XLB Series Power Supply Application Notes

Similar documents
2. Description of Standard NUV Lightsource (350nm-450nm) 3 3. Description of Deep UV (220nm-280nm) and Mid UV (280nm-310nm) Lightsource Systems 3

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

4707 DEY ROAD LIVERPOOL, NY PHONE: (315) FAX: (315) M.S. KENNEDY CORPORATION MSK Web Site:

A6Z OPERATING MANUAL

Welcome to PTI--Photon Technology International--Optical Building Blocks!

A3Z OPERATING MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

A1P OPERATING MANUAL

ELLIPTICAL REFLECTORS

Phoenix Inverter

XENON POWER SUPPLY for 10 kw Britelight Lamphead

STATIC DAYLIGHT PAR 575 VF

Luzchem Solar Simulator SolSim2 Updated September 2018

SST-ST75F-ESS The essential silver standard

CV - 6SL INSTRUCTION MANUAL 6000W POWER SUPPLY

Features. Figure 1. EFIL-28 Connection Diagram

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

FLUORESCENT INDUCTION

XLR Energy Storage Module

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Germipak UV Cell Lamps

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

G213V STEP MOTOR DRIVE REV 7: March 25, 2011

SSX-180ST. SolarMaxx 180 Illuminator Service Manual

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

96W Ultraviolet LED Light Bar - Submersible Underwater Light 'L X 200'W Spot VDC

EPS/ELA-Series User Manual EPS/ELA 250W

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

10000AR X2 INSTALLATION MANUAL

Professional Wireless Products

Energy efficient low voltage dichroic mirror halogen reflector lamps

EMERGENCY VEHICLE BATTERY MANAGER PS2024

High Frequency SineWave Guardian TM

G203V / G213V MANUAL STEP MOTOR DRIVE

CeraLux Lamp Module Assembly Instructions

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

SPECIFICATION FSP350-60APN(85) Bronze. (Erp2013) DATE:MAY, 14, 2013 表單編號 :7000P Page1

PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM

OPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

VFD Best Practices: Getting the Most from Your VFD Investment

PAF500F24 SERIES Instruction Manual

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

XLM 62V Energy Storage Module

CeraLux Lamp Module Assembly Instructions

SCR Power Controllers

55 Watt K Triple Series DC/DC Converters

ELECTRICAL INTERFACE TO DC BRUSHLESS MOTORS SUPPLIED IN TECNADYNE THRUSTERS, LINEAR & ROTARY ACTUATORS & HPU s

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Maximum output power with circulator Wo 6 kw. Maximum output power without circulator Wo 5 kw

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Preparing the Site. Information About the Site Requirements CHAPTER

3. Design Requirements

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

4000 SYSTEM OPERATING MANUAL

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

300 Watt LED High Bay Light Fixture VAC W Metal Halide Equivalent - 29,580 Lumens

Instruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL

LS-1 Series Tungsten Halogen Light Sources

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

MaxPak Plus Analog DC V S Drive

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

MALSR APPROACH LIGHTING. Medium-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS AND STEADY BURNING LIGHTS

Applications Manual of DPG serises

AIR COOLED RECTIFIER SPECIFICATION S-50-A

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

BL7000 SYSTEM OPERATING MANUAL

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Features. Description. Table of Contents

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Switching DC Power Supply

Not for New Design 10 WATT WD DUAL LOW INPUT SERIES DC/DC CONVERTERS. Features

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

Contents. DX Ignition Page 2

Lecture 2. Power semiconductor devices (Power switches)

SSX-300ST SolarMaxx 300 Illuminator

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

User s Manual. For DM542T. Full Digital Stepper Drive

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RP Instruction Manual

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

PIN DESCRIPTION. Enable (Input) IN GND OUT FLG ADJ LM39300T-X.X LM39300-X.X

Installation & User Instructions

AUTO CHARGE 1200 PUMP PLUS

1.5KW DC-DC Converter Specification

User s Manual-M752. Stepper Motor Driver. Version All Rights Reserved. Attention: Please read this manual carefully before using the driver!

(typ.) (Range) Load

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

XENON POWER SUPPLY 4000 Watt Gladiator IV

Open Frame Power Supplies

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Transcription:

XLB Series Power Supply Application Notes Introduction The XLB series short arc lamp power supplies are designed to ignite and properly power Xenon short arc lamps ranging in power from 100 watts to over 6000 watts. These power supplies are easy to operate and will perform reliably for many years with virtually no maintenance if a few simple steps are followed. This document is a guide to proper installation and operation of these power supplies and should be used to assess the viability of the power supply and igniter in both new and upgrade applications. Basic Operation (Refer to figure 1, page 2) AC Input Power Circuitry AC input power is processed through a line filter to reduce the conducted EMI to an acceptable level. The XLB-1000/1500 line filter has minimum capacitance to ground to minimize leakage currents. Power Factor Correction Boost Inverter The rectified input power is next applied to a power factor boost inverter. This inverter boosts the input voltage to 400VDC. In the process of boosting the rectified input voltage, the input AC current is adjusted so that it is always in phase with the input AC voltage. Without this power factor correction circuit, the AC input current would be delivered to the power supply in high amplitude, narrow spikes containing high harmonic content. With power factor correction, the non- 50/60 Hz harmonics are reduced to near zero. Since only the fundamental frequency is now used to deliver power, the efficiency of the power supply is improved considerably. One problem with standard input power factor correction circuits is that a high frequency switching circuit is placed across the line in the input side of the traditional filter capacitor. This circuit results in substantial switching noise conducted to the line. Lumina Power employs a proprietary soft-switching boost inverter which produces minimum switching noise, reduces switching losses, and results in a smaller heat sink associated with the power factor circuit. Zero Voltage Switching (ZVS) Inverter The ZVS inverter and the output transformer are used to step the 400VDC bus down to the appropriate output value. The ZVS inverter is the most modern high frequency/low loss/low noise topology utilized in power electronics today. Instead of running the inverter in a traditional PWM mode, the inverter is run in a phase shift mode. With the appropriate output inductor and capacitance across each switching device, in this case MOSFETS, there are virtually no switching losses in the inverter. The only losses in the devices are I 2 R losses associated with the Drain/Source resistance of the 1

MOSFETS. Therefore, the ZVS inverter also contributes to reduced losses, reduced EMI noise and a reduction in overall system heat sink requirements. Output Circuit The output circuit is a single stage RC filter designed to minimize output ripple and noise. Control Circuit The control circuit handles all the responsibilities associated with safe operation of the Xenon lamp. Reliable lamp ignition as well as tight current regulation, overvoltage and over power protection are controlled and monitored in the control circuit. Auxiliary Power All internal power supply requirements, as well as the external +15V power supply, are derived from the power factor control boost inductor. The +15V auxiliary voltage is regulated by a standard linear regulator. Lamp Igniter Module The igniter module provides the 40kV pulse required to break down the Xenon gas and facilitate ignition. In standard configurations, the pulse is applied through the positive output to the lamp anode. Power to the module is provided by the main power supply chassis. Internal circuitry in the igniter module senses the presence of the high voltage arc and briefly disables operation in the main power supply chassis in order to minimize damage from high voltage noise. Figure 1 Block Diagram 2

Xenon Lamps Other than lasers, short arc lamps are the brightest manufactured sources of DC radiation. A large portion of their output is in the UV-VIS, which makes them useful for UV spectroscopy, UV photochemistry, solar simulation and other high intensity light applications. Xenon short arc lamps have a correlated color temperature close to that of the sun, ~5800 K. The arc region between the anode and the cathode is so small that for many purposes, these lamps are effectively point sources. These small, bright sources can produce high intensity collimated beams using condensing lens assemblies or be re-imaged onto fiber optic bundles. Power levels of 50 to 5000 Watts are typical but Xenon arc lamps can be built to power levels of 30kW. Arc Lamp Basics Fig. 2 shows the construction of typical arc lamps. The anode and the cathode are sealed in a clear quartz envelope. Quartz is used for mechanical and thermal durability. The type of quartz used depends on the desired ultraviolet output. Some lamps use high quality UV grade quartz to transmit output to below 200 nm. Others use doped quartz, which absorbs short wavelengths to minimize ozone generation and are referred to as ozone free lamps. The quartz bulb is carefully shaped to withstand the thermal gradients and shock inherent in running these lamps. The bulb has a small sealed-off tip used to evacuate air and fill with Xenon during construction. Construction of Arc Lamps. Anode and Cathode: The anode and cathode are made of tungsten. The tungsten used in the cathode is doped with materials such as thorium dioxide to enhance electron emission. The cathode is small and pointed to ensure that the tip reaches a high temperature for efficient electron emission. The anode is more massive to withstand the electron bombardment and efficiently dissipate the heat produced. The anodecathode gap can be from 0.25 mm to several mm, depending on the lamp power rating. Gas Fill: Lamps are filled with Xenon at several atmospheres pressure. When the lamps run, the internal pressure increases to 12 to 75 bar, depending on the lamp type. The high pressures demand special care in the handling and operation of these lamps. Typical Xenon Arc Lamp Quartz Bulb Xenon Gas Fill +ve Terminal Cathode Terminals: The two metal terminals at the ends of the lamp are for the electrical connections and mechanical support of the lamp. The terminals are connected to the electrodes by molybdenum foil strips inside the glass stem, or, for the higher current lamps, by tungsten rods. Figure 2 Optional Starter Wire Anode Molybdenum Conductor - ve Terminal 3

