NetSure. 211 Series DC Power System

Similar documents
NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)

VERTIV XTE 401 SERIES. Ordering Guide

Liebert. APS UPS 5-20 kva Flexible, efficient scalable UPS for room or row-based applications

CPS2000 Cabinet Power System

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version)

3 Uninterruptible Power Systems

Sola/Hevi-Duty S3K Series Mini-Tower UPS

and other -48VDC Power Systems. 19 or 23 Wide (Nominal) Relay Rack (part of system).

Liebert PowerSure PSI UPS

Keatec Energy Catalogue 2018 Telecommunications

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

596 Rectifier Retrofit

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual

NETXTEND FLEX SERIES Equipment Enclosures

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

3 Uninterruptible Power Systems

Uninterruptible Power Systems

PowerValue 11/31 T kva

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

NetSure. V200D50 DC Power Retrofit. Installation and User Manual (UM ), Revision F. Specification Number: Model Number: V200D50

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

The Power of Reliability INSTRUCTION MANUAL

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Uninterruptible Power Systems

Liebert. PSI & PSI-XR 750VA - 3kVA & 1kVA-3kVA High Performance Power Protection for Servers and Networking Equipment

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

EFFEKTA Power Supplies

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

ABB central inverters ULTRA-750/1100/ kW to 1560kW

A36D CONTROLLED FERRORESONANT RECTIFIER / POWER SUPPLY BATTERY CHARGER / POWER SUPPLY. Standard Features

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

TLE Series UPS 400/500 kw With eboost Technology

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

3 Uninterruptible Power Systems

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

TLE Series UPS 160/200/225/250 kw with eboost Technology

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical data sheets

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT

POWER kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TLE Series UPS 750/1000 kw With eboost Technology

POWER kva

AT30 SERIES BATTERY CHARGER

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Sola 3000 Guide Specifications

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

NetSure. DC/DC Converter Module. User Manual (UM1C e / 11XA9076RJ), Revision G. Specification Number: 1C e Model Number: C400/ e

DP140e. Installation & Operations Manual

Uninterruptible Power Supply

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

3 Uninterruptible Power Systems

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Power+ CLASSIC. 20/30 kva, 3x208 Vac

TECHNICAL DATA SHEET KVA UPS Systemss

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Liebert. EXM UPS kva/kw Efficient, Scalable, Intelligent Power Optimized for Midsize IT

Up to 98% efficient under full load Similar runtimes to the previous 3u model

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Technical Specification SENTINEL PRO

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Liebert. EXM UPS kva/kw Efficient, Scalable, Intelligent Power Optimized for Midsize IT

200 kva* Noise level (Generator online) Fuel tank size (approx. 5.5 hours autonomy) 1400 liters 308 gallons /370 US gallons

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

L kw Distributed Energy Storage System Unit (SU50)

Electric Power Marketing Spec Sheet Continuous Power Module CPM250

Three Phase UPS Systems Range: 10 to 500kVA

Installation and Operations Manual

Innovative Circuit Technology Ltd.

GENCORE 5 FUEL CELL SYSTEM System Fundamentals

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Liebert. GXT4 700VA - 3kVA Fully Digital Dual DSP Controlled UPS

SecureUPS On-Line 120V AC Output, 1300VA

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

esure Rectifiers and NetSure DC Power Systems Krunoslav Štibi May 30thth, 2012

Technical Data Sheets

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Transcription:

NetSure 211 Series DC Power System

NetSure 211 SERIES KEY FEATURES ysupports Ethernet, SNMP V2 & SNMP V3, ModBus and RS485 communication interfaces enables remote control and monitoring ynetsure rectifiers are designed to operate from -40 C to +75 C, providing 600 W output at 65 C suitable for harsh environmental conditions yextremely wide AC voltage range window 85 VAC to 300 VAC yseveral distribution configuration options battery disconnect breakers, load breakers, and GMT fuses up to 15 A to meet application needs ynebs Level 3 compliant and UL Listed to meet industry standards Description The NetSure 211 DC Power Solution is a flexible system capable of providing DC power through the use of 500 W or 1000 W rectifiers and a variety of output distribution options. The system is available in an integrated distribution configuration. The NetSure 211 is available in both 19" and 23" 1 RU & 2 RU rack-mount configurations, suited for up to 6 kw power requirements in the most harsh environments. The system is supported by a single SCU+, ACU+ or NCU controller (ACU+ for 2 RU systems only) that provides all control and operational conditions, as well as historical site data and external signal conditioning and monitoring. Each rectifier shelf includes a slot for the controller and space for the rectifiers. Distribution is provided by breakers or fuses located in the power shelf. Distribution options include load low-voltage disconnect (LLVD), battery low-voltage disconnect (BLVD), or no low-voltage disconnect. Plug-in rectifiers, AC connectivity and DC load outputs enhance the overall flexibility of the system by minimizing installation and start-up time. This dynamic system also offers alternative AC input configurations, relay rack configurations, battery tray options, battery box options and pre-configured output load kits. The NetSure 211 is designed for up to 4 kw loads (19") or 6 kw loads (23"). This cost-effective solution is NEBS Level 3 compliant and UL Listed. Rated for continuous operation from -40 C to +75 C (see rectifier data for derating), this system is designed for the harsh outside plant environment, as well as customer premise FTTx, wireless back-haul, microwave, and DLC applications. ymonitoring and battery test and charge functions advanced battery management features and AC service monitoring yconfiguration file capability minimizes installation time and allows planned network conformity 2

The NetSure 211 is especially designed for all types of access applications in both fixed and wireless access networks, offering unmatched site installation flexibility. Environmental Endurance Great output power at high temperatures NetSure 211 rectifiers deliver high output power in relation to ambient temperature conditions (see diagram 1), making them especially suitable for high-temperature environments. In a system with rectifiers operating at 65 C, the output is still 60% of full power. Extremely wide AC voltage range window The AC voltage input range vs. rectifier output is another extraordinary feature of this small system. The 1000 W rectifier will deliver full power from 176 VAC to 300 VAC. From 85 VAC to 176 VAC the power level is derated (see diagram 2). The 500 W rectifier will deliver full power from 104 VAC to 300 VAC. Configurability for Space and Energy Efficiency NetSure 211 comes in many different shapes This highly flexible DC power system, featuring efficiency levels greater than 92%, is available in 1 RU or 2 RU integrated distribution shelves. These alternatives are optimal for rack-mounting in any building, shelter or cabinet installation. NetSure 211 is easily integrated into any Vertiv outdoor enclosure when a pre-manufactured space-efficient outdoor solution is needed. The system can also be shipped loose or mounted in a relay rack with battery trays. Application The NetSure 211 System is designed for deployment in central office, POP sites, co-location sites, customer premises, outdoor cabinets, CEVs, vaults or portable shelters. Specific applications include: DLC, xdsl, DSLAM, FTTx electronics, broadband communications, multiplexers, LTE, WiMAX, microwave and PBX. Diagram1: R48-1000 Output Power vs. Temperature at 264V > Vin >176Vac % of output power 120 100 80 60 40 20 0-40 -20 0 20 40 60 80 100 For R48-1000 Temperature ( C) % of output power Diagram2: Output Power vs. Input Voltage at Tamb <45 C Output Power vs. Input Voltage and Vo > 48V at Tamb >45 C 120 100 80 60 40 20 0 0 50 100 150 200 250 300 350 For R48-1000 Input voltage (VAC) 3

