HIGH SECURITY VENTILATION LOUVRES

Similar documents
Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Highly resistant security materials and design to protect secure areas against combinations of manual attack, bullet, blast, and fire

INT Multipoint Range. Tindall Engineering Limited is registered in England and Wales - Company Number

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

Series KSG 1. Security Grilles INDEX

MOORGATE LOCK. Technical Details

Cell Ventilation Security Grille

Grilles & Diffusers. Series NV Non-vision grilles. Incorporating. Sight blocking design ensures privacy is maintained

WINDOW VENTILATION High quality, customisable, Surface Mounted and Glazed In options

Incorporating V2.1. Product spec >>> > Series WL - Standard weather louvres

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

Weather Louvre Test. Report 57668/1. Carried out for Seng Yoon Seng Holdings SDN. BHD. By Andrew Freeth. 14 January 2014

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

SERIES C. Adjustable Deflection Grilles for Circular Ducting

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

ISO Precision Racks Mfg. Co. BUREAU VERITAS Certification. Excluding Design

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

C O L M A N. Air Distribution TRANSFER GRILLES G SERIES SERIES

Incorporating V2.0. Product spec >>> > Series NV - Non vision grilles

BOLLARDS GATES BARRIERS BLOCKERS BOLLARDS PEDESTRIAN FRONTIER PITTS SECURITY BRITISH PERIMETER SECURITY SPECIALISTS

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

SERIES 701, , 151, 152 AV 1201/1401

Floor Swirls Models BZD and SZD

McKenzie Martin Louvres & Ventilation Systems Louvres Maximair Louvre Systems Turret Louvres

BL Series Louvres. Factory Assembled Louvre Panels

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

High Performance Axial Fans

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

LLC «Сenturion XXI st century» Limited Liability Company

MARINE MARINE & OFFSHORE DOORS

Louvre systems. Series WLD Weather louvre doors. Incorporating. Fully active louvre panel integrated into a door

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

PART F DIFFUSERS section 2 SEPT Publication. Air Diffusers. supply and exhaust ventilation systems. drum jet diffusers

WG-38 SERIES. 38mm PITCH LOUVRES. 38mm PITCH LOUVRES

Ambulance Vehicle Engineering Specialist vehicles built to serve you

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

Police Vehicle Engineering Specialist vehicles built to serve you

(click on page links below) XAL-2C Technical Data 1. XAL-4C Technical Data 3

BOLLARDS GATES BARRIERS BLOCKERS BOLLARDS PEDESTRIAN FRONTIER PITTS SECURITY BRITISH PERIMETER SECURITY SPECIALISTS

ACOUSTIC CONTAINER RANGE

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

Louvre systems. Series WLSS / WLG Stainless / galvanised steel weather louvres. Incorporating

All over the world our clients are secure in the knowledge they are protected... PENMAN PROTECTED TM

Ceiling swirl diffusers

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Think Triumph. Think Lockers.

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

FlowBar High Capacity Slot Diffuser

SERIES H. Heavy Duty Adjustable Deflection Grilles

TransShield Mode 1/2. Transfer Stainless Steel Sliding Plate Fire Dampers.

SERIES H. Heavy Duty Adjustable Deflection Grilles

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

VITE LOVE WORK A PRACTICAL AND VERSATILE WORK CHAIR. IT S SIMPLICITY MAKES IT THE IDEAL CHAIR FOR THE MODERN WORKING OFFICE.

VERAK S-MAX 19 standard cabinet for server

Catalogue. FlowBar. High Capacity Slot Diffuser.

It s as simple as A,B,C...