Cermax Lamps Cermax lamps are compact ceramic xenon short-arc lamps. Combining an internal reflector, ceramic body and seal construction, Cermax lamps are a compact alternative to conventional quartz xenon lamps. Utilizing an integrated parabolic or ellipsoidal reflector, Cermax lamps produce a high intensity, collimated or focused output of light. Due to the xenon lamps broad color spectrum, the lamp is filtered to emit either visible, UV or IR light depending on application or usage. Standard Cermax lamps have operating power ranges from 75 to 2500 watts. Lamp Stability Arc instability or arc wander as it is called is a common phenomenon in arc lamps. These spacial variations in the arc are usually the result of convection currents in the lamp and/or arc migration on the electrodes. Over the years lamp manufacturers have worked to reduce the effect by improving the design and materials used in the electrodes. There has also been a lot of research into magnetic stabilization of the arc. These methods have improved the stability of the lamps but not completely eliminated the problem. In most cases the small variation in light output can be tolerated but for precise applications your lamp manufacturer should be able to assist you in selecting the best lamp for your program. Older power supply designs with high amounts of AC ripple can also cause instability in the lamp s light output. These low frequency (<120Hz) variations could be very noticeable and usually require additional filtering of the power supply s output to stabilize the light. All XLB power supplies use advanced switch-mode designs that produce very small amounts (<0.5%) of ripple in the output at frequencies above 60kHz that have no effect on the stability of the lamp. Power Supply Installation The XLB series power supplies are designed to accept a wide range of input voltages allowing these supplies to be installed anywhere in the world. The XLB-650 & 1000 accept 100 to 240VAC ±10% while the XLB-1500, 2500 & 3000 require 200 to 240VAC ±10%. The XLB-5000 requires 3 phase current and can be set for 200 to 240VAC or 380 to 440VAC ±10%. Proper input wire size should be used for proper operation and safety. For input cables that are under 6 feet long use the following wire sizes: Model XLB-650 (120VAC) XLB-1000 (120VAC) XLB-1500 XLB-2500 XLB-3000 XLB-5000 Wire Size 16 gauge 14 gauge 14 gauge 12 gauge 12 gauge 10 gauge Any input AC voltage must be considered extremely dangerous. care must be taken when connecting AC input power to the unit. Note: These wire sizes are for reference only. Please consult your local electrical codes for wire sizes. 4

Single phase XLB units are fused on both input lines. It does not matter which of the two AC inputs are designated Line or Neutral. Mounting and Cooling All XLB series power supplies require adequate airflow for proper cooling. These power supplies can be mounted horizontally using the mounting tabs on each side of the supply or vertically with the airflow exhaust aimed upward. It is essential that exhausted hot air from the power supply is directed out of the enclosure and is not allowed to recirculate back through the power supply. Output Connections Connecting the output of the power supply requires the use of the proper size wires equipped with terminals that are crimped and soldered to reduce heating at these points. These wires will be required to carry high current and should be as short as possible. The following table offers guidelines on proper wire sizes for the output currents of the various models. Output Wire Size Chart (Assuming 3 feet from power supply to the igniter) Output Current Wire Size 20 to 30 amps 12 gauge 30 to 50 amps 10 gauge 50 to 70 amps 8 gauge 70 to 100 amps 6 gauge 100 to 150 amps 4 gauge 150 to 200 amps 2 gauge Terminals must be crimped and soldered to reduce heating at these points. Excessive heating of the terminations can damage the power supply and/or the igniter and is not covered under warranty. The output terminals of the XLB power supplies are fitted with the following connectors or screw sizes. Model XLB-650 XLB-1000/1500 XLB-2500 XLB-3000 XLB-5000 Connector Molex connector 8-32 Screws 1/4-20 Screws 1/4-20 Screws 1/4-20 Screws The XLB-650 is equipped with a Molex # 42818-0212 connector. Mate and 24 cable supplied. All other models require customer supplied cables. 5

Control Interface All XLB power supplies share a common 15 pin Analog/TTL interface. For more detailed interface information please refer to the XLB Owners Manual. Standard 15 Pin Interface (15 pin D-Sub, Female) Pin # Pin Name Functional Voltage Level Description 1 Lamp On/Off (input) (Note: 1) High = RUN = +5V to +15V Low = OFF = 0V The Lamp On/Off function is the control function which turns the lamp on and off. When the lamp is turned on, a trigger and boost sequence will ignite the lamp and deliver current as programmed via Iprogram, Pin 7. 3 Interlock (Input) Open = OFF Connect to GND = RUN The Interlock function can be connected to external interlock switches such as door or overtemp switches. 4,9, 15 GND Interface Return 5 Vout Monitor (output) 0-10V = 0-Voutmax The output voltage of the supply can be monitored by Vout Monitor. Note: See selection chart on page 2 for maximum output voltage setting per model. 6 Iout Monitor (output) 0-10V = 0-Ioutmax The output current of the supply can be monitored by Iout Monitor. 7 Iprogram (input) 0-10V = 0-Ioutmax The power supply output current is set by applying a 0-10V analog signal to Iprogram(+). 8 Lamp Status High = lamp off = 15V Low = lamp on = 0V The status of the lamp can be monitored using this pin 13,14 +15V (output) Auxiliary 200mA Pin 2 and 10: no connection 6

