71A D 400W 277V MH Ballast

Similar documents
MAGNETIC HID BALLASTS

HIGH INTENSITY DISCHARGE BALLASTS

Ballasts For High Intensity Discharge Lamps

CORE AND COIL, DRY CAPACITOR, BRACKET, IGNITOR, MOUNTING HARDWARE 3-15/16 INCH L X 2.13 INCH W X 2-3/16 INCH H

GECAP24400V0 Capacitor For 400W MH BLST

GE Ballast HID Electromagnetic nomenclature

Understanding Electronic UltraMax HID Ballasts

Understanding Electronic UltraMax HID Ballasts

ELECTROMAGNETIC HID BALLASTS

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

Ballasts For High Intensity Discharge Lamps

FDBT S 32W120V DM Bal

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

These new lamps have also yielded many different shapes and sizes of the ballasts, which are required for lamp operation.

fish ^^ ELECTROMAGNETIC BALLASTS TF 2-PIN COMPACT LAMPS IV I m PREHEAT BALLASTS Refer to pages for lead lengths and shipping data Lamp Data

HID Lamps Ballasts Magnetic Ballasts Electronic Ballasts Electronic Ballasts for Low Wattage Metal Halide

1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast

PGL350P W PS Wallpack

Standard Grade 14 Inch Reflector. Ordering Information

Applications. Standard Materials

Low Voltage Lighting Power Supplies

AFL FLOODLIGHT SERIES

GEM400ML5AA45 400W MH Core & Coil Ballast Multi Volt

Lighting Tables for New Equipment 7/16/2008

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast

and Refrigeration Institute). CNX Special Purpose Contactors

General Purpose Buck - Boost Wiring Diagrams... 86

ELECTRONIC HID BALLASTS

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

Lighting: Explosionproof Area HID. Applications. Standard Materials

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Specification for 400W Industrial Highbay Luminaire and lamp

KAD250MR3TBSPD04 Wall Fixture

Applications. Standard Materials. Certifications and Compliances

RELB2S40N35I (2)F40T12 120V Ele BLST

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

LINEAR LED. Delivering Quality Light Better LOW BAY HIGH BAY WET LOCATION EDGE LIT PANELS 2' HIGH BAY NOW IN STOCK INTRODUCING

Replacement. Metal Halide CR2000. Product Wattage CCT Total Lumen Efficacy Voltage Frequency Base Installation Angle

Overall Dimensions. Specifications

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

50 Series. Features. Suffix Suffix Series Voltage Combinations

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

TAG-DR Series. Indoor or Outdoor LED Driver Box - TAG LED Flood Solutions. Specifications. Overall Dimensions For Reference Only TAG-DR

Three Phase Transformers

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

Linear Fluorescent Highbays. A comprehensive selection of high output commercial/industrial fluorescent lighting

DELIVERING QUALITY LIGHT BETTER. Linear LED LOW BAY HIGH BAY WET LOCATION

Ballasts For High Intensity Discharge Lamps

TORNADOTM BOLLARD PATENTS PENDING

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Ballasts For High Intensity Discharge Lamps

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Installation Instructions

Applications. Standard Materials. Certifications and Compliances

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Ballasts For High Intensity Discharge Lamps

Applications. Illustrated Features

ELECTRONIC FLUORESCENT BALLASTS

ORDERING INFORMATION: 120 Volts (120)

Constant wattage for high intensity discharge (HID) lamps

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

PH250MQMJ CNTL 250VA 240X X240

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

HPS Imperator Machine Tool Industrial Control Transformer

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

SXPJ SERIES S X azz.com/rigalite

Morris Products 53 Carey Road, Queensbury, NY 12804

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP051A0712

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

TCPHB4UNI1250K10 4' 12, 000 Lumen Unv Volt Led High Bay 5000K

Compact SE Overview. High-Performance Dimming. Ballast

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

ELECTRONIC FLUORESCENT BALLASTS

LED LINEAR QUICK SUMMARY CO W SI MODEL CORTANA

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

CRYSTALGLO. Holophane s potted ballast provides good thermal dissipation and sound absorption, for long life and quiet operation.

TA Ta VA CTRL-XFRMR

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

PGA Parking Garage Luminaire

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

N2MV Series W Non-metallic

ER D IN K F IC U ST Q LLA BA

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

Champ MLL LED luminaires

Transcription:

3804 South Street 75964-7263, TX acogdoches Phone: 936-569-7941 Fax: 936-560-4685 716031500 400W 277V MH allast Philips dvance Catalog umber 716031500 Manufacturer Philips dvance escription allast, Contents allast, ry Film Capacitor; Voltage 277 V; Current 1.7 mpere; Power 458 W; 60 HZ; Metal Halide Lamp; 400 W Lamp Wattage; Constant Wattage utotransformer ; nsi Code M59/H33 Weight per unit 12.4 (lbs/each) Product Category 19980601100835 Features SI Code Type Contents Current Power Voltage Lamp Type Lamp Wattage Minimum Starting Temperature imensions and Weight Size escriptions dditional Information Commodity escription Long escription Manufacturer Information rand Manufacturers Part umber Model M59/H33 COSTT WTTG UTOTRSFORMR LLST, RY FILM CPCITOR 1.7 MPR 458 W 277 V MTL HLI 400 W -20 G F 4 3/4 ICH L X 3.8 ICH W X 4 1/4 ICH H 4 1/4 ICH X 4 3/4 ICH COR allasts - High Intensity ischarge allasts & ccessories LLST, COTTS LLST, RY FILM CPCITOR; IPUT VOLTG 277 V; IPUT CURRT 1.7 MPR; IPUT POWR 458 W; 60 HZ; MTL HLI LMP; 400 W LMP WTTG; COSTT WTTG UTOTRSFORMR CIRCUIT; SI CO M59/H33 dvance 716031500 71

3804 South Street 75964-7263, TX acogdoches Phone: 936-569-7941 Fax: 936-560-4685 vailability Status Inactive Packaging Carton 1 Package 4 Weight Per each 12.38 Uses, Certifications, and Standards pproval UL 1029, CS 22.2 Frequency Rating 60 HZ

HIGH ITSITY ISCHRG LLSTS Core & Coil allasts (60 Hz., Minimum Starting Temperature 20 F or 30 C) HI Volts Catalog umber Type Watts Current 400 Watt Lamp, SI Code M59 or H33 277 716037-716037-001 120 277 480 480/120T 716001 716031 716041 716041-001 716041-T Linear Reactor HPF CW 458 CW CW om Open Voltage Fuse Rating (mps) Wiring ia Fig imensions Mfd on-pc Capacitor (Page 4-48 to 4-49) Min Volt Cap Catalog umber ry or Oil Total Weight (Ibs) 425 2.1 277 5 H 10 1.6 3.8 20 7C200P33-R 9.0 462 462 4.0 1.7 1.0 1.0 10 5 4 4 2 2 2 3.8 3.8 24 400 7C240P40-R 11.5 11.5 Metal Halide Ignitor (Page 4-50 to 4-53) Part umber Integral Ignitor ist To Lamp (ft) U.L. ench Top Rise Code 1029 (pg 4-3) 2 277 716081 CW 458 4.0/1.7 5 2 3.9 24 400 7C240P40-R 11.5 / 127/220 7160H1 CW 458 3.9/2.2 7 2 3.8 24 400 7C240P40-R 11.5 4.0 4.0 24 24 400 400 7C240P40-R 7C240P40-R 1 1 ew 240/277 716091 CW 458 4.0/2.3/ /1.7 240/277 716091-* CW 458 4.0/2.3/ /1.7 240/277/ 480 716051 4.1/2.3/ 716051-001 CW 460 /1.7/ 1.0 240/277 716071-001 CW 458 4.0/2.3/ /1.7 277/347 71601 CW 460 4.0/ 1.7/1.4 277/347 71601-* CW 460 4.0/ 1.7/1.4 277/347 71601-001 CW 460 4.0/ 1.7/1.4 208/240 71606 CWI 465 4.2/ 2.5/2.1 7/ 5/5 7/ 5/5 7/ 5/5/ 3 7/ 5/5 5/4 5/4 5/4 320 7/5 Ordering information: Replacement/retrofit ballast kits indicated by bold type with suffix -001 or -001. 716037-001 kit also includes welded angle bracket.refer to pages 5-5 to 5-9. Original equipment ballasts - add proper suffix to catalog number: -500 includes core & coil with dry-film capacitor -510 includes core & coil with welded bracket and dry-film capacitor -540 includes core & coil with welded angle bracket and dryfilm capacitor. (vailable for 716037- only) -500 includes core & coil with oil-filled capacitor -510 includes core & coil with welded bracket and oil-filled capacitor -600 core & coil only (no capacitor) -610 core & coil with welded bracket (no capacitor) For CW and CWI circuits, figure is operating current. For Linear Reactor circuits, figure is highest of starting, operating, or open circuit currents. Canadian replacement/retrofit ballast kit indicated by bold type. Refer to page 5-10. * Includes copper primary/aluminum secondary coils. P 3.31 2 3.9 24 400 7C240P40-R 11.5 / / 2 2.2 4.0 24 400 7C240P40-R 11.5 / / 2 2.2 4.0 24 400 7C240P40-R 14.0 /C/ /C/ 2 2.2 4.0 24 400 7C240P40-R 11.5 / / / 2 4.0 24 400 7C240P40-R 1 2 2.4 4.0 24 400 7C240P40-R 1 2 2.4 4.0 24 400 7C240P40-R 1 2 2.4 4.0 20 425 M2006-100 O 14.0 277/347 7160F6 CWI 462 1.8/1.4 325 5/3 P 2 2.4 4.0 20 425 M2006-100 O 14.0 racket etail (Fig. 10) Suffix-510 provides welded-on mounting foot bracket. 4 Holes cleared for #10 thru-bolts MX. 3.75 4 Holes cleared for #6 thru-bolts 4.06 4.50 Fig. 10 (4 1 /2" x 3 3 /4 Reactor Core ) Suffix-540 provides welded angle bracket to allow specific Linear Reactor ballasts to mount in 400-watt fixtures designed for standard CW ballasts without brackets (Figure 2). WL RCKT IMSIOS allast imensions Fig L W M S 2, 10 6.5 1.25 5.75 0.28 3 7.8 2.75 6.13.25 / / HI COR & COIL MTL HLI VC, 10275 WST HIGGIS RO, ROSMOT, IL 60018. TL: (847) 390-5000, FX: (847) 390-5109 5-27

HIGH ITSITY ISCHRG LLSTS ncapsulated Core & Coil Where quiet performance is required, the standard open core & coil ballasts are encapsulated (potted) in a cube-shaped steel can utilizing Class H (180 C) polyester compound. These ballasts carry a Class noise rating up through 175 watts and Class for 250 and 400 watts. s with the open core & coil, the capacitor (and ignitor where included) are mounted separately within the fixture. Fluorescent Can (F-Can) For indoor commercial applications of HI lighting such as offices, schools and retail stores, ballast noise must be minimized. allasts for these fixtures are most often encased and potted in fluorescent ballast type cans and utilize Class (90 C) asphalt insulating materials (the same as used in fluorescent lamp ballasts). The dvance line of F-can ballasts comes in two dual-voltage configurations: 277 volt for the US market, and 347 volt for the Canadian market. ach unit has built-in, automatically resetting, thermal protectors which disconnect the ballast from the power line in the event of overheating. ll units are high power factor and include the capacitor within the can. ll models for high pressure sodium, lowwattage metal halide, and pulse-start metal halide lamps also include the ignitor in the can. Indoor nclosed These units are designed for use indoors where the ballast must be mounted remotely from the luminaire. They are most typically used in factories where the luminaire may be mounted in a high-bay where very high ambient temperatures may be experienced. In these instances, the remotely-mounted ballast operates cooler, subsequently providing longer life because it is away from both the heat of the ceiling ambient and lamp heat within the fixture. The case contains the core & coil potted in a Class H (180 C) heatdissipating resin. The capacitor(s) and ignitor are contained within a separate compartment. Knockouts in both ends of the case facilitate hook-up in the most convenient manner. Wall mounting is accomplished through flanges on the top and bottom of the case. The ballast is a UL Listed product. Outdoor Weatherproof Weatherproof ballasts are designed for remote, pole-mounting outdoor applications under all weather conditions. They may also be placed inside of a transformer pole base, but care must be taken to avoid areas prone to flooding because weatherproof ballasts are not water-submersible. The core & coil with its capacitor and ignitor (where required) are firmly mounted to the heat-sink base. n aluminum cover is placed over the core-&-coil assembly and is bolted with a weather-tight gasket to the base. n integral 1" threaded nipple with locknut facilities hook-up to electrical conduit or to the mounting bracket when used on a pole. The weatherproof ballast may also be placed nipple-up, with a drip loop in the leads, inside a pole base. Postline Lantern-type fixtures mounted on slender poles often require ballasts which will fit into these poles. Special, elongated core & coil ballasts are potted in resin in cylindrical cans having a 2.55 outside diameter. ll include leads necessary for direct connection to a photocell. The capacitor and ignitor (where required) are included within this can. ¹ ₂" threaded nipple is used for vertical mounting, and leads extend from both ends of the can for ease of installation. The input leads to the ballast also provide for proper connection to the photocell if such is included within the fixture. To help prevent overheating, one to three feet of air space should be allowed in the pole above the ballast, and the ballast should be positioned against the post interior wall to provide a heat-sink. ll units rated 100W and above now include a mounting kit consisting of an 18" chain to hang the ballast within the pole and a spring clip to force the ballast's cylindrical can to make line contact with the pole's interior surface to maximize heat transfer, thus prolonging the ballast life. LLST T TMPRTUR COS allast Label lternate Positions for ate Stamp Code Catalog umber Temperature Code ate Code Stamp VC HI Core & Coil ballasts are date stamped on either the top surface or the side surface of the ballast core. The four-digit number represents the week and year of manufacture. The first two numbers indicate the week and the last two indicate the year the ballast was manufactured. The example shows a ballast manufactured during the 36th week of 1989. The three letters are an dvance factory code. The ballast s UL ench Top Rise Temperature Code is shown on the label (see below). UL CH TOP RIS TMPRTUR CO To facilitate UL inspection, each ballast s UL ench Top Rise Temperature Code is shown on the dvance Core & Coil ballast label as 1029X, where 1029 is the UL Standard for HI allasts, and the X is the temperature code:,, C, etc. If a fixture is UL listed for 1029C, then automatically, all ballasts with an,, or C temperature classification are acceptable for use within that same fixture. UL ench Top Rise Letter Code C F etc. Temperature Range for Class H (180 C) allasts less than 75 C 75 C < 80 C 80 C < 85 C 85 C < 90 C 90 C < 95 C 95 C < 100 C etc. Temperature Range for Class (200 C) allasts less than 95 C 95 C < 100 C 100 C < 105 C 105 C < 110 C 110 C < 115 C 115 C < 120 C CRTIFICTIOS Indicates ballast is listed by Underwriters Laboratories, Inc. in accordance with UL 1029 Standard for HI allasts. ach ballast is marked appropriately. Indicates ballast is component recognized by Underwriters Laboratories, Inc. in accordance with UL 1029 Standard for HI allasts. ach ballast is marked appropriately. Indicates ballast is certified by Canadian Standards ssociation in accordance with C/CS-22.2 o. 74-92.ach ballast is marked appropriately. ll HI allasts are designed and manufactured in accordance with the merican ational Standards Institute Standard for HI allasts, SI C82.4. etc. HI VC, 10275 WST HIGGIS RO, ROSMOT, IL 60018. TL: (847) 390-5000, FX: (847) 390-5109 5-3

HIGH ITSITY ISCHRG LLSTS ORRIG IFORMTIO How to Order dvance Transformer has developed the industry s broadest selection of HI ballasts. More than 0 stocking distributors nationwide. For information on the distributor best able to serve your needs, please call 800-372-3331. dvance HI allast Part umber xplanation 71 60 9 1-500 Suffix Code* (as applicable) -001 ballast replacement kit with dry capacitor and integral ignitor -001 ballast replacement kit with dry film capacitor -001 ballast replacement kit with oil filled capacitor -500 core & coil ballast with dry film capacitor -500 core & coil ballast with oil filled capacitor -510 core & coil ballast with welded bracket and dry film capacitor -510 core & coil ballast with welded bracket and oil filled capacitor -540 core & coil ballast with welded angle bracket and dry film capacitor -600 core & coil ballast (no capacitor) -610 core & coil ballast with welded bracket (no capacitor) * dd additional feature codes to the end of suffix where applicable. i.e. - = Integral Ignitor, -P = Thermally Protected, -J = J-ox Mounting esign Code IPUT VOLTG CO 60 Hz Voltages 50 Hz Voltages 0 = 120V = 277/347V M = 100/200V 1 = 208V = 347V = 220-240V 2 = 240V C = 347V R = 220/240V 3 = 277V = 240/347V 4 = 480V = 240V or 208/240V 5 = 240V or F = 277/480V, 277/347V, 277/347/480V or 240/277/480V 347/480V 6 = 240/480V H = 127/220V 7 = 240/277V J = 220V or 220/240V 8 = 277V Y = 100V or 100/200V 9 = 240/277V HI Lamp Type/Wattage/allast Code allast Type 71 = Core and Coil allast 72C = F-Can allast 73 = ncapsulated Core and Coil allast 74P = Postline allast 77K = Val-U-Pak Replacement allast Kit 77L = Val-U-Pak Plus Replacement allast kit (includes lamp) 78 = Indoor nclosed allast 79W = Outdoor Weatherproof allast VC, 10275 WST HIGGIS RO, ROSMOT, IL 60018. TL: (847) 390-5000, FX: (847) 390-5109 5-13

HIGH ITSITY ISCHRG LLSTS Core & Coil allasts (60 Hz., Minimum Starting Temperature 20 F or 30 C) HI ew ew ew ew Volts 208/240 277/ 347/480 277/ 347/480/ 120T 240/277 347/480/ 120T 208/240 277/ 347/480 Catalog umber 71642 7164F2 7164F2-T Type CW CW CW Watts Current Cap Catalog umber 7.0/ 20/ 812 355 M 8 2.2 4.3 28 400 7C280S40 17.0 LI573-H5 15 4.0/3.5 10 3.0/ 8/ 818 355 M 8 2.3 4.3 28 400 7C280S40 17.0 LI573-H5 15 2.5/1.7 7/5 3.0/ 8/ 818 355 M 8 2.3 4.3 28 400 7C280S40 17.0 LI573-H5 15 2.5/1.7 7/5 71865 CW 850 7.2/ 20/ 235 4.1/3.6 10 M 8a 3.2 5.3 75 280 7C280S28R 25.0 LI561-H5 5 7186F5 CW 850 3.1/ 235 2.5/1.8 5 M 8a 3.2 5.1 75 280 7C750S28R 25.0 LI561-H5 5 875 Watt Lamp, SI Code Unassigned (Venture pulse-start lamp) 716498 240/277 CW 347/480/ 7164F8-T 120T CW om Open Voltage 750 Watt Lamp, SI Code M149 (Pulse-Start) 716490 7164F0-T CW CW Fuse Rating (mps) Wiring ia imensions Fig Mfd on-pc Capacitor (Page 5-48 to 5-49) 7.8/4.3 20/ 940 415 M 2 3.0 5.0 21 480 3.9/3.4 M2100-030 O 17.5 LI572-H5 5 8 Min Volt ry or Oil Total Weight (Ibs) Metal Halide Ignitor (Page 5-50 to 5-53) Part umber 7.0/4.0/ 20/ 820 340 M 2 3.0 4.9 28 400 7C280S40 17.5 LI573-H5 10 3.5/3.0 10 ist To Lamp (ft) 820 2.5/1.7 340 7/5 M 2 3.0 4.9 28 400 7C280S40 17.5 LI573-H5 10 750 Watt Lamp, Retrofit for 750 Watt HPS, SI Code S111 (Pulse-Start) 945 2.8/ 415 7/5 M 2 3.0 5.0 21 480 M2100-030 O 17.5 LI572-H5 5 U.L. ench Top Rise Code 1029 (Pg 5-3) VC Class H Class (180 C) (200 C) / C/ / / C/C / / / / / / / / / / / / / // / / Ordering information: Original equipment ballasts - add proper suffix to catalog number: -500 includes core & coil with dry-film capacitor -510 includes core & coil with welded bracket and dry-film capacitor -500 includes core & coil with oil-filled capacitor -510 includes core & coil with welded bracket and oil-filled capacitor -600 includes core & coil only (no capacitor) -610 includes core & coil with welded bracket (no capacitor) For CW circuits, figure is operating current. quipped with an auto-reset thermal protector to prevent ignitor from overheating in the event of lamp failure. ach ballast requiring an ignitor is furnished as standard with the Short Range ignitor model shown for use within fixtures. If a Long Range ignitor is required for remote mounting, specify on order. See pages 5-50 to 5-53 for additional information. ual rated Class H (180 C) / VC Class (200 C) insulation system. Refer to page 5-3 for additional information. Special Compact 4-1/4 x 4-3/4 core design 3.31 MX. 4.06 3.75 44 Holes Holes cleared cleared for for #10 #6 thru-bolts 4.50 Fig. 10 (4 1 /2" x 3 3 /4 Reactor Core ) Suffix-510 provides welded-on mounting foot bracket. 3 7 /8" MX. 3 7 /8" 4 1 /4" MX. Suffix-540 provides welded angle bracket to allow specific Linear Reactor ballasts to mount in 400-watt fixtures designed for standard CW ballasts without brackets (Figure 2). racket etail (Fig. 10) 5 3 /8" 4 3 /8" 4 3 /4" 4 3 /8" 5 3 /4" 4 1 /4" 44 Holes Holes cleared cleared for for #10 #10 thru-bolts Fig. 2 (4¹ ₄ Fig. x 4³ ₄ 2 core) (4 1 /4" x 4 3 /4" core) 8 Holes cleared for #10 thru-bolts 1 1 /4" Fig. 3 (4 1 /4" x 5 3 /4" core) WL RCKT IMSIOS allast imensions Fig MX. 3 7 /8" 4 1 /4" 4 3 /8" 5 3 /8" 6 " Fig 8, 8 Fig. 8 (4 1 /4" x 6" core) L W M S 2, 10 6.5 1.25 5.75 0.28 3, 8 7.8 2.75 6.13 0.25 8a 7.8 4.50 6.75 0.31 8 Holes cleared for #10 thru-bolts (4 1 /4 x 6 core) HI COR & COIL MTL HLI VC, 10275 WST HIGGIS RO, ROSMOT, IL 60018. TL: (847) 390-5000, FX: (847) 390-5109 5-29