STANDARD FEATURES. Flow Control Inlet

Similar documents
STANDARD FEATURES. Flow Control Inlet

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

SECTIONAL BODY STANDARD FEATURES. Enhanced Metering Section Available in Reversible Handle. Flow Control Inlet

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

SV SOLENOID OPERATED

SECTIONAL BODY. Series 20. Directional Control Valves STANDARD FEATURES SPECIFICATIONS VALVES. Pressure Rating

Service and Parts Manual. Minimum Filtration Required:

Series 34. Sectional Directional Control Valve Specifications: P34A Engineering & Manufacturing Solutions

CLS100 Proportional Load Sensing Mobile Valve

Monoblock Directional Control Valve PMB22TSTSAB PMB23TSTSTSLB PMB21TDLB

Full Range Pressure Compensating Variable Flow Control

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

Proportional Valves. Proportional solenoid valves for pressure and flow control

Contents. Quality Hydraulic Components from the Webtec Range. Introduction. Hydraulic Flow Control Valves

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

V050 SERIES DIRECTIONAL CONTROL VALVE

CLS180 Proportional Load Sensing Mobile Valve

Directional Control Valve CV550

V250 SERIES DIRECTIONAL CONTROL VALVES

MP18 Stacking Valve System Technical Information Manual

and RD5000 or by the Utility section in the Series 20 valves. 7. The internal pilot pressure is used to initiate the spool shift when a solenoid is en

Auxiliary valves. Lever. Spool positioner Check valve Spool

4 WAY DIRECTIONAL CONTROL VALVE AO

Commercial Shearing (Pty) Ltd THE WORLDWIDE PROGRAM OF VALVES ISO 9001

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

4-Way Directional Control With Pressure Compensated Flow Control PSDCF120M64LF Specifications:

Mobile Valves Proportional - Load Sensing

4-Way Directional Control Valve With Hydraulic Kick Out

Post-Compensated Proportional Valve CV2000LS

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

-Technical data... 2/14 -Circuit mode... 2/14 -Dimensions RP /14

MONOBLOCK DIRECTIONAL CONTROL VALVES

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

MP18/SIC & SIO Stacking Valve System Technical Information Manual

CONTINENTAL HYDRAULICS LPV SERIES AXIAL PISTON PUMPS

Vickers. Overhaul Manual. Directional Controls. CMX Sectional Directional Valve -25 Design. CMX100 & CMX160 Hydraulic & Electrohydraulic Actuation

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Eaton Directional Control Valves. h y d r a u l i c s. Models and 31930

DC Series. 4-Way Directional Control Valve With Or Without Flow Control PDC16T4PBS PDCF16TM454LF

36EFC. Series & EFC Valve Package

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

60VSERIES PFD-30 MSV-16 RV-30, RV-60. Muncie Power Products MP95-08 (Rev. 5-05) Printed in the U.S.A. Muncie Power Products, Inc VALVE WARRANTY

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

General Valve Assembly Information

17 SERIES DIRECTIONAL CONTROL VALVE

CONTROL SOLUTIONS FORKLIFT TRUCKS FORKLIFT TRUCKS

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

OPERATION AND PARTS MANUAL

Monobloc and Sectional Directional Control Valves

Series PVP Variable Volume Piston Pumps

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

2.3 MEDIUM HEAVY DUTY SERIES

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

90VSERIES DIRECTIONAL CONTROL VALVE MSV-16 RV-30, RV-60 PFD-30

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

Contents. Directional Control Valve 2 Series CV 300

HYDRAULIC CONTROL VALVES

Sectional Directional Control Valve RSQ 240

Pressure Control Valves

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

3PC Directional Control Valves

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

LogSplitterPlans.Com

Manual Proportional Directional Control Valve (with Pressure Compensation, Multiple Valve Series)

FULL RANGE PRESSURE COMPENSATING VARIABLE FLOW CONTROL

Series PAVC Variable Volume, Piston Pumps

Chapter 13: Application of Proportional Flow Control

10 FT./lbs. TORQUE FOR SOLENOID NUT MANUAL OVERIDE PIN GREY PLUG (85.3) 3.36 (74.7) SOLENOID "a" "B" PORT END (3.2) LOCATING PIN.

V5 60 LPM SECTIONAL SPOOL VALVE

Contents. Directional Control Valve 2 Series CV Unibody. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

VT modular. Modular System for LSC Manifold Valve Plates

VIS (Valve-In-Star) Hydraulic Motor

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Implement and Steering/Hydraulic System Testing and Adjusting

Hand-operated Hydraulic Control Valve 4- way 2-position 4 Ports

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

SERIES 20 SECTIONAL DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Lesson 5: Directional Control Valves

Directional Control Valve Series 4D01 (DENISON)

Pressure Control Valves. General Description. Specifications. Ordering Information

PRODUCT OVERVIEW. Our Mission:

Pilot Operated Pressure Relief Valve Series R5V (Denison)

P.C. Priority Flow Control Valve Series J02D3. General Description

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Eaton. h y d r a u l i c s. Models and with Pilot Operated Checks

Available manual, pneumatic, and hydraulic spool control kits.

Heavy Duty Hydrostatic Transmissions

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

SCX180 TECHNOLOGY DRIVEN CONTROL FOCUSED. SSL-1000 Rev. 4/11 Supercedes Rev. 3/11

SECTION A FRONT END LOADER VALVES

Chapter 10: Valves for Pipe Mounting

Transcription:

Directional Control Valves SECTIONAL BODY Model SV STANDARD FEATURES -0 Sections Per Valve Bank Differential Poppet Style Relief, Adjustable Load Checks On Each Section from 500 to 3000 psi (Also available in Low Pressure Hard Chrome Plated Spools Version Adjustable from 500 to 500 psi) Compact Construction Power Beyond Capability Enhanced Metering Section Available in Reversible Handle both the High and Low Sections Mid-Inlet and Lock Valve Section available Flow Control Inlet SPECIFICATIONS Parallel or Series Circuit Construction Foot Mounting Pressure Rating Maximum Operating Temp....80 F Maximum Operating Pressure... 3000 psi Weight Per Section Maximum Tank Pressure... 500 psi Inlet Section... Approx 3.75 Ibs Nominal Flow Rating...2 GPM Outlet Section... Approx 3.75 Ibs. Refer to Pressure Drop Curves. Work Section (Standard)... Approx 5.50 Ibs. Filtration: For general purpose valves, fluid Work Section (High)... Approx 8.00 Ibs. cleanliness should meet the ISO 440 9/7/4 level. For extended life or for pilot operated valves, the 8//3 fluid cleanliness level is recommended. CATV 29---0 O.E.M. CUSTOMER SERVICE: (72) 233-28 FAX (05) 235-082 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 V29

