ELECTRONIC CONTROL ACTUATOR

Similar documents
ELECTRONIC CONTROL ACTUATOR

ELECTRONIC CONTROL ACTUATOR

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd.

BATTERY BACK-UP ROTARY ACTUATOR ESD-BB-S ESD-BB-M ESD-BB-L OPERATION MANUAL

Unic-20 / 40 Close Side Limit Switch Adjustment. (Factory Default Position) 0 90 deg. Close Position Set Screw. Open Position Set Screw

Installation, Operation and Maintenance Manual

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

User s Manual. Pneumatic Positioner. Series 58. J Flow. Series 58. J Flow

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

Control Valves Positioner

Control Valves Positioner

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

Linear Valve Electric Actuator

Type SAM-01 to Type SAM-52 Electric Actuators. Type SAM-20, 30 mm rated travel, 6 kn thrust. Mounting and Operating Instructions EB 8330 EN

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

Motorized Two-Way Ball Valve with Screwed-End Connection

EX Series. Electric Actuators for Ball and Butterfly Valves

Operating Instructions. Angle Seat Control Valve. Type 7020

Electrical Actuator HH-500 REsearch COntrol

Pneumatic Positioner PNY Series USER'S MANUAL. Max-Air Technology. Version 1.0

TOWA SEIDEN INDUSTRIAL CO., LTD.

Pneumatic Actuators. TGA Specifications

SERVO-TOP II ELECTRONIC ACTUATOR

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)

Pneumatic Positioner RTX - Series USER S MANUAL. ROTEX P/P Ver. 0.1 Dated: MAY / 2009 REV 01: SEP/2010 Page 1 of 16

Installation, Maintenance and Operation Manual

Type Operating Instructions. Angle Seat Motor Valve Compact. BM24C, BM24C/I BM24C/IOS, BM230C/IOS with and without spring return

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

HL (AZH) Limit Switches

AE Installation Operation & Maintenance Instructions

YT-1200 Series VERSION 1.02

Installation and Operating Manual

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

TG-S Specifications TG-12S Rc3/8. 6 to 20

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications

HL (AZH) LIMIT SWITCHES

Electro-Pneumatic Positioner YT-1000 / 1050 SERIES

EDDY CURRENT VARIABLE SPEED DRIVE CONTROLLER - TYPE PM-07

5-Phase Stepper Motor

Direct Coupled Damper Actuator Model MY6050A1001

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

HL (AZH) Limit Switches

Pressure Transmitter

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

V4(V7)-ABFW-EPN16 Actuated Wafer type butterfly valves

Electric Actuator Installation, Operation & Maintenance Manual

HQ Series ¼ Turn Electric Actuator

PERFORMANCE IP67 (IEC60529, JIS C 0920) Silver contact: Max.50 mω (6 to 8 Vdc, energizing current 1A, measured by voltage drop method) Gold alloy cros

Operation Manual Electro-Pneumatic Positioner Model: NT-1000R (Rotary Type) NUTORK CORPORATION

EX Series. Electric Actuators for Ball and Butterfly Valves

ROGOWSKI LEAK METER MODEL RLM-1

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Actuated Valves. Product Information

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

SAX Electronic Valve Actuator

RTX1000 SERIES ELECTRO-PNEUMATIC POSITIONER

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

Spring Cylinder Rotary Actuator

2-PHASE STEPPING SYSTEMS. Ver.5

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A)

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

4.3 MSK SWITCH BOX MSK (SIZE I) FEATURES ADVANTAGES

VA-7000 SERIES ACTUATOR

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS

Quarter Master Series 94 Actuator

Electro-Pneumatic Positioner RTX - Series USER S MANUAL. ROTEX E/P Ver. 0.1 Dated: dd / mm / yy Page 1 of 18

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

Electric Modulating Actuator Installation, Operation & Maintenance Manual

Motor-drive mechanism, type BUL. Technical guide

D4DL. Guard Lock Safety-door Switch. Model Number Structure

SS2 Linear / Rotary Smart Valve Positioner

CENTAC Inlet and Bypass Valve Positioners

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Baelz-electrodyn Actuator for modulating duty Motorized linear actuator baelz 373-E45

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

HQ Series ¼ Turn Electric Actuator

ACTIVAL Motorized Two-Way Valve with Flanged-End Connection for High Differential Pressure Application (JIS 10K-FC200, -SCS13A)

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

2-Way & 3-Way Non Spring Return Characterized Ball Valves

350 Series Electrohydraulic Actuators

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

HQ-006 ¼ Turn Actuator

Pneumatic Cylinder. 3I Double-acting type. 3Q Single-acting type (spring returned type)

Transcription:

ELECTRONIC CONTROL ACTUATOR Nucom Series LINEAR TYPE Nucom L50S OPERATION MANUAL Koei Industry Co., Ltd.

