PRESSURE CONTROL VALVES SABS 198

Similar documents
COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Section - L. Antipollution devices

Components for central heating

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

TempControl Thermostatic Water Controllers

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

T Series (NPT) 2-Way and 3-Way Terminal Unit Zone Valves 1/2 3/4" 1. Applications. Features. Terminal Unit Zone Valves (NPT)

Single-Valve Powerstation

A. This Section includes the following domestic water piping specialties:

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Page Concealed Flush Valve (1976 on)

INSTALLATION & MAINTENANCE MODEL mm

Backflow Prevention. Quick Reference Guide

SECTION VALVES PART 1 -GENERAL

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

Technote. Frese ALPHA - automatic balancing valve. Application. Benefits. Features.

MADE IN THE USA BACKFLOW PREVENTERS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Photo: Swedish Coast Guard. Impeller Pumps

HERZ-Motorised flow controler

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

Product Catalogue November 2017

Taps, Valves & Components. Section 1

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting (15mm)

Valve Selection. 1. Function and service considerations

FLOW CONTROL. PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING SYSTEM COMPONENTS HEATING & COOLING DISTRIBUTION SYSTEMS

BEECO FLOW CONTROL

LEVER ACTION BALLVALVES

Fan-coil valves Series

TENOCHCA HALL - PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

Composite PEX-AL-PEX Tubing

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

GH Hydro Kits. Technical Information. Ref: N

Backflow Preventers & Accessories

A. This Section includes the following domestic water piping specialties:

SECTION METERS AND GAGES FOR PLUMBING PIPING

DOUBLE CHECK VALVES SERIES PRODUCT CODES OPERATION MEDIUM HAZARD RATING. 20mm - 50mm FEATURES APPLICATION SPECIFICATION STATEMENT DESCRIPTION

M3770: SOLENOID CONTROLLED / ELECTRICALLY POSITIONED VALVE - STEP BY STEP VALVE

THERMOSETTER Recirculation thermal balancing valve

Product Instructions. Diverting Valve. Valve Cross Section. Features. Specifications. Operations

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

OPERATION AND INSTALLATION

TECHNICAL SPECIFICATIONS 63/2E DN15 Kvmax /4"E. ( 3 4"x18) 3/4"E

dynacon floor heating manifold with automatic flow control

HIGH PRESSURE SPRAYERS

LK Manifold Shunt VS2

CIMBERIO VALVES. SAV Systems. Product Brochure.

Self-Operating Temperature Regulators

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

Open/close ball valves 2-port and changeover ball valves 3-port, PN40

40 geothermal ground loop manifolds

CALEFFI. Pre-assembled distribution manifolds for radiant panel systems. series 663 & /05 NA. Function

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SOLAR HEATING SYSTEM

Floor heating manifold with automatic flow control

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

CALEFFI. Pressure independent control valve (PICV) 145 series 01262/14 GB B 51

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

BERMAD Fire Protection

A range of shower fittings, precision engineered to provide an effective shower at all pressures. Available with either fixed or swivel heads

Gas Safety Shut-off Valve with thermally released Shut-off Device (TAE) DIN-DVGW for Gas: 695. Straight Pattern with TAE, Female End/Hose Union

Products for underfloor heating

HOSE BOXES. Includes hose boxes, supply boxes & hose valves MORRIS GROUP INTERNATIONAL

A. Provide all HVAC specialties required to complete the installation of all HVAC systems. B. Manufacturers: Refer to individual product item.

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Installation and Commissioning Instructions High Temperature Zone Module F31-1" (DN 25)

Two-port seat valves with male thread, PN16

Cash-Flo. Operation & Maintenance Manual. BackFLOW PREVENTERS. A Division of the Reliance Worldwide Corporation

Installation Instructions

SPECIFICATION: OPERATION: (Dimensional drawing on following page)

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Series 867 Reduced Pressure Zone Assemblies

R2F Compact Commissioning & 4 Port Control Valve Fan Coil Unit Valve Set Module

Bianco RainsaverMK4E Installation and Operating Instructions

LK 820 ThermoVar. Technical Data. Thermic Valves and Check Valves. Opening temperatures 45 C, 55 C, 61 C, 66 C, 72 C or 80 C.

* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

Installation Instructions

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

SOLDER RING FITTINGS GENERAL RANGE

VG6000 Series Forged Brass Valves

Thermal Expansion Absorber For Potable Water TX SERIES TANKS

4P-300 4V-500 CONTINUOUS PRESSURE THERMOPLASTIC DUAL. PRINCIPLE (U & Z Flow) DUAL CHECK VALVE. PRINCIPLE (Stn.Steel) REDUCED PRESSURE

PRESSURE REDUCING CONTROL VALVE

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

Installation, Operation & Maintenance Instructions for MF-Solar Series Solution Feeders

The Filling Procedure

Valves, controls + systems Stations for the connection heat generator/heating circuit

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Transcription:

PRESSURE CONTROL VALVES SABS 198 1 CALVALVE DOUBLE BLOCK Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge and strainer. Max. inlet pressure: 16 bar. Max. working temperature: 40 C. Supplied without Vacuum Breakers Pressure control combined pressure reducing valve and expansion relief valve, copper by copper compression ends. DZR alloy body. Replaceable cartridge and strainer. Max. inlet pressure: 16 bar Max. working temperature: 40 C. Supplied with 2 vacuum breakers. 533CV2-15 533CV4-15 533CV2-22 533CV4-22 533CV6-22 15mm Valve with relief 200kPa 15mm Valve with relief 400kPa 22mm Valve with relief 200kPa 22mm Valve with relief 400kPa 22mm Valve with relief 600kPa 533D2-15 15mm Double block 200kPa 533D4-15 15mm Double block 400kPa 533D2-22 22mm Double block 200kPa 533D4-22 22mm Double block 400kPa 533D6-22 22mm Double block 600kPa TRIBLOCK Pressure control - combined pressure reducing valve, expansion relief valve and integral ball-cock, copper x copper compression ends. DZR alloy body. Replaceable cartridge and internal strainer. Max inlet pressure 16 bar Max working temp 40 C Supplied with 2 Vacuum Breakers 533 T2-15 200kPa, 15mm,pcv with shutoff. 533 T4-15 400kPa, 15mm,pcv with shutoff. 533 T2-22 200kPa, 22mm,pcv with shutoff. 533 T4-22 400kPa, 22mm,pcv with shutoff. 533 T6-22 600kPa, 22mm,pcv with shutoff. MULTIBLOCK DESCRPTION 533M2-15 200kPa,15mm PCV Multiblock 533M4-15 400kPa,15mm PCV Multiblock 533 M2-22 200kPa, 22mm PCV Multiblock 533 M4-22 400kPa, 22mm PCV Multiblock 533 M6-22 600kPa, 22mm PCV Multiblock

CALFIX Replacement valve with expansion relief valve for where flat faced couplings and unions are used with fibre washers. 3/4" BSP Supplied without Vacuum Breakers. 533 CF2-20CFN 200kPa Replacement valve 533 CF4-20CFN 400kPa Replacement valve 533 CF6-20CFN 600kPa Replacement valve 2 Replacement valve for where flat faced couplings and unions are used with fibre washer. 3/4" BSP Supplied with two vacuum breakers and expansion relief valve 533 CF2-20CF 200kPa Replacement valve 533 CF4-20CF 400kPa Replacement valve 533 CF6-20CF 600kPa Replacement valve CALVAC VACUUM BREAKERS 15mm compression fitting 300-15 CF 15mm CxC vacuum breaker 22mm compression fitting 300-22 CF 22mm CxC vacuum breaker 22mm compression inlet and 15mm compression vent pipe connection. 300-22 CxC 22mm CxC vacuum breaker EXPANSION CONTROL VALVES Expansion control valve with stainless steel seat set into a DZR brass body. The fully flushable feature enables dirt or lime that accumulates on the seat to be flushed away by simply turning cap a quarter turn. 312-1 15mm expansion control valve 100kPa 312-2 15mm expansion control valve 200kPa 312-3 15mm expansion control valve 300kPa 312-4 15mm expansion control valve 400kPa 312-5 15mm expansion control valve 500kPa 312-6 15mm expansion control valve 600kPa

NON RETURN / BACKFLOW PREVENTERS 3 BF-22 Backflow preventer also available in 15mm BF-22 NR - 15 22mm CxC compression fitting 15mm CxC compression fitting REDUCED PRESSURE ZONE BACKFLOW PREVENTERS Controllable, reduced pressure zone backflow with anti siphon dump port. Dezincification resistant alloy body. Max working pressure: 1000kPa Max. working temperature: 65 C. Discharge opening differential ratio:14 kpa. To standard EN 12729. Connections 15-50mm MI unions, Note: A line strainer must be fitted upstream of all backflow preventers. Code SIZE 574-15 1/2" 574-20 3/4" 574-25 1" 574-32 1 1/4" 574-40 1 1/2" 574-50 2" 575-80 DN 80 575-100 DN 100 ADJUSTABLE PRESSURE REDUCING VALVES Pressure reducing valve with replaceable cartridge. Bronze body. Male union connections. Max. upstream pressure: 25 bar. Downstream setting pressure range: 0,5 6 bar. On request 6 10 bar. Max. working temperature: 80 C. Pressure gauge: upstream: 0 25 bar. Pressure gauge: downstream: 0 10 bar. Certified to EN 1567. Code SIZE 533-15 15mm CxC compression ends 533-22 22mm CxC compression ends 536-15 15mm MI Unions 536-20 20mm MI Unions 536-25 25mm MI Unions 536-32 32mm MI Unions 536-40 40mm MI Unions 536-50 50mm MI Unions 536-80 80mm Flanged 536-100 100mm Flanged INDUSTRIAL EXPANSION RELIEF VALVES Expansion relief valve max temperature 110 C 400kPa. 530-204 20 x 25 mm FI relief pressure 400kPa 530-254 25 x 32 mm FI relief pressure 400kPa 530-324 32 x 40mm FI relief pressure 400kPa

