General + Definite Purpose Contactors

Similar documents
General + Definite Purpose Contactors

Technical Information

Technical Information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

Technical Information

The contactor for large horsepower applications

Series CA5 Contactors

Technical Information

and Refrigeration Institute). CNX Special Purpose Contactors

Series CA6 Contactors

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

AF series contactors (9 2650)

AF series contactors (9 2650)

Contactor Types CI 61-98

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Mini Contactors CI 4-

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Series L9 UL489 Miniature Circuit Breakers

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Page 2-4 Page 2-8. Page Page 2-12

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI Contactors and motor starters Types CI 61 - CI 98

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Switches Unlimited Phone: * Fax:

Bulletin 100-D IEC Contactors

All round protection guaranteed

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

3RT14 Contactors with 3 Main Contacts

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Page 2-4 Page 2-8. Page Page 2-13

Manual Motor Protectors

A200 NEMA Contactors and Starters A200

Short form catalogue. Motor protection & control

Series L9 UL-489 Miniature Circuit Breakers

CI-TI Contactors and Motor Starters Type CI 6-50

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Description. Positive safety relays

Selection Guide Motor Control Device Solutions

Micro Contactor MA Series

BETA Switching Switches and Light Indicators

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

1489-M Circuit Breakers

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

4 - Miniature controls

KT4 Manual Motor Starter

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Manual motor starter MS116

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

AF40... AF96 3-pole contactors Technical data

Ideal for use as a manual starter

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

FMotor Circuit Controllers

Electrical sector solutions E Line family. Industry leading design in a compact package

Star Series Motor protection & control

Rotary Cam Switches. Rotary Cam Switches

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Industrial Contactors CTX 3 3P 185A - 800A

MS25, MST25, MS20, MST20

Application Mini Contactors for Motors and Resistive Loads

For many applications

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Product Selection 3-Pole Contactors

Control Circuit Protection

Controls. CONTACTORS CWB Line (up to 40A)

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Technical Information

Manual Motor Starters. Meta-MEC

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Phone: Fax: Web: -

Electrical sector solutions E Line family. Industry leading design in a compact package

ASL09..S 3-pole Contactors - Spring Terminals

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V)

AE 9... AE 40 Contactors NE... Contactor Relays

Manual motor starter MS132

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE

SENTRON Switching and Protection Devices Switch Disconnectors

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4

Essential equipment for all your requirements

Series CA7 Contactors

SIRIUS. Answers for industry.

Meta Solution. Contactors and Overload relays

Contactor TECHNICAL INFORMATION - FRAME 1

Series CA6 Contactors

ACS motor protection circuit breakers KT 7 Introduction

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MS General Information Extended Product Type: MS

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

3. Coils shall be of molded construction

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

TAE pole Contactors

Transcription:

General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3 ccessories... 2 Contactor Cross Reference... 23 Technical Information & Dimensions (Online)... 24 Series C7 Contactors... 30 Reversing... 37 Special Use C7 Contactors... 40 CNX Special Purpose... 4 NEM Labeled Contactors... 42 C7Y2 Wye-Delta Contactors... 44 CL7 Lighting Rated... 45 ccessories... 47 Renewal Coils... 56 Contactor Cross Reference... 58 Technical Information & Dimensions (Online)... 59 Series C9 Contactors... 90 ccessories... 93 Contactor Cross Reference... 98 Technical Information & Dimensions (Online)... 99 Series C6 Contactors (Discontinued)... 20 ccessories... 29 Renewal Coils... 34 Contactor Cross Reference... 37 Technical Information & Dimensions (Online)... 38 Series C5 Contactors (Discontinued)... 56 ccessories... 59 Renewal Coils... 6 Technical Information & Dimensions (Online)... 63 Series CDP2 Definite Purpose Contactors... 78 ccessories... 84 Technical Information & Dimensions (Online)... 85

Contactors Contactors General Purpose and Definite Purpose rugged and comprehensive range of contactors from 5 to 900 HP Sprecher+Schuh IEC contactors are designed and manufactured in plants that are quality certified to international standard ISO 900 Sprecher + Schuh s broad line of general purpose contactors combine performance and reliability in space saving designs that are well proven and used the world over. Sprecher + Schuh s IEC design is dimensionally among the smallest devices in the industry. range of definite purpose contactors is also available, providing reliable and economic performance in commercial applications. Economy and selection Four different contactor families provide a wide variety of contactor sizes, one for practically every horsepower increment! The ability to select intermediate sizes assures a closer match for your motor and provides economy not found with traditionally sized devices. Definite purpose contactors are available in one, two, three and four pole, up to 90. Precisely match the contactor to the application Unique to IEC-style contactors is the ability to select the exact device required for a specific application. By identifying the conditions under which the contactor will be used, i.e., resistive loads, reversing, inching and plugging, etc., published life-curve data predicts contact life in millions of operations. This information enables you to select the precise contactor for your application without buying too much or too little. Designed for long life Destructive electrical arcs are common when opening or breaking the contacts of larger contactors. Sprecher + Schuh general purpose contactors are designed to dramatically reduce electrical arcing by quickly guiding the arc off of the contacts and into specially designed arc chutes. This special design divides and eliminates the electrical arcs quickly, significantly increasing contact life and assuring reliable operation. Limitless choices comprehensive selection of modular accessories is available for all contactor families, which allows infinite contactor and starter combinations, both open and enclosed. Safety in mind Virtually all Sprecher + Schuh contactors are designed to be safe from accidental contact with the finger or back-of-hand. On the smaller contactors, terminals and set screws are recessed, while larger devices (up to Series C9) accept terminal covers that provide protection according to VDE 006, Part 00. Manufactured to rigorous quality standards Sprecher + Schuh contactors are designed and manufactured in plants that maintain quality certification to the rigorous international standards, ISO 900. Sprecher + Schuh manufacturing facilities renew ISO certification every three years by passing an exacting quality assurance audit. International standards and approvals ll Sprecher+Schuh IEC contactors are culus CS pproved, along with several other certifications. They also carry the CE Mark and meet IEC 60947- requirements. They are approved in virtually every international market. 2

7.5HP 50HP 75HP 900HP GENERL P URPOSE C8 Series Contactor Provides commercial-grade performance for motors up to 7.5 HP Features low-profile design and 45mm width Maintains narrow width with modular, snap-on accessories Performs up to 700,000 electrical and 5,000,000 mechanical operations C7 Series Contactor Covers up to 75HP industrial applications Features small dimensions, as little as 45mm wide Uses interchangeable accessories for all contactor sizes Provides flexibility with reversible coils for group installation Has dual-cage clamp lugs on C7-30 and larger units Designed and tested with respect to Type and 2 Coordination C9 Series Contactor Covers up to 900HP industrial applications Provides a dimensional advantage with a smaller size and footprint Contactors Features a universal electronic C/DC coil Has various application selections, with IEC solutions up to 2650 Includes expanded certifications Provides extended life with arc quenching technology DEFINITE P URPOSE CDP2 Definite Purpose Contactors Covers commercial applications up to 90 / 50HP vailable in one, two, three and four pole Meet or exceed electrical and mechanical requirements defined by definite purpose contactor standards Three convenient wire connection methods 3

Contactors Motor Current Rating Chart for Full Load mps C Induction Motors Horsepower Single Phase Three Phase 5 Volt 230 Volt 200 Volt 230 Volt 380-45 Volt 460 Volt 575 Volt @ 60 HZ @ 60 HZ @ 60 HZ @ 60 HZ @ 50 HZ @ 60 HZ @ 60 HZ /6 4.4 2.2 ~ ~ ~ ~ /4 5.8 2.9 ~ ~ ~ ~ /3 7.2 3.6 ~ ~ ~ ~ /2 9.8 4.9 2.5 2.2.3. 0.9 3/4 3.8 6.9 3.7 3.2.8.6.3 6.0 8.0 4.8 4.2 2.3 2..7 /2 20.0 0.0 6.9 6.0 3.3 3.0 2.4 2 24.0 2.0 7.8 6.8 4.3 3.4 2.7 3 34.0 7.0.0 9.6 6. 4.8 3.9 5 56.0 28.0 7.5 5.2 9.7 7.6 6. 7 /2 80.0 40.0 25.3 22.0 4.0.0 9.0 0 00 50.0 32.2 28.0 8.0 4.0.0 5 35 68.0 48.3 42.0 27.0 2.0 7.0 20 ~ 88.0 62. 54.0 34.0 27.0 22.0 25 ~ 0 78.2 68.0 44.0 34.0 27.0 30 ~ 36 92.0 80.0 5.0 40.0 32.0 40 ~ 76 20 04 66.0 52.0 4.0 50 ~ 26 50 30 83.0 65.0 52.0 60 ~ ~ 77 54 03 77.0 62.0 75 ~ ~ 22 92 28 96.0 77.0 00 ~ ~ 285 248 65 24 99.0 25 ~ ~ 359 32 208 56 25 50 ~ ~ 44 360 240 80 44 75 ~ ~ 475 43 275 207 68 200 ~ ~ 552 480 320 240 92 250 ~ ~ 692 604 403 302 242 300 ~ ~ ~ 722 482 36 289 350 ~ ~ ~ 828 560 44 336 400 ~ ~ ~ 954 636 477 382 450 ~ ~ ~ 030 7 55 42 500 ~ ~ ~ 80 786 590 472 The information in this chart was derived from Table 50. of UL standard 508. The voltages listed are rated motor voltages. The currents listed shall be permitted for system voltage ranges of 0-20, 220-240, 380-45, 440-480 and 550-600 volts. The full-load current values are for motors running at usual speeds and motors with normal torque characteristics. Motors built for especially low speeds or high torques may have higher full-load currents, and multi-speed motors will have full-load currents varying with speed. In these cases, the nameplate current ratings shall be used. Caution: The actual motor amps may be higher or lower than the average values listed above. For more reliable motor protection, use the actual motor current as listed on the motor nameplate. Use this table as a guide only. 4

Contactor HP Rating Table for C Motors UL / CS Maximum HP Rating Selection ➊ Sprecher + Schuh Contactor Series Single Phase Maximum Horsepower Three Phase 5 Volt 230 Volt 200 Volt 230 Volt 460 Volt 575 Volt C7-9 /2 /2 2 2 5 7-/2 C7-2 /2 2 3 3 7-/2 0 C7-6 3 5 5 0 5 C7-23 2 3 5 7-/2 5 5 C7-30 2 5 7-/2 0 20 25 C7-37 3 5 0 0 25 30 C7-43 3 7-/2 0 5 30 30 C7-55 5 0 5 20 40 40 C7-60 5 0 5 20 40 50 C7-72 5 5 20 25 50 60 C7-85 7-/2 5 25 30 60 60 C7-97 0 20 30 30 75 75 6(-EI) ~ ~ 30 40 75 00 46(-EI) ~ ~ 40 50 00 25 90(-EI) ~ ~ 50 60 05 50 205(-EI) ~ ~ 60 75 50 200 265(-EI) ~ ~ 75 00 200 250 305(-EI) ~ ~ 00 25 250 300 370(-EI) ~ ~ 25 50 300 350 400-EI ~ ~ 25 50 300 400 460-EI ~ ~ 50 200 400 500 580-EI ~ ~ 200 250 500 600 750-EI ~ ~ ~ 300 600 700 860-EI ~ ~ ~ 400 800 000 060-EI ~ ~ ~ 450 900 50 Contactors NEM Size Labeled Selection NEM Size Sprecher + Schuh Contactor Series Single Phase Maximum Horsepower Three Phase 5V 230V 200V 230V 460V 575V 00 CN7-2 /3 -/2 -/2 2 2 0 CN7-6 2 3 3 5 5 CN7-37 2 3 7-/2 7-/2 0 0 2 CN7-43 3 7-/2 0 5 25 25 3 CN7-85 7-/2 5 25 30 50 50 ➊ EI designation indicates coil has electronic interface capability with a PLC. 5

Contactor HP Rating Table for DC Motors Contactors DC Motor Ratings Table 50.2 Full-load motor-running currents in amperes corresponding to various DC horsepower ratings Table 50.2 effective pril 25, 2003 Horsepower 90 Volts 0-20 Volts 80 Volts 220-240 Volts 500 Volts 550-600 Volts /0 ~ 2.0 ~.0 ~ ~ /8 ~ 2.2 ~. ~ ~ /6 ~ 2.4 ~.2 ~ ~ /4 4.0 3. 2.0.6 ~ ~ /3 5.2 4. 2.6 2.0 ~ ~ /2 6.8 5.4 3.4 2.7 ~ ~ 3/4 9.6 7.6 4.8 3.8 ~.6 2.2 9.5 6. 4.7 ~ 2.0 -/2 ~ 3.2 8.3 6.6 ~ 2.7 2 ~ 7 0.8 8.5 ~ 3.6 3 ~ 25 6 2.2 ~ 5.2 5 ~ 40 27 20 ~ 8.3 7-/2 ~ 58 ~ 29 3.6 2.2 0 ~ 76 ~ 38 8 6 5 ~ 0 ~ 55 27 24 20 ~ 48 ~ 72 34 3 6

General Information Industrial Control Equipment - UL508 Table 39. Rating Codes for C Control-Circuit Contacts at 50 and 60 Hz ➍ Contact Rating Code Designation ➊ Thermal continuous test current mperes Maximum current, amperes ➋ 20 Volt 240 Volt 480 Volt 600 Volt Maximum volt- mperes Make Break Make Break Make Break Make Break Make Break 50 0 60 6.00 ~ ~ ~ ~ ~ ~ 7200 720 300 0 60 6.00 30 3.00 ~ ~ ~ ~ 7200 720 600 0 60 6.00 30 3.00 5.50 2.20 7200 720 Contactors B50 5 30 3.00 ~ ~ ~ ~ ~ ~ 3600 360 B300 5 30 3.00 5.50 ~ ~ ~ ~ 3600 360 B600 5 30 3.00 5.50 7.50 0.75 6 0.60 3600 360 C50 2.5 5.5 ~ ~ ~ ~ ~ ~ 800 80 C300 2.5 5.5 7.5 0.75 ~ ~ ~ ~ 800 80 C600 2.5 5.5 7.5 0.75 3.75 0.375 3.00 0.30 800 80 D50.0 3.60 0.60 ~ ~ ~ ~ ~ ~ 432 72 D300.0 3.60 0.60.80 0.30 ~ ~ ~ ~ 432 72 E50 0.5.80 0.30 ~ ~ ~ ~ ~ ~ 26 36 Table 39.2 Rating Codes for DC Control-Circuit Contacts ➍ Contact Rating Code Designation ➊ Thermal continuous test current amperes Maximum make or break current, mperes ➌ 25 Volt 250 Volt 30 to 600 Volt Maximum make or break volt- mperes at 300 volts or less N50 0 2.2 ~ ~ 275 N300 0 2.2. ~ 275 N600 0 2.2. 0.40 275 P50 5.0. ~ ~ 38 P300 5.0. 0.55 ~ 38 P600 5.0. 0.55 0.20 38 Q50 2.5 0.55 ~ ~ 69 Q300 2.5 0.55 0.27 ~ 69 Q600 2.5 0.55 0.27 0.0 69 R50.0 0.22 ~ ~ 28 R300.0 0.22 0. ~ 28 ➊ The numerical suffix designates the maximum voltage design values, which are to be 600, 300, and 50 volts for suffixes 600, 300, and 50 respectively. Test voltage shall be 600, 250, or 25 volts. ➋ For maximum ratings at voltages between the maximum design value and 20 volts, the maximum make and break ratings are to be obtained by dividing the volt-amperes rating by the application voltage. For voltages below 20 volts, the maximum make current is to be the same as for 20 volts, and the maximum break current is to be obtained by dividing the break voltamperes by the application voltage, but these currents are not to exceed the thermal continuous test current. ➌ For maximum ratings at 300 volts or less, the maximum make and break ratings are to be obtained by dividing the voltampere rating by the application voltage, but the current values are not to exceed the thermal continuous test current. ➍ Data tables extracted from UL508 Standards for Industrial Control Equipment. 7

Contactors Predicting Electrical Life Sprecher + Schuh contactors are designed for superior performance in a wide variety of applications, by giving consideration to the specific load, utilization category and required electrical life, you can purchase exactly the type General Information How to read Contact Life Curves and size of contactor required. This assures reliable operation and high value the ability to very closely match the contactor to the application. ➀ Identify the appropriate utilization category. For this example, we will determine C7 contact life for inching and plugging squirrel-cage motors. ➊ Utilization Category Definition C- Resistance Furnaces Non inductive or slightly inductive loads, Resistive Furnaces C-2 Slip-ring motors Starting and stopping of running motors C-3 Squirrel-cage motors Starting and stopping of running motors C-4 Squirrel-cage motors Starting, plugging, and inching (Plugging is understood as stopping or reversing the ➀ motor rapidly by reversing the motor primary connections while the motor is running. Inching [or jogging] is understood as energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism.) C-5 Electromagnets Electromagnets for contactors, valves, solenoid actuators Squirrel-cage motors: starting, plugging, inching Ue = 230 460 VC ➁ Choose the graph for the utilization category selected. (a graph pertaining to most Utilization Categories can be found in each contactor section.) ➃ 0 C7-23 C7-6 C7-2 C7-30 C7-37 C7-43 C7-60 C7-72 C7-85 C7-97 C-4 ➁ ➂ ➃ Locate the Rated Operational Current (Ie) along the bottom of the chart and follow the graph lines up to the intersection of the appropriate contactor s life-load curve. Read the estimated contact life along the vertical axis. ➋ Contact Life (Millions of Operations) 0. C7-9.0 0 Rated Operating Current Ie C-4 [] ➂ 00 ➊ comprehensive list of Utilization Categories can be found in each contactor section, however, these are the primary categories used in most industrial motor applications. ➋ The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 60947-4-. Since contact life in a given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 8

Determining Contact Life To determine the contactor s estimated electrical life, follow these guidelines:. Identify the appropriate Utilization Category from Table. 2. In the technical pages for each contactor size, choose the graph for the Utilization Category selected. General Information How to read Contact Life Curves 3. Locate the Rated Operational Current (l e ) along the bottom of the chart and follow the graph lines up to the intersection of the appropriate contactor s life-load curve. 4. Read the estimated contact life along the vertical axis. Contactors Table IEC Special Utilization Categories, C Ratings ➊ CONTCTORS Category Typical pplications C- C-2 C-3 C-4 C-5a Non-inductive or slightly inductive loads; resistance furnaces Slip-ring motors: Starting, plugging Slip-ring motors: Starting, switching off motors during running Squirrel-cage motors: Starting, plugging, inching ➎ Switching of electric discharge lamp control Rated Current Conditions for testing electrical life Conditions for testing making and breaking capacity Make Break Ops. Make Break I/Ie U/ue cos Ic/Ie Ur/Ue cos I/Ie U/ue cos Ic/Ie U/ue cos ll values 0.95 0.95 6000.5.05 0.8.5.05 0.8 50 ll values 2.05 0.65 2.05 0.65 6000 4.05 0.65 4.05 0.65 50 Ie 7mp 7mp <Ie 00mp Ie> 00mp Ie 7mp 7mp <Ie 00mp Ie> 00mp 6 6 6 6 6 6 0.65 0.35 0.35 0.65 0.35 0.35 6 6 6 0.7 0.7 0.7 0.65 0.35 0.35 0.65 0.35 0.35 6000 6000 0 0 8 ➋ 2 2 0 ➍...... 0.65 0.35 0.35 0.65 0.35 0.35 8 8 6 ➌ 0 0 8 ➋...... 0.65 0.35 0.35 0.65 0.35 0.35 2.05 0.45 2.05 0.45 6000 3.05 0.45 3.05 0.45 50 C-5b Switching of incandescent lamps.05.05 6000.5.05.5.05 50 C-6a Switching of transformers Rating derived from C-3 rating (x 0.45) Ops. 50 50 CONTROL DEVICES SWITCHES C-6b Switching of capacity banks Depends on circuit conditions of application C-2 Control of resistive loads and solid state loads with isolation by ll values 0.9 0.9 6050 opto couplers C-3 Control of solid state loads 2 0.65 0.65 6050 with transformer isolation 0. 0.65.. 0.65 0 C-4 Control of small electromagnetic loads 72 V 6 0.3 0.3 6050 6. 0.7 6. 0.7 0 C-5 Control of electromagnetic loads 72 V 0 0.3 0.3 6050 0. 0.3 0. 0.3 0 C-20 Connecting and disconnecting under no load conditions No testing required C-2 Switching or resistive loads, including moderate overloads ll values 0.95 0.95 0000.5.05 0.95.5.05 0.95 5 Switching of mixed resistive & C-22 inductive loads, including moderate ll values 0.8 0.8 0000 3.05 0.65 3.05 0.65 5 overloads C-23 Switching of motor loads or other highly inductive loads ll values 0.65 0.65 0000 0.05 0.45 8.05 0.45 5 Legend Ue Rated operational voltage U Voltage before make Ur Recovery voltage Ie Rated operational current I Making current Ic Breaking current L Inductance of test circuit R Resistance of test circuit ➊ Utilization categories and test conditions for C & DC. For contactors according to IEC 58-, starters according to IEC 292-... 4 and control switches according to IEC 337- and IEC 337-. ➋ With a minimum value of 000 for I or Ic. ➌ With a minimum value of 800 for Ic. ➍ With a minimum value of 200 for I. ➎ Plugging is understood as stopping or reversing the motor rapidly by reversing the motor primary connections while the motor is running. Inching [or jogging] is understood as energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. 9

Contactors Determining Contact Life To determine the contactor s estimated electrical life, follow these guidelines:. Identify the appropriate Utilization Category from Table. 2. In the technical pages for each contactor size, choose the graph for the Utilization Category selected. General Information How to read Contact Life Curves 3. Locate the Rated Operational Current (l e ) along the bottom of the chart and follow the graph lines up to the intersection of the appropriate contactor s life-load curve. 4. Read the estimated contact life along the vertical axis. Table IEC Special Utilization Categories, DC Ratings ➊ Category Typical pplications DC- DC-2 DC-3 DC-4 DC-5 DC-5 Non-inductive or slightly inductive loads, resistance furnaces Shunt-motors: Starting, switching off motors during running Shunt motors: Starting, plugging, inching Series-motors: Starting, switching off motors during running Series-motors: Starting, plugging, inching Electromagnets for contactors, valves, solenoid actuators Rated Current Conditions for testing electrical life Conditions for testing making and breaking capacity Make Break Ops. Make Break I/Ie U/ue cos Ic/Ie Ur/Ue cos I/Ie U/ue cos Ic/Ie U/ue cos ll Values.5 ➋. ➋ ➋.5 ➋. ➋ ➋ ll Values 2.5 2 0. 7.5 4. 2.5 4. 2.5 ll Values 2.5 2 2.5 2 4. 2.5 4. 2.5 ll Values 2.5 7.5 0.3 0 4. 5 4. 5 ll Values 2.5 7.5 2.5 7.5 4. 5 4. 5 ll Values 6 x P ➌ 6 x P ➌.. 6 x P ➌.. 6 x P ➌ Ops. C7 Contactors for Elevator Duty Minimum Operational Life Contactor Cycles C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 500,000 ➍➎ C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 CNX Special Purpose Contactor Minimum Operational Life in Resistive pplications Contactor Cycles CNX-205 CNX-205 CNX-206 250,000 ➍ CNX-207 CNX-208 CNX-209 CNX-22 00,000 ➍ CNX-28 Legend Ue Rated operational voltage U Voltage before make Ur Recovery voltage Ie Rated operational current I Making current Ic Breaking current L Inductance of test circuit R Resistance of test circuit ➊ Utilization categories and test conditions for C & DC. For contactors according to IEC 58-, starters according to IEC 292-... 4 and control switches according to IEC 337- and IEC 337-. ➋ Only according to VDE. ➌ P = Ue x Ie rated power [W]. The value 6 x P has been derived from an empiric relationship which covers most magnetic loads for DC up to an upper limit of P = 50W. ➍ Life data shown are the minimum test requirements per UL/CS. ctual life in application may exceed these values. ➎ Value pending on 55 and 97 contactors at time of this printing. 0

Contactor Catalog Numbers Sprecher+Schuh employs a catalog number coding system for contactors (and many other devices) that follows a logical pattern, where every digit signifies a specific device attribute. Where indicated, the use of dashes ( ) serves to separate device characteristics and should always be used when ordering. General Information Open Contactors The following example illustrates all of the possible combinations when specifying contactors and reversing contactors (open type only). See Section C for an explanation of the catalog number coding system for enclosed contactors and starters. Contactors C 7-2 - 0-20 C CU CN Configuration C(V)L CNX C_Y2 Contactor Reversing Contactor NEM Labeled Contactor Lighting Contactor Special Purpose Contactor Elevator Wye-Delta Contactor Series Series C8 8-09(C) 8-2(C) Series C7 ➊ 7-9(E) 7-2(E) 7-6(E) 7-23(E) 7-30(E) 7-37(E) 7-40(E) 7-43(E) 7-55(E) 7-60(D) 7-72(D) 7-85(D) 7-90(D) 7-97(D) Series C9 ➋ 9-6(-EI) 9-46(-EI) 9-90(-EI) 9-205(-EI) 9-265(-EI) 9-305(-EI) 9-365(-EI) 9-400-EI 9-460-EI 9-580-EI 9-750-EI 9-860-EI 9-060-EI 9-260-EI 9-2050-EI 9-2650-EI uxiliary Contacts -0 N.O. uxiliary -0 N.C. uxiliary - N.O. & N.C. uxiliary -02 2 N.C. uxiliaries -22 2 N.O. & 2 N.C. ux. -00 No uxiliaries 4-pole C7 & C8 Contactors ➌ -M40 4 N.O. Power Poles -M3 3 N.O. Power Poles/ N.C. Power Pole -M22 2 N.O. Power Poles/ 2 N.C. Power Poles C 24Z 20 208 220W 240 277 380 480 600 Coil Code DC 2E, 2DD 24E, 24DD 24W 36E 48E, 48DD 0E, 0DD 220E, 220DD C/DC 24W 48W 20W 480W This illustration is for reference only. Turn to the appropriate page to determine specific catalog number. ➊ (D) and (E) suffix designates DC contactors. ➋ (-EI) suffix indicates electronic coil. Optional on 6 365, standard on 400 2650. ➌ On four pole contactors, this number designates main power pole configuration.

General Information Contactors Notes 2

Series C8 Contactors and CT8 Starters n ingenious miniature contactor and starter system Sprecher + Schuh s C8 Series of miniature contactors and starters provide an extremely compact and reliable method of controlling motors of 7.5 HP or less (@460V). The C8 is an economical choice for applications where space is limited or where a minimal enclosure is desired. Small but rugged Even though their contacts and coils are not replaceable, Sprecher + Schuh has subjected this series of contactors to monitored endurance tests that demonstrate their ruggedness. t full load, under 3-phase power, the contacts in the C8 have an electrical life of 700,000 operations, while the C magnet system has a mechanical life of 5,000,000 operations. The CT8 Starter Efficient and reliable This miniature starter features the new CT8 Thermal Overload Relay. complex current limiting calibration procedure performed after each unit ensures the consistent high quality of Sprecher + Schuh s thermal overload relay. Today s Class 0 T-frame design, like the CT8 Series, has been recognized by many motor manufacturers as the ideal type to assure optimum motor protection due to less use of copper and iron. all auxiliary contact blocks can be snapped-on or removed without changing any existing power wiring. Other accessories include a snap-on RC Link (surge suppressor), mechanical interlocks and space saving adaptors for connecting auxiliary components. Effortless installation Both the C8 Contactor and the CT8 Starter are DIN-rail mountable for instant installation and modification. Fittings are also included on the C8 for base mounting. ll terminals are clearly marked and shipped in the open position for installation with either manual or power screwdrivers. C8 Contactors ccessories require no additional panel space CT8 starters feature the CT8 thermal overload. The entire C8 System is logically engineered. Modular accessories like auxiliary contact blocks snap-on without increasing the C8 s original width of 45mm. lso, due to its horizontal switching movement, the basic contactor has the same low profile whether an C or DC operating magnet is used. This permits the use of enclosures with shallow mounting depths. Once the C8 is installed, 45mm ( 7/6 ) 9 2 3

Miniature Contactors Series C8 C8 Contactors Series C8 Miniature Contactors, Starters, Overloads & Industrial Relays Rated 690V RoHs Compliant Conforming to U.S., Canadian, and IEC Standards Same Dimensions for C and DC Pluggable Surge Suppressor Modules Suppressor modules are simply plugged on the front of the contactors, next to the auxiliary contact blocks. No wiring required. Fast and easy installation. uxiliary Contact Reliability Bifurcated, gni (silver/nickel) plated contacts for high contact reliability for 2m/5V electronic signals. H-shaped self cleaning auxiliary contacts provide a 4-way current path ensure high contact reliability for low energy switching. 4

25% 0% 00% 85% 7% Miniature Starters Series C8.30 V SFETY MRGIN FOR OVER VOLTGE.26,4 V IEC/EN 60947: C8 Mini.24 V 85% - 0% 7% - 25%.20,4 V SFETY MRGIN FOR UNDER VOLTGE.7 V VOLTGE C8 Contactors High Performance C & DC Coils Wide range DC coils can provide reliability in case of over- and under-voltage, a common issue with battery-fed control power supply systems. The low coil consumption allows the contactors to be directly controlled via a PLC. Optional, integral factory-installed surge suppressor modules for C and DC for limiting coil switching transients. MIRROR ND MECHNICLLY LINKED DESIGN 3 5 2 23 3 Main Contacts uxiliary contacts Off 2 2 4 6 22 24 32 a a C8: mechanically linked performance between main contacts and internal auxiliary contacts as per IEC 60947-5-. This feature provides status feedback in the event of a contact weld. 2a 0.5 mm ll round Safety 2a 0.5 mm C8/uxiliary contacts: mechanically linked performance between main contacts and auxiliary contacts as per IEC 60947-5- for C8 models with DC coils. Mechanically linked provides status feedback in the event of a contact weld. Mirror contact between main and auxiliary contacts as per IEC 60947-4- for C8 models with C coils. Mirror contacts prevent any unclear status indications if a N.O. power pole welds. 5

C8 Contactors Non-Reversing, Three Pole Contactors With C Coil, Series C8 (Open type only) ➊➐ I e [] 40ºC Ratings for Switching C Motors (C2 / C3 / C4) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø uxiliary Contacts per Contactor Miniature Contactors - C & DC Coil Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 20 3 4 4 4 /2 -/2 2 2 5 5 0 C8-09-0-99 0 C8-09-0-99 20 3 5.5 5.5 5.5 3/4 2 3 3 7-/2 7-/2 0 C8-2-0-9 0 C8-2-0-9 C8-09-0 contactor Series C8 Non-Reversing, Three Pole Contactors With DC Coil, Series C8 (Open type only) ➊➋➐ I e [] 40ºC Ratings for Switching C Motors (C2 / C3 / C4) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø uxiliary Contacts per Contactor Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 20 3 4 4 4 /2 -/2 2 2 5 5 0 C8-09C-0-2 0 C8-09C-0-2 20 3 5.5 5.5 5.5 3/4 2 3 3 7-/2 7-/2 0 C8-2C-0-52 0 C8-2C-0-52 C Coil Codes ➊➌ C Coil Code Voltage Range 50 Hz 60 Hz 2 2V 2V 24Z 24V 24V 48Z 48V 48V 20 0V 20V 208 200V-220V 208V-220V 240 240V 240V 380 ➎ Use Coil Code 400 400 ➎ 400V 400V 480 440V 480V 575 ➏ Use Coil Code 600 600 ➏ 525V 600V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code DC Coil Codes ➊➌ DC Coil Code Voltage 2D 2V 24D 24V ➍ 0D 0V 25D 25V 220D 220V See Coil Codes on this page ➊ C8 not available without coil. Coils and contacts not replaceable. ➋ Select Coil Code from DC Coil Code table only. ➌ The coil codes shown are the most commonly stocked items. Contact your Sprecher + Schuh representative to determine if other voltages are available. ➍ Integrated diode surge suppressor coils available. Order coil code 24DD. Example: C8-09C-0-24D becomes C8-09C-0-24DD. dd $37 to list price. ➎ The European Community has agreed that 400V is the nominal voltage in lieu of 380V. Use this code when 380V is required. ➏ Use this code for 575V applications. ➐ See page 27 regarding mechanically linked contacts and mirror contact performance. 6

Non-Reversing, Four Pole Contactors With C Coil, Series C8 (Open type only) ➊➍➑ I e [] 40ºC Ratings for Switching C Motors (C2 / C3) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø Contact configuration main poles Miniature Contactors - C & DC Coil Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 4 0 C8-09-M40-99 20 3 4 4 4 /2 -/2 2 2 5 5 3 C8-09-M3-4 2 2 C8-09-M22-4 4 0 C8-2-M40-9 20 3 5.5 5.5 5.5 3/4 2 3 3 7-/2 7-/2 3 C8-2-M3-34 2 2 C8-2-M22-34 Series C8 C8-09-M40 contactor C8 Contactors Non-Reversing, Four Pole Contactors With DC Coil, Series C8 (Open type only) ➊➋➍➑ I e [] 40ºC Ratings for Switching C Motors (C2 / C3) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø Contact configuration main poles Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 4 0 C8-09C-M40-2 20 3 4 4 4 /2 -/2 2 2 5 5 3 C8-09C-M3-36 2 2 C8-09C-M22-36 4 0 C8-2C-M40-52 20 3 5.5 5.5 5.5 3/4 2 3 3 7-/2 7-/2 3 C8-2C-M3-67 2 2 C8-2C-M22-67 C Coil Codes ➊➌ C Coil Code Voltage Range 50 Hz 60 Hz 2 2V 2V 24Z 24V 24V 48Z 48V 48V 20 0V 20V 208 200V-220V 208V-220V 240 240V 240V 380 ➏ Use Coil Code 400 400 ➏ 400V 400V 480 440V 480V 575 ➐ Use Coil Code 600 600 ➐ 525V 600V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code DC Coil Codes ➊➌ DC Coil Code Voltage 2D 2V 24D 24V ➎ 0D 0V 25D 25V 220D 220V See Coil Codes on this page ➊ C8 not available without coil. Coils and contacts not replaceable. ➋ Select Coil Code from DC Coil Code table only. ➌ The coil codes shown are the most commonly stocked items. Contact your Sprecher + Schuh representative to determine if other voltages are available. ➍ No auxiliary contacts provided in the base of a C8. dd auxiliaries from page 2. ➎ Integrated diode surge suppressor coils available. Order coil code 24DD. Example: C8-09C-0-24D becomes C8-09C-0-24DD. dd $37 to list price. ➏ The European Community has agreed that 400V is the nominal voltage in lieu of 380V. Use this code when 380V is required. ➐ Use this code for 575V applications. ➑ See page 27 regarding mechanically linked contacts and mirror contact performance. 7

C8 Contactors Reversing, Three Pole Contactors With C Coil, Series CU8 (Open type only) ➊➋➑ I e [] 40ºC Ratings for Switching C Motors (C2 / C3 / C4) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø ➐ 3 Ø uxiliary Contacts per Contactor Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 20 3 4 4 4 /2 -/2 2 2 5 5 0 CU8-09-02- -LW 233 2 CU8-09-42- -PW 246 20 3 5.5 5.5 5.5 3/4 2 3 3 7-/2 7-/2 0 CU8-2-02- -LW 37 2 CU8-2-42- -PW 304 Miniature Contactors Reversing Series CU8 CU8 LW Includes: Mechanical interlock (CM8) Reversing, Three Pole Contactors With DC Coil, Series CU8 (Open type only) ➊➋➑ I e [] 40ºC Ratings for Switching C Motors (C2 / C3 / C4) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø ➐ 3 Ø uxiliary Contacts per Contactor Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 20 3 4 4 4 /2 -/2 2 2 5 5 0 CU8-09C-02- -LW 293 2 CU8-09C-42- -PW 306 20 3 5.5 5.5 5.5 3/4 2 3 3 7-/2 7-/2 0 CU8-2C-02- -LW 370 2 CU8-2C-42- -PW 383 CU8 PW Includes: Mechanical and electrical interlock (CM8) ➋ Reversing power and control wiring (using Wiring Kit Cat.# CUT8-PW) Top mount auxiliary contact block (Cat.# C8-P20 on the -42- models) C Coil Codes ➊➌ C Coil Code Voltage Range 50 Hz 60 Hz 2 2V 2V 24Z 24V 24V 48Z 48V 48V 20 0V 20V 208 200V-220V 208V-220V 240 240V 240V 380 ➎ Use Coil Code 400 400 ➎ 400V 400V 480 440V 480V 575 ➏ Use Coil Code 600 600 ➏ 525V 600V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code DC Coil Codes ➊➌ DC Coil Code Voltage 2D 2V 24D 24V ➍ 0D 0V 25D 25V 220D 220V See Coil Codes on this page ➊ C8 not available without coil. Coils and contacts not replaceable. ➋ Internal NC contacts on each contactor are used for electrical interlocking. ➌ The coil codes shown are the most commonly stocked items. Contact your Sprecher + Schuh representative to determine if other voltages are available. ➍ Integrated diode surge suppressor coils available. Order coil code 24DD. Example: CU8-09C-02-24D becomes CU8-09C-02-24DD. dd $74 to list price. ➎ The European Community has agreed that 400V is the nominal voltage in lieu of 380V. Use this code when 380V is required. ➏ Use this code for 575V applications. ➐ Does not apply to CU8...-PW. ➑ See page 27 regarding mechanically linked contacts and mirror contact performance. 8

Non-Reversing, Three Pole Starters With C Coil, Series CT8 (Open type only) ➊➐ I e [] 40ºC Ratings for Switching C Motors (C2 / C3 / C4) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø uxiliary Contacts per Contactor Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 20 3 4 4 4 /2 -/2 2 2 5 5 0 CT8-09-0- - 68 0 CT8-09-0- - 68 20 3 5.5 5.5 5.5 3/4 2 3 3 7-/2 7-/2 0 CT8-2-0- - 96 0 CT8-2-0- - 96 Miniature Starters, C & DC Coil Series CT8 C8 Contactors Non-Reversing, Three Pole Starters With DC Coil, Series CT8 (Open type only) ➊➋➐ I e [] 40ºC Ratings for Switching C Motors (C2 / C3 / C4) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø uxiliary Contacts per Contactor Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 20 3 4 4 4 /2 -/2 2 2 5 5 0 CT8-09C-0- - 9 0 CT8-09C-0- - 9 20 3 5.5 5.5 5.5 3/4 2 3 3 7-/2 7-/2 0 CT8-2C-0- - 229 0 CT8-2C-0- - 229 Representative model of a CT8-09 starter with the CT8 bimetallic overload relay NOTE: CT8 starters are priced to include Sprecher + Schuh s economical CT8 bimetallic overload relay. See 23 for selection. C Coil Codes ➊➌ C Coil Code Voltage Range 50 Hz 60 Hz 2 2V 2V 24Z 24V 24V 48Z 48V 48V 20 0V 20V 208 200V-220V 208V-220V 240 240V 240V 380 ➎ Use Coil Code 400 400 ➎ 400V 400V 480 440V 480V 575 ➏ Use Coil Code 600 600 ➏ 525V 600V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code Replace ( ) with O/L Relay Code DC Coil Codes ➊➌ DC Coil Code 2D 24D 0D 25D 220D Voltage 2V 24V ➍ 0V 25V 220V Coil Codes on this page O/L Relay Code on 23 ➊ C8 not available without coil. Coils and contacts not replaceable. ➋ Select Coil Code from DC Coil Code table only. ➌ The coil codes shown are the most commonly stocked items. Contact your Sprecher + Schuh representative to determine if other voltages are available. ➍ Integrated diode surge suppressor coils available. Order coil code 24DD. Example: CT8-09C-0-24D becomes CT8-09C-0-24DD. dd $37 to list price. ➎ The European Community has agreed that 400V is the nominal voltage in lieu of 380V. Use this code when 380V is required. ➏ Use this code for 575V applications. ➐ See page 27 regarding mechanically linked contacts and mirror contact performance. 9

C8 Contactors Reversing, Three Pole Starters With C Coil, Series CUT8 (Open type only) ➊➋➐ I e [] 40ºC Ratings for Switching C Motors (C2 / C3 / C4) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø Miniature Starters, C and DC Coil Reversing Series CUT8 uxiliary Contacts per Contactor Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 20 3 4 4 4 ~ ~ 2 2 5 5 0 CUT8-09-02- - -LW 329 2 CUT8-09-42- - -PW 342 20 3 5.5 5.5 5.5 ~ ~ 3 3 7-/2 7-/2 0 CUT8-2-02- - -LW 396 2 CUT8-2-42- - -PW 409 Reversing, Three Pole Starters With DC Coil, Series CUT8 (Open type only) ➊➋➐ I e [] 40ºC Ratings for Switching C Motors (C2 / C3 / C4) 3 Ø kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø uxiliary Contacts per Contactor Open Type 400V C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 20 3 4 4 4 ~ ~ 2 2 5 5 0 CUT8-09C-02- - -LW 44 2 CUT8-09C-42- - -PW 427 20 3 5.5 5.5 5.5 ~ ~ 3 3 7-/2 7-/2 0 CUT8-2C-02- - -LW 49 2 CUT8-2C-42- - -PW 504 CUT8 LW Includes: Mechanical interlock Utilizes CT8 bimetallic overload relay. Select code from page 23. CUT8 PW Includes: Mechanical and electrical interlock ➋ Utilizes CT8 bimetallic overload relay. Select code from page 23. Reversing power and control wiring (using Wiring Kit Cat.# CUT8-PW) Top mount auxiliary contact block (Cat.# C8-P20 on the -42- models) C Coil Codes ➊➌ C Coil Code Voltage Range 50 Hz 60 Hz 2 2V 2V 24Z 24V 24V 48Z 48V 48V 20 0V 20V 208 200V-220V 208V-220V 240 240V 240V 380 ➎ Use Coil Code 400 400 ➎ 400V 400V 480 440V 480V 575 ➏ Use Coil Code 600 600 ➏ 525V 600V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code Replace ( ) with O/L Relay Code DC Coil Codes ➊➌ DC Coil Code Voltage 2D 2V 24D 24V ➍ 0D 0V 25D 25V 220D 220V Coil Codes on this page O/L Relay Code on 23 ➊ C8 not available without coil. Coils and contacts not replaceable. ➋ NC contacts on each contactor are used for electrical interlocking. ➌ The coil codes shown are the most commonly stocked items. Contact your Sprecher + Schuh representative to determine if other voltages are available. ➍ Integrated diode surge suppressor coils available. Order coil code 24DD. Example: CUT8-09C-02-24D becomes CUT8-09C-02-24DD. dd $74 to list price. ➎ The European Community has agreed that 400V is the nominal voltage in lieu of 380V. Use this code when 380V is required. ➏ Use this code for 575V applications. ➐ See page 27 regarding mechanically linked contacts and mirror contact performance. 20

uxiliary Contact Blocks (2 & 4 Pole) ➊➋ uxiliary Contact Blocks NO NC Contact rrangement Catalog No. Price C8-P 24.6 0 2 C8-P02 24.6 uxiliary Contact Blocks NO NC ccessories - Field Installable C8 Miniature Contactors & Starters Contact rrangement Catalog No. Price CS8-PE 24.6 0 2 CS8-P02E 24.6 C8 Contactors 2-Pole 2 0 C8-P20 24.6 2-Pole 2 0 CS8-P20E 24.6 2 2 C8-P22 48.3 2 2 CS8-P22Z 48.3 Typical auxiliary contact block Typical auxiliary contact block 3 C8-P3 48.3 3 CS8-P3Z 48.3 3 C8-P3 48.3 3 CS8-P3E 48.3 0 4 C8-P04 48.3 0 4 CS8-P04E 48.3 4-Pole 4 0 C8-P40 48.3 4-Pole 4 0 CS8-P40E 48.3 Electronic Timer Module Description Function Connection Diagrams For use with Pkg Qty Catalog Number Price Each ~ Solid-State Timing Element 0 250V C or DC Includes 35mm Hat Rail adapter On-Delay 0. 3 s On-Delay 30 s S O/I K N 2 C8/CS8 all 0 CRZE8-3S CRZE8-30S 33 ➊ uxiliary contacts mirror contact performance per IEC 60947-4-. Contacts are bifurcated (H-bridge) with a minimum rating of 2m @ 5V. ➋ See page 27 regarding mechanically linked contacts and mirror contact performance. 2

ccessories - Field Installable C8 Miniature Contactors & Starters C8 Contactors Miscellaneous ccessories ccessory Description Catalog Number Price Surge Suppressor CR 8 - for limiting voltage spikes when switching off coil. Coil itself provides sufficient limitation at voltages over 240V. RC Link (Type CRC8 ) for C Control 24-48VC 0-280VC 380-480VC Diode Link (Type CRD8 ) for DC Control ➊ 2-250VDC (diode) Varistor Link (Type CRV8 ) for C/DC Control 2-55VC/2-77VDC 56-36VC/78-80VDC 37-277VC/8-250VDC Mechanical Interlock Kit - For interlocking of two adjacent contactor without additional space requirement in width attachable from the front (top) of contactor optional auxiliary contact blocks can be mounted on the top (does not interfere with mounting CR 8) CRC8-50 CRC8-280 CRC8-480 30.4 CRD8-250 30.4 CRV8-55 CRV8-36 CRV8-277 30.4 CM8 9.45 Wiring Kit - For connecting line, load and control wiring of a CU8 reversing contactor. works with CT8 Overloads CUT8-PW 2.4 Connection Modules - For KT7 motor circuit controller with a C8 contactor. KT7-25S-PEK2 63.7 Feeder Terminal for Compact Bus Bars - Supply of compact bus bars. For use with C8-09 and C8-2 34 mps max. C8-WT 38.9 Three-Phase Compact Bus Bars - For use with C8-09 and C8-2 Contactors with 45 mm spacing. (3 connections) 34 mps max. Three-Phase Compact Bus Bars - For use with C8-09 and C8-2 Contactors with 45 mm spacing. (4 connections) 34 mps max. C8-W453 47.5 C8-W454 53.2 ➊ C8 contactors with 24 VDC coils can be special ordered with integrated diodes (built-in) rather than applying CRD8 to the coil terminals. 22

CT8 Starters with CT8 Thermal Overload Relay For use with contactor... C8-09 mp Range Overload Relay Code ( ) Catalog Number (of Overload Relay used) Price dder or 3-Phase, uto/manual, Class 0 0.0 0.6 86 CT8-6 Standard 0.6...0.25 825 CT8-25 Standard 0.25...0.4 840 CT8-40 Standard 0.35...0.5 850 CT8-50 Standard 0.45...0.63 863 CT8-63 Standard 0.55...0.8 880 CT8-80 Standard 0.75...0 8B0 CT8-B0 Standard 0.90...3 8B3 CT8-B3 Standard.0...6 8B6 CT8-B6 Standard.4...2.0 8B20 CT8-B20 Standard.8...2.5 8B25 CT8-B25 Standard 2.3...3.2 8B32 CT8-B32 Standard 2.9...4.0 8B40 CT8-B40 Standard 3.5...4.8 8B48 CT8-B48 Standard 4.5...6.3 8B63 CT8-B63 Standard 5.5...7.5 8B75 CT8-B75 Standard C8-09 or 2 7.2...0 8C0 CT8-C0 Standard C8-2 9.0...2.5 8C2 CT8-C2 Standard Overload Relay Codes Series C8 Starters C8 Contactors Obsolete Contactors Cross Reference, Series C4 to Series C8 (Open Type Only) I [] e Ratings for Switching C Motors (C2 / C3 / C4) uxiliary Series C4 Series C8 kw (50 Hz) UL/CS HP (60 Hz) Contacts per Obsolete Replacement Ø 3 Ø Contactor 400V Catalog Catalog C-3 C- 230V 45V 500V 5V 230V 200V 230V 460V 575V NO NC Number Number 9 20 3 4 4 /2 -/2 2 2 5 5 0 C4-9-0 0 C4-9-0 ~ 20 3 4 4 /2 -/2 2 2 5 5 0 C8-09-0 0 C8-09-0 2 20 3 5.5 4 /2 2 3 3 7-/2 0 0 C4-2-0 0 C4-2-0 ~ 20 3 5.5 5.5 3/4 2 3 3 7-/2 7-/2 0 C8-2-0 0 C8-2-0 C4-9-0 Contactor 23

C8 Contactors Technical Information C8-09 C8-2 Rated Insulation Voltage U i to IEC947- [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240, 400, 45, 500, 690 DC [V] 24, 48, 0, 220, 440 Operating Frequency for C Loads [Hz] 50/60Hz Switching Motor Loads Standard IEC Ratings C-2, C-3, C-4 230V [].3.3 DOL & Reversing 240V [].3.3 50Hz@60 C 400V [] 8.5.5 45V [] 8.5.5 500V [] 6.8 9.2 690V [] 4.9 6.7 230V [kw] 3 3 240V [kw] 3 3 400V [kw] 4 5.5 45V [kw] 4 5.5 500V [kw] 4 5.5 690V [kw] 4 5.5 UL/CS 5V [] 9.8 3.8 DOL & Reversing 230V [] 0 2 60Hz 5V [HP] 0.5 0.75 230V [HP].5 2 200V [] 7.8 230V [] 6.8 9.6 460 V [] 7.6 3 575 V [] 6. 9 200 V [HP] 2 3 230 V [HP] 2 3 460 V [HP] 5 7.5 575 V [HP] 5 7.5 Maximum Operating Rate C2 [ops/ hour] 300 300 t 9 for C3; 20 for C2/4 C3 [ops/ hour] 600 600 Starting time t = 0.25s C4 [ops/ hour] 300 300 C4 (200,000 Op. Cycles) 230V [] 3.9 3.9 50Hz 240V [] 3.9 3.9 400V [] 3.6 3.6 45V [] 3.6 3.6 500V [] 3.2 3.2 230V [kw] 0.75 0.75 240V [kw] 0.75 0.75 400V [kw].5.5 45V [kw].5.5 500V [kw].5.5 Max. Operating Rate [ops/ hour] 250 250 Technical Information C8 Miniature Contactors C8-09 C8-2 Wye-Delta (Star Delta) 230V [] 20 20 50 Hz 240V [] 20 20 400V [] 5.5 5.5 45V [] 5.5 5.5 500V [] 2.4 2.4 690V [] 8.9 8.9 230V [kw] 5.5 5.5 240V [kw] 5.5 5.5 400V [kw] 7.5 0 45V [kw] 7.5 500V [kw] 7.5 7.5 690V [kw] 7.5 7.5 60 Hz 200V [Hp] 3 5 230V [Hp] 3 5 460V [Hp] 7.5 0 575V [Hp] 7.5 0 C- Load, 3 Switching mbient Temperature 40 C I e [] 20 20 230V [kw] 8 8 240V [kw] 8.3 8.3 400V [kw] 4 4 45V [kw] 4 4 500V [kw] 7 7 690V [kw] 24 24 mbient Temperature 60 C I e [] 6 6 230V [kw] 6.4 6.4 240V [kw] 6.7 6.7 400V [kw] 45V [kw] 2 2 500V [kw] 4 4 690V [kw] 9 9 Continuous Current (UL/CS) General Purpose Rating (40 C) Open [] 5 8 Enclosed [] 5 8 Lighting Loads Gas Dischrg.Lamps-C-5a, 220 240VC (40ºC) Single compensated Max. capacitance at prospective short circuit current available at the contactor Enclosed [] 8 8 Open [] 5 5 0k [mf] 750 750 20k [mf] 400 400 50k [mf] ~ ~ Incandescent Lamps - C-5b Electrical endurance~00,000 operations 230/240V [] 9.0 9.0 24

