VCD-23 Low Leakage CONTROL DAMPER

Similar documents
VCD-23. Low Leakage CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

VCD-23. Flange Options. Size Limitations

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Model FSD-212. Combination FIRE SMOKE DAMPERS

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Thermal Isolation. Break

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

AMD-33 Air Measuring Station with VCD-33 Control Damper

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331 Combination Fire Smoke Dampers

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-230 Industrial Control Damper

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

HVAC Control & Balancing Dampers

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

HVAC Control & Balancing Dampers

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Air Measuring Products AMD AMS IAQ

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

ID-141x 12-Gauge Hat Channel Industrial Damper

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

BD-1600 Balancing/Zone Control Damper

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Motorized Fire Dampers

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

LOW LEAKAGE VOLUME CONTROL DAMPER

Series HCD Airfoil Control Damper

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

DAMPERS WE CONTROL AIR

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

ARROW INDUSTRIAL PRODUCTS

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

PC-125x Counter-Balanced Backdraft Damper

CFSD Series. Product Description

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

VOLUME CONTROL DAMPER

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

SMOKE DAMPER - CLASS F MODEL BMSD

AD-1250 Airflow Measuring Station

L O U V E R S & D A M P E R S

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

When Time is Everything... We Manufacture in Days - Not Weeks!

VD-1600 Series Volume Control Dampers

SD-1250 and SD-1600 Series Smoke Dampers

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

SECTION CONTROL DAMPERS

ARROW UNITED INDUSTRIES

Fusible Link (replaceable) Horizontal Mount

Introduction to Johnson Controls Dampers

Blast Protection Damper

Blast Protection Damper

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

Installation, Operation and Maintenance Manual

Fusible Link (replaceable) Horizontal Mount

High Performance Axial Fans

AIR CONDITIONING PRODUCTS COMPANY

Installation, Operation, and Maintenance Instructions

Transcription:

Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available. Ratings (See page 4 for specific limitations) Pressure: Velocity: Leakage: Temperature: Up to 5.0 in. wg (1.2 kpa) - pressure differential Up to 3000 fpm (15.2 m/s) Class 1A @ 1 in. wg (.25 kpa) Class 1 @ up to 5 in. wg (1.2 kpa) Up to 250 F (121 C) (Consult Greenheck for higher temperatures) Low Leakage CONTROL DAMPER H* Construction Standard Optional Frame Material Galvanized Steel - Frame Thickness Frame Type 16 ga. (1.5mm) 5 in. x 1 in. (127mm x 25mm) Channel - Single flange, reversed flange, double flange Blade Material Galvanized steel - Blade Thickness 16 ga. - (1.5mm) Blade Type 3V - Blade Seals TPE Silicone Axle 1/2 in. dia. Plated - Steel Axle Bearings Synthetic Bronze Linkage Material Plated Steel - Jamb Seal 304SS - * W&H dimension furnished approximately 1/4 in. (6mm) undersize. Shown with optional extension pin and standoff bracket. Flange Options W* 5 in. 5 in. 5 in. 1 1/2 in. (Typical) Size Limitations W x H Minimum Size Maximum Size Single Multiple Section Section Inches 6 x 6 48 x 74 Unlimited mm 152 x 152 1219 x 1880 Unlimited Features & Options Blade seals - pressure activated to produce tighter sealing. Linkage concealed in the frame Low profile head and sill are used on sizes less than 17 in. (432mm) Wide range of electric actuators and manual quadrant available. Factory installation available. Sleeves available 5/8 in. - 2 in. (16mm - 51mm) flange available Retaining angles Transitions- R and C Open Close Indicator (OCI) Single Flange Blade Operation 5 in. 5 in. Parallel Blades Single Reversed Flange Shown with optional internally mounted actuator. 1 1/4 in. max. (typical) Opposed Blades Double Flange 1 1/4 in. max. (typical) Installation instructions available at www. greenheck.com.

Data This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.2 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. D 4 (W) (H) 3.14 Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. 6D Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system.

AMCA Certified Data Greenheck India Pvt. Ltd. and Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs.The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. AMCA 5.2 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 1000 0.05 1000 0.03 1000 0.02 1500 0.11 1500 0.06 1500 0.05 2000 0.19 2000 0.10 2000 0.09 2500 0.29 2500 0.16 2500 0.14 3000 0.41 3000 0.23 3000 0.19 3500 0.55 3500 0.30 3500 0.27 4000 0.72 4000 0.40 4000 0.35 12 in. x 48 in. (305mm x 1219mm) 1000 0.04 1500 0.08 2000 0.15 2500 0.22 3000 0.32 3500 0.43 4000 0.56 48 in. x 12 in. (1219mm x 305mm) 1000 0.03 1500 0.07 2000 0.12 2500 0.18 3000 0.26 3500 0.36 4000 0.47 AMCA 5.3 6D 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 1000 0.03 1000 0.02 1000 0.02 1500 0.08 1500 0.04 1500 0.03 2000 0.13 2000 0.07 2000 0.06 2500 0.20 2500 0.11 2500 0.09 3000 0.29 3000 0.16 3000 0.13 3500 0.40 3500 0.21 3500 0.19 4000 0.51 4000 0.28 4000 0.25 12 in. x 48 in. (305mm x 1219mm) 1000 0.03 1500 0.07 2000 0.12 2500 0.18 3000 0.26 3500 0.36 4000 0.46 48 in. x 12 in. (1219mm x 305mm) 1000 0.03 1500 0.06 2000 0.10 2500 0.16 3000 0.22 3500 0.30 4000 0.39 AMCA 5.5 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 500 0.03 500 0.03 500 0.02 1000 0.13 1000 0.12 1000 0.10 1500 0.30 1500 0.26 1500 0.22 2000 0.53 2000 0.47 2000 0.40 2500 0.82 2500 0.75 2500 0.62 3000 1.19 3000 1.04 3000 0.90 3500 1.62 3500 1.41 3500 1.23 4000 2.10 4000 1.90 4000 1.62 12 in. x 48 in. (305mm x 1219mm) 500 0.03 1000 0.12 1500 0.27 2000 0.47 2500 0.75 3000 1.07 3500 1.45 4000 1.91 48 in. x 12 in. (1219mm x 305mm) 500 0.03 1000 0.12 1500 0.28 2000 0.49 2500 0.77 3000 1.12 3500 1.53 4000 2.01

AMCA Certified Leakage Data Air leakage is based on operation between 32 F (0 C) and 120 F (49 C). Tested for leakage in accordance with ANSI/AMCA Standard 500-D, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-D, Figures 5.2, 5.3 and 5.5. Torque Data are based on a torque of 5.0 in.lb./ft² (0.56 N m) applied to close and seat the damper during the test. Leakage Class* Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) 5 in. wg (1.2 kpa) 48 in. (1219mm) 1A 1 1 Greenheck India Pvt. Ltd. and Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs.The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. *Leakage Class Definitions The maximum allowable leakage is defined by AMCA as the following: Leakage Class 1A - 3 cfm/ft 2 @ 1 in. wg (class 1A is only defined at 1 in. wg). Leakage Class 1-4 cfm/ft 2 @ 1 in. wg - 8 cfm/ft 2 @ 4 in. wg - 11 cfm/ft 2 @ 8 in. wg - 12.6 cfm/ft 2 @ 10 in. wg Velocity Limitations 74 60 Damper Height (in.) 48 36 24 3000 fpm 2500 fpm 2000 fpm 12 0 0 12 24 36 48 Damper Width (in.)

Application Data Space Envelopes On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the damper frame. B and T dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper is limited, each damper size should be individually evaluated. Damper frame T D Optional Jackshaft B Actuator Type/Model Height T B D Inches (mm) Inches (mm) >6 to <10 0 12.75 6 FSNF Series, Belimo >10 to <18 0 2 6 MSxx20 Series, Honeywell >18 0 0 6 FSLF, LF and TFB Series, >6 to <10 0 3.5 6 Belimo >10 0 0 6 MSxx04 & MSxx09 Series, >6 to <9 0 4.75 6 Honeywell >9 0 0 6 MS75xx Series, Honeywell >6 to <10 0 12.75 6 >10 to <18 0 7 6 >18 0 0 6 This drawing depicts the worse case clearance requirements for an actuator with a jackshaft. 7 3/4 in. (197mm) 3 3/4 in. (95mm) 1 1/4 in. (32mm) max. Actuator 5 3/8 in. (136.5mm) 5 in. (127mm)

Application Data Multi-Section Assembly Dampers larger than the maximum single section size, will be made up of a multiple of equal size sections. Multiple section dampers can be jackshafted together so that all sections operate together as shown below. NOTE: Dampers larger than 48 in. x 74 in. (1219mm x 1880mm) are not intended to be structurally self supporting. Additional horizontal bracing is recommended to support the weight of the damper and vertical bracing should be installed as required to hold against system pressure.

Specifications Specifications Control dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Damper blades shall be 16 ga. (1.5mm) galvanized steel 3V type with three longitudinal grooves for reinforcement. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow and operation in either direction through the damper (blades that are non-symmetrical relative to their axle pivot point or utilize blade stops larger than 1/2 in. [13mm] are unacceptable). Blade seals shall be TPE. Linkage shall be blade-to-blade concealed in jamb (out of the airstream) to protect linkage and reduce pressure drop and noise. Damper frame shall be 16 ga. (1.5mm) galvanized steel formed into a structural hat channel shape with reinforced corners to meet 11 ga. (3.1mm) criteria. Bearings shall be corrosion resistant, permanently lubricated, synthetic (acetal) sleeve type rotating in extruded holes in the damper frame for maximum service. Axles shall be square and positively locked into the damper blade. Jamb seals shall be flexible stainless steel compression type to prevent leakage between blade end and damper frame. The damper manufacturer s submittal data shall certify all air leakage and air performance pressure drop data is licensed in accordance with the AMCA Certified Ratings Program for Test Figures 5.2, 5.3 and 5.5. Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. Basis of design is Greenheek's model. Greenheck India: 541/542, 5th Floor, Tower-B3 Spaze Tech Park Sector-49, Sohna Road, Gurgaon www.greenheck.co.in Tel: 124-4272494 Fax: 011-91-124-4711263 Copyright 2014 Greenheck Fan Corporation Rev 17 December 2014