ORDERG FORMATION: The following is a listing of valve sections available from stock on a standard basis. STANDARD SECTIONS AVAILABLE: LET SECTIONS ALL HAVE BOTH TOP AND SIDE LET PORTS PART NO. RELIEF TYPE AND SETTG PORT SIZE SVI2 No Relief #0 SAE ORB (7/8-4 THD) SVI24 Adjustable Low Pressure Relief Set at 000 PSI #0 SAE ORB (7/8-4 THD) SVI5 Adjustable High Pressure Relief Set At 2000 PSI #8 SAE ORB (3/4- THD) SVI25 Adjustable High Pressure Relief Set at 2000 PSI #0 SAE ORB (7/8-4 THD) WORK SECTIONS ALL HAVE #8 SAE ORB (3/4- THD) PORTS, LOAD CHECK AND STANDARD LEVER HANDLE PART NO. SPOOL TYPE AND ACTION SVWAA SVWBA SVWBB SVWCA SVWCB SVWDD CA SVMES 3-Way Single Acting w/ Spring Center 4-Way Double Acting w/ Spring Center (Work Ports Blocked in Neutral) 4-Way Double Acting w/ 3 Position Detent (Work Ports Blocked in Neutral) 4-Way Motor Spool w/ Spring Center (Work Ports Open to Tank in Neutral) 4-Way Motor Spool w/ 3 Position Detent (Work Ports Open to Tank in Neutral) 4-Way 4 Position Float w/ Spring Center and Float Detent 4-Way Spool w/ Spring Center (with Pilot Operated Checks on Both Work Ports) 4-Way Meter Spool w/ Spring Center (Work Ports Blocked in Neutral) PORT RELIEF WORK SECTIONS ALL HAVE #8 SAE ORB (3/4- THD) PORTS, LOAD CHECK AND STANDARD LEVER HANDLE. MODELS WITH RELIEF FACTORY SET AT 2000 PSI AT 3 GPM. PART NO. SPOOL TYPE AND ACTION PORT RELIEFS SVHBAAA 4-Way Double Acting w/ Spring Center Port Relief Plugged SVHBAGG 4-Way Double Acting w/ Spring Center Adjustable 500-3000 PSI SVHDDAA 4-Way 4 Position Float w/ Spring Center and Float Detent Port Relief Plugged SVHDDBB 4-Way 4 Position Float w/ Spring Center and Float Detent Shim Adjustable 500-3000 PSI SVRESAA 4-Way Meter Spool w/ Spring Center Port Relief Plugged SVRESGG 4-Way Meter Spool w/ Spring Center Adjustable 500-3000 PSI SVSGAGG 4-Way Double Acting Series w/ Spring Center Adjustable 500-3000 PSI SVSGAAA 4-Way Double Acting Series w/ Spring Center Port Relief Plugged OUTLET SECTIONS ALL HAVE BOTH TOP AND SIDE OUTLET PORTS PART NO. EXHAUST OPTIONS PORT SIZE SVE Open Center Outlet w/ Conversion Plug #8 SAE ORB (3/4- THD) SVE2 Open Center Outlet w/ Conversion Plug #0 SAE ORB (7/8-4 THD) SVE22 Power Beyond Outlet w/ #8 SAE Power Beyond Port #0 SAE ORB (7/8-4 THD) SVE23 Closed Center Outlet #0 SAE ORB (7/8-4 THD) SVE2 Open Center Outlet Pressure Build-up Valve #0 SAE ORB (7/8-4 THD) SVE27 Power Beyond Pressure Build-up Valve #0 SAE ORB (7/8-4 THD) TIE ROD KITS TIE ROD TORQUE 50in-lbs ± in-lbs (2 /2 ft-lbs ±/2) PART NO. 04000 Section* 040002 2 Sections* 040003 3 Sections* 040004 4 Sections* 040005 5 Sections* *Number of Work Sections SPECIAL LET AND OUTLET SECTIONS AVAILABLE: PART NO. 04000 Sections* 040007 7 Sections* 040008 8 Sections* 040009 9 Sections* 04000 0 Sections* Sections other than standard models listed can be made to order. Use order code Matrix below to generate a model number that meets your requirements. If you prefer, contact your Sales Representative with your specific requirements and a model number will be assigned for you. This model number can be used for future orders. A minimum order quantity will apply to special valves. Please consult Sales Representative. LET SECTIONS S V I X X - X X X X PORT SIZE. #8 SAE ORB (3/4- THD) 2. #0 SAE ORB (7/8-4 THD) All inlet sections have top and side inlets. RELIEF SETTG (in PSI) RELIEF OPTION. No Relief Plug 4. Adj. Low Pressure 500-500 PSI 5. Adj. High Pressure 500-3000 PSI. Plastic Plug in relief cavity. Use only when cartridge is to be installed at a later date. OUTLET SECTION S V E X X PORT SIZE. #8 SAE ORB (3/4- THD) 2. #0 SAE ORB (7/8-4 THD) 0 Often used with no relief. Review application All outlet sections have top and side outlets. EXHAUST OPTION. Std. Open Center Outlet w/conversion Plug 2. Power Beyond Outlet w/#8 SAE Beyond Port 3. Closed Center Outlet 0 Open Center Outlet Pressure Build-up 7. Power Beyond Pressure Build-up #8 SAE Beyond Port V30 VALVE ASSEMBLIES The Model SV sectional body directional control valve can be ordered as separate sections or as a complete factory tested assembly. This will need to be specified with each order. An assembly number will be assigned at the time of the order. This assembly number can then be used for future orders. ASSEMBLY MODEL NUMBER SVA-XXXX XXXX = Sequence of Numbers. This number will be assigned to final valve to be assembled and tested at the factory. Each new order or quote will be assigned a new assembly model number. Please use quotation sheet at the end of SV section. O.E.M. CUSTOMER SERVICE: (05) 235-220 FAX (72) 233-28 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 SEE PAGE 4 OF THE STANDARD PRODUCT PRICE LIST FOR PRICG CATV 30---0