Electrical Data C8-09 C8-2 Switching power transformers C-6a (50Hz) Inrush Rated transformer current = η η = 30 230V [] 5.4 5.4 240V [] 5.4 5.4 400V [] 4. 5.4 45V [] 4. 5.4 500V [] 3.2 3.2 230VC [kv] 2 2 240VC [kv] 2 2 400VC [kv] 2.8 3.4 45VC [kv] 2.8 3.4 500VC [kv] 2.8 3.4 690VC [kv] 4 5 DC Ratings DC- Rating at 60 C Pole 24VDC [] 9 9 48/60VDC [] 6/.5 6/.5 0VDC [] 220VDC [] 0.3 0.3 440VDC [] 0. 0. 2 Pole in Series 24VDC [] 9 9 48/60VDC [] 8 8 0VDC [] 6 6 220VDC [].2.2 440VDC [] 0.3 0.3 3 Pole in Series 24VDC [] 9 9 48VDC [] 9 9 0VDC [] 9 9 220VDC [] 4 4 440VDC [] 0.6 0.6 Shunt-wound Motors Starting, reverse current braking, reversing stepping DC-3, 60 C 24V [] 9 9 3 Poles in series 48/60V [] 6 6 0V [] 3 3 220V [].2.2 440V [] 0.2 0.2 Series-wound Motors Starting, reverse current braking, reversing stepping DC-5, 60 C 24V [] 9 9 3 poles in series 48/60V [] 3 3 0V [] 220V [] 0. 0. 440V [] ~ ~ Short Time Withstand-I CW, 60 C 0s [] 96 96 Coil Data Technical Information C8 Miniature Contactors Short Circuit Coordination (Max. Fuse or Circuit Breaker Rating) C8-09 C8-2 50 k Max. DIN fuse gg per IEC 60947-4- (Contactor and Fuse only) vailable Fault Current Type Coordination (690V) max. [] 35 35 Type 2 Coordination (690V) max. [] 20 20 Class K5 and RK5 fuses ➊ max. [] 40 40 Resistance and Watt Loss l e C3 Resistance per power pole [mw] 2.2 2.2 Watt Loss - 3 power poles @400V [W] 0.9 0.9 Coil and C @400V, warm [W] 2.7 2.7 3 power poles DC, warm [W] 3.5 3.5 C8-09 C8-2 Voltage Range C: 50Hz, 60Hz, 50/60 Hz Pickup [x Us] 0.85... Dropout [x Us] 0.2 0.75 DC Pickup [x Us] 0.80. 9, 2, 24, 0V DC: 0.7.25 Dropout [x Us] 0...0.75 Coil Consumption C: 50Hz, 60Hz, 50/60 Hz Pickup [V] 35 Hold-in [V/W] 5/.8 DC Pickup [W] cold 3.0, warm 2.6 Hold-in [W] cold 3.0, warm 2.6 Operating Times C: 50Hz, 60Hz, 50/60 Hz Pickup [ms] 5...40 Dropout [ms] 5...33 with RC Suppressor Dropout [ms] 5...28 DC Pickup [ms] 8...40 Dropout [ms] 6...2 with Integ. Suppression Dropout [ms] 8...2 with external diode Suppression Dropout [ms] 35...50 Minimal changeover time for reversing [ms] >50 C8 Contactors ➊ UL listed combination. 25

Technical Information C8 Miniature Contactors C8 Contactors Mechanical Data Service Life C8-09 Mechanical C/DC [Mil.Op.] 5 Electrical C-3(400V) [Mil.Op.] 0.7 Reversing combination, mechanical, electrical [Mil.Op.] 0.7 C8-2 Environmental and General Specifications mbient Temperature ➋ Storage -55...+80 C (-67...76 F) Operation -25...+60 C (-3...40 F) (40 C per UL) Conditioned 5% current -25...+70 C (-3...58 F) reduction after C- at >60 C Shipping Weights C-C8 [kg] 0.6 [Lbs] 0.35 C-CU8 [kg] 0.35 [Lbs] 0.77 DC-C8 [kg] 0.20 [Lbs] 0.44 DC-CU8 [kg] 0.43 [Lbs] 0.9 ltitude at installed site 2000 meters above sea level per IEC 60947-4 Resistance to Corrosion / Humidity Damp-alternating climate: cyclic to IEC 68-2, 56 cycles. Dry Heat: IEC 68-2, +00 C (22 F), relative humidity <50%, 7 days. Damp tropical: IEC 68-2, +40 C (04 F), relative humidity <92%, 56 days. Shock Resistance IEC 68-2/EN 60068 Vibration Resistance IEC 68-2/EN 60068 Terminations - Screw Type Terminals Main contacts and uxiliary contacts Operating Position Standards Refer to Dimension Page 29 IEC/EN 60947-, -4-, -5-, -5-4; UL 508; CS 22.2. No. 4 Terminal Type Combination Screw Head: Cross, Slotted, Pozidrive Fine wire [mm stranded 2 ] 0.75...2.5 w/ ferrule 2 wires [mm 2 ] 0.75...2.5 Solid or coarse stranded wire 2 wires [mm 2 ] [mm 2 ] 4...2.5 + 4 [WG] 8 2 Torque Requirement [Nm].2 [Lb-in] 0.6 pprovals CE, culus, CCC High Fault Short Circuit Ratings per UL508 and CS 22.2 No.4 CT8 Overload Cat. No. Contactor Cat. No. Max. starter FLC () Max. available fault current (k) Fuse Ratings Max. voltage (V) UL Class J, CC, CS HRCI-J fuse max. () UL Listed Circuit Breaker Ratings ➊ Short Circuit Rating (k) Max. voltage (V) Max. CB Rating () Group Installation ➊ Max. CB rating () 6 40 50 63 2 80 B0 3 B3 4 B6 5 B20 C8-09 0 50 600 8 5 600 5 30 B25 0 B32 2 B40 B48 5 B63 20 B75 25 C0 C8-09 2 35 C2 C8-2 3.8 50 ➊ Group installation ratings can be applied when used with C8 Compact Bus Bars (see 22) in a minimum,52 cu. in. enclosure with two latches. ➋ mbient is the temperature outside the enclosure. 26

uxiliary Contacts Technical Information C8 Miniature Contactors Built-in uxiliary Contacts dd-on uxiliary Contacts Current Switching C-2 I th at 40 C [] 0 0 at 60 C [] 6 6 C-5, switching electromagnetic loads at: [V] 24 20 240 400 480 500 600 690 24 20 240 400 480 500 600 690 [] 6 6 3.8.5.4.2 3 3 2.2 0.6 0.6 DC-3, switching DC electromagnets at: [V] 24 48 0 25 220 250 400 440 600 24 48 0 25 220 250 400 440 600 [] 2.8.2 0.55 0.55 0.27 0.27 0.5 0.5 0.0 2.3 0.55 0.55 0.27 0.27 0.5 0.5 0.0 DC-2, L/R< ms resistive loads at: [V] 24 48 0 25 220 250 400 440 [] 6 4 0.6 0.6 0.2 0.2 0.08 0.08 DC-4, L/R< 5 ms inductive loads [V] 24 48 0 25 220 250 400 440 with economy resistor in series at: [] 4 2.5 0.4 0.4 0.2 0.2 0.05 0.05 Low Level Signal Switching Contact design X-stamped H-bridge, bi-furcated Minimum switching recommendation [V] 7V 5V [m] 0m 2m Short-Circuit Protection - gg Fuse Type 2 Coordination [] 0 0 Load carrying capacity per UL/CS Rated Voltage C [V] 600 max. 600 max. Continuous Rating 40 C [] 0 general purpose 0 general purpose Switching Capacity C Heavy pilot duty (600) Heavy pilot duty (B600) Rated Voltage DC [V] 600 max. 600 max. Switching Capacity DC Standard pilot duty (Q600) Standard pilot duty (Q600) Mechanically Linked Contacts IEC 60947-5-, nnex L Yes No Mirror Contacts IEC 60947-4, nnex F Yes Yes C8 Contactors Contact Ratings (Per NEM/UL 600, B600 & Q600) Standard 600 B600 Q600 Circuit Voltage 20C 240C 480C 600C 20C 240C 480C 600C 25DC 250DC 30-600DC Make (mps/v) 60/7200V 30/7200V 5/7200V 2/7200V 30/3600V 5/3600V 7.5/3600V 6/3600V 0.55/69V 0.27/69V 0./69V Break (mps/v) 60/720V 30/720V 5/720V 2/720V 3.0/360V.5/360V 0.75/360V 0.60/360V 0.55/69V 0.27/69V 0./69V Continuous mps 0 0 2.5 Mechanically Linked Contacts and Mirror Contact Performance Type Coil dd-on uxiliary Contact Conforms to IEC Status C or DC None 60947-5- Mechanically linked within the base contactor DC Yes 60947-5- Mechanically linked within the base contactor and with add-on C8 auxiliary contacts C Yes 60947-4- Mechanically linked within the base contactor and mirror contact performance with add-on auxiliary contacts Definitions Mechanically linked contacts (IEC 60947-5- nnex L): N.C. uxiliary Contact will not re-close if a N.O. power pole welds. N.O. Power Pole or uxiliary Contact will not close if N.C. contact welds. The term Positive Guided contacts is the same as mechanically linked. Mirror Contacts (IEC 60947-4- nnex F): N.C. uxiliary Contact will not be in closed position if a N.O. power pole welds. 27

Technical Information C8 Miniature Contactors Life Load Curves Life-Load Curves C8 Contactors Locate the Rated Operational Current (l e ) along the bottom of the chart and follow the graph lines up to the intersection of the appropriate contactor s life-load curve. Read the estimated contact life along the vertical axis. C-, C3 (400...460V C) 0 C8-2 C8-9 C- Non- or slightly inductive loads, resistance furnaces; C-3 Switching of squirrel-cage motors while starting Ue = 400...45 VC C -,C -3 Contact Life (Millions of Operations) 0. Instructions on How to read Life Curves can be found on page 8 (C - ) 0.0 0 00 Rated operational current Ie C-3 [] (Dashed curves ---- C- only, open) C-4 (400...460V C) C-4 Stepping of squirrel-cage motors Ue = 400...45 VC 0 C8-9 & 2 C4 Contact Life (Millions of Operations) 0. 0.0 0. 0 Rated operational current Ie [] NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 60947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 28

44.9 (-25/32) 35 (-25/64) Dimensions C8 Miniature Contactors Series C8 & Series CU8 (Contactors & Reversing Contactors) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 78.7 (3-7/64) 49 (-5/6) 4 (5/32) 35.2 (-25/64) Mounting Position with ccessories 25 25 90 90 C8 Contactors 50 (-3/32) (-5/6) (4-/4) 08.2 56 (2-3/64) 54 (2-/8) 2 (5/32)* * Minimum distance to grounded parts or walls 49.2 36.9 (-29/64) 63.5 (2-/2) Reversing Contactors & ccessories Contactor with... Dim. [mm] Dim. [inches] reversing with mechanical interlock 89.8 3.53 with aux. contact block 78.7 3. with timer on contactor 8.7 3.25 at side of contactor 66.9 2.63 with neutral terminal at side of contactor 64.9 2.56 with protection element with nameplate 5 2 29

C7 Contactors Series C7 Contactors Rugged, space saving and modular Sprecher + Schuh s contactor for applications up to 75HP @ 460V Over 00 years of design experience has produced Sprecher + Schuh s seventh generation contactor line. The C7 represents the most modern and flexible power contactor available today, meeting the highest industrial application requirements. Big performance in a small package wide selection of contactors in four frame sizes covers the entire C7 horsepower range (up to 75HP @ 460/575V). Six of the contactors are only 45mm wide, an extremely small footprint for such rugged performance. number of design features account for this efficiency, including high contact pressure and bouncefree contacts, allowing the devices to handle the high starting currents typical of modern motors. Type and Type 2 Coordination Whether you re designing motor circuits for use in North merica, Europe or any other part of the world, all C7 contactors have been designed and tested with respect to Type and Type 2 short circuit coordination. Find out more in the C7 Technical Information section in this chapter. dvanced safety and reliability features The entire C7 line features mechanically linked contacts, sometimes referred to as positively guided contacts or force guided contacts. If a main power pole welds, adequate clearances exist ( 0.3mm) to ensure that the auxiliary contacts do not change state when coil power is removed and the device tries to open. This is a requirement in safety circuits per IEC 60947-5-. Reliability is further assured by crossstamped auxiliary contacts, which provide multi-point reliability in low current, low voltage applications. dvantages of Electronic DC Coil C7-9E through C7-55E are provided with DC coils that dramatically decrease wattage consumption during pull-in. This allows the use of smaller power supplies. The electronic DC coil design allows the height of the contactor to be the same size as the C version. Larger C7 contactors are available with a two-winding DC coil that also reduces the size of the contactor as well as the hold-in values. 45mm ( 3/4 ) 45mm ( 3/4 ) 54mm ( 2 /8 ) 72mm ( 2 3/6 ) 9 2 6 23 30 37 43 55 60 72 85 97 30

Modular accessories are common to all devices Reversible coil provides total flexibility ll accessories are interchangeable among all C7 contactors and CS7 control relays. This minimizes inventory requirements and maximizes flexibility. Top and side mount auxiliary contacts are available depending on your application. mechanical interlock with two built-in NC auxiliaries also provides electrical interlocking if desired. Pneumatic and electronic timers, surge suppressors and electronic interface modules provide solutions for even the most complex applications. When shipped, both coil connections are normally located at the top of the contactor in preparation for mounting an overload relay at the bottom. For multi-starter panels, however, the coil can be reversed, which provides space to close-couple a KT7 Motor Circuit Controller on the top of the contactor. C7 contactors can either be ordered with the coil reversed or may be easily reversed in the field. Dual power terminals speed wiring Top mounted coil Bottom mounted coil Reversible coils are standard on all C7 contactors C7 Contactors C7-30 through 97 contactors are designed with two power terminals for all three poles. This simplifies power wiring of interconnected contactors in reversing, reduced voltage and twospeed applications. Preformed power wiring connectors are also available for virtually instantaneous wiring in these labor intensive applications. Simplified wiring means less labor and less cost. Two power terminals on each pole Dual power terminals assure hassle-free wiring in complex control schemes Special use contactors for specialized applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In all cases, these devices are UL and CS approved for these specialized uses. Lighting contactors The CL7 contactor can be used to control a wide variety of lighting loads. These contactors are well suited to handle the high inrush currents typical of this application as well as other non-motor (resistive) loads. Both mechanically held and electrically held models are available for lighting load applications up to 20, 30 and 60. CL7 Lighting Contactor CNX Special Purpose Contactor CN7 NEM labeled contactor NEM Labeled Contactors CN7 contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are NEM compliant and are labeled accordingly. Special purpose contactors CNX contactors are standard C7 contactors that have been tested, approved and labeled by UL for heating ventilation and air conditioning (HVC) applications. Sprecher + Schuh s C7 line includes contactors designed and labeled for specific industrial applications 3

C7 Contactors Non-Reversing, Three Pole Contactors With C Coil, Series C7 (Open type only) ➊ I e [] ➊ Coil Codes ➋ Ratings for Switching C Motors (C2 / C3 / C4) kw (50 Hz) UL/CS HP (60 Hz) Ø 3 Ø uxiliary Contacts per Contactor Open Type C-3 C- 230V 400V / 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 9 32 3 4 4 4 /2 /2 2 2 5 7-/2 0 C7-9-0-0 C7-9-0-4 2 32 4 5.5 5.5 5.5 /2 2 3 3 7-/2 0 0 C7-2-0-0 C7-2-0-47 6 32 5.5 7.5 7.5 7.5 3 5 5 0 5 0 C7-6-0-0 C7-6-0-65 23 32 7.5 3 0 2 3 5 7-/2 5 5 0 C7-23-0-0 C7-23-0-85 0 0 C7-30-00-26 30 65 0 5 5 5 2 5 7-/2 0 20 25 0 C7-30-0-236 0 C7-30-0-236 37 65 8.5/ 20 20 8.5 3 5 0 0 25 30 43 85 3 22 25 22 3 7-/2 0 5 30 30 55 85 5 30 30 22 5 0 5 20 40 40 60 00 8.5 32 37 32 5 0 5 20 40 50 72 00 22 40 45 40 5 5 20 25 50 60 85 00 25 45 55 45 7-/2 5 25 30 60 60 97 30 30 55 55 55 0 20 30 30 75 75 C Coil Code Voltage Range 50 Hz 60 Hz 24Z 24V 24V 20 0V 20V 208 ~ 208V 220W 200V-220V 208V-240V 240 220V 240V 277 240V 277V 380 380V-400V 440V 480 440V 480V 600 550v 600V 0 0 C7-37-00-255 0 C7-37-0-275 0 C7-37-0-275 0 0 C7-43-00-273 0 C7-43-0-293 0 C7-43-0-293 0 0 C7-55-00-32 0 C7-55-0-332 0 C7-55-0-332 0 0 C7-60-00-337 0 C7-60-0-357 0 C7-60-0-357 0 0 C7-72-00-389 0 C7-72-0-409 0 C7-72-0-409 0 0 C7-85-00-48 0 C7-85-0-50 0 C7-85-0-50 0 0 C7-97-00-524 0 C7-97-0-544 0 C7-97-0-544 Coil Terminal Position ➌ ll C7 contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. C7 coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering C7 contactors with reversed coils. Contactors - C Coil Three Pole - Series C7 C7-9-0 contactor C7-55-00 contactor C7-97-00 contactor ll C7 contactors come with reversible coils. Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ C Resistive Ratings and UL/CS Continuous Current Ratings may be increased by the use of Lug Kits or Paralleling Links. See C7 ccessories section for applicable information. ➋ Other voltages available, see page 56. ➌ For coil terminals on the load side (bottom) add a U in front of the coil code. For example: C7-23-0-20 becomes C7-23-0-U20. 32

Non-Reversing, Four Pole Contactors With C Coil, Series C7 (Open type only) Ratings for Switching C Motors (C2 / C3 / C4) Contact Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Configuration, Ø 3 Ø Main Pole C-3 C- 230V 400V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number Price 4 0 C7-9-M40-4 9 32 3 4 4 4 /2 /2 2 2 5 7-/2 3 C7-9-M3-29 2 2 C7-9-M22-29 4 0 C7-2-M40-47 2 32 4 5.5 5.5 5.5 /2 2 3 3 7-/2 0 3 C7-2-M3-62 2 2 C7-2-M22-62 4 0 C7-6-M40-65 6 32 5.5 7.5 7.5 7.5 3 5 5 0 5 3 C7-6-M3-80 2 2 C7-6-M22-80 4 0 C7-23-M40-85 23 32 7.5 3 0 2 3 5 7-/2 5 5 3 C7-23-M3-200 2 2 C7-23-M22-200 37 75 8.5 20 8.5 3 5 0 0 25 30 4 0 C7-40-M40-369 37 75 8.5/20 8.5 7.5 3 5 0 0 25 5 2 2 C7-40-M22-369 85 30 25 45 55 45 7-/2 5 25 30 60 50 4 0 C7-90-M40-629 85 30 25 45 55 8.5 7-/2 5 25 30 50 20 2 2 C7-90-M22-629 Contactors - C Coil Four Pole - Series C7 C7-23-M22-20 contactor C7 Contactors Coil Codes ➊ C Coil Code Voltage Range 50 Hz 60 Hz 24Z 24V 24V 20 0V 20V 208 ~ 208V 220W 200V-220V 208V-240V 240 220V 240V 277 240V 277V 380 380V-400V 440V 480 440V 480V 600 550V 600V Coil Terminal Position ➋ ll C7 contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. C7 coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering C7 contactors with reversed coils. ll C7 contactors come with reversible coils. Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Other voltages available, see page 56. ➋ For coil terminals on the load side (bottom) add a U in front of the coil code. For example: C7-23-M40-20 becomes C7-23-M40-U20. 33

C7 Contactors Contactors - Low Consumption Electronic DC Coil Non-Reversing, Three Pole Contactors With Electronic DC Coil, Series C7 (Open type only) ➊➋➌ Ratings for Switching C Motors (C2 / C3 / C4) Open Type I e [] uxiliary kw (50 Hz) UL/CS HP (60 Hz) Contacts per ➊ Contactor Ø 3 Ø 400V/ Catalog C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Number 9 32 3 4 4 4 /2 /2 2 2 5 7-/2 2 32 4 5.5 5.5 5.5 /2 2 3 3 7-/2 0 6 32 5.5 7.5 7.5 7.5 3 5 5 0 5 23 32 7.5 3 0 2 3 5 7-/2 5 5 30 65 0 5 5 5 2 5 7-/2 0 20 25 37 65 8.5/ 20 20 8.5 3 5 0 0 25 30 43 85 3 22 25 22 3 7-/2 0 5 30 30 55 85 5 30 30 22 5 0 5 20 40 40 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C7-9E-0- C7-9E-0- C7-2E-0- C7-2E-0- C7-6E-0- C7-6E-0- C7-23E-0- C7-23E-0- C7-30E-00- C7-30E-0- C7-30E-0- C7-37E-00- C7-37E-0- C7-37E-0- C7-43E-00- C7-43E-0- C7-43E-0- C7-55E-00- C7-55E-0- C7-55E-0- Price 67 207 228 248 29 3 3 344 364 364 397 47 47 433 453 453 Three Pole - Series C7 C7-6E-0-0E contactor ➍ C7-23E-0-24E contactor Description Low Consumption Electronic DC coils have extremely low inrush which allows the use of smaller power supplies. C7-9E 55E has internal surge suppression. See page 69 for more information. This new design results in: Lighter, lower depth More energy efficient contactors Easier wiring Uniform panel appearance. pplications Direct control from PLC: The low power consumption contactor designed to control motors and other loads is especially aligned to the specific requirement of electronic control circuits. The low power consumption of.7 allows direct control through PLC s without the need for interposing relays. Power dissipation is greatly reduced limiting the heat effect in control panels. C7-55E-00-24E contactor Coil Codes ➋➍ DC Coil Codes Voltage 2E 2V 24E 24V 36E ➎ 36-48V 48E ➎ 48-72V 0E ➎ 0-25V 220E ➎ 220-250V Coil Terminal Position ➏ ll C7 contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. C7 coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering C7 contactors with reversed coils. ll C7 contactors come with reversible coils. (48V DC shown) ➊ C Resistive Ratings and UL/CS Continuous Current Ratings may be increased by the use of Lug Kits or Paralleling Links. See C7 ccessories section for applicable information. ➋ C7-9E 55E with electronic coils are not interchangeable with non-electronic DC or C coils. ➌ See page 47-48 for limitations on adding auxiliaries to Electronic DC Coil contacts. ➍ Voltages of 36V DC and greater are supplied with backpack module standard. See page 86. ➎ Not applicable with Electronic Timer accessories (CRZ_7). ➏ For coil terminals on the load side (bottom) add a U in front of the coil code. For example: C7-23E-0-24E becomes C7-23E-0-U24E. 34

Contactors - Low Consumption Electronic DC Coil Non-Reversing, Four Pole Contactors With Electronic DC Coil, Series C7 (Open type only) ➊➋ Ratings for Switching C Motors (C2 / C3 / C4) Contact Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Configuration, Ø 3 Ø Main Pole 400V C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number 9 32 3 4 4 4 /2 /2 2 2 5 7-/2 2 32 4 5.5 5.5 5.5 /2 2 3 3 7-/2 0 4 3 2 4 3 2 0 2 0 2 C7-9E-M40- C7-9E-M3- C7-9E-M22- C7-2E-M40- C7-2E-M3- C7-2E-M22- Price 67 82 82 207 222 222 Four Pole - Series C7 C7-23E-M22-24E contactor C7 Contactors 6 32 5.5 7.5 7.5 7.5 3 5 5 0 5 4 3 2 0 2 C7-6E-M40- C7-6E-M3- C7-6E-M22-228 243 243 23 32 7.5 3 0 2 3 5 7-/2 5 5 4 3 2 0 2 C7-23E-M40- C7-23E-M3- C7-23E-M22-37 75 8.5 20 8.5 3 5 0 0 25 30 4 0 C7-40E-M40-458 37 75 8.5/20 8.5 7.5 3 5 0 0 25 5 2 2 C7-40E-M22-458 248 263 263 Description Low Consumption Electronic DC coils have extremely low inrush which allows the use of smaller power supplies. C7-9E 55E have internal surge suppression. See page 69 for more information. This design results in: Lighter, lower depth More energy efficient contactors Easier wiring Uniform panel appearance pplications Direct control from PLC: The low power consumption contactor designed to control motors and other loads is especially aligned to the specific requirement of electronic control circuits. The low power consumption of.7 allows direct control through PLC s without the need for interposing relays. Power dissipation is greatly reduced limiting the heat effect in control panels. Coil Codes ➊➌ DC Coil Codes Voltage 2E 2V 24E 24V 36E ➍ 36-48V 48E ➍ 48-72V 0E ➍ 0-25V 220E ➍ 220-250V Coil Terminal Position ➎ ll C7 contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. C7 coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering C7 contactors with reversed coils. ll C7 contactors come with reversible coils. (48V DC shown) ➊ C7-9E 55E with electronic coils are not interchangeable with non-electronic DC or C coils ➋ See pages 47-48 for limitations on adding auxiliaries to Electronic DC Coil contacts. ➌ Voltages of 36V DC and greater are supplied with backpack module standard. See page 86. ➍ Not applicable with Electronic Timer accessories (CRZ_7). ➎ For coil terminals on the load side (bottom) add a U in front of the coil code. For example: C7-23E-M40-24E becomes C7-23E-M40-U24E. 35

C7 Contactors Contactors - Two Winding DC Coil Non-Reversing, Three Pole Contactors With Two Winding DC Coil, Series C7 (Open type only) ➊ Ratings for Switching C Motors (C2 / C3 / C4) uxiliary Open Type Contacts per I e [] kw (50 Hz) UL/CS HP (60 Hz) Contactor 400V/ Ø 3 Ø ➊ C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number 60 00 8.5 32 37 32 5 0 5 20 40 50 72 00 22 40 45 40 5 5 20 25 50 60 85 00 25 45 55 45 7-/2 5 25 30 60 60 97 30 30 55 55 55 0 20 30 30 75 75 Three & Four Pole - Series C7 Price 0 0 C7-60D-00-456 0 C7-60D-0-476 0 C7-60D-0-476 0 0 C7-72D-00-508 0 C7-72D-0-528 0 C7-72D-0-528 0 0 C7-85D-00-600 0 C7-85D-0-620 0 C7-85D-0-620 0 0 C7-97D-00-687 0 C7-97D-0-707 0 C7-97D-0-707 C7-60D Contactor Description: Contactors with two winding DC coils have very low hold-in values and share the same dimensions with C contactors. See page 57 for more information. See page 87 for dimensional information. Non-Reversing, Four Pole Contactors With Two Winding DC Coil, Series C7 (Open type only) ➊ Ratings for Switching C Motors (C2 / C3 / C4) Contact Configuration Main Pole uxiliary Contacts per Contactor I e [] kw (50 Hz) UL/CS HP (60 Hz) 45V Ø 3 Ø C-3 C- 230V 400V 500V 690V 5V 230V 200V 230V 460V 575V NO NC NO NC Open Type Catalog Number 85 30 25 45 55 45 7-/2 5 25 30 60 50 4 0 0 0 C7-90D-M40-746 85 30 25 45 55 8.5 7-/2 5 25 30 50 20 2 2 0 0 C7-90D-M22-746 Price Coil Codes ➋➌➍ DC Coil Code 24DD 0DD Voltage 24V 0V Ordering Instruct ions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ C7-60D C7-97D have an internal auxiliary contact to transition from the start winding to the run winding. ➋ Coils include an integrated diode surge suppressor. ➌ Other coil voltages are available, see page 57. Contact your Sprecher + Schuh Sales Representative to determine which coil voltages may be stocked. ➍ The coil codes shown are the most commonly stocked items. Contact your Sprecher + Schuh representative to determine if other voltages, i.e.., 2DD, 48DD, 220DD are on-hand or can be specially ordered in quantities. 36

Reversing, Three Pole Contactors With C Coil, Series CU7 (Open type only) Ratings for Switching C Motors (C2 / C3 / C4) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per Ø 3 Ø Contactor C-3 C- 230V 400V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC ➌ Catalog Number 9 32 3 4 4 4 /2 /2 2 2 5 7-/2 CU7-9-22-32 Contactors, C Coil Reversing Three Pole - Series CU7 Price C7 Contactors 2 32 4 5.5 5.5 5.5 /2 2 3 3 7-/2 0 CU7-2-22-388 CU7-9-22-20 reversing contactor 6 32 5.5 7.5 7.5 7.5 3 5 5 0 5 CU7-6-22-428 23 32 7.5 3 0 2 3 5 7-/2 5 5 CU7-23-22-466 30 65 0 5 5 5 2 5 7-/2 0 20 25 37 65 8.5/ 20 20 8.5 3 5 0 0 25 30 43 85 3 22 25 22 3 7-/2 0 5 30 30 55 85 5 30 30 22 5 0 5 20 40 40 60 00 8.5 32 37 32 5 0 5 20 40 50 72 00 22 40 45 40 5 5 20 25 50 60 85 00 25 45 55 45 7-/2 5 25 30 60 60 97 30 30 55 55 55 0 20 30 30 75 75 0 CU7-30-02-528 ➍ CU7-30-22-567 0 CU7-37-02-608 ➍ CU7-37-22-647 0 CU7-43-02-673 ➍ CU7-43-22-72 0 CU7-55-02-746 ➍ CU7-55-22-785 0 CU7-60-02-853 ➍ CU7-60-22-892 0 CU7-72-02-967 ➍ CU7-72-22-00 0 CU7-85-02-50 ➍ CU7-85-22-90 0 CU7-97-02-580 ➍ CU7-97-22-620 CU7-43-22-20 reversing contactor Includes: Line side coil terminations Mechanical and electrical Interlock ➌ Reversing power wiring ➊ (using Power Wiring Kit Cat.# CUT7-PW ) Control wiring available; see footnote ➋ Coil Codes ➎ C Coil Voltage Range Code 50 Hz 60 Hz 24Z 24V 24V 20 0V 20V 208 ~ 208V 220W 200V-220V 208V - 240V 240 220V 240V 277 240V 277V 380 380V-400V 440V 480 440V 480V 600 550V 600V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code ➊ For -LW Option Deduct the following from List Price CU7-9 23 0 CU7-30 37 2 CU7-43 55 22 ➋ For -CW Option dd the following to List Price CU7-9 97 20 See Coil Codes on this page. ➊ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example: CU7-9-22- becomes CU7-9-22- -LW. CU7-60 97 not available without power wiring. ➋ For control wiring, add suffix -CW to catalog number. Example: CU7-9-22- becomes CU7-9-22- -CW. ➌ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-02) and are used to electrically interlock the contactors. ➍ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➎ Other voltages available, see page 56. 37

C7 Contactors Contactors, Low Consumption Electronic DC Coil Reversing Reversing, Three Pole Contactors With Electronic DC Coil, Series CU7 (Open type only) ➎➏ Ratings for Switching C Motors (C2 / C3 / C4) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per Ø 3 Ø Contactor 400V C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC ➌ Catalog Number 9 32 3 4 4 4 /2 /2 2 2 5 7-/2 CU7-9E-22-426 Price Three Pole - Series CU7 2 32 4 5.5 5.5 5.5 /2 2 3 3 7-/2 0 CU7-2E-22-504 CU7-9E-22-24E Reversing contactor 6 32 5.5 7.5 7.5 7.5 3 5 5 0 5 CU7-6E-22-546 23 32 7.5 3 0 2 3 5 7-/2 5 5 CU7-23E-22-592 30 65 0 5 5 5 2 5 7-/2 0 20 25 37 65 8.5/ 20 20 8.5 3 5 0 0 25 30 43 85 3 22 25 22 3 7-/2 0 5 30 30 55 85 5 30 30 22 5 0 5 20 40 40 Description Low Consumption Electronic DC coils have extremely low inrush which allows the use of smaller power supplies. C7-9E 55E have internal surge suppression. See page 69 for more information. This new design results in: Lighter, lower depth More energy efficient contactors Easier wiring Uniform panel appearance 0 CU7-30E-02-680 ➍ CU7-30E-22-79 0 CU7-37E-02-85 ➍ CU7-37E-22-890 0 CU7-43E-02-9 ➍ CU7-43E-22-950 0 CU7-55E-02-98 ➍ CU7-55E-22-020 pplications Direct control from PLC: The low power consumption contactor designed to control motors and other loads is especially aligned to the specific requirement of electronic control circuits. The low power consumption of.7 allows direct control through PLC s without the need for interposing relays. Power dissipation is greatly reduced limiting the heat effect in control panels. CU7-37E-22-24E Reversing contactor Includes: Line side coil terminations Mechanical and electrical Interlock ➌ Reversing power wiring ➊ (using Power Wiring Kit Cat.# CUT7-PW ) Control wiring available; see footnote ➋ CU7-9E 55E has internal surge suppression. Coil Codes ➏➐ DC Coil Codes Voltage 2E 2V 24E 24V 36E ➑ 36-48V 48E ➑ 48-72V 0E ➑ 0-25V 220E ➑ 220-250V ➊ For -LW Option Deduct the following from List Price CU7-9E 23E 0 CU7-30E 37E 2 CU7-43E 55E 22 ➋ For -CW Option dd the following to List Price CU7-9E 55E 20 ➊ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example CU7-9E-22-24E becomes CU7-9E-22-24E-LW. ➋ For control wiring, add suffix -CW to catalog number. For example: CU7-9E-22-24E becomes CU7-9E-22-24E-CW. ➌ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-02) and are used to electrically interlock the contactors. ➍ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➎ C7-9E 55E with electronic coils are not interchangeable with non-electronic DC or C coils. ➏ See pages 47-48 for limitations. on adding auxiliaries to Electronic DC Coil contacts. ➐ Voltages of 36V DC and greater are supplied with backpack module standard. See page 86. ➑ Not applicable with Electronic Timer accessories (CRZ_7). 38

Reversing, Three Pole Contactors With DC Coil, Series CU7 (Open type only) Ratings for Switching C Motors (C2 / C3 / C4) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per Ø 3 Ø Contactor 400V Catalog C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC ➋ Number Price 60 00 8.5 32 37 32 5 0 5 20 40 50 0 CU7-60D-02-070 ➌ CU7-60D-22-0 72 00 22 40 45 40 5 5 20 25 50 60 0 CU7-72D-02-70 ➌ CU7-72D-22-20 85 00 25 45 55 45 7-/2 5 25 30 60 60 0 CU7-85D-02-380 ➌ CU7-85D-22-420 97 30 30 55 55 55 0 20 30 30 75 75 0 CU7-97D-02-770 ➌ CU7-97D-22-80 Contactors, DC Coil Reversing Three Pole - Series CU7 CU7-85D Reversing (Typical) C7 Contactors NOTE: DC and C coils are not interchangeable. C7-60D 97D contactors have a two winding, 3-lead coil with built-in late break auxiliary contact and coil suppression. Refer to dimensions starting on page 87. Includes: DC operating mechanism Line side coil terminations Mechanical and electrical Interlock ➋ Reversing power wiring Control wiring available; see footnote ➊ Coil Codes ➍➎ DC Coil Code Voltage 2DD 2V 24DD 24V 48DD 48V 0DD 0V 220DD 220V ➊ For -CW Option dd the following to List Price CU7-60D 97D 20 Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ For control wiring, add suffix -CW to catalog number. For example: CU7-60D-22- becomes CU7-60D-22- -CW. ➋ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-02) and are used to electrically interlock the contactors. ➌ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➍ Other voltages available, see page 57. ➎ Coils for CU7-60D 97D reversing contactors include an integrated diode surge suppressor. 39

C7 Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors NEM size labeled contactors The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases, these devices are UL and CS approved for these specialized uses. Where appropriate, contactors also carry approval by specific industry associations such as RI (ir Conditioning and Refrigeration Institute). CNX Special Purpose Contactors CNX Special Purpose Contactors are rated by FL & LR as well as resistive current rated - primarily to meet the demands of the HVC and compressor markets. CNX contactors have all the flexibility of a C7 contactor like easy coil change out, DIN rail mounting and field installable auxiliaries as well as mechanical interlocks not normally associated with true definite purpose contactors. CNX contactors may also be combined with CEP7 or CT7N overload relays to make a special purpose starter. CNX starters are cul rated and labeled as well as RI (ir Conditioning and Refrigeration Institute) approved. CN7 NEM size labeled contactors CN7 contactors are UL Listed in accordance with NEM standards publication ICS-2. CN7 contactors are UL labeled for application under IEC KW, as well as NEM Size, for specified horsepower at various voltages. CN7 contactors have been purposely selected larger to increase the life of the device. Only the devices listed here are available with the NEM size on the UL label. CN7 NEM sized contactors may be combined with all Sprecher + Schuh overload relays to make a NEM sized starter. Hydraulic Elevator Wye-Delta Contactors Most industrial wye-deltas consist of three contactors with interlocks but Hydraulic Elevators are a special application. Hydraulic Elevator wye-deltas consist of a pair of mechanically linked contactors with sufficient auxiliaries for electrical interlocks. The wye-delta is similar to a reversing contactor but the power wiring is different. We offer Hydraulic Elevator contactors with a choice of power wiring inter-connections for ease of installation, or without power wiring inter-connections, allowing the elevator serviceman to make use of the existing power cables. This convenient selection of a complete assembly saves time and effort in the field. 40

Special Use Contactors - C Coil Special Purpose Contactors - Series CNX Non-Reversing, Three Pole Special Purpose Contactors With C Coil (Open type only) ➊ Full Load mps Locked Rotor mps - 3Ø Resistive mps ➌ Maximum Horsepower Ø 3 Ø uxiliary Contacts per Contactor 200V 200V/ 230V 460V 575V 5V 230V 208V 230V 460V 575V NO NC Catalog Number Price 5 9 9 66 25 -/2 3 4 5 0 0 0 CNX-205-65 0 CNX-206-65 30 80 50 20 40 2 5 7-/2 0 20 20 0 CNX-207-235 0 CNX-208-235 0 0 CNX-209-00- 273 40 240 200 60 50 3 5 0 0 25 25 0 CNX-209-0- 292 0 CNX-209-0- 292 0 0 CNX-22-00- 305 50 300 250 200 65 3 7-/2 0 5 30 30 0 CNX-22-0- 325 0 CNX-22-0- 325 0 0 CNX-28-00- 48 90 540 450 360 20 ~ ~ 25 30 60 60 0 CNX-28-0- 500 0 CNX-28-0- 500 CNX-208-20 Special Purpose contactor Description Series CNX Special Purpose Contactors are standard C7 contactors that have been tested, approved and labeled by UL for heating, ventilation and air conditioning (HVC) applications. ➋ C7 Contactors Coil Codes ➋ C Coil Code Voltage Range 50 Hz 60 Hz 24Z 24V 24V 20 0V 20V 208 ~ 208V 220W 200V-220V 208V-240V 240 220V 277V 277 240V 440V 380 380V-400V 480V 480 440V 480V 600 550V 600V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ ll CNX contactors listed here are RI (ir Conditioning and Refrigeration Institute) approved. ➋ Other voltages available, see page 56. ➌ Reference page 77 for Operation Life Data. 4

Special Use Contactors - C Coil NEM Labeled Contactors - Series CN7 C7 Contactors Non-Reversing, Three Pole NEM Labeled Contactors with C Coil ➊ NEM Size Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 5V 230V 200V 230V 460V 575V NO NC Catalog Number 00 /3 -/2 -/2 2 2 0 CN7-2-0-283 0 2 3 3 5 5 0 CN7-6-0-320 Price 2 3 7-/2 7-/2 0 0 0 CN7-37-0-376 2 3 7-/2 0 5 25 25 0 CN7-43-0-670 CN7 NEM labeled contactor (C) 3 7-/2 5 25 30 50 50 0 CN7-85-0-30 pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See page 56 for CN7 coils. Snap-on auxiliary contact blocks available in many configurations. See pages 47-48. vailable as open units or in Type, 3R, 4, 4X and 2 enclosures. Contact your Sprecher + Schuh representative for enclosed pricing. NEM sized starters with C Coils are listed on page C52. CN7 C Coil Codes ➋ CN7-2...85 C Coil Voltage Range Code 50 Hz 60 Hz 24Z 24V 24V 20 0V 20V 208 ~ 208V 220W 200V-220V 208V-240V 240 220V 240V 277 240V 277V 380 380V-400V 440V 480 440V 480V 600 550V 600V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Refer to page 85 for CN7 dimensional information. ➋ Other voltages available, see page 56 for other coil voltage. 42 Discount Schedule B8

Non-Reversing, Three Pole NEM Labeled Contactors with DC Coil ➊ NEM Size Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 5V 230V 200V 230V 460V 575V NO NC Catalog Number 00 /3 -/2 -/2 2 2 0 CN7-2E-0- ➌ 495 0 2 3 3 5 5 0 CN7-6E-0- ➌ 55 2 3 7-/2 7-/2 0 0 0 CN7-37E-0- ➌ 607 2 3 7-/2 0 5 25 25 0 CN7-43E-0- ➌ 879 Price 3 7-/2 5 25 30 50 50 2 CN7-85D-0-64 Special Use Contactors - DC Coil NEM Labeled Contactors - Series CN7 CN7 NEM labeled contactor (24V Electronic DC shown) C7 Contactors pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See page 57 for CN7 DC coils. Snap-on auxiliary contact blocks available in many configurations. See pages 47-48. vailable as open units or in Type, 3R, 4, 4X and 2 enclosures. Contact your Sprecher + Schuh representative for enclosed pricing. NEM sized starters with C Coils are listed on page C52. CN7 Electronic DC Coil Codes ➌➍ CN7-2E...43E DC Coil Code Voltage Range 2E 2V 24E 24V 36E ➎ 36-48V 48E ➎ 48-72V 0E ➎ 0-25V 220E ➎ 220-250V CN7 DC Coil Codes with integrated Diode ➋ CN7-85D DC Coil Code Voltage Range 24DD 24V 0DD 0V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Refer to page 86-87 for CN7 dimensional information. ➋ Other voltages available, see page 57 for other coil voltage. ➌ CN7-2E..43E electronic coils are not interchangeable with non-electronic DC or C coils. ➍ Voltages of 36V DC and greater are supplied with backpack module standard. See page 86. ➎ Not applicable with Electronic Timer accessories (CRZ_7). Discount Schedule B8 43

C7 Contactors Hydraulic Elevator Wye Delta, with C Coils (Two Contactor Type ➊) Maximum Horsepower Three Phase Industrial pplication ➎ UL/CS Elevator Duty ➏ uxiliary Contacts per Contactor Open Type 200V 230V 460V 575V NO ➍ NC ➌ Catalog No. Price 0 5 30 30 0 C7Y2-30-02- -LW 53 0 0 30 30 C7Y2-30-22- -LW 572 5 20 40 40 0 C7Y2-37-02- -LW 66 0 5 30 40 C7Y2-37-22- -LW 655 20 25 50 50 0 C7Y2-43-02- -LW 667 5 5 40 50 C7Y2-43-22- -LW 706 25 30 60 60 0 C7Y2-55-02- -LW 738 TBD TBD TBD TBD C7Y2-55-22- -LW 777 30 40 75 75 0 C7Y2-60-02- -LW 880 5 25 50 60 C7Y2-60-22- -LW 98 40 50 00 00 0 C7Y2-72-02- -LW 996 25 30 60 75 C7Y2-72-22- -LW 035 50 60 25 25 0 C7Y2-85-02- -LW 09 30 40 75 00 C7Y2-85-22- -LW 50 50 60 25 25 0 C7Y2-97-02- -LW 34 TBD TBD TBD TBD C7Y2-97-22- -LW 38 HP Selection Larger sizes available. Contact your Sprecher + Schuh representative. C7-30..37 Reduced Voltage Contactors - C Coil Wye Delta - Series C7Y2 C7Y2-30 Wye-Delta contactor Includes: Line side coil terminations Mechanical and electrical Interlocks ➋ C7Y2-60 97 include a back pan Optional: Power Wiring available but not included (see page 55) ➊➐ Elevator controllers often require additional auxiliary contacts. ➌ C7-30..37 C7-PWD43 C7-43..55 C7-43..55 2M S 2M S C7-PWD43 C7-PWLM37M C7-PWLM55M Coil Codes ➍ C Coil Voltage Range Code 50 Hz 60 Hz 24Z 24V 24V 20 0V 20V 208 ~ 208V 220W 200V-220V 208V - 240V 240 220V 240V 277 240V 277V 380 380V-400V 440V 480 440V 480V 600 550V 600V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code ➊ For -PW Option dd the following to List Price C7Y2-30 37 25 C7Y2-43 55 32 C7Y2-60 97 45 See Coil Codes on this page. C7-60..97 2M C7-PWLM85M C7-60..97 C7-PWD85 ➊ For Contactors with power wiring change catalog number suffix -LW to -PW. For example C7Y2-30-22- -LW becomes C7Y2-30-22- -PW. NOTE: C7Y2-30 55-22- -PW do not include a backpan. ➋ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-02) and are used to electrically interlock the contactors. ➌ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➍ Other voltages available, see page 56. ➎ HP selection based on UL508 for Industrial pplications. ➏ HP selection based on UL/CS Elevator Duty Ratings. ➐ See typical Wye-Delta Wiring Diagram on page C7. S 44

Series CL7 Lighting Contactors Compact contactors for North merican lighting applications Sprecher + Schuh C7 contactors can be used to control a wide variety of lighting loads. These contactors are well suited to handle the high inrush currents typical of this application as well as other non-motor (resistive) loads. Lamps can basically be divided into three categories: Tungsten Filament Lamps - General purpose incandescent - Special purpose incandescent - Infrared - Sodium Iodine Discharge Lamps (with Ballast) - Fluorescent lamps - Mercury vapor - High/low pressure sodium - Quartz - Halogen metal-vapor Mixed Light Lamps In application The tungsten filaments of incandescent lamps have a very low ohmic resistance when cold. s a result, the closing current is very high but also very short. The closing current of discharge lamps (lighting with ballast) is highly inductive (due to series-connected transformers or chokes), and its duration depends on the lamp type. In general, North mericans refer to Lighting Contactor ratings in amperes without distinction between incandescent or ballast type of load. The lighting contactor selection table provided on the following page is for North merican use, so ratings are selected for mixed lamp loads which account for the higher incandescent inrush. Electrically held contactors Electrically held contactors are available for use where the control signal is activated by a timer or other maintained electrical signal. The coil is energized as long as the contactor is closed. This design is well suited for applications where lights are operated frequently or where the control panel is in a remote location. Mechanically held contactors Mechanically held contactors are available for applications where quiet operation or critical lighting is required, i.e., institutions, hospitals and residential/commercial areas. fter the contactor closes, the voltage is disconnected from the operating coil and the contactor is held closed by the mechanical latch. Built-in clearing interlocks allow control from either a momentary or maintained pilot device for the separate pull-in and release functions. C7 Contactors Europeans usually separate the values for incandescent from discharge (ballast) lighting. Both values are provided in the technical section of our general catalog and may be more appropriate for those applying by CE standards. CL7-20 60 are labeled and UL approved for lighting applications 45

