C4 with safety locking device; only for CPA450-*Q*** or CPA450-*R*** I 250 mm (9.84"); Alloy C4 with safety locking device; only for CPA450-*Q*** or CPA450-*R*** K 700 mm (27.56"); Alloy C4 with safety locking device; only for CPA450-*Q*** or CPA450-*R*** 0 100 mm (3.93"); 316L 1 250 mm (9.84"); 316L 2 700 mm (27.56"); 316L 3 250 mm (9.84"); 316L with safety locking device 4 700 mm (27.56"); 316L with safety locking device Process connection and stop cock A Thread G 1¼ external, 316L; without adapter B Thread G 1¼ external, 316L C Thread NPT 1¼" external, 316L D Flange DN 32 PN 16; 316L E Flange ANSI 1¼", 150 lbs, 316L F Ball valve 316; thread G 1¼ internal G Ball valve 316L; thread G 1¼ internal H Ball valve 316; thread NPT 1¼" internal I Ball valve 316; flange DN 32 PN 16 K Ball valve 316; Fflange ANSI 1¼" M Thread M-NPT 1½", titanium, without ball valve N Flange ANSI 2", titanium, without ball valve Q Thread M-NPT 1½", Alloy C4, without ball valve R Flange ANSI 2", Alloy C4, without ball valve Material: Seals 1 EPDM 2 FPM, Viton 3 FFKM, Kalrez / PTFE Equipment, cable protection 10 With cable protection 16 Certificate EN 10204 3.1 for assembly without ball valve; with cable protection 20 Desiliconized, with cable protection 30 Certificate EN 10204 3.1 for assembly with ball valve (only for CPA450-*G***) 40 With safety pressure test, 20 bar at T = 20 C CPA450- complete order code Note! The certificate EN 10204 3.1 is not available for the material titanium. Versions with material Alloy C4 or titanium are delivered without ball valve. The ball valve has to be provided by the customer. Note! For sophisticated applications order the assembly with safety locking device. The safety locking device can also be ordered as locking device safety kit (see chapter "Accessories") Scope of delivery The scope of delivery comprises: Cleanfit W CPA450 assembly (ordered version) PMC (potential matching) mounting kit Hook wrench Allen key Operating Instructions (English) If you have any question, please contact your supplier or your local sales representatives. Endress+Hauser 9

Accessories Locking device safety kit Locking device safety kit Mechanical lock of the measuring position For applications in dusty or sooty areas For applications with vibrations or pressure surges Order no.: 71098681 a0015065 Assembly Hose nozzles for rinse connections G¼, DN 12 SS 1.4404 (AISI 316L), 2 pieces Order no.: 51502808 Hose nozzles for rinse connections G¼, DN 12 PVDF, 2 pieces Order no.: 50090491 Manometer Installation in rinse connection for checking the process pressure 0 to 16 bar (0 to 232 psi); G¼ Order no.: 71082362 Drain ball-valve for rinse chamber To drain residual medium; G¼; stainless steel 1.4408 (AISI CF-8M) Order no.: 71083041 Hook wrench DIN 1810 design B D 58-68 mm Order no.: 50090687 a0010362 10 Endress+Hauser

Process connection adapter Welding socket G 1¼ straight For process connections F and G Material: stainless steel 1.4571 (AISI 316Ti) Order no.: 51502284 50 (1.97) mm (inch) a0010396 Sensors Glass electrodes Note! When ordering electrodes, please note that only electrodes with a shaft length of 120 mm (4.72") and diameter of 12 mm (0.47") are suitable for the CPA450 assembly. The most common sensors are listed below. Orbisint CPS11/CPS11D ph electrode for process applications, with PTFE diaphragm Memosens functionality as option Ordering acc. to product structure, see Technical Information (TI028C/07/en) Orbisint CPS12/CPS12D ORP electrode for process applications, with PTFE diaphragm Memosens functionality as option Ordering acc. to product structure, see Technical Information (TI367C/07/en) Ceragel CPS71/CPS71D ph electrode with double chamber reference system and integrated bridge electrolyte Memosens functionality as option Ordering acc. to product structure, see Technical Information (TI245C/07/en) Ceragel CPS72/CPS72D ORP electrode with double chamber reference system and integrated bridge electrolyte Memosens functionality as option Ordering acc. to product structure, see Technical Information (TI374C/07/en) Orbipore CPS91/CPS91D ph electrode with open aperture for media with high dirt load Memosens functionality as option Ordering acc. to product structure, see Technical Information (TI375C/07/en) Endress+Hauser 11