SPECIAL WORK SECTIONS AVAILABLE: Work Sections other than standard models listed can be made to order. Use order code Matrix below to generate a model number that meets your requirements. If you prefer, contact your Sales Representative with your specific requirements and a model number will be assigned for you. This model number can be used for future orders. A minimum order quantity will apply to special valves. Please consult Sales Representative. WORK SECTIONS S V X X X X X SECTION TYPE W-Std. Work Section M-Metering Work Section 2 L-Work Section with Double P.O. Checks F-Fine Metering 3 PORT SIZE. #8 SAE ORB (3/4- THD) 2. # SAE ORB (9/-8 THD) SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3 Position Motor D-4-Way 4 Position Float E-4-Way 3 Position Metering (SVM only) F-3-Way 3 Position Metering (SVM only) J-4-Way 3 Position Fine Metering (SVF only) K-4-Way 3 Position Counterbalance Drain (SVW) M-4-Way 3 Position Counterbalance Drain/Motor (SVM). Lock Valve Section available only with Spool Option C. 2. Metering Section available only with Spool Options E, F, or M. 3. Fine Metering available only with Spool Options J. PORT RELIEF WORK SECTIONS S V X X X X X X X SECTION TYPE H-Port Relief Section R-Port Relief Metering Section 2 S-Series Circuit Port Relief Section G-Port Relief Fine Metering Section 3 PORT SIZE.#8 SAE ORB (3/4- THD) 2.# SAE ORB (9/-8 THD) SPOOL TYPE A-3-Way 3-Position B-4-Way 3-Position C-4-Way 3 Position Motor D-4-Way 4 Position Float E-4-Way 3 Position Metering (SVR only) F-3-Way 3 Position Metering (SVR only) G-4-Way 3 Position Series (SVS only) H-4-Way 3 Position Motor Series (SVS only) J-4-Way 3 Position Fine Metering (SVG only) K-4-Way 3 Position Counterbalance Drain (SVH) M-4-Way 3 Position Counterbalance Drain/Motor (SVR) SPOOL ACTION A-Spring Center (SVH & SVS only) B- 3 Position Detent C-Friction Detent D- Spring Center w/ Float Detent (SVH only) E-Light Spring Center F-2 Position Detent Neutral and Out (No In Position) G-2 Position Neutral and Out Spring Offset to Out H-2 Position Neutral and In Spring Offset to In J-S/C with Micro Switch Bracket 2-Position* K-S/C with MicroSwitch Bracket -Position* M-Spring Center Detent In N-Spring Center Detent Out R-Spring Center Pneumatic Actuator S-Spring Center (SVR & SVG) *MicroSwitch not provided HANDLE OPTION. Standard Lever Handle 2. Less Handle Only 3. Less Complete Handle Assembly 4. Adjustable Handle 5. Tang Spool End Only. Clevis Spool End Only 7. Vertical Handle 9. Blank for Optional Joystick Handle 2. Extended Enclosed Handle HANDLE OPTION. Standard Lever Handle 2. Less Handle Only 3. Less Complete Handle Assembly 4. Adjustable Handle 5. Tang Spool End Only. Clevis Spool End Only 7. Vertical Handle 8. Straight Handle 9. Blank for Optional Joystick Handle. Enclosed Handle 2. Extended Enclosed Handle 3. Locking Handle SPOOL ACTION A-Spring Center (SVW & only) B-3 Position Detent C-Friction Detent D-Spring Center w/float Detent (SVW only) E-Light Spring Center F-2 Position Detent Neutral and Out (No Position) G-2 Position (Center and Spool Out) - Spring Loaded to Spool Out (Pressure to B Port) Position H-2 Position (Center and Spool ln)-spring Loaded to Spool In (Pressure to A Port) Position J-S/C with MicroSwitch Bracket 2-Position (MicroSwitch not provided) K-S/C with MicroSwitch Bracket -Position (MicroSwitch not provided) (activates on spool out only) M-Spring Center Detent In N-Spring Center Detent Out R-Spring Center Pneumatic Actuator S-Spring Center (SVM & SVF) PORT RELIEF B OPTION A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-500 PSI D-Anti-Cavitation Check E-Adjustable Combination Port Relief/Anti-Cavitation Check 000-2500 PSI*** F-Non-Adjustable Combination Port Relief/Anti-Cavitation Check 000-2500 PSI*** G-Adjustable Direct Acting Relief 500-3000 PSI H-Adjustable Direct Acting Relief 500-500 PSI PORT RELIEF A OPTION A-Relief Cavity Plugged B-Non-Adjustable Direct Acting Relief 500-3000 PSI C-Non-Adjustable Direct Acting Relief 500-500 PSI D-Anti-Cavitation Check **E-Adjustable Combination Port Relief/Anti-Cavitation Check 000-2500 PSI*** F-Non-Adjustable Combination Port Relief/Anti-Cavitation Check 000-2500 PSI*** **G-Adjustable Direct Acting Relief 500-3000 PSI **H-Adjustable Direct Acting Relief 500-500 PSI ** Cannot be used on work sections with float option due to interference with handle. *** Do not use in applications that require low work port leakage. Max allowable leakage 5 in 3 /min @000 psi. For Work Port Relief Settings Other Than Standard SVHBAGG-8-25 B PORT RELIEF PRESSURE HUNDREDS EXAMPLE: 25=2500 PSI at 3 GPM All Port Reliefs set at 3 GPM A PORT RELIEF PRESSURE HUNDREDS EXAMPLE: 8=800 PSI at 3 GPM All Port Reliefs set at 3 GPM CUSTOM SECTION: For OEM application custom sections can often be designed to meet your specifications. Special handles, spool, and spool actions are often easily made because of the SV valve s flexible design. Consult your sales representative with your specifications. CATV 3---0 O.E.M. CUSTOMER SERVICE: (72) 233-28 FAX (05) 235-082 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 SEE PAGE 5 OF THE STANDARD PRODUCT PRICE LIST FOR PRICG V3