Special Use Contactors - C Coil Lighting Contactors Series CL7 & CVL7 C7 Contactors Lighting Contactors with C Coil ➍➎ Continuous Standard Max. C Volts, Type of mpere uxiliary Open Poles to Load Load Rating Contacts Holding Type ➌ for ø 3 for 3ø NO NC Type Catalog Number Price Tungsten or 20 277 480Y/277V Electrical CL7-20-M40-274 Ballast 5 347 600Y/347V 4 0 0 General 30 600 600 Mechanical CVL7-20-M40- -L0 ➊ 532 Tungsten or 30 277 480Y/277V Electrical CL7-30-M40-405 Ballast 25 347 600Y/347V 4 0 0 General 37 600 600 Mechanical CVL7-30-M40- -L0 ➊ 600 Tungsten or 60 277 480Y/277V Electrical CL7-60-M40-687 Ballast 55 347 600Y/247V 4 0 0 General 85 600 600 Mechanical CVL7-60-M40- -L0 ➊ 843 Larger sizes available. Contact your Sprecher + Schuh representative. See catalog page C44 for enclosed lighting contactors. # of Poles Operation of Mechanically Held Contactor with ON-OFF Pushbutton Catalog number CVL7 consists of a CL7 contactor with CV7- mechanical latch. Depressing the ON button energizes the L coil and the contactor closes. The mechanical latch locks the contactor in the closed position. The L coil is then deenergized by the coil, clearing contact UL (Terminals 65-66) to remove voltage. Depressing the OFF button energizes the UL coil, and the mechanical latch releases the contactor. The UL coil is immediately de-energized by the coil clearing contact L (Terminals 3-4) to remove voltage. The contactor is now open. Description The CL7 electrically held contactors and CVL7 mechanical held contactors are cul rated and labeled for tungsten and ballast lighting duty applications at 20, 30, and 60 amperes respectively. C(L)7 Coil Codes ➋ C Coil Code Voltage Range 50 Hz 60 Hz 24Z 24V 24V 20 0V 20V 208 ~ 208V 220W 200V-220V 208V-240V 240 220V 240V 277 240V 277V 380 380V-400V 480V 480 440V 480V 600 550V 600V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ The N.O. auxiliary on the mechanical latch is used by the control circuit and is not available to the customer for other uses. ➋ Other voltages available, see page 56. ➌ Engineering practice permits 2.5 x I e to be applied to a contactor when 3 poles are connected in parallel for single phase discharge lamp (ballast lighting) applications. For example CL7-20-M40- Lighting Contactor plus a C7-P-B23 Paralleling Link can be used on a 50 ballast load. pplying parallel conductors to incandescent lamp loads does NOT result in a greater permissible load. Paralleling Links can be found in the ccessories section. ➍ Lighting contactor applications greater than 4-poles can be achieved. Contact Sprecher + Schuh representative for assistance. ➎ Definite Purpose Contactors can also be used in Lighting Contactor applications. See page 83. 46

ccessories Field Installable C7 Contactors Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block Description NO NC 0 2 Contact rrangement 5 6 52 62 For use with... Standard Contacts Catalog Number Price Bifurcated Contacts Catalog Number ➋ Price C7 all CS7-PV-02 25.70 CS7-PVB-02 38.50 C7 Contactors C7-30...97- -00 C7-PV-02 25.70 C7-PVB-02 38.50 uxiliary Contact Blocks for Top Mounting - 53 6 54 62 C7 all CS7-PV- 25.70 CS7-PVB- 38.50 C7-30...97- -00 C7-PV- 25.70 C7-PVB- 38.50 Top mount auxiliary contact blocks snap-on to the top (front) of any C7 contactor 4-pole auxiliary 2-pole auxiliary contact block (typical) 2 and 4 pole Snap on design - mounts without tools Electronic compatible contacts Mutual positive guidance to the main contactor poles (excluding L types) Several terminal numbering choices even for models wit equal function Late break /early make (L) available Bifurcated Contacts Bifurcated auxiliary contacts provides a higher degree of reliability than the standard cross-stamped auxiliary contacts because it H-bridge divides each movable contact into two sections at the tip of the spanner. Typical application is low-voltage low-current applications (i.e.: PLC). Cross-stamped contacts are good for a minimum of 5m at 7v while bifurcated contacts are good for a minimum of 3m at 5v. 2 0 53 63 54 64 C7-9...23- -0 C7-9...23- -0 C7-PV-S 25.70 C7-PVB-S 38.50 C7 all CS7-PV-20 25.70 CS7-PVB-20 38.50 C7-30...97- -00 C7-PV-20 25.70 C7-PVB-20 38.50 EM LB C7-30...97- -00 C7-PV-L 35 NOT VILBLE ~ 3 2 2 3 3 4 0 0 4 +EM +LB 53 6 7 8 54 62 72 82 53 6 7 83 54 62 72 84 2 3 43 53 22 32 44 54 53 6 73 83 54 62 74 84 53 6 7 8 54 62 72 82 53 63 73 83 54 64 74 84 5 6 7 8 52 62 72 82 53 6 75 87 54 62 76 88 C7-30...97- -00 NOT VILBLE ~ C7-PVB-3 76.0 C7 all CS7-PV-22 50.60 CS7-PVB-22 76.0 C7-30...97- -00 C7-PV-22 50.60 C7-PVB-22 76.0 C7-9...23- -0 C7-9...23- -0 C7-PV-S22 50.60 C7-PVB-S22 76.0 C7 all CS7-PV-3 50.60 CS7-PVB-3 76.0 C7-9...23- -0 C7-9...23- -0 C7-PV-S3 50.60 C7-PVB-S3 76.0 C7 all CS7-PV-3 50.60 CS7-PVB-3 76.0 C7 all CS7-PV-40 50.60 CS7-PVB-40 76.0 C7 all CS7-PV-04 50.60 CS7-PVB-04 76.0 C7 all CS7-PV-L22 70.80 NOT VILBLE ~ ➊ Max. number of auxiliary contacts that may be mounted: C Coil and Electronic DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, 2-N.O. contacts on the side, 4-N.C. front or side: 6 total. True DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, or max. 2-N.O. contacts on side, 4-N.C. front or side: 4 total. ➋ Detailed ratings can be found on page 75. 47

ccessories Field Installable C7 Contactors C7 Contactors Side Mount uxiliary Contact Blocks ( & 2 Pole) ➊ Contact Block Description NO NC -pole (typical) uxiliary Contact Blocks for Side Mounting - ➊ and 2-pole Two way numbering for right or left mounting on the contactor Snap-on design - mounts without tools Electronic compatible contacts down to 24V, 20m Late break / early make (L) available Mutual positive guidance to the main contactor poles (excluding L-types) Contact rrangement For use with... Catalog Number ➌ Price 0 C7 all C7-P-0 6.00 0 C7 all ➋ C7-P-0 6.00 0 2 C7 all C7-P-02 25.70 C7 all ➋ C7-P- 25.70 2 0 C7 all ➋ C7-P-20 25.70 2-pole (typical) EM LB C7 all C7-P-L 35.00 ➊ Max. number of auxiliary contacts that may be mounted: C Coil contactors - max. 4 N.O. contacts on the front of the contactor, 2-N.O. contacts on the side, 4-N.C. front or side: 6 total. DC Coil contactors - max. 4 N.O. contacts on the front of the contactor, or max. 2-N.O. contacts on side, 4-N.C. front or side: (4) total. ➋ Left mounting only is recommended when using with C7-9 C7-23 contactors. These contactors have built-in auxiliaries, which will result in duplicate terminal markings if mounted on the right. ➌ Detailed ratings can be found on page 75. 48

Control Modules ➊ Module Description Pneumatic Timing Module The contacts in the Pneumatic Timing Element switch after the delay time. The contacts on the main contactor continue to operate without delay. Continuous adjustment range ccessories Field Installable C7 Contactors For use with... Connection Diagrams Function Catalog Number Price C7 all C7 all ON-Delay 0.3 30s.8 80s OFF-Delay 0.3 30s.8 80s CZE7-30 CZE7-80 CZ7-30 CZ7-80 54 54 C7 Contactors 0 240V 50/60Hz 0 250V DC Electronic Timing Module ➋ ON-Delay The contactor is energized at the end of the delay time. C7 all 0. 3s 30s 0 80s 24 48V DC CRZE7-3-0/240 CRZE7-30-0/240 CRZE7-80-0/240 92.30 0. 3s 30s 0 80s CRZE7-3-24/48VDC CRZE7-30-24/48VDC CRZE7-80-24/48VDC 00 Electronic Timing Module ➋ OFF-Delay fter interruption of the control signal, the contactor is de-energized at the end of the delay time. C7 all C7-9 C7-37 0 240V 50/60Hz 0.3 3s 30s 0 80s 24V C 50/60Hz 0.3 3s 30s 0 80s CRZ7-3-0/240 CRZ7-30-0/240 CRZ7-80-0/240 00 CRZ7-3-24VC CRZ7-30-24VC CRZ7-80-24VC 00 Electronic Timing Module ➋ Wye-Delta Transition Timer Contactor K3 (Y) is de-energized and contactor K2 (D) is energized after the end of the set transition time. Switching delay at 50ms. C7 all K (H) K2 (D) K3 (Y) 0 240V 50/60Hz 30s CRZY7-30-0/240 00 Continuous adjustment range High repeat accuracy K K3 K2 CM7 CM7-02 Mechanical/Electrical Interlocks Common to all C7 contactors; interlocks different contactor sizes Mechanical and electrical interlocking possible in one module by means of integrated auxiliary contacts Dovetail (C7-S9) connector included (9mm) C7 all ➊ 2 22 2 22 Mechanical Without auxiliaries Mechanical/ Electrical Two NC aux contacts CM7 3.90 CM7-02 38.40 ➊ Not for use with C7-40 or C7-90 (4-pole) contactors. ➋ Not available for use on C7-9E 55E coil voltage 48V 220V. 49

ccessories Field Installable C7 Contactors C7 Contactors Control Modules (continued) Module Description Mechanical Latch Following contactor latching, the contactor coil is immediately de-energized by the NC auxiliary contact (65-66). Electrical or manual release NO + NC auxiliary switch Suitable for all C7 contactors For use with ll C7 ➏ Connection Diagrams Catalog Number Price CV7-- Replace with coil code below (See pplication Note below) 89.70 CV7 Mechanical Latch Coil Codes ➊➋➍➎ Coil Code pplication Range Latch & Contactor Coil Rating 50 Hz 60 Hz VDC 24Z 24 VC 24 VC 2 VDC 24V 50/60 Hz 48Z 48 VC 48 VC 24 VDC 48V 50/60 Hz 0 00 VC 0 VC 48 or 60VDC 0V50/0V60 20 0 VC 20 VC ~ 0V50/20V60 220W ~ 208 240 VC ~ 208 240V60 230Z 230 VC 230 VC 0 VDC 230V 50/60 Hz 240Z 240 VC 240 VC 25 VDC 240V 50/60 Hz 277 240 VC 277 VC ~ 240V50/277V60 380 380 400 VC 440 VC ~ 380 400V50/440V60 400Z 400 VC 400 VC 220 VDC 400V 50/60 Hz 45 400 45 VC ~ ~ 400 45 V50 Hz 480 440 VC 480 VC ~ 440V50/480V60 600 ➌ 550 VC 600 VC ~ 550V50/600V60 PPLICTION NOTE: The CV7 Mechanical Latch for C7 may be used for both C and DC applications; however when using DC control circuit the user must apply the following rules for coil selection of the contactor and latch combination: When DC control circuits are required use C7-9 55 contactors with C coil and latch with C coil. From column VDC in the table on the left, identify the required application DC control voltage and then select its specific Coil Code. Enter this Coil Code to complete the catalog numbers for both the contactor and latch (i.e.: 25V DC control circuit should use a 240Z coil code in both the C7-9 55 and CV7). This works because both coils are only momentary energized and coil clearing contacts breaks the circuit after closing or opening. The above statement does NOT apply to applications C7-60D 97D two-winding DC coil contactors. When DC control circuits are required use C7-60D 97D contactors with standard two winding DC coil and the CV7 latch with C coil selected from the table, top left. (i.e.: 25V DC control circuit should use 25DD coil code in the contactor and 240Z C coil code in the CV7 latch). The C7-9E 55E contactor uses an electronic DC coil and the CV7 latch coil code should be chosen from the table on the left. (i.e.: 24V DC control circuit select C7-9E 55E with code 24E and CV7 latch uses a 48Z C coil code). ➊ Other voltages available. Contact your Sprecher + Schuh representative. ➋ CV7 must be wired for momentary operation only. ➌ Use 600V C when 575 V is required. ➍ Command duration 0.03 0 seconds. ➎ Coil operating limits on CV7- match those of the contactor it is being used with. ➏ Not for use with C7-90 (4-pole) contactors. 50

ccessories Field Installable C7 Contactors Control Modules (continued) Module Description Electronic Interface Interface between the DC control signal from a PLC and the C operating mechanism of the contactor. Requires no additional surge suppression for the coils Suitable for all C7 contactors ➋ For use with C7 all (with C control) Connection Diagrams Function Catalog Number Price Input Output 24V DC ➊ 0 CRI7E-24 2V DC 240V C CRI7E-2 48V DC CRI7E-48 Gray is special order 62.20 C7 Contactors C7 all (with C control) RC Module - C Control (50/60Hz) 24 48V 0 280V CRC7-48 CRC7-280 33.70 380 480V CRC7-480 Surge Suppressors - Limits coil switching transients. Plug-in, coil mounted Suitable for all C7 contactors C7-9C 43C (with conventional DC control) C7 all (with C control) C7-9C 43C (with conventional DC control) Diode Module - DC Control 2-250VDC CRD7-250 ➌ Varistor Module - C/DC Control 2 55VC/ 2 77VDC 56 36VC/ 78 80VDC 37 277VC/ 8 350VDC 33.70 CRV7-55 ➌ 7.20 CRV7-36 ➌ 8.80 CRV7-277 ➌ 8.80 278 575VC CRV7-575 ➌ 8.80 ➊ Control voltage 8 30V DC (0 5m) ➋ Minimum actuation current is 5 volts, 2ma. The leakage current is <M for the following: CRI7E-2 @ 2.5 VDC input CRI7E-24 @5 VDC input CRI7E-48 @ 0 VDC input. ➌ Electronic DC Contactors (C7-9E 55E) include internal surge protection and do not require additional external surge protection. 5

C7 Contactors C Voltage Sag Immunity Modules Module Description Module Input Control circuit voltage range Full-Wave Bridge Rectifier Module Output For use with C7-60 97 contactors with DC coil Semi-F47 Modules For C7 Contactors Catalog Number SEMI-F47-Module 24-250 VC 24-250 VDC ➊ C7-SF47 03 Price Semi-F47-Module with...30s on-delay timer 0-250 VC 0-250 VDC ➊ C7-SF4730 66 Sprecher + Schuh s C7-SF47 module meets the Semi-F47 C voltage sag immunity requirements to 50% voltage sag for 200 ms. Voltage sags can affect the readiness and operation of contactors and starters, resulting in shut downs, lost production, and diminished revenue. It is essential for process equipment to be compatible with its electrical environment. The C7-SF47 voltage sag immunity module is an essential component to achieve equipment reliability during voltage sag events. Product Features Meets Semi-F47 standard requirements For use with C7-60 97 contactors with DC coils. full-wave bridge rectifier internal to the C7-SF47 module provides C to DC coil voltage rectification. Suitable for contactor range (with screw terminals) - C7-60...97, 3-Pole contactors - C7-90, 4-Pole contactor Optional to 30 seconds On-Delay timer function. Benefits Direct mounting to the coil terminals of the C7 contactors. Only 24 mm is added to the component height. Direct electrical connection to the contactor. Customer coil power connections are made at the terminals of the C7-SF47 module The C7-SF4730 module includes a to 30 seconds adjustable On-Delay timer in addition to the voltage sag immunity functionality. Two independent functions in a single module. Percentage of Equipment Nominal Voltage Duration of Voltage Sag in Seconds 0.05 0. 0.2 0.5.0 00 90 80 70 60 50 40 30 20 0 0 VOLTGE SG DURTION VOLTGE SG Seconds Milliseconds Cycles at 60 hz Cycles at 50 hz Percent (%) of Equipment Nominal Voltage < 0.05 s < 50 ms < 3 cycles < 2.5 cycles Not specified 0.05 to 0.2 s 50 to 200 ms 3 to 2 cycles 2.5 to 0 cycles 50% 0.2 to 0.5 s 200 to 500 ms 2 to 30 cycles 0 to 25 cycles 70% 0.5 to.0 s 500 to 000 ms 30 to 60 cycles 25 to 50 cycles 80% >.0 s > 000 ms > 60 cycles > 50 cycles Not specified ➊ Input C control circuit voltage must be matched when selecting the contactor/relay DC coil voltage. 52

Terminal Lug Kits ➊ Component Description 3 Pole Lug Kit llows larger wires to be used with the contactor. Ideal for wye-delta, reversing and multispeed contactors and starters. Can increase IEC C- current rating, as well as the UL/CS continuous current (resistive) rating of the contactor. Three pole kit used for smaller contactors. For use with... C7-9...23 -line side -load side IEC (40 C) Maximum Resistive Current Ratings () ➋ IEC (60 C) UL/CS (40 C) Pkg. Qty. 45 45 40 ccessories Field Installable C7 Contactor Terminal Lug Kits Catalog Number ➊ C7-P-KN23 C7-P-KL23 Price Each 39.20 C7-30...37 60 55 55 C7-P-K37 53.60 C7 Contactors Pole Lug Kit llows larger wires to be used with the contactor. Ideal for wye-delta, reversing and multispeed contactors and starters. Can increase C- current rating of the contactor. One pole kit used for larger contactors. C7-43 55 90 75 75 3 ➌ C7-P-K43 25.80 C7-60...97 30 30 30 3 ➌ C7-P-K85 3.60 Paralleling Links ➊➋ Component Description For use with... IEC (40 C) Maximum Resistive Current Ratings () ➋ IEC (60 C) UL/CS (40 C) Pkg. Qty. Catalog Number ➊ Price Each 3 Pole Paralleling Link llows smaller C7 contactors to be used on single-phase resistive applications. By paralleling the three power poles, the contacts see only a portion of the actual load. ➍ C7-9...23 00 00 00 2 ➌ C7-P-B23 3.50 C7-30...37 50 35 50 2 ➌ C7-P-B37 20.0 Quick Connectors Component Description For use with... Pkg. Qty. Catalog Number Price Each Stab Connectors - Dual stab (0.250 inch) C7-9 97 coil term. C7-9 23 power term. C7 accessories 20 00 00 C7-SC2 C7-SC0 C4-SC.92.84.92 ➊ culus pproved (File E3396). ➋ Lighting applications are not considered purely resistive loads. Therefore, the IEC and UL/CS resistive ratings listed here do not apply to lighting loads. Lighting contactor ratings are provided in the Technical Information section. ➌ Must be ordered in multiples of package quantity. For example on C7-P-K43, order minimum quantity of 3 for one package of 3 pieces. Price is per piece. ➍ Engineering practice permits 2.5 x I e to be applied to a contactor when 3 poles are connected in parallel for single phase discharge lamp (ballast lighting) applications. 53

ccessories Field Installable C7 Contactors C7 Contactors Reversing Components Component Description For Use With Dovetail Connectors Connects multiple contactor and starter assemblies together. Pkg. Qty. Catalog Number Price Each C7 all 0 C7-S9.33 Reversing Power Wiring Kit - ➊ Provides a solid wireless connection for reversing applications. May be used with both solid state and thermal O/L relays. C7-9 2 C7-6 23 C7-30 37 C7-43 55 C7-60 97 CUT7-PW23 6.00 CUT7-PW37 CUT7-PW55 CUT7-PW85 8.90 35.00 89.70 Reversing Power Wiring Kits Only the kits are catalog items. Single components are available by special order in bulk packages of 20 pieces. Kit = CUT7-PW23 C7-PWNM23M Kit = CUT7-PW37 C7-PWNM37M Kit = CUT7-PW55 C7-PWN55 C7-43..55 C7-43..55 Kit = CUT7-PW85 C7-PWNM85M C7-60..97 C7-60..97 C7-PWLM23M C7-PWLM37M C7-PWLM55M ssembly Components Component Description For Use With Pkg. Qty. Catalog Number Price Each Protective Covers - Protects against unintended manual operation. C7 all C7-SCC 3.27 C7-PWLM85M Protective Covers - For front mounted auxiliary contacts, pneumatic timers and latches. CS7-PV, C7-PV, CZE7, CZ7, CV7 C7-SCF.39 DIN-rail - 2 meter lengths ( 6' 6"); price per rail Top Hat, low profile Top Hat, high profile C7 all 20 0 3F 3F See page N30 Marking Systems Component Description Pkg. Qty. Catalog Number Price Each Label Sheet sheet with 05 self-adhesive paper labels, each 6 x 7mm Marking Tag Sheet - sheet with 60 perforated paper labels each, 6 x 7mm. To be used with transparent cover. Transparent Cover - To be used with Marking Tag Sheets. C7-FMS.77 C7-FMP.39 00 ➋ C7-FMC.4 Tag Carrier - For marking with marker cards and tags. See page N35 for complete listing of available cards and tabs. 00 ➋ C7-FM2.4 ➊ culus pproved (File E3396). ➋ Minimum quantity is one package of 00. Price is each x 00 = package price. 54

Wye-Delta Starter Kits ➊ Wye-Delta power wiring kits were designed to aid in the field assembly of open-transition wyedelta starters that use C7 contactors. These kits include line, load and start-point (shorting) connections. ssembling a wye-delta starter requires the use of the following components: Contactors and overload relay Mechanical / Electrical Interlock (Cat.No: CM7-02) Electronic Wye-delta Timer (Cat. No: CRZY7-30-0/240) Dovetail Connector to couple M and 2M contactor (Cat. No: C7-S9); optional Three Contactor ssembly Components Kit = CYT7-PW23 C7-PWNM23M Kit = CYT7-PW37 C7-PWNM37M 3-Phase Rating kw (50Hz) HP (60Hz) Use with catalog number... 380V Delta Wye 230V 45V 500V 690V 200V 230V 460V 575V M 2M S 5.5 8 8 8 5 5 0 0 C7-9 C7-9 C7-9 7.5 5 7.5 5 5 C7-2 C7-2 C7-9 0 4 5 4 7.5 0 20 20 C7-6 C7-6 C7-2 4 2 2 9 7.5 0 25 25 C7-23 C7-23 C7-2 8 28 28 28 0 5 30 30 C7-30 C7-30 C7-6 9 35 35 32 5 20 40 40 C7-37 C7-37 C7-23 23 40 40 4 20 25 50 50 C7-43 C7-43 C7-37 30 45 45 45 25 30 60 60 C7-55 C7-55 C7-30 33 58 60 56 30 40 75 75 C7-60 C7-60 C7-37 39 69 67 70 40 50 00 00 C7-72 C7-72 C7-43 47 82 82 8 50 60 25 25 C7-85 C7-85 C7-60 50 90 90 90 50 60 25 25 C7-97 C7-97 C7-60 Kit = CYT7-PW55 C7-PWNM55M C7-PWD43 For 3 contactor assembly ➋ Catalog Number ccessories Field Installable Power Jumper Connection Reversing Power Connection Price CYT7-PW23 20.60 CYT7-PW37 25.50 CYT7-PW55 38.90 CYT7-PW72 75.00 CYT7-PW85 00. C7 Contactors Shorting Bar C7 Contactors C7-55 C7-55 C7-PWLM23M C7-PWY55 Kit = CYT7-PW72 C7-PWNM85M Kit = CYT7-PW72 C7-PWNM85M Kit = CYT7-PW85 C7-PWNM85M C7-PWD85 C7-PWD43 C7-PWD43 C7-60..97 C7-60..97 C7-60..97 C7-60..97 C7-60..97 C7-60..97 C7-60..97 C7-PWLM85M Two Contactor ssembly Components When Connecting... Delta Wye 2M S C7-30 C7-30 C7-37 C7-37 C7-43 C7-43 C7-55 C7-55 C7-60 C7-60 C7-72 C7-72 C7-85 C7-85 C7-97 C7-97 Load Side Power Connection Catalog Number Price C7-PWLM37M 7.00 C7-PWLM55M 7.00 Shorting Bar Catalog Number Price C7-PWD43 3.00 C7-PWLM85M 43.00 C7-PWD85 22.00 C7-30..37 C7-PWLM37M C7-30..37 C7-PWLM85M C7-PWD43 2M S 2M S C7-60..97 2M C7-43..55 C7-PWLM55M C7-60..97 S C7-43..55 C7-PWD85 C7-PWD43 Two Contactor Wiring Connections are for Hydraulic Elevator Wye-Delta Contactors C7Y2 ➊ culus pproved (File E3396). ➋ Individual parts of kits are available for unique applications by special order. Contact your Sprecher + Schuh Representative. 55

C7 Contactors Renewal Coils -.C. ➊➋➌ C Control Voltages C Coil Codes ➋ For use with contactor... C7-9...6 C7-23...37 C7-43 55 C7-60...85 C7-97 C7-9-M...6-M... C7-23-M...37-M... ~ ~ C7-90-M... CQ7-6 CQ7-37 ~ ~ ~ CNX-205...206 CNX-207...209 CNX-22 CNX-28 ~ CN7-2 6 CN7-37 C7-40-M, CN7-43 CN7-85 ~ ~ CL(V)7-20-M40 CL(V)7-30-M40 ~ CL(V)7-60-M40 50 Hz 60 Hz 50/60 Hz Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. ~ 2V ~ 2B T006 TC006 TD006 TE006 TF006 2V ~ ~ 2 T404 TC404 TD404 TE404 TF404 ~ 24V ~ 24B T03 TC03 TD03 TE03 TF03 24V ~ ~ 24 T407 TC407 TD407 TE407 TF407 ~ ~ 24V 24Z T855 TC855 TD855 TE855 TF855 32V 36V ~ 36 T48 TC48 TD48 TE48 TF48 36V ~ ~ 36 T40 TC40 TD40 TE40 TF40 42V 48V ~ 48 T482 TC482 TD482 TE482 TF482 48V ~ 48 T44 TC44 TD44 TE44 TF44 ~ ~ 48V 48Z T860 TC860 TD860 TE860 TF860 00V 00...0V 00 0 T86 TC86 TD86 TE86 TF86 0V 20V ~ 20 T473 TC473 TD473 TE473 TF473 ~ ~ 0V 0Z T856 TC856 TD856 TE856 TF856 20V ~ ~ 20 T425 TC425 TD425 TE425 TF425 5V 27V ~ 27 T424 TC424 TD424 TE424 TF424 27V ~ ~ 27 T428 TC428 TD428 TE428 TF428 200V 200.. 220V 200V 220 T862 TC862 TD862 TE862 TF862 ~ 208V ~ 208 T049 TC049 TD049 TE049 TF049 200...220V 208.. 240V ~ 220W T296 TC296 TD296 TE296 TF296 220V 240V ~ 240 T474 TC474 TD474 TE474 TF474 220...230V 260V ~ 230 T44 TC44 TD44 TE44 TF44 ~ ~ 200...230V 230W T864 TC864 TD864 TE864 ~ ~ ~ 230V 230Z T85 TC85 TD85 TE85 TF85 230...240V ~ ~ 240 T440 TC440 TD440 TE440 TF440 240V 277V ~ 277 T480 TC480 TD480 TE480 TF480 ~ ~ 240V 240Z T858 TC858 TD858 TE858 TF858 ~ 347V ~ 347 T065 TC065 TD065 TE065 TF065 ~ 380V ~ 380B T067 TC067 TD067 TE067 TF067 380V...400V 440V ~ 380 T07 TC07 TD07 TE07 TF07 ~ ~ 400V 400Z T863 TC863 TD863 TE863 TF863 400V...45V ~ ~ 45 T457 TC457 TD457 TE457 TF457 440V 480V ~ 480 T475 TC475 TD475 TE475 TF475 ~ ~ 440V 440Z T859 TC859 TD859 TE859 TF859 500V ~ ~ 500 T479 TC479 TD479 TE479 TF479 550V 600V ~ 600 T476 TC476 TD476 TE476 TF476 Price 65.70 95.50 3.00 33.00 33.00 Renewal Coils C7 Contactors.C. Control C7 C Coil (typical) ➊ Other coil voltages available. Contact your Sprecher + Schuh representative for information. ➋ C Codes in bold letters and shaded indicate coils that are standard stocked items. ➌ C and DC coils on CNX-xxx contactors are not interchangeable. 56 Discount Schedule B6

Renewal Coils - D.C. ➊➋ DC Control Voltages DC Coil Codes ➋ Electronic DC Replacement Coils ➏ C7-9E...6E C7-9E-M... 6E-M... CN7-2E 6E For use with contactor... C7-23E...37E C7-23E-M... CN7-37E C7-43E 55E C7-40E-M... CN7-43E Two Winding DC Replacement Coils For use with contactor... C7-60D...85D ➎ CNX7-28 CN7-85D C7-97D ➎ C7-90D-M... Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. 9V Diode ➌ 9DD ~ ~ ~ TE766M TF766M 2V Electronic 2E TC708E TC708E TD708E ~ ~ 2V Diode 2DD ~ ~ ~ TE708M TF708M 24V Electronic 24E TC74E TC74E TD74E ~ ~ 24V Diode ➍ 24DD ~ ~ ~ TE74M TF74M 36-48V Elec 36E TC79E TC79E TD79E ~ ~ 36V Diode 36DD ~ ~ ~ TE79M TF79M 48-72V Elec 48E TC724E TC724E TD724E ~ ~ 48V Diode 48DD ~ ~ ~ TE724M TF724M 60V Diode 60DD ~ ~ ~ TE774M TF774M 64V Diode 64DD ~ ~ ~ TE727M TF727M 72V Diode 72DD ~ ~ ~ TE728M TF728M 80V Diode 80DD ~ ~ ~ TE729M TF729M 0-25V Elec 0E TC733E TC733E TD733E ~ ~ 0V Diode 0DD ~ ~ ~ TE733M TF733M 5V Diode 5DD ~ ~ ~ TE734M TF734M 25V Diode 25DD ~ ~ ~ TE737M TF737M 220-250V Elec 220E TC747E TC747E TD747E ~ ~ 220V Diode 220DD ~ ~ ~ TE747M TF747M 230V Suppres. 230DS ~ ~ ~ TE749F TF749F 250V Suppres. 250DS ~ ~ ~ TE75F TF75F Price (coil with diode) 43 43 60 76 76 Note: The DD coils listed above include an integrated bidirectional diode. Drop out time of this design is significantly improved when compared to an external diode. See ratings on page 69. Renewal Coils C7 Contactors D.C. Control 2V & 24V Electronic DC coil 36V 220V Electronic DC coil with Back Pack Two Winding DC coil (typical) ➎ C7 Contactors ➊ Other coil voltages and coils for obsolete products may be available. Contact your Sprecher + Schuh representative for information. ➋ DC Codes in bold letters and shaded indicate coils that are standard stocked items. ➌ Voltage operating range: 0.65.3 x U s. ➍ Voltage operating range: 0.7.25 x U s. ➎ C7-60D 97D contactors have a two winding coil with built-in late break auxiliary contact and coil suppression. ➏ C7-9E...55E electronic coils are not interchangeable with non-electronic DC or C coils Discount Schedule B6 57

C7 Contactors Replacement Contactors Cross Reference, Series C to Series C7 (Open Type Only) ➊ Ratings for Switching C Motors (C2 / C3 / C4) Series CU I e [] kw (50 Hz) UL/CS HP (60 Hz) Obsolete 400V / Ø 3 Ø Catalog C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V Number 3 5 5 0 0 CU-0 Obsolete Contactor Cross Reference Series C7 Equivalent Catalog Number 6 32 5.5 7.5 7.5 7.5 3 5 5 0 5 C7-6-0 2 3 7-/2 7-/2 5 20 CU-4 23 32 7.5 3 0 2 3 5 7-/2 5 5 C7-23-0 2 5 7-/2 0 20 25 CU-6 30 65 0 5 5 5 2 5 7-/2 0 20 25 C7-30-0 3 7-/2 0 5 30 40 CU-25 43 85 3 22 25 22 3 7-/2 0 5 30 30 C7-43-0 72 00 22 40 45 40 5 5 20 25 50 60 C7-72-0 5 5 25 25 50 60 CU-40 85 00 25 45 55 45 7-/2 5 25 30 60 60 C7-85-0 7-/2 20 30 30 60 75 CU-55 97 30 30 55 55 55 0 5 30 30 75 75 C7-97-0 C or C3 to C7 Contactors CU-0 Contactor Replacement Contactors Cross Reference, Series C3 to Series C7 (Open Type Only) ➊ Ratings for Switching C Motors (C2 / C3 / C4) Series C3 I e [] kw (50 Hz) UL/CS HP (60 Hz) Obsolete 400V / Ø 3 Ø Catalog C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V Number 2 2 5 7-/2 C3-9-0 Series C7 Equivalent Catalog Number 9 32 3 4 4 4 /2 /2 2 2 5 7-/2 C7-9-0 3 3 7-/2 0 C3-2-0 2 32 4 5.5 5.5 5.5 /2 2 3 3 7-/2 0 C7-2-0 5 5 0 5 C3-6-0 6 32 5.5 7.5 7.5 7.5 3 5 5 0 5 C7-6-0 5 5 0 5 C3-23-0 23 32 7.5 3 0 2 3 5 7-/2 5 5 C7-23-0 7-/2 7-/2 5 20 C3-23-0 30 65 0 5 5 5 2 5 7-/2 0 20 25 C7-30-0 0 0 20 25 C3-30-0 0 0 25 30 C7-37-0 37 65 8.5/20 20 8.5 3 5 0 0 25 30 C3-37 43 85 3 22 25 22 3 7-/2 0 5 30 30 C7-43-0 0 5 30 40 C3-43 5 20 40 50 C3-60 55 85 5 30 30 22 5 0 5 20 40 40 C7-55-0 60 00 8.5 32 37 32 5 0 5 20 40 50 C7-60-0 20 20 50 60 C3-72 72 00 22 40 45 40 5 5 20 25 50 60 C7-72-0 85 00 25 45 55 45 7-/2 5 25 30 60 60 C7-85-0 97 30 30 55 55 55 0 5 30 30 75 75 C7-97-0 C3-72 Contactor ➊ vailable auxiliary contacts may vary. See selection pages for more information. 58

Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts Technical Information C7 3-Pole Contactors C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 C 50/60Hz [V] 5, 200, 208, 230, 240, 380, 400, 45, 460, 500, 575, 690V DC [V] 24, 48, 0, 5, 220, 230, 300, 440V Operating Frequency for C Loads [Hz] 50...60Hz C7 Contactors Switching Motor Loads Standard IEC Ratings C-2, C-3, C-4 230V [] 2 5 20 26.5 35 38 44 56 62 72 85 96 DOL Reversing 240V [] 2 5 20 26.5 35 38 44 56 62 72 85 95 50Hz/60 C 400V [] 9 2 6 23 30 37 43 55 60 72 85 97 45V [] 9 2 6 23 30 37 43 55 60 72 85 97 500V [] 7 0 4 20 25 30 38 44 55 67 80 78 690V [] 5 7 9 2 8 2 25 25 34 42 49 57 230V [kw] 3 4 5.5 7.5 0 3 5 8.5 22 25 30 240V [kw] 3 4 5.5 7.5 0 3 5 8.5 22 25 30 400V [kw] 4 5.5 7.5 5 8.5 22 30 32 40 45 55 45V [kw] 4 5.5 7.5 5 20 22 30 32 40 45 55 500V [kw] 4 5.5 7.5 3 5 20 25 30 37 45 55 55 690V [kw] 4 5.5 7.5 0 5 8.5 22 22 32 40 45 55 UL/CS DOL Reversing 5V [] 9.8 9.8 6 24 24 34 34 56 56 56 80 00 60Hz Ø 230V [] 0 2 7 7 28 28 40 50 50 68 68 88 5V [HP] /2 /2 2 2 3 3 5 5 5 7-/2 0 230V [HP] /2 2 3 3 5 5 7-/2 0 0 5 5 20 200V [] 7.8 7.5 7.5 25.3 32.2 32.2 48.3 48.3 62. 78.2 92 3Ø 230V [] 6.8 9.6 5.2 22 28 28 42 54 54 68 80 80 460V [] 7.6 4 2 27 34 40 52 52 65 77 96 575V [] 9 7 7 27 32 32 4 52 62 62 77 200V [HP] 2 3 5 5 7-/2 0 0 5 5 20 25 30 230V [HP] 2 3 5 7-/2 0 0 5 20 20 25 30 30 460V [HP] 5 7-/2 0 5 20 25 30 40 40 50 60 75 575V [HP] 7-/2 0 5 5 25 30 30 40 50 60 60 75 C2 [ops/hr] 450 450 450 400 400 400 400 400 300 300 200 200 Maximum Operating Rate C3 [ops/hr] 700 700 700 600 600 600 600 600 500 500 500 500 (at max. amps) ➊ C4 [ops/hr] 200 50 20 80 80 70 70 70 70 60 50 50 ➊ See page 82 for additional detail. 59

C7 Contactors Technical Information C7 3-Pole Contactors Electrical Data C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 Switching Motor Loads (continued) C-4 230V [] 4.3 6.6 9 9 2 4 6.5 22 25.5 3 38 44 200,000 Op. Cycles 240V [] 4.3 6.6 9 9 2 4 6.5 22 25.5 3 38 44 50Hz 400V [] 4.3 6.6 9 9 2 4 6.5 22 25.5 3 38 44 45V [] 4.3 6.6 9 9 2 4 6.5 22 25.5 3 38 44 500V [] 4.3 6.6 9 9 2 4 6.5 22 25.5 3 38 44 690V [] 4.3 6.6 9 9 2 4 6.5 22 25.5 3 38 44 230V [kw] 0.75.5 2.2 2.2 3 3.7 4 5.5 6.3 7.5 240V [kw] 0.75.5 2.2 2.2 3 4 4 5.5 7.5 7.5 400V [kw].8 3 4 4 5.5 6.3 7.5 3 5 20 22 45V [kw].8 3 4 4 5.5 6.3 7.5 3 7 20 22 500V [kw] 2.2 3.7 5.5 5.5 7.5 7.5 0 5 20 25 30 690V [kw] 3 5.5 7.5 7.5 0 5 8.5 22 25 32 37 60Hz Ø 5V [] 4.3 6.6 9 0 2 4 6.5 22 25.5 3 38 44 230V [] 4.3 6.6 9 0 2 4 6.5 22 25.5 3 38 44 5V [HP] /8 /4 /3 /2 /2 3/4.5 2 2 3 3 230V [HP] /3 /2 -/2 2 2 2 3 3 5 5 7-/2 200V [] 4.3 6.6 9 0 2 4 6.5 22 25.5 3 38 44 3Ø 230V [] 4.3 6.6 9 0 2 4 6.5 22 25.5 3 38 44 460V [] 4.3 6.6 9 0 2 4 6.5 22 25.5 3 38 44 575V [] 4.3 6.6 9 0 2 4 6.5 22 25.5 3 38 44 200V [HP] 3/4 2 2 3 3 3 5 7-/2 7-/2 0 0 230V [HP] -/2 2 3 3 3 5 7-/2 7-/2 0 0 5 460V [HP] 2 3 5 5 7-/2 0 0 5 5 20 25 30 575V [HP] 3 5 7-/2 7-/2 0 0 0 20 20 25 30 40 Maximum Operating Rate [ops/ hour] 250 250 220 200 200 200 200 200 20 20 20 20 Wye-Delta (Star Delta) 230V [kw] 5.5 7.5 0 3 7 20 22 30 32 37 45 50 50 Hz 240V [kw] 5.5 7.5 0 3 8.5 20 22 30 32 40 50 50 400V [kw] 7.5 0 3 20 25 32 40 45 55 63 80 90 45V [kw] 7.5 5 22 25 37 40 45 55 63 80 90 500V [kw] 7.5 5 22 25 32 45 45 63 80 90 90 690V [kw] 7.5 0 3 8.5 25 32 40 45 55 63 80 90 200V [HP] 5 5 7-/2 7-/2 0 5 20 25 30 40 50 50 60 Hz 230V [HP] 5 7-/2 0 0 5 20 25 30 40 50 60 60 460V [HP] 0 5 20 25 30 40 50 60 75 00 25 25 575V [HP] 0 5 20 25 30 40 50 60 75 00 25 25 UL/CS Elevator Duty 200V [] 7.8.0.0 7.5 25.3 25.3 32.2 ➊ 32.2 48.3 62. ➊ 230V [] 6.8 9.6 5.2 5.2 22.0 28.0 28.0 42.0 54.0 68.0 460V [] 7.6.0 4.0 2.0 27.0 27.0 34.0 40.0 52.0 65.0 575V [] 6. 9.0.0 7.0 22.0 27.0 32.0 4.0 52.0 62.0 200V [HP] 2 3 3 5 7-/2 7-/2 0 0 5 20 230V [HP] 2 3 5 5 7-/2 0 0 5 20 25 460V [HP] 5 7-/2 0 5 20 20 25 30 40 50 575V [HP] 5 7-/2 0 5 20 25 30 40 50 60 ➊ Testing incomplete at the time of this printing. 60

Electrical Data Technical Information C7 3-Pole Contactors C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 C- Load, 3Ø Switching I th [] 32 32 32 32 65 65 85 85 00 00 00 30 mbient Temperature 40º C 230V [kw] 3 3 3 3 26 26 34 34 40 40 40 52 240V [kw] 3 3 3 3 27 27 35 35 42 42 42 54 400V [kw] 22 22 22 22 45 45 59 59 69 69 69 90 45V [kw] 23 23 23 23 47 47 6 6 72 72 72 93 500V [kw] 28 28 28 28 56 56 74 74 87 87 87 3 690V [kw] 38 38 38 38 78 78 02 02 20 20 20 55 mbient Temperature 60º C I th [] 32 32 32 32 65 65 75 75 00 00 00 0 230V [kw] 3 3 3 3 26 26 25 25 40 40 40 44 240V [kw] 3 3 3 3 27 27 26 26 42 42 42 46 400V [kw] 22 22 22 22 45 45 44 44 69 69 69 76 45V [kw] 23 23 23 23 47 47 45 45 72 72 72 76 500V [kw] 28 28 28 28 56 56 55 55 87 87 87 95 690V [kw] 38 38 38 38 78 78 75 75 20 20 20 3 Maximum Operating Rate [ops/ hour],000,000,000,000,000,000 300 600 600 600 600 Continuous Current (UL/CS) General Purpose Rating (40 ) Open [] 25 25 30 30 55 60 75 75 90 90 00 20 Enclosed [] 25 25 30 30 55 60 75 75 90 90 00 20 Maximum Operating Rate [ops/ hour],400,400,200,200,200,000 000 000 700 700 600 600 Lighting Loads ➊ Elec.Dischrg.Lamps-C-5a, Open [] 22.5 25 28 29 40.5 45 77 77 8 85 90 5 single compensated Enclosed [] 22.5 25 28 29 37 4 57 57 57 8 90 00 Max. capacitance at prospective 0k short circuit current available at 20k the contactor 50k [mf] [mf] [mf],000 500 200,000 500 200,000 500 200,000 500 200 Incandescent Lamps - C -5b Electrical endurance ~ 00,000 operations [] 2 6 8 22 30 37 43 5 60 70 76 90 Switching power transformers C-6a 50Hz Inrush = n Rated transformer current [] 0.9 0.9 0.9 0.9 20 20 23 23 40.8 40.8 40.8 48.5 n=30 230 VC [kv] 4.3 4.3 4.3 4.3 8 8 9.2 9.2 6 6 6 9.3 240 VC [kv] 4.5 4.5 4.5 4.5 8.3 8.3 0 0 7 7 7 20.2 380 VC [kv] 7.2 7.2 7.2 7.2 3.2 3.2 5.4 5.4 26.9 26.9 26.9 3.9 400 VC [kv] 7.5 7.5 7.5 7.5 4 4 6 6 28 28 28 33.6 45 VC [kv] 7.8 7.8 7.8 7.8 4 4 7 7 29 29 29 34.9 500 VC [kv] 9.4 9.4 9.4 9.4 7 7 20 20 35 35 35 42 690 VC [kv] 3 3 3 3 24 24 27 27 49 49 49 58 [] 6.3 6.3 6.3 6.3 30 30 34.5 34.5 6.3 6.3 6.3 72.8 n=20 230 VC [kv] 6.5 6.5 6.5 6.5 2 2 4 4 24.4 24.4 24.4 29.0 240 VC [kv] 6.8 6.8 6.8 6.8 2.5 2.5 4.6 4.6 25.5 25.5 25.5 30.3 380 VC [kv] 0.7 0.7 0.7 0.7 9.7 9.7 23.2 23.2 40.3 40.3 40.3 47.9 400 VC [kv].3.3.3.3 20.8 20.8 24.4 24.4 42.5 42.5 42.5 50.4 45 VC [kv].7.7.7.7 2.6 2.6 25.3 25.3 44. 44. 44. 52.3 500 VC [kv] 4. 4. 4. 4. 26 26 30.5 30.5 53. 53. 53. 63.0 690 VC [kv] 9.5 9.5 9.5 9.5 35.9 35.9 42. 42. 73.3 73.3 73.3 86.9 [] 2.7 2.7 2.7 2.7 40 40 46 46 8.7 8.7 8.7 97.0 n=5 230 VC [kv] 8.7 8.7 8.7 8.7 5.9 5.9 8.7 8.7 32.5 32.5 32.5 38.6 240 VC [kv] 9 9 9 9 6.6 6.6 9.5 9.5 33.9 33.9 33.9 40.3 380 VC [kv] 4.3 4.3 4.3 4.3 26.3 26.3 30.9 30.9 53.8 53.8 53.8 63.8 400 VC [kv] 5. 5. 5. 5. 27.7 27.7 32.5 32.5 56.6 56.6 56.6 67.2 45 VC [kv] 5.6 5.6 5.6 5.6 28.8 28.8 33.7 33.7 58.7 58.7 58.7 69.7 500 VC [kv] 8.8 8.8 8.8 8.8 34.6 34.6 40.6 40.6 70.7 70.7 70.7 84.0 690 VC [kv] 26 26 26 26 47.8 47.8 56. 56. 97.6 97.6 97.6 5.9 2,700,350 540 2,700,350 540 3,200,600 640 3,200,600 640 4,000 2,000 800 4,000 2,000 800 4,700 2,350 940 4,700 2,350 940 C7 Contactors ➊ C7 ratings for lighting loads are provided for technical reference. For cul rated and labeled devices, see CL7 contactors listed in this section. 6

C7 Contactors Electrical Data Technical Information C7 3-Pole Contactors C-6a C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 Switching power transformers - 60Hz Inrush = n Rated transformer current [] 0.9 0.9 0.9 0.9 20 20 23 23 40.8 40.8 40.8 48.5 n=30 200 VC [kv] 3.8 3.8 3.8 3.8 6.9 6.9 8.0 8.0 4. 4. 4. 6.8 208 VC [kv] 3.9 3.9 3.9 3.9 7.2 7.2 8.3 8.3 4.7 4.7 4.7 7.5 240 VC [kv] 4.5 4.5 4.5 4.5 8.3 8.3 9.6 9.6 7 7 7 20.2 480 VC [kv] 9. 9. 9. 9. 6.6 6.6 9. 9. 33.9 33.9 33.9 40.3 600 VC [kv].3.3.3.3 20.8 20.8 23.9 23.9 42.4 42.4 42.4 50.4 660 VC [kv] 2.5 2.5 2.5 2.5 22.9 22.9 26.3 26.3 46.6 46.6 46.6 55.4 [] 6.3 6.3 6.3 6.3 30 30 34.5 34.5 6.3 6.3 6.3 72.8 n=20 200 VC [kv] 5.6 5.6 5.6 5.6 0.4 0.4 2 2 2.2 2.2 2.2 25.2 208 VC [kv] 5.9 5.9 5.9 5.9 0.8 0.8 2.4 2.4 22. 22. 22. 26.2 240 VC [kv] 6.8 6.8 6.8 6.8 2.5 2.5 4.3 4.3 25.5 25.5 25.5 30.3 480 VC [kv] 3.6 3.6 3.6 3.6 24.9 24.9 28.7 28.7 5 5 5 60.5 600 VC [kv] 6.9 6.9 6.9 6.9 3.2 3.2 35.9 35.9 63.7 63.7 63.7 75.7 660 VC [kv] 8.6 8.6 8.6 8.6 34.3 34.3 39.4 39.4 70. 70. 70. 83.2 [] 22 22 22 22 40 40 46 46 82 82 82 97 n=5 200 VC [kv] 7.5 7.5 7.5 7.5 3.9 3.9 5.9 5.9 28.4 28.4 28.4 33.6 208 VC [kv] 7.8 7.8 7.8 7.8 4.4 4.4 6.6 6.6 29.5 29.5 29.5 34.9 240 VC [kv] 9 9 9 9 6.6 6.6 9. 9. 34. 34. 34. 40.3 480 VC [kv] 8. 8. 8. 8. 33.3 33.3 38.2 38.2 68.2 68.2 68.2 80.6 600 VC [kv] 22.6 22.6 22.6 22.6 4.6 4.6 47.8 47.8 85.2 85.2 85.2 00.8 660 VC [kv] 24.9 24.9 24.9 24.9 45.7 45.7 52.6 52.6 93.7 93.7 93.7 0.9 C-6b ➊ Capacitor Switching - 50Hz Single Capacitor - 40 C 230 VC [kvar] 8 8 8.5 9 4 4 24 24 28 28 28 28 240 VC [kvar] 8 8 8.5 9 4 4 25 25 29 29 29 29 400 VC [kvar] 8 8 0 2.5 20 24 35 35 48 48 48 48 45 VC [kvar] 8 8 0 2.5 20 25 35 35 50 50 50 50 500 VC [kvar] 8 8 0 2.5 20 25 35 35 50 55 60 60 690 VC [kvar] 8 8 0 2.5 20 25 35 35 50 55 60 60 Single Capacitor - 60 C 230 VC [kvar] 8 8 8.5 9 2.5 2.5 8 8 28 28 28 28 240 VC [kvar] 8 8 8.5 9 2.5 2.5 8 8 29 29 29 29 400 VC [kvar] 8 8 0 2.5 20 2.5 30 30 42 48 48 48 45 VC [kvar] 8 8 0 2.5 20 22 30 30 42 50 50 50 500 VC [kvar] 8 8 0 2.5 20 25 30 30 42 50 55 55 690 VC [kvar] 8 8 0 2.5 20 25 30 30 42 50 55 55 Capacitor Bank - 40 C 230 VC [kvar] 5 5 8 9 2.5 4 20 20 28 28 28 28 240 VC [kvar] 5 5 8 9 2.5 4 20 20 29 29 29 29 400 VC [kvar] 5 5 8 0 5 20 25 25 40 48 48 48 45 VC [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 500 VC [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 690 VC [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 Capacitor Bank - 60 C 230 VC [kvar] 5 5 8 9 2.5 2.5 8 8 28 28 28 28 240 VC [kvar] 5 5 8 9 2.5 2.5 8 8 29 29 29 29 400 VC [kvar] 5 5 8 0 5 20 25 25 40 48 48 48 45 VC [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 500 VC [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 690 VC [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 Capacitor Switching - 60Hz Single Capacitor - 40 C 200 VC [kvar] 5 5 8 9 2.5 4 20 20 28 28 28 28 230 VC [kvar] 5 5 8 9 2.5 4 20 20 29 29 29 29 460 VC [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 600 VC [kvar] 5 5 8 0 5 20 25 25 40 50 60 60 Capacitor Bank - 40 C 200 VC [kvar] 5 5 8 9 2.5 2.5 8 8 28 28 28 28 230 VC [kvar] 5 5 8 9 2.5 2.5 8 8 29 29 29 29 460 VC [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 600 V [kvar] 5 5 8 0 5 20 25 25 40 50 50 50 ➊ Inductance of leads between capacitors in parallel: min. 6 µh (C7-9 C7-30 = L min. 30 µh) 62

Technical Information C7 3-Pole Contactors Electrical Data C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 Switching of Low Inductive Loads in Home ppliances and Similar pplications per IEC 6095 (50 Hz) C-7a 230 VC [] 32 32 32 32 45 45 63 63 ~ ~ ~ ~ 400 VC [] 32 32 32 32 45 45 63 63 ~ ~ ~ ~ 440 VC [] 32 32 32 32 45 45 63 63 ~ ~ ~ ~ Switching of Motor Load Home ppliances - 50 Hz C-7b 230 VC [] 0.5 4 9 23 30 ~ ~ ~ ~ ~ ~ ~ 400 VC [] 9 2 6 20 30 ~ ~ ~ ~ ~ ~ ~ 440 VC [] 7.5 0 3.5 8 27 ~ ~ ~ ~ ~ ~ ~ Switching of Hermetically Sealed Cooling Compressor Motors - 50 Hz C-8a manual reset of overload release 400 VC [] 2 6 22 32 38 45 63 63 72 85 00 5 500 VC [] 2 6 22 32 38 45 63 63 72 85 00 5 690 VC [] 8 0 4 20 28 35 42 42 56 67 80 90 C-8b automatic reset of overload release 400 VC [] 5.5 7 9.3 2 3 4 6 6 24 30 35 35 500 VC [] 5.5 7 9.3 2 3 4 6 6 24 30 35 35 690 VC [] 5.5 7 9.3 2 3 4 6 6 24 30 35 35 C7 Contactors 63