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

USS - External Louvre. Halton USS. External Louvre

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

PUNKAH LOUVRES - PKL DESCRIPTION & FEATURES

SERIES K. Fixed Blade Grilles

Linear Floor Grilles Models FG, F20, F25 and FRO

Tel: Sales: STORAGE CABINETS. PREMIERSHIELD anti-bacterial powder coating system. quality products made in the UK

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Type WG-JZ COMBINATION WITH A MULTILEAF DAMPER. PÁGINA PRINCIPAL > Productos > Rejas para intemperie - compuertas de regulación

Ceiling swirl diffusers

MOTORIZED VOLUME DAMPER

designed, engineered and fitted... without compromise

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

Blast tested to 100kg and now 500kg charges and also IED devices

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

BenchTop Extraction Arm FX2

Power Distribution Enclosures. Pillar shells and in-ground feeder pillars

Master Plus kva

Onesource. Onecompany. The only. solution. The Integrated Rack System

Rotating Power AC Motors and Generators

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

Actionair Control and Shut Off Dampers

Stannah Midilift SL/GL

HIGH PERFORMANCE WIND TURBINES KW6

3M Driver Feedback Sign DFS 700

LINEAR SLOT DUFFUSERS

CONTROL SMOKE AND BALANCING DAMPERS

a total louvre design and manufacturing service

Ventilation grilles for installation into walls, sills or rectangular

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

SERIES GZL. High Induction Linear Diffuser (Patented)

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

Transcription:

VERSION CONTROL: 14-02-17 HIGH SECURITY VENTILATION LOUVRES Safe & Secure with Surelock McGill 1 Tel: Tel: +44 +44 (0) (0) 118 118977 9772525

HIGH SECURITY VENTILATION LOUVRES Enables the Maximum Free without Compromising Security Applications These heavy duty steel Louvres are ideal for a wide range of applications including server rooms, generator housings, air conditioning systems, sub stations and so on. They can be made to almost any size to suit a wide range of ventilation requirements. Anti-Ligature Features The unique Surelock McGill Anti-Ligature Louvre Range is used in areas such as seclusion rooms, secure hospitals, generator housings and prisons. Finishes Surelock McGill have been manufacturing and installing high performance door locking and bolting systems, as well as ancillary products, for over 50 years. Intensive research and development, together with the embracing of new technologies and materials as they evolve, means that our products provide the most robust and sophisticated security available. Our products are tested for their resistance to many forms of threat (for example, security, designed, tested and certi ed for the health and safety duty of care that is required today. re, blast, ballistic attack). They are also The development of new products has been integrated with our regime of testing and approvals to maintain the supply of products with certi cation to important UK and European standards throughout the process. Hostile Environments Surelock McGill products are widely used on offshore oil platforms and generally in the petro-chemical industry. This is due, in part, to their resistance to the privations of such environments. The same considerations and their inherent resilience also lead to their use in securing remote stations used by police response units and the armed forces. Total Commitment, Comprehensive Service Surelock McGill offers a comprehensive service to ensure integrity and security: Operational analysis and technical advice Site survey and scheduling Product manufacture and supply Bespoke design systems Installation Planned maintenance On-going support Standard packages Customer Care Surelock McGill customer care is second to none. That is why we can boast an exceptional level of customer loyalty. Solid business relationships have been built on the trust earned by our dedication to providing the best security solution for every challenge that our customers confront us with. Quality Statement Our continued commitment to product excellence and accreditation to ISO 9001: 2008 throughout the group ensures unequalled customer satisfaction and is our Seal of Excellence. Applicable Standards and Accreditations: ASSESSED TO ISO 9001: 2008 CERTIFICATE NO. 516 Quality ISO 9001: 2008 CE marking of conformity Security LPS 1175 See individual product pages for details of approvals gained. 2 Tel: +44 (0) 118 977 2525

