Operating instructions. METTLER TOLEDO MultiRange Table and stand scales. KA15s/KA32s KB60/KCC150/KCC300.

Similar documents
4.1 Cleaning the exterior. 4.2 Cleaning the interior

Operating instructions. METTLER TOLEDO MultiRange Floor scales/pit scales

2. Putting into operation. 3. Equipotential bonding. 4. Technical data DRF/DSF (stainless steel)

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PUA574 / PUA579(x)

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA579(x)lift / PFA779lift.

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales For hazardous areas

Guide for installers. METTLER TOLEDO MultiRange Explosionsproof weighing system with the ID3sTx weighing terminal.

PFA579lift/PFA579xlift Efficient Cleaning 100% Stainless Steel Robust Industrial Design Ex Designs. Setting a New Standard in Challenging Environments

Operating instructions Accu Jet

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Rotary feed-through DDF-S/-KS

Floor balances. PFA574 PFA575 PFA579 rugged reliable multi-faceted flexible. Multi-purpose balances for use in industry

Declaration of Conformity as per Directive 97/23/EC

Kontrols & Industrial Weighing. IF flat-bed scales for use in the chemical, pharmaceutical and food industries.

Quick Guide. brite Advanced Retail scale

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

AutoLabeler. User s Guide A (3/02).01

KERN KFP_V20 Version /2012 GB

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres

IF flat-bed scales for use in the chemical, pharmaceutical and food industries.

Type 6213 EV, 6281 EV

Explosion protected terminal boxes type, GHG 72.

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Installation manual wall-mounted distributor

Ex m Solenoid Operator Type 0519

SensoLyt 700 SensoLyt 700 SW

Installation manual portable distributors

Operating Instructions

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

System 6000 Electropneumatic Converters for DC ranges I/P Converter Type 6102 Type 5288

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating Instructions for Elevator Buffers type LP

BSW , -204 Inductive Rotary Cam Switches. User's Guide. Rotary Cam Switches BSW BSW

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

STAND FOOT - STAND TUBE

Layher Ladders Instructions for Assembly and Use. Quality management certified according to DIN EN ISO 9001:2000 by TÜV-CERT.

General Operating Manual

Rittal CM Compact System Enclosures

GAN Electronic 750W/1000W DE US

Solenoid Valve Island Type 3965

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

! C A U T I O N! Damages on the machine possible.

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

STAND MODEL FOR MACH M2

Differential pressure transmitter PASCAL Ci4 Delta P

Assembly and Operating Instructions

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Centrifugal fan with highly efficient EC drive motor

Flash Point Process Analyzer

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS FOR ROTEX 3/2 DIRECT ACTING, UNIVERSAL TYPENUAL RESET SOLENOID VALVE MODEL M3007

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

Swing Piston Compressors and Vacuum Pumps

3 Axles and brakes. 3.1 Function and construction of the axles Construction Function

Mini slide EGSC-BS-KF. Operating instructions b [ ]

BS 2/K Transverse Conveyor

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Mounting instructions Directions for use MAKROLUX. Halogen-spot lamp for consulting room and hospital

Mounting and Operating Instructions EB 5868/5869 EN

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

FiltoSkim Operating instructions Notice d emploi Instrucciones de uso

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Installation information. METTLER TOLEDO IND425 / IND435 / IND445 / IND465 terminals

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

HEAVY DUTY TROLLEY JACK. Operation Manual

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Volkswagen New Beetle Body - Exterior 64 Glass, Window regulators (Page GR-64)

Rotary feed-through DDF 2

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

X-Series System Manual Part 3: Weighframes, Sizes 2 and 3

ADN-W L 10. Battery Charger. Instruction manual

Porte 150 Users Manual Swing Gate Opener 24V DC

97100 NAMUR. Technical data

Differential pressure gauge Model , copper alloy Model , stainless steel version

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Spindle axis ELGC-BS-KF. Operating instructions [ ]

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

The filling level sensors are designed in accordance to the following standards

ACROBAT SWING STAND MODEL

Instruction manual. EK6 Earthing switch 36/40.5 kv

OPERATING INSTRUCTIONS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Transcription:

Operating instructions METTLER TOLEDO MultiRange Table and stand scales KA15s/KA32s KB60/KCC150/KCC300 www.mt.com/support

2

1 General information The weighing platform is part of a modular system. The associated components, such as terminals, application pacs and the extensive range of accessories, allow you to assemble a weighing system ideally tailored to the needs of your operation. 2 Safety precautions The explosion-protected weighing platform is approved for operation in Zone 2 (gases) and Zone 22 (dusts) hazardous areas. There is an increased danger of injuries and damage when using the weighing platform in hazardous areas! Exercise particular care when using in such areas. The rules for behaviour are based on the concept of "Safe Distribution" established by METTLER TOLEDO. Explosion-protected weighing platforms may be used in hazardous areas of Zones 2 and 22 only in conjunction with weighing terminals that have the appropriate approval and interface specification. The connection cable may not be separated from the weighing terminal while it is energised. Selecting installation location The foundation must be capable of safely support the weight of the weighing platform at its support points when it carries the maximum load. At the same time, it should be so stable that no vibrations occur during weighing operations. These requirements also apply when the weighing platform is integrated in conveying systems and the like. Ensure that vibrations due to machines near the installation site are kept to a minimum. Ambient conditions Use powder-coated/enamelled weighing platforms only in a dry environment. In a damp environment, in wet operation or when working with chemicals: use stainlesssteel weighing platforms. 3

3 Equipotential bonding The equipotential bonding must be installed by a professional electrician when using the weighing platform in Zones 2 and 22. METTLER TOLEDO Service only has a monitoring and consulting function here. Connect equipotential bonding (PA) of all devices (weighing platform and service terminal) in accordance with the country-specific regulations and standards. In the process, make sure that all device housings are connected to the same potential via the PA terminals. Equipotential bonding with KA... (1) Serrated lock washer A 4.3 DIN 6798 (2) Hexagonal lock nut M4 DIN 934 (3) Washer 4.3 DIN 125 (4) Base frame (5) Equipotential bonding clamp Mounting materials are enclosed with the ID7xx, IND690xx or IND4..xx weighing terminal. Equipotential bonding with KB..., KCC... (1) Frame body (2) Fillister head screw M5x12 DIN 912 (3) Washer 5.3 DIN 125 (4) Serrated lock washer 5.3 DIN 6798 (5) Washer 5.3 DIN 125 (6) Hexagonal lock nut M5 DIN 934 (7) Hexagonal lock nut M4 DIN 934 (8) Washer 4.3 DIN 125 (9) Serrated lock washer A 4.3 DIN 6798 (10) Potential plate weighing platform (11) Equipotential bonding clamp Mounting materials are enclosed with the ID7xx, IND690xx or IND4..xx weighing terminal. 4

4 Operating limits The weighing platform has such a rugged design that no damage should result if the maximum weighing capacity is occasionally exceeded. The static load-bearing capacity, i.e. the maximum permissible load, is dependent on the type of loading (positions A C). Maximum permissible load A KA15s KA32s A 50 kg 50 kg B 40 kg 40 kg C 30 kg 30 kg B C KB60 KCC150 KCC300 A 120 kg 500 kg B 80 kg 300 kg C 40 kg 150 kg A with central load B with side load C with one-sided corner load Falling loads, shocks and lateral impacts must be avoided. 5

5 Cleaning the weighing platform Maintenance of the weighing platform is limited to regular cleaning and subsequent oiling. The procedure depends both on the type of surface (powder-coated/enamelled or stainless steel) and on the environmental conditions prevailing at the installation location. Remove dirt and deposits at regular intervals from the outside and inside of the weighing platform. 5.1 Notes on cleaning CAUTION Incorrect use of cleaning agents may cause damage to the weighing platform! Use only such cleaning agents that do not act on the plastics used in the weighing platform. Be particularly careful when cleaning the measuring cell. Powder-coated/enamelled version, dry surroundings Wipe with a damp cloth. Use household cleaning agents. Stainless-steel version Wipe with a damp cloth. Water jet up to 60 C. Use household cleaning agents. Corrosive surroundings Water jet up to 60 C. Remove corrosive substances at regular intervals. Only use disinfectants and cleaning agents in accordance with the manufacturer's specifications and instructions. 6