BALANCING VALVES Balancing valves for hydronic systems DZR alloy body. Stainless steel obturator complete with pressure ports. Max working pressure 16 bar Temp range -20 to 120 C DECRIPTION 130-15 15mm min 1.25 l/min, max 50l/min 130-20 20mm min 1.50 l/min, max 75 l/min 130-25 25mm min 2.0 l/min, max 100 l/min 130-32 32mm min 5.0 l/min, max 160 l/min 130-40 40mm min 6.0 l/min, max 250l/min 130-50 50mm min 8.0 l/min, max 416 l /min 4 THERMOSTATIC BALANCING VALVES Thermostatic Balancing valves for domestic hot water circulating circuits.dzr alloy body complete with temperature gauge. Max working pressure 10 bar Adjustment temp range 35-60 C 116240 15mm thermostatic balancing valve 116250 20mm thermostatic balancing valve AUTOMATIC AIR RELEASE VALVE Automatic air vent. In hot-stamped brass. Chrome plated. Max. working pressure: 10 bar. Max. discharge pressure: 4 bar. Max. working temperature: 120 C. 502241 15mm Automatic air release valve AUTOMATIC FLOW RATE REGULATORS DZR resistant alloy body, ploymer adjustable cartridge. Max working pressure 25 bar Temp range 0-100 C SIZE 118-15 15mm 118-20 20mm 118-25 25mm 118-32 32mm SELF CLEANING FLOW METERS Self cleaning flow meter flow rate scale 1-4 l/min Max working pressure 6 bar Max working temp 80 C 669050 20mm in line flow meter

THERMOSTATIC MIXING VALVES Adjustable anti-scald thermostatic mixing valve, Dezincification resistant alloy body. Max. working pressure: 14 bar (static) Max working pressure: 5 bar (dynamic) Max. inlet temperature: 85 C. Max. hot and cold water inlet pressure ratio 2:1 Performance in compliance to EN 1287 Note: An isolating valve, line strainer and nonreturn must be installed on the hot and cold supply. Code Size l/min 523-15 15mm 40 523-20 20mm 58 523-25 25mm 75 523-32 32mm 108 523-40 40mm 166 523-50 50mm 200 5 Adjustable thermostatic mixing valve. Brass body. Chrome plated. Max. working pressure: 10 bar. Max. inlet temperature: 90 C. Adjustment range 40 to 60 C 520540 3/4" BSP FI thermostatic controller WATER HAMMER ARRESTORS 15mm brass body chrome plated Max working pressure 10 bar Max working temp 90 C 525-15 15mm water hammer arrestor ANTI FREEZE VALVES Anti-freeze safety device. Dezincification resistant alloy body. Max. working pressure: 10 bar. Ambient temperature range: -30 90 C. Opening temperature: 3 C. Closing temperature: 4 C 603040 15mm anti freeze valve

TEMPERATURE GAUGES 6 In line temperature gauge Temp range 0-80 C 675050 22 mm In line temperature gauge PRESSURE GAUGES Stainless steel housing, glycerine filled pressure gauge. 593 - PG 0-1000kPa Back entry 693- PG 0-2500kPa Bottom entry Plumbers test kit with 1/2" and 3/4" BSP female adaptors comwith handy protective pouch. 590-PGS Plumbers test kit SPARE PARTS FOR PRESSURE CONTROL VALVES Spare cartridge for Adjustable pressure reducing valves for 536 Series. (15-50 mm) SIZE 536-C15 15mm 536-C20/25 20 and 25mm 536-C32/40 32 and 40 mm 536-C50 50mm Spare cartridge for 533 series pressure control valves.(15-20mm) SIZE 533000 15-20mm

SOLAR WATER HEATING SPECIFIC ITEMS SOLAR THERMOSTATIC MIXERS 7 Adjustable thermostatic mixing valve for Solar thermal systems. Chrome plated, DZR body. Male union connections Max working pressure 14 bar Max inlet temp 100 C 252150 22mm Solar thermostatic mixing valve 252140 15mm Solar thermostatic mixing valve AIR RELEASE VALVES Automatic air vent, brass body chrome plated. Max working pressure 10 bar Max discharge pressure 5 bar Temp range -30-180 C 250031 Automatic air release valve Comes with 3/8" x 1/2" BSP adaptor AIR RELEASE BALL COCKS 10mm MI x 10mm FI chrome plated ball cock for 250 air release valve. 250300 10mm MI x 10mm FI CP ball cock SOLAR EXPANSION RELIEF VALVES Expansion relief valve for Solar thermal systems, brass body CP. Temp range - 30-160 C Max % of glycole 50% Discharge rating 15mm, 50kw 253044 15mm FI x 20mm FI 400kPa 253046 15mm FI x 20mm FI 600kPa SOLAR TEMPERATURE AND PRESSURE SAFETY VALVES Temperature and pressure safety valve for Solar Thermal systems. DZR alloy body, chrome plated. Setting temp 90 C Discharge rating 25Kw 400kPa 309564 20mm 400kPa MI Safety Valve