C7 Contactors Electrical Data Technical Information C7 3-Pole Contactors DC- Switching - 60 C C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 24VDC [] 25 25 32 32 45 45 50 50 70 80 80 80 48VDC [] 20 20 20 20 25 25 30 30 40 40 40 40 Pole 60VDC [] 20 20 20 20 25 25 30 30 40 40 40 40 0VDC [] 6 6 6 6 8 8 9 9 220VDC [].5.5.5.5.5.5.5.5 2 2 2 2 440VDC [] 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.5 24VDC [] 25 25 32 32 45 45 50 50 70 80 80 80 48VDC [] 25 25 32 32 45 45 50 50 70 80 80 80 2 Poles in Series 60VDC [] 25 25 32 32 45 45 50 50 70 80 80 80 0VDC [] 25 25 32 32 45 45 50 50 70 80 80 80 220VDC [] 8 8 8 8 0 0 0 0 5 5 5 5 440VDC [].5.5.5.5 24VDC [] 25 25 32 32 45 45 63 63 90 90 00 00 48VDC [] 25 25 32 32 45 45 63 63 90 90 00 00 3 Poles in Series 60VDC [] 25 25 32 32 45 45 63 63 90 90 00 00 0VDC [] 25 25 32 32 45 45 63 63 90 90 00 00 220VDC [] 25 25 32 32 45 45 50 50 70 80 80 80 440VDC [] 3 3 3 3 3.5 3.5 4 4 5 5 5 5 DC-2, 3, 5 Switching - 60 C Starting, reverse current braking, reversing, DC-5, 60ºC 24VDC [] 25 25 32 32 45 45 63 63 90 90 00 00 48VDC [] 25 25 32 32 45 45 50 50 70 70 80 80 60VDC [] 25 25 32 32 45 45 50 50 70 70 80 80 Shunt Wound 0VDC [] 20 20 25 25 30 30 35 35 70 70 80 80 3 Poles in Series 220VDC [] 6 6 6 0 5 5 20 20 25 25 30 30 440VDC [] 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 Series-wound Motors 3 Poles in Series 24VDC [] 25 25 32 32 45 45 63 63 90 90 00 00 48VDC [] 25 25 32 32 45 45 50 50 70 70 80 80 60VDC [] 25 25 32 32 45 45 50 50 70 70 80 80 0VDC [] 20 20 25 25 30 30 35 35 70 70 80 80 220VDC [] 6 6 6 0 5 5 20 20 25 25 30 30 440VDC [] 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 Three poles wired in series for DC switching + OPTION OPTION B 64

Electrical Data Technical Information C7 3-Pole Contactors C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 Resistance and Watt Loss I e C-3/ 400V Resistance per power pole [mω] 2.7 2.7 2.7 2.0 2.0 2.0.5.0 0.9 0.9 0.9 0.6 Watt Loss - 3 power poles [W] 0.66.2 2. 3.2 5.4 8.2 8.3 9. 9.7 4.0 9.5 7 Coil and 3 power poles C (coil warm) [W] 3.4 3.9 4.8 6.3 8.5.3.6 2.4 6.2 8 23.5 26 DC (coil warm) [W] 2.4 2.9 3.8 4.9 7. 9.9 0.8.6 3.7 8 23.5 22 Short-Circuit Coordination Max. Fuse or circuit breaker ratings DIN Fuses -gg, gl vailable Fault Current [K] 50 50 50 50 50 50 50 50 50 50 50 50 Type (690V) ➌ [] 50 50 50 80 25 25 60 60 250 250 250 250 Type 2 (690V) ➌ [] 25 35 35 40 80 80 00 00 60 60 60 200 BS 88 Fuses vailable Fault Current [K] 65 65 65 65 65 65 65 ➍ 65 65 65 ➍ Type (45V) ➌ [] 25 32 40 50 63 80 80 ➍ 00 60 60 ➍ Type 2 (45V) ➌ [] 20 25 32 50 63 80 80 ➍ 00 25 60 ➍ C7 Contactors cul Short-Circuit Ratings Class K, RK, K5, and RK5 Fuses vailable Fault Current [K] 5 5 5 5 5 5 5 5 5 0 0 0 cul Max. Rating (600V) ➋ Type [] 35 40 70 90 0 25 50 200 200 250 300 350 Class CC & CS HRCI Fuses vailable Fault Current [K] 00 00 00 00 ~ ~ ~ ~ ~ ~ ~ ~ cul Max. Rating (600V) ➋ Type 2 [] 5 20 30 40 ~ ~ ~ ~ ~ ~ ~ ~ Class J CS & HRCI-J Fuses vailable Fault Current [K] 00 00 00 00 00 00 00 00 00 00 00 00 cul Max. Rating (600V) Type 2 [] 5 20 30 40 50 50 70 70 80 00 50 75 Inverse-Time Circuit Breaker ➊ vailable Fault Current [K] 5 5 5 5 5 5 5 5 5 0 0 0 cul Max. Rating 480V ➋ Type [] 30 30 50 50 25 25 25 50 250 250 250 250 cul Max. Rating 600V ➋ Type [] ~ ~ ~ ~ 25 25 25 50 250 250 250 250 Short Time Current Withstand Ratings I cw 60 C 0 s [] 70 70 70 25 300 304 375 375 700 700 700 840 Off Time Between Operations [Min.] 20 20 20 20 20 20 20 20 20 20 20 20 ➊ When used as a Branch Circuit Protection device, NEC 430-52 defines the maximum rating of an Inverse-time circuit breaker to be sized at 250% of the motor nameplate FL for most applications. ➋ UL Listed Combination. (UL File E4850) Per UL508, NEC409 abd CS 22.2 No.4 for contactor and fuses or circuit breaker only. ➌ Per IEC 60947- for contactor and fuses only. ➍ To be determined - Test data not available at time of this printing. 65

C7 Contactors Short Circuit Ratings High Fault Short Circuit Ratings per UL508 and CS 22.2 No.4 CEP7 Second Generation Cat. No. CEP7 Contactor Cat. No. Max. starter FLC () Max. available fault current (k) Fuse Ratings Max. voltage (V) UL Class J/CC/ CS HRCI-J fuse max. () 3 Technical Information C7 Contactors & Overload Relay UL Listed Circuit Breaker Ratings Short Circuit Rating (k) Max. voltage (V) Max. CB Rating () EDB, EEB 0.5 C7-9 EDBB, EEBB 6 5 480 30 C7-9 09 00 600 20 ~ 600 ~ C7-2 EDCB, EDDB, 2 20 CN7-2 EDEB, EEEB, C7-6 EECB, EEDB 6 30 5 480 50 CN7-6 00 600 ~ 600 ~ C7-23 23 30 C7-30 30 50 EDDD, EDED, C7-37 50 37 50 65 480 EDFD, EEDD, CN7-37 00 600 25 600 EEED, EEFD C7-43 43 70 80 CN7-43 CEP7-EEQD C7-55 55 00 600 70 EEEE, EEFE EEGE C7-60 60 80 C7-72 72 00 00 600 C7-85 85 50 CN7-85 EEVE C7-97 97 00 600 75 65 25 65 25 65 25 480 600 480 600 480 600 80 25 25 25 25 66

Short Circuit Ratings Standard Fault Short Circuit Ratings per UL508 and CS 22.2 No.4 Max. available CEP7 Second Generation fault current Cat. No. (k) CEP7 Conditional S.C. current, Iq (k) S.C.P.D. EDB, EEB, EDBB, EEBB Suitable for use with fuses only EDCB, EDDB, EDEB, EDDD, EDED, EDFD EECB, EEDB, EEEB, EEDD, EEED, EEFD, EEQD EEPB, EERB, EESB, EETD 5 600V Max. Voltage Not restricted to fusing only EEEE, EEFE, EEGE, EEUE, EEVE 0 Technical Information C7 Contactors & Overload Relay C7 Contactors IEC Short Circuit Ratings per EN60947-4- CEP7 Second Generation Cat. No. EDB, EEB EDBB, EEBB CEP7 EDCB, EDDB, EECB, EEDB, EEPB, EERB EDEB, EDDD, EDED, EDFD, EEEB, EEDD, EEED, EEFD, EEQD, EEEE, EEFE, EESB, EETD 3 EEGE, EEUE, EEVE 5 Prospective S.C. Conditional S.C. current, Ir (k) current, Iq (k) Max. voltage (V) 00 690 S.C.P.D. Suitable for use with fuses only Not restricted to fusing only IEC Type I and Type II Fuse Coordination with C7 Series contactors per EN60947-4- CEP7 Second Generation Cat. No. CEP7 Contactor Cat. No. Prospective S.C. current/ Ir (k) Conditional S.C. current/ Iq (k) Type I with Class J fuse max. () Type II with Class J fuse max. () Max. starter Max. voltage FLC () (V) EDB, EEB 0.5 3 3 C7-9 EDBB, EEBB 6 6 EDCB, EDDB, EECB, EEDB EDEB, EEEB EDDD, EDED, EDFD, EEDD, EEED, EEFD C7-9 9 20 5 C7-2 2 20 20 C7-6 6 30 30 C7-23 23 30 30 C7-9 9 20 5 00 600 C7-2 2 20 20 3 C7-6 6 30 30 C7-23 23 30 30 C7-30 30 50 50 C7-37 37 50 50 3 C7-43 43 70 70 EEQD C7-55 55 70 70 EEEE, EEFE EEGE C7-60 60 C7-72 72 3 00 00 00 600 80 80 C7-85 85 50 50 C7-60 60 80 80 C7-72 72 00 00 5 C7-85 85 50 50 EEVE C7-97 97 75 75 67

C7 Contactors Electro-Mechanical Data Technical Information C7 3-Pole Contactors C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-55 C7-60 C7-72 C7-85 C7-97 Service Life Mechanical C [Mil.] 3 3 3 3 3 3 2 2 6 6 6 6 DC [Mil.] 3 3 3 3 3 3 3 3 6 6 6 6 Electrical C-3 (400V) C [Mil.].3.3.3.3.3.3.0 0.8.0.0.0.0 Shipping Weights C - C7 [kg] 0.39 0.39 0.39 0.39 0.48 0.49 0.5 0.5.45.45.45.45 [Lbs.] 0.86 0.86 0.86 0.86.06.08.2.2 3.20 3.20 3.20 3.20 C -CU7 [kg] 0.85 0.85 0.85 0.85.08.08.5.5 3.4 3.4 3.4 3.4 [Lbs.].89.89.89.89 2.39 2.39 2.54 2.54 6.92 6.92 6.92 6.92 DC - C7 [kg] 0.4 0.4 0.4 0.4 0.45 0.45 0.60 0.60.47.47.47.47 [Lbs.] 0.90 0.90 0.90 0.9.00.00.32.32 3.24 3.24 3.24 3.24 DC - CU7 [kg] 0.89 0.89 0.89 0.90 0.98 0.98.33.33 3.22 3.22 3.22 3.22 [Lbs.].97.97.97.99 2.7 2.7 3.93 2.93 7.0 7.0 7.0 7.0 Terminations - Power Description One saddleclamp per pole: cross, slotted or Pozidrive No. 2/blade No. 3 screw Dual connection; one saddleclamp and one box lug per pole; cross, slotted or Pozidrive No. 2/blade No. 4 screw Dual connection; two box lugs per pole llen Head: 4mm, 5/32 Wire 2 Wires [mm 2 ] [mm 2 ]...4...4 2.5...6 2.5...0 2.5...35 2.5...25 Wire 2 Wires [mm 2 ] [mm 2 ].5...6.5...6 2.5...25 2.5...6 2.5...50 2.5...35 Torque Requirement Wire 2 Wires [WG] [WG] [Nm] [Lb-in] 6...0 6...0.5...2.0 3.3...7.7 4...4 4...4 2.5...3.5 22...3 4... 4... 4.5...6 40...53 Terminations - Control Description Combination Screw Head: Cross, Slotted, Pozidrive Coils or 2 [mm 2 ] 2.5 Wires [WG] 6 2 Control Modules or 2 [mm 2 ] 4 Wires [WG] 6 2 Torque Requirement [Nm].5 [Lb-in] 8.9 3 C7-9 23: IP2X from all directions Degree of Protection - contactor C7-30 55: IP2X from front with front (upper) terminal wired C7-60 97: IP2X from front with front (upper) terminal wired (min. wire size 6mm 2 or #6 WG) Protection gainst ccidental Contact Safe from touch by fingers and back-of-hand per VDE 006; Part 00 Environmental and General Specifications mbient Temperature ➊ Storage -55...+80 C (-67...76 F) - [CRI7E Electronic Interface -50...+80 C (-58...76 F)] Operation -25...+60 C (-3...40 F) (40 C per UL) Conditioned 5% current reduction after C- at >60 C -25...+70 C (-3...58 F) ltitude at installed site 2000 meters above sea level per IEC 60947- Resistance to Corrosion/Humidity Damp-alternating climate: cyclic to IEC 68-2, 56 cycles Dry heat: IEC 68-2, +00 C (22 F), relative humidity <50%, 7 days. Damp tropical: IEC 68-2, +40 C (04 F), relative humidity <92%, 56 days. Shock Resistance IEC 60068-2-27: Half sinusoidal shock ms, 30g (in all three directions) Vibration Resistance IEC 60068-2-6: Static > 2g, in normal position no malfunction <5g Pollution Degree 3 Operating Position Refer to Dimension Pages Standards IEC/EN 60947-/-4-/-5-; UL508; CS 22.2 No. 4 pprovals CE, culus, CCC ➊ mbient is the temperature outside the enclosure. 68

Lug Kit and Paralleling Link Specifications pprovals Conformity to Standards Protection gainst ccidental Contact Terminations C7-P- KN23 / KL23 Technical Information C7 3-Pole Contactors C7-P-K37 C7-P-K43 C7-P-K85 C7-P-B23 C7-P-B37 UL Listed; CS Certified; C UL508; CS 22.2 No. 4; IEC 60947-4 IP2LX Finger Protection C7 Contactors Description Cross, slotted or Pozidrive screw llen Head; 5mm, 3/6 llen Head; 7 mm, 5/32 Wire Size Wire [mm 2 ] 4...6 4..6 6...35 0...70 35...70 35...70 Wire [mm 2 ] 4...25 4..25 6...50 0...95 35...95 35...95 Wire [WG] 0...4 0...4 8...2 8..2/0 0...2/0 0...2/0 Torque Requirement [Nm] 2...3 2...3 3..6 8...2 6...2 6...2 [Lb-in] 8...27 8...27 27...54 72...08 54...08 54...08 Coil Data - C / Two Winding DC C7-9 2 C7-6 C7-23 C7-30 37 C7-43 55 C7-60 85 C7-97 Voltage Range C: 50Hz, 60Hz, 50/60 Hz Pickup [xu s ] 0.85... Dropout [xu s ] 0.3...0.6 DC: Two Winding (60D 97D) Pickup [xu s ] 0.8... (9V coils = 0.65...3; 24V coils = 0.7...25) Dropout [xu s ] 0...0.6 Coil Consumption C: 50Hz, 60Hz, 50/60 Hz Pickup [V] 75 75 05 05 35 235 400V/240W Hold-in [V/W] 9.5/2.7 9.5/2.7 2.3/3. 2.3/3. 3.3/3.3 9/6.5 24/9 DC: Two Winding (60D 97D) Pickup [W] 200 325 ~ Hold-in [W] 4.5 5.5 Operating Times C: 50Hz, 60Hz, 50/60 Hz Pickup [ms] 5...30 5...30 5...30 5...30 5...30 20...40 20...40 Dropout [ms] 0...60 0...60 0...60 0...60 0...60 0...60 20...40 with RC Suppressor Dropout [ms] 0...60 0...60 0...60 0...60 0...60 0...60 20...40 DC: Two Winding (60D 97D) Pickup [ms] 20...40 5...25 ~ Dropout [ms] 20...35 ➊ 5...25 ➊ Coil Data - Electronic DC Voltage Range Coil Consumption & Operating Times ➋ Voltage Nominal Voltage US Ratings verage/peak Pickup [W] Hold-in [W] Dropout Voltage Pickup Dropout Code [VDC] [xu s ] C7-9E 37E C7-43E 55E C7-9E 37E C7-43E 55E [xu s ] [ms] [ms] 2E 2 0.7.25 0/7 6/25.7 2.5 24E 24 0.7.25 0/7 6/25.7 2.5 0.3 0.4 25 50 27 45 36E 36 48 0.7.25 0/7 6/25.7.9 2.5 2.7 48E 48 72 0.8.25 0/7 6/25.7.9 2.5 2.7 0E 0 25 0.7.2 ➌ 2/9 6/26 2.0 2. 2.7 2.8 0.3 0.4 25 50 23 33 220E 220 250 0.8. 4/22 8/29 2.7 3.0 3.5 4.0 ➊ 220V. ➋ The hold-in demand of the C7-9E 55E is very low but the pick-up demand is approximately ampere at 24 VDC. When sizing (dimensioning) a power supply for applications involving parallel switched contactors then multiply the peak demand by the number of contactors to be simultaneously switched and add to the hold-in demand of all other control circuit burdens, including other contactors, pilot devices, solenoids, etc. ➌ t 0VDC, coil code 0E has an operating range of 0.7.25 xu s 69

Technical Information C7 4-Pole Contactors C7 Contactors Electrical Data Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 UL; CS Rated Impulse Voltage U imp Rated Voltage U e - Main Contacts C 50/60Hz DC Operating Frequency for C Loads C7-9-M40(3; 22) C7-2-M40(3; 22) C7-6-M40(3; 22) C7-23-M40(3; 22) 690V 600V 8 kv 5, 200, 208, 230, 240, 380, 400, 45, 460, 500, 575, 690V 24, 48, 0, 5, 220, 230, 300, 440V 50...60Hz C7-40-M22 C7-40-M40 C7-90-M22 C7-90-M40 Switching Motor Loads Standard IEC Ratings C-2, C-3, C-4 230V [] 2 5 20 26.5 38 38 85 85 DOL & Reversing 240v [] 2 5 20 26.5 38 38 85 85 50Hz/60ºC 400V [] 9 2 6 23. 37 37 85 85 45V [] 9 2 6 23 37 37 85 85 500V [] 7 0 4 20 29 30 80 80 690V [] 5 7 9 2 9 2 22 49 230V [kw] 3 4 5.5 7.5 25 25 240V [kw] 3 4 5.5 7.5 25 25 400V [kw] 4 5.5 7.5 8.5 8.5 45 45 45V [kw] 4 5.5 7.5 8.5 8.5 45 45 500V [kw] 4 5.5 7.5 3 8.5 20 55 55 690V [kw] 4 5.5 7.5 0 7.5 8.5 8.5 45 UL/CS DOL & Reversing 5V [] 7.2 9.8 6 24 34 34 80 80 60Hz/60ºC Ø 230V [] 8 2 7 7 28 28 68 68 5V [HP] /2 /2 2 3 3 7-/2 7-/2 230V [HP] -/2 2 3 3 5 5 5 5 200V [] 7.8 7.5 7.5 32.2 32.2 78.2 78.2 230V [] 6.8 9.6 5.2 22 28 28 80 80 460V [] 7.6 4 2 34 34 65 77 575V [] 9 7 7 7 32 22 52 200V [HP] 2 3 5 5 0 0 25 25 230V [HP] 2 3 5 7-/2 0 0 30 30 460V [HP] 5 7-/2 0 5 25 25 50 60 575V [HP] 7-/2 0 5 5 5 30 20 50 Maximum Operating Rate C2 [ops/hr] 450 450 450 400 400 400 200 200 (at max. amps) C3 [ops/hr] 700 700 700 600 600 600 500 500 C4 [ops/hr] 200 50 20 80 70 70 50 50 70

Electrical Data C7-9-M40 (3; 22) C7-2-M40 (3; 22) C7-6-M40 (3; 22) C7-23-M40 (3; 22) C7-40-M22 C7-40-M40 C7-90-M22 C7-90-M40 C- Load, 3Ø Switching mbient Temperature 40ºC I th [] 32 32 32 32 75 75 30 30 230V [kw] 3 3 3 3 30 30 52 52 240V [kw] 3 3 3 3 3 3 54 54 400V [kw] 22 22 22 22 52 52 90 90 45V [kw] 23 23 23 23 54 54 93 93 500V [kw] 28 28 28 28 65 65 3 3 690V [kw] 38 38 38 38 90 90 55 55 I th [] 32 32 32 32 60 60 0 0 230V [kw] 3 3 3 3 24 24 44 44 mbient Temperature 60º 240V [kw] 3 3 3 3 25 25 46 46 400V [kw] 22 22 22 22 42 42 76 76 45V [kw] 23 23 23 23 43 43 79 79 500V [kw] 28 28 28 28 52 52 95 95 690V [kw] 38 38 38 38 72 72 3 3 Max Operating Rate [ops/hour],000,000,,000,,000 300 300 600 600 Continuous Current (UL/CS) General Purpose Rating (40º) Open [] 25 25 30 30 60 60 25 30 Enclosed [] 25 25 30 30 60 60 25 30 Max. Operating Rate [ops/hour],400,400,200,200,000,000 600 600 Lighting Loads ❶ Technical Information C7 4-pole Contactors Elec. Dischrg.Lamps-C-5a, Open [] 22.5 25 28 29 65 65 5 5 single compensated Enclosed [] 22.5 25 28 29 54 54 95 95 Incandescent Lamps C-5b, Electrical endurance~00,000 operations 2 6 8 22 8 25 60 75 DC- Switching - 60ºC 24VDC [] 25 25 32 32 45 45 80 80 48VDC [] 20 20 20 20 25 25 40 40 Pole 60VDC [] 20 20 20 20 25 30 40 40 0VDC [] 6 6 6 6 0 0 220VDC [].5.5.5.5.5.5.8.8 440VDC [] 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 24VDC [] 25 25 32 32 45 45 80 80 48VDC [] 25 25 32 32 45 45 80 80 2 Pole in Series 60VDC [] 25 25 32 32 45 45 80 80 0VDC [] 25 25 32 32 45 45 80 80 220VDC [] 8 8 8 8 0 0 5 5 440VDC [].5.5 24VDC [] 25 25 32 32 ~ 48 ~ 00 48VDC [] 25 25 32 32 ~ 48 ~ 00 3 Poles in Series ➋ 60VDC [] 25 25 32 32 ~ 48 ~ 00 0VDC [] 25 25 32 32 ~ 48 ~ 00 220VDC [] 25 25 32 32 ~ 48 ~ 80 440VDC [] 3 3 3 3 ~ 3.5 ~ 5 24VDC [] 25 25 32 32 ~ 60 ~ 0 48VDC [] 25 25 32 32 ~ 60 ~ 0 4 Poles in Series 60VDC [] 25 25 32 32 ~ 60 ~ 0 0VDC [] 25 25 32 32 ~ 60 ~ 0 220VDC [] 25 25 32 32 ~ 60 ~ 00 440VDC [] 8 8 8 8 ~ 0 ~ 5 C7 Contactors ➊ C7 ratings for lighting loads are provided for technical reference. For cul rated and labeled devices, see CL7 contactors listed in this section. ➋ See page 64 for Three poles wired in series for DC switching 7

C7 Contactors Electrical Data C7-9-M40 (3; 22) C7-2-M40 (3; 22) C7-6-M40 (3; 22) C7-23-M40 (3;22) Technical Information C7 4-pole Contactors C7-40-M22 C7-40-M40 C7-90-M22 C7-90-M40 Resistance and Watt Loss I e C-3/ 400V Resistance per power pole [mω] 2.7 2.7 2.7 2.0 2.0.5 0.8 0.7 Watt Loss - 4 power poles [W] 0.66.2 2. 3.2.3 8.4 3.5.8 Coil and 4 power poles C [W] 3.4 3.9 4.8 6.3 8.8 9.5 36 56.3 DC [W] 2.4 2.9 3.8 4.9 8 8.7 32.5 52.8 Short Circuit Coordination DIN Fuses -gg, gl vailable Fault Current [] 00 K 00 K 00 K 00 K 50 K 50 K 50 K 50 K Type (690V) ➌ [] 50 50 50 80 60 60 250 250 Type 2 (690V) ➌ [] 25 35 35 40 00 00 60 60 BS 88 Fuses vailable Fault Current [] 80 K 80 K 80 K 80 K ~ ~ ~ ~ Type (690V) ➌ [] 25 32 35 50 ~ ~ ~ ~ Type 2 (690V) ➌ [] 25 32 35 50 ~ ~ ~ ~ Class K, RK Fuses vailable Fault Current [] 00 K 00 K 00 K 00 K 00 K 00 K 00 K 00 K Type 2 (600V) ➌ [] 5 20 20 30 70 70 00 00 cul Short-Circuit Ratings Class K, RK, K5, and RK5 Fuses vailable Fault Current [] 5 K 5 K 5 K 5 K 5 K 5 K 0 K 0 K cul Max. Rating (600V) ➋ Type [] 35 40 70 90 25 25 300 300 Class CC & CS HRCI Fuses vailable Fault Current [] 00 K 00 K 00 K 00 K ~ ~ ~ ~ cul Max. Rating (600V) ➋ Type 2 [] 5 20 30 30 ~ ~ ~ ~ Class J CS & HRCI-J Fuses vailable Fault Current [] 00 K 00 K 00 K 00 K 00 K 00 K 00 K 00 K cul Max. Rating (600V) ➋ Type 2 [] 5 20 30 30 70 ➍ 70 ➍ 50 ➍ 50 ➍ Inverse-Time Circuit Breaker ➊ vailable Fault Current [] 5 K 5 K 5 K 5 K 5 K 5 K 0 K 0 K cul Max. Rating 480V ➋ Type [] 30 30 50 50 25 25 250 250 cul Max. Rating 600V ➋ Type [] ~ ~ ~ ~ 25 25 250 250 Short Time Current Withstand Ratings I cw 60 C [] 70 70 70 25 304 304 700 700 Off Time Between Operations [Min.] 20 20 20 20 5 5 5 5 ➊ When used as a Branch Circuit Protection device, NEC 430-52 defines the maximum rating of an Inverse-time circuit breaker to be sized at 250% of the motor nameplate FL for most applications. ➋ UL Listed Combination. (UL File E4850) Per UL508, NEC409 abd CS 22.2 No.4 for contactor and fuses or circuit breaker only. ➌ Per IEC 60947- for contactor and fuses only. ➍ UL Testing not complete a the time of printing this catalog. 72

Mechanical Data C7-9-M40 (3; 22) C7-2-M40 (3; 22) C7-6-M40 (3; 22) C7-23-M40 (3; 22) CL7-20 C7-40-M22 C7-40-M40 CL7-30 C7-90-M22 C7-90-M40 CL7-60 Service Life Mechanical C [Mil.] 3 3 3 3 0 0 0 0 Shipping Weights DC [Mil.] 3 3 3 3 0 0 0 0 C - C7 [kg] 0.39 0.39 0.39 0.39 0.5 0.5.45.45 [Lbs.] 0.86 0.86 0.86 0.86.2.2 3.20 3.20 DC - C7 [kg] 0.4 0.4 0.4 0.4 0.59 0.59.47.47 Terminations - Power Description Technical Information C7 4-pole Contactors [Lbs.] 0.90 0.90 0.90 0.9.30.30 3.24 3.24 C7 Contactors One saddleclamp per pole: cross, slotted or Pozidrive No. 2/blade No. 3 screw Dual connection; one saddleclamp and one box lug per pole; cross, slotted or Pozidrive No. 2/ blade No. 4 screw Dual connection; two box lugs per pole llen Head: 4mm, 5/32 Wire 2 Wires [mm 2 ] [mm 2 ]...4...4...4...4...4...4...4...4 2.5...0 2.5...0 2.5...0 2.5...0 2.5...6 2.5...0 2.5...35 2.5...25 Wire 2 Wires [mm 2 ] [mm 2 ].5...6.5...6.5...6.5...6.5...6.5...6.5...6.5...6 2.5...6 2.5...6 2.5...6 2.5...6 2.5...25 2.5...6 2.5...50 2.5...35 Wire 2 Wires [WG] [WG] 6...0 6...0 6...0 6...0 6...0 6...0 6...0 6...0 4...6 4...6 4..6 4..6 4...4 4...4 4... 4... Torque Requirement [Nm] [Lb-in].5...2.0 3.3 7.7.5...2.0 3.3 7.7.5...2.0 3.3 7.7.5...2.0 3.3 7.7 2.5...3.5 22...3 2.5...3.5 22...3 3.5...6 3...52 3.5...6 3...52 Terminations - Control Description Combination Screw Head: Cross, Slotted, Pozidrive Coils or 2 [mm 2 ] 2.5 Wires [WG] 6 2 Control Modules or 2 [mm 2 ] 4 Wires [WG] 6 2 Torque Requirement [Nm].5 [Lb-in] 8.9 3 C7-9 23: IP2X from all directions Degree of Protection - contactor C7-30 55: IP2X from front with front (upper) terminal wired C7-60 97: IP2X from front with front (upper) terminal wired (min. wire size 6mm 2 or #6 WG) Protection gainst ccidental Contact Safe from touch by fingers and back-of-hand per VDE 006; Part 00 Environmental and General Specifications mbient Temperature ➊ Storage -55...+80 C (-67...76 F) - [CRI7E Electronic Interface -50...+80 C (-58...76 F)] Operation -25...+60 C (-3...40 F) (40 C per UL) Conditioned 5% current reduction after C- at >60 C -25...+70 C (-3...58 F) ltitude at installed site 2000 meters above sea level per IEC 60947- Resistance to Corrosion/Humidity Damp-alternating climate: cyclic to IEC 68-2, 56 cycles Dry heat: IEC 68-2, +00 C (22 F), relative humidity <50%, 7 days. Damp tropical: IEC 68-2, +40 C (04 F), relative humidity <92%, 56 days. Shock Resistance IEC 60068-2-27: Half sinusoidal shock ms, 30g (in all three directions) Vibration Resistance IEC 60068-2-6: Static > 2g, in normal position no malfunction <5g Pollution Degree 3 Operating Position Refer to Dimension Pages Standards IEC/EN 60947-/-4-/-5-; UL508; CS 22.2 No. 4 pprovals CE, culus, CCC ➊ mbient is the temperature outside the enclosure. 73

C7 Contactors Coil Data - C / Two Winding DC C7-9-M40 (3; 22) C7-2-M40 (3; 22) C7-6-M40 (3; 22) C7-23-M40 (3; 22) CL7-20 C7-40-M22 C7-40-M40 CL7-30 Technical Information C7 4-Pole Contactors C7-90-M22 C7-90-M40 CL7-60 Voltage Range C: 50Hz, 60Hz, 50/60 Hz Pickup [xu s ] 0.85... Dropout [xu s ] 0.3...0.6 DC, Two Winding (90D) Pickup [xu s ] 0.8... (9V coils = 0.65...3; 24V coils = 0.7...25) Dropout [xu s ] 0...0.6 Coil Consumption C: 50Hz, 60Hz, 50/60 Hz Pickup [V] 75 75 75 05 35 35 400V/240W 400V/240W Hold-in [V/W] 9.5/2.7 9.5/2.7 9.5/2.7 2.3/3. 3.3/3.3 3.3/3.3 24/9 24/9 DC: Two Winding (90D) Pickup [W] ~ ~ ~ ~ ~ ~ 325 325 Hold-in [W] ~ ~ ~ ~ ~ ~ 5.5 5.5 Operating Times C: 50Hz, 60Hz, 50/60 Hz Pickup [ms] 5...30 5...30 5...30 5...30 5...30 5...30 20...30 20...40 Dropout [ms] 0...60 0...60 0...60 0...60 0...60 0...60 20...40 20...40 with RC Suppressor Dropout [ms] 0...60 0...60 0...60 0...60 0...60 0...60 20...40 20...40 DC: Two Winding (90D) Pickup [ms] ~ ~ ~ ~ ~ ~ 5...20 5...25 Dropout [ms] ~ ~ ~ ~ ~ ~ 20...25 5...25 Coil Data - Electronic DC Voltage Range Coil Consumption & Operating Times ➋ Voltage Nominal Voltage US Ratings verage/peak Pickup [W] Hold-in [W] Dropout Voltage Pickup Dropout Code [VDC] [xu s ] C7-9E 37E C7-40E C7-9E 37E C7-40E [xu s ] [ms] [ms] 2E 2 0.7.25 0/7 6/25.7 2.5 24E 24 0.7.25 0/7 6/25.7 2.5 0.3 0.4 25 50 27 45 36E 36 48 0.7.25 0/7 6/25.7.9 2.5 2.7 48E 48 72 0.8.25 0/7 6/25.7.9 2.5 2.7 0E 0 25 0.7.25 2/9 6/26 2.0 2. 2.7 2.8 0.3 0.4 25 50 23 33 220E 220 250 0.7. 4/22 8/29 2.7 3.0 3.5 4.0 ➊ The hold-in demand of the C7-9E 55E is very low but the pick-up demand is approximately ampere at 24 VDC. When sizing (dimensioning) a power supply for applications involving parallel switched contactors then multiply the peak demand by the number of contactors to be simultaneously switched and add to the hold-in demand of all other control circuit burdens, including other contactors, pilot devices, solenoids, etc. 74

Technical Information uxiliary Contact Data Mounted Standard uxiliary Built-in uxiliary Contacts in Contactor C7-9... C7-23 Front Mounted uxiliary Contacts C7-PV, CS7-PV, CZE/7, CV7 Technical Information Front Mounted Bifurcated uxiliary Contacts C7 Contactors Side Mounted uxiliary Contacts C-P, CM7 Electrical Contact Ratings - NEM 600, P600 600, Q600 600, Q600 Min. Contact Rating 7V, 0 m 7V, 5 m 5V, 3 m 7V, 0 m 24V 0 6 3 6 48V 0 6 3 6 20V 0 6 3 6 Contact Ratings - IEC C-5 (solenoids, 240V 0 5 3 5 contactors) rated voltage IEC 60947-5- 400V 6 3 2 3 480V/500V 2.5.6.2.6 600V 0.7 690V 0.7 C-2 (Control of resistive loads) IEC 60947-5- DC-2 Switching DC Loads L / R < ms, Resistive Loads IEC 60947-5- 40 ºC 60 ºC DC-3 IEC 60947-5-, Solenoids and contactors I th 20 0 0 0 230V 8 kw 400V 4 kw 690V 24 kw I th 20 6 6 6 230V 8 kw 400V 4 kw 690V 24 kw 24V 2 2 6 6 48V 9 9 3.2 3.2 0V 3.5 3.5 0.45 0.45 220V 0.55 0.55 0.8 0.8 440V 0.2 0.2 0. 0. 24V 5 5 2.5 5 48V 3 3.5 3 0V.2.2 0.6.2 220V 0.6 0.6 0.3 0.6 440V 0.3 0.5 0.5 0.5 C7 Contactors Terminal Marking Information for Built In uxiliary Contacts C7-9 23-0 Typical C7-9 23-0 Typical C7-30...97 Typical Side Mount uxiliary 75

C7 Contactors uxiliary Contacts Built-in uxiliary Contacts in Contactor C7-9...C7-23 Front Mounted uxiliary Contacts C7-PV, CS7-PV, CZE/7, CV7 Technical Information C7 Contactors Side Mounted uxiliary Contacts C-P, CM7 Continuous Current Rating per UL/CS Rated Voltage C [V] 600 max. 600 max. 600 max. Continuous Rating 40 C [] 0 general purpose 0 general purpose 0 general purpose Heavy pilot duty (600) Heavy pilot duty (600) Heavy pilot duty (600) Continuous Rating DC [] 5, 600 max. 2.5, 600 max. 2.5, 600 max. Standard pilot duty (P600) Standard pilot duty (Q600) Standard pilot duty (Q600) Short-Circuit Protection -ggfuse Type 2 Coordination [] 20 0 0 Rated Impulse Voltage U imp [kv] 8 8 6 Insulation Voltage (between control and load circuit) per DIN< VDE 003, Part 0 (NMUR recommendation) [V] 380 440 440 Mechanically Linked Contacts (per IEC60947-5- ➊nnex L (SUV Third-party certified) Terminals Mutually unrestricted between all NO and NC contacts Mutually unrestricted between all NO & NC contacts. CZE & CV7 not mechanically linked with contactor main contacts Mutually unrestricted between all NO and NC contacts Terminal Type Maximum Wire Size per IEC 947-2x4 2x4 2x4 Flexible conductor [mm 2 ]...4 0.5...2.5 0.5...2.5 with Wire-End Fernule 2 conductor [mm 2 ]...4 0.75...2.6 0.75...2.6 Solid/Stranded- conductor [mm 2 ].5...6 0.5...2.5 0.5...2.5 Conductor 2 conductor [mm 2 ].5...6 0.75...2.6 0.75...2.6 Recommended Tightening Torque [Nm].5...2.5...5...5 Max. Wire Size per UL/CS [WG] 6...0 6...2 6...2 Recommended Tightening Torque [lb-in] 3...22 8.9...3 8.9...3 ccessories Latch ttachment Release, CV7- Coil Consumption [V/W] C 45/40 [W] DC 25W Contact Signal Duration [min/max] 0.03...5s Time ttachment Reset Time at min. time setting [ms] 0 at max. time setting [ms] 70 Repeat ccuracy ±0% Contact Ratings (Per NEM/UL 600 & Q600) Standard 600 Q600 Circuit Voltage 20C 240C 480C 600C 25DC 250DC 30-600DC Make (mps/v) 60/7200V 30/7200V 5/7200V 2/7200V 0.55/69V 0.27/69V 0./69V Break (mps/v 6/720V 3/720V.5/720V.2/720V 0.55/69V 0.27/69V 0./69V Continuous mps 0 25 Positively-Guided Contacts ( Mechanically-linked) SUV Certified Restricted guidance guarantees without restrictions from contactor to auxiliary contact and auxiliary contact to contactor.➊ ➊ See Section G for additional details. 76

Technical Information C7 Contactors Life Load Curves Life-Load Curves Locate the Rated Operational Current (l e ) along the bottom of the chart and follow the graph lines up to the intersection of the appropriate contactor s life-load curve. Read the estimated contact life along the vertical axis. C- (to 690V) Contact Life (Millions of Operations) 0 Non- or slightly inductive loads, resistance furnaces Ue = 230...690 VC C7-9 C7-2 C7-6 C7-23 C7-30 C7-40 C7-37 C7-43 C7-60 C7-72 C7-85 C7-97 / C7-90 C7-90 C7 Contactors 0. 0 Rated operating current Ie C- [] 00 000 Instructions on How to read Life Curves can be found on page 8 C-2 (to 460V) Contact Life (Millions of Operations) 0 C7-2 C7-9 Slip-ring motors: starting, switching off C7-6 C7-23 C7-30 C7-37 C7-43 Ue = 230 400 460 VC C7-60 C7-72 C7-85 C7-97 ➊ 0. 0 Rated operating current Ie C-2 [] 00 Switching of squirrel-cage motors while starting Ue = 230 400 460 VC C-3 (to 460V) 0 C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-60 C7-72 C7-85 C7-97 NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 60947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. Contact Life (Millions of Operations) 0. 0 00 Rated operating current Ie C-3 [] ➊ 575V applications use 90% of curve value. 77

Technical Information C7 Contactors Life Load Curves C7 Contactors Life-Load Curves Locate the Rated Operational Current (l e ) along the bottom of the chart and follow the graph lines up to the intersection of the appropriate contactor s life-load curve. Read the estimated contact life along the vertical axis. C-3 (to 575V) 0 Switching of squirrel-cage motors while starting Ue = 500 575 VC C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-60 C7-72 C7-85 C7-97 Contact Life (Millions of Operations) 0. 0 Rated operating current Ie C-3 [] 00 Switching of squirrel-cage motors while starting Ue = 690 VC C-3 (to 690V) 0 C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-60 C7-72 C7-85 C7-97 Contact Life (Millions of Operations) 0. 0 Rated operational current Ie C-3 [] 00 NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 60947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 78

Technical Information C7 Contactors Life Load Curves Life-Load Curves Locate the Rated Operational Current (l e ) along the bottom of the chart and follow the graph lines up to the intersection of the appropriate contactor s life-load curve. Read the estimated contact life along the vertical axis. C-4 (to 460V) Contact Life (Millions of Operations) 0 C7-23 C7-6 C7-2 Squirrel-cage motors: starting, plugging, inching C7-30 C7-37 C7-43 C7-9 C7-60 C7-72 C7-85 C7-97 Ue = 230 460 VC C7 Contactors 0..0 0 00 Rated operating current Ie C-4 [] Squirrel-cage motors: starting, plugging, inching UE = 230 690 VC C-4 (to 690V) 0 C7-23 C7-30 C7-37 C7-43 C7-60 C7-72 C7-85 C7-97 C7-6 C7-2 Contact Life (Millions of Operations) C7-9 0. 0 Rated operating current Ie C-4 [] 00 NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 60947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 79

Technical Information C7 Contactors Life Load Curves C7 Contactors Contact Life for Mixed Utilization Categories C-3 and C-4 In many applications, the utilization category cannot be defined as either purely C-3 or C-4. In those applications, the electrical life of the contactor can be estimated with the following equation: L mixed = L ac3 / [+P ac4 x (L ac3 /L ac4 -)], where: C-3 (90%), C-4 (0%) 0 Squirrel-cage motors: starting, switching off motors during running C7-9 C7-2 C7-6 C7-23 C7-30 C7-37 C7-43 C7-60 C7-72 C7-85 C7-97 Ue = 230 400 460 VC ➊ L mixed L ac3 pproximate contact life in operations for a mixed C-3/C-4 utilization category application. pproximate contact life in operations for a pure C-3 utilization category (from the C-3 life-load curve). Contact Life (Millions of Operations) L ac4 pproximate contact life in operations for a pure C-4 utilization category (from the C-4 life-load curve). P ac4 Percentage of C-4 operations 0. 0 00 Rated operating current Ie C-3 / C-4 [] C-3 (75%), C-4 (25%) Squirrel-cage motors: starting, switching off motors during running Ue = 230 400 460 VC ➊ 0 C7-2 C7-6 C7-23 C7-30 C7-9 C7-37 C7-43 C7-60 C7-72 C7-85 C7-97 Contact Life (Millions of Operations) 0. 0.0 0 Rated operating current Ie C-3 / C-4 [] 00 ➊ 575V applications use 85% of curve value. 80

Technical Information C7 Contactors Life Load Curves Contact Life for Special pplications 00 Heavy duty Starting and Regular Short-time Operation C7-9/2/6 C7-23 C7-30/37 C7-43 C7-60/72/85 C7-97 C7 Contactors Max. Starting / Loading time [s] 0 0 00 000 0000 Starting current / Short time current [] Short-time withstand current Icw at 60º 0000 000 max. current [] C7-43 C7-23 C7-9/2/6 00 C7-97 C7-60/72/85 C7-30/37 Short time duty Continuous duty 0 0 00 000 0000 Time of current flow [s] 8

C7 Contactors Operating Rates The estimated contact life shown in the life-load curves is based on the standard operating rates shown in Table B below. For applications requiring a higher operating frequency, the maximum operating power (Pn in kw or HP) for a given contactor must be reduced to maintain the same contact life. To find a contactor s maximum operating power, for an operating rate greater than shown in Table B, follow these guidelines:. Identify the appropriate curve for the contactor and utilization category from Table B. 2. Locate the appropriate Maximum Operating Rate curve on the following pages. 3. Locate the intersection of the curve with the application s operating rate (ops/hr.) found on the vertical axis. Technical Information C7 Contactors Operating Rates 4. Read the percent of maximum operating power (Pn) of the contactor from the horizontal axis. 5. Multiply the % maximum power by the standard power rating. Example: The contactor selected for an C-4 utilization category application is a C7-6 (0HP at 460V), however, the application requires an operating rate of 200 ops/hr., compared to the standard operating rate of 20 ops/hr. as shown in Table B.. Locate the C-4 Maximum Operating Rate curve on the following pages. 2. Locate the intersection of 200 ops/hr on the C7-6 curve. The data shows that the maximum operating power of the C7-6 contactor in this application is 60%. 3. Therefore, the maximum horsepower that can be switched by the C7-6 contactor in this application is 6 HP (0.60 x 0HP). Table B Standard Operating Rates by Contactor and Utilization Category Contactor C- Max. ops/hr. C-2 Max. ops/hr. C-3 Max. ops/hr. Operating Parameters and Start Time C-4 Max. ops/hr. C-4 @ I e for 200K ops. Max. ops/hr. 40% Duty Cycle 250ms ➊ 250ms 250ms C7-9 000 500 700 200 400 C7-2 000 500 700 50 300 C7-6 000 500 700 20 240 C7-23 000 400 600 80 60 C7-30 400 400 600 80 60 C7-37 400 400 600 70 40 C7-43 300 400 600 70 40 C7-55 300 400 600 70 40 C7-60 600 300 500 70 40 C7-72 600 300 500 60 20 C7-85 600 200 500 50 40 C7-97 250 200 500 50 40 ➊ Duty Cycle or Load Factor Defined as the on time for a given operating cycle per hour including the start time. 40% Duty Cycle is calculated in the following manner: Contactor switches six (6) times per minute (tpm), 250ms start time; 40% duty cycle. To determine the on time and off time: Operations per hour = 360; [60 min x 6 tpm = 360] One operating cycle = 0 sec; [60 min 6 tpm = 0 sec] On time at 40% duty cycle = 4 sec; [0 sec x 0.4 (40%) = 4 sec] 4 sec on time includes the start time of 250ms Off time at 40% duty cycle = 6 sec; [0 sec 4 sec = 6 sec] 82

Technical Information C7 Contactors Operating Rates Operating Rate Curves C- 3000 Non- or slightly inductive loads, resistance furnaces Ue = 230 690 VC C7 Contactors 2500 2000 Max. Operating Rate (Ops/hr) 500 000 C7-9/2/6/23 500 0 C7-60/72/85 C7-30/C7-37 C7-40/43 C7-90/C7-97 0 0 20 30 40 50 60 70 80 90 00 P/Pn [%] C-2 Slip-ring motors: starting, switching off Ue = 230 460 VC 0000 Max. Operating Rate (Ops/hr) 000 C7-9/2/6 C7-23/30/37/43 C7-60/72 C7-85/97 00 0 0 20 30 40 50 60 70 80 90 00 P/Pn [%] 83

Technical Information C7 Contactors Operating Rates Operating Rate Curves C7 Contactors C-3 0000 Squirrel-cage motors: starting, switching off motors during running 250ms Start-up, 40% Duty Cycle Ue = 230...460VC Max. Operating Rate (Ops/hr) 000 C7-9/2/6 C7-23/30/37/43 C7-60/72/85/97 00 0 0 20 30 40 50 60 70 80 90 00 P/Pn [%] C-4 Squirrel-cage motors: starting, plugging, inching 250ms Start-up Ue=230...460VC 000 Max. Operating Rate (Ops/hr) 00 C7-9 C7-2 C7-6 C7-23/30 C7-37/43/60 C7-72 C7-85/97 0 0 0 20 30 40 50 60 70 80 90 00 P/Pn [%] 84

Dimensions C7 C Contactors Series C7, CU7, CNX, CN7 and CL7 (Contactors, Reversing Contactors & Special Use Contactors) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. C7 Contactors C Contactors Catalog Number a b c c c2 ød d d2 C7-9...C7-23; CN7-2, CN7-6, CNX-205...208; C(V)L7-20 C7-30...C7-37; CNX-209; CN7-37 C7-40-M... CL7-30-M40 C7-43 C7-55, CN7-43, CNX-22 C7-60...C7-97, CN7-85 CNX-28 C7-90-M... CL7-60-M40 45 (-25/32) 45 (-25/32) 59 (2-2/64) 54 (2-/8) 72 (2-53/64) 95 (3-3/4) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) 22 (4-5/64) 22 (4-5/64) 80.5 (3-/64) 97.5 (4) 00.5 (4-7/64) 00.5 (4-7/64) 7 (4-49/64) 7 (4-49/64) 75.5 (3-3/32) 92.6 (3-49/64) 95.5 (3-49/64) 95.5 (3-49/64).5 (4-35/64).5 (4-35/64) 6 (/4) 6.5 (7/64) 6.5 (7/64) 6.5 (7/64) 8.5 (2/64) 8.5 (2/64) 2-4.5 (2-3/6) 2-4.5 (2-3/6) 2-4.5 (2-3/6) 2-4.5 (2-3/6) 4-5.4 (4-7/32) 4-5.4 (4-7/32) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 00 (3-5/6) 00 (3-5/6) 35 (-25/64) 35 (-25/64) 45 (-25/32) 45 (-25/32) 55 (2-/64) 55 (2-/64) Reversing Contactors, Capacitor Contactors & ccessories (+...) Contactors with... Dim. [mm] Dim. [inches] auxiliary contact block-front mounting 2-, or 4-pole c/c + 39 c/c +-37/64 auxiliary contact block-side mounting -, or 2-pole a + 9 a + 23/64 pneumatic timing module c/c + 58 c/c + 2-23/64 electronic timing module on coil terminal side b + 24 b + 5/6 reversing contactor w-mech.interlock on side of contactor a+9+a a+ 23/64+a mechanical latch c/c + 6 c/c +2-3/64 interface module on coil terminal side b + 9 b + 23/64 surge suppressor on coil terminal side b + 3 b + /8 Mounting Position Labeling with... label sheet marking tag sheet with clear cover marking tag adapter for V7 Terminals +0 +0 +5.5 +0 +0 +7/32 C contactors 85

