Control valves with electric actuators up to 90 C PN

Similar documents
CV 206/216/306/316 GG. Standard control valves 2- or 3-way, DN , cast iron

Control valves with pneumatic actuators up to 350 C PN

Control shut-off butterfly valves DN 25 DN 200 PN

Control shut-off butterfly valves DN 25 DN 200 PN

Control shut-off butterfly valves DN 50 DN 350 PN

EL5600 Series Electric Actuators for DN15 to DN100 Valves

3-port seat valves, external thread, PN16

Modulating control valves with magnetic actuators, PN 16

3-Port Seat Valves with Male Thread, PN 16

AEL5 Series Electric Linear Actuators for DN15 to DN100 Control Valves

VE VVG Series Electronic Two-way Valves Normally Closed

3-Port Seat Valves with Male Thread, PN 16

Modulating control valve PN16 with magnetic actuator

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

3/2-Way Motor Valve compact 7280

ARI-STEVI 440 / 441 DVGW type approval

ARI-ZESA / ARI-GESA / THEA Butterfly valves

V5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve

Two-port seat valves with male thread, PN16

3-way control valve in mixing and diverting design

Modulating control valve PN16 with magnetic actuator

LINEAR ELECTRIC ACTUATORS

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

Modulating control valves with magnetic actuators, PN 16

ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. Electric thrust actuator ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. ARI-PACO 2G 1,6 D 1,6 kn

VG7000 Female Threaded Cast Bronze Valve Series with Electric Actuators

Butterfly valves ARI-ZIVA -Z / ARI-ZIVA -G. with notch lever. with worm gear. with electric rotary actuator rotork

Valve Body Material:Ductile iron QT Caliber:DN50...DN250 Standard of flange connection in accordance with ISO7005-2

2-Way & 3-Way Non Spring Return Characterized Ball Valves

Butterfly valves. ARI-ZIVA -Z - Fig Free of maintenance wafer pattern butterfly valve - soft sealed - industrial range

Mark 37/377 Series. Control Valves Mark 37/377 Final Control Element. Final Control Element. Features

Page 6. Page 6. Page 6. Page 7. Page 8. Page 9. Page 10 / 11

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

High Pressure 2-way 2 1/2-6 Globe Valves

VG6000 Series Forged Brass Valves

VG9000 Flanged Valves

---Pressure Independent Control Valve

Motor Valve compact 8230

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

3-port seat valves PN16 with flanged connection

AEL6 Series Smart Electric Actuators for ½" to 4" Control Valves

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Modulating control valve PN16

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

Electronic Globe Valves

with electric and pneumatic actuators Control valve in 3-way-form (3-way mixing valve) DN 300 ARI-STEVI 423 Electric actuator ARI-PREMIO

Motor Valve GS 1 series, DN 15 up to DN 150

LINEAR ELECTRIC ACTUATORS

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Modulating control valves with magnetic actuator PN 16

V5049A FLANGED LINEAR VALVE PN25/40

Valves and Actuators

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

STEVI 450 / way control valve in mixing and diverting design DN

NV Direct Coupled Globe Valve Actuator

FAIL-SAFE CONTROL VALVES. Fast Electrically Actuated Control Valves

2-port and 3-port valves with T-bypass PN 16

STEVI 440 / 441. Straight through control valve DN

3-way 1/2-2 Globe Valves

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Electric linear actuators

Features Globe Valve 2-Way & 3-Way Assembly Features:

AEL6 Series Smart Electric Actuators for DN15 to DN100 Control Valves

VPA Series and VAP Actuator

STEVI 440 / 441. Straight through control valve DN

Modulating control valve with magnetic actuator PN16

3/2-Way Motor Control Valve 7382 DN 15 up to DN 50

Product overview linear actuators SBA

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

ADCA VALSTEAM ADCA. LINEAR ELECTRIC ACTUATORS Type EL EL12, EL20, EL45, EL80, EL120, EL250 DESCRIPTION

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

Modulating control valves with magnetic actuator PN 16

Mark 33 Series. Control Valves Mark 33/39 Electric Motor Control Valves. Electric Motor Control Valves. Features. CRN Registration Number Available

with electric actuators Feedwater control valve with pump spill back DN

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Flanged Motor Valve compact DN 15 up to DN

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

3-Port Seat Valves with Flange, PN 6

TAC TM Butterfly Valve Assemblies

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

ARI-STEVI 450 / 451 Pneumatic actuator ARI-DP 32-34T. Electric actuator ARI-PREMIO 2,2-25 kn ARI-PREMIO-Plus 2G 2,2-25 kn

3-Port Seat Valves with Flange, PN 10

Combi valves PN 16 with flanged connections

ARI-STEVI 423 / 463 (DN ) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

Modulating Control Valve PN 16 with Magnetic Actuator

Motorized Segmented disc valves 5030 DN 25 bis DN 300

MXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products

ARI-STEVI 423 / 463 Pneumatic actuator ARI-DP 34-34T. Electric actuator ARI-PREMIO 5-25 kn ARI-PREMIO-Plus 2G 5-25 kn

ARI-STEVI 470 / 471 (DN15-150)

2-port and 3-port terminal unit valves PN16

3-port seat valves PN16 with flanged connection

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Transcription:

Features Suitable for the control of hot and chilled water (0...+90 C) in drinking water systems Valves with DVGW test mark reg. no. DW-6340BP0198 acc. latest German Drinking Water Ordinance (TrinkwV 2001) Tight shut-off in the closed position Microprocessor controlled Automatic self-calibration on start up Technical data valve Series Form Two-way Three-way Diameter nominal DN 15 + DN 20 DN 25 DN 50 DN 15 + DN 20 DN 25 DN 50 Pressure rating A AB equal % Characteristic A AB equal % B AB linear Stroke mm 12 14 12 14 Rangeability DN 15: 50:1 DN 20 50: 100:1 DN 15: 50:1 DN 20 50: 100:1 Function: Connection type: Leakage rate: as two-way valve as mixing or on-off valve Body with external thread acc. ISO 228/1 incl. connection parts of bronze with cylindrical internal thread acc. ISO 7/1, union nuts and gaskets EN 1349 seat-leakage VI G 1 (tight sealing) Body: CC491K Plug: CrNi-steel 1.4305 Stem: CrNi-steel 1.4571 Stem sealing: O-rings EPDM Internal thread connection parts: CC491K Union nut: Malleable cast iron GTW Valve variant Technical silicon free version 1/6

Drawing Technical data actuator MC100 / MC160 Type MC100/24 MC100/230 Actuating time 1) s/mm 12 9* 4 1.9 12 9* 4 1.9 Actuating thrust kn 1.0 1.0 Stroke mm max. 20 max. 20 Power supply VAC 24 10% 230 +6% -10% Power supply 2) VDC 24 10% - Frequency Hz 50/60 5% 50/60 5% Power consumption VA 6 12 Input signal 3) Output signal 3) 0...10 VDC max. 8 ma 0...10 VDC max. 8 ma Hysterisis 4) V 0.15 0.5 0.15 0.5 1) Actuating time freely adjustable, presetting is marked with * 2) only retified alternating voltage 3) Invertible input and output signal 4) Freely adjustable 2/6

Type MC161/24 MC161/230 Actuating time 1) s/mm 6 4* 6 4* Actuating thrust kn 1.6 1.6 Stroke mm max. 20 max. 20 Power supply VAC 24 10% 230 +6% -10% Power supply 2) VDC 24 10% - Frequency Hz 50/60 5% 50/60 5% Power consumption VA 6 12 Input signal 3) Output signal 3) 0...10 VDC max. 8 ma 0...10 VDC max. 8 ma Hysterisis 4) V 0.05 0.15 0.3 0.5 0.05 0.15 0.3 0.5 Enclosure protection: IP 54 Resolution: MC electric 0.04 VDC MC100 mechanical 0.095 mm MC161 mechanical 0.05 mm Operating mode: S3-50% ED c/h 1200 EN 60034-1 End position switch-off: Ambient temperature: load-dependent 0...+60 C Weight: MC100 2.5 kg MC161 3.2 kg Actuator variant and accessories Voltage: Position switch unit 5) : Enclosure protection: IP 65 Board for output signal X=0(4)...20 ma 5) Adapter with coupling for external products 115 VAC 2 switches (WE1/WE2), potential free, infinitely adjustable Rated load: 8 A / 250 VAC 8 A / 30 VDC Turn-on voltage: max. 400 VAC max. 125 VDC 1) Actuating time freely adjustable, presetting is marked with * 2) only retified alternating voltage 3) Invertible input and output signal 4) Freely adjustable 5) Position switch unit and output signal 0(4)...20 ma not in combination 3/6

Circuit diagram B1/B2 Connection of a binary signal (e.g. frost safety) Technical data valve with actuator DN 15 20 25 32 40 50 kvs-value m³/h 4 2.5 1.6 1.25 0.63 6.3 5 10 8 16 12.5 Stroke mm 12 14 145 170 25 20 40 31.5 MC100/24 MC100/230 Actuating time 1) s 105 125 45 55 20* 30* Closing pressure kpa 1600 1600 1600 1500 900 550 350 MC161/24 MC161/230 Actuating time 1) 100 kpa = 1 bar = 10 mws s Closing pressure kpa 1500 950 600 1) Actuating time freely adjustable, presetting is marked with * 95 55* 4/6

Drawing MC100 MC100 MC161 MC161 Installation instruction: Valve trim could be damaged by dirt in the pipe system. Therefore we recommend the installation of strainers. 5/6

Dimension DN 15 20 25 32 40 50 G Rp ½ Rp ¾ Rp 1 Rp 1 ¼ Rp 1 ½ Rp 2 L mm 62 75 80 120 130 150 L 1 mm 114 127 138 184 198 222 B mm 40 41 45 55 60 65 B 1 mm 66 67 74 89 94 101 B 2 mm 48 53 57 68 73 78 G 2 G 1 A G 1 ¼ A G 1 ½ A G 2 A G 2 ¼ A G 2 ¾ A SW mm 37 48 53 68 73 88 T mm 13 15 17 19 19 24 H MC100 24 VAC mm 338 341 344 353 358 358 230 VAC mm 363 366 369 378 383 383 MC161 24 VAC mm 420 423 423 230 VAC mm 445 448 448 m MC100 kg 3.4 3.9 4.2 5.9 6.5 8.1 MC161 kg 6.6 7.2 8.8 6/6