MAX-AIR XA0 VENTILATION LOUVRE Construction - Mild Steel or Stainless Steel Finish - Natural, Primer or a colour of your choice Clear Clear XA0-400-400-MS N/A 400 400 Mild Steel N/A XA0-400-400-S4 N/A 400 400 304 Stainless Steel N/A XA0-400-400-S6 N/A 400 400 316 Stainless Steel N/A Standard size to suit a 400mm by 400mm clear opening. Louvres to suit clear openings between 125mm by 125mm to 900mm by 900mm available on request. Arrays of multiple units are available when using the Max-Air framing system. XA0 400 400 S4-0 wide clear opening, 304 Stainless 400mm x 400mm (0.4m x 0.4m) Unit: Steel, Button Head Fixings. Structural opening in wall (SO) = 0.4 x 0.4 = 0.16m² Louvre opening width (L) = (structural opening width - 0.068) = 0.4-0.068 = 0.332m Number of Louvred openings (N) = ((structural opening 0.12 / 0.04) + 1) = (0.4-0.12/0.04)+1 = 8 Airflow factor (A) = 0.008685 Louvre free area (FA) = L x N x A = 0.332 x 8 x 0.008685 = 0.02306736m² Area of slotted zone (SZ) = (Louvre opening width (L) x (Number of Louvred s (N)x0.04+0.02)) = 0.332 x (8x0.04+0.02) = 0.332 x 0.34 = 0.11288m² Free airflow percentage = FA/SZ = 0.02306736m² / 0.11288 = 20.4% Note: The value on the examples is based on air figure constant and does not include any type of mesh. Face Velocity (FV) = Airflow (m³/s) / Area of slotted zone (SZ) Pressure drop ( p) = 44.3 x Face Velocity (FV)2 For Airflow = 0.022m³/s and Structural opening in wall (SO) = 0.4m x 0.4m = 0.16m² Face Velocity = 0.022 / 0.11288m² = 0.2 m/s Hence the static pressure drop p = = 44.3 x 0.22 = 1.772 Pa. Countersunk Fixings instead of Button Head Fixings on the inside Tel: +44 (0) 118 977 2525 3

MAX-AIR XA1 SECURITY APPROVED VENTILATION LOUVRE Construction - Mild Steel or Stainless Steel Finish - Natural, Primer or a colour of your choice Clear Clear XA1-400-400-MS-B SR1 400 400 Mild Steel XA1-400-400-MS-H SR1 400 400 Mild Steel XA1-400-400-S4-B SR1 400 400 304 Stainless Steel XA1-400-400-S4-H SR1 400 400 304 Stainless Steel XA1-400-400-S6-B SR1 400 400 316 Stainless Steel XA1-400-400-S6-H SR1 400 400 316 Stainless Steel XA1 400 400 S4-H-0 wide clear opening, 304 Stainless Steel, Hand Access, Button Head Fixings. Standard size to suit a 400mm by 400mm clear opening. Louvres to suit clear openings between 125mm by 125mm to 900mm by 900mm available on request. Arrays of multiple units are available when using the Max-Air framing system. 400mm x 400mm (0.4m x 0.4m) Unit: Structural opening in wall (SO) = 0.4 x 0.4 = 0.16m² Louvre opening width (L) = (structural opening width - 0.068) = 0.4-0.068 = 0.332m Number of Louvred openings (N) = ((structural opening 0.12 / 0.04) + 1) = (0.4-0.12/0.04)+1 = 8 Airflow factor (A) = 0.008685 Louvre free area (FA) = L x N x A = 0.332 x 8 x 0.008685 = 0.02306736m² Area of slotted zone (SZ) = (Louvre opening width (L) x (Number of Louvred s (N)x0.04+0.02)) = 0.332 x (8x0.04+0.02) = 0.332 x 0.34 = 0.11288m² Free airflow percentage = FA/SZ = 0.02306736m² / 0.11288 = 20.4% Note: The value on the examples is based on air figure constant and does not include any type of mesh. Face Velocity (FV) = Airflow (m³/s) / Area of slotted zone (SZ) Pressure drop ( p) = 44.3 x Face Velocity (FV)2 For Airflow = 0.022m³/s and Structural opening in wall (SO) = 0.4m x 0.4m = 0.16m² Face Velocity = 0.022 / 0.11288m² = 0.2 m/s Hence the static pressure drop p = = 44.3 x 0.22 = 1.772 Pa. Countersunk Fixings instead of Button Head Fixings on the inside 4 Tel: +44 (0) 118 977 2525