C7 Contactors Series C7 with Electronic DC Coil Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Dimensions C7 DC Contactors Catalog Number Coil Code a b b c c c2 Ød d d2 C7-9E C7-23E, CN7-2E CN7-6E C7-30E C7-37E, CN7-37E C7-40E C7-43E 55E, CN7-43E 2E 24E 36E 220E 2E 24E 36E 220E 2E 24E 36E 220E 2E 24E 36E 220E 45 8 ~ 80.5 75.5 6 2-4.5 60 35 (-25/32) (3-3/6) ~ (3-/64) (2-3/32) (5/64) (2-3/6) (2-23/64) (-3/8) 45 8 24 80.5 75.5 6 2-4.5 60 35 (-25/32) (3-3/6) (5/6) (3-/64) (2-3/32) (5/64) (2-3/6) (2-23/64) (-3/8) 45 8 ~ 97.5 92.5 6.5 2-4.5 60 35 (-25/32) (3-3/6) ~ (4) (3-4/64) (/4) (2-3/6) (2-23/64) (-3/8) 45 8 24 97.5 92.5 6.5 2-4.5 60 35 (-25/32) (3-3/6) (5/6) (4) (3-4/64) (/4) (2-3/6) (2-23/64) (-3/8) 59 8 ~ 00.5 95.5 6.5 2-4.5 60 45 (2-2/64) (3-3/6) ~ (3-6/64) (3-49/64) (/4) (2-3/6) (2-23/64) (-25/32) 59 8 24 00.5 95.5 6.5 2-4.5 60 45 (2-2/64) (3-3/6) (5/6) (3-6/64) (3-49/64) (/4) (2-3/6) (2-23/64) (-25/32) 54 8 ~ 00.5 95.5 6.5 2-4.5 60 45 (2-/8) (3-3/6) ~ (3-6/64) (3-49/64) (/4) (2-3/6) (2-23/64) (-25/32) 54 8 24 00.5 95.5 6.5 2-4.5 60 45 (2-/8) (3-3/6) (5/6) (3-6/64) (3-49/64) (/4) (2-3/6) (2-23/64) (-25/32) Reversing Contactors, Capacitor Contactors & ccessories (+...) Contactors with... Dim. [mm] Dim. [inches] auxiliary contact block-front mounting 2-, or 4-pole c/c + 39 c/c +-37/64 auxiliary contact block- left side mounting -, or 2 pole a + 9 a + 23/64 pneumatic timing module c/c + 58 c/c + 2-23/64 electronic timing module on coil terminal side b + 24 b + 5/6 mechanical latch c/c + 6 c/c +6 interface module on coil terminal side b + 9 c/c + 2-3/64 Labeling with... label sheet marking tag sheet with clear cover marking tag adapter for V7 Terminals +0 +0 +5.5 +0 +0 +7/32 Mounting Position Electronic DC contactors 86

Dimensions C7 DC Contactors Series C7 with Two Winding DC Coils Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. C7 Contactors Catalog Number a b c c c2 ød d d2 Two Winding DC Contactors C7-60D...C7-97D CN7-85D C7-90D 72 (2-53/64) 95 (3-3/4) 22 (4-5/64) 22 (4-5/64) 7 (4-49/64) 7 (4-49/64).5 (4-35/64).5 (4-35/64) 8.5 (2/64) 8.5 (2/64) 4-5.4 (4-7/32) 4-5.4 (4-7/32) 00 (3-5/6) 00 (3-5/6) 55 (2-/64) 55 (2-/64) Reversing Contactors, Capacitor Contactors & ccessories (+...) Contactors with... Dim. [mm] Dim. [inches] auxiliary contact block-front mounting 2-, or 4-pole c/c + 39 c/c +-37/64 auxiliary contact block- left side mounting -, or 2 pole a + 9 a + 23/64 pneumatic timing module c/c + 58 c/c + 2-23/64 electronic timing module on coil terminal side b + 24 b + 5/6 mechanical latch c/c + 6 c/c +6 interface module on coil terminal side b + 9 c/c + 2-3/64 Labeling with... label sheet marking tag sheet with clear cover marking tag adapter for V7 Terminals +0 +0 +5.5 +0 +0 +7/32 Mounting Position Two Winding DC contactors 87

Dimensions C7 Contactors C7 Contactors C7 Contactors with Terminal Lugs Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. C7-P-KN23 / KL23 C7-P-K37 C7-P-K43 C7-P-K85 Catalog Number C7-P-KN23 / KL23 C7-P-K37 C7-P-K43 C7-P-K85 With Contactor C7-9...6 C7-23 C7-30 37 C7-43 55 C7-60...97 C Operated Contactor DC Operated Contactor h h2 h3 h4 h h2 h3 h4 6.6 (2-27/64) 6.6 (2-27/64) 67.6 (2-2/32) 69.0 (2-23/32) 79.7 (3-/8) 78.6 (3-3/32) 78.6 (3-3/32) 84.6 (3-2/64) 85.0 (3-/32) 04.7 (4-/8) ~ ~ ~ ~ 7.5 (2-3/6) 74.5 (2-5/6) 86.7 (3-3/64) 88.5 (3-3/64) 90.5 (3-9/6).7 (4-3/8) 87.2 (3-7/6) 05.2 (4-9/64).2 (4-3/8) 2.6 (4-7/6) 79.7 (3-/8) 04.2 (4-3/32) 22.2 (4-3/6) 28.2 (5-3/64) 28.6 (5-/6) 04.7 (4-/8) ~ ~ ~ ~ 5. (4-7/32) 8. (4-2/32) 86.7 (3-3/64) 32. (5-3/64) 34. (5-9/32).7 (4-3/8) 88

Dimensions C7 Contactors C7 Contactors with Paralleling Links Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. C7 Contactors C7-P-B23 C7-P-B37 Catalog Number C7-P-B23 C7-P-K37 With Contactor C7-9...6 C7-23 C7-30 37 C Operated Contactor DC Operated Contactor h h2 h3 h4 h h2 h3 h4 65. (2-9/6) 65. (2-9/6) 69.0 (2-23/32) 90. (3-9/6) 90. (3-9/6) 94.0 (3-45/64) ~ ~ ~ ~ 74.5 (2-5/6) 99.5 (3-29/32) 90.7 (/4) 08.7 (4-9/32) 2.6 (4-7/6) 04.2 (2-3/6) 33.7 (5-7/64) 37.6 (5-3/32) ~ ~ ~ ~ 8. (4-2/32) 43. (5-5/8) 89

Series C9 Contactors Sprecher + Schuh s C9 contactor line combines the simple function of our popular C7 series with the rugged performance demanded in this wide horsepower range. C9 contactors offer a smaller footprint than traditional contactors in this size class. large safety distance in front of the contactor is unnecessary. C9 contactors are also designed so that operation is impossible if the arc chambers are removed. Conversely, once the contactor is energized, the arc chambers cannot be removed. C9 Contactors The modern contactor for demanding applications up to 900HP (@460V) - up to 50HP (@ 575V) broad selection for middle horsepower applications The C9 range consists of sixteen contactors in six frame sizes covering motors from 75 to 900HP at 460V and from 00 to 50HP at 575V. This line is ideally suited for demanding applications such as steel mills, rock quarries, mines or for any middle horsepower application where a sturdy, durable contactor is needed. Electronic coils offer many advantages Behind the attractive outward appearance of the C9 contactor are advanced engineering solutions that offer convenience and savings. The entire line is equipped with an electronically controlled coil that reduces pick-up currents by 80% on average. Holding current is also reduced. Rugged and reliable C9 contactors conform to UL508, IEC 60947 and can be operated at rated voltages up to 600V (UL) and 000V (IEC). High thermal and switching capacities guarantee reliable operation and long life. rc quenching extends contact life ll C9 contactors are designed with sophisticated arc quenching techniques that extinguish damaging breaking arcs quickly. This is accomplished by guiding the arc away from the contacts and into arc chambers, which are built-in to every C9 cover. Safety first Other advantages of the C9 electronic coil include: Direct connection to a PLC. This is a standard feature in larger amp units and optional below 400. Overvoltage protection and suppression circuits are standard, eliminating interference from the coil Smooth, even operation over the entire voltage range minimizes the possibility of contact bounce No safeguards are necessary to bridge brief supply interruptions Precisely defined pick-up and drop-out voltages, eliminate the possibility of chattering Universal Electronic coils operate over a much broader C/DC voltage range, providing flexibility in applications and lower costs due to reduced inventory. Four coils cover six contactor frame sizes from 24-500V C and 24-500V DC. C9 arc chambers are completely enclosed (without arc exhaust vents), offering the best protection against hot arcing gases. 90mm 05mm 40mm 86mm 20mm 438mm (3.54 ) (4.3 ) (5.5 ) (7.32 ) (8.27 ) (7.24 ) 90 6 90 265 400 580 860 46 205 305 460 750 060 370 260 2050 2650

Non-Reversing, Three Pole Contactors With C/DC Coil, Series C9 (Open type only) ➊➌ I e [] Ratings for Switching C Motors (C2 / C3 ) uxiliary Open Type kw (50 Hz) UL/CS HP (60 Hz) Contacts per C-3 C- 3 Ø Contactor 220-380- (400V) (690V) 240V 400V 45V 440V 500V 690V 000V 200V 230V 460V 575V NO NC Catalog Number Price 6 60 37 55 55 75 75 55 ~ 30 40 75 00 6-- -L ➋ 760 6-EI-- -L ➋ 80 46 225 45 75 75 90 90 90 75 40 50 00 25 46-- -L ➋ 93 46-EI-- -L ➋ 963 90 275 55 90 90 0 90 32 0 50 60 25 50 90-- 530 90-EI-- 580 205 350 55 0 0 32 0 60 32 60 75 50 200 205-- 740 205-EI-- 790 265 400 75 32 32 60 60 200 32 75 00 200 250 265-- 890 265-EI-- 940 305 500 90 60 60 60 200 250 32 00 25 250 300 305-- 220 305-EI-- 270 370 600 0 200 200 200 220 35 32 25 50 300 350 370-- 2830 370-EI-- 2880 400 600 0 200 220 220 250 35 220 25 50 350 400 400-EI-- 450 460 700 32 250 250 250 35 355 280 50 200 400 500 460-EI-- 5250 480 800 60 35 355 355 400 500 355 200 250 500 600 580-EI-- 750 750 050 220 400 425 450 530 600 400 250 300 600 700 750-EI-- 000 860 350 250 475 500 560 560 800 555 ~ 400 800 000 860-EI-- 7000 060 650 35 560 630 70 70 000 600 ~ 450 900 50 060-EI-- 9300 ~ 260 ~ ~ ~ ~ ~ ~ ~ ~ ~ 260-EI-- 5900 ~ 2050 ~ ~ ~ ~ ~ ~ ~ ~ ~ 2050-EI-- 22600 ~ 2650 ~ ~ ~ ~ ~ ~ ~ ~ ~ 2650-EI-- 25200 Contactors - C/DC Coil Three Pole - Series C9 6 contactor 400-EI contactor C9 Contactors _-EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC ~5VDC (6m) to 33VDC (20m) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment 0V 24V OFF ON Supply voltage 2 X5 Contactor ON OFF_N 2 COMMON 3 860-EI contactor PLC Interface EI connection Coil Codes Electronic Coils V 24-60V 48-30V 00-250V 250-500V 6 370 C/DC 24W 48W 20W 480W 6-EI 370-EI ~ ~ 20W 480W 400-EI 750-EI 24W ➍ 48W 20W 480W C/DC with 860-EI 060-EI ~ ~ 20W ~ PLC Input 260-EI 24W ➍ 48W 20W 480W 2050-EI 2650-EI ~ ~ 20W ~ Note: 90 2650 open-type contactors include terminal bolts. If lugs are required, see page 94 for ordering information. Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ -EI designates contactor coil with PLC input. ➋ 6(-EI) 46(-EI) include terminal lugs. To order with terminal bolts remove the letter -L at the end of the catalog number. For example 6(-EI)- --L becomes 6(-EI)- -. ➌ For UL/CS Elevator duty rating, consult Technical Information on page 03. ➍ Coil is rated 24V 60V DC only. 9

C9 Contactors Reversing, Three Pole Contactors With C/DC Coil, Series C9 (Open type only) ➊➋ I e [] Ratings for Switching C Motors (C2 / C3 ) kw (50 Hz) UL/CS HP (60 Hz) uxiliary Contacts per Contactor Contactors, C/DC Coil Reversing Open Type C-3 C- 220-380- 3 Ø ➌➍ (400V) (690V) 240V 400V 45V 440V 500V 690V 000V 200V 230V 460V 575V NO NC Catalog Number Price 6 60 37 55 55 75 75 55 ~ 30 40 75 00 CU9-6-22- -L ➏ 940 CU9-6-EI-22- -L ➏ 2040 46 225 45 75 75 90 90 90 75 40 50 00 25 CU9-46-22- -L ➏ 250 CU9-46-EI-22- -L ➏ 2250 90 275 55 90 90 0 90 32 0 50 60 25 50 CU9-90-22-3500 CU9-90-EI-22-3600 205 350 55 0 0 32 0 60 32 60 75 50 200 CU9-205-22-3920 CU9-205-EI-22-4020 265 400 75 32 32 60 60 200 32 75 00 200 250 CU9-265-22-4380 CU9-265-EI-22-4480 305 500 90 60 60 60 200 250 32 00 25 250 300 CU9-305-22-4840 CU9-305-EI-22-4940 370 600 0 200 200 200 220 35 32 25 50 300 350 CU9-370-22-6260 CU9-370-EI-22-6360 400 600 0 200 220 220 250 35 220 25 50 350 400 CU9-400-EI-22-990 460 700 32 250 250 250 35 355 280 50 200 400 500 CU9-460-EI-22-400 480 800 60 35 355 355 400 500 355 200 250 500 600 CU9-580-EI-22-600 750 050 220 400 425 450 530 600 400 250 300 600 700 CU9-750-EI-22-2300 Larger sizes are possible. Contact your Sprecher + Schuh representative. Three Pole - Series CU9 CU9-90 Reversing Contactor Includes: Mechanical and electrical Interlock Reversing power wiring (using Power Wiring Kit Cat.# PW ) ➌ Mounting plate (when required) Control wiring available; see footnote ➍ _-EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC ~5VDC (6m) to 33VDC (20m) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment 24V 0V Coil Codes Electronic Coils V 24-60V 48-30V 00-250V 250-500V 6 370 C/DC 24W 48W 20W 480W 6-EI 370-EI ~ ~ 20W 480W 400-EI 750-EI 24W ➎ 48W 20W 480W C/DC with 860-EI 060-EI ~ ~ 20W ~ PLC Input 260-EI 24W ➎ 48W 20W 480W 2050-EI 2650-EI ~ ~ 20W ~ OFF ON Supply voltage 2 X5 Contactor ON OFF_N 2 COMMON 3 PLC Interface EI connection Note: 90 2650 open-type contactors include terminal bolts. If lugs are required, see page 94 for ordering information. ➌ For -LW Option Deduct the following from List Price 6 90 75 205 2650 360 ➍ For -CW Option dd the following to List Price ll CU9 20 Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ -EI designates contactor coil with PLC input. ➋ For UL/CS Elevator duty rating, consult Technical Information on page 03. ➌ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example: CU9-6-22- becomes CU9-6-22- -LW. Control wiring is not included. ➍ For control wiring, add suffix -CW to catalog number. For example: CU9-6-22- becomes CU9-6-22- -CW. ➎ Coil is rated 24V 60V DC only. ➏ CU9-6(-EI) 46(-EI) include terminal lugs. To order with terminal bolts remove the letter -L at the end of the catalog number. For example CU9-6(-EI)-22- -L becomes CU9-6(-EI)-22-. 92

NO 28NO 7 NC 26NC 5 uxiliary Contact Blocks uxiliary Contact Blocks Description NO NC uxiliary Contact Block for Side Mounting 2-Pole Two-way numbering for right or left mounting Easy mounting without tools Mirror contact performance to main contactor poles Low power switching down to 24V 50m Low Power uxiliary Contact Block for Side Mounting -Pole Two-way numbering for right or left mounting Easy mounting without tools Mirror contact performance to main contactor poles Electronic compatible, 3V m 0 0 NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the C9 contactor. One auxiliary contact block ( NO + NC) is mounted at the factory (inside left position). Contact rrangement NO 3 NO 44 NO 4 NC 2 NC 32 NC 22 NC 3 NO 43 NO 53 NO 84 NO 54 NC 6 NC 72 NC 62 NC 7 NO 83 NO 8 NO 27 NC 6 NC 25 ccessories - Field Installable C9 Contactors For use with... Catalog Number Price 6 370 Inside left or right S- 9.50 400 2650 Inside left or right S3-9.50 6 370 Outside left or right S2-9.50 400 2650 Outside left or right S4-9.50 6 370 Inside left or right S-B0 ➊ 46 400 2650 Inside left or right S3-B0 ➊ 46 6 370 Inside left or right S-B0 ➊ 46 400 2650 Inside left or right S3-B0 ➊ 46 C9 Contactors Inside Left position (S) Inside Left position (S) Inside Left position (S3) Inside Right position (S3) Outside Left position (S2) Outside Left position (S2) Outside Left position (S4) Outside Right position (S4) 6 370 400 2650 Mechanical Interlocks ccessory Description For use with... Catalog Number Price Mechanical only, without auxiliary contacts Interlocking of two same size contactors Mechanical only, without auxiliary contacts Interlocking of two different size contactors 6 370 M-00 74 400 750, 260 ➋ 860 060, 2050 2650 ➌ 6 46 to 90 205 90 205 to 265 370 M2-00 98 M3-00 629 M4-00 74 M5-00 74 Rod for vertical mounting reversing contactors 400 750 VR750 25 Horizontal mechanical interlock M_-00 Vertical mechanical interlock VR750 ➊ Contact blocks cannot be mounted on the outside of S-B* or S3-B*. ➋ Mounting plate ordered separately. ➌ Mounting plate included. 93

C9 Contactors Terminal Lugs and ccessories Lug or ccessory Connection Wire Sizes For use with Terminal Lug Kit - Standard for 6-_-L 46-_-L Includes 2 sets, one for Line side and one for Load Side ccessories - Field Installable C9 Contactors Catalog Number 2 x 6 WG 3/0 WG 6(-EI) 46(-EI) CL46 26 Price Order Pkg for 2 kits Order Pkg for 3 lugs Terminal Lugs Includes set of 3 lugs for use on either Line or Load Side. Order qty of 2 for both. Terminal Enlargements Enlargement pieces designed to increase the width of the contactor terminal pads in order to allow larger connections to be mounted Terminal Extensions Extension pieces designed to extend the main terminals of contactors for combined mounting of contactors and connection sets 6 WG 300 MCM 90(-EI) 205(-EI) TL205 78 4 WG 400 MCM 265(-EI) 370(-EI) TL370 6 2 x 4 WG 500 MCM 265(-EI) 370(-EI) TL370B 70 3 x 2/0 WG 500 MCM 400-EI 460-EI TL580 300 2 x 2/0 WG 500 MCM 580-EI 750-EI, 260-EI TL750 434 4 x 4/0 WG 500 MCM 860-EI TL860 578 4 x /0 WG 750 MCM 060-EI TL060 82 6 x /0 WG 750 MCM 060-EI TL060B 098 6(-EI) 46(-EI) TE46 94 90(-EI) 205(-EI) TE205 9 265(-EI) 370(-EI) TE370 84 400-EI 460-EI TE460 236 580-EI 750-EI TE750 35 260-EI TE260 48 6(-EI) 46(-EI) TX46 67 90(-EI) 205(-EI) TX205 82 265(-EI) 370(-EI) TX370 49 400-EI 460-EI TX460 6 580-EI 750-EI TX750 220 Terminal Shrouds ccessory Description For use with... Catalog Number Price For contactors with Terminal Lugs Package contains 2 shrouds, one for Line and one for Load side For contactors with Compression Lugs Package contains 2 shrouds, one for Line and one for Load side For IP20 protection between contactor and overload relay on a non-reversing starter For IP20 protection between contactor and overload relay on a reversing starter 90(-EI) 205(-EI) TS205C 57 265(-EI) 370(-EI) TS370C 57 400-EI 460-EI TS460C 85 580-EI 750-EI, 260-EI TS750C 0 6(-EI) 46(-EI) TS46L 59 90(-EI) 205(-EI) TS205L 59 265(-EI) 370(-EI) TS370L 59 400-EI 460-EI TS460L 87 580-EI 750-EI TS750L 03 CT9-6(-EI) 46(-EI) TC46 42 CT9-90(-EI) 205(-EI) TC205 54 CUT9-6(-EI) 46(-EI) TCR46 74 CUT9-90(-EI) 205(-EI) TCR205 84 See page 09 for terminal wire ranges. 94

ccessories - Field Installable C9 Contactors Power Wiring Connection Kits Connection Kits pplication For use with Catalog Number Price 6(-EI) 46(-EI) PW46 89 90(-EI) 205(-EI) PW205 ➊ 249 Reversing Power Wiring Kits 265(-EI) 370(-EI) PW370 ➊ 397 400-EI 460-EI PW460 ➋ 549 580-EI 750-EI PW750 ➋ 725 Delta Contactor Wye Contactor 6(-EI) 46(-EI) 6(-EI) 46(-EI) PWD46 235 PW46 90(-EI) 205(-EI) 6(-EI) 46(-EI) PWD90 346 90(-EI) 205(-EI) 90(-EI) 205(-EI) PWD205 364 Wye-Delta Power Wiring Kits 265(-EI) 370(-EI) 90(-EI) 205(-EI) PWD265 423 265(-EI) 370(-EI) 265(-EI) 370(-EI) PWD370 505 400-EI 460-EI 400-EI 460-EI PWD460 658 PWD460 580-EI 750-EI 400-EI 460-EI PWD580 756 580-EI 750-EI 580-EI 750-EI PWD750 880 6(-EI) 46(-EI) PWY46 46 90(-EI) 205(-EI) PWY205 97 Shorting Bar 265(-EI) 370(-EI) PWY370 08 400-EI 460-EI PWY460 09 580-EI 750-EI PWY750 55 C9 Contactors Mounting Plates (For 6 750 Contactors) pplication Description For use with Catalog Number Price Non-Reversing Starters 6(-EI) 46(-EI) MS46 43 90(-EI) 205(-EI) MS205 52 6(-EI) 46(-EI) MR46 5 90(-EI) 205(-EI) MR205 63 Reversing Contactors 265(-EI) 370(-EI) MR370 79 400-EI 460-EI MR460 93 580-EI 750-EI MR750 6 Reversing Starters 6(-EI) 46(-EI) MRS46 88 90(-EI) 205(-EI) MRS205 06 ➊ Power wiring kit includes one set of terminal extensions TX_. If terminal lugs TL_ are to be used on line and load side of reversing contactor, a second set of TX_ terminal extensions is required. ➋ If terminal lugs TL_ are to be used on the line and load side of reversing contactor, two sets of terminal extensions TX_ are also required (none included). 95

C9 Contactors Renewal Coils - C/DC, Electronic Coil Electronic Coil (typical) For use with... Voltage Coil Code Catalog Number Replacement Coil without EI Interface includes coil and cover Replacement Coil with EI Interface includes coil, cover and face plate 6 6-EI 46 46-EI 90 205 90-EI 205-EI 265 370 265-EI 305-EI 370-EI 400-EI, 460-EI 580 750-EI, 260-EI 860-EI 060-EI, 2050-EI 24-60V C/DC 24W TG93 48-30V C/DC 48W TG94 00-250V C/DC 20W TG95 250-500V C/DC 480W TG96 00-250V C/DC w/ PLC Interface 20W TGE93 250-500V C/DC w/ PLC Interface 480W TGE94 24-60V C/DC 24W TG90 48-30V C/DC 48W TG902 00-250V C/DC 20W TG903 250-500V C/DC 480W TG904 00-250V C/DC w/ PLC Interface 20W TGE903 250-500V C/DC w/ PLC Interface 480W TGE904 24-60V C/DC 24W TG905 48-30V C/DC 48W TG906 00-250V C/DC 20W TG907 250-500V C/DC 480W TG908 00-250V C/DC w/ PLC Interface 20W TGE95 250-500V C/DC w/ PLC Interface 480W TGE96 00-250V C/DC w/ PLC Interface 20W TGE907 250-500V C/DC w/ PLC Interface 480W TGE908 24-60V C/DC 24W TG909 48-30V C/DC 48W TG90 00-250V C/DC 20W TG9 250-500V C/DC 480W TG92 00-250V C/DC w/ PLC Interface 20W TGE97 250-500V C/DC w/ PLC Interface 480W TGE98 00-250V C/DC w/ PLC Interface 20W TGE99 250-500V C/DC w/ PLC Interface 480W TGE920 00-250V C/DC w/ PLC Interface 20W TGE9 250-500V C/DC w/ PLC Interface 480W TGE92 24-60V DC 24W THE90 48-30V C/DC 48W THE902 00-250V C/DC 20W THE903 250-500V C/DC 480W THE904 24-60V DC 24W TJE90 48-30V C/DC 48W TJE902 00-250V C/DC 20W TJE903 250-500V C/DC 480W TJE904 00-250V C/DC 20W 2650-EI 00-250V C/DC 20W TKE903 ➊ TKE904 ➋ TLE903 ➊ TLE904 ➋ Renewal Parts C9 Contactors Price/ Set 97 ➊ One set of two (2) coils. ➋ Printed circuit board. 96 Discount Schedule B6

Renewal Contact Kits and rc Chutes Description For use with... Catalog Number Contact Kits rc Chutes Price/ Set 6(-EI) 6 292 46(-EI) 46 468 90(-EI) 90 582 205(-EI) 205 754 265(-EI) 265 945 305(-EI) 305 30 370(-EI) 370 350 400-EI 400 620 460-EI 460 2000 580-EI 580 290 750-EI 750 3930 860-EI 860 4840 060-EI 060 5590 260-EI 260 450 2050-EI 2050 590 2650-EI 2650 ➊ 6380 400-EI 460-EI C460 30 580-EI 750-EI, 260-EI 860-EI 060-EI, 2050-EI C750 448 C060 650 2650-EI C2650 938 Renewal Parts C9 Contactors C9 Contactors Replacement Terminal Hardware Description For use with... Catalog Number Price/ Set 6 46(-EI) HF46 39.80 90 205(-EI) HF205 52.80 265 370(-EI) HF370 67.0 Standard Screws 400 460-EI HF460 80.80 and Washers 580, 750, 060-EI HF750 22.00 2050-EI HF2050 4.00 2650-EI HF2650 69.00 ➊ Movable contacts only. Discount Schedule B6 97

C9 Contactors Contactors Cross Reference, Series C & C6 to Series C9 (Open Type Only) ➊ Obsolete Contactor Cross Reference C or C6 to C9 Contactors Ratings for Switching C Motors (C2 / C3 / C4) Series C Series C6 Series C9 I e [] kw (50 Hz) UL/CS HP (60 Hz) Obsolete Obsolete Equivalent 400V / Ø 3 Ø Catalog Catalog Catalog C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V Number Number Number 5 250 37 64/66 80 0 25 40 40 75 00 C6-5 6 60 30 55 75 55 30 40 75 00 6 0 25 40 40 75 00 C-60 40 250 45 78/82 80 5 30 40 50 00 25 C6-40 46 225 45 75 90 90 40 50 00 25 46 5 30 50 50 00 25 C-00 80 250 57 0/05 98 35 ~ 40 50 60 50 50 C6-80 90 275 55 90 90 32 50 60 25 50 90 ~ ~ 60 60 50 50 C-50 205 350 55 0 0 60 60 75 50 200 205 20 350 67 8/22 47 205 ~ 50 60 75 50 200 C6-20 ~ ~ 75 00 200 250 C-250 250 350 80 40/45 77 250 ~ ~ 75 00 200 250 C6-250 265 400 75 32 60 200 75 00 200 250 265 300 450 97 70/76 23 293 ~ ~ 00 25 250 300 C6-300 305 500 90 60 200 250 00 25 250 300 305 ~ ~ 50 50 350 400 C-480 400 600 0 200/220 250 35 25 50 350 400 400 420 500 35 238/250 298 424 ~ ~ 50 75 350 400 C6-420 460 700 32 250 35 355 50 200 400 500 460 580 800 60 35/355 400 500 200 250 500 600 580 630 800 200 355 450 500 ~ ~ 200 250 500 600 C6-630 750 050 220 400/425 520 600 250 300 600 700 750 860 000 250 500 560 ~ ~ ~ 250 300 600 700 C6-860 860 350 257 475/500 560 800 ~ 400 800 000 860 C-0 Contactor C6-40-EI contactor ➊ vailable auxiliary contacts may vary. See selection pages for more information. 98

General Data Rated Isolation Voltage U i IEC UL; CS 6 2650 Rated Voltage U imp (kv) 8 Rated Voltage U e - Main Contacts [V] [V] 000V 600V C 50/60Hz [V] 5,200,230,240,400,45,460,500,575,690,000 DC [V] 24, 48, 0, 220, 440 Operating Frequency for C Loads [Hz] 50/60Hz Electromagnetic compatibility IEC 60947- - Environment Insulation Class of the Coil Class F per IEC 60947-4- Rated Coil Frequency mbient Temperature C 50/60 Hz, DC Storage [ºC] -40 +70 Operation at rated voltage [ºC] -40 +70 Max. ltitude of Installation Site [m] 3000 Climatic Withstand 6 370: 400 2650: IEC 60068-2-30 Test Db & IEC 60068-2-2 test Bd & IEC 60068-2- test b (report 34369) IEC 60068-2-2 test Ba & Bb & IEC 60068-2- test a & b, IEC 60068-2-30 Resistance to Shock IEC 60068-2-27 Resistance to Vibration IEC 60068-2-6 Protection Class Contactor main contacts Contactor coil terminals uxiliary contacts Functional Safety Data (6 750) ➊ IP00 P2X (in connected state) P2X (in connected state) 6 370: B0:.0E+06 operations at 50% max. C-3 load Failure ration: 75% failure to open, 25% failure to close B0: 5.0E+06 operations mechanical only Failure ration: 50% failure to open, 50% failure to close 400 750: B0:.0E+05 operations at 50% max. C-3 load Failure ration: 75% failure to open, 25% failure to close B0: 3.0E+06 operations mechanical only Failure ration: 50% failure to open, 50% failure to close Technical Information C9 Contactors C9 Contactors Standards pprovals Certifications IEC/EN 60947-, Low-voltage switch gear and control gear; IEC/EN 60947-4-, Low-voltage switch gear and control gear, Contactors and motor starters; IEC/EN 60947-5-, Low-voltage switch gear and control gear, Control circuit devices and switching elements; UL 60947-4-, Industrial Control Equipment (US); CS C22.2 No. 4, Industrial Control Equipment (Canada) Mechanically Linked Contacts: IEC 60947-5-, nnex L Mirror Contacts: IEC 60947-4-, nnex F culus, File No. E4850/E9620 (contactors, reversing contactors) CCC, EC, RIN, BS, RCM CE, SUV 6 750 with all S* side mounted NC auxiliary contacts 99

C9 Contactors Electrical Data, Main Circuits Coil Type: Electronic 6 46 90 205 265 305 C- ctive Power Load (50/60Hz) mbient temperature 690V [] 60 225 275 350 400 500 600 600 700 800 050 350 650 260 2050 2650 40ºC 000V [] ~ 225 250 275 350 375 400 600 700 800 000 350 650 260 2050 2650 230V [kw] 64 90 0 36 59 99 239 239 279 39 48 538 657 502 87 056 240V [kw] 67 94 4 45 66 208 249 249 29 333 436 56 686 524 852 02 400V [kw] 56 9 242 277 346 46 46 485 554 727 935 43 873 420 836 45V [kw] 5 62 98 252 288 359 43 43 503 575 755 970 86 906 474 905 500V [kw] 39 95 238 303 346 433 520 520 606 693 909 69 429 09 775 2295 690V [kw] 9 269 329 48 478 598 77 77 837 956 255 63 972 506 2450 367 000V [kw] ~ 390 433 476 606 650 693 039 22 386 732 2338 2858 282 355 4590 mbient temperature 690V [] 45 200 250 300 350 400 500 500 600 700 875 50 450 040 750 2350 60ºC 000V [] ~ 200 225 250 300 325 350 500 600 700 875 50 450 040 750 2350 230V [kw] 58 80 00 20 39 59 99 99 239 279 349 458 578 44 697 936 240V [kw] 60 83 04 25 45 66 208 208 249 29 364 478 603 432 727 977 400V [kw] 00 39 73 208 242 277 346 346 46 485 606 797 005 72 22 628 45V [kw] 04 44 80 26 252 288 359 359 43 503 629 827 042 748 258 689 500V [kw] 26 73 27 260 303 346 433 433 520 606 758 996 259 90 56 2035 690V [kw] 73 239 299 359 48 478 598 598 77 837 046 374 733 243 209 2809 000V [kw] ~ 346 390 433 520 563 606 866 039 22 56 992 25 80 303 4070 mbient temperature 690V [] 30 75 200 240 290 325 400 400 480 580 720 000 270 875 500 220 70ºC 000V [] ~ 75 85 200 240 260 290 400 480 580 720 000 270 875 500 220 230V [kw] 52 70 80 96 6 29 59 59 9 23 287 398 506 349 598 845 240V [kw] 54 73 83 00 2 35 66 66 200 24 299 46 528 364 624 88 400V [kw] 90 2 39 66 20 225 277 277 333 402 499 693 880 606 039 469 45V [kw] 93 26 44 73 208 234 288 288 345 47 58 79 93 629 078 524 500V [kw] 3 52 73 208 25 28 346 346 46 502 624 866 00 758 299 836 690V [kw] 55 209 239 287 347 388 478 478 574 693 860 95 58 046 793 2534 000V [kw] ~ 303 320 346 46 450 502 693 83 005 247 732 2200 56 2598 3672 With conductor sizes [mm 2 ] 70 95 50 240➊ 240 300➋ 2x85➋ 2x85 2x240 2x240 800➌ 000➍ 500➍ 000➌ 2000➍ 3000➍ 370 400 460 580 750 Technical Information C9 Contactors 860 060 260 2050 2650 ➊ For currents above 275, use terminal extensions. ➋ For currents above 450, use terminal extensions. ➌ Maximum connection bar width 50mm. ➍ Maximum connection bar width 00mm. 00

Electrical Data, Main Circuits Coil Type: Electronic 6 46 90 205 265 305 370 400 460 580 750 Technical Information 860 060 C9 Contactors Switching of 3-phase Motors; (50Hz) mbient temperature 220-240V [] 6 46 90 205 265 305 370 400 460 580 750 860 060 ~ ~ ~ 60ºC, C-2, C-3 380-400V [] 6 46 90 205 265 305 370 400 460 580 750 860 060 ~ ~ ~ 45V [] 6 46 90 205 265 305 370 400 460 580 750 860 060 ~ ~ ~ 440V [] 6 46 90 205 265 305 370 400 460 580 750 860 060 ~ ~ ~ 500V [] 0 30 35 65 250 290 35 400 460 580 750 800 970 ~ ~ ~ 690V [] 65 93 35 65 250 290 35 350 400 500 650 800 970 ~ ~ ~ 000V [] ~ 60 85 00 00 00 00 55 200 250 300 375 400 ~ ~ ~ 220-240V [kw] 37 45 55 55 75 90 0 0 32 60 220 250 35 ~ ~ ~ 380-400V [kw] 55 75 90 0 32 60 200 200 250 35 400 457 560 ~ ~ ~ 45V [kw] 55 75 90 0 32 60 200 220 250 355 425 500 630 ~ ~ ~ 440V [kw] 75 90 0 32 60 60 200 220 250 355 50 560 70 ~ ~ ~ 500V [kw] 75 90 90 0 200 200 220 250 35 400 530 560 70 ~ ~ ~ 690V [kw] 55 90 32 60 200 250 35 35 355 500 600 800 000 ~ ~ ~ 000V [kw] ~ 75 0 32 32 32 32 220 280 355 400 555 600 ~ ~ ~ 260 2050 2650 C9 Contactors Load Carrying Capacity per culus General Purpose Current (enclosed) Rated Power (enclosed) 3-Phase with 3 poles in series [] 60 200 250 300 350 400 520 550 650 750 900 350 650 20 200 2700 200V [] 92 20 50 77 22 285 359 359 44 552 692 954 030 ~ ~ ~ 230V [] 04 30 54 92 248 32 360 360 480 604 722 954 030 ~ ~ ~ 460V [] 96 24 56 80 240 302 36 44 477 590 722 954 030 ~ ~ ~ 575V [] 99 25 44 92 242 289 336 382 472 578 672 944 050 ~ ~ ~ 200V [HP] 30 40 50 60 75 00 25 25 50 200 250 ~ ~ ~ ~ ~ 230V [HP] 40 50 60 75 00 25 50 50 200 250 300 400 50 ~ ~ ~ 460V [HP] 75 00 25 50 200 250 300 350 400 500 600 800 900 ~ ~ ~ 575V [HP] 00 25 50 200 250 300 350 400 500 600 700 000 50 ~ ~ ~ 260V DC [] 60 200 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 300V DC [] ~ ~ 230 250 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 340V DC [] ~ ~ ~ ~ 350 400 520 ~ ~ ~ ~ ~ ~ ~ ~ ~ 600V DC [] ~ ~ ~ ~ ~ ~ ~ 500 650 750 900 050 350 20 900 ~ 0

C9 Contactors Electrical Data, Main Circuits Coil Type: Electronic 6 46 90 205 265 305 370 400 460 580 750 Technical Information 860 060 C9 Contactors Switching of 3-phase Motors, (50Hz) mbient temperature 230V [] 84 03 28 56 95 230 280 307 377 ~ ~ ~ ~ ~ ~ ~ 60ºC, C-4 240V [] 84 03 25 56 95 230 280 307 377 ~ ~ ~ ~ ~ ~ ~ 400V [] 84 03 28 56 95 230 280 307 377 ~ ~ ~ ~ ~ ~ ~ 45V [] 84 03 28 56 95 230 280 307 377 ~ ~ ~ ~ ~ ~ ~ 500V [] 84 03 28 56 95 230 280 307 377 ~ ~ ~ ~ ~ ~ ~ 690V [] 66 80 93 04 53 62 88 33 350 ~ ~ ~ ~ ~ ~ ~ 000V [] ~ 48 72 85 90 95 00 4 55 ~ ~ ~ ~ ~ ~ ~ 230V [kw] 22 30 37 45 55 75 90 90 0 ~ ~ ~ ~ ~ ~ ~ 240V [kw] 22 30 37 45 55 75 90 90 0 ~ ~ ~ ~ ~ ~ ~ 400V [kw] 45 55 55 75 0 32 60 60 200 ~ ~ ~ ~ ~ ~ ~ 45V [kw] 45 55 75 90 0 32 60 60 200 ~ ~ ~ ~ ~ ~ ~ 500V [kw] 58 7 90 0 37 63 200 28 267 ~ ~ ~ ~ ~ ~ ~ 690V [kw] 63 77 90 00 50 57 85 335 346 ~ ~ ~ ~ ~ ~ ~ 000V [kw] ~ 67 00 9 26 33 40 200 220 ~ ~ ~ ~ ~ ~ ~ C-4 at approximately 200,000 operations 230V [] 40 40 49 55 77 89 00 8 35 ~ ~ ~ ~ ~ ~ ~ 240V [] 40 40 49 55 77 89 00 8 35 ~ ~ ~ ~ ~ ~ ~ 400/45V [] 40 40 49 55 77 89 00 8 35 ~ ~ ~ ~ ~ ~ ~ 500V [] 28 33 36 45 53 60 69 80 87 ~ ~ ~ ~ ~ ~ ~ 690V [] 28 33 36 45 53 60 69 80 87 ~ ~ ~ ~ ~ ~ ~ 000V [] ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 230V [kw] 5 22 22 30 37 37 ~ ~ ~ ~ ~ ~ ~ 240V [kw] 5 5 22 22 30 37 45 ~ ~ ~ ~ ~ ~ ~ 400V [kw] 8.5 8.5 22 30 37 45 55 63 75 ~ ~ ~ ~ ~ ~ ~ 45V [kw] 22 22 22 30 45 45 55 55 75 ~ ~ ~ ~ ~ ~ ~ 500V [kw] 8.5 22 22 30 37 37 45 55 55 ~ ~ ~ ~ ~ ~ ~ 690V [kw] 22 30 30 37 50 55 63 75 80 ~ ~ ~ ~ ~ ~ ~ 000V [kw] ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Max. switching frequency [ops/hr] 50 50 50 50 50 50 50 60 60 ~ ~ ~ ~ ~ ~ ~ 260 2050 2650 Wye-Delta (60Hz) 200V [HP] 60 75 75 00 50 50 200 250 300 350 450 600 600 ~ ~ ~ 230V [HP] 60 75 00 25 50 200 250 250 350 450 500 700 700 ~ ~ ~ 460V [HP] 50 50 200 250 350 450 500 600 700 800 000 250 500 ~ ~ ~ 575V [HP] 50 200 250 300 450 500 600 700 800 000 250 750 750 ~ ~ ~ 02

Technical Information C9 Contactors Electrical Data, Main Circuits Coil Type: culus Elevator Duty Electronic 6 46 90 205 265 305 370 200V [] 54 54 77 99 25 49 56 ~ ~ ~ ~ ~ ~ ~ ~ ~ 230V [] 54 54 77 99 25 49 56 ~ ~ ~ ~ ~ ~ ~ ~ ~ 460V [] 54 54 77 99 25 49 56 ~ ~ ~ ~ ~ ~ ~ ~ ~ 575V [] 54 54 77 99 25 49 56 ~ ~ ~ ~ ~ ~ ~ ~ ~ 200V [HP] 5 5 20 30 40 40 50 ~ ~ ~ ~ ~ ~ ~ ~ ~ 230V [HP] 20 20 25 30 40 50 60 ~ ~ ~ ~ ~ ~ ~ ~ ~ 460V [HP] 40 40 60 75 00 00 25 ~ ~ ~ ~ ~ ~ ~ ~ ~ 575V [HP] 50 50 75 00 25 50 50 ~ ~ ~ ~ ~ ~ ~ ~ ~ 400 460 580 750 860 060 260 2050 2650 C9 Contactors culus HVC pplications Definite purpose rating (3-Phase) FL [] 6 60 200 250 300 350 520 ~ ~ ~ ~ ~ ~ ~ ~ ~ 230V [] 700 960 200 500 800 200 320 ~ ~ ~ ~ ~ ~ ~ ~ ~ LR 460V [] 580 800 000 250 500 750 2600 ~ ~ ~ ~ ~ ~ ~ ~ ~ 575V [] 470 640 800 000 200 400 2080 ~ ~ ~ ~ ~ ~ ~ ~ ~ C resistance heating 600V [] 60 200 250 300 400 450 520 ~ ~ ~ ~ ~ ~ ~ ~ ~ Star-Delta Starting (50Hz) 230V [] 200 252 329 355 458 528 640 692 796 004 299 489 835 ~ ~ ~ 240V [] 200 252 329 355 458 528 640 692 796 004 299 489 835 ~ ~ ~ 400V [] 200 252 329 355 458 528 640 692 796 004 299 489 835 ~ ~ ~ 45V [] 200 252 329 355 458 528 640 692 796 004 299 489 835 ~ ~ ~ 500V [] 90 225 233 285 433 502 545 692 796 004 299 385 680 ~ ~ ~ 690V [] 2 6 233 285 433 502 545 692 796 004 299 385 680 ~ ~ ~ 000V [] ~ 03 47 73 73 73 73 268 346 433 59 ~ ~ ~ ~ ~ 230V [kw] 55 75 90 0 32 60 200 200 250 35 400 500 560 ~ ~ ~ ➊ 240V [kw] 55 75 0 0 32 60 200 200 250 35 400 500 630 ~ ~ ~ 400V [kw] 0 32 60 200 250 250 355 400 400 560 70 800 000 ~ ~ ~ 45V [kw] 0 32 60 200 250 35 355 400 400 560 800 900 00 ~ ~ ~ 500V [kw] 32 60 60 200 35 355 355 500 500 73 800 000 300 ~ ~ ~ 690V [kw] 90 32 200 250 400 500 500 560 70 800 00 400 700 ~ ~ ~ 000V [kw] ~ 32 200 250 250 250 250 355 500 630 70 ~ ~ ~ ~ ~ ➊ Power rating at 50Hz. Preferred values according to IEC 60947-4-. ➎ Data not available at time of printing. 03

C9 Contactors Electrical Data, Main Circuits Coil Type: Electronic 6 Switching of Power Trasnformers, C-6a (50Hz) Inrush Current = n Rated transformer current n = 30 46 90 205 265 305 370 230V [] 70 79 5 43 43 65 200 252 263 286 430 254 362 ~ ~ 240V [] 70 79 5 43 43 65 200 252 263 286 430 254 362 ~ ~ 400V [] 70 79 5 43 43 65 200 252 263 286 430 254 362 ~ ~ 45V [] 70 79 5 43 43 65 200 252 263 286 430 254 362 ~ ~ 500V [] 70 79 5 43 43 65 200 252 263 286 ~ ~ 362 ~ ~ 690V [] 70 79 5 43 43 65 200 252 263 286 ~ ~ 362 ~ ~ 000V [] ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 230V [kw] 28 3 44 46 57 57 66 80 00 05 4 7 209 44 ~ ~ 240V [kw] 29 33 46 48 59 59 69 83 05 09 9 79 28 50 ~ ~ 400V [kw] 48 55 77 80 99 99 4 39 75 82 98 298 363 25 ~ ~ 45V [kw] 50 56 79 82 02 02 7 42 79 87 203 305 372 257 ~ ~ 500V [kw] 6 68 96 00 24 24 43 73 28 228 248 ~ ~ 34 ~ ~ 690V [kw] 84 94 33 37 7 7 97 239 30 34 342 ~ ~ 433 ~ ~ 000V [kw] ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ n = 20 690V [] 05 9 67 73 25 25 248 300 378 395 429 ~ ~ 543 ~ ~ n = 5 690V [] 40 58 222 230 286 286 330 400 504 526 572 ~ ~ 724 ~ ~ 400 460 580 750 Technical Information 860 060 C9 Contactors 260 2050 2650 60 Hz Peak Inrush/peak rated transformer current 660V [] 70 79 5 43 43 65 200 252 263 286 430 524 362 ~ ~ 200V [kv] 24 27 38 40 50 50 57 69 87 9 99 49 82 25 ~ ~ 208V [kv] 25 28 40 4 52 52 59 72 9 95 03 55 89 30 ~ ~ n = 30 240V [kv] 29 33 46 48 59 59 69 83 05 09 9 79 28 50 ~ ~ 480V [kv] 58 66 92 96 9 9 37 66 20 29 238 357 436 30 ~ ~ 600V [kv] 73 82 5 20 49 49 7 208 262 273 297 447 545 376 ~ ~ 660V [kv] 80 90 27 3 63 63 89 229 288 30 327 492 599 44 ~ ~ 660V [] 05 9 67 73 25 25 248 300 378 395 429 645 786 543 ~ ~ 200V [kv] 36 4 58 60 74 74 86 04 3 37 49 223 272 88 ~ ~ 208V [kv] 38 43 60 62 77 77 89 08 36 42 55 232 283 96 ~ ~ n = 20 240V [kv] 44 49 69 72 89 89 03 25 57 64 78 268 327 226 ~ ~ 480V [kv] 87 99 39 44 79 79 206 249 34 328 357 536 653 45 ~ ~ 600V [kv] 09 24 74 80 223 223 258 32 393 40 446 670 87 564 ~ ~ 660V [kv] 20 36 9 98 246 246 284 343 432 452 490 737 899 62 ~ ~ 660V [] 40 58 222 230 286 286 330 400 504 526 572 860 048 724 ~ ~ 200V [kv] 48 55 77 80 99 99 4 39 75 82 98 298 363 25 ~ ~ 208V [kv] 50 57 80 83 03 03 9 44 82 90 206 30 378 26 ~ ~ n = 5 240V [kv] 58 66 92 96 9 9 37 66 20 29 238 357 436 30 ~ ~ 480V [kv] 6 3 85 9 238 238 274 333 49 437 476 75 87 602 ~ ~ 600V [kv] 45 64 23 239 297 297 343 46 524 547 594 894 089 752 ~ ~ 660V [kv] 60 8 254 263 327 327 377 457 576 60 654 983 98 828 ~ ~ 04

Electrical Data, Main Circuits Coil Type: Electronic 6 46 90 205 265 305 370 400 460 580 750 Technical Information 860 060 C9 Contactors Switching of 3-Phase Capacitors, C-6b (50Hz) 230V [kvar] 40 50 60 75 85 00 0 20 40 70 220 250 300 ~ ~ ~ 240V [kvar] 40 50 60 75 85 00 0 20 40 70 220 250 300 ~ ~ ~ 400V [kvar] 75 90 0 30 45 65 200 20 240 285 400 450 500 ~ ~ ~ Single capacitor 45V [kvar] 75 90 0 30 45 65 200 20 240 285 400 450 500 ~ ~ ~ 40ºC 500V [kvar] 83 0 40 60 80 20 240 260 325 350 490 550 600 ~ ~ ~ 690V [kvar] 80 0 35 70 200 240 280 300 325 440 600 650 800 ~ ~ ~ 000V [kvar] ~ 00 40 50 55 60 70 250 300 350 450 ~ ~ ~ ~ ~ 230V [kvar] 40 50 60 75 85 00 0 20 40 70 220 250 300 ~ ~ ~ 240V [kvar] 40 50 60 75 85 00 0 20 40 70 220 250 300 ~ ~ ~ 400V [kvar] 75 90 0 30 45 65 200 20 240 285 400 450 500 ~ ~ ~ Single capacitor 45V [kvar] 75 90 0 30 45 65 200 20 240 285 400 450 500 ~ ~ ~ 55ºC 500V [kvar] 83 0 40 60 80 20 240 260 325 350 490 550 600 ~ ~ ~ 690V [kvar] 80 0 35 70 200 240 280 300 325 440 600 650 800 ~ ~ ~ 000V [kvar] ~ 00 40 50 55 60 70 250 300 350 450 ~ ~ ~ ~ ~ 230V [kvar] 35 42 45 57 70 85 00 05 20 60 90 230 280 ~ ~ ~ 240V [kvar] 35 42 45 57 70 85 00 05 20 60 90 230 280 ~ ~ ~ 400V [kvar] 65 74 83 05 35 55 80 95 225 275 370 430 480 ~ ~ ~ Single capacitor 45V [kvar] 65 74 83 05 35 55 80 95 225 275 370 430 480 ~ ~ ~ 70ºC 500V [kvar] 78 96 02 30 65 96 220 24 300 340 435 530 570 ~ ~ ~ 690V [kvar] 75 0 35 60 200 240 260 300 325 440 600 630 750 ~ ~ ~ 000V [kvar] ~ 95 20 30 40 50 60 220 270 300 400 ~ ~ ~ ~ ~ 200V [kvar] 33 4.569 50 66.683 83 00 25.05 4 37 7 205 ~ 346 ~ ~ ~ 60Hz Single Capacitor 230V [kvar] 38 47.804 57 76.686 95 5 43.8 3 57 96 236 ~ 398 ~ ~ ~ - 40ºC 460V [kvar] 75 00 25 50 200 250 300 274 329 4 494 ~ 832 ~ ~ ~ 600V [kvar] 00 25 50 200 250 300 350 343 40 54 68 ~ 040 ~ ~ ~ 260 2050 2650 C9 Contactors Switching of Lamps Gas discharge lamps C-5a (Open) [] 6 46 90 205 265 305 370 400 460 580 750 877 072 82 332 722 UL Ballast Ratings [] 60 200 250 300 400 450 520 ~ ~ ~ ~ ~ ~ ~ ~ ~ Filament C-5b 230/240V [] 6 46 90 205 265 305 370 400 460 580 750 877 072 82 332 722 05