NetSure 211 SERIES The NetSure 211 s extensive battery management capabilities, easy configuration and maintenance are all backed by the resources and quality reputation of a worldwide service organization. Basic Configurations Two core configurations define the combination of rectifier and distribution shelves and determine the ultimate capacity of the system. Internal Distribution up to 3 kw Our most compact system measures 1 RU high with distribution capability and rectifiers in the same shelf. Available in 19" and 23" widths, the system provides distribution space for (10) GMT fuses up to 15 A. Configuration options include battery low voltage disconnect (BLVD) or no low voltage disconnect. Internal Distribution up to 6 kw The 2 RU high configuration is also available in 19" and 23" widths with distribution capability and rectifiers in the same shelf. The system provides distribution space for GMT fuses up to 15 A or a combination of circuit breakers up to 100 A and GMT fuses. Configuration options include battery low voltage disconnect (BLVD), load low voltage disconnect (LLVD), or no low voltage disconnect. 4

Rectifier Shelves The rectifier shelves integrated into the NetSure 211 system are either 1.75" (1RU) or 3.5" (2 RU) high and available in 19" and 23" widths. These shelves provide front to back ventilation, maximizing revenuegenerating space. Each unit will operate from 120/208/240 VAC and is equipped to accommodate plug-in AC connections or open wire line cords. DC output connection options for each shelf include terminal blocks, plug-in DC jumpers for GMT load, and two-hole compression lugs for breakers. The shelf with rectifiers is UL Listed and meets FCC Class B EMI/RFI requirements. As load demand grows, the system can be easily expanded with additional modular components. Rectifiers The R48-500 and R48-1000 NetSure rectifiers are rated for 500 W or 1000 W constant output power when operated at 208/240 VAC nominal input. The 1000 W model rectifier provides approximately half its rated output when operated at 120 VAC. This auto-sensing circuit enables each rectifier to automatically adjust its output to the available line voltage. The rectifier will provide up to 100% of rated power at 45 C. As the temperature increases from 45 C to 75 C, the thermal power limit circuit linearly decreases power. In the typical operating range, these rectifiers have a total harmonic distortion less than 5%, and efficiencies greater than 92% (1000 W). Each hot-swappable rectifier has an integral multi-speed cooling fan and tri-led status indication. R48-1000, NetSure 211 Rectifier Controller The SCU+, ACU+ (for 2 RU systems only) and now the NCU are powerful control units that enable remote monitoring of the main AC supply, DC power plant, battery backup and site environment. The controller enables advanced battery management such as sophisticated boost charge control, remaining capacity testing, constant current discharge testing and scheduled discharge testing. With basic energy saving functions, the SCU+ is a cost-efficient system component. For more sophisticated site monitoring the ACU+ is available as an option for 2 RU systems only. The NCU supports multiple web browers including IE, Firefox, chrome and Safari. Standard supported protocols include ModBus, SNMP V2 & V3. Encrypted security is provided by IPv6 and SNMP V3. NCU Controller 5

NetSure 211 SERIES Distribution Output distribution for the NetSure 211 is available in four different forms. Internal distribution is attained through GMT fuses or circuit breakers. Internal distribution options include: (10) GMT fuses (1 RU); or 13 GMT fuses composed of a combination of 15 A positions and 10 Amp positions; or (4) load circuit breakers (0 A to 100 A) and (5) 10 A GMT fuses; or (2) load circuit breakers (0 A to 100 A) and (2) battery disconnect circuit breakers (0 A to 125 A) and (5) 10 A GMT positions. All distribution panel options are available with low-voltage disconnect capability. Battery Cabinet An enclosed battery cabinet is available that can be mounted on the wall or in a relay rack. A 40 A battery disconnect is included with the battery cabinet. It can be connected in parallel with other cabinets to provide additional backup time. Internal Distribution Configuration System Specifications, NetSure 211 INPUT System Voltage, Nominal Output Capacity Dimensions Access Control ENVIRONMENTAL Temperature Range, Operating Storage Humidity Ventilation EMI/RFI Safety Compliance 120 VAC, 208 VAC, 240 VAC 19" 1 RU up to 40 A 23" 1 RU up to 60 A Relay rack (can be mounted in enclosures) Mounting width: 19" or 23" width Integrated system Front for installation, operation and maintenance SCU+ controller, ACU+ controller (2 RU systems only), NCU controller 19" 2 RU up to 80 A 23" 2 RU up to 120 A Mounting Depth: Integrated distribution system 12" 1 RU Height 1.75" 2 RU Height 3.5" -40 C to +75 C (-40 F to +167 F) see rectifier specification for any derating* -40 C to +75 C (-40 F to +167 F) 0 to 95%, non-condensing Fan-cooled front to rear Conforms to FCC rules Part 15, Subpart B, Class B and EN55022 Class B, radiated and conducted UL 60950 Recognized (US & Canada) NEBS Level 3 Compliance *Operating and storage temperatures for batteries installed in the battery cabinet are provided by the battery manufacturer. 6

Rectifier Specifications, R48-500 and R48-1000 AC INPUT Input Voltage, Nominal 120 VAC, 208 VAC, 240 VAC Input Voltage, Operating Range 85 VAC to 300 VAC Frequency 45 Hz to 65 Hz Power Factor (PF) >0.90 for 25% to 50% load, >0.98 for 50% to 100% load and >0.99 for 100% load at 208 VAC, 220 VAC, 230 VAC, 240 VAC and 25 C Total Harmonic Distortion <5% from 50 to 100% of rated load at 208 Voc to 240 Voc Input Current, Maximum 6.5 A both 500 W and 1000 W Inrush Current Inrush current does not exceed 150% of the rated input steady state peak value Operating Efficiency 91% (500 W) 92% (1000 W) DC OUTPUT Output Voltage, Adjustment Range -42 VDC to -58 VDC Output Power Constant power limiting operation 500 W and 1000 W @ -48 VDC (for 1000 W, see derating chart for voltages less than 176 VDC or temperatures higher than 45 C) Output Current 10.42 A @ -48 VDC (500 W) 20.83 A @ -48 VDC (1000 W) Regulation Steady state output voltage remains within +/-1% for any combination of input voltage and temperature from 5% to 100% load Voice Band Noise The voice-frequency noise generated by a rectifier does not exceed 32 dbrnc output noise from 0% to 100% load Wide Band Noise Does not exceed 250 mv peak-to-peak, or 100 mv rms per Telcordia GR-947-CORE Psophometric Noise <1 mv at 0% to 100% of rated load; <32 dbrnc at 0% to 100% of rated load (output voltage > -42 V) Protection High voltage shutdown fixed and selective capability. Fixed requires manual restart. Selective If rectifier detects over voltage it will turn off. After 5 seconds it will restart; if it encounters an over voltage within 5 minutes it will turn off and remain off until reset. ENVIRONMENTAL Temperature -40 C to +75 C (-40 F to 167 F) Altitude 2000 m (6560 ft) at full power Ventilation Front to back with speed-controlled fan (field replaceable) Audible Noise The rectifier does not produce sound levels above 53 db(a), measured 0.6 m in front of the rectifier, at the same horizontal line as the middle of the rectifier at 25 C STATUS /ALARM INDICATORS AND MONITORING Visual Indicators Green LED: Normal Operation Yellow LED: Alarm Red LED: Failure Flashing Red LED: Fan Failure Status Settings The SCU+, ACU+ or NCU controller establishes all rectifier settings RECTIFIER PHYSICAL SPECIFICATIONS Mounting Plug-in installation Dimensions (H x W x D) 40.8 x 86.5 x 241 mm (1.6" x 3.4" x 9.5") Weight 1.25 kg (2.76 lbs) Safety Compliance UL 60950 Recognized (US & Canada) Additional Information For additional specification, engineering and installation information, request specification number 582136600 (system), 1R48500 or 1R481000 (rectifiers), or 541434 (battery cabinet). For ordering information on the complete system, request SAG582136600. 7

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2016 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. DC-00095 (R12/16)