FIELD CONVERSION KITS, REPAIR KITS AND RELIEF CARTRIDGES SPOOL ATTACHMENT KITS 08000 Spring Center Kit (except SVM) 080002 3 Position Detent Kit 080003 Friction Detent Kit 08005 Float Detent Kit 08003 Spring Center Detent In 080037 Spring Center Detent Out 08005 S/C w/micro-switch, 2 Position* 0800 S/C w/micro-switch, Position* HANDLE KITS 0800 Std. Handle Kit 080032 Clevis Sub-Assy 080005 Complete Handle Kit 08003 Pin Kit 08002 Vertical Handle Kit 080028 Straight Handle Kit 080007 Complete Adjustable Handle Kit 08000 Adjustable Handle Kit 080055 Joystick Handle Kit Less Handle *Bracket only, Micro-Switch is not provided. 080234 Locking Handle Kit 080033 Bent Joystick Handle Kit 08007 Straight Joystick Handle Kit 08008 Offset Joystick Handle Kit SEAL KITS 058000 SVW/SVM Replacement Seal Kit 0580002 Inlet Seal Kit 0580003 Outlet Seal Kit 0580004 Between Section Seal Kit 058000 SVH/SVR Replacement Seal Kit 0580009 Replacement Seal Kit 05800 SVS Replacement Seal Kit PORT RELIEFS 0280004 Port Relief Plug 0280003 Shim Adj. Port Relief 500-3000 PSI 028000 Shim Adj. Port Relief 500-500 PSI 028002 Adj. Combination Port Relief/Anti-Cav Check 000-2500 PSI 0280008 Shim Adj. Combination Port Relief/Anti-Cav Check 000-2500 PSI PERFORMANCE CURVES 0280005 Anti-Cavitation Check 0280009 Adj. Port Relief 500-3000 PSI 02800 Adj. Port Relief 500-500 PSI 720000.05 SHIM 7200002.033 SHIM 7200003.00 SHIM 08025 Shim Assortment LET RELIEFS 025000 Inlet Relief Plug 0250003 Adj. Low Pressure Inlet Relief 0250002 Adj. High Pressure Inlet Relief OUTLET CARTRIDGES 200400030 Open Center Plug 028000 #8 SAE Power Beyond Cart. 0280002 Closed Center Plug 028008 Open Center Build-Up Cart. 028009 Power Beyond Build-Up Cart. MISC. KITS 080052 Load Check Kit PRESSURE DROP P TO T 20 SUS OIL AT 00 F RELIEF VALVE CURVES PRESSURE DROP PSI 250 200 50 00 50 2 4 8 0 2 4 5 4 3 2 NO. OF WORK SECTIONS PRESSURE (PSI) 3000 2500 2000 500 000 2 4 8 0 2 4 PRESSURE DROP PSI 00 75 50 25 PRESSURE DROP P TO A OR B NO. OF WORK SECTIONS PRESSURE DROP PSI 00 75 50 25 PRESSURE DROP A OR B TO T 4 2 NO. OF WORK SECTIONS 2 4 8 0 2 4 2 4 8 0 2 4 SVS SERIES SECTION TEST DATA PRESSURE DROP PSI OPEN CENTER PRESSURE DROP P TO T 50 25 00 75 3 50 25 4 8 0 2 4 NO. OF WORK SECTIONS 20 SUS OIL AT 00 F PRESSURE DROP PSI OPEN CENTER PRESSURE DROP P-A-B-T 300 250 3 200 50 00 50 4 8 0 2 4 NO. OF WORK SECTIONS V32 O.E.M. CUSTOMER SERVICE: (05) 235-220 FAX (72) 233-28 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 CATV 32---0

DIMENSIONAL DATA B WORK PORT B WORK B WORK PORT PORT B WORK PORT WORK A WORK SECTIONS PORT A WORK A WORK PORT PORT A WORK PORT PART NUMBER WILL 2.8.7 BE STAMPED THIS LOCATION PART PART NUMBER TYPICAL NUMBER WILL WILL 2.8 2.8.7.7 BE BE STAMPED PART STAMPED NUMBER THIS THIS WILL SPOOL 2.8 TRAVEL SVW.7 LOCATION BE STAMPED TYPICAL TYPICAL THIS.250 TO WORK TYP. LOCATION TYPICAL SPOOL TRAVELSVW FLOAT OPTION SPOOL TRAVEL SVW.48 TO FLOAT TYP..250 TO SPOOL WORK TRAVEL TYP. SVW.250 TO WORK TYP. FLOAT FLOAT OPTION OPTION.48.48 TO TO FLOAT.250 FLOAT TO TYP. WORK TYP. TYP. FLOAT OPTION.25.48 TO FLOAT TYP. 2.9.25.25.25 2.9 2.9.55 2.9.55.55.50 5.34.55.50.50 5.34 5.34.50.3.88 5.34.3.3.88.88.3.50 5.34 SVH/SVR/ SVGSVH/SVR/.88 SVG SVH/SVR/ SVG SVG3.00.50.50 5.34 5.34.50 3.5 5.34.88 3.5 3.5 3.5.88.88.88.50 5.34 4. 3.00 3.00 3.00 4. 4. 4..50.50 5.34 5.34.50.3.88 5.34.3.3.88.88.3.88.25 TYP 3.00 4. 3.00 3.00 3.00 4. 4. 4. SVS SVS SVS SVS 3.00.25.25 TYP TYP.25 TYP 4. 3.00 3.00 3.00 4. 4. 4. TOP TOP LET LET TOP LET OUTLET COVER.75.50.75.50.75.50.75.50 CONVERSION PLUG PART NUMBER CONVERSION PLUG PLUG.94 SIDE TOP WILL BE STAMPED CONVERSION PLUG THIS LOCATION PART PART NUMBER NUMBER.94.94 SIDE SIDE OUTLET OUTLET WILL WILL BE BE STAMPED PART STAMPED NUMBER.94 SIDE OUTLET THIS WILL THIS LOCATION BE STAMPED THIS LOCATION 3.25 SVEXX 3.25 3.25 3.25 SVEXX SVEXX SVEXX.50.75.50.50.75.50.75 TOP LET.75 3.25 3.25 3.25 3.25.3 LET COVER 2.52 4.32 2.52 2.52.3.3 2.52 4.32 4.32.3 4.32 PART SIDE SIDE NUMBER LET LETWILL BE STAMPED SIDE THIS LETLOCATION PART PART NUMBER NUMBER WILL WILL BE BE STAMPED STAMPED PART NUMBER THIS THIS LOCATION WILL BE STAMPED THIS LOCATION BOTTOM VIEW OF MOUNTG DIMENSIONS SEE CHART COLUMN SEE B SEE CHART CHART SEE COLUMN COLUMN CHART B B COLUMN B.8.8.8.8 3.88 SIDE LET 3.88 3.88 3.88 3/8-UNC THD 3 PLACES 3/8-UNC 3/8-UNC THD THD 3 PLACES 3 PLACES 3/8-UNC THD.78 3 PLACES.78.78.78 SEE CHART COLUMN SEE A SEE CHART CHART SEE COLUMN COLUMN CHART A A COLUMN A.50.50.50.50 CATV 33---0 5.34 5.34 SPOOL TRAVEL 5.34.28 TO WORK TYP. 5.34SPOOL SPOOL TRAVEL TRAVEL 2.50.28.50.28 TO TO WORK SPOOL WORK TYP. TRAVEL TYP..22 2.50 2.50.50.28.50 TO WORK TYP..22 2.50.22.50.22.40 3.0.40.40.40 3.0 3.0 3.0.50 5.34.50.50 5.34 5.34.50 5.34 SVM/SVF SVM/SVF SVM/SVF.78.78.78 Number of Work Sections A B* 2.875 5.875 2 4.32 7.32 3 5.750 8.750 4 7.87 0.87 5 8.25.25 0.02 3.02 7.500 4.500 8 2.937 5.937 9 4.375 7.375 0 5.82 8.82 *With #0 plug in inlet & power beyond in outlet. O.E.M. CUSTOMER SERVICE: (72) 233-28 FAX (05) 235-082 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28.78 V33