ISFET sensors for CPA450 Tophit CPS471D Sterilisable and autoclavable ISFET sensor with Memosens technology for food and pharmaceutical industries, process technology, water treatment and biotechnology Ordering acc. to product structure, see Technical Information (TI283C/07/en) Tophit CPS491D ISFET sensor with Memosens technology, open aperture for media with high dirt load Ordering acc. to product structure, see Technical Information (TI377C/07/en) CPS471-ESA ph sensor with ISFET technology, ceramic diaphragm, chip seal: perfluorelastomer TOP68 / ESA plug-in head, 120 mm / 4.72" Order no.: 51513079 CPS491-ESA ph sensor with ISFET technology, open aperture, chip seal: perfluorelastomer TOP68 / ESA plug-in head, 120 mm / 4.72" Order no.: 51512562 Oxygen sensors Oxymax H COS21D Sterilizable sensor for dissolved oxygen, with Memosens technology Ordering acc. to product structure, see Technical Information (TI402C/07/en) Cables CPK1 special measuring cable For ph/orp electrodes with GSA plug-in head Ordering acc. to product structure, see Technical Information (TI118C/07/en) CPK9 special measuring cable For sensors with TOP68 plug-in head, for high-temperature and high-pressure applications, IP 68 Ordering acc. to product structure, see Technical Information (TI118C/07/en) CPK12 special measuring cable For ph/orp glass electrodes and ISFET sensors with TOP68 plug-in head Ordering acc. to product structure, see Technical Information (TI118C/07/en) CYK10 Memosens data cable For digital sensors with Memosens technology Ordering according to product structure, see Technical Information (TI376C/07/en) CYK71 measuring cable Non-terminated cable for the connection of ph sensors and COS41 oxygen sensor or the extension of sensor cables Sold by the meter, order number: non-ex version, black: 50085333 Ex version, blue: 51506616 CYK81 measuring cable Non-terminated measuring cable for extension of sensor cables of e.g. Memosens sensors, CUS31/CUS41 2 wires, twisted pair with shield and PVC-sheath (2x2x 0.5 mm 2 + shield) Sold by the meter, order no.: 51502543 Junction box VBA For cable extension of ph/orp sensors 10 terminals, protection class: IP 65 (i NEMA 4X) Cable entries: 2 x Pg 13.5, 2 x Pg 16 Material: polycarbonate Order no.: 50005276 Junction box RM For cable extension (e.g. for Memosens sensors) 5 terminals Cable entries: 2 x Pg 13.5 Material: PC Ingress protection: IP 65 Order no.: 51500832 12 Endress+Hauser

Transmitters Liquiline CM42 Modular two-wire transmitter, stainless steel or plastic, field or panel instrument Various Ex approvals (ATEX, FM, CSA, Nepsi, TIIS) HART, PROFIBUS or FOUNDATION Fieldbus available Ordering acc. to product structure, see Technical Information (TI381C/07/en) Liquisys CPM223/253 Transmitter for ph and ORP, field or panel-mounted housing HART or PROFIBUS available Ordering acc. to product structure, see Technical Information (TI194C/07/en) Mycom CPM153 Transmitter for ph and ORP, one or two channel version, Ex or non-ex HART or PROFIBUS available Ordering acc. to product structure, see Technical Information (TI233C/07/en) Endress+Hauser 13

14 Endress+Hauser

Endress+Hauser 15

Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI183C/07/EN/13.11 71131108 Printed in Germany / FM+SGML 6.0 / DT