C9 Contactors Electrical Data, Main Circuits Coil Type: Electronic 6 46 90 205 265 Switching of DC Loads Non-inductive or slightly inductive loads or resistance furnaces DC- at 60ºC 24V [] 60 200 250 350 400 500 520 600 700 800 050 350 650 250 2050 ~ 48/60V [] 60 200 250 350 400 500 520 600 700 800 050 350 650 250 2050 ~ -Pole 0V [] ~ ~ ~ ~ 400 500 520 600 700 800 050 250 350 650 2050 ~ 220V [] ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 440V [] ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 24V [] 60 200 250 350 400 500 520 600 700 800 050 350 650 250 2050 ~ 48/60V [] 60 200 250 350 400 500 520 600 700 800 050 350 650 250 2050 ~ 2 Poles in series 0V [] 60 200 250 350 400 500 520 600 700 800 050 350 650 250 2050 ~ 220V [] ~ ~ ~ ~ 400 500 520 600 700 800 050 ~ ~ ~ ~ ~ 440V [] ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 24V [] 60 200 250 350 400 500 520 600 700 800 050 350 650 250 2050 ~ 48/60V [] 60 200 250 350 400 500 520 600 700 800 050 350 650 250 2050 ~ 3-Poles in series 0V [] 60 200 250 350 400 500 520 600 700 800 050 350 650 250 2050 ~ 220V [] ~60 200 250 350 400 500 520 600 700 800 050 250 350 650 2050 ~ 440V [] ~ ~ ~ ~ ~ ~ ~ 600 700 800 050 250 350 650 2050 ~ Shunt-wound motors Starting, reverse current breaking, reversing, stepping DC-3, 60ºC 24V [] 45 60 250 275 350 400 450 600 700 800 050 ~ ~ ~ ~ ~ 48/60V [] 45 60 250 275 350 400 450 600 700 800 050 ~ ~ ~ ~ ~ 3-Poles in series 0V [] 45 60 250 275 350 400 450 600 700 800 050 ~ ~ ~ ~ ~ 220V [] 45 60 250 275 350 400 450 600 700 800 050 ~ ~ ~ ~ ~ 440V [] ~ ~ ~ ~ ~ ~ ~ 600 700 800 050 ~ ~ ~ ~ ~ Series-wound motors Starting, reverse current breaking, reversing, stepping DC-5, 60ºC 24V [] 45 60 250 275 350 400 450 600 700 800 050 ~ ~ ~ ~ ~ 48/60V [] 45 60 250 275 350 400 450 600 700 800 050 ~ ~ ~ ~ ~ 3-Poles in series 0V [] 45 60 250 275 350 400 450 600 700 800 050 ~ ~ ~ ~ ~ 220V [] 45 60 250 275 350 400 450 600 700 800 050 ~ ~ ~ ~ ~ 440V [] ~ ~ ~ ~ ~ ~ ~ 600 700 800 050 ~ ~ ~ ~ ~ 305 370 400 460 580 750 Technical Information C9 Contactors Short Time Withstand l cw 60 C s [] 300 460 900 2050 2650 3050 3700 4600 4600 7000 7000 0000 2000 8000 2000 2000 0 s [] 928 68 520 640 220 2446 2960 4400 4400 6400 6400 8000 0000 7200 0000 0000 30 s [] 536 674 878 947 224 409 709 300 300 4500 4500 6000 7500 5200 7500 7500 min [] 379 477 62 670 865 996 208 2500 2500 3500 3500 4500 5500 4000 5500 5500 5 min [] 60 225 275 350 400 500 600 840 840 300 300 600 2200 500 2200 2800 Resistance and Power Dissipation Main current circuit resistance [mω] 0.469 0.454 0.98 0.204 0.200 0.200 0.200 0.083 0.086 0.050 0.045 0.044 0.029 0.050 0.030 0.028 Power dissipation per pole at I e C-, 400V [W] 2 23 5 25 32 50 72 30 42 32 50 80 80 80 25 200 Power dissipation per pole at I e C-3, 400V [W] 6 0 7 8 4 9 27 6 2 7 28 50 50 ~ ~ ~ Total power dissipation at: I e C3, 400V; C/DC control 20-250V) [W] 2 33 23.5 26.5 46.5 6.5 85.5 53 68 56 89 7 7 ~ ~ ~ Maximum Switching Frequency C- ops/hr 300 300 300 300 300 300 300 300 300 300 300 60 60 300 60 5 C-3 ops/hr 300 300 300 300 300 300 300 300 300 300 300 60 60 ~ ~ ~ C-2, C-4 ops/hr 50 50 50 50 50 50 50 60 60 60 60 60 60 ~ ~ ~ 860 060 260 2050 2650 Weight C/DC (Electronic) with bar connections with built-in cable clamps kg.5.5 3 3 4.64 4.64 4.64 2 2 5 5 34 35 6 35 45 (lbs) (3.3) (3.3) (6.6) (6.6) (0.2) (0.2) (0.2) (26.4) (26.4) (33) (33) (74.8) (77) (35.2) (77) (99) kg.75.75 (lbs) (3.85) (3.85) ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 06

Technical Information C9 Contactors Short Circuit Ratings 6 46 90 205 265 Shirt Circuit Coordination (Max. Fuse or Circuit Breaker Rating) per IEC 60947-4- DIN Fuses -gg 00 k vailable Fault Current Type 2 (400V) [] 250 250 35 35 400 500 630 630 630 800 800 000 250 ~ ~ ~ DIN Fuses -gg 80 k vailable Fault Current Type 2 (690V) [] 60 200 35 35 400 425 500 500 630 800 800 000 600 ~ ~ ~ MCCB 70 k vailable Fault Current Type 2 (400V) [] 60 60 320 320 400 630 630 630 630 800 000 600 600 ~ ~ ~ 305 370 400 460 580 750 860 060 260 2050 2650 C9 Contactors Shirt Circuit Coordination (Max. Fuse or Circuit Breaker Rating) per UL 60947 and CS 22.2 No. 4 (contactor and fuses or circuit breaker only) UL Class RK5 Fuses 0 k vailable Fault Current Type Combination (600V) [] 250 250 400 400 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ UL Class J and CS HRCI-J Fuses 82 k vailable Fault Current Type Combination (600V) [] ~ ~ ~ ~ ~ ~ ~ 600 600 200 200 ~ ~ ~ ~ ~ UL Class J and CS HRCI-J Fuses 00 k vailable Fault Current Type Combination (600V) [] 250 250 400 400 600 600 800 600 600 ~ ~ ~ ~ ~ ~ ~ Type 2 Combination (600V) [] 200 200 400 400 600 600 600 600 600 ~ ~ ~ ~ ~ ~ ~ UL Class L Fuses 8 k vailable Fault Current Type Combination (600V) [] ~ ~ ~ ~ 800 800 800 ~ ~ ~ ~ ~ ~ ~ ~ ~ UL Class L Fuses 30 k vailable Fault Current Type Combination (600V) [] ~ ~ ~ ~ ~ ~ ~ 000 000 ~ ~ ~ ~ ~ ~ ~ UL Class L Fuses 85 k vailable Fault Current Type Combination (600V) [] ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 600 600 ~ ~ ~ UL Class L Fuses 00 k vailable Fault Current Type Combination (600V) [] ~ ~ ~ ~ ~ ~ ~ 800 800 200 200 ~ ~ 600 ~ ~ Type 2 Combination (600V) [] ~ ~ ~ ~ ~ ~ ~ ~ ~ 200 200 ~ ~ ~ ~ ~ UL Inverse-Time Circuit 42 k vailable Fault Current Type Combination (480V) [] ~ ~ ~ ~ ~ ~ ~ ~ ~ 200 200 ~ ~ ~ ~ ~ UL Inverse-Time Circuit 65 k vailable Fault Current Type Combination (480V) [] 250 250 400 400 800 800 800 800 800 800 800 ~ ~ ~ ~ ~ UL Inverse-Time Circuit 84 k vailable Fault Current Type Combination (480V) [] ~ ~ ~ ~ ~ ~ ~ 600 800 ~ ~ ~ ~ ~ ~ ~ UL Inverse-Time Circuit 89 k vailable Fault Current Type Combination (480V) [] ~ ~ ~ ~ ~ ~ ~ ~ ~ 800 800 ~ ~ ~ ~ ~ UL Inverse-Time Circuit 00 k vailable Fault Current Type Combination (480V) [] 250 250 400 400 800 800 800 ~ ~ ~ ~ ~ ~ ~ ~ ~ UL Inverse-Time Circuit 25 k vailable Fault Current Type 2 Combination (600V) [] 250 250 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ UL Inverse-Time Circuit 35 k vailable Fault Current Type 2 Combination (600V) [] ~ ~ 400 400 800 800 800 600 800 800 800 ~ ~ ~ ~ ~ UL Inverse-Time Circuit 42 k vailable Fault Current Type Combination (600V) [] ~ ~ ~ ~ 800 800 800 600 800 800 800 ~ ~ ~ ~ ~ UL Inverse-Time Circuit 50 k vailable Fault Current Type Combination (600V) [] 250 250 ~ ~ ~ ~ ~ ~ ~ 800 800 ~ ~ ~ ~ ~ UL Inverse-Time Circuit 65 k vailable Fault Current Type Combination (600V) [] ~ ~ 400 400 400 400 400 ~ ~ ~ ~ ~ ~ ~ ~ ~ 07

C9 Contactors Coil Data Coil type: Electronic Operating Limits 50/60 Hz DC control 24 60V C 48 30V C 00 250V C 250 500V C 24 60V DC 48 30V DC 00 250V DC 250 500V DC 6 46 90 205 265 370 400 460 580 750 860 060 Technical Information C9 Contactors 260 2050 2650 pick-up [xus] 0.85. dropout [xus] 0.55 pick-up [xus] 0.80. dropout [xus] 0.55 pick-up [V] 225 65 475 ~ ~ ~ ~ ~ hold-in [V] 5.5 6 8.5 ~ ~ ~ ~ ~ pick-up [V] 70 75 340 25 00 ~ 00 ~ hold-in [V] 4 4 7 2 2 ~ 2 ~ pick-up [V] 30 220 385 955 880 2450 880 2450 hold-in [V] 6 7 7.5 2 2 48 2 48 pick-up [V] 205 85 420 950 985 ~ 985 ~ hold-in [V] 6 6 2 2 2 ~ 2 ~ pick-up [W] 20 205 400 900 785 ~ 785 ~ hold-in [W] 2.5 2.5 3.5 5 5.5 ~ 5.5 ~ pick-up [W] 30 30 360 50 020 ~ 20 ~ hold-in [W] 2.5 2.5 2.5 5 5 ~ 5 ~ pick-up [W] 35 90 40 895 880 2290 880 2290 hold-in [W] 3 2.5 4.5 5 5 20.5 5 20.5 pick-up [W] 205 90 600 885 90 ~ 90 ~ hold-in [W] 4 4 4.7 7.5 7.5 ~ 7.5 ~ Operating Times C or DC With PLC Interface closing delay [ms] 20 55 25 60 30 60 50 20 50 20 50 80 50 20 50 80 opening delay [ms] 40 70 45 80 45 80 33 70 33 70 35 55 33 70 35 55 closing delay [ms] 20 3 25 45 25 45 40 60 40 90 40 65 40 90 40 65 opening delay [ms] 24 34 25 45 25 45 0 30 0 30 0 30 0 30 0 30 08

Mechanical Data Main Terminals Conductor Cross Sections - Main Contacts Terminal Type 6 Ø 6.5 3 46 7 90 3 Ø 8.5 7.5 205 0 265 305 9.5 5 Ø 0.5 4.3 5 370 400 25 22.5 Ø 0.5 Ø 6.5 460 6 580 40 22.5 Ø 6.5 Ø 2.5 750 6 860 Ø 3 Technical Information 80 40 27 060 0 0 30 7 C9 Contactors () conductor [mm 2 ] 0 95 6 50 6 300 ~ ~ ~ ~ ~ ~ Clamp Type CL46 TL205 TL370 ~ ~ ~ ~ ~ ~ Recommended torque [Nm] 8 34 42 ~ ~ ~ ~ ~ ~ (2) conductors [mm 2 ] 0 95 ~ 6 500 70 500 70 500 20 500 70 750 ~ ~ Clamp Type CL46 ~ TL370B TL580 TL750 TL860 TL060 ~ ~ Recommended torque [Nm] 8 ~ 42 3 43 43 57 ~ ~ (3) conductors [mm 2 ] ~ ~ ~ ~ 70 500 20 500 70 750 70 500 ~ Clamp Type ~ ~ ~ ~ TL750 TL860 TL060 TL750 Recommended torque [Nm] ~ ~ ~ ~ 43 43 57 43 ~ (4) conductors [mm 2 ] ~ ~ ~ ~ ~ 20 500 70 750 ~ ~ Clamp Type ~ ~ ~ ~ ~ TL860 TL060 ~ Recommended torque [Nm] ~ ~ ~ ~ ~ 43 57 ~ ~ (6) conductors [mm 2 ] ~ ~ ~ ~ ~ ~ 70 750 ~ ~ Clamp Type ~ ~ ~ ~ ~ ~ TL060B ~ Recommended torque [Nm] ~ ~ ~ ~ ~ ~ 57 ~ ~ L L max. [mm] 22 24 32 47 50 00 50 00 Ø ø min. [mm] 6 8 0 0 2 2 2 2 Recommended torque [Nm] 9 8 28 35 45 45 45 45 Ø 3 260 50 27 25 5.5 8 2050 80 40 40 7 2650 Ø 3 (F2050) 0 (F2650) 25 C9 Contactors Cross Section per culus () conductor [WG] 6 3/0 6 300 MCM 4 400 MCM ~ ~ ~ ~ ~ ~ Clamp Type CL46 TL205 TL370 ~ ~ ~ ~ ~ ~ Recommended torque [lb-in] 80 300 375 ~ ~ ~ ~ ~ ~ (2) conductors [WG] 6 3/0 ~ 4 500 MCM 2/0 500 MCM 2/0 500 MCM 4/0...500 MCM /0...750 MCM 2/0...500 MCM ~ Clamp Type CL46 ~ TL370B TL580 TL750 TL860 TL060 TL750 ~ Recommended torque [lb-in] 80 ~ 375 275 375 375 500 375 ~ (3) conductors [WG] ~ ~ ~ ~ 2/0 500 MCM 4/0...500 MCM /0...750 MCM 2/0...500 MCM ~ Clamp Type ~ ~ ~ ~ TL750 TL860 TL060 TL750 Recommended torque [lb-in] ~ ~ ~ ~ 375 375 500 375 ~ (4) conductors [WG] ~ ~ ~ ~ ~ 4/0...500 MCM /0...750 MCM ~ ~ Clamp Type ~ ~ ~ ~ ~ TL860 TL060 ~ Recommended torque [lb-in] ~ ~ ~ ~ ~ 375 500 ~ ~ (6) conductors [WG] ~ ~ ~ ~ ~ ~ /0...750 MCM ~ ~ Clamp Type ~ ~ ~ ~ ~ ~ TL060B ~ Recommended torque [lb-in] ~ ~ ~ ~ ~ ~ 500 ~ ~ L L max. [in] 0.866 0.945.26.85.97 3.94.97 3.94 Ø ø min. [in] 0.236 0.35 0.394 0.394 0.472 0.472 0.472 0.472 Recommended torque [lb-in] 80 60 248 30 398 398 398 398 Conductor Cross Sections Coil Terminals Terminal Type () conductor [mm 2 ] 0.75 2.5 (2) conductors [mm 2 ] 0.75 2.5 () conductor [mm 2 ] 4 (2) conductors [mm 2 ] 4 Recommended torque [Nm].2 Cross section per culus [WG] 8 4 Recommended torque [lb-in] 8.9 0.6 09

C9 Contactors Electrical Data, uxiliary Contacts For Reversing and Non-Reversing S/2* S3/4* S*-B* Switching of C Loads Rated Insulation voltage U i 690V 690V 250V Rated Operational voltage U e 690V 690V 25V Rated Impulse Withstand voltage U imp 6kV 6kV.5kV C-2 I th at 40ºC [] 6 6 0. C-4 at rated voltage of C-5 at rated voltage of Switching of DC Loads DC-2 L/R < ms resistive loads at DC-2 L/R < 5 ms inductive loads with economy resistor in series at DC-3 switching electromagnetics at at 60ºC [] ~ ~ ~ 24V [] ~ ~ 0. 42/48V [] ~ ~ 0. 20V [] ~ ~ 0. 24V [] 6 6 ~ 42/48V [] 6 6 ~ 20V [] 6 6 ~ 230V [] 4 4 ~ 240V [] 4 4 ~ 400V [] 3 3 ~ 45V [] 3 3 ~ 500V [] 2 2 ~ 690V [] 2 2 ~ 24V DC [] ~ ~ 0. 48V DC [] ~ ~ 0. 0V DC [] ~ ~ 0. 220V DC [] ~ ~ ~ 440V DC [] ~ ~ ~ 24V DC [] ~ ~ ~ 48V DC [] ~ ~ ~ 0V DC [] ~ ~ ~ 220V DC [] ~ ~ ~ 440V DC [] ~ ~ ~ 24V DC [] 3 6 ~ 48V DC [].5 2.8 ~ 0V DC [] 0.55 0.55 ~ 220V DC [] 0.3 0.3 ~ 440V DC [] ~ ~ ~ Technical Information C9 Contactors Fuse gg Short-circuit protection with no welding of contacts per IEC 60947-5-2 [] 0 0 0. [] 0 0 0. Protective Separation per IEC 60947-, nnex N Min. Switching capacity at 24V IEC 60947-5-4 [m] 50 50 ~ Min. Switching capacity at 3V IEC 60947-5-4 [kv] ~ ~ Load Carrying Capacity per culus Rated voltage C [V] 600 600 25 Continuous rating 40ºC [] 0 0 0. Switching capacity C 600 600 ~ Rated voltage DC [V] 250 250 25 Continuous rating 40ºC [] 2.5 2.5 0. Switching capacity DC P 600 Q 300 ~ 660V [kv] 60 8 254 0

Technical Information C9 Contactors - Contact Life Life-Load Curves 3-Pole Contactors Electrical Durability 0 Electrical durability for C- utilization category - U e 690V ➊ Switching non-inductive or slightly inductive loads. The breaking current I c for C- is equal to the rated operational current of the load. 6 46 90 205 265 305 370 400 460 580 750 C9 Contactors 5 Millions of Operations 3 2 0.5 9 7 5 3 9 7 5 3 0.3 0.2 9 7 5 3 3 5 7 9 5 9 3 5 7 9 0. 3 5 7 9 3 5 7 9 3 579 5 9 2 3 5 0 20 30 50 00 200 300 500 000 Breaking current I c [] Instructions on How to read Life Curves can be found on page 8 ➊ 860 and 060 electrical durability at the rated current is 50,000 operating cycles.

Technical Information C9 Contactors - Contact Life C9 Contactors Life-Load Curves 3-Pole Contactors Electrical Durability 0 Electrical durability for C-3 utilization category - U e 440V ➊ Switching cage motors: starting and switching off running motors. The breaking current I c for C-3 is equal to the rated operational current I e (I e = motor full load current). 6 90 205 265 305 370 46 400 460 580 750 5 Millions of Operations 3 2 9 7 5 3 9 7 5 3 0.5 0.3 0.2 3 5 7 9 3 5 7 9 3 5 7 9 5 9 3 5 7 9 3 5 7 9 2 3 5 0 20 30 50 00 200 300 500 000 5 9 3 579 Breaking current I c [] Electrical durability for C-3 utilization category - 440V < U e 6900V ➊ Switching cage motors: starting and switching off running motors. The breaking current I c for C-3 is equal to the rated operational current I e (I e = motor full load current). 0 6 46 90 205 265 305 370 400 460 580 750 5 Millions of Operations 3 2.5 9 7 5 3 9 7 5 3 0.5 0.3 3 5 7 9 5 9 3 5 7 9 0.2 3 5 7 9 3 579 3 5 7 9 3 579 3 5 7 9 2 3 5 0 20 30 50 00 40 200 300 500 000 Breaking current I c [] ➊ 860 and 060 electrical durability at the rated current is 50,000 operating cycles. 2

Technical Information C9 Contactors Operating Rates Life-Load Curves 3-Pole Contactors Electrical Durability 0 Electrical durability for C-2 or C-4 utilization category - U e 440V Switching cage motors: startingreversing, and step-by-step operation. The breaking current I c is equal to 2.5 x I e for C-2 and 6 x I e for C-4, keeping in mind that I e is the motor rated operational current (I e = motor full load current). 6/46 90 205 265 305 370 400 460 580 750 C9 Contactors 5 3 2 9 7 5 3 Millions of Operations 0.5 0.3 0.2 0. 0.05 0.03 9 7 5 3 0.02 0.0 9 7 5 3 3 5 7 9 3 5 7 9 0.005 3 5 7 9 3 5 7 9 3 5 7 9 2 3 5 0 20 30 50 00 200 300 500 000 2000 3000 5000 Breaking current I c [] 3

Technical Information C9 Contactors Operating Rates C9 Contactors Life-Load Curves 3-Pole Contactors Electrical Durability 0 Electrical durability for C-2 or C-4 utilization category - 440V < U e 690V Switching cage motors: startingreversing, and step-by-step operation. The breaking current I c is equal to 2.5 x I e for C-2 and 6 x I e for C-4, keeping in mind that I e is the motor rated operational current (I e = motor full load current). 46 90 205 265 305 370 6 400 460 580 750 5 3 2 9 7 5 3 Millions of Operations 0.5 0.3 0.2 0. 0.05 0.03 9 7 5 3 0.02 0.0 9 7 5 3 3 5 7 9 0.005 3 5 7 9 3 5 7 9 3 5 7 9 2 3 5 0 20 30 50 00 200 300 500 000 2000 3000 5000 Breaking current I c [] 4

Dimensions C9 Contactors 0 (0.39) 90 (3.54) Series 6 46-_-L (Contactors/Reversing Contactors) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 26 (4.96) 30 (.8) M4 (8-32 UNC) C9 Contactors 50 (5.9) D 55.5 (2.8) 9.5 (0.77) 00 (3.94) 30 (.8) Series 6-EI 46-EI-_-L (Contactors/Reversing Contactors with PLC Interface) 0 (0.39) 90 (3.54) 42.5 (5.6) 30 (.8) M4 (8-32 UNC) 50 (5.9) D 55.5 (2.8) 9.5 (0.77) 00 (3.94) 30 (.8) Mounting Position 30 80 80 20 5

Dimensions C9 Contactors C9 Contactors 0 (0.39) 05 (4.3) ø 8.5 (0.33) Series 90 205 (Contactors/Reversing Contactors) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 35.5 (.40) 52 (5.98) 5 (0.20) 35 (.36) M5 (0-24 UNC) 96 (7.72) 83.5 (3.29) 29.5 (.6) 65 (6.50) 35 (.38) Series 90-EI 205-EI (Contactors/Reversing Contactors with PLC Interface) 0 (0.39) 05 (4.3) ø 8.5 (0.33) 35.5 (.40) 5 (0.20) 69.5 (6.67) 35 (.36) M5 (0-24 UNC) 96 (7.72) 83.5 (3.29) 29.5 (.6) 65 (6.50) 35 (.38) 6

Series 265 370 (Contactors/Reversing Contactors) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Dimensions C9 Contactors 0 40 (5.5) 80 (7.09) (0.39) 9.5 35.5 5 43.75 (.72) M5 (0-24 UNC) ø 0.5 (0.77) (.40) (0.20) (0.4) 225 (8.86) 87 (7.36) C9 Contactors 94.7 (3.73) 33.4 (.3) 43.75 (.72) Series 265-EI 370-EI (Contactors/Reversing Contactors with PLC Interface) 0 (0.39) 40 (5.5) 9.5 (0.77) ø 0.5 (0.4) 35.5 (.40) 95.5 (7.70) 5 (0.20) 43.75 (.72) M5 (0-24 UNC) 225 (8.86) 94.7 (3.73) 33.4 (.3) 87 (7.36) 43.75 (.72) 7

Dimensions C9 Contactors C9 Contactors Series 400-EI 460-EI (Contactors/Reversing Contactors with PLC Interface) 86 (7.32) 25(0.98) 22.5 (0.89) ø 6.5 (0.26) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. ø 0.5 (0.4) 48.5 (.9) 6 (0.24) 26 (8.5) 63 (2.48) 268 (0.55) 278 (0.94) 248 (9.76).5 (0.45) M5 (0-24 UNC) 63 (2.48) Series 580-EI, 750-EI (Contactors/Reversing Contactors with PLC Interface) 40 (.57) 20 (8.27) 22.5 (0.89) ø 6.5 (0.26) ø 2.5 (0.49) 48.5 (.9) 6 (0.24) 242 (9.53) 72 (2.83) 273 (0.75) 283 (.4) 249 (9.8).5 (0.45) M6 (/4-20 UNC) 72 (2.83) 8

Dimensions C9 Contactors 50 (.97) 27 72 (2.83) Series 260-EI (Contactors with PLC Interface) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. ø 7 (0.28) 242 (9.53) 72 (2.83) 344 (3.54) 33 (2.32) C9 Contactors 263 (0.35) 249 (9.8) 249 (9.8) M6 (/4-20 UNC) ø 7 (0.28) 72 (2.83) 20 (8.27) 72 (2.83) 46.5 (8.3) 8 (0.3) Series 860-EI, 060-EI, 2050-EI, 2650-EI (Contactors with PLC Interface) 40 (.57) 27 (.06) ø 3 (0.5) 40 (.57) Dim 860, 060, 2050 2650 3 (0.5) 860, 060 7 (0.67) 30 (.8) 0 (0.39) 2050, 2650 7 (0.67) 40 (.57) 392 (5.43) 422 (6.6 B 47 (.85) 53 (2.09) C 0 (0.39) 25 (0.98) 36 (5.35) 36 (5.35) B 244 (9.6) C 36 (5.35) 32 (2.3) 32 (2.28) 80 (3.5) 0 (3.98) 36 (5.35) 438 (7.24) ø 9 (0.35) 40 (.57) M8 (5/6-8 UMC) 9

C6 Contactors Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 00 to 700HP (@ 575V) DISCONTINUED This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor line combines the simple function of our popular C7 series with the rugged performance demanded in this middle horsepower range. On average these contactors are 50% smaller than traditional contactors in this size class. broad selection for middle horsepower applications The C6 range consists of nine contactors in three frame sizes covering motors from 75 to 600HP at 460V and from 00 to 700HP at 575V. This line is ideally suited for demanding applications such as steel mills, rock quarries, mines or for any middle horsepower application where a sturdy, durable contactor is needed. Rugged and reliable C6 contactors conform to UL508, IEC 60947 and can be operated at rated voltages up to 600V (UL) and 000V (IEC). High thermal and switching capacities guarantee reliable operation and long life. C6 contactors are listed in CS Certified Elevator Equipment for heavy duty use in elevators, refrigerators and heating installations in Canada. rc quenching extends contact life ll C6 contactors are designed with sophisticated arc quenching techniques that extinguish damaging breaking arcs quickly. This is accomplished by guiding the arc away from the contacts and into arc chambers which are built-in to every C6 cover. Safety first C6 arc chambers are completely enclosed (without arc exhaust vents), offering the best protection against hot arcing gases. large safety distance in front of the contactor is unnecessary. C6 contactors are also designed so that operation is impossible if the arc chambers are removed. Conversely, once the contactor is energized, the arc chambers cannot be removed. When used with terminal covers or HB Touch-Safe Lugs, C6 contactors meet international standards for touch-safe design. 20mm ( 4 3/4 ) 5 20mm ( 4 3/4 ) 40 80 55mm ( 6 3/32 ) 20 250 300 420 25mm ( 8 5/32 ) 630 860 20

Electronic coils offer many advantages Behind the attractive outward appearance of the C6 contactor are advanced engineering solutions that offer convenience and savings. The entire line can be equipped with an electronically controlled coil that reduces pick-up currents by 60% on average. Holding current is also reduced. 200 800 500 200 900 600 300 0 Comparison of pick-up and holding current [V] Conventional Coil pick-up holding Electronic Coil Other advantages of the C6 electronic coil include: Direct connection to a PLC Overvoltage protection and suppression circuits (eliminating interference from the coil) are standard DISCONTINUED C6 EI electronic coils offer many unique advantages over conventional types Smooth, even operation over the entire voltage range minimizes the possibility of contact bounce No safeguards are necessary to bridge brief supply interruptions Precisely defined pick-up and dropout voltages, eliminate the possibility of chattering Electronic coils operate over a much broader voltage range, providing flexibility in applications and lower costs due to reduced inventory Two user-selectable modes C6 contactors with electronic coils operate in either the E mode for normal operation or the EI mode for interfacing directly with a Programmable Logic Controller (PLC) or other low level signal source (3...30.2 VDC). The coil is set in the E mode from the factory, offering all of the functions and advantages of an electronic coil with the exception of electronic interface. n orange jumper located on the bottom of the contactor can be quickly changed if interface from a PLC is desired. detailed technical explanation of C6-EI coils along with connection diagrams can be found in the Technical Section. Jumper set in E mode (factory default) Jumper set in EI mode (user selectable) C6 Contactors The entire C6 line is modularly designed for easy inspection, coil change and contact replacement. Maintenance can be performed from the front so that mounting requires no additional space. Even with the installation of mechanical interlocks and auxiliary contact blocks, the units can be flush mounted side by side, saving panel space. 0 3 4 6 7 9 6 7 9 C6-5-EI Contactor 2 C6-40-EI Contactor 3 Main Terminal Set 4 Lug set 5 Mechanical Interlock 6 ux. Contact Block 7 ux. Contact Block 8 ux. Contact Block 9 ux. Contact Block 0 Terminal Cover Surge Suppressor C6 contactors utilize modular design techniques that speed installation, reduce panel space and facilitate maintenance 5 2 5 2 8 8 2

C6 Contactors Non-Reversing, Three Pole Contactors With C Coil, Series C6 (Open type only) ➊➌ Ratings for Switching C Motors (C2 / C3 ) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per Ø 3 Ø Contactor 400V/ C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price 5 250 37 64/66 80 0 25 40 40 75 00 40 250 45 78/82 80 ➍ 5 30 40 50 00 25 80 250 57 0/05 98 ➍ 35 ➍ DISCONTINUED ~ 40 50 60 50 50 C6-5-- C6-5-EI-- C6-40-- C6-40-EI-- C6-80-- C6-80-EI-- 669 805 00 250 540 750 Contactors - C Coil Three Pole - Series C6 C6-40-EI contactor 20 350 67 8/22 47 205 ~ 50 60 75 50 200 C6-20-EI-- 850 250 350 80 40/45 77 250 ~ ~ 75 00 200 250 C6-250-EI-- 2090 300 450 97 70/76 23 293 ~ ~ 00 25 250 300 C6-300-EI-- 2330 420 540 35 238/250 298 424 ~ ~ 50 75 350 400 C6-420-EI-- 4920 630 800 200 355 450 500 ~ ~ 200 250 500 600 C6-630-EI-- 8770 860 000 250 500 560 ~ ~ ~ 250 300 600 700 C6-860-EI-- 900 C6-420-EI contactor Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 29 for ordering information. Coil Codes ➋ C Coil Code C6-5 /40 /80 Voltage Range 50 Hz 60 Hz 24 ~ 24V 20B 0V 20V 208 ~ 208V 240B 220-230V 240V 277 240V 277V 380 380-400V 440V 480 45V 480V 575 500V 575V C6-5-EI...C6-420-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 ➎ 24V 20 0-30V 220W 208-277V 460W 380-500V C6-630-EI...C6-860-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 20 0-30V ➏ 208W 200-220V 240W 230-250V ➏ 277 277V 480 440-480V C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (3-30 VDC at 5m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ -EI designates contactor with Electronic Interface coil. ➋ Other voltages available, see page 34-35. ➌ For CS Elevator duty rating, consult Technical Information on page 39. ➍ Ratings are higher for contactors with electronic coil: C6-40-EI-- C6-80-EI-- 500V = 98 kw 500V = 26 kw 690V = 35 kw 690V = 76 kw ➎ 24 VC Coil is not available for C6-420-EI. ➏ Coil is rated C/DC. 22

Non-Reversing, Three Pole Contactors With DC Coil, Series C6 (Open type only) ➊➌ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per Ø 3 Ø Contactor 400V/ C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price 5 250 37 64/66 80 0 25 40 40 75 00 40 250 45 78/82 80 ➍ 5 30 40 50 00 25 80 250 57 0/05 98 ➍ 35 ➍ DISCONTINUED ~ 40 50 60 50 50 C6-5-L22- C6-5-EI-- C6-40-L22- C6-40-EI-- C6-80-L22- C6-80-EI-- 20 350 67 8/22 47 205 ~ 50 60 75 50 200 C6-20-EI-- 2290 807 920 380 560 90 290 Contactors - DC Coil Three Pole - Series C6 C6-40-EI contactor with DC coil C6 Contactors 250 350 80 40/45 77 250 ~ ~ 75 00 200 250 C6-250-EI-- 2590 300 450 97 70/76 23 293 ~ ~ 00 25 250 300 C6-300-EI-- 2920 420 540 35 238/250 298 424 ~ ~ 50 75 350 400 C6-420-EI-- 630 630 800 200 355 450 500 ~ ~ 200 250 500 600 C6-630-EI-- 8770 860 000 250 500 560 ~ ~ ~ 250 300 600 700 C6-860-EI-- 900 Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 29 for ordering information. C6-420-EI contactor with DC coil Coil Codes ➋ C6-5 / 40 / 80 DC Voltage Range Coil Code 24D 24V 0D 0V 220D 220V Note: Conventional DC coils have high current pick-up winding and low current seal-in winding wired in parallel. The pick-up winding is taken out of the circuit after the armature pulls in. Price includes two winding coil and an L block including one NC late break auxiliary contact mounted on the right side. See page 49 for functional schematic. C6-5-El...C6-420-EI ➊ DC Coil Code Voltage Range 24D ➎ 24V 20D 0-30V 220D 200-255V C6-630...C6-860-EI ➊ DC Coil Code Voltage Range 20 0-30V ➏ 240W 200-255V ➏ C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (3-30 VDC at 5m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ -EI designates contactor with Electronic Interface coil. ➋ Other voltages available, see page 34-35. ➌ For CS Elevator duty rating, consult Technical Information on page 39. ➍ Ratings are higher for contactors with electronic coil: C6-40-EI-- C6-80-EI-- 500V = 98 kw 500V = 26 kw 690V = 35 kw 690V = 76 kw ➎ 24V DC Coil not available for C6-420-EI. Customers selecting 24V DC Coils should consider the EI functionality of the C6 (see page 48). ➏ Coil is rated C/DC. 23

C6 Contactors Reversing, Three Pole Contactors With C Coil, Series C6 (Open type only) ➏ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per Ø 3 Ø Contactor 400V/ C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price 5 250 37 64/66 80 0 25 40 40 75 00 40 250 45 78/82 80 ➐ 5 30 40 50 00 25 80 250 57 0/05 98 ➐ 35 ➐ DISCONTINUED ~ 40 50 60 50 50 CU6-5-22- CU6-5-EI-22- CU6-40-22- CU6-40-EI-22- CU6-80-22- CU6-80-EI-22- Contactors, C Coil Reversing 8.90 2060 270 3030 3600 4050 Three Pole - Series CU6 20 350 67 8/22 47 205 ~ 50 60 75 50 200 CU6-20-EI-22-4670 250 350 80 40/45 77 250 ~ ~ 75 00 200 250 CU6-250-EI-22-550 300 450 97 70/76 23 293 ~ ~ 00 25 250 300 CU6-300-EI-22-5700 420 540 35 238/250 298 424 ~ ~ 50 75 350 400 CU6-420-EI-22-0800 630 800 200 355 450 500 ~ ~ 200 250 500 600 CU6-630-EI-22-9500 860 000 250 500 560 ~ ~ ~ 250 300 600 700 CU6-860-EI-22-25800 CU6-80 reversing contactor Includes: Mechanical and electrical Interlock ➍ Reversing power wiring (using Power Wiring Kit Cat.# C6- VL[T]) ➊ Mounting plate Control wiring available; see footnote ➋ Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 29 for ordering information. Coil Codes ➋ C Coil Code C6-5 /40 80 Voltage Range 50 Hz 60 Hz 24 ~ 24V 20B 0V 20V 208 ~ 208V 240B 220-230V 240V 277 240V 277V 380 380-400V 440V 480 45V 480V 575 500V 575V ➊ For -LW Option Deduct the following from List Price CU6-5 80 75 CU6-20 860 360 ➋ For -CW Option dd the following to List Price ll CU6 20 Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code C6-5-EI...C6-420-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 ➑ 24V 20 0-30V 220W 208-277V 460W 380-500V C6-630-EI...C6-860-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 20 0-30V ➒ 208W 200-220V 240W 230-250V ➒ 277 277V 480 440-480V See Coil Codes on this page C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (3-30 VDC at 5m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil ➊ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example: CU6-5-22- becomes CU6-5-22- -LW. Control wiring is not included. ➋ For control wiring, add suffix -CW to catalog number. For example: CU6-5-22- becomes CU6-5-22- -CW. ➌ -EI designates contactor with Electronic Interface coil. ➍ One NC auxiliary contact on each contactor is used for electrical interlocking. ➎ Other voltages available, see page 34-35. ➏ For CS Elevator duty rating, consult Technical Information on page 39. ➐ Ratings are higher for contactors with electronic coil: C6-40-EI-- C6-80-EI-- 500V = 98 kw 500V = 26 kw 690V = 35 kw 690V = 76 kw ➑ 24 VC Coil is not available for C6-420-EI. ➒ Coil is rated C/DC. 24

Reversing, Three Pole Contactors With DC Coil, Series C6 (Open type only) ➏ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per Ø 3 Ø Contactor 400V/ Catalog C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V NO NC➍ Number ➊➌➎ 5 250 37 64/66 80 0 25 40 40 75 00 40 250 45 78/82 80 ➐ 5 30 40 50 00 25 80 250 57 0/05 98 ➐ 35 ➐ DISCONTINUED 2 2 ~ 40 50 60 50 50 CU6-5-L42- CU6-5-EI-22- CU6-40-L42- CU6-40-EI-22- CU6-80-L42- CU6-80-EI-22-20 350 67 8/22 47 205 ~ 50 60 75 50 200 CU6-20-EI-22-5570 250 350 80 40/45 77 250 ~ ~ 75 00 200 250 CU6-250-EI-22-670 300 450 97 70/76 23 293 ~ ~ 00 25 250 300 CU6-300-EI-22-6840 Contactors, DC Coil Reversing Price 2200 2420 3230 3640 4360 490 420 540 35 238/250 298 424 ~ ~ 50 75 350 400 CU6-420-EI-22-300 630 800 200 355 450 500 ~ ~ 200 250 500 600 CU6-630-EI-22-9500 860 000 250 500 560 ~ ~ ~ 250 300 600 700 CU6-860-EI-22-25800 Three Pole - Series CU6 CU6-80 reversing contactor with DC coil Includes: DC operating mechanism Mechanical and electrical Interlock ➍ Reversing power wiring (using Power Wiring Kit Cat.# C6- VL[T]) ➊ Mounting plate Control wiring available; see footnote ➋ C6 Contactors Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 29 for ordering information. Coil Codes ➎ C6-5 / 40 / 80 DC Coil Code Voltage Range 24D 24V 0D 0V 220D 220V Note: Conventional DC coils have high current pick-up winding and low current seal-in winding wired in parallel. The pick-up winding is taken out of the circuit after the armature pulls in. Price includes two winding coil and an L block including one NC late break auxiliary contact mounted on the right side. See page 49 for functional Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code C6-5-EI...C6-420-EI ➊➑ DC Coil Code Voltage Range 24D ➏ 24V 20D 0-30V 220D 200-255V C6-630...C6-860-EI ➊➑ DC Coil Code Voltage Range 20 0-30V ➒ 240W 200-255V ➒ schematic. ➊ For -LW Option Deduct the following from List Price CU6-5 80 75 CU6-20 860 360 ➋ For -CW Option dd the following to List Price ll CU6 20 See Coil Codes on this page C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (3-30 VDC at 5m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil ➊ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example: CU6-5-22- becomes CU6-5-22- -LW. Control wiring is not included. ➋ For control wiring, add suffix -CW to catalog number. For example: CU6-5- 22- becomes CU6-5-22- -CW. ➌ -EI designates contactor with Electronic Interface coil. ➍ One NC auxiliary contact on each contactor is used for electrical interlocking. ➎ Other voltages available, see page 34-35. ➏ For CS Elevator duty rating, consult Technical Information on page 39. ➐ Ratings are higher for contactors with electronic coil: C6-40-EI-- C6-80-EI-- 500V = 98 kw 500V = 26 kw 690V = 35 kw 690V = 76 kw ➑ 24V DC Coil not available for C6-420-EI. Customers selecting 24V DC Coils should consider the EI functionality of the C6 (see page 48). ➒ Coil is rated C/DC 25

DISCONTINUED Special Use Contactors - C Coil NEM Labeled Contactors - Series CN7 / CN6 C6 Contactors Non-Reversing, Three Pole NEM Labeled Contactors with C Coil ➊➌ NEM Size Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 5V 230V 200V 230V 460V 575V NO NC Catalog Number 00 /3 -/2 -/2 2 2 0 CN7-2-0-0 2 3 3 5 5 0 CN7-6-0-2 3 7-/2 7-/2 0 0 0 CN7-37-0-2 3 7-/2 0 5 25 25 0 CN7-43-0-3 7-/2 5 25 30 50 50 0 CN7-85-0-4 ~ ~ 40 50 00 00 Price See page 42 CN6-80-- 2628 CN6-80-EI-- 3048 5 ~ ~ 75 00 200 200 CN6-300-EI-- 6529 CN6 NEM labeled contactor (C) pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See pages 34-35 for coils and contacts. Snap-on auxiliary contact blocks available in many configurations. See page 32 (C[N]6). Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 29 for ordering information. CN6 C Coil Codes Conventional Coils ➋ CN6-80 C Coil Voltage Range Code 50 Hz 60 Hz 24 ~ 24V 20B 0V 20V 208 ~ 208V 240B 220-230V 240V 277 240V 277V 380 380V-400V 440V 480 45V 480V 575 500V 575V CN6 C Coil Codes EI Electronic Coils ➋➌ CN6-80-EI...300-EI C Coil Voltage Range Code 50 Hz / 60 Hz 24 24V 20 0-30V 220W 208-277V 460W 380-500V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Refer to page 54 for CN6 dimensions. ➋ Other voltages available, see pages 34-35 for CN6 coils. ➌ -EI designates contactor with Electronic Interface coil. 26 Discount Schedule B8

DISCONTINUED Special Use Contactors - DC Coil NEM Labeled Contactors - Series CN7 / CN6 Non-Reversing, Three Pole NEM Labeled Contactors with DC Coil ➊ NEM Size Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 5V 230V 200V 230V 460V 575V NO NC Catalog Number 00 /3 -/2 -/2 2 2 0 CN7-2E-0- ➎ 0 2 3 3 5 5 0 CN7-6E-0- ➎ 2 3 7-/2 7-/2 0 0 0 CN7-37E-0- ➎ 2 3 7-/2 0 5 25 25 0 CN7-43E-0- ➎ 3 7-/2 5 25 30 50 50 2 CN7-85D-0- Price See page 43 CN6 NEM labeled contactor C6 Contactors 4 ~ ~ 40 50 00 00 CN6-80-L22- ➍ 2953 CN6-80-EI-- ➌➍ 3048 5 ~ ~ 75 00 200 200 CN6-300-EI-- ➌➍ 6529 pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See pages 34-35 for coils and contacts. Snap-on auxiliary contact blocks available in many configurations. See page 32. Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 29 for ordering information. CN6 DC Coil Codes Conventional Coils ➋➍ CN6-80-L22 DC Coil Code Voltage Range 24D 24V CN6 DC Coil Codes EI Electronic Coils ➋➍ CN6-80-EI...300-EI DC Coil Code Voltage Range 24D 24V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Refer to page 54 for CN6 dimensions. ➋ Other voltages available, see pages 34-35 for CN6 coils. ➌ -EI designates contactor with Electronic Interface coil. ➍ Customers with 24VDC applications should strongly consider using the EI functionality of the C6 (see pages 48-49). Discount Schedule B8 27

C6 Contactors Hydraulic Elevator Wye Delta, with C Coils (Two Contactor Type ➊➋➎) Maximum Horsepower Three Phase Industrial pplication ➎ CS Elevator Duty ➏ uxiliary Contacts per Contactor Open Type 200V 230V 460V 575V NO NC ➌ Catalog No. Price 60 60 25 50 C6Y2-5-22- -LW 593 40 50 00 25 C6Y2-5-EI-22- -LW 780 60 75 75 200 C6Y2-40-22- -LW 2483 50 60 25 25 C6Y2-40-EI-22- -LW 2803 75 00 200 250 C6Y2-80-22- -LW 3389 60 75 50 50 C6Y2-80-EI-22- -LW 3404 HP Selection DISCONTINUED Larger sizes are possible. Contact your Sprecher + Schuh representative. C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (3-30 VDC at 5m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Reduced Voltage Contactors Wye Delta - Series C6Y2 C6Y2-5 Wye-Delta contactor Includes: Mechanical and electrical Interlocks ➌ Mounting plate Optional: Power wiring available but not included (see page 30) ➊➐ C6-5 C6-80-VYU C6-5 Coil Codes ➍ C Coil Code C6-5 80 Voltage Range 50 Hz 60 Hz 24 ~ 24V 20B 0V 20V 208 ~ 208V 240B 220-230V 240V 277 240V 277V 380 380-400V 440V 480 45V 480V 575 500V 575V C6-5-EI C6-80-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 24V 20 0-30V 220W 208-277V 440W 380-440V ➊ For -PW Option dd the following to List Price C6Y2-5 80 273 2M C6-80-VLHB S Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ For Contactors with power wiring add suffix -PW to catalog number. For example: C6Y2-5-22- -LW becomes C6Y2-5-22- -PW. Control wiring is not included. ➋ -EI designates contactor with Electronic Interface coil. ➌ One NC auxiliary contact on each contactor is used for electrical interlocking. ➍ Other voltages available, see page 34-35. ➎ HP selection based on UL508 for Industrial pplications. ➏ HP selection based on CS Elevator Duty Ratings. ➐ See typical Wye-Delta Wiring Diagram on page C7. 28

DISCONTINUED ccessories - Field Installable C6 Contactors Main Lugs and Lug ccessories Lug or ccessory Connection Description Catalog Number Price Multiple conductors (flat or round) fit in each terminal on C6-HB Main Terminal Sets (top view) ccommodation for dual connections to each pole ccepts flat or round conductors Touch safe to IP20 according to IEC 60529 Eliminates need for Terminal Shields Main Terminal Sets (catalog #: C6-HB ) are specifically designed for connecting line and load to all three poles on C6 contactors. Each touch safe terminal set contains three built-in terminals capable of carrying two round conductors or multiple flat conductors. Main Terminal Sets add a clean finished appearance to C6 contactors Main Terminal Set, Dual Conductor, Touch Safe (price as complete set, containing 2 blocks, 6 lugs) For C6-5(-EI); 40(-EI); 80(-EI) For C6-20-EI to 420-EI C6-HB2 C6-HB3 25 88 C6 Contactors Screw Type Lugs - Single connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For C6-5(-EI); 40(-EI); 80(-EI) For C6-20-EI to C6-420-EI C6-L80 C6-L420 82 79 Screw Type Lugs - ccommodation for dual connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For C6-630-EI C6-L630 35 Screw Type Lugs - ccommodation for dual connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For C6-860-EI C6-L860 456 (Typical) Control Wire Terminal ➊ 2 x 2.5mm 2 For C6-5(-EI); 40(-EI); 80(-EI) C6-T 5.26 For C6-20-EI to 420-EI C6-T2 4.40 ➊ The IP2X lug rating will no longer apply if used with C6-HB_ main terminal set. See Page 45 for terminal wire ranges. 29

DISCONTINUED ccessories - Field Installable C6 Contactors C6 Contactors Power Wiring Connection Kits Connection Kits pplication Used with contactor... Use with Lug... Catalog Number Price C6-80-VLHB Reversing Line Side Wye-Delta Line Side Connects L-L L2-L2 L3-L3 C6-5(-EI) to 80(-EI) C6-5(-EI) to 80(-EI) C6-20-EI to 420-EI C6-630-EI to 860-EI C6-L80 C6-HB2 C6-HB3 C6-420-HU C6-L420 C6-L630 C6-L860 C6-80-VLHB 4 C6-420-VLHB 274 C6-860-VL 525 C6-5(-EI) to 80(-EI) C6-L80 C6-80-VT 48 C6-80-VT Reversing Load Side Connect T-T3 T2-T2 T3-T C6-5(-EI) to 80(-EI) C6-HB2 C6-80-VTHB 48 C6-20-EI to 420-EI C6-HB3 C6-420-VTHB 276 C6-20-EI to 420-EI C6-420-HU C6-L420 C6-420-VT 263 C6-630-EI to 860-EI C6-L860 C6-860-VT 482 C6-80-VYU Wye-Delta Shorting Bar C6-5(-EI) to 80(-EI) C6-20-EI to 420-EI N/ C6-80-VYU C6-420-VYU 4.90 30.30 C6-630-EI to 860-EI N/ C6-860-VYU 59.70 Wye-Delta (2M to S jumper) Connects 2M contactor C6-20-EI to 420-EI... to S contactor C640(-EI ) to 80(-EI) C6-HB3 C6-420-VYHB 234 C6-420-VT Connects 2M contactor C6-20-EI to 420-EI... to S contactor C6-20-EI to 420-EI C6-420-HU C6-L420 C6-420-VT 263 30