TYPICAL STACK DIMENSIONAL DATA 7.44 7.44 2.50 2.50 5.58 5.58 SVEXX SVEXX C-590 C-590 THE ROD TORQUE 50 in-lbs + in - lbs (2 /2 ft - lbs +/2 7. 7..47.47 SIDE OUTLET SIDE OUTLET.47.47 9.30 2.0 9.30.95 2.0.95 8.59 8.59 POWER BEYOND PORT POWER 3.7 BEYOND PORT 3.7 SVE SVE SVH\SVS SVH\SVS SVM SVM SVW SVW -S2L -S2L -T2Q -T2Q SVI SVI 3.8 3.8 3.88 3.0 3.88 3.0 C-35 C-35 5.88 5.88 5.00 5.00 ENCLOSED HANDLE, OPTIONS AND 2 Durable die cast metal housing. Weather and oil resistant rubber boot. Reversible handle can be mounted in either a vertical or horizontal position. The extended handle option provides the necessary clearance for work port relief and lock cartridges. The extended handle option can also be used on the SVW and SVM, work sections when it is desired to keep handles aligned in an assembly with both low and high sections. 08049 = Option, enclosed handle kit 0805 = Option 2, extended enclosed handle kit 08050 = handle kit for enclosed handle options (handle, knob, hex nut) (handle kit is not included in the Option or 2 kits above) 2 8.73 STANDARD SECTION 23 2.03 Float position Alternate parallel handle position 0.2 PORT RELIEF SECTION Handle option (SVW & SVM) Handle option 2 (SVH,, SVS & SVR) V34 O.E.M. CUSTOMER SERVICE: (05) 235-220 FAX (72) 233-28 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 CATV 34---0

PARALLEL CIRCUIT SVW, SVM, SVF, SVH, SVR, SVG AND WORK SECTIONS Parallel circuit sections are by far the most common. The SVW, SVM, SVF, SVH, SVR, SVG and are all of parallel circuit construction. They can be combined together in any order in an assembly. When any one of the spools is shifted, it blocks off the open center passage through the valve. The oil then flows into the parallel circuit core making oil available to all spools. If more than one spool is fully shifted, the oil will go to the spool with the lowest pressure requirements. However, it is possible to meter the flow to the spool with the least load and provide flow to two unequal loads. ENHANCED METERG SECTIONS The SVM, SVF, SVR and SVG sections have metering notches machined into the spool to allow for better feathering of a load. The spool travel for these sections is also a little longer at.28 vs..250 for the standard sections. In addition to the metering notches in the spool, the lands in the SVF and SVG bodies have been machined to give more precise control over the flow. The metering notches in the SVF and SVG have been optimized for flows of 0 gpm or less. For enhanced metering on higher flows, it is recommended that the SVM or SVR be used. LOCK SECTIONS The section combines both a 4-way directional valve and a double pilot operated check valve. This provides very low leakage when the spool is in neutral. When the spool is shifted, oil is directed through a work port check to the cylinder. Pressure on the work port applies pressure to the shuttle spool, opening the opposite check valve and allowing oil to return into the valve. Depending on load pressures, the metering of the spool may be affected. In some cases a one way restrictor in a work port may be beneficial. SERIES CIRCUIT SVS WORK SECTIONS OPEN CENTER PASSAGE LOAD CHECK PARALLEL CIRCUIT CORE CONVERSION PLUG A series circuit valve is most commonly used to control more than one hydraulic component simultaneously. The entire circuit flow is available to each valve section that is actuated. In a two spool series valve with both spools actuated, the oil flows from the inlet to the work port of the first section. The return flow of the first section is directed to the open center core of the second section. TANK RETURN TANK RETURN (In a parallel valve the return oil from the work port is directed to the tank core.) From the open center core of the second section, the oil flows to the work port with the return oil going to the outlet. In a series circuit valve, the summation of the pressures required for each work section will equal the total pressure required for the circuit. The total pressure required must not exceed the system relief setting or the pump pressure rating. It is not required to have a SV Series section as the last section, unless series flow is required to a downstream valve. In this application, a power beyond plug must be used in the outlet section. COMBED SERIES / PARALLEL CIRCUITS SERIES SECTION SERIES SECTION The SV Series circuit valve sections may be stacked with SV parallel circuit valve sections. This allows both series and parallel control in the same valve assembly. In the valve assembly shown below, the first, third and fourth sections are parallel. The second section is series. The first parallel section has priority over all downstream valves. When the spool of the first parallel section is actuated, the return oil from the work port is directed to the tank core, thus oil flow to downstream sections is cut off. The second and third sections are in series with each other as is the second and fourth sections. The third and fourth sections are in parallel with each other. SERIES MOTOR SPOOL The SV Series Motor Spool provides control of reversible hydraulic motors. Both work ports are connected to the open center core in the neutral position. It should be noted that in the neutral position, the work ports will be equally pressurized to the same pressure that is required TANK RETURN TANK RETURN TANK RETURN TANK RETURN of any downstream valve sections and that a work port relief in the section will also limit the pressure of any other sections in the valve. The series motor spool should not be used to control a hydraulic cylinder as unwanted cylinder drift may occur in the neutral position. CLOSED CENTER APPLICATIONS The SV Series Circuit Valve sections cannot be used in a closed center valve assembly. PARALLEL SECTION SERIES SECTION PARALLEL SECTION PARALLEL SECTION P B A B A B A T CATV 35---0 O.E.M. CUSTOMER SERVICE: (72) 233-28 FAX (05) 235-082 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 V35