5.2 Subsequent treatment Carry out the following subsequent treatment in order to protect the weighing platform: Rinse the weighing platform with clear water. Dry off the weighing platform with a lint-free cloth. Treat the inside and outside of the weighing platform with an oil suitable for foodstuffs. 5.3 Cleaning the measuring cell The load plate has to be removed in order to clean the measuring cell. Please refer to the next section for KCC weighing platforms. CAUTION The measuring cell can be damaged! During cleaning work, never touch, direct an airflow against or spray the rubber diaphragm (1) of the measuring cell. Blow out dirt or flush with a mediumpower water jet. 7

5.4 Removing and replacing the load plate at KCC weighing platforms Removing the load plate Remove the load plate by lifting the two side handles vertically (1.) and pivoting outward (2.). Replacing the load plate After mounting the load plate, swing the handles inward (3.) and reengage in initial position (4.), i.e. the handles must be in the bottom position and vertical. When the handles are correctly engaged, it should not be possible to lift off the load plate. 8

6 Standard accessories Order No. Stand Rigid frame construction 2 feet with casters 1 fixed foot with screw adjustment height approx. 560 mm for KB60 powder-coated/enamelled stainless steel for KCC150, KCC300 powder-coated/enamelled stainless steel Pillar support for KB60, KCC150, KCC300 for mounting ID1 Plus, ID3s or ID7 terminals on stand incl. fastenings powder-coated/enamelled stainless steel Scale stand for KA15s, KA32s, KB60 for mounting ID1 Plus or ID3s terminal on the weighing platform, all stainless steel 00 503 631 00 503 632 00 504 853 00 504 854 00 504 127 00 504 128 00 504 439 9

Order No. Roller track Steel-clad rollers with rust protection, for dry surroundings lengthwise motion for KB60 (8 rollers) for KCC150, KCC300 (9 rollers) Steel-clad rollers with rust protection, for wet surroundings lengthwise motion for KB60 (8 rollers) for KCC150, KCC300 (9 rollers) Extension cable Length 10 m, connector at both ends for remote setup of ID terminal 00 503 640 00 504 852 22 001 647 22 001 648 00 504 134 max. 95 m Cable adapter kit for ID terminals for infinite extension of connection cable to 100 m comprising two junction boxes Box at terminal end with connection cable of 2.5 m length 00 504 133 Special cable from the roll used with adapter kit for ID terminals for infinite extension of connection cable to required length 00 504 177 10

7 Technical data of the measuring cell 7.1 TBrick 15, TBrick 32 measuring cells Ignition protection type Power consumption IP protection type 7.2 Pik 15, K52 measuring cells Ignition protection type Power consumption IP protection type II 3G EEx na II C T6 10 C T a +40 C II 3D IP67 T 70 C The following safety-related variables must be ensured by the connected weighing terminal: Supply circuit U max, 20 V DC Interface circuit U max, CL 27 V DC I max, CL 30 ma U max Diff, RS422 10 V DC 12 V DC ± 20 %; 125 ma; 1.4 VA IP67 II 3G EEx na II C T4 +10 C T a +30 C 12 V DC + 10 % / 15 %; 150 ma; 1.8 VA 32 V DC + 10 % / 15 %; 100 ma; 3.2 VA IP67 EXPLOSION HAZARD Only use the measuring cell K52 in combination with the ID1Plus weighing terminal in Category 3G hazardous areas. The ID1Plus weighing terminal has to be installed in the safe area. 11

*22007212C* 22007212C Subject to technical changes Mettler-Toledo (Albstadt) GmbH 01/06 Printed in Germany 22007212C Mettler-Toledo (Albstadt) GmbH D-72458 Albstadt Tel. ++49-7431-14 0, Fax ++49-7431-14 232 Internet: http://www.mt.com