MAX-AIR XA2 SECURITY APPROVED VENTILATION LOUVRE Construction - Mild Steel or Stainless Steel Finish - Natural, Primer or a colour of your choice Clear Clear XA2-400-400-MS-B SR2 400 400 Mild Steel XA2-400-400-MS-H SR2 400 400 Mild Steel XA2-400-400-S4-B SR2 400 400 304 Stainless Steel XA2-400-400-S4-H SR2 400 400 304 Stainless Steel XA2-400-400-S6-B SR2 400 400 316 Stainless Steel XA2-400-400-S6-H SR2 400 400 316 Stainless Steel XA2 400 400 S4-H-0 wide clear opening, 304 Stainless Steel, Hand Access, Button Head Fixings. Standard size to suit a 400mm by 400mm clear opening. Louvres to suit clear openings between 125mm by 125mm to 900mm by 900mm available on request. Arrays of multiple units are available when using the Max-Air framing system. 400mm x 400mm (0.4m x 0.4m) Unit: Structural opening in wall (SO) = 0.4 x 0.4 = 0.16m² Louvre opening width (L) = (structural opening width - 0.068) = 0.4-0.068 = 0.332m Number of Louvred openings (N) = ((structural opening 0.12 / 0.04) + 1) = (0.4-0.12/0.04)+1 = 8 Airflow factor (A) = 0.008685 Louvre free area (FA) = L x N x A = 0.332 x 8 x 0.008685 = 0.02306736m² Area of slotted zone (SZ) = (Louvre opening width (L) x (Number of Louvred s (N)x0.04+0.02)) = 0.332 x (8x0.04+0.02) = 0.332 x 0.34 = 0.11288m² Free airflow percentage = FA/SZ = 0.02306736m² / 0.11288 = 20.4% Note: The value on the examples is based on air figure constant and does not include any type of mesh. Face Velocity (FV) = Airflow (m³/s) / Area of slotted zone (SZ) Pressure drop ( p) = 44.3 x Face Velocity (FV)2 For Airflow = 0.022m³/s and Structural opening in wall (SO) = 0.4m x 0.4m = 0.16m² Face Velocity = 0.022 / 0.11288m² = 0.2 m/s Hence the static pressure drop p = = 44.3 x 0.22 = 1.772 Pa. Countersunk Fixings instead of Button Head Fixings on the inside Tel: +44 (0) 118 977 2525 5

MAX-AIR XA3 SECURITY APPROVED VENTILATION LOUVRE Construction - Stainless Steel Finish - Natural, Primer or a colour of your choice Clear Clear XA3-400-400-S4-B SR3 400 400 304 Stainless Steel XA3-400-400-S4-H SR3 400 400 304 Stainless Steel XA3-400-400-S6-B SR3 400 400 316 Stainless Steel XA3-400-400-S6-H SR3 400 400 316 Stainless Steel XA3 400 400 S4-H-0 Standard size to suit a 400mm by 400mm clear opening. Louvres to suit clear openings between 125mm by 125mm to 900mm by 900mm available on request. Arrays of multiple units are available when using the Max-Air framing system. wide clear opening, 304 Stainless Steel, Hand Access, Button Head Fixings. 400mm x 400mm (0.4m x 0.4m) Unit: Structural opening in wall (SO) = 0.4 x 0.4 = 0.16m² Louvre opening width (L) = (structural opening width - 0.068) = 0.4-0.068 = 0.332m Number of Louvred openings (N) = ((structural opening 0.12 / 0.04) + 1) = (0.4-0.12/0.04)+1 = 8 Airflow factor (A) = 0.008685 Louvre free area (FA) = L x N x A = 0.332 x 8 x 0.008685 = 0.02306736m² Area of slotted zone (SZ) = (Louvre opening width (L) x (Number of Louvred s (N)x0.04+0.02)) = 0.332 x (8x0.04+0.02) = 0.332 x 0.34 = 0.11288m2 Free airflow percentage = FA/SZ = 0.02306736m² / 0.11288 = 20.4% Note: The value on the examples is based on air figure constant and does not include any type of mesh. Face Velocity (FV) = Airflow (m³/s) / Area of slotted zone (SZ) Pressure drop ( p) = 44.3 x Face Velocity (FV)2 For Airflow = 0.022m³/s and Structural opening in wall (SO) = 0.4m x 0.4m = 0.16m² Face Velocity = 0.022 / 0.11288m² = 0.2 m/s Hence the static pressure drop p = = 44.3 x 0.22 = 1.772 Pa. Test 100kg at 15m, 250KPa Countersunk Fixings instead of Button Head Fixings on the inside 6 Tel: +44 (0) 118 977 2525