WORK SECTIONS SPOOL ATTACHMENT SPOOL ATTACHMENT OPTION OPTION B B 3 POSITION 3 POSITION DETENT DETENT (KIT NO. (KIT 080002), NO. 080002), B WORK B PORT WORK PORT POSITION POSITION DETENT DETENT OPTION OPTION C (080003) C (080003) 70300025 70300025 70700035 70700035 A WORK A PORT WORK PORT SVW SVW OPTION OPTION B B DOUBLE DOUBLE ACTG ACTG WORK WORK PORTS PORTS BLOCKED BLOCKED NEUTRAL NEUTRAL 230009009 230009009 70700034 70700034 OPTION OPTION B B 70700033 70700033 OPTION OPTION C C TANK CORE TANK CORE PARALLEL PARALLEL POWER POWER CORE CORE 4 WAY 34 POSITION WAY 3 POSITION A LOAD A CHECK LOAD CHECK IS STANDARD IS STANDARD ON EACH ON WORK EACH SECTION WORK SECTION SPOOL ATTACHMENT SPOOL ATTACHMENT OPTION OPTION A A SPRG SPRG CENTER CENTER (KIT NO. (KIT 08000) NO. 08000) SHUTTLE SHUTTLE SPOOL SPOOL LOCK VALVE LOCK VALVE CARTRIDGE CARTRIDGE 7400033 7400033 7400037 7400037 740003 740003 OPTION OPTION C C DOUBLE DOUBLE ACTG ACTG WORK WORK PORTS PORTS OPEN OPEN NEUTRAL NEUTRAL 790000 790000 70300030 70300030 70003008 70003008 70500044 70500044 POWER POWER CORES CORES 4 WAY 34 POSITION WAY 3 POSITION MOTOR MOTOR OPEN CENTER OPEN CENTER CORES CORES LOAD CHECK LOAD CHECK ADJUSTABLE ADJUSTABLE DIRECT DIRECT ACTG ACTG RELIEF RELIEF OPTION OPTION 'G' 'G' SPOOL ATTACHMENT SPOOL ATTACHMENT OPTION OPTION D D SPRG SPRG CENTER CENTER W/FLOAT W/FLOAT DETENT DETENT (KIT NO. (KIT 08005) NO. 08005) 70700037 70700037 70500048 70500048 7000009 7000009 230009009 230009009 ANTI-CAVITATION ANTI-CAVITATION CHECK CHECK OPTION OPTION 'D' 'D' ADJUSTABLE ADJUSTABLE HANDLE HANDLE OPTION OPTION 4 4 SVH SVH 7070003 7070003 70003027 70003027 OPTION OPTION D D 4 WAY DOUBLE 4 WAY DOUBLE ACTG ACTG WITH 4th WITH POSITION 4th POSITION FLOAT FLOAT 70500043 70500043 70300032 70300032 7030003 7030003 7200007 7200007 SV WORK PORT RELIEF* SV WORK PORT RELIEFS, OPTION B, C, G, & H CAN BE ORDERED PRETESTED. USE ORDER CODE AT RIGHT * Also used as standard main relief only models and RD400 models. PR PR - -O O - - MODEL MODEL NUMBER NUMBER PORT SIZE PORT SIZE RELIEF RELIEF TYPE TYPE PRESSURE PRESSURE SETTG SETTG 0 0 H- ADJUSTABLE H- ADJUSTABLE SPECIFY SPECIFY RELIEF RELIEF CARTRIDGE CARTRIDGE 500-3000 500-3000 PSI PSI PRESSURE. PRESSURE. ONLY ONLY L- ADJUSTABLE LEAVE BLANK FOR L- ADJUSTABLE LEAVE BLANK FOR 500-500 PSI STANDARD SETTGS. 500-500 PSI STANDARD SETTGS. NH- NON-ADJUSTABLE NH- NON-ADJUSTABLE 500-3000 PSISTANDARD STANDARD SETTG: SETTG: 500-3000 PSI NL- NON-ADJUSTABLE 2000 PSI 2000 for H PSI and for NHH and NH NL- NON-ADJUSTABLE 500-500 500-500 PSI PSI 000 PSI 000 for L PSI and for NLL and NL V3 O.E.M. CUSTOMER SERVICE: (05) 235-220 FAX (72) 233-28 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 SEE PAGE 7 OF THE STANDARD PRODUCT PRICE LIST FOR PRICG CATV 3---0