FOR YOUR SAFETY In order for better and safety use of the product for a long period, please observe this WARNING and CAUTION carefully. Here are the specification and operation manual for the product to prevent suffering injury or loss by accidents. The contents are divided into WARNING and CAUTION for different degree of risks. Please strictly observe them, as both of them are very important for your safety. WARNING: Improper handling of the product disregarding the notes under this mark may cause injury or death to a man. CAUTION: Improper handling of the product disregarding the notes under this mark may cause injury or material loss. WARNING * This product is not of explosion-proof. Do not use it in the environment with flammable gas (gasoline etc.) or corrosive gas. * Do not dismantle the actuator from the valve during power operation. * Do not make wiring work when power is being supplied. CAUTION * Do not drop the product or give a shock to the product, for it may cause defects to the product. * Do not get on the actuator, or it may cause defects or an accident. * Do not make wiring work in the rain or in splashing water.

CONTENTS 1. GENERAL 2. CONFIGURATION AND NAMES OF PARTS 3. FUNCTIONAL SPECIFICATION 4. OPERATION PRINCIPLE 5. INSTALLATION 5-1 Installation place 5-2 Ambient temperature, fluid temperature 6. ASSEMBLY WITH A VALVE 7. WIRING 7-1 Wiring with power / input signal 7-2 Wiring work 8. RATED POWER, INPUT SIGNAL AND WIRING DIAGRAM 8-1 Rated power 8-2 Input signal 8-3 Recommendable fuse or breaker 8-4 Wiring diagram 9. CONTROL PACK 9-1 Names of parts 9-2 Mode selection 9-3 Sensitivity volume and ZERO / SPAN adjustment 10. OPERATION 10-1 Manual operation 10-2 Power operation 11. MAINTENANCE / INSPECTION 12. TROUBLE SHOOTING

1.GENERAL ACT-N05E-3 The system is a linear type Electronic Actuator to continuously position valve opening with direct signals (4 ~ 20mA) from a controller or computer. The system is robust, maintenance free and far more precise (Resolution 1/250) than traditional pneumatic actuators, and will help save process equipment and running costs. FEATURES * Compact and light * High resolution (More than 1/250) * Direct / reverse action selectable by mode selection switch * Open/Close/Stop mode during power interruption selectable by mode selection switch * Resin-molded servo control pack for water and vibration proof * Helps simplify process flow * Saves process equipment and running costs to one over decades compared with pneumatic system. * Torque limiter and impedance protection motor to prevent motor burnout. 2. CONFIGURATION AND NAMES OF PARTS FIG.1-1-

3. FUNCTIONAL SPECIFICATION ITEM RATED VOLTAGE INPUT SIGNAL MODEL Nucom-L50S AC100/110/115/120V±10% (50/60 Hz) AC200/220/230/240V±10% (50/60 Hz) 4~20mA DC(1~5V DC) (Standard ) 4~12/ 12~20 ma DC(Option ) SHAFT OUTPUT OPERATION SPEED SHAFT STROKE 1,470N(150kgf) 1.25mm/sec(50Hz) 1.50mm/sec(60Hz) 0~50mm RESOLUTION Over 1/250 DEAD ZONE LINEARITY ACTION MODE MODE DURING SIGNAL OFF PROTECTION AMBIENT TEMPERATURE 0.5% F.S. 0.5% F.S. Direct(DA), Reverse(RA) Selectable Close/Open/Stop Selectable Top position limit switch (Standard) Bottom position torque limiter (Standard) Thermal protector (Standard) 25~55 C RATED CURRENT 0.22A(AC100V) 0.25mA(AC110V) MOTOR DUTY RATING POSITION DETECTION OUTPUE SIGNAL INSULATION RESISTANCE WITHSTAND VOLTAGE TERMINAL MANUAL OVERRIDE 8W reversible motor Class E Continuous Potentiometer CONDUIT G1/2 2 WATER PROTECTION EXPLOSION PROOF MOUNTING ANGLE BODY MATERIAL COATING WEIGHT 1~5V DC (Output impedance 1kΩ) 500V DC/100MΩbetween terminal and body 1000V AC/1 minute between motor coil and body 6-pin terminal block (Control pack) Allen key (Opposite 4mm) To IP-65 Non-explosion proof Angle free Die cast aluminum (ADC12) Grey (Munsell scale N-6) Approx. 3.2kg -2-