MAX-AIR XA4 SECURITY APPROVED VENTILATION LOUVRE Construction - Stainless Steel Finish - Natural, Primer or a colour of your choice Clear Clear XA4-400-400-S4-B SR4 400 400 304 Stainless Steel XA4-400-400-S4-H SR4 400 400 304 Stainless Steel XA4-400-400-S6-B SR4 400 400 316 Stainless Steel XA4-400-400-S6-H SR4 400 400 316 Stainless Steel XA4 400 400 S4-H-0 Standard size to suit a 400mm by 400mm clear opening. Louvres to suit clear openings between 125mm by 125mm to 900mm by 900mm available on request. Arrays of multiple units are available when using the Max-Air framing system. wide clear opening, 304 Stainless Steel, Hand Access, Button Head Fixings. 400mm x 400mm (0.4m x 0.4m) Unit: Structural opening in wall (SO) = 0.4 x 0.4 = 0.16m² Louvre opening width (L) = (structural opening width - 0.068) = 0.4-0.068 = 0.332m Number of Louvred openings (N) = ((structural opening 0.12 / 0.04) + 1) = (0.4-0.12/0.04)+1 = 8 Airflow factor (A) = 0.008685 for XA4-B, 0.00651375 for XA4-H Louvre free area (FA) = L x N x A = 0.332 x 8 x 0.008685 = 0.02306736m² for XA4-B, 0.01730052m2 for XA4-H Area of slotted zone (SZ) = (Louvre opening width (L) x (Number of Louvred s (N)x0.04+0.02)) = 0.332 x (8x0.04+0.02) = 0.332 x 0.34 = 0.11288m² Free airflow percentage = FA/SZ = 0.02306736m² / 0.11288 = 20.4% for XA4-B, 15.3% for XA4-H Note: The value on the examples is based on air figure constant and does not include any type of mesh. Face Velocity (FV) = Airflow (m³/s) / Area of slotted zone (SZ) Pressure drop ( p) = 44.3 x Face Velocity (FV)2 For Airflow = 0.022m³/s and Structural opening in wall (SO) = 0.4m x 0.4m = 0.16m² Face Velocity = 0.022 / 0.11288m² = 0.2 m/s Hence the static pressure drop p = = 44.3 x 0.22 = 1.772 Pa. Test 100kg at 15m, 250KPa Countersunk Fixings instead of Button Head Fixings on the inside Tel: +44 (0) 118 977 2525 7

MAX-AIR XA5 SECURITY APPROVED VENTILATION LOUVRE Construction - Stainless Steel Finish - Natural, Primer or a colour of your choice Clear Clear XA5-400-400-S4-B SR5 400 400 304 Stainless Steel XA5-400-400-S4-H SR5 400 400 304 Stainless Steel XA5-400-400-S6-B SR5 400 400 316 Stainless Steel XA5-400-400-S6-H SR5 400 400 316 Stainless Steel XA5 400 400 S4-H-0 Standard size to suit a 400mm by 400mm clear opening. Louvres to suit clear openings between 125mm by 125mm to 900mm by 900mm available on request. Arrays of multiple units are available when using the Max-Air framing system. wide clear opening, 304 Stainless Steel, Hand Access, Button Head Fixings. 400mm x 400mm (0.4m x 0.4m) Unit: Structural opening in wall (SO) = 0.4 x 0.4 = 0.16m² Louvre opening width (L) = (structural opening width - 0.068) = 0.4-0.068 = 0.332m Number of Louvred openings (N) = ((structural opening 0.12 / 0.04) + 1) = (0.4-0.12/0.04)+1 = 8 Airflow factor (A) = 0.00651375 Louvre free area (FA) = L x N x A = 0.332 x 8 x 0.00651375 = 0.01730052m² Area of slotted zone (SZ) = (Louvre opening width (L) x (Number of Louvred s (N)x0.04+0.02)) = 0.332 x (8x0.04+0.02) = 0.332 x 0.34 = 0.11288m² Free airflow percentage = FA/SZ = 0.01730052m² / 0.11288 = 15.3% Note: The value on the examples is based on air figure constant and does not include any type of mesh. Face Velocity (FV) = Airflow (m³/s) / Area of slotted zone (SZ) Pressure drop ( p) = 44.3 x Face Velocity (FV)2 For Airflow = 0.022m³/s and Structural opening in wall (SO) = 0.4m x 0.4m = 0.16m² Face Velocity = 0.022 / 0.11288m² = 0.2 m/s Hence the static pressure drop p = = 44.3 x 0.22 = 1.772 Pa. Test 100kg at 15m, 250KPa Countersunk Fixings instead of Button Head Fixings on the inside 8 Tel: +44 (0) 118 977 2525