SV LET RELIEF OPTIONS OPTION NO RELIEF TOP LET This option provides no built in relief. This is used when a relief is provided elsewhere in the system or in a closed center application. This plug can be replaced with a relief cartridge at a later date. OPTION 4 LOW PRESSURE ADJUSTABLE RELIEF TOP LET This option provides for a differential poppet relief adjustable from 500-500 PSI. Set at 000 PSI @ 0 GPM. OPTION 5 HIGH PRESSURE ADJUSTABLE RELIEF This option provides for a differential poppet relief adjustable from SIDE LET 500-3000 PSI. Set at 2000 PSI @ 0 GPM. The differential poppet relief provides smooth quiet operation with high cracking pressure. RELIEF CARTRIDGES CAN BE ORDERED PRETESTED SEE RV-OX RELIEF, PAGE V7. SIDE LET SV OUTLET COVER OPTIONS POWER BEYOND PORT POWER BEYOND PORT SVEXX SIDE OUTLET "CC" STAMPED ON END OF SIDE OUTLET CLOSED CENTER PLUG OPTION 3 CLOSED CENTER OUTLET This option provides for closed center operation. This is typically used with a variable displacement pressure compensated pump or in a system with an unloading valve. When the spools are in neutral the inlet port is blocked. Closed center can also be accomplished by plugging the power beyond port of option 2..00.00 OPTION SVEXX STANDARD OPEN CEN- TER OUTLET WITH CONVERSION PLUG This is the standard outlet option. This option allows for conversion in the field for power beyond or closed center applications. When spools are in neutral the inlet is unloaded to tank. OPTION 2 POWER BEYOND OUTLET WITH #8 SAE BEYOND PORT This option provides for a high pressure power beyond port. This would be used if a valve is to be added down stream. THE OUTLET PORT MUST STILL BE CONNECTED TO TANK. When spools are in neutral the inlet is connected to the power beyond port. "CC" STAMPED ON END OF CLOSED CENTER PLUG.38.38 PLEASE NOTE that this closed center option does not provide for the drain off of standby spool leakage. This can allow a very small amount of oil to enter the work ports when in neutral. OPTION OPEN CENTER OUTLET PRESSURE BUILD- UP VALVE FOR SOLENOID OPTION This option directs oil from open center core thru pressure build-up valve and then to tank. See solenoid section for description of operation. OPTION 7 POWER BEYOND PRESSURE BUILD-UP VALVE FOR SOLENOID OPTION This option directs oil from inlet thru pressure build-up valve and then downstream. This pressure build-up valve provides a #8 SAE power beyond port. The outlet must be connected to tank. SV MID-LET SECTION MID LET PORT MID LET RELIEF SPACER SPLIT MID-LET SHOWN CAN BE CONVERTED TO COMBED MID-LET BY MOVG SPACER TO OPPOSITE END POWER CORE BLOCKG PLATE STALLS POWER CORE BETWEEN MID LET & UPSTREAM SECTION. SVIM X X - X X X X Last Four Digits Specify A Non-Standard Relief Pressure. When blank, refer to standard setting -No Relief 2-SHIM Adjustable 500-500 PSI Std. Setting 000 PSI @ 0GPM 3-SHIM Adjustable 500-3000 PSI Std. Setting 2000 PSI @ 0 GPM 4-Adjustable 500-500 PSI Std. Setting 000 PSI @ 0 GPM 5-Adjustable 500-3000 PSI Std. Setting 2000 PSI @ 0 GPM C-Combined Flow Mid-Inlet S-Split Flow Mid-Inlet (not available after a series section) See Section View at left. Note Location of Spacer, Part Number 7200035. Port Size #8 SAE ORB (3/4- THD) DESCRIPTION: A Mid-Inlet provides an inlet port for a second pump mid stream in the valve stack. A relief can be provided in this section. With the combined flow the flow from both pumps is available to the downstream sections when all the work sections upstream are in neutral. The split flow completely separates the two pump flows. The common tank passage is all that is shared between the two pump flows. Note: Split flow mid inlet is not available when used after a series section and the core block plate is not used after a series section. CATV 37---0 O.E.M. CUSTOMER SERVICE: (72) 233-28 FAX (05) 235-082 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 SEE PAGE 5 OF THE STANDARD PRODUCT PRICE LIST FOR PRICG V37

7300048 3 2 4 8 9 7300048 3 2 4 8 9 SV FLOW CONTROL LET SECTION S V I F X X X X X X PORT SIZE - Side and End Inlet #0 SAE ORB 2- Side and End Inlet #0 SAE ORB, with #8 SAE ORB External EF Circuit RELIEF VALVE - No Relief 2- Direct acting non-adjustable 500-500 psi set at 000 psi* 3- Direct acting non-adjustable 500-3000 psi set at 2000 psi* 4- Direct acting adjustable 500-500 psi set at 000 psi* 5- Direct acting adjustable 500-3000 psi set at 2000 psi* *for other settings please specify, i.e. SVIF5P2Q2700 is set at 2700 psi #0 Rear Inlet Port #0 Side Inlet Port EF SVIFXXX-XX Optional #8 EF Port SOLENOID OPTION Omit for Flow Control Option M 2Q-2VDC Double Spade Coil 24Q-24VDC Double Spade Coil 2H-2VDC D 4350 Coil 24H - 24VDC D 4350 Coil 2L-2VDC Double Lead Wire Coil 24L - 24VDC Double Lead Wire Coil 2W -2VDC Double Lead Wire w/ Weatherpak Connector Coil 24W - 24VDC Double Lead Wire w/ Weatherpak Connector Coil FLOW CONTROL OPTION M- Manual Flow Control P- Electro-Proportional U- Solenoid Unloading #0 Rear Inlet Port #0 Side Inlet Port EF SVIFXXX-XX C-70 Optional #8 EF Port 5.8 The SVIF Flow Control Inlet is interchangeable with the standard SV inlet section. FLOW CONTROL OPTIONS: P OPTION incorporates a solenoid operated, electrically variable pressurecompensated flow control cartridge. With the solenoid de-energized, all of the inlet flow is diverted to the tank core/ef port. By increasing the current through the solenoid, the flow directed to the power core and downstream sections will be proportionally increased, (the maximum rating of the cartridge is gpm at 500 ma) Control current is normally provided via a controller card providing, a PWM signal. U OPTION incorporates a solenoid operated, unloader cartridge. With the solenoid de-energized, all of the inlet flow is diverted to the tank core/ef port. With the solenoid energized all the inlet flow is directed to the power core and downstream sections. M OPTION incorporates a manually Option P- Proportional flow control with manual operated override pressure-compensated flow Option P- Proportional flow control cartridge. With the control knob control with manual 5.8 override turned fully in (clockwise), all of the inlet flow is diverted to the tank core/ EF port. By turning the flow control knob counter clockwise, the inlet flow directed to the power core and downstream sections is proportionally increased. Approximately 5 revolutions varies flow from no flow to full flow, C-70 PORT OPTION 2 The flow being directed to the tank core/ef port may be utilized by a second circuit by inserting a /4 pipe plug into the tank core passage on the seal side of the casting and then connecting the EF port to the second circuit. PRESSURE CORE PRESSURE PRESSURE CORE CORE CONTROL OPTION P CONTROL CONTROL OPTION POPTION U CIRCUIT PRESSURE SCHEMATIC CORE CIRCUIT SCHEMATIC CIRCUIT PRESSURE SCHEMATIC CORE CONTROL OPTION P CONTROL OPTION U CIRCUIT SCHEMATIC CIRCUIT SCHEMATIC PRESSURE PRESSURE CORE CORE CONTROL CONTROL OPTION OPTION U M CIRCUIT CIRCUIT SCHEMATIC PRESSURE SCHEMATIC CORE CONTROL OPTION M CIRCUIT SCHEMATIC PROPORTIONAL CONTROLLER BOX (for use with SVIFP flow control inlet), PART NO. 7300048 The proportional controller box is used to provide an adjustable electrical signal to a proportional solenoid on the SVIFP inlet. Once the dial is set, the regulated flow through the valve should remain approximately constant regardless of pressure. Within the operating range, flow varies approximately linearly with dial rotation. CONNECTIONS AND OPERATION: *Connect leads to the power supply and solenoid. Power supply should be between 9 and 32 VDC. OFF *With the power off, the inlet flow is directed to the tank (or excess flow port). *To provide power to the control, move the power switch to ON. -Black (Green LED is ON when control is powered). *Minimum flow is directed into the valve when 0 on the dial is aligned with the center mark. Maximum flow is directed into the valve when +Red 0 on the dial is aligned with the center mark. *Clockwise rotation increases flow. *Typically, no adjustments are needed for operation, (l-min and l-max pots are preset for the normal maximum and minimum flows) ON Power Switch Power Input RED+ BLACK- Power OK 0 +Red (2.50) (4.88) PRESSURE CORE CONTROL OPTION M CIRCUIT SCHEMATIC -Black Prince Manufacturing Corporation 5 7 0 SOL Output OFF ON Power Switch Power Input RED+ BLACK- Power OK (5.00) Prince Manufacturing Corporation 5 0 To proportional coil. Coil does not have polarity. To proportional coil. Coil does not have polarity. () 0 (4.3) 7 SOL Output () (5.00) (4.3) (5.75) (5.75) (2.50) (.24) Mount using three (4.88) #0-32 screws (not included) (.24) Mount using three Control comes #0-32 with screws ft (not of included) cable for power leads and ft of cable for coil leads. Control box protection rating is IP7. V38 O.E.M. CUSTOMER SERVICE: (05) 235-220 FAX (72) 233-28 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 SEE PAGE 5 OF THE STANDARD PRODUCT PRICE LIST FOR PRICG CATV 38---0