DISCONTINUED ccessories - Field Installable C6 Contactors Lug ccessories and Backpans ccessory Description Main Terminal Cover - ➊ C6 touch protection Line or load (price each) IP20; IEC60529 & DIN 40 050 protection For use with contactor... Catalog Number Price C6-5(-EI) to 80(-EI) C6-20-EI to 420-EI C6-630-EI to 860-EI C6-630-EI to 860-EI C6-630-EI to 860-EI C6-630-EI to 860-EI C6-TC80 C6-TC420 C6-TC860 C6-TCS860 ➋ C6-TCR860 ➌ C6-TCE860 ➍ 44.70 73.50 07 50.20 49 474 C6 Contactors Mounting Plates contactor & O/L relay (cross- The-Line) C6-5(-EI)...80(-EI) C6-20-EI...420-EI C6-630-EI...860-EI C6-MS80 C6-MS420 C6-MS860 6.20 98.60 247.00 2 contactors & 2 O/L relays (Reversing or Multispeed) C6-5(-EI)...80(-EI) C6-20-EI...420-EI C6-630-EI...860-EI C6-MU80 C6-MU420 C6-MU860 98.60 48.00 300.00 3 contactors, 2 O/L relays & relay/ timer (Wye-delta) For C6-5(-EI) to 80(-EI) For C6-20-EI to 420-EI C6-630-EI to 860-EI C6-MY80 C6-MY420 C6-MY860 69 204 355 ➊ Terminal Covers not necessary when using Main Terminal Sets (C6-HB ) which are insulated. ➋ DOL starter/relay terminal covers ➌ Reversing starter/relay terminal cover ➍ Line-side panel relay and reversing terminal cover 3

DISCONTINUED ccessories - Field Installable C6 Contactors C6 Contactors uxiliary Contact Blocks, 2 Pole uxiliary Contact Blocks NO NC Contact rrangement 3 44 4 43 53 84 54 2 32 22 3 6 72 62 Mounting Position Catalog Number Price Inside left or right C6-S- 44.20 Outside left or right C6-S2-44.50 NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the C6 contactor. One auxiliary contact block ( NO + NC) is mounted at the factory. New style C6-5 40 contactors with conventional DC coils have an -L mounted to right side and an - mounted to left side at the factory. 7 83 3 25 LB 44 4 36 26 Inside left or right C6-S-L 5.50 35 43 3 23 2 0 53 44 4 43 34 24 33 63 Inside left or right C6-S-20 44.20 Inside left position (C6-S) Inside right position (C6-S) 2 0 84 54 83 74 64 73 Outside left or right C6-S2-20 44.50 Outside left position (C6-S2) Outside right position (C6-S2) Form C Electronic Compatible 32 3 6 34 64 62 Inside left or right C6-S-B ➊ 73.50 Miscellaneous ccessories ccessory Description For use with... Catalog Number Price Mechanical Interlock- No built-in auxiliaries Interlocks C6 contactors CM6-D00 54.90 CM6-D00 Interlocks C6 to C7-60...97 contactors CM6-C02 65.80 Mechanical / Electrical Interlock - Two built-in N.C. auxiliaries CM6-D02 Interlocks C6 contactors CM6-D02 65.80 ➊ Electronic compatible auxiliary contacts function through the use of an internal micro-switch and have the following ratings: IEC 947 Data: C- 250V 0. C-5/DC-3 min. 3 25V 00m UL 508, CS 22.2 Data: 250VC max. 0. Minimum Switching 7V 5m 32

DISCONTINUED ccessories - Field Installable C6 Contactors Miscellaneous ccessories ccessory Description For use with... Catalog Number Price Surge Suppressor - Limits voltage spikes when switching off coil. ttaches to all C6 contactors. RC Link: 2-48V 50Hz. 24-55V 60Hz 95-0V 50 Hz / 0-27V 60 Hz 90-240V 50Hz / 220-277V 60Hz 380-550V 50Hz / 440-575V 60Hz Varistor Link: 2-55V 50/60Hz 56-36V 50/60Hz 37-277V 50/60Hz 278-575V 50/60Hz Varistor Link: 24-28V C/DC 48-72V DC 43-65V 50/60Hz 208-277 50/60 Hz 380-400V 50/60Hz Conventional C Coils Conventional C Coils Electronic (-EI) Coils ➊ CRC6-48 CRC6-0 CRC6-240 CRC6-550 CRV6-55 CRV6-36 CRV6-277 CRV6-575 CRV6-40 CRV6-55 CRV6-75 CRV6-550 CRV6-460 36.60 23.40 23.40 C6 Contactors Marking Systems Component Description Pkg. Qty. Catalog Number Price Each Label Sheet - sheet with 05 self-adhesive paper labels each, 6 x7mm C7-FMS Marking Tag Sheet - sheet with 60 perforated paper labels each, 6 x 7mm. To be used with transparent cover Transparent Cover - To be used with Marking Tag Sheets C7-FMP 00 ➋ C7-FMC See page 54 Tag Carrier - For marking with marker cards and tags. See page N35 for complete listing of available cards and tabs. 00 ➋ C7-FM2 ➊ EI contactors are supplied with factory installed integrated surge protection (see page 35). ➋ Minimum order quantity is one package of 00. Price each x 00 = total price. 33

C6 Contactors Renewal Coils -.C., Conventional Coil ➊ C Control Voltages Conventional Coil C Coil Codes DISCONTINUED For use with contactor... C6-95, C6-0 C6-5, C6-40 C(N)6-80 Optional RC Module ➋ Optional Varistor Module ➋ 50 Hz 60 Hz 50/60 Hz Catalog No. Catalog No. Catalog No. 24V ~ ~ 24 C6-TG407 CRC6-48 CRV6-55 ~ 24V ~ 24 C6-TG03 CRC6-48 CRV6-55 32V 36V ~ ~ C6-TG48 CRC6-48 CRV6-55 42V 48V ~ 48 C6-TG482 CRC6-48 CRV6-55 48V 55V ~ 48 C6-TG44 CRC6-48 CRV6-55 0V 20V ~ 20B C6-TG473 CRC6-0 CRV6-36 ~ 208V ~ 208 C6-TG049 CRC6-240 CRV6-277 220-230V 240V ~ 240B C6-TG44 CRC6-240 CRV6-277 240V 277V ~ 277 C6-TG480 CRC6-240 CRV6-277 380V-400V 440V ~ 380 C6-TG07 CRC6-880 CRV6-575 45V 480V ~ 480 C6-TG475 CRC6-550 CRV6-575 440V 508V ~ ~ C6-TG478 CRC6-550 CRV6-575 500V 575V ~ 575 C6-TG479 CRC6-550 CRV6-575 550V 600V ~ 600 C6-TG476 CRC6-550 CRV6-575 Price 78 See page 33 for pricing C6.C. Coil (typical) Renewal Coils C6 Contactors Renewal Coils - D.C., Conventional Two-Winding Coil ➊➌ DC Control Voltages Conventional Coil DC Coil codes For use with contactor... C6-95 C6-0 C6-5, C6-40 C(N)6-80 Catalog No. Factory Integrated Varistor built into coil 2V 2D C6-TG708 Yes 24V 24D C6-TG74 Yes 48V 48D C6-TG724 Yes 0V 0D C6-TG733 Yes 25V 25D C6-TG737 Yes 220V 220D C6-TG76 Yes 240V ~ C6-TG750 Yes 250V 250D C6-TG75 Yes Price 24842 Items in grey are obsolete. ➊ Other coil voltages available. Contact your Sprecher + Schuh representative for information. ➋ Not factory installed, must be ordered separately. ➌ For conventional DC coils, the pickup winding must be connected to a NC late-break auxiliary contact. (See page 49) 34 Discount Schedule B6

Renewal Coils -.C., -EI Electronic Coil ➊➌➎ C Control Voltages EI Coil C Coil Codes ➋ C6-95-EI C6-0-EI C6-5-EI C6-40-EI C6-80-EI CN6-80-EI C6-20-EI C6-250-EI For use with contactor... C6-300-EI CN6-300-EI DISCONTINUED C6-420-EI C6-630-EI C6-860-EI EI Coil Suppressor Info Factory Integrated Suppressor on Coil Circuit Board ➌ Factory Installed External Suppressor Module ➌ 60 Hz 50/60 Hz Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. ~ 24V 24 C6-TGE855 C6-TGE855 ~ ~ No CRV6-40 ~ 42-64V 48 C6-TGE864 C6-TGE864 ~ ~ No CRV6-75 ~ 0-30V 20 C6-TGE865 C6-TGE865 C6-THE865 ~ Yes ~ ~ 208-277V 220W C6-TGE866 C6-TGE866 C6-THE866 ~ Yes ➍ ~ 380-500V 460W C6-TGE867 C6-TGE867 C6-THE867 ➑ ~ Yes RC 00N ➎ ~ 0-30V 20 ~ ~ ~ C6-TJE865 ➏ Yes ~ ~ 200-220V 208W ~ ~ ~ C6-TJE878 Yes ~ ~ 230-250V 240W ~ ~ ~ C6-TJE879 ➏ Yes ~ ~ 277V 277 ~ ~ ~ C6-TJE880 Yes ~ ~ 380-45V 380 ~ ~ ~ C6-TJE867 Yes ~ ~ 440-480V 480 ~ ~ ~ C6-TJE868 Yes ~ Price 42 42 565 882 Renewal Parts C6 Contactors C6.C. -EI coil (typical) C6 Contactors Renewal Coils - D.C., -EI Electronic Coil ➊➌➍ DC Control Voltage DC Coil Codes C6-95-EI C6-0-EI C6-5-EI C6-40-EI C6-80-EI CN6-80-EI C6-20-EI C6-250-EI For use with contactor... C6-300-EI CN6-300-EI C6-420-EI C6-630-EI C6-860-EI EI Coil Suppressor Info Factory Integrated Suppressor on Coil Circuit Board ➌ Factory Installed External Suppressor Module ➌ EI Coil Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. 24V ➐ 24D C6-TGE708 C6-TGE708 ~ ~ No CRV6-40 48-72V 48D C6-TGE779 C6-TGE779 ~ ~ No CRV6-55 0-30V 20D C6-TGE780 C6-TGE780 C6-THE780 ~ Yes ~ 200-255V 220D C6-TGE78 C6-TGE78 C6-THE78 ~ Yes ~ 0-30 20 ~ ~ ~ C6-TJE865 ➏ Yes ~ 200-255V 240W ~ ~ ~ C6-TJE879 ➏ Yes ~ Price 494 636 636 882 Items in grey are obsolete. ➊ Other coil voltages available. Contact your Sprecher + Schuh representative for more information. ➋ Coil Codes in bold letters and shaded indicate coils that are standard stocked items. ➌ Factory external suppressor module provided where shown, included with replacement coil. ➍ Factory integrated suppressor is overvoltage category III, for optional category IV, e.g. lightning protection, a CRV6-550 module can be added. ➎ Special capacitor module supplied on C6-420 only, not shown in catalog. ➏ Coil is rated C / DC. ➐ Customers with 24VDC applications should strongly consider using the EI functionality of the C6 (see page 48). ➑ Contactor manufactured with 380-500V coils can not be interchanged with any other coils because of the circuit board built into the base of the C6-420. Discount Schedule B6 35

C6 Contactors Main Contact - 3 Per Set (up to C6-420) DISCONTINUED Main Contacts (typical) For use with... Catalog Number Standard Terminal Hardware (screw & washer) ➊ Price/ Set C6-95 C6-C95 250 C6-95-EI C6-CE95 296 C6-0 C6-C0 3 C6-0-EI C6-CE0 3 C6-5 C6-C5 296 C6-5-EI C6-CE5 296 C6-40 C6-C40 474 C6-40-EI C6-CE40 474 C(N)6-80 C6-C80 565 C(N)6-80-EI C6-CE80 589 C6-20-EI C6-CE20 763 C6-250-EI C6-CE250 956 C(N)6-300-EI C6-CE300 40 C6-420-EI C6-CE420 640 Items in grey are obsolete and have limited availability. Renewal Parts C6 Contactors Main Contact & rc Chute - Complete Set (C6-630 and C6-860) Complete set of three each Main Contact, rc Chute and hardware For use with... Catalog Number Price/ Set C6-630-EI C6-CE-630 ➍ 2940 C6-860-EI C6-CE-860 ➍ 3980 Terminal Hardware Fits Contactor... Screw Type Catalog Number Price Each C6-95 & 0 M6 C6-HF0 27.70 C6-5(-EI), 40(-EI) & C(N)6-80(-EI) C6-20-EI, C6-250-EI, C(N)6-300-EI & C6-420-EI M8 C6-HF80 4.80 M0 C6-HF420 84.80 rc Chutes ➋➌ rc Chutes (typical) C6-630-EI to 860-EI M2 C6-HF860 28.00 Items in grey are obsolete and have limited availability. For use with... Catalog Number Price/ Set C6-95 C6-95 24 C6-95-EI C6-E95 24 C6-0 C6-0 67 C6-0-EI C6-E0 67 C6-5 C6-5 60 C6-5-EI C6-E5 60 C6-40 C6-40 87 C6-40-EI C6-E40 206 C(N)6-80 C6-80 244 C(N)6-80-EI C6-E80 244 C6-20-EI C6-E20 456 C6-250-EI C6-E250 543 C(N)6-300-EI C6-E300 634 C6-420-EI C6-E420 76 Items in grey are obsolete and have limited availability. ➊ Set of six (6). Priced per set. ➋ One () required per contactor. ➌ C6- W rc Chutes available by special order. ➍ Kit includes Main Contacts and rc Chute Chamber. 36 Discount Schedule B6

DISCONTINUED Contactors Cross Reference, Series C & C6 to Series C9 (Open Type Only) ➊ Obsolete Contactor Cross Reference C or C6 to C9 Contactors Ratings for Switching C Motors (C2 / C3 / C4) Series C Series C6 Series C9 I e [] kw (50 Hz) UL/CS HP (60 Hz) Obsolete Obsolete Equivalent 400V / Ø 3 Ø Catalog Catalog Catalog C-3 C- 230V 45V 500V 690V 5V 230V 200V 230V 460V 575V Number Number Number 5 250 37 64/66 80 0 25 40 40 75 00 C6-5 6 60 30 55 75 55 30 40 75 00 6 0 25 40 40 75 00 C-60 40 250 45 78/82 80 5 30 40 50 00 25 C6-40 46 225 45 75 90 90 40 50 00 25 46 5 30 50 50 00 25 C-00 80 250 57 0/05 98 35 ~ 40 50 60 50 50 C6-80 90 275 55 90 90 32 50 60 25 50 90 ~ ~ 60 60 50 50 C-50 205 350 55 0 0 60 60 75 50 200 205 20 350 67 8/22 47 205 ~ 50 60 75 50 200 C6-20 ~ ~ 75 00 200 250 C-250 250 350 80 40/45 77 250 ~ ~ 75 00 200 250 C6-250 265 400 75 32 60 200 75 00 200 250 265 300 450 97 70/76 23 293 ~ ~ 00 25 250 300 C6-300 305 500 90 60 200 250 00 25 250 300 305 ~ ~ 50 50 350 400 C-480 400 600 0 200/220 250 35 25 50 350 400 400 420 500 35 238/250 298 424 ~ ~ 50 75 350 400 C6-420 460 700 32 250 35 355 50 200 400 500 460 580 800 60 35/355 400 500 200 250 500 600 580 630 800 200 355 450 500 ~ ~ 200 250 500 600 C6-630 750 050 220 400/425 520 600 250 300 600 700 750 860 000 250 500 560 ~ ~ ~ 250 300 600 700 C6-860 860 350 257 475/500 560 800 ~ 400 800 000 860 C6 Contactors C-0 Contactor C6-40-EI contactor ➊ vailable auxiliary contacts may vary. See selection pages for more information. 37

DISCONTINUED Technical Information C6 Contactors C6 Contactors Technical Information Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 UL; CS [V] [V] C6-5(-EI) C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI 000V 600V C6-300-EI Rated Voltage U imp (kv) 2kV Rated Voltage U e - Main Contacts C 50/60Hz [V] 230, 240, 400, 45, 500, 690, 000V DC [V] 24, 48, 0, 220, 440V Operating Frequency for C Loads [Hz] 50/60Hz C6-420-EI C6-630-EI C6-860-EI Switching Motor Loads Standard IEC Ratings C-2, C-3 230V [] 5 40 80 20 250 300 420 630 860 DOL & Reversing 240V [] 5 40 80 20 250 300 420 630 860 50Hz 400V [] 5 40 80 20 250 300 420 630 860 45V [] 5(30)➊ 40(55)➊ 80(89)➌ 20(227)➊ 250(258)➊ 300(35)➊ 420 630 860 500V [] 5 5/40➋ 40(80)➊ 20 250 300 420 630 753 690V [] 5 5/40➋ 40(80)➊ 20 250 300 420 492 ~ 000V [] 46 55 65 80 95 5 60 ~ ~ 230V [kw] 37 45 57 67 80 97 35 200 250 240V [kw] 38 47 60 70 83 0 4 200 250 400V [kw] 64 78 0 8 40 70 238 355 500 45V [kw] 66(75)➊ 82(90)➊ 05(0)➊ 22(32)➊ 45(50)➊ 76(85)➊ 250 355 500 500V [kw] 80 80(98)➋ 98(26)➊ 47 77 23 298 450 560 600V [kw] /35➋ 35(76)➊ 205 250 293 424 500 ~ 000V [kw] 63 75 90 0 32 60 225 ~ ~ UL/CS 5V [] 00 35 ~ ~ ~ ~ ~ ~ ~ DOL & Reversing 230V [] 0 36 76 26 ~ ~ ~ ~ ~ 60Hz 5 V [HP] 0 5 ~ ~ ~ ~ ~ ~ ~ 230 V [HP] 25 30 40 50 ~ ~ ~ ~ ~ 200V [] 20 20 50 77 22 285 44 552 692 230 V [] 04 30 54 92 248 32 420 602 720 460 V [] 96 24 80 80 240 302 44 590 702 3 575 V [] 99 25 44 92 242 289 382 562 65 200 V [HP] 40 40 50 60 75 00 50 200 250 230 V [HP] 40 50 60 75 00 25 75 250 300 460 V [HP] 75 00 50 50 200 250 350 500 600 575 V [HP] 00 25 50 200 250 300 400 600 700 C4 (200,000 Op. Cycles) 230V [] 53 60 67 85 05 40 70 ~ ~ 50Hz 240V [] 53 60 67 85 05 40 70 ~ ~ 400/45V [] 53 60 67 85 05 40 70 ~ ~ 500V [] 53 60 67 85 05 40 70 ~ ~ 690V [] 53 60 67 85 05 40 70 ~ ~ 000V [] 25 37 43 60 72 85 05 ~ ~ 230V [kw] 5 7 20 25 32 45 55 ~ ~ 240V [kw] 5 8.5 22 25 32 45 55 ~ ~ 400/45V [kw] 25 32 37 45 / 50 55 75 /80 90 / 00 ~ ~ 500V [kw] 32 40 45 55 75 00 0 ~ ~ 690V [kw] 45 55 63 80 00 32 60 ~ ~ 000V [kw] 30 50 55 80 00 0 50 ~ ~ Max. Operating Rate [ops/hr] 20 20 00 20 00 70 70 ~ ~ ➊ Values in ( ) represent ratings for C-2 & C-3 and result in reduced lifespan of 25%. Use 400V values for full life span. ➋ Second number is rating for the -EI model. 38

Electrical Data C6-5(-EI) DISCONTINUED C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI Technical Information C6-420-EI C6-630-EI Switching Motor Loads (continued) Wye-Delta (Star Delta) 230V [] 99 242 32 364 433 520 727 ~ ~ 50Hz 240V [] 99 242 32 364 433 520 727 ~ ~ 400V [] 99 242 32 364 433 520 727 ~ ~ 45V [] 99(225) 242(268)➊ 32(332) 364(393)➊ 433(447)➊ 520(546)➊ 727 ~ ~ 500V [] 99 99 / 242➋ 32 364 433 520 727 ~ ~ 690V [] 99 99 / 242➋ 32 364 433 520 727 ~ ~ 000V [] 80 95 3 39 65 200 277 ~ ~ 230V [kw] 63 75 90 0 32 60 220 ~ ~ 240V [kw] 66 80 00 25 50 60 250 ~ ~ 400V [kw] 0 32 60 200 250 300 425 ~ ~ 45V [kw] 4(32)➊ 32(60)➊ 60 220 250 35(335)➊ 425➊ ~ ~ 500V [kw] 32 32 / 60➋ 200 250 35 375 530 ~ ~ 690V [kw] 92 200 / 220➋ 300 355 425 530 750 ~ ~ 000V [kw] 00 32 60 200 220 280 400 ~ ~ 60 Hz 200V [HP] 60 60 75 00 25 75 250 ~ ~ 230V [HP] 60 75 00 25 75 200 250 ~ ~ 460V [HP] 25 75 200 250 350 450 600 ~ ~ 575V [HP] 50 200 250 300 450 500 650 ~ ~ UL/CS Elevator Duty 200V [] 78 92 20 50 50 77 22 ~ ~ 230V [] 80 04 30 30 54 92 248 ~ ~ 460V [] 77 96 24 56 80 80 240 ~ ~ 575V [] 77 77 99 25 44 92 242 ~ ~ 200V [HP] 25 30 40 50 50 60 75 ~ ~ 230V [HP] 30 40 50 50 60 75 00 ~ ~ 460V [HP] 60 75 00 25 50 50 200 ~ ~ 575V [HP] 75 75 00 25 50 200 250 ~ ~ C- Load, 3 Switching I th [] 250 250 250 350 350 450 540 800 000 mbient Temperature 40 C 230V [kw] 00 00 00 39 39 79 99 39 398 240V [kw] 04 04 04 45 45 87 208 333 46 400V [kw] 73 73 73 242 242 32 346 554 693 45V [kw] 80 80 80 252 252 323 359 575 79 500V [kw] 27 27 27 303 303 390 433 693 866 690V [kw] 299 299 299 48 48 538 598 956 95 000V [kw] 433 433 433 606 606 779 866 ~ ~ mbient Temperature 60 C I th [] 20 20 20 300 300 380 425 ~ ~ 230V [kw] 84 84 84 20 20 5 69 ~ ~ 240V [kw] 87 87 87 25 25 58 77 ~ ~ 400V [kw] 45 45 45 208 208 263 294 ~ ~ 45V [kw] 5 5 5 26 26 273 305 ~ ~ 500V [kw] 82 82 82 260 260 329 368 ~ ~ 690V [kw] 25 25 25 359 359 454 508 ~ ~ 000V [kw] 364 364 364 520 520 658 736 ~ ~ C6 Contactors C6-860-EI C6 Contactors ➊ Values in ( ) represent ratings for C3 & C4 and result in reduced lifespan of 25%. Use 400V values for full life span. ➋ Rating C6-40 / C6-40-EI. 39

C6 Contactors Electrical Data C6-5(-EI) DISCONTINUED C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI C6-420-EI C6-630-EI Technical Information C6-860-EI Continuous Current (UL/CS) General Purpose Rating (40 C) Open [] 250 250 250 350 350 420 500 760 000 Enclosed [] 220 220 220 300 300 340 420 630 860 Lighting Loads Elect.Dischrg.Lamps-C-5a, Open [] 44 225 225 35 35 405 450 ~ ~ single compensated Enclosed [] 22 89 89 270 270 342 383 ~ ~ Incandescent Lamps - C-5b [] 20 40 70 20 250 300 420 ~ ~ Switching power transformers C-6a Inrush Rated transformer current, P e n=30 240VC [] 60 70 85 05 25 50 20 ~ ~ 230 VC [kv] 24 28 34 42 50 60 84 ~ ~ 240 VC [kv] 26 29 35 44 52 62 87 ~ ~ 400 VC [kv] 42 48 59 73 87 04 45 ~ ~ 45 VC [kv] 43 50 6 75 90 08 5 ~ ~ 500 VC [kv] 52 6 74 9 08 30 82 ~ ~ 690 VC [kv] 72 84 02 25 49 79 25 ~ ~ 000 VC [kv] 80 2 47 82 27 260 364 ~ ~ n = 20 690 VC [] 90 05 28 58 88 225 35 ~ ~ n = 5 690 VC [] 20 40 70 20 250 300 420 ~ ~ 60Hz Peak inrush/peak rated transformer n = 30 [] 60 70 85 05 25 50 20 ~ ~ 200V [kv] 20.8 24.2 29.4 36.4 43.3 52.0 72.7 ~ ~ 208V [kv] 2.6 25.2 30.6 37.8 45.0 54.0 75.7 ~ ~ 240V [kv] 24.9 29. 35.3 43.6 52.0 62.4 87.3 ~ ~ 480V [kv] 49.9 58.2 70.7 87.3 04 25 75 ~ ~ 600V [kv] 62.4 72.7 88.3 09 30 56 28 ~ ~ 660V [kv] 68.6 80.0 97.2 20 43 7 240 ~ ~ 60Hz Peak inrush/peak rated transformer n = 20 [] 90 05 28 58 88 225 35 ~ ~ 200V [kv] 3.2 36.4 44.3 54.7 65. 77.9 09 ~ ~ 208V [kv] 32.4 37.8 46. 56.9 67.7 8. 3 ~ ~ 240V [kv] 37.4 3.6 53.2 65.7 78.2 93.5 3 ~ ~ 480V [kv] 74.8 87.3 06 3 56 87 262 ~ ~ 600V [kv] 93.5 09 33 64 95 234 327 ~ ~ 660V [kv] 03 20 46 3 25 257 360 ~ ~ 60Hz Peak inrush/peak rated transformer n = 5 [] 20 40 70 20 250 300 420 ~ ~ 200V [kv] 4.6 48.5 58.9 72.7 86.6 04 45 ~ ~ 208V [kv] 43.2 50.4 6.2 75.7 90. 08 5 ~ ~ 240V [kv] 49.9 58.2 70.7 87.3 04 25 75 ~ ~ 480V [kv] 99.8 6 4 75 208 249 349 ~ ~ 600V [kv] 25 45 77 28 260 32 436 ~ ~ 660V [kv] 37 60 94 240 286 343 480 ~ ~ C6 Contactors 40

Electrical Data DISCONTINUED C6-5(-EI) C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI C6-420-EI Technical Information C6-630(EI DC Ratings DC- Rating at 60 C Non-inductive or slightly 24VDC [] 35 20 20 300 300 380 425 ~ ~ inductive loads, resistive 48VDC [] 35 20 20 300 300 380 425 ~ ~ furnaces 0VDC [] 35 20 20 300 300 380 425 ~ ~ 220VDC [] 3 3.3 3.3 4.9 4.9 4.9 5.2 ~ ~ Pole 440VDC [] 0.6 0.75 0.75.2 ~ ~ 24VDC [] 35 20 20 300 300 380 425 ~ ~ 48VDC [] 35 20 20 300 300 380 425 ~ ~ 2 Poles in Series 0VDC [] 35 20 20 300 300 380 425 ~ ~ 220VDC [] 35 20 20 300 300 380 425 ~ ~ 440VDC [] 3 3.3 3.3 4.9 4.9 4.9 5.2 ~ ~ 24VDC [] 35 20 20 300 300 380 425 ~ ~ 48VDC [] 35 20 20 300 300 380 425 ~ ~ 3 Poles in Series ➊ 0VDC [] 35 20 20 300 300 380 425 ~ ~ 220VDC [] 35 20 20 300 300 380 425 ~ ~ 440VDC [] 4 4 4 5 ~ ~ C6 Contactors C6-860-EI C6 Contactors DC-3 Rating at 60 C Shunt wound motors - 24VDC [] 35 20 20 300 300 380 425 ~ ~ Starting, reverse current 48VDC [] 35 20 20 300 300 380 425 ~ ~ breaking, reversing, stepping 0VDC [] 35 20 20 300 300 380 425 ~ ~ 220VDC [] 35 20 20 300 300 380 425 ~ ~ 3 Poles in Series ➊ 440VDC [] 3 3.5 3.5 4. 4. 4. 5.8 ~ ~ DC-5 Rating at 60 C Series wound motors - 24VDC [] 35 20 20 300 300 380 425 ~ ~ Starting, reverse current 48VDC [] 35 20 20 300 300 380 425 ~ ~ breaking, reversing, stepping 0VDC [] 35 20 20 300 300 380 425 ~ ~ 220VDC [] 35 20 20 300 300 380 425 ~ ~ 3 Poles in Series ➊ 440VDC [].2 2. 2. 2.4 2.4 2.4 3.0 ~ ~ Three poles wired in series for DC switching + OPTION OPTION B ➊ See diagram to right for three poles wired in series for DC switching 4

C6 Contactors Electrical Data C6-5(-EI) C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI C6-420-EI C6-630-EI Capacitor Ratings C-6b Capacitor Switching - 50Hz Single Capacitor - 40 C 230 V [kvar] 45 70 70 98 98 25 39 ~ ~ 240 V [kvar] 47 73 73 02 02 3 45 ~ ~ 400 V [kvar] 78 2 2 70 70 28 242 ~ ~ 45 V [kvar] 8 26 26 76 76 226 252 ~ ~ 500 V [kvar] 97 52 52 22 22 273 303 ~ ~ 690V [kvar] 34 209 209 293 293 376 48 ~ ~ 000 V [kvar] 94 303 303 424 424 546 606 ~ ~ Single Capacitor - 60 C 230 V [kvar] 38 59 59 84 84 06 9 ~ ~ 240 V [kvar] 39 6 6 87 87 24 ~ ~ 400 V [kvar] 65 02 02 45 45 84 206 ~ ~ 45 V [kvar] 68 06 06 5 5 9 24 ~ ~ 500 V [kvar] 82 27 27 82 82 230 258 ~ ~ 690V [kvar] 3 76 76 25 25 38 356 ~ ~ 000 V [kvar] 64 255 255 364 364 46 55 ~ ~ Capacitor Bank- 40 C 230 V [kvar] 45 70 70 98 98 25 39 ~ ~ 240 V [kvar] 47 73 73 02 02 3 45 ~ ~ 400 V [kvar] 56 76 70 70 28 242 ~ ~ 45 V [kvar] 56 76 2 70 76 226 252 ~ ~ 500 V [kvar] 56 76 3 72 22 273 303 ~ ~ 690V [kvar] 57 78 4 74 247 356 48 ~ ~ 000 V [kvar] 58 79 6 77 25 36 606 ~ ~ Capacitor Bank- 60 C 230 V [kvar] 38 59 59 84 84 06 9 ~ ~ Capacitor Switching - 60Hz DISCONTINUED 240 V [kvar] 39 6 6 87 87 24 ~ ~ 400 V [kvar] 56 76 02 45 45 84 206 ~ ~ 45 V [kvar] 56 76 06 5 5 9 24 ~ ~ 500 V [kvar] 56 76 3 72 82 230 258 ~ ~ 690V [kvar] 57 78 4 74 247 38 356 ~ ~ 000 V [kvar] 58 79 6 77 25 36 55 ~ ~ Single Capacitor - 40 C 200 V [kvar] 39 6 6 85 85 09 2 ~ ~ 230 V [kvar] 45 70 70 98 98 25 33 ~ ~ 460 V [kvar] 89 39 39 95 95 25 279 ~ ~ 600V [kvar] 6 82 82 255 255 327 364 ~ ~ Capacitor Bank- 40 C 200 V [kvar] 39 6 6 85 85 09 2 ~ ~ 230 V [kvar] 45 70 70 98 98 25 39 ~ ~ 460 V [kvar] 56 76 2 7 95 25 279 ~ ~ 600V [kvar] 57 77 4 73 246 327 364 ~ ~ Technical Information C6-860-EI C6 Contactors 42

DISCONTINUED Technical Information C6 Contactors Electrical Data Short-Circuit Coordination Contactors without Motor Protection Relays C6-5(-EI) C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI C6-420-EI C6-630-EI C6-860-EI DIn Fuses - gg, gl vailable Fault Current [] 00 K 00 K 00 K 00 K 00 K 00 K 00 K ~ ~ Type [] 250 35 35(355) 500 500 630 630 ➊ ➊ Type 2 (380/400/45/690V) ➍ [] 200 250 250(35) 400 400 500 500 Type 2 (000V) ➍ [] 200 250 250(35) 400 400 500 500 cul Short-Circuit Ratings Class K, RK, K5, and RK5 Fuses (L Fuses) vailable Fault Current [] 0 K 0 K 0 K 0 K 8 K 8 K 8 K 30 K 42 K cul Max. Rating (600V) ➌ Type [] 250 350 450 500 L-700 L-700 L-000 L-2000 L-2500 Class J CS & HRCI-J Fuses ➋ vailable Fault Current [] 00 K 00 K 00 K 00 K 00 K 00 K 00 K ~ ~ cul Max. Rating (600V) ➌ Type 2 [] 200 250 300 400 400 500 600 ~ ~ Circuit Breaker, inverse time ➎ vailable Fault Current [] 0 K 0 K 0 K 0 K 8 K 8 K 8 K 30 K 42 K cul Max. Rating (600V) ➌ Type [] 50 200 250 300 350 400 500 200 200 Short Time Current Withstand Ratings l cw 60 C S [] 800 800(2550) ➋ 2550 3405 3870 4725 6376 ➊ ➊ 4 S [] 500 800(970) ➋ 970 350 3870 400 6376 0 S [] 040 240(360) ➋ 480 2360 2520 2840 4700 6300 7000 5 S [] 860 860 (30) ➋ 30 2000 20 2270 3460 60 S [] 650 650 (850) ➋ 850 25 300 500 880 ➊ ➊ 240 S [] 340 340 (600) ➋ 600 705 750 840 280 900 S [] 240 250 (440) ➋ 440 460 500 590 840 Off Time Between Operations [Min.] 20 20 20 30 30 30 30 Resistance and Watt Loss I e C3 Resistance per power pole [mw] 0.4 0.42 0.42 0.22 0.22 0.8 0.5 0.9 0.4 Watt Loss - 3 power poles [W] 4.5 24.6 40.8 29.4 4.7 48.6 79.4 226.2 30.6 Coil and 3 power poles C [W] 24.5(20.5)➋ 34.6(30.6)➋ 50.8(46.8)➋ 35.4 47.7 54.6 86.5 256.2 340.6 (@I ec3) DC [W] 22.5(20.5)➋ 32.6(30.6)➋ 48.8(46.8)➋ 35.4 47.7 54.6 86.5 256.2 340.6 C6 Contactors ➊ Under test. Contact your Sprecher + Schuh representative. ➋ Values in parentheses (_) are for the -EI- contactor. ➌ UL Listed Combination. (UL File E4850) Per UL508, NEC409 and CS 22.2 No.4 for contactor and fuses or circuit breaker only. ➍ Per IEC 60947- for contactor and fuses only. ➎ When used as a Branch Circuit Protection device, NEC 430-52 defines the maximum rating of an Inverse-time circuit breaker to be sized at 250% of the motor nameplate FL for most applications. 43

C6 Contactors Short Circuit Ratings High Fault Short Circuit Ratings per UL508 and CS 22.2 No.4 CEP7 Second Generation Cat. No. CEP7 EEHF EEJF EEJG EEKG Contactor Catalog No. Max. starter FLC () DISCONTINUED Max. available fault current (k) Fuse Ratings Max. voltage (V) UL Class J and CS HRCI-J fuse () C6-5 5 CN6-5 00 600 200 C6-40 40 250 C6-80 CN6-80 80 00 600 300 C6-20 20 400 C6-250 250 00 600 400 C6-300 CN6-300 300 500 C6-20 20 400 C6-250 250 00 600 400 C6-300 CN6-300 300 500 EELG C6-420 420 00 600 600 Technical Information C6 Contactors & Overload Relay UL Listed Circuit Breaker Ratings ➊ Short Circuit Rating (k) 65 25 65 25 65 30 65 30 42 25 Max. Voltage (V) 480 600 480 600 480 600 480 600 480 600 Max. CB rating () 250 250 400 400 600 ➊ Various Mfg. of UL Listed Circuit Breakers may be used. 44

Mechanical Data C6-5 C6-5-EI C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI Technical Information C6-300-EI C6-420-EI C6 Contactors Service Life Mechanical C [Mil.] 0 0 0 0 0 0 0 0 2 2 DC [Mil.] 0 0 0 0 0 0 0 0 2 2 Electrical C-3 (400V) [Mil.] R/F R/F Shipping Weights C - C6 [kg] 3.3 3.8 3.3 (3.8) 3.3 (3.8) 7.5 7.5 7.5 7.5 28.6 28.6 [Lbs] 7.3 8.38 7.3 (8.4) 7.3 (8.4) 6.5 6.5 6.5 6.5 63 63 DC - C6 [kg] 3.3 3.8 3.3 (3.8) 3.3 (3.8) 7.5 7.5 7.5 7.5 28.6 28.6 [Lbs] 7.28 8.38 7.3 (8.4) 7.3 (8.4) 6.5 6.5 6.5 6.5 63 63 Terminations - Power Type Direct Connection DISCONTINUED C6-630-EI Hexagonal Bolt b max. [mm] 25 30 52 C6-860-EI C6 Contactors c max. [mm] 2.5 5 22 s max. [mm] 5 6 2 x 8 Ø min. [mm] 8.3 0.5 3 Recommended Torque [Nm] 22 43 68 [Lb-in] 95 380 600 With Main Terminal Set (C6-HB...) sm. opening [mm 2 ] 6...35 25...85 ~ lg. opening [mm 2 ] 6...95 25...85 ~ sm. opening [mm 2 ] 6...50 25...240 ~ lg. opening [mm 2 ] 6...20 25...240 ~ b max. [mm] 20 25 ~ s. sm. opening [mm] 3...9 6...20 ~ s. lg. opening [mm] 3...4 6...20 ~ Recommended Torque [Nm] 4 25 ~ Wire Size per UL/CS sm. opening [WG] #6... / 0 #4...600MCM ~ lg. opening [WG] #6...250MCM #4...600MCM ~ Recommended Torque [Lb-in] 24 220 ~ ➊ Minimum 25mm 2 (#4 WG) -95mm 2 (250mcm) with sleeve per DIN 46228. 45

C6 Contactors Mechanical Data (continued) Technical Information C6- C6- C6- C6- C6- C6- C6- C6- C6-5(-EI) 40(-EI) 80(-EI) 20-EI 250-EI 300-EI 420-EI 630-EI 860-EI With Screw-type Lugs - Copper Clad (C6-L ) Screw-type lugs accept round conductors only C6-L80 [WG] #6 300 MCM ~ ~ ~ Recommended Torque [Lb-in] 88 06 ~ ~ ~ C6-L420 [WG] ~ 2x #4 350 MCM ~ ~ Recommended Torque [Lb-in] ~ 375 ~ ~ C6-L630 [WG] ~ ~ 2 x 2 / 0 500 MCM ~ Recommended Torque [Lb-in] ~ ~ 400 ~ C6-L860 [WG] ~ ~ ~ 4 x 2 / 0 500 MCM Recommended Torque [Lb-in] ~ ~ ~ 400 Terminations - Control DISCONTINUED C6 Contactors Description Combination Screw Head: Cross, Slotted, Pozidrive Coils Wires or 2 [mm2] 2.5 [WG] 6 2 Torque Requirement [Nm].5 [Lb-in] 8.9 3 Control Modules Wires [mm2] 4 [WG] 6 2 Degree of Protection - contactor IP00 per IEC 60529 and DIN 40 050 Type of Protection - with accessories Single contactor cover IPX per IEC 60529 and DIN 40 050 With main terminal set IP2X per IEC 60529 and DIN 40 050 Protection against accidental contact Finger and back-of-hand proof according to VDE 006, Part 00 46

DISCONTINUED Technical Information C6 Contactors Coil Data C6- C6- C6- C6-5 80 5-EI 300-EI 420-EI 630-EI 860-EI Voltage Range Conventional Coil EI Coil EI Coil EI Coil C: 50Hz, 60Hz, 50/60 Hz Pickup [x U s ] 0.85. 0.85 U s min. U s max 0.85 U s min. U s max 0.80 U s min. U s max Dropout [x U s ] 0.3 0.6 0.3 U s min 0.5 U s max 0.3 U s min 0.5 U s max 0. U s min 0.8 U s max DC Pickup [x U s ] 0.85. 0.85 U s min. U s max 0.85 U s min. U s max 0.85 U s min. U s max Dropout [x U s ] 0.30 0.6 0.3 U s min 0.5 U s max 0.3 U s min 0.5 U s max 0. U s min 0.8 U s max Coil Consumption C: 50Hz, 60Hz, 50/60 Hz Pickup [V/W] 650 / 30 380 / 240 ➌ 490 / 270 ➌ 95 / 720 Hold-in [V/W] 50 / 0 3 / 6 8 / 7 33 / 30 DC Pickup [W] 540 ➊➋ 265 ➊➌ 340 ➊➌ 980 ➊➌ Hold-in [W] 8 6 7 30 EI (B-B2 24VDC Interface) [V/W] ~ 5 ma 5 ma 5 ma Operating Times C: 50Hz, 60Hz, 50/60 Hz Pickup [ms] 20 47 20 45 60 00 Dropout [ms] 6 2 25 0 70 45 with RC Suppressor Dropout [ms] 9 8 ~ ~ DC Pickup [ms] 27 47 25 50 60 00 with Integ. Suppression Dropout [ms] 2 20 35 0 70 45 Insulation Class Class B according to VDE 0660, Table 22 C6 Contactors C6-EI pplication Notes for 24 volt C/DC Electronic Coils The C6-EI 24 VC or 24 VDC electronic coils are sensitive to voltage drops. These notes are provided to assist customers in control wiring methods and the selection of a power supply. < 0ms I peak = 25 amps Start-up peak < 00ms I mean = amps Pull-in values > 00ms I hold = 0.5 amps verage Hold-in values Circuit operation While the electronic coil is switching on, the power supply must deliver a peak of 25 amps. This period will not exceed 0ms. During the contactor closing period, the pull-in current of the coil drops to amps. This period will not exceed 00ms. fter approximately 80ms the demand of the electronic coil will be reduced to the holding value; which has an average of 0.5 amps. Power supply selection Use peak value (I peak ) for the selection of the power supply. regulated power supply is preferred. If an unregulated power supply is utilized then the no load value of the power supply must be less than 28 volts. dditional attention must be given to decrease the control wire resistance because unregulated power supplies have a high ripple voltage. Control Circuit Wiring To minimize wire resistance see the following: The wire gauge (cross-section) must be sufficient to allow a wire resistance of less than 50 milli-ohms for a regulated power supply and 00 milli-ohms for an unregulated power supply. For unregulated power supplies, 6 WG can be used for runs up to 25 feet (longer for regulated power supply). Consult Sprecher + Schuh for additional information if longer runs are required. Stranded wire should be fitted with ferrules. Terminations should be tightened within the recommended torque values. If multiple C6-EI contactors are used in the control circuit, the electronic coil terminations should be fed directly from the power supply (home runs). Do NOT parallel (jumper) multiple coil terminations. Switching of the home runs must be accomplished through separate (individual) contacts of a control relay or control device. Recommendation C6 contactor used in the EI mode removes the burden of the coil from the 24 VDC power supply. The integrated electronic interface allows line voltage, or at least a higher C voltage (i.e., 20V), to be applied to coil terminals 2, while the 24 VDC low level milli-ampere signal switches the B B2 interface. The EI mode (method) has significant advantages over direct coil switching at 24 VDC. See the description of operation on the next page. ➊ Customers with 24VDC applications should strongly consider using the EI functionality of the C6 (see pages 48-49). ➋ Conventional DC coils are Two-Winding Coils. See page 49. ➌ Electronic coil drives are designed to minimize power requirements, but this control may exhibit higher inrush (540W, <0ms) when energizing. This must be taken into account for the proper sizing of supply devices, all-or-nothing relays, and cross-sections of coil supply lines. 47

DISCONTINUED Technical Information C6 Contactors C6 Contactors C6 Electronic Coils (C6-5-EI C6-860-EI) C6-EI contactors are supplied with an electronically controlled mechanism, which has an integrated electronic interface that consists of the following main parts: The coil bobbin rated for the control voltage. printed circuit board with components for control and interface functions which is matched to the coil and rated for the control voltage. n interconnecting printed circuit board with coil terminals, which is located in the contactor base. R/C transient surge suppressors which are installed on the printed circuit board. The C6-EI coil bobbin and printed circuit board are a matched set; therefore, both must be changed when replacing the coil or changing out the coil to a different voltage. ll replacement coils include both the coil bobbin and printed circuit board. Commissioning The C6-EI contactor is operated in either the E mode (normal operation) or the EI mode (electronic interface operation) and is programmed by an orange jumper located on the bottom side of the contactor (opposite the coil terminals). This orange jumper is directly underneath main terminal T2 and is exposed by removing the small plastic cover that shields the mating space for the CRC/CRV protection element. Electronic Operation E Mode For the E mode (factory default setting), the contactor is connected and controlled using terminals & 2 in the same manner as a traditional contactor with an electromechanical coil mechanism. The contactor is programmed from the factory in the E mode by means of the orange jumper in the position as shown in Detail. The E mode (or electronic mode) provides electronic control of the coil mechanism, but does not allow coil energizing from a low level signal source such as a PLC. Electronic Interface Operation EI Mode For the EI mode, or optional electronic interface setting, the contactor can be switched from a PLC or other low-level signal source (3 30.2 VDC) without the need for an interposing relay. The contactor is programmed for the EI mode by moving the orange jumper to the position as shown in Detail B. In the EI mode, the control voltage (VC or VDC) must be permanently switched on to terminals & 2 while in operation. The control signal from the PLC or other low-level signal source must be applied to terminals B & B2 (orange terminals) of the electronic interface in order to energize the contactor. The current burden of the interface is 5m maximum. 48

DISCONTINUED Technical Information C6 Contactors C6 Conventional DC Coil (C6-5 C6-80) Conventional 3-lead DC Coil C6 Contactors Notes ) The C6 conventional DC coil has dual windings with three leads brought out. One winding is the pick-up winding and the other is the holding winding. The coil also has a built-in voltage limiting varistor (Z). 2) The pick-up winding has low resistance while the holding winding has a higher resistance. 3) When the control circuit is energized, the contactor pulls-in through the lower resistance pick-up winding and the NC late break auxiliary contact. fter the contactor seals in, the late break contact opens and the contactor is held in through the holding winding. 4) The pick-up winding is not designed for continuous operation and must be disconnected by the late break contact immediately after the contactor pulls-in. 49

C6 Contactors Environmental and General Specifications C6-5(-EI) C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI C6-420-EI mbient Temperature ➊ Storage -55...+80 C (-67...76 F) Operation at rated current -25...+60 C (-3...40 F) (40 C per UL) Conditioned 5% current reduction -70 C (58 F) ltitude at installed site 2000 meters above sea level per IEC 60947- Resistance to Corrosion / Humidity Damp-alternating climate: cyclic to IEC 68-2, 56 cycles. Dry heat: IEC 68-2, +00 C (22 F), relative humidity <50%, 7 days Damp tropical: IEC 68-2, +40 C (04 F), relative humidity <92%, 56 days. Shock Resistance IEC 60068-2-27: Half sinusoidal shock ms, 4g (2g in all three directions) Vibration Resistance IEC 60068-2-6: Static >2g, in normal position Operating Position See Dimensions pages Standards IEC/EN 60947-/-4-/-5-; UL508; CS 22.2 No. 4 pprovals CE, culus, CCC uxiliary Contacts DISCONTINUED Technical Information C6-630-EI Conventional auxiliary contacts Suitable for electronic circuits Switching, C & DC Loads C- I th at 40 C [] 6 0. at 250V at 60 C [] 2 0. at 250V C-5 at rated operating voltage of: [V} 230 400 45 500 690 [] 5.5 3 2.5.6...00m at 3...25V DC-3, switching electromagnets at: [V} 24 48 0 220 440 [] 5 2 0.7 0.25 0.2...00m at 3...25V Short Circuit Protection - gg Fuse Type 2 Coordination [] 6 0. Rated Impulse Voltage U imp [kv] 8.5 Load carrying capacity per UL/CS Rated Voltage [V] 600 max. 250V max. Continuous Rating [] 0 general purpose Switching Capacity Heavy pilot duty (600) 0. Rated Voltage [V} 600 max. Switching Capacity Standard pilot duty (P600) Minimum Switching Capacity 7V, 0m 7V, 5m Terminals Terminal Type...2.5...2.5 Maximum Wire Size per IEC 947-...2.5...2.5 Flexible with Wire- Conductor [mm 2 ] End Ferrule 2 Conductor [mm 2 ]...4...4 Solid/Stranded- Conductor [mm 2 ] Conductor 2 Conductor [mm 2 ]...4...4 Recommended Tightening Torque [Nm].4...2.3.4...2.3 Max. Wire Size per UL/CS [WG] 6...2 6...2 Recommended Tightening Torque [lb-in] 2...20 2...20 Degree of Protection IP2X per IEC 529 and DIN 40 050 C6 Contactors C6-860-EI Contact Ratings (Per UL508/NEM 600 & Q600) Standard Circuit Voltage Make (mps/v) Break (mps/v) Continuous mps 600 20C 240C 480C 650C 60/7200V 30/7200V 5/7200V 2/7200V 6/720V 3/720V.5/720V.2/720V 0 Q600 25DC 250DC 600C 0.55/69V 0.27/69V 0./69V 0.55/69V 0.27/69V 0./69V 2.5 ➊ mbient is the temperature outside the enclosure. 50

DISCONTINUED Technical Information C6 Contactors - Contact Life Life-Load Curves C- / C-3 0 C- / Non or slightly inductive loads, resistive furnaces; Ue= 400 VC C-3 / Starting and stopping of running motors C6-5(-EI) C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI C6-420-EI C-/C-3 C6 Contactors Contact Life (Millions of Operations) Instructions on How to read Life Curves can be found on page 8 0. 0 00 000 Rated operational current Ie C-3 [] (Dashed curves - - - - C- only, open) C-4 / Starting with inching and plugging; Ue= 400 VC C6-5(-EI) C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI C6-420-EI C-4 0 C-4 Contact Life (Millions of Operations) 0. 0.0 0 00 000 Rated operational current Ie C-4 [] NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 5

DISCONTINUED Technical Information C6 Contactors - Contact Life C6 Contactors Life-Load Curves C-3 (90%), C-4 (0%) 0 Mixed operation of squirrel-cage motors; Ue = 400 VC C-3 90% Starting and stopping of running motors C-4 0% Starting with inching or plugging C6-5(-EI) C6-40(-EI) C6-80(-EI) C6-20-EI C6-250-EI C6-300-EI C6-420-EI C-3/C-4 Contact Life (Millions of Operations) 0. 0 00 000 Rated operational current Ie C-3 / C-4 [] Contact Life for Mixed Utilization Categories C-3 and C-4 In many applications, the utilization category cannot be defined as either purely C-3 or C-4. In those applications, the electrical life of the contactor can be estimated with the following equation: 00 Heavy Duty Starting and Regular Short-time Operation C6-20-EI C6-250-EI C6-300-EI C6-40(-EI)/80(-EI) C6-5(-EI) C6-420-EI L mixed L ac3 L mixed = L ac3 / [+P ac4 x (L ac3 /L ac4 -)], where: pproximate contact life in operations for a mixed C-3/C-4 utilization category application. pproximate contact life in operations for a pure C-3 utilization category (from the C-3 life-load curve). Max. Starting / Loading time [s] 0 L ac4 P ac4 pproximate contact life in operations for a pure C-4 utilization category (from the C-4 life-load curve). Percentage of C-4 operations 0 00 000 0000 Starting Current / Short-time current [] NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 52