* H versions only Approved for UK Government Use, for details contact CPNI. MAX-AIR XA6 SECURITY APPROVED VENTILATION LOUVRE Construction - Stainless Steel Finish - Natural, Primer or a colour of your choice Clear Clear XA6-400-400-S4-B SR6 400 400 304 Stainless Steel XA6-400-400-S4-H SR6 400 400 304 Stainless Steel XA6-400-400-S6-B SR6 400 400 316 Stainless Steel XA6-400-400-S6-H SR6 400 400 316 Stainless Steel XA6 400 400 S4-H-0 Standard size to suit a 400mm by 400mm clear opening. Louvres to suit clear openings between 125mm by 125mm to 900mm by 900mm available on request. Arrays of multiple units are available when using the Max-Air framing system. wide clear opening, 304 Stainless Steel, Hand Access, Button Head Fixings. 400mm x 400mm (0.4m x 0.4m) Unit: Structural opening in wall (SO) = 0.4 x 0.4 = 0.16m² Louvre opening width (L) = (structural opening width - 0.068) = 0.4-0.068 = 0.332m Number of Louvred openings (N) = ((structural opening 0.12 / 0.04) + 1) = (0.4-0.12/0.04)+1 = 8 Airflow factor (A) = 0.00651375 Louvre free area (FA) = L x N x A = 0.332 x 8 x 0.00651375 = 0.01730052m² Area of slotted zone (SZ) = (Louvre opening width (L) x (Number of Louvred s (N)x0.04+0.02)) = 0.332 x (8x0.04+0.02) = 0.332 x 0.34 = 0.11288m² Free airflow percentage = FA/SZ = 0.01730052m² / 0.11288 = 15.3% Note: The value on the examples is based on air figure constant and does not include any type of mesh. Face Velocity (FV) = Airflow (m³/s) / Area of slotted zone (SZ) Pressure drop ( p) = 44.3 x Face Velocity (FV)2 For Airflow = 0.022m³/s and Structural opening in wall (SO) = 0.4m x 0.4m = 0.16m² Face Velocity = 0.022 / 0.11288m² = 0.2 m/s Hence the static pressure drop p = = 44.3 x 0.22 = 1.772 Pa. Test 100kg at 15m, 250KPa Countersunk Fixings instead of Button Head Fixings on the inside Tel: +44 (0) 118 977 2525 9