4.OPERATION PRINCIPLE ACT-N05E-3 Control pack (Electronic module) makes relational operation between input signals (4~20mA) and position signals detected by potentiometer, and drives motor in direction to balance both the signals. Motor stops at the position where both the signals are balanced. Motor revolution (Direct and reverse) is transmitted in the order of Gear head 2-Speed gear A 2-Speed gear B Spur gear C Screw shaft, then converted into linear movement to stroke main shaft up and down. Potentiometer always detects the shaft position and feedbacks it to control pack. The sequence of the above movement allows the system to continuously perform proportional operation against input signals. < Block Diagram > Spur gear C 2-Speed gear 2-Speed gear A Screw shaft Potentiometer Moter Output Nut thrust ACTION Power source Output signal Input signal Regulato AC/DC Amp. circuit RA/DA changeov Differentia circuit Control Power source Compariso circuit OFF mode Drive circuit -3-

CAUTION ON ENVIRONMENTAL INSTALLATION CONDITIONS 5. INSTALLATION 5-1 Installation place Caution on indoor installation * The actuator is not of explosion-proof type. Avoid installation in a hazardous place. * Cover whole the unit, when installing it in a place where water or materials are always splashing.. * It is recommendable to reserve a space for manual maintenance work. (depends on installation conditions) Caution on outdoor installation * Cover or shade whole the unit, and avoid rainwater or direct sunlight,. (This may cause temperature rise in the unit, or may effect on anti-climate property of seals ) * It is recommendable to reserve a space for manual maintenance work. (depends on installation conditions) Actuator surface materials and treatment PART BODY BASE BODY COVER MODEL Nucom-L50S Die cast Aluminum Oxidation treatment Electrostatic coating Die cast Aluminum Oxidation treatment Electrostatic coating OUTPUT SHAFT SUS 303 DUST COVER ON MANUAL OVERRIDE NBR OIL SEAL NBR 5-2 Ambient temperature / fluid temperature Ambient temperature * Environmental temperature range for use : 25 C~55 C. * For use in minus temperature, space-heater is available at option. * For use in temperature beyond the specified range, refer to our Sales Dept. Fluid temperature It is occasional that if the actuator is applied to a high temperature fluid line, the unit may overheat with transmitted line heat. For high temperature application, we suggest using radiation type yoke and coupling. -4-

CAUTION ON ASSEMBLY WITH A VALVE 6. ASSEMBLY WITH A VALVE Names of parts Actuator FIG.3 As shown in Fig.3, actuator and valve are individually structured for easy dismounting when trouble is occurred. Assembly procedures 1. Be sure that power is off before making manual operation. 2. Drive the valve manually and confirm that it is normal. Then set it at full close position. 3. Fit a bracket to the actuator. 4. After the actuator is set at full close, couple output shaft and the valve stem with coupling. 5. Manually drive the actuator, and make sure that it moves smoothly without eccentricity. 7. WIRING CAUTION ON WIRING WORK Bracket Coupling Valve 7-1 Wiring of power and signal cables Remove the side plate cover (or body cover), and find 6-P terminal block inside. Cover Set screw Control pack Terminal Conduit FIG.4-5-

Caution on wiring A qualified person based on electric equipment technical standard should make wiring work. Refrain from wiring work under rainy or high humid conditions. Make proper wiring to the wiring diagram. For all connections use fork crimped-on terminals. For the standard resin conduit, use a cable of outer diameter φ9~11mm. (Refer to Fig.5) For customer conduit, select a proper size cable to match it and avoid water ingress through the gap. Secure the cover and conduit tightly after wiring is over and avoid water ingress. Body Rubber bush Cable φ9~φ11 G1/2 O-ring Seal FIG.5 7-2 Wiring work Use sufficiently shield tubes or conduit to prevent water ingress. (Top) (Top) (Bottom) Branch (Bottom) Branch FIG.6-6-

CAUTION ON USE 8. RATED POWER / INPUT SIGNAL AND WIRING DIAGRAM 8-1 Rated power AC 100/110/115/120V±10% (50/60Hz) AC 200/220/230/240V±10% (50/60Hz) For different supply from the above, refer to our Sales Dept. 8-2 Input signal 4~20mA DC (1~5V DC) 4~12mA DC 12~20mA DC Standard Option Option Note: Wiring should be made properly to reject noise disturbance etc. 8-3 Recommendable fuse or breaker Install a protection fuse or breaker on supply source referring to the following table Model Capacity of fuse / breaker Motor capacity Nucom-L50S 2A 8W 8-4 Wiring diagram -7-