JOYSTICK HANDLE FOR MODEL SV STACK VALVE HANDLE BACK 5th SPOOL OUT SEE DETAIL AT LEFT HANDLE LEFT th SPOOL HANDLE HANDLE BACK BACK 5th SPOOL 5th SPOOL OUT OUT HANDLE RIGHT th SPOOL OUT SEE OFFSET DETAIL SEE DETAIL AT HANDLE LEFT AT LEFT SHOWN SEE DETAIL AT LEFT HANDLE VIEWED FROM TOP HANDLE HANDLE LEFT LEFT th SPOOL th SPOOL HANDLE FRONT 5th SPOOL HANDLE HANDLE RIGHT RIGHT th SPOOL th SPOOL OUT OUT This is a special handle for the model SV stack valve that allows the spools of two adjacent sections to be operated by one common handle. The spools can be operated independently HANDLE HANDLE VIEWED VIEWED or FROM FROM simultaneously TOP TOP depending on handle HANDLE HANDLE FRONT movement. FRONT 5th SPOOL 5th SPOOL The option is normally used on spring center to neutral sections, but can also be used on other sections such as float sections. This handle is normally installed on valves assembled at the factory but can be installed on work sections that have handle option 3 or 9. The drawing at right shows two joysticks with offset handles installed on a six section valve. When two joysticks are installed on the same valve assembly it is recommended that there be two standard sections between them to prevent handle interference. A two section spacer is available, part no. 0380002. OFFSET OFFSET HANDLE HANDLE SHOWN SHOWN OFFSET HANDLE SHOWN Please refer to these part numbers and state which sections the handle is to be installed on when ordering a valve assembly. This handle can be installed in the field to work sections with handle option 3 (no handle). JOYSTICK ASSEMBLY W/STRAIGHT HANDLE: ASSEMBLED ON VALVE...SVJS KIT... 08007 JOYSTICK ASSEMBLY W/OFFSET HANDLE: ASSEMBLED ON VALVE...SVJO KIT...08008 JOYSTICK ASSEMBLY W/BENT HANDLE: ASSEMBLED ON VALVE...SVJB KIT...080033 A molded rubber boot (73000) is available for the joystick. ONE WAY WORK PORT RESTRICTOR FOR SVH, SVM, SVR, SVF, SVS, SVG& WORK SECTIONS This restrictor will restrict oil in one direction and allow free flow in the opposite direction. This restrictor consists of an orifice plate that simply drops into the #8 SAE work port of a SVH, SVM, SVR, SVF, SVS, SVG & work section. Restricted Flow Free Flow ONE WAY WORK PORT RESTRICTOR FOR SVW WORK SECTIONS This restrictor will restrict oil in one direction and allow free flow in the opposite direction. This restrictor consists of the orifice plate as described at left and an adapter fitting that allow use in the standard SVW #8 SAE work port. Restricted Flow Free Flow Restricted Restricted Flow Flow Free Free Flow Flow Restricted Restricted Flow Flow Free Free Flow Flow ORDERG FORMATION HEX BRASS RESTRICTOR # SAE 9/-8 #8 SAE 3/4-7080XXX 70805XXX SQUARE STEEL RESTRICTOR 8XXX CONICAL SPRG The last three digits of part number are the orifice size in thousandths of an inch. EXAMPLE: # SAE 9/-8THD #8 SAE 3/4-THD 708002 7080502.02 ORIFICE 708025 7080525.25 ORIFICE 7080000 70805000 NO ORIFICE ORDERG FORMATION ADAPTER W/HEX BRASS RESTRICTOR # SAE 9/-8 #8 SAE 3/4-280XXX 80XXX ADAPTER WITH SQUARE STEEL 82XXX RESTRICTOR AND CONICAL SPRG The last three digits of part number are the orifice size in thousandths of an inch. EXAMPLE: # SAE 9/-8THD #8 SAE 3/4-THD 28002 8002.02 ORIFICE 28025 8025.25 ORIFICE 280000 80000 NO ORIFICE CATV 39---0 O.E.M. CUSTOMER SERVICE: (72) 233-28 FAX (05) 235-082 DISTRIBUTOR CUSTOMER SERVICE: PHONE (05) 235-220 FAX (72) 233-28 SEE PAGE 7 OF THE STANDARD PRODUCT PRICE LIST FOR PRICG V39