BLACKWATCH SECURITY VENTILATION LOUVRE Construction - Heavy Duty Steel Tested Size - 1,000mm x 1,000mm Finish - As standard powder coated Grey / White Leatherette or alternatively in a colour of your choice Clear Clear BWC4-300-300-MS-B SR4 300 300 Steel 30% BWC4-300-300-MS-H SR4 300 300 Steel Contact us BWC4-500-500-MS-B SR4 500 500 Steel BWC4-500-500-MS-H SR4 500 500 Steel 30% Contact us BWC4-500-750-MS-B SR4 500 750 Steel 30% BWC4-500-750-MS-H SR4 500 750 Steel Contact us BWC4-300-300-MS-H-0 BWC4-500-1000-MS-B SR4 500 1000 Steel BWC4-500-1000-MS-H SR4 500 1000 Steel BWR4-(width)-()- MS-B SR4 350 to 1150 350 to 2500 Steel 30% Contact us 30% by 300mm wide clear opening, Steel, Hand Access, Button Head Fixings. BWR4-300-300-MS-H-0 by 300mm wide clear opening, Steel, Hand Access, Button Head Fixings. Air flow percentages are rounded down to the nearest whole number. 600mm x 600mm (0.6m x 0.6m) Unit: Louvre area: 544mm x 540mm = 0.544m x 0.540m = 0.29376m² Gaps between blades: 13 of 0.544 x 0.01326 = 13 of 0.0072134 = 0.0937742m² Free air flow percentage: 0.0937742 x100 = 31% (rounded down to nearest whole number) 0.2937600 Pressure drop across Louvre as a function of approaching flow velocity (high flow velocities). Using Bernoulli s equation, it can be shown that for a parallel duct system that exhausts into, or takes air from the atmosphere, p/q = 1 + P/q. Total non-dimensional static pressure drop for 0.2m/s flow rate, p/q = 1 + P/q = 1 + 6.71 + 3.02 = 10.73 Louvre Slotted plate Hence the static pressure drop p = 10.73 x (½ x 1.2 x 0.2²) = 0.26 Pa. Static Pressure Drop (Pascals) 200 150 100 50 0 1 2 3 4 5 Face Velocity (m/s) 10 Tel: +44 (0) 118 977 2525

Approved for UK Government Use, for details contact CPNI. COLDSTREAM SECURITY LEVEL LOUVRE High Performance Ventilation Louvre Construction - Heavy Duty Steel or Stainless Steel Tested Size - 1,000mm x 1,000mm Finish - As standard powder coated Grey / White Leatherette or alternatively in a colour of your choice Clear Clear CSC-300-300-MS 300 300 Steel Contact us 30% CSC-600-600-MS 600 600 Steel Contact us 30% CSC-1000-1000-MS 1000 1000 Steel Contact us 30% Air flow percentages are rounded down to the nearest whole number. 600mm x 600mm (0.6m x 0.6m) Unit: Louvre area: 544mm x 540mm = 0.544m x 0.540m = 0.29376m² Gaps between blades: 32 of 0.168 x 0.01326 = 32 of 0.0022276 = 0.0712832m² 14 of 0.074 x 0.01326 = 14 of 0.0009812 = 0.0137368m² 03 of 0.168 x 0.00791 = 03 of 0.0013288 = 0.0039864m² 0.0712832m² + 0.0137368m² + 0.0039864m² = 0.0890064m² CSC-300-300-MS-H-0 wide clear opening, Steel, Button Head Fixings. Free air flow percentage: 0.0890064 x100 0.2937600 =30% (rounded down to nearest whole number) Note: does not include any type of mesh. Vibration Alarm - Sensor Connected to Louvre Blade Covert Fixings Tel: +44 (0) 118 977 2525 11

Approved for UK Government Use, for details contact CPNI. GRENADIER SECURITY VENTILATION LOUVRE High Performance Ventilation Louvre Construction - Heavy Duty Steel or Stainless Steel. With Anti Drill and Anti Cutting Back Plate detail Tested Size - 1,000mm x 1,000mm Finish - As standard powder coated Grey / White Leatherette or alternatively in a colour of your choice Clear Clear GDC-300-300-MS 300 300 Steel Contact us GDC-600-600-MS 600 600 Steel Contact us 30% GDC-1000-1000-MS 1000 1000 Steel Contact us 32% Air flow percentages are rounded down to the nearest whole number. 600mm x 600mm (0.6m x 0.6m) Unit: GDC-300-300-MS-H-0 wide clear opening, Steel, Button Head Fixings. Louvre area: 544mm x 540mm = 0.544m x 0.540m = 0.29376m² Gaps between blades: 11 of 0.544 x 0.01476 = 11 of 0.0080294 = 0.0883234m² Free air flow percentage: 0.0883234 x100 0.2937600 =30% (rounded down to nearest whole number) Note: does not include any type of mesh. Vibration Alarm - Sensor Connected to Louvre Blade Covert Fixings 12 Tel: +44 (0) 118 977 2525

SECURE ROOM ANTI-LIGATURE VENTILATION LOUVRE High Performance Ventilation Louvre designed and approved for use in Special Hospitals where there is a ligature risk. Special Hospitals Seclusion Rooms Prisons Heavy Duty Steel construction Vanes fully welded top and bottom to wall fabric Pin-Torx Security Screw Fixing of the Louvre to the Flange Fixing Plate Wall aperture size 380mm x 380mm Finish - Powder coated cream gloss as standard, other colours available, by request < Flange Fixing Plate Clear Clear ALS-500-500-MS N/A 500 500 Steel N/A 69% Air flow percentages are rounded down to the nearest whole number. 380mm x 380mm (0.38m x 0.38m) Unit: Louvre area: Area of a trapezium = ½ x h x ( a + b ) = 0.5 x 0.340m x ( 0.280m + 0.352598m) = 0.1075417m² ALS-500-500-MS wide clear opening, Steel. Area covered: Centre column area = 0.040m x 0.340m = 0.0136m² Blades area = 14 of 0.003m x 0.340m = 0.01428m² Angled shelf area = 2 of 0.016823m x 0.156299m = 0.0052588m² Total area covered = 0.0331388m² Louvre area Total area covered = Gaps between blades. 0.1075417m² - 0.0331388m² = 0.0744029m² Free air flow percentage: 0.0744029 x100 0.1075417 =69% (rounded down to nearest whole number) Note: any type of mesh. Tel: +44 (0) 118 977 2525 13

BLAST AND BALLISTIC SAFETY LOUVRES AND VENTS Louvers for walls, doors and screens Modular for large areas Ballistic Louvres tested to European and American standards automatic closing Blast Vents Internal Catch Trays to mitigate deliberate external attacks with flammable liquids Construction - Stainless Steel or Mild Steel Finish - Natural, Primer or a colour of your choice Blast Louvres Blast Vents Flammable liquids thrown in to louvre Internal catch tray Louvres made to order to suit any opening size. Please contact us with your requirements. Accelerant - Internal Stainless Steel Mesh shield with bevelled run out Countersunk Fixings instead of Button Head Fixings on the inside Insect mesh within the Louvre Flammable liquids returned to outside of building 14 Tel: +44 (0) 118 977 2525

MAX-AIR FRAMING SYSTEM Aperture in walls greater than 900mm by 900mm The Max-Air Framing System can be used to combine arrays of to 7500mm by 7500mm F External view F-F (0.16:1) Internal view Frame opening G F Frame opening width Tel: +44 (0) 118 977 2525 15

Safe & Secure with Surelock McGill Some of the sectors we cover ELECTRICITY GAS NUCLEAR WIND WATER OFFSHORE / PETROCHEM BANKING CASH IN TRANSIT ATMs SECURE HOSPITALS AIRPORTS RAIL TELECOMS DATA CENTRES DEFENCE COURTS & PRISONS GOUVERNMENT EDUCATION 26 The Business Centre, Molly Millars Lane, Wokingham, Berkshire RG41 2QY. United Kingdom Telephone: +44 (0) 118 977 2525 Facsimile: +44 (0) 118 977 1913 Email: sales@surelock.co.uk Web: Intellectual Property Rights All Surelock products are the subject of intellectual property rights. These rights include patent and design rights, in particular UK patents 2346927, 2413822, 2423787, 2439327, 2458893 & EP2311/2115252, US5865479, US8616591, together with other overseas patents and further applications. In accordance with our policy of continued development and improvement we reserve the right to make changes in design and specifications without notice. ASSESSED TO ISO 9OO1:2008 CERTIFICATE NO. 516