SITRANS F X SITRANS FX300 3/355

Similar documents
Flow Measurement SITRANS F X SITRANS FX300 4/365

SITRANS FX300 4/289. System Overview. Overview

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications

OPTISWIRL 4070 Technical Datasheet

OPTISWIRL 4070 Technical Datasheet

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

OPTISWIRL 4200 Technical Datasheet

OPTISWIRL 4200 Technical Datasheet

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Flow Measurement SITRANS F C

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Multivariable Vortex Flow Meter

SITRANS F C. Flow sensor MC2 4/193. Overview

Multivariable Vortex Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

Armstrong In-Line and Insertion Vortex Flow Meters

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

SITRANS F flowmeters SITRANS F C

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Vortex Flow Meter Model DVH

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Flow Measurement SITRANS F C

Vortex Flowmeter Model DVE

SITRANS FC. Flowmeter SITRANS FC410

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2500 SERIES VORTEX METER

SITRANS F M flow sensors 711/A and 711/911E

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Flow Measurement SITRANS F C

F-2600 SERIES INLINE VORTEX FLOW METER

OPTIMASS 2000 Technical Datasheet

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Flow Measurement SITRANS F M

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

OPTIMASS 3000 Technical Datasheet

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

VIM20 Vortex Insertion Flowmeter

Continuous level measurement Capacitance transmitters

Magnetic-inductive flow meter for hazardous areas

SITRANS F M. Flow sensor MAG 1100 F 3/59

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure

Level Measurement Point level measurement - RF Capacitance switches

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

STEEMCO Flowmeter for Steam

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

LCMass Series Mass Flow Sensor

Level Measurement Point level measurement - RF Capacitance switches

Vortex Eggs Delta Flowmeter

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Food & beverage. Oil & gas. Water & waste water

Level Measurement Continuous level measurement Ultrasonic transmitters

ORIMAS Mass Flowmeter

Pressure transducer DMU 01K Compact version

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

STEEMCO-MAS Flowmeter for Steam

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

F-1500 SERIES INSERTION TURBINE FLOW METER

OPTIFLUX 6000 Technical Datasheet

Flow Measurement SITRANS F M

Level Measurement Continuous level measurement - Capacitance transmitters

Point level measurement Capacitance switches

VORTEX IN-LINE FLOW METERS

Transmitting Transducer. Gas/Air Velocity Range:

Vortex In Line Flow Meter

The readings you need, right where you need them. AX Series Vortex Meters

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Pressure Measurement

VLM20 In-line Vortex Flowmeter

VIM20 Vortex Insertion Flowmeter

Flow Measurement SITRANS F C

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

SITRANS T measuring instruments for temperature

VIM20 Vortex Insertion Flowmeter

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Vortex In Line Flow Meter

SATRON VT Pressure Transmitter

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

BATCHFLUX 5500 C Technical Datasheet

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

The readings you need, right where you need them. AX Series Vortex Meters

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

KDM ARMORED FLOW METER & SWITCH

Micro Motion F-Series Coriolis Flow and Density Meters

Metal tube variable area flowmeter for gases, liquids and steam

Low Profile Insertion Vortex

Transcription:

Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure compensation. SITRANS FX00 The main applications of SITRANS FX00 can be found in the following sectors: Chemical Petrochemical Oil & Gas Power plants -Air - Heating - Cooling - Chilling Food & beverage - Pharmaceutical - Sugar refineries - Dairies -Breweries - Production of soft drinks Refining Water & waste water System Overview Version Flange Sandwich Dual transmitter Compact Benefits All devices have 2-wire technology and HART communication Temperature compensation for saturated steam as standard feature Integrated temperature and pressure measurement enabling direct compensation of density Pressure, temperature and flow can be read at a single point. No additional installation of pressure and temperature sensors Direct measurement of energy or energy consumption Optimum process reliability thanks to Intelligent Signal Processing (ISP) - stable readings, free of external perturbations Fully welded stainless steel construction with high corrosion, pressure and temperature resistance Maintenance-free sensor design Ready to use due to plug & play feature. No additional cabling work Minimal pressure drop Compact or remote design Pressure and temperature compensation for fluctuating volume flows Measurement of consumption in compressed air systems No risk of deposits or damage (sensor in the turbulent area) All units parameterized prior to delivery Application The SITRANS FX00 is a flowmeter in a single or dual transmitter version, suitable for measuring industrial steam, gases, as well as conductive and non-conductive liquids, e.g. steam (saturated steam, superheated steam), industrial gases (compressed air, nitrogen, liquefied gases, flue gases), and conductive and non-conductive liquids (demineralized water, boiler feed water, solvents, heat transfer oil). Remote Design The unit is available in a compact or a remote version with up to 5 meter distance from flowmeter to transmitter. When ordering a remote version the transducer cables are pre-mounted and ready for installation. Function Operating Principle vortex flowmeters measure flow rate by detecting the frequency at which alternating vortices are shed from a bluff body inserted into the flow stream. This principle of measurement is known as Von Karman s vortex street principle: alternating vortices form behind an object in a stream. The frequency of the alternating vortices is proportional to the flow rate. The passage of a vortex causes a slight stress on a pick-up placed downstream of the bluff body. The stress is picked up and counted as pressure surges by a dual Piezo crystal placed inside the wing. Siemens FI 0 204 US Edition /55