CAUTION 9. CONTROL PACK 9-1 Names of parts ON USE No. Name Terminal block for 1 custom wiring 2 ZERO trimmer 3 SPAN trimmer 4 GAIN trimmer 5 Direction mode switch Mode switch for 6 Signal Off Connector for 7 internal wiring(cn-1) ACT-N05E-3 1 2 3 4 5 6 7 FIG.8 9-2 Mode selection Input signal and operation direction Direct or reverse action is selectable by Select switch. Slide left for Direct Action Input signal 20mA bottom(close) 4mA top(open) (SW1) (SW2) Slide right for Reverse Action Input signal 20mA top(open) 4mA bottom (close) Mode select switch for DA/RA mode (slide switch) FIG.9 Action during signal interruption When signal circuits are open or a signal is lowered below 2mA during operation, the system recognizes as signal interrupted, and stops movement at the preset position by Select switch. Slide left for stop at top position (open) (SW1) (SW2) Keep center for stop at the existing position (stop) Slide right for stop at bottom position (close) Mode select switch for Signal Off mode (slide switch) FIG.10 Note : Before setting a direction or action mode, be sure that power is off. -8-

* Direct / reverse direction and action mode during signal interruption (signal off ) may be set in the following 6 combinations. FIG.11 * Unless expressly instructed, the unit is preset before shipment in the following combination: Action mode Signal OFF mode RA Stop Note : Adjust 4~20mA signal rates from a computer or controller accurately. The unit recognizes any signals below 2mA as signal interrupted and will automatically operate according to the preset mode. 9-3 Sensitivity volume and ZERO / SPAN adjustment * Resolution is preset at 1/250 (0.4%) before shipment. Noise disturbance on signals will unnecessarily and frequently drive the motor and will heavily shorten its life. In such a case, user may mitigate the influence of such disturbance by lowering sensitivity within an allowable range. Sensitivity volume * Clockwise for higher * Counter clockwise for lower (SW1) (SW2) * Max. resolution : About 1/300 Sensitivity volume (SW1) (SW2) SPAN volume ZERO volume FIG.12 FIG.13 * Min. resolution : About 1/100 ZERO volume * CW for higher Adjustable range : -25 to +25% SPAN volume * CW for wider Adjustable range : 50 to 200% Note : First adjust ZERO, then adjust SPAN. Note : ZERO / SPAN volume is pre-adjusted appropriately before shipment. Do not re-adjust it unless it is by all means necessary. For adjustment, use a trimmer driver within the torque range of 300g/cm. Avoid applying excessively large force, for it may cause troubles to the unit. -9-

Confirm that power is OFF before making manual operation 10. OPERATION 10-1 Manual operation Manual override shaft Allen key 1. Remove dust cover from the body and find a hexagon hole in the underneath.. 2. Insert lever handle into the hole to turn the shaft CW for downward, CCW for upward. Note : Do not apply excessively large force beyond the operation range, for it may cause troubles to the unit. FIG.14 Allen key hole Stroke Opposite 4mm 2mm /turn CAUTION When making manual operation, be sure that power is off. If power is on while manual operation, the lever handle will suddenly return! 10-2 Power operation 1. Before making power operation, confirm by manual operation that valve position is exactly matching with actuator at top / bottom limit positions. Note : Confirm that the shaft moves smoothly without eccentricity. 2. Confirm that the wiring is proper, also confirm with external signals that valve is normally positioned at top and bottom limits. 3. Start operation after confirmation is over. -10-

11. MAINTENANCE / INSPECTION Lubrication As the major parts of the products are lubricated with long life anti-corrosive grease before shipment, re-lubrication is in principle not required. Inspection When re-starting operation after a long period of rest, make the following confirmation. 1. Cut power off, confirm by manual operation that valve moves smoothly without eccentricity. 2. Open body cover and check if there is no condensation inside the unit, also no problem on wiring. Note : After checking, firmly screw up the covers to prevent water ingress. 12. TROUBLE SHOOTING TROUBLE AND PROBABLE CAUSE * MOTOR DOES NOT START UP Power is off Signal is off or below 2mA Circuits or terminal are open Supply voltage is improper or too low Limit switch is faulty Motor is defective or lead wire is broken Over capacity for motor advancer Load is insufficient for torque limiter function (Check if lamp lights) Wire connector is open * INPUT SIGNAL AND OPENING POSITION ARE NOT MATCHING EACH OTHER ZERO / SPAN adjustment is improper * MOTOR IS CONSTRAINED AT UPPER LIMIT Upper position limit switch is set out of range Limit switch is faulty * MOTOR IS CONSTRAINED AT LOWER LIMIT Setting rate for bottom torque limiter is too large Limit switch is faulty SOLUTION Supply power Check signal Renew cables or re-connect terminal Check terminal voltage with a tester Renew limit switch Renew actuator Replace advancer (condenser) Change the setting rate for torque limiter Insert connector (CN-1, 9-pin, white color) properly Re-adjust ZERO / SPAN volumes Re-adjust the switch Renew limit switch Change the setting rate for torque limiter Change limit switch * For other situation of troubles than the above, please refer to our Sales Dept. * For any special version, contact our Sales Dept -11-