Igniter Module The igniter module provides the high voltage pulse that creates a high potential from the cathode to the anode of the lamp forcing an arc to form between these electrodes. Once the electrical path is established the impedance of the lamp drops allowing current to flow. The XLB igniter operates automatically when the power supply is enabled (see interface information pg. 6). The Igniter is connected between the power supply and the lamp and is charged from the boost voltage generated by the power supply when enabled. Figure 3 is the wiring diagram for the power supply/igniter combination: _ Lamp + AC input Trigger feedback wire Interface + _ GND + Power Supply Output Igniter Figure 3 (positive Ignition) The Igniter output is a high voltage pulse of about 1us. that will rise in voltage until the lamp ignites. The ignition point of the many different models offered by the lamp manufacturers varies widely and can range from 15kV to as high as 40kV. During the life of the lamp, the ignition voltage continues to rise until at the end of the lamp s usable life the electrodes have deteriorated to a point where the lamp will not ignite. If the lamp fails to ignite, the Igniter has the capability to output as much as 45kV before shutting down so care needs to be taken to wire the lamp correctly. Here are some recommended wiring and installation precautions to ensure proper lamp ignition. 1. The Igniter should be mounted as close to the lamp housing as possible. The distance from the power supply to the igniter is less critical and can be determined by the max current and practical wire size. Refer to wire size charts page 5 High Voltage does not run through the wire from the power supply to the igniter so isolating these wires for high voltage is not necessary. 2. The maximum distance of wire between the igniter and the lamp should be as short as possible with a recommended maximum length of no more than 30cm (15cm is preferred). 3. The combination of high starting voltage and high running current in the wires between the igniter and the lamp make the layout very critical. Typically available high voltage wire with a 7

high enough dielectric rating to handle 45kV pulses are not offered in wire sizes suitable for the high operating currents required of short-arc lamps. Most connections between the igniter and the lamp are made using insulated wire with a breakdown voltage of 600 to 1000 volts. This wire when sized properly will easily handle the current but it needs to be isolated from grounded surfaces and any wires that may provide a path to ground. Keep this wire at least 25mm away from grounded surfaces and do not bundle this wire with other wires. Use plastic standoffs or flexible conduit if necessary. If your lamp does not start the first time you should thoroughly examine your igniter to lamp connections and make any necessary changes to enable the full energy of the igniter to get to the lamp. 4. Covering the igniter is not recommended. If necessary due to safety concerns the cover should not be metal. To avoid reducing the efficiency of the igniter any cover should be kept at least 25mm from the Igniter s inductor on all sides. See also Cooling the Igniter below. Trigger Wire The power supply/igniter ships with a 60cm twisted pair wire called the trigger wire. This wire must be connected between the power supply and the igniter for proper operation. This feedback wire signals the power supply to temporarily shutdown for about 50us while the ignition pulse is discharged into the lamp. During this shutdown period any noise from the ignition pulse cannot return through the power supply potentially damaging the supply and other equipment near the power supply. This is an exclusive feature of the Lumina Power XLB/MLB family of power supplies Cooling the igniter The igniter used with all of the XLB power supplies is a series igniter. Once the lamp is lit the full output current from the power supply to the lamp travels through the large red inductor of the igniter. Proper mounting and cooling of the igniter is important to ensure reliable operation. Overheated Igniters are not covered under warranty. The chart below offers some suggested cooling methods as a guide in mounting the igniter. In all cases the installation of the igniter in the exhaust of the lamp cooling system is not recommended and will damage the igniter. The maximum temperature of the inductor should not exceed 85 C Model Igniter cooling (ambient air 30 C) XLB-650 11001269 No fan required if open to air with no restrictions XLB-1000 11001269 No fan required if open to air with no restrictions XLB-1500 11001269 10cfm across inductor XLB-2500 11001268 20cfm across inductor XLB-3000 11001268 20cfm across inductor XLB-5000 11001305 Intregal fan mounted on base, maintain 1 clearance for fan intake. 8

For additional assistance with these products please contact Lumina Power customer service during normal business hours Mon. through Fri., 8:00am to 5:00 PM EST (GMT-5), 978-241-8260 or sales@luminapower.com. Notes: 9