Flow Measurement Siemens AG 204 SITRANS FX00 Q d $ = Bluff Body, % = Pick-up The flowmeter calculates the flow velocity using the following equation: Q = A V = A d / St f = 0.9 f / K [m /h] Where: Q = flow rate [m /h] f = vortex shedding frequency [Hz] K = calibration constant [pulses/m ] d = width of the bluff body [m] St = Strouhal Number A = cross-section area [m 2 ] V = flow velocity [m/s] Requirements In order to generate the vortex streets, the medium must have a minimum velocity: For steam and gases, the flow velocity must be 2 to 80 m/s (6.6 to 262 ft/s) For liquids the flow velocity must be 0.4 to 0 m/s (. to 2.8 ft/s) Design SITRANS FX00 volumetric and mass flowmeter is available in the following configurations: SITRANS FX00 Single transmitter The single transmitter is available as a flange or sandwich solution in the following versions: Vortex standard flowmeter Measurement with integrated temperature sensor as standard feature Vortex flowmeter with pressure sensor Measurement with integrated temperature and pressure sensors for compensation of gases, wet gases, gas mixtures or steam (for engergy measurement). Vortex flowmeter with pressure sensor and isolation valve Allowing the pressure sensor to be shut off for the purpose of pressure or leak testing of the pipeline or for being exchanged without interrupting the process. Using the built-in two-way valve, the pressure sensor can also be calibrated and tested at a later time. Vortex flowmeter - remote version Sensors and tranmitters mounted separately. The device is equipped with temperature sensor (standard), pressure sensor (optional) and isolation valve (optional) providing all the features of the compact mounted version. SITRANS FX00 Dual transmitter This is a genuine redundant system with two independent sensors and two transmitters providing twofold functional reliability and availability of the measurement. This variant is optimally suited for measurements in multi-product pipelines. The dual converter is available as: Vortex standard flowmeter Measurement with temperature sensor for saturated steam compensation as standard feature 2 Technical specifications Input Measuring range limits See Dimensional Drawings Media pressure... 00 bar (4.5... 450 psi) (Higher pressures on request) Output Current output Measuring range 4 20 ma Over range 20.8 ma % (05% %) Load -min. 00 -max. R max = (U Power Supply - 4 V)/22 ma Error signal NAMUR NE 4 Maximum output 22 ma (2.5 %) Multidrop mode 4 ma Digital output Communication HART Physical layer FSK Device category Transmitter Pulse output (Passive pulse output, needs separate power supply. Pulse output has to be defined in the Option menu Y47 totalizer or energy unit has to be entered. E.g.: pulse/kg or pulse/0 m³) Pulse frequency Max. 0.5 Hz Power supply Min. 24 V DC as NAMUR or Non-Ex version open < ma, max. 6 V, closed 00 ma, U < 2 V Ex version open < ma, max. 0 V, closed 00 ma, U < 2 V Accuracy Standard version For liquids -Re 20 000 0.75 % For steam and gases -Re 20 000 % For steam, gases and liquids - 0 000 < Re < 20 000 2% Pressure and temperaturecompensated version For liquids - 0 000 < Re < 20 000 2% -Re 20 000 0.75 % For gases and steam - 0 000 < Re < 20 000 2.5 % -Re 20 000.5 % Repeatability 0. % Installation conditions (At different conditions, e.g. installation after control valve, bends or reductions, please refer to the operating instructions.) Inlet run 20 x DN Outlet run 5 x DN /56 Siemens FI 0 204 US Edition