Maximum Operating Rates C-3 250ms start time Max. Operating Rate [Ops/hr] 5000 000 00 DISCONTINUED Technical Information C6 Contactors Operating Rates Squirrel cage motors; starting, switching off during running; Ue = 400 VC 250ms start time; 40% duty cycle C-3 C6-5(-EI) C6-40(-EI) C6-80(-EI) C6 Contactors 0 0 00 000 Rated operational current Ie [] C-3 sec. start time 5000 Squirrel cage motors; starting, switching off during running; Ue = 400 VC s start time; 40% duty cycle Max. Operating Rate [Ops/hr] 000 00 C6-5(-EI) C6-40(-EI) C6-80(-EI) C-3 0 0 00 000 Rated operational current Ie [] 53

DISCONTINUED Dimensions C6 Contactors C6 Contactors e e2 Series C6 & Series CU6 (Contactors & Reversing Contactors) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. c øe d e3 b e3 e4 d2 a ød c Catalog Number a b c c d d d2 e e e2 e3 e4 C6-5(-EI); 20 70 56 0.5 5.2 45 00 20 39 60 0 C6-40(-EI); C(N)6-80(-EI); M8 (4-3/4) (6-/6) (6-/8) (4-/32) (7/32) (5-/6) (3-5/6) (3/6) (-35/64) (6-9//64) (25/64) C6-20-EI C6-250-EI 55 205 80 0.5 6.5 80 30 25 48 93 2.5 C(N)6-300(-EI); C6-420-EI M0 (6-/8) (8-/6) (7-3/32) (4-/32) (9/32) (7-3/32) (5-/8) () (-7/8) (7-9/32) (3/64) C6-630-EI C6-860-EI 255 (0-3/64) 30 (2-7/32) 265 (0-7/6) 0.5 (4-/32) 0 (25/64) 230 (9-/6) 225 (8-55/64) M2 40 (-37/64) 70 (2-3/4) 29 (-29/64) 22 (55/64) Reversing Contactors & ccessories (+...) Contactor with... C6... Dimension [mm] Dimension [inches] - auxiliary contact block ➊ + S a a + S2 a + 3.5 mm each a + 9/32 each - reversing w/mechanical interlock a + a a + a - main terminal set HB2 b + 7mm each b + 9/64 each HB3 b + 8.5mm each b + /32 each - label holder c + 5mm c + 3/6 Mounting Position 90 90 25 5 ➊ No change of base dimensions with or 2 auxiliary contact blocks (S or S2). Each dimension increased by 3.5 mm to the a dimesions on the right hand side. 54

DISCONTINUED Technical Information C6 Contactors Notes C6 Contactors 55

C5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors of this rating. The entire line is modularly designed for easy inspection, contact replacement and coil change out. ll maintenance can be performed from the front so that mounting can be accomplished with no wasted space on the sides. The contactor for large horsepower applications The C5 series consists of four contactors in two frame sizes covering motors from 500 to 900 HP (at 460V/575V). This line is well suited for heavy industrial applications utilizing large machinery and equipment such as rock quarries and mines, or for any large horsepower application where a rugged and dependable contactor is needed. Specially designed shockfree contact system characteristic of contactors in this size class is to transmit intense impact forces during operation. This is caused by the heavy magnetic armatures of the core, which can cause contact bounce. C5 contactors, however, are designed so that the operating planes of the electromagnets and the contacts are opposed to each other by Direction of electromagnets (coil armature) Direction of main contacts 90. This results in a bounce-free contact system, increasing the contactor s mechanical life and raising contact reliability. Rugged and reliable massive steel framework supporting the magnet system ensures high stability in all applications. Low-wear materials for bearings and sliding surfaces, as well as generously dimensioned magnet-pole faces result in above average mechanical life with a minimum of maintenance. Despite their rugged construction, overall contactor weight has been reduced considerably permitting simpler panel construction and easier assembly. 280mm ( ) 000 00 334mm ( 3 3/6 ) 200 350 56

Unique coil feeder group offers many advantages C5-700 and 860 contactors are equipped with a special feeder group for the coil that accommodates C control voltages of 50 or 60Hz, and a wide range of DC voltages. djustable auxiliary contacts C5 contactors can be equipped with a maximum of four NO and four NC auxiliary contacts. In addition, the closing time of the auxiliary contacts (on C5-700 & 860 contactors) can be adjusted to meet individual control requirements. Two choices for interlocking reversing contactors Unique to the C5 range is the ability to mechanically interlock reversing contactors in either a horizontal or vertical orientation. This feature allows maximum flexibility when laying out panels. C5 Contactors This coil arrangement eliminates noise and provides very low pickup and hold-in current. In addition, the dropout time of the coil can be adjusted within one of three ranges. Normal Drop (50 to 200ms): for prompt reaction of contactor to a breaking command (factory setting). Delayed Drop (0.5 to s): where it is necessary for the contactor to be immune to short power supply interruptions or uncertain control devices. Fast Drop (about 20ms): for safety applications where instant dropout is required. Modular, convenient design The C5 line is modularly designed for easy inspection, coil change and contact replacement. Maintenance can be performed from the front so that mounting requires no additional space. Even with the installation of mechanical interlocks and auxiliary contact blocks, the units can be flush mounted side by side, saving panel space. dd-on fourth pole In many applications, the neutral also needs to be switched. ll C5 contactors can be fitted with a 4th pole on either the left or right side of the contactor. This switched neutral is available as an accessory that can easily be installed in the field. DISCONTINUED 4 5 Horizontal mechanical interlock Vertical mechanical interlock Simple main contact inspection and easy coil change 3 9 C5-700 Contactor 2 C5-000 Contactor 3 Coil Pair 4 Feeder Group 5 4th Pole (Neutral Switching) 6 uxiliary Contact Block 7 uxiliary Contact Block 8 Mechanical Interlock (horizontal) 9 Mechanical Interlock (vertical) 6 8 full range of C5 accessories is available, including a unique mechanical interlock that allows vertical mounting of contactors (see explanation above) 2 7 57

C5 Contactors DISCONTINUED Non-Reversing, Three Pole Contactors With C or DC Coil, Series C5 (Open type only) ➊➌ Ratings for Switching C Motors (C2 / C3 / C4) uxiliary I e [] kw (50 Hz) UL/CS HP (60 Hz) ➌ 3 Ø Contacts per Contactor 400V C-3 C- 230V 45V 500V 690V 200V 230V 460V 575V NO NC Open Type Catalog Number ➊➌ 700 000 220 400 500 630 200 250 500 500 2 2 C5-700-22-700 Contactors - C and DC Coil Price Three Pole Series C5 860 00 280 500 630 70 250 300 600 600 2 2 C5-860-22-4300 000 200 35 560 750 850 ~ ~ ~ ~ 2 C5-000-2-6700 C5-700-22 contactor 200 350 375 70 850 000 450 450 900 900 2 C5-200-2-20300 Note: C5 open-type contactors include terminal bolts. See page 60 for Lugs. C5-000-2 contactor Coil Codes ➊➋ C5-700 / 860 C & DC Voltage Range Coil Code 50 Hz 60 Hz VDC 20 0-20V 0-20V 00-0VDC 240 220-240V 220-240V 200-220VDC 380 380-45V 380-45V 345-380VDC 480 440-480V 440-480V 400-440VDC Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code C Coil Code See Coil Codes on this page C5-000 / 200 Voltage Range 50 Hz 60 Hz 0 0V 0V 220 220V 220V 380 380V 380V 440 440V 440V 480 440-480V 440-480V ➊ C5-700 and 860 contactors are equipped with coils that operate with both C and DC control voltages. C5-000 and 200 contactors operate with C control voltage input that is rectified for DC coil operation. See page 6. Consult factory for DC control voltage input. ➋ Other voltages available, see page 6. ➌ C5-000 horsepower ratings per IEC Utilization category C-3. See C5 Technical Data section for additional sizing information. Label does not bear a UL/CS horsepower rating. 58

uxiliary Contact Blocks (2 & 4 Pole) Contact Block Description NO NC 4-pole For mounting between T & T2 or between T2 & T3 djustable; provides normal, delayed or overlapping contacts ➊ Maximum two blocks per contactor ➋ lternate terminal marking tags included DISCONTINUED 2 2 ccessories Field Installable C5 Contactors Contact rrangement For use with... Catalog Number Price Standard terminal marking for mounting between T & T2 53 6 7 83 54 62 72 84 lternate terminal marking for mounting between T2 & T3 C5-700 C5-860 C5-EF22 ➋ 456 C5 Contactors 2-pole For side mounting on either side of the contactor Maximum four blocks per contactor ➌ lternate terminal marking tags included Standard terminal marking 53 6 83 7 54 62 84 72 C5-000 C5-200 C5-EB ➌ 725 l One supplied standard with contactor l Special two pole design; NO delayed make, NC l NO delayed make contact used for operation of the Feeder Group/Coil mechanism Delayed Make 3 32 43 44 C5-000 C5-200 C5-EBDC 799 2-pole Switched Neutral (4th Pole) ➍ 4th Pole 4th Pole mperes I th C- 500 For use with... Catalog Number Price C5-700 C5-860 C5-NP500/6 30 000 C5-700 C5-860 C5-000 C5-200 C5-NP000/6 480 C5-NP000/7 2230 ➊ Further information on adjustable contacts can be found under uxiliary Contacts in the C5 Technical Section. ➋ Contactor comes standard with one 4-pole aux contact block. ➌ In addition to one standard two-pole auxiliary contact block (C5-EB), C5-000 & 200 contactors are equipped from the factory with a special two pole auxiliary contact block (C5-EBDC). One of the poles is used for operation of the Feeder Group/Coil mechanism, the other NC contact is available for use. Two additional aux contact blocks may be added for a total of four. ➍ No UL or cul approval. 59

DISCONTINUED ccessories - Field Installable C5 Contactors Main Lugs C5 Contactors Lug or ccessory Description Wire Size Catalog Number Price Screw Type Lugs - (set of 6) For C5-700 For C5-860 For C5-000 & C5-200 ➊ (2) 3/0-750MCM (3) 2-600MCM (4) /0-750MCM C5-700-LU C5-860-LU C5-200-LU 424 0 270 Mechanical Interlock Kit Mechanical Latch For Horizontal Mounting of Contactors Interlock For use with... Catalog Number Price Latch For use with... Catalog Number Price C5-700 C5-860 C5-700/C5-860 C5-700/C5-000 C5-700/C5-200 C5-860/C5-000 C5-860/C5-200 C5-BM6H 757 C5-BM67H 230 C5-700 C5-860 C5-M6-380 C5-000 C5-200 C5-000/C5-200 C5-BM7H 430 For Vertical Mounting of Contactors C5-700 C5-860 C5-700/C5-860 C5-700/C5-000 C5-700/C5-200 C5-860/C5-000 C5-860/C5-200 C5-BM6V 757 C5-BM67V 230 C Coil Code C5-M6- Replace with Coil Code Voltage Range 50 Hz / 60 Hz 20 0V - 20V 240 220V - 240V 45 380V - 45V 480 440V - 480V C5-000 C5-200 C5-000/C5-200 C5-BM7V 430855 ➊ C5-000 is not UL Listed. 60

DISCONTINUED ll C5 contactor coils are made up of two parts; the Coil Pair and Feeder Group. When ordering replacement parts, usually assume the Coil Pair must be replaced. If control voltage changes, user must order Coil Pair and matching Feeder Group. Even though all C5 coils are designed for C input (DC input also available for C5-550 860 contactors), they are operated by a DC voltage supplied from a feeder group. lways order Renewal Parts C5 Contactors by the Coil Code matched to the actual control voltage available to the contactor. Further information on C5 coil pairs and feeder groups can be found in C5 Technical Information. C5 Contactors C & DC Coil Pairs & Feeder Groups (C5-550 to C5-860) ➊➋ C5-550 C5-700 & C5-860 Voltage Range COIL CODES Coil Pair Feeder Group Coil Pair Feeder Group 0-20V 50/60Hz TX734 TXS734 TY734 TYS734 20 00-0VDC (22.807.30-0) (22.807.204-0) (22.809.30-0) (22.809.204-0) 220-240V 50/60Hz TX747 TXS747 TY747 TYS747 240 200-220VDC (22.807.30-3) (22.807.204-3) (22.809.30-3) (22.809.204-3) 380-45V 50/60Hz TX779 TXS779 TY779 TYS779 380 345-380VDC (22.807.30-6) (22.807.204-6) (22.809.30-6) (22.809.204-6) 440-480V 50/60Hz TX780 TXS780 TY780 TYS780 480 400-440VDC (22.807.30-8) (22.807.204-8) (22.809.30-8) (22.809.204-8) Price 855 930 060 0 C Coil Pairs & Feeder Groups (C5-000 & C5-200) ➊➋ Voltage Range 0-5 Volts 50/60Hz 220-230 Volts 50/60Hz 380-400 Volts 50/60Hz 440 Volts 50/60Hz 440-480 Volts 50/60Hz C COIL CODES 0 220 380 440 C5-000 & C5-200 Coil Pair TZ734 (22.8.30-0) TZ747 (22.8.30-3) TZ779 (22.8.30-6) TZ780 (22.8.30-8) Feeder Group TZS734 (22.8.204-0) TZS747 (22.8.204-3) TZS779 (22.8.204-6) TZS780 (22.8.204-8) 480 TZ78 TZS78 Price 660 3230 DC Coil Pairs & Feeder Groups (C5-000 & C5-200) ➋➌ Voltage Range 0 Volts DC 220 Volts DC 440 Volts DC DC COIL CODES C5-000 & C5-200 Coil Pair Feeder Group 0D Refer to factory Refer to factory 220D Refer to factory Refer to factory 480D Refer to factory Refer to factory Price Refer to factory Refer to factory C5 Feeder Group - front view (typical) ➊ Other voltages available. Please contact factory. ➋ C5-550, 700 and 860 contactors are equipped with coils that operate with both C and DC control voltages. For DC coil operation, select C Coil Code for desired DC voltage. C5-000 and 200 contactors operate with C control voltage input that is rectified for DC coil operation. See page 67. Consult factory for DC control voltage input. C5 Coil Pair (typical) C5 Feeder Group - rear view (typical) Discount Schedule B6 6

DISCONTINUED Renewal Parts C5 Contactors C5 Contactors Main Contact - ( Pole Per Set) Main Contacts (pole) (typical) For use with... C5-550 C5-700 C5-860 C5-000 C5-200 Catalog Number C5-CP550 (22.807.202-0) C5-CP700 (22.808.202-0) C5-CP860 (22.809.202-0) C5-CP000 (22.80.202-0) C5-CP200 (22.8.202-0) Price per pole 305 459 608 767 98 rc Chutes rc Chutes (typical) 3-pole ( per contactor) For use with... Catalog Number Price C5-550 C5-700/ C5-860 C5-C550 (22.807.20-0) C5-C860 (22.809.20-0) 890 440 C5-000/ C5-200 C5-C200 (22.8.20-0) 985 -pole (3 per contactor) 62 Discount Schedule B6

DISCONTINUED Technical Information C5 Contactors Technical Information C5-550 C5-700 ➊ C5-860 C5-000 C5-200 Rated Insulation Voltage U i to IEC947- [V] 690 690 690 690 690 UL/CS [V] 600 600 600 600 600 Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 8 8 8 8 8 C5-000 / 200 [kv] 2.5 2.5 2.5 2.5 2.5 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 220/230, 240, 380/400,45,500,660/690 (000V - C5-550 to 860) DC [V] 24, 48, 0, 220, 440V Operating Frequency for C Loads [Hz] 50/60Hz 80/hr. for 0.25s start time - 42/hr. for s start time C5 Contactors Switching Motor Loads Standard IEC Ratings C-2, C-3 230/240V [] 550 700 860 000 200 DOL & Reversing 400/45V [] 550 700 860 000 200 50Hz/60 C 500V [] 550 700 860 000 200 690V [] 500 630 700 860 000 230V [kw] 79 228 280 326 39 240V [kw] 87 238 293 340 408 400V [kw] 32 44 509 592 70 45V [kw] 324 430 528 628 737 500V [kw] 407 58 636 756 888 690V [kw] 50 657 730 897 043 UL/CS 200V [] 44 552 692 ~ 85 DOL & Reversing 230V [] 360 602 722 ~ 30 60Hz 460 V [] 44 590 708 ~ 062 3 575 V [] 336 472 576 ~ 864 200 V [HP] 50 200 250 ~ 450 230 V [HP] 50 250 300 ~ 450 460 V [HP] 350 500 600 ~ 900 575 V [HP] 350 500 600 ~ 900 C4-200,000 Op. Cycles 230/240V [] 40 80 20 260 300 50Hz 400/45V [] 40 80 20 260 300 230V [kw] 45 57 67 83 97 240V [kw] 47 60 70 87 0 400V [kw] 78 0 8 46 70 45V [kw] 8 05 22 5 76 C4-200,000 Op. Cycles (25,000) 230/240V [] 360 430 520 (630) (700) Squirrel-cage motors with reversing 400/45V ➊ [] 350 420 520 (630) (700) and jogging 230V [kw] 6 39 70 (205) (228) 240V [kw] 20 5 77 (24) (245) 400V [kw] 98 238 295 (357) (44) 45V [kw] 206 247 300 (359) (424) ➊ t rated voltage (45V) and rated current: Life span 25%. 63

DISCONTINUED Technical Information C5 Contactors C5 Contactors Electrical Data C5-550 C5-700 C5-860 C5-000 C5-200 Switching Motor Loads (continued) Wye-Delta (Star Delta) 230V [] 953 22 490 732 2078 50 Hz 240V [] 953 22 490 732 2078 400V [] 953 22 490 732 2078 45V [] 953 22 490 732 2078 500V [] 953 22 490 732 2078 690V [] 83 09 95 490 732 230V [kw] 30 395 485 565 677 240V [kw] 324 42 507 589 707 400V [kw] 540 77 882 025 250 45V [kw] 56 745 95 088 278 500V [kw] 705 897 02 309 538 690V [kw] 883 38 247 554 2078 60 Hz 230V [HP] 250 400 500 650 750 460V [HP] 600 800 000 300 500 575V [HP] 600 800 000 500 500 C- Load, 3 Switching I th [] 760 000 00 200 350 mbient Temperature 40 C 230V [kw] 303 398 438 478 538 240V [kw] 36 46 457 499 56 400V [kw] 527 693 762 83 935 45V [kw] 546 79 79 863 970 500V [kw] 658 866 953 039 69 690V [kw] 908 95 35 434 63 mbient Temperature 60 C I th [] 605 800 870 960 085 230V [kw] 24 39 347 382 432 240V [kw] 25 333 362 399 45 400V [kw] 49 554 603 665 752 45V [kw] 435 575 625 690 780 500V [kw] 524 693 753 83 940 690V [kw] 723 956 040 47 297 Continuous Current (UL/CS) General Purpose Rating (40 C) [] 520 700 80 ~ 25 Rated Making Capacity 45V [] 5500 7000 8600 0000 2000 C-3 I e 500V [] 5500 7000 8600 0000 2000 690V [] 5500 7000 8600 0000 2000 Rated Breaking Capacity 240V [] 4400 5600 6900 8000 9600 C-3 I e 400V [] 4400 5600 6900 8000 9600 45V [] 4400 5600 6900 8000 9600 500V [] 4400 5600 6900 8000 9600 690V [] 4000 500 5600 6900 8000 Short Circuit Protection of Contactors Without Overload Relay Fuse gg (am) Type Coordination 500V [] (630) 800 000 000 250 (per IEC 60947-4-) 690V [] (630) 800 000 000 000 64

DISCONTINUED Technical Information C5 Contactors Electrical Data C5-550 C5-700 C5-860 C5-000 C5-200 DC Ratings DC- Rating at 60 C Non-inductive or slightly pole 24VDC [] 645 760 930 020 50 inductive loads, resistive furnaces 48VDC [] 645 760 930 020 50 24VDC [] 645 760 930 020 50 48VDC [] 645 760 930 020 50 2 Poles in Series 0VDC [] 480 560 630 800 900 220VDC [] 35 400 450 500 600 24VDC [] 605 800 870 960 085 48VDC [] 605 800 870 960 085 3 Poles in Series 0VDC [] 480 560 630 800 900 220VDC [] 35 400 450 500 600 DC-3 Rating at 60 C Shunt wound motors - 3 Poles in Series 24VDC [] 605 800 870 960 085 Starting, reverse current 48VDC [] 605 800 870 960 085 breaking, reversing, stepping DC-5 Rating at 60 C Series wound motors - 3 Poles in Series 24VDC [] 605 800 870 900 085 Starting, reverse current 48VDC [] 605 800 870 900 085 breaking, reversing, stepping Lighting Loads C5 Contactors Elec.Dischrg.Lamps-C-5a, Open [] 450 570 700 850 000 single compensated Enclosed [] 360 460 550 660 800 Incandescent Lamps - C C-5b, Electrical endurance ~00,000 operations [] 35 440 500 560 630 Switching power transformers C-6a Inrush = nxi e Rated transformer current Inrush 400 VC [] 7,440 9,450,700 3,500 6,200 400 VC [] 248 35 390 450 540 n=30 400 VC [kv] 72 28 270 32 374 500 VC [kv] 25 273 338 390 468 690 VC [kv] 269 339 376 538 645 n=20 400 VC [] 37 472 580 675 80 n=5 400 VC [] 435 630 774 900 080 Rated making Capacity C-3 I e 45V [] 5,500 7,000 8,600 0,000 2,000 500V [] 5,500 7,000 8,600 0,000 2,000 690V [] 5,500 7,000 8,600 0,000 2,000 Rated making Capacity C-3 I e 240V [] 4,400 5,600 6,900 8,000 9,600 400V [] 4,400 5,600 6,900 8,000 9,600 45V [] 4,400 5,600 6,900 8,000 9,600 500V [] 4,400 5,600 6,900 8,000 9,600 690V [] 4,000 5,00 5,600 6,900 8,000 65

DISCONTINUED Technical Information C5 Contactors C5 Contactors Electrical Data C5-550 C5-700 C5-860 C5-000 C5-200 Capacitor Ratings Capacitor Switching - 50Hz Single Capacitor - 40 C 230 V [kvar] 80 220 250 290 330 240 V [kvar] 200 250 300 325 360 400 V [kvar] 320 400 450 500 575 45 V [kvar] 350 430 500 550 630 500 V [kvar] 450 520 600 660 750 690 V [kvar] 580 700 800 875 000 Single Capacitor - 55 C 230 V [kvar] 50 80 220 275 325 240 V [kvar] 70 200 260 300 350 400 V [kvar] 280 330 400 460 550 45 V [kvar] 300 360 450 500 600 500 V [kvar] 360 420 540 600 720 690 V [kvar] 500 580 720 800 950 Capacitor Bank - 40 C 230 V [kvar] 80 220 250 290 330 240 V [kvar] 200 250 300 325 360 400 V [kvar] 320 400 450 500 575 45 V [kvar] 350 430 500 550 430 500 V [kvar] 450 520 600 660 750 690 V [kvar] 580 700 800 875 000 Capacitor Bank - 55 C 230 V [kvar] 50 80 220 275 325 240 V [kvar] 70 200 260 300 350 400 V [kvar] 280 330 400 460 550 45 V [kvar] 300 360 450 500 600 500 V [kvar] 360 420 540 600 720 690 V [kvar] 500 580 720 800 950 Short-Circuit Coordination Short Time Current Withstand Ratings I cw 60 C s [] 5500 7000 8000 0000 2000 4 s [] 5500 7000 8000 0000 2000 0 s [] 4400 5600 6900 8000 9600 5 s [] 3800 5000 6000 7400 8500 60 s [] 2300 2800 3400 4000 4800 240 s [] 300 800 2000 2300 2700 900 s [] 850 50 350 600 900 Off Time Between Operations [Min.] 60 60 60 60 60 Resistance and Watt Loss l e C3 Resistance per power pole [mw] 0. 0. 0.08 0.06 0.05 Watt Loss - 3 power poles [W] 99 47 77 80 26 Coil and 3 power poles C [W] 0 72 202 250 286 (including series resistor) DC [W] 09 69 99 240 276 66

Electrical Data DISCONTINUED Technical Information C5 Contactors C5-550 C5-700 C5-860 C5-000 C5-200 Coil Data Voltage Range C: 50Hz, 60Hz, 50/60 Hz Pickup [xu s] 0.85... 0.85... 0.85... Dropout [xu s] 0.2...0.5 0.20...0.75 0...0.6 DC Pickup [xu s] 0.85... 0.85... 0.85... Dropout [xu s] 0.2...0.5 0.20...0.75 0...0.6 Coil Consumption C: 50Hz, 60Hz, 50/60 Hz Pickup [V] 800...950 350...600 2400 Hold-in [V] 9... 2...25 70 DC Pickup [V] 700...850 350...600 2400 Hold-in [W] 8...0 2...25 70 Operating Times C: 50Hz, 60Hz, 50/60 Hz Pickup [ms] 50...00 50...00 50...00 Normal Dropout [ms] 50...200 50...200 25...50 Delayed Dropout [ms] 500...000 500...000 ~ ccelerated Dropout [ms] 20...50 20...50 ~ DC Pickup [ms] 50...00 50...00 50...00 Normal Dropout [ms] 50...200 50...200 25...50 Delayed Dropout [ms] 500...000 500...000 ~ ccelerated Dropout [ms] 20...50 20...50 ~ Insulation Class Class B to VDE 0660 table 22 C5 Contactors Control and Magnet System for C5-700 C5-860 Contactors Even though the input to the magnet system can either be C or DC, the low pull-in and holding consumption of the magnet system is achieved by DC operating coils supplied by a Feeder Group. The Feeder Group for these contactors also allows delayed, normal or accelerated dropout times, selectable between 20ms and 000ms. Delayed: (500 000ms) Normal: (50 200ms) ccelerated: (20 50ms) s supplied, the contactors are wired for a normal dropout time. To compensate for wide voltage fluctuations or brief supply voltage interruptions, the dropout time can be delayed by wiring changes made to the Feeder Group at installation. C OR DC C ~ / + RT - ~ / - ~ + ~ 2 2 R VDR Normal drop Coil Circuit for C5-550, 700 & 860 C or DC supply Z M2 M C C Control and Magnet System for C5-000 C5-200 Contactors Even though the input to the magnet system is only designed for C voltages, the low pull-in and holding consumption of the magnet system is achieved by DC operating coils supplied by a Feeder Group. The Feeder Group for these contactors is configured for a dropout time of 25 50ms. Dropout times for these contactors are not selectable. Further information regarding circuit possibilities can be obtained from assembly instructions supplied with each device. C (ONLY) ~ RT - ~ C ~ ~ C + C C () 3 4 +2 RC R 22 R R -2 R R C 2 2 Coil Circuit for C5-000 & 200 C supply (only) 02 02 R R 0 0 C: Coil pair R: DC auxiliary relay coil for economy resistor switching R, RC, RR: Economy resistor VDR: Varistor M, M2: Terminals for fast-drop connection Z: Device for dropout operating time variation () For control voltages up to 25V NC contacts -2 & 2-22 are connected in parallel; higher voltages are connected in series RC 67

DISCONTINUED Technical Information C5 Contactors C5 Contactors Mechanical Data C5-550 C5-700 C5-860 C5-000 C5-200 Service Life Mechanical C Control [Mil.] 5 5 5 DC Control [Mil.] 5 5 5 Electrical C-3 (400V) [Mil.] 0.6 0.6 0.6 0.6 0.6 Shipping Weights C - C5 C Control [kg] 3.8 26.4 28.4 50.3 53.4 DC Control [Lbs] 30.4 58. 62.5 0.8 7.6 C - CU5 C Control [kg] 28.5 53.9 57.9 02.3 08.5 DC Control [Lbs] 63.6 20.3 29.2 228.3 242.2 Terminations - Power Type Direct Connection (customer supplied connections) Hexagonal Bolt b max. [mm] 50 60 60 60 60 c max. [mm] 20 20 25 25 25 s max. [mm] 2 x 5 2 x 5 2 x 6 2 x 6 2 x 8 Ø min. [mm] Refer to C5 stab dimensions below Recommended Torque [Nm] 50 60 75 60 60 [Lb-ft] 37 44 55 44 44 C5 Stab Dimensions 68

DISCONTINUED Technical Information C5 Contactors Mechanical Data (continued) C5-550 C5-700 C5-860 C5-000 C5-200 Terminations - Control Description Combination Screw Head: Cross, Slotted, Pozidrive Coils or 2 [mm2] 4 Wires [WG] 25 Control Modules or 2 [mm2] 4 Wires [WG] 25 Torque Requirement [Nm]...2.5 [Lb-in] 8.9...22 Degree of Protection - contactor IPOO (open) per IEC 60529 and DIN 40 050 C5 Contactors Environmental and General Specifications Rated Isolation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 000V 690V UL/CS [V] 600V 600V Impulse Voltage - U imp minute per IEC 60947- [kv] 8kV 2.5kV mbient Temperature Storage -40...+80 C (-3...76 F) Operation at rated current -25...+70 C (-3...58 F) (40 C per UL) ltitude at installed site 2000 meters above sea level per IEC 60947- Operating Frequency for C Loads 50/60 Hz 80/Hr. for 0.25, start time 42/ HR for s start time Resistance to Corrosion / Humidity Damp-alternating climate: cyclic per DIN 50 06 and 40 046 Part 38 IEC 60068 Operating Position Dry heat: IEC 68-2, + 00 C (22 F), relative humidity,50%, 7 days Damp tropical: IEC 68-2, +40 C (04 F), relative humidity 95%, 56 days ➊ See dimensions page Standards IEC/EN 60947, ul508, csa C22.2 No. 4 pprovals culus, CE ➊ Per DIN 50 06 and 40 046, part 38. 69

C5 Contactors uxiliary Contacts DISCONTINUED Technical Information C5 Contactors uxiliary Contact Block uxiliary Contact Blocks Switching, C & DC Loads C5-EF22 C5-EB, C5-EBDC C-I th at 40 C [] 6 6 at 60 C [] 2 2 C-5, switching electromagnetic loads at: [V] 20 230 240 400 45 500 690 20 230 240 400 45 500 690 [] 6 3 3 2 2.5 6 3 3 2 2.5 DC-3, switching DC electromagnets at: [V] 24 48 0 220 24 48 0 220 [] 6 3 0.5 6 3 0.5 Minimum Switching Capacity 0V, 5M Short-Circuit Protection - ggfuse Type 2 Coordination [] 0 6 Terminals Terminal Type Maximum Wire Size per IEC 947-2 x 4 2 x 4 Flexible with Wire- Conductor [mm 2 ]...4 0.5...2.5 End Fernule 2 Conductor [mm 2 ]...4 0.75...2.5 Solid/Stranded- Conductor [mm 2 ].5...6 0.5...2.5 Conductor 2 Conductor [mm 2 ].5...6 0.75...2.5 Recommended Tightening Torque [Nm]...2.5...5 Max. Wire Size per UL/CS [WG] 6...0 8...4 Recommended Tightening Torque [lb-in] 8.9...22 8.9...3.3 Degree of Protection IP2LX per IEC 529 and DIN 40 050 Mechanical Latch C5-M5 C5-M6 C5-M7 Service Life Mechanical [Mil ops.] 0.5 0.5 0.5 Dropout Delay Contactor Latch [ms] 50...70 50...70 50...70 Trip Coil Consumption C [V] 950 600 3500 DC [W] 500 800 3200 OFF-command (min. impulse duration) [ms] 200 200 200 Operation Voltage Minimum 0.5 U n 0.5 U n 0.5 U n Maximum. U n. U n. U n 70

DISCONTINUED Technical Information C5 Contactors uxiliary Contacts For C5-700 & C5-860 contactors Up to two auxiliary contact blocks can be mounted on each contactor. One four-pole auxiliary contact block (C5- EF22) is supplied standard and is installed on the contactor between T and T2. One additional auxiliary contact block can be installed between T2 and T3. Normal Setting (from factory) uxiliary NC Contacts NO Setting range Main Contacts (open) C5 Contactors Each C5-EF22 contains 2 NO and 2 NC adjustable auxiliary contacts. Standard terminal markings are shown below on the left. If an additional contact block is required, different terminal markings (right) are supplied and may be applied by the user. Delayed NO Contact uxiliary NC Contacts NO djusting screw after four turns to the right 53 6 7 83 Main Contacts (open) 54 62 72 84 djustable uxiliary Contacts The instant at which the NO contact closes, in relation to the main contacts, can be adjusted from the front of the C5-EF22 auxiliary contact block by means of an llen wrench. The following diagrams show the adjustments for Normal, Delayed and Overlapping auxiliary contacts. Overlapping NO and NC Contacts uxiliary Contacts Main Contacts (open) NC NO djusting screw after four turns to the left For C5-000 and C5-200 contactors Up to four nonadjustable auxiliary contact blocks can be mounted on each contactor. One C5-EB two pole aux contact and one C5-EBDC two pole aux contact come standard. The C5-EBDC has NC contact (available) and NO Delayed Make (unavailable) which is used for the operation of the coil feeder group. C5-EB NO/NC C5-EBDC NO Delayed Make/ NC 7

DISCONTINUED Technical Information C5 Contactors Life Load Curves Life-Load Curves C5 Contactors C- C-3 Instructions on How to read Life Curves can be found on page 8 NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 72

DISCONTINUED Technical Information C5 Contactors Life Load Curves Life-Load Curves Inching and plugging of squirrel-cage induction motors during starting; Ue=380...460 VC C-4 0 C5-550 C5-700 C5-860 C5-000 C5-200 C-4 C5 Contactors Contact Life (Millions of Operations) 0. 0.0 0.00 0 0 00 000 2000 Rated operational current Ie C-4 [] NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 73

DISCONTINUED Technical Information C5 Contactors Life Load Curves C5 Contactors Life-Load Curves C-3 (90%), C-4 (0%) 0 Mixed operation with squirrel-cage induction motors C-3-90% starting and stopping of running motors; Ue=380...460 VC C-4-0% starting with inching and plugging; Ue=380...460 VC C5-550 C5-700 C5-860 C5-000 C5-200 C-3 90% C-4 0% Contact Life (Millions of Operations) 0. 0.0 0 0 00 000 2000 Contact Life for Mixed Utilization Categories C-3 and C-4 In many applications, the utilization category cannot be defined as either purely C-3 or C-4. In those applications, the electrical life of the contactor can be estimated with the following equation: L mixed = L ac3 / [+P ac4 x (L ac3 /L ac4 -)], where: Rated operational current Ie C-3, C-4 [] L mixed L ac3 L ac4 P ac4 pproximate contact life in operations for a mixed C-3/C-4 utilization category application. pproximate contact life in operations for a pure C-3 utilization category (from the C-3 life-load curve). pproximate contact life in operations for a pure C-4 utilization category (from the C-4 life-load curve). Percentage of C-4 operations NOTE: The life-load curves shown here are based on Sprecher+Schuh tests according to the requirements defined in IEC 947-4-. Since contact life in any given application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. 74

Operating Rate Curves C-3 000 800 600 Starting and stopping of running motors Starting time t = 0.25 s Relative time energized 40% C5-550 C5-700 C5-860 C5-000 C5-200 DISCONTINUED C-3 Technical Information C5 Contactors Operating Rates C5 Contactors 400 Permissible switching frequency (starts per hour) 200 00 80 60 40 20 0 00 200 400 600 000 2000 4000 6000 0000 Rated motor current Ie C-3 [] 75

C5 Contactors DISCONTINUED Series C5 & Series CU5 (Contactors & Reversing Contactors) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. e2 c e øe øf ø d Dimensions C5 Contactors e3 d b b e3 d2 a c Type a b b c c ød d d2 øe øf e e2 e3 C5-550 220 258 228 225 64 9 220 0 3 40 79 - - (8-2/32) (0-5/32) (8-3/32) (8-7/8) (6-7/6) (3/8) (8-2/32) (4-5/8) (7/32) (-9/32) (3-/8) C5-700 C5-860 C5-000 C5-200 280 (-/32) 280 (-/32) 334 (3-5/32) 334 (3-5/32) 307 (2-3/32) 36 (4-7/32) 490 (9-9/32) 490 (9-9/32) 277 (0-29/32) 325 (2-25/32) 434 (7-/6) 434 (7-/6) 29 (-5/32) 29 (-5/32) 345 (3-9/6) 345 (3-9/6) 203 (8) 203 (8) 23 (9/32) 23 (9/32) (7/6) (7/6) 3 (25/64) 3 (25/64) 280 (-/32) 280 (-/32) 380 (4-3/32) 380 (4-3/32) 75 (6-7/8) 75 (6-7/8) 20 (4-23/32) 20 (4-23/32) 3 (7/32) 5 (9/32) 3 (25/64) 3 (25/64) - (7/6) 3 (25/64) 3 (25/64) 50 (-3/32) 50 (-3/32) 60 (2-3/8) 60 (2-3/8) 0 (4) 0 (4) 00 (3-3/32) 00 (3-3/32) - 32 (-7/64) 40 (-9//6) 40 (-9//6) Reversing Contactors & ccessories Contactor with... Dimension [mm] Dimension [inches] - auxiliary contact block a a - reversing contactors with mechanical interlock next to each other C 5-550-/C 5-550 a+42+a a+-23/32+a C 5-700, -860/ C 5-700, -860 a+32+a a+-/4+a C 5-000, -200/ C 5-000, -200 a+46+a a+-3/6+a C 5-550/C, 5-700, -860 a+37+a a+-5/32+a C 5-700, -860/ C 5-000, -200 a+73+a a+2-7/8+a above each other C 5-550-/C 5-550 b+56+b b+2-3/6+b C 5-700, -860/ C 5-700, -860 b+00...200+b b+3-5/6...7-7/8+b C 5-000, -200/ C 5-000, -200 b+230...280+b b+9-/6...-/32+b C 5-550/C, 5-700, -860 b+00...200+b b+3-5/6...7-7/8+b C 5-700, -860/ C 5-000, -200 b+230...280+b b+9-/6...-/32+b four main contacts C 5-550-/C 5-700, -860 a+68 a+2-/6 C 5-000, -200 a+76 a+3 latch C 5-550 b+47 b+-7/8 C 5-700 b+64 b+2-7/32 C 5-860 b+37 b+-5/32 C 5-000, -200 a+30 a+-3/6 Mounting Position 76

DISCONTINUED Dimensions C5 Contactors Notes C5 Contactors 77

CDP2 Contactors Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air conditioning, refrigeration, resistive heating and many other installations where a low cost, high performance contactor is needed. These devices offer flexibility and are designed to meet or exceed electrical and mechanical requirements as defined by definite purpose contactor standards. Popular sizes for most applications The CDP2 series consists of one, two, three and four pole contactors rated to 600V C. Three pole devices range up to 90, while the one and two pole models are rated to 40. Four pole contactors are also available ranging from 25 to 40. Flexibility and convenience make installation easy Standard Features Universal mounting plate 25 & 30 have screw power terminals that will accept ring-tongue terminals 40 and larger have box power terminals Dual quick-connect power terminals on all sizes Dual quick-connect coil terminals on all sizes Double break power contact design with feed-thru wiring Class B (30 C) coil insulation Double E magnet assembly Optional Features SPDT auxiliary contacts optional on 3- and 4-pole contactors (max of two) Optional covers for - and 2-pole contactors Mechanical interlock for 3-pole contactors CDP2 contactors are compact in size and offer three convenient methods of wire connection: quick connect terminals, screws or box lugs. Box lugs are standard on 40 and larger contactors. Other models come standard with combination quick connect terminals and screws that accept hex, slotted or phillips screwdrivers. One Pole Two Pole Two Pole Three Pole Four Pole 30 40 30 40 30 40 50 60 75 90 30 40 78

Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (300 C Insulation System) with wide range of voltages and 50/60 Hz ratings. Includes shading coil that reduces contact chatter. Snap-on uxiliary Contact (optional on 3 and 4 pole contactors) One or two SPDT (shown) available. lso NO and NC with 600V C rating. Industry Standard Mounting Plate Easily accessible mounting holes. Coil Terminals #6-32 screw and one.250 Quick Connect or Dual.250 Quick Connects (will accept two insulated quick connect terminals). Double E Magnet ssembly Provides optimal performance with reduced power consumption Stationary Terminal One piece terminal design with integral dual.250 Quick Connects. Meets NEM standard for spacing without insulated terminals. CDP2 Contactors Base ssembly High arc resistant polyester holds stationary terminals, positions actuator and magnet/coil assembly. Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability ctuator Molded from high arc resistant polyester, holds upper magnet, movable contacts and contact springs position. Quick Selection Guide One and Two Pole Definite Purpose Contactors with C Coil - See page 52 CDP2 ➊ P 30 24 Type Frame Size Poles mp Rating Coil Voltage Definite = 30 & 40 P = pole 30 = 30 amps 24 = 24 volts Purpose 2P = 2 pole 40 = 40 amps 20 = 20 volts 220W = 208-240 volts 277 = 277 volts Three Pole Definite Purpose Contactors with C Coil- See page 53 CDP2 ➊➋ B 3P 30 24 Type Frame Size Poles mp Rating Coil Voltage Definite B = 30 & 40 3P = 3 poles 30 = 30 amps 24 = 24 volts Purpose C = 50 & 60 40 = 40 amps 20 = 20 volts D = 75 & 90 50 = 50 amps 220W = 208-240 volts 60 = 60 amps 277 = 277 volts 75 = 75 amps 480 = 480 volts 90 = 90 amps Four Pole Definite Purpose Contactors with C Coil - See page 54 CDP2 ➊➋ E 4P 25 24 Type Frame Size Poles mp Rating Coil Voltage Definite E = 25...40 4P = 4 poles 25 = 25 amps 24 = 24 volts Purpose 30 = 30 amps 20 = 20 volts 40 = 40 amps 220W = 208-240 volts 277 = 277 volts 480 = 480 volts ➊ Screw power terminals standard on 30. Box lug power terminals standard for 40 and larger. ➋ Box lugs on 30 available with volume special order only. 79

Definite Purpose Contactors & 2 Pole - Series CDP2 CDP2 Contactors One and Two Pole Definite Purpose Contactors with C Coil (Open type only) ➍ Full Load mps Poles Maximum H.P. Locked Rotor mps Resistive mps ➋ Ø 240V ➋ 480V 600V 20V 240V ➋ Catalog Number Price Each 30 ➊ ➏ 50 75 50 40 2 CDP2-P30- ➎ 64.80 50 Std. Pkg. 30 ➊ 2 50 25 00 40 2 3 CDP2-2P30- ➎ 79.90 50 Series CDP2 -pole contactor 40 ➏ 200 50 20 50 2 3 CDP2-P40- ➌ 82.50 50 40 2 200 50 20 50 2 3 CDP2-2P40- ➌ 96.0 50 Series CDP2 2-pole contactor (with optional cover) ccessories ccessory Description For use with... Catalog Number Price Contactor Cover- Prevents foreign particles from entering contactor. Covers current carrying parts. CDP2-P30... CDP2-2P30... CDP2-P-C ➐ CDP2-2P-C 7.79 9.36 C Coil Codes C Coil Code Ordering Instructions 80 Voltage Range 60 Hz 24 24V 20 20V 220W 208-240V 277 277V Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ 25 contactors only available by special order. Contact your Sprecher +Schuh representative. ➋ 240V rating also applies to 277V applications. ➌ Box Power Lugs are supplied as standard. Screw terminals are available on the power connections by special order only in quantity. ➍ and 2 Pole, 25 and 30 contactors supplied without cover. See ccessories for cover options. ➎ Screw Power Terminals are supplied standard on 25 and 30 contactors. Box Lugs available by special order only in quantity. ➏ -Pole (-pole plus) contactors include a shunt for termination and feed-thru of neutral. ➐ 40 mp contactors are supplied with cover as standard. Discount Schedule B8

Three Pole Definite Purpose Contactors with C Coil (Open Type only) Full Load mps Locked Rotor mps Resistive mps ➋ Maximum Horsepower ➋ Ø 3Ø 240V ➋ 480V 600V 20V 200 240V 200V 240V 480V 600V Catalog Number Definite Purpose Contactors Price Each 30 ➊ 80 50 20 40 2 ~ 5 0 0 5 20 CDP2-B3P30- ➍ 02 25 Std. Pkg. 3 Pole Series CDP2 CDP2 Contactors 40 240 200 60 50 3 ~ 7-/2 0 0 20 25 CDP2-B3P40- ➌ 24 25 50 300 250 200 65 3 7-/2 0 5 5 25 25 CDP2-C3P50-238 5 Series CDP2 3-pole contactor 60 360 300 240 75 5 7-/2 0 25 25 30 30 CDP2-C3P60-276 5 75 450 375 300 93 5 0 5 20 25 40 40 CDP2-D3P75-360 90 540 450 360 20 7-/2 5 20 25 30 50 50 CDP2-D3P90-498 uxiliary Contacts for 3 Pole Contactors uxiliary Description Circuit Diagram Catalog Number Price Two pole uxiliary Contact Block (-NO / -NC) - Side mount with quick connect stabs for 25...40, 3 pole contactors NC CDP2-BE- ➏ 39.00 for 50...90, 3 pole contactors CDP2-CD- ➎ 40.32 NO One pole uxiliary Contact Block (SPDT) - Side mount with quick connect stabs for 25...40, 3 or 4 pole contactors COM NC CDP2-BE-SPDT ➎ 34.42 NO C Coil Codes C Coil Code Voltage Range 60 Hz 24 24V 20 20V 220W 208-240V 277 277V 480 480V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ 25 contactors available by special order. Contact your Sprecher + Schuh representative. ➋ 240V rating also applies to 277V applications. ➌ Box lugs are supplied as standard. Screw terminals are available on the power connections by special order only in quantity. ➍ Screw power terminals are supplied standard on 25 and 30 contactors. Box Lugs available by special order only in quantity. ➎ Meets NEM Standard B600. See page 7 for technical details. ➏ Meets NEM Standard B600 EXCEPT has 0 continuous current rating. Discount Schedule B8 8

CDP2 Contactors Four Pole Definite Purpose Contactors With C Coil (Open Type only) Full Load mps Locked Rotor mps 240V ➋ 480V 600V Resistive mps ➋ Maximum Horsepower ➋ Ø 3Ø 20V 240V 200V 240V 480V Catalog Number Price Each 30 ➊ 80 50 20 40 2 5 0 0 5 CDP2-E4P30-Q ➍ 8 20 Std. Pkg. Definite Purpose Contactors 4 Pole Series - CDP2 40 240 200 60 50 3 7-/2 0 0 20 CDP2-E4P40-Q ➌ 37 20 Series CDP2 4-pole contactor uxiliary Contacts for 4 Pole Contactors uxiliary Description Circuit Diagram Catalog Number Price Two pole uxiliary Contact Block (-NO / -NC) - Side mount with quick connect stabs for all 4 pole contactors NC NO CDP2-BE- 2.30 One pole uxiliary Contact Block (SPDT) - Side mount with quick connect stabs for all 4 pole contactors COM NC NO CDP2-BE-SPDT 9.50.C. Coil Codes C Coil Code Voltage Range 60 Hz 24 24V 20 20V 220W 208-240V 277 277V 480 480V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ 25 contactors available by special order. Contact your Sprecher + Schuh representative. ➋ 240V rating also apples to 277V applications. ➌ Box Power Lugs are supplied as standard. Screw terminals are available on the power connections by special order only in quantity. ➍ Screw per terminals are supplied standard on 25 and 30 contactors. Box Lugs available by special order only in quantity. 82 Discount Schedule B8

Definite Purpose Contactors Lighting Rated Contactors - Series CDP2 Definite Purpose Lighting Contactors with C Coil (Open Type only) Tungsten Rating (mps) Ballast Rating (mps) Number of Poles Standard uxiliary Contacts NO Open Type Electrically Held Catalog Number Price 30 40 0 0 CDP2-P30-64.80 NC Series CDP2 -pole contactor CDP2 Contactors 40 40 0 0 CDP2-P40-82.50 30 40 2 0 0 CDP2-2P30-79.90 40 40 2 0 0 CDP2-2P40-96.0 30 40 3 0 0 CDP2-B3P30-02 40 40 3 0 0 CDP2-B3P40-24 30 40 4 0 0 CDP2-E4P30-8 40 40 4 0 0 CDP2-E4P40-37 Series CDP2 3-pole contactor Description Sprecher + Schuh Definite Purpose contactors can be used to control a mixture of lighting loads. These contactors are well suited to handle the high inrush currents typical of this application as well as other non-motor (resistive) loads. Lamps can basically be divided into three categories: Tungsten Filament Lamps - General purpose incandescent - Special purpose incandescent - Infrared - Sodium Iodine Discharge Lamps (with Ballast) - Fluorescent lamps - Mercury vapor - High/low pressure sodium - Quartz - Halogen metal-vapor Mixed Light Lamps In pplication... The tungsten filaments of incandescent lamps have a very low ohmic resistance when cold. s a result, the closing current is very high but also very short. The closing current of discharge lamps (lighting with ballast) is highly inductive (due to seriesconnected transformers or chokes), and its duration depends on the lamp type. Electrically held contactors Electrically held contactors are available for use where the control signal is activated by a timer or other maintained electrical signal. The coil is energized as long as the contactor is closed. This design is well suited for applications where lights are operated frequently or where the control panel is in a remote location. C Coil Codes C Coil Code Voltage Range 60 Hz 24 24V 20 20V 220W 208-240V 277 277V 480 480V Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page Discount Schedule B8 83

ccessories/technical Information Series CDP2 Definite Purpose Contactors CDP2 Contactors ccessories uxiliary Description For use with... Catalog Number Price DIN-rail daptor - ttaches to the universal mounting plate of -, 2-, 3- and 4-pole contactors 25...40 mps. CDP2-P B3P CDP2-E4P CDP2-DR 2.30 Mechanical Interlock - Can be combined with electrical interlocks on 3-pole and 4-pole contactors as required. CDP2-B3P CDP2-E4P CDP2-MK 9.50 84 Discount Schedule B8