Siemens AG 204 Flow Measurement Software Uncompensated for gases, steam and liquids, but temperature-compensated for saturated steam Density-compensated by temperature and pressure for superheated steam, no energy calculation Gross heat When the thermal energy of steam is to be measured In options Y5 to Y56 add information regarding: Order option Order option 4 Order option 5 Y5 Variable current output Y52 Power unit Select one of the following units from power units table in Y52: kj/h, MJ/h, GJ/h, Btu/h, kcal/h, kw, MW or special (custom) Y5 Fullscale power value Y54 Variable pulse output Y55 Totalizer on/off Y56 Configures for totalizer select one of the following units from energy units table in Y56: kj, MJ, GJ, Btu th, kcal, kwh, MWh or special (custom). Density compensated by temperature and pressure for gases, wet Order option 7 gases Wet gases Select Y49 and enter relative humidity in % FAD - Free Air Delivery When the delivered air of a compressor is to be Order option 8 measured In Y8 to Y87 add information regarding: Mixed gases Y8 Inlet suction temperature Y82 Atmosphere pressure Y8 Pressure drop at inlet filter Y84 Inlet relative humidity Y85 Actual revolutions per minute (of compressor) Y86 Rated rpm of compressor Y87 Outlet relative humidity. This information is available from compressor supplier. When the fluid is a gas mixture, contact your local Siemens representative and provide gas names and amount in %. Rated operation conditions Ambient temperature Non-Ex version -40 +85 C(-40 +85 F) Ex version -40 +65 C(-40 +49 F) Storage temperature -50 +85 C(-58 +85 F) Media temperature -40 +240 C (-40 +464 F) Density Taken into consideration when rating Viscosity <0 cp Reynolds number 0 000 2 00 000 Media pressure limit Max. 00 bar (450 psi) Higher pressure on request (contact your local Siemens representative) SITRANS FX00 Design Material Sensor: house/pick-up AISI 6L (.4404)/ AISI 6L (.445) Hastelloy C22/2.4602 available on request (contact your local Siemens representative) Housing: transmitter Aluminum for increased requirements Sensor gaskets (Pick-up/Pressure sensor) AISI 6L (.445) / FPM or FFKM FPM (Viton) for steam and non-aggressive gases. FFKM (Kalrez) for chlorine and other aggressive gases. (FPM/FFKM gaskets are only supplied if FX00 is configured with pressure sensor) Process connections Flange norm EN 092- form B/B2 or ASME B6.5 RF. Other flanges on request (contact your local Siemens representative) Flange version DN5 00 (½ 2") Sandwich version DN5 00 (½ 4") Degree of protection IP66/IP67 Dimensions and weights See Dimensional Drawings Display and operating interface Local display 2 lines, 0 characters per line Languages German, English, French Power supply Standard version 4 6 V DC Ex version 4 0 V DC Certificates and approvals Explosion protection ATEX II 2G EEx d ia [ia] IIC T6 FM US/C Class I, II, III, Div. and 2 Calibration All flowmeters will be delivered with a point calibration certificate Material Certificate Certificate of compliance, pressure test, material certificate, material in acc. of NACE and PMI of pressure bearing metal parts. Cleaning Choose Cleaning Class when fluid is oxygen or contains chloride. Certificates X-ray test on pressurized weldings and dye penetration test on pressure bearing weldings Dye penetration test Siemens FI 0 204 US Edition /57

Flow Measurement Siemens AG 204 SITRANS FX00 Selection and Ordering data Article No. Ord. code SITRANS FX00 Flanged 7ME2600- Single transmitter and T max = 240 C (464 F) 7 7 7 7 7-7 7 7 7 7 7 7 Connection size Sensor size DN 5 (½") DN 5 A DN 25 (") DN 25 2B DN 40 (½") DN 40 2K DN 50 (2") DN 50 2R DN 80 (") DN 80 L DN 00 (4") DN 00 S DN 50 (6") DN 50 4M DN 200 (8") DN 200 4T DN 250 (0") DN 250 4W DN 00 (2") DN 00 5E Flange norm and nominal pressure Form B/B2 EN 092- PN 0 DN 200... 00 A PN 6 DN 50... 00 B PN 25 DN 200... 00 C PN 40 DN 5... 00 D PN 6 DN 50... 50 E PN 00 DN 5... 50 F RF ASME B6.5 50 lb ½... 2" J 00 lb ½... 2" K 600 lb ½... 6" L Sensor material/gasket St. steel AISI 6L (.4404)/AISI 6L (.445)/ FPM St. steel AISI 6L (.4404)/AISI 6L 5 (.445)/ FFKM Transmitter design Compact version - no cable Remote version: 5 m (6.4 ft) 2 0 m (2.8 ft) 5 m (49.2 ft) 4 Approval and cable gland Non-Ex, M20 x.5 Non-Ex, ½ NPT 2 FM approval Class Div. 2, M20 x.5 ATEX, M20 x.5 4 ATEX, ½ NPT 5 FM approval Class Div., M20 x.5 6 FM approval Class Div., /2" NPT 7 FM approval Class Div. 2, /2" NPT 8 Further approvals and cable glands IEC Ex with M20 x.5 9 N 0 A IEC Ex with ½" NPT 9 N 0 B Transmitter, display and communication With display, HART A Selection and Ordering data Article No. Ord. code SITRANS FX00 Flanged 7ME2600- Single transmitter and T max = 240 C (464 F) 7 7 7 7 7-7 7 7 7 7 7 7 Pressure sensor and isolation valve Without pressure sensor A With pressure sensor, range: 4 bar (58 psi) B 6 bar (87 psi) D 0 bar (45 psi) E 6 bar (22 psi) G 25 bar (6 psi) H 40 bar (580 psi) K 60 bar (870 psi) L 00 bar (450 psi) N With isolation valve and pressure sensor, range: 4 bar (58 psi) P 6 bar (87 psi) Q 0 bar (45 psi) R 6 bar (22 psi) S 25 bar (6 psi) U 40 bar (580 psi) V 60 bar (870 psi) W 00 bar (450 psi) Y Software Uncompensated for gases, wet gases, steam and liquids, respectively, temperature compensation for saturated steam Density compensation for superheated 4 steam Density compensation for superheated 5 steam and setting of Gross heat Opt. Y5... Y56 for Energy measuring Density compensation for gases and wet 7 gases and setting of Relative humidity at opt. Y49 Density compensation for gases, wet gases 8 and setting of FAD - free air delivery Opt. Y49 and Y8... Y87 for Compressor settings /58 Siemens FI 0 204 US Edition

Siemens AG 204 Flow Measurement Selection and Ordering data Additional information Please add -Z to Article No. and specify as minimum Order code Y40, Y4, Y42 and Y45 and plain text. Input process data Medium: Specify steam, gas, liquid or customised Temperature: Specify max. operating temperature and units Pressure: Specify max. operating pressure and units Density (only by customer-specified medium): Specify medium density and units Viscosity (only by customer-specified medium): Specify medium viscosity and units Flow rate: Specify min./max. flow rate and units Setting of pulse output: Specify totalizer or energy unit ( pulse/unit) Relative humidity (amount in % of process medium) Settings of gross heat Variable current output Power unit (specify: kj/h, MJ/h, GJ/h, Btu/h, kcal/h, kw, MW or special (custom)) Fullscale power value Variable pulse output Totalizer on/off Configure totalizer (specify: kj, MJ, GJ, Btu th, kcal, kwh, MWh or special (custom)) Settings of FAD Inlet suction temperature ) Atmosphere pressure ) Pressure drop filter 2) Inlet relative humidity ) Actual revolutions per minute (of compressor) 2) Rated Rpm of compressor 2) Outlet relative humidity 2) Order code Y40 Y4 Y42 Y4 Y44 Y45 Y47 Y49 Y5 Y52 Y5 Y54 Y55 Y56 Y8 Y82 Y8 Y84 Y85 Y86 Y87 ) Information to be provided by customer. 2) Information is available on the data sheet from the compressor supplier. Operating instructions Description English Article No. A5E20042 SITRANS FX00 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is also available for free at: http://www.siemens.com/flowdocumentation Selection and Ordering data Further designs Please add -Z to Article No. and specify Order code. Converter housing material Aluminum for increased requirement, color: petrol green Material certificate Certificate of compliance EN 0204-2. Pressure test +. accordance EN 0204 Material certificate pressure parts + certificate. Material in accordance with NACE MR 075-0 PMI of pressure bearing metal parts + certificate. Material certificate pressure parts + PMI/certificate. Calibration certificate FX00 As standard the flow device has a -point calibration certificate. Calibration certificate (5 point) Hardness test Hardness test on pressure bearing parts +. Equotip LD procedure according to NACE MR 075-0 Cleaning for oil and fat Class increased requirement (customer-specified) and. (EN 0204) Class 2 and. (EN 0204) Certificates X-ray test on pressure bearing weldings Dye penetration test on pressure bearing weldings Tag name plate Stainless steel tag with mm characters, max. 2 x 8 characters (40 x 20 mm, add plain text) Stainless steel tag with 2.5 mm characters, max. 8 x 40 characters (20 x 46 mm, add plain text) Order code A0 C0 C C2 C C4 C5 D H0 K46 K48 M56 M58 Y7 Y8 Siemens FI 0 204 US Edition /59

Flow Measurement Siemens AG 204 SITRANS FX00 Selection and Ordering data Article No. Ord. code SITRANS FX00 Sandwich Single transmitter and 7ME2700- T max = 240 C (464 F) 7 7 7 7 7-7 7 7 7 7 7 7 Connection size Sensor size DN 5 (½") DN 5 A DN 25 (") DN 25 2B DN 40 (½") DN 40 2K DN 50 (2") DN 50 2R DN 80 (") DN 80 L DN 00 (4") DN 00 S Nominal pressure EN PN 6 DN 50... 00 B PN 40 DN 5... 00 D PN 6 DN 50... 00 E PN 00 DN 5... 00 F ASME 50 lb ½... 4" J 00 lb ½... 4" K 600 lb ½... 4" L Sensor material/gasket St. steel AISI 6L (.4404)/AISI 6L (.445)/FPM St. steel AISI 6L (.4404)/AISI 6L 5 (.445)/FFKM Transmitter design Compact version - no cable Remote version: 5 m (6.4 ft) 2 0 m (2.8 ft) 5 m (49.2 ft) 4 Approval and cable gland Non-Ex, M20 x.5 Non-Ex, ½ NPT 2 FM approval Class Div. 2, M20 x.5 ATEX, M20 x.5 4 ATEX, ½ NPT 5 FM approval Class Div., M20 x.5 6 FM approval Class Div., /2" NPT 7 FM approval Class Div. 2, /2" NPT 8 Further approvals and cable glands IEC Ex with M20 x.5 9 N 0 A IEC Ex with ½" NPT 9 N 0 B Transmitter, display and communication With display, HART A Selection and Ordering data Article No. Ord. code SITRANS FX00 Sandwich Single transmitter and 7ME2700- T max = 240 C (464 F) 7 7 7 7 7-7 7 7 7 7 7 7 Pressure sensor and isolation valve Without pressure sensor A With pressure sensor, range: 4 bar (58 psi) B 6 bar (87 psi) D 0 bar (45 psi) E 6 bar (22 psi) G 25 bar (6 psi) H 40 bar (580 psi) K 60 bar (870 psi) L 00 bar (450 psi) N With isolation valve and pressure sensor, range: 4 bar (58 psi) P 6 bar (87 psi) Q 0 bar (45 psi) R 6 bar (22 psi) S 25 bar (6 psi) U 40 bar (580 psi) V 60 bar (870 psi) W 00 bar (450 psi) Y Software Uncompensated for gases, wet gases, steam and liquids respectively temperature compensation for saturated steam Density compensation for superheated steam 4 Density compensation for superheated steam 5 and setting of Gross heat Opt. Y5... Y56 for Energy measuring Density compensation for gases and wet 7 gases and setting of Relative humidity at opt. Y49 Density compensation for gases, wet gases 8 and setting of FAD - free air delivery Opt. Y49 and Y8... Y87 for Compressor settings /60 Siemens FI 0 204 US Edition

Siemens AG 204 Flow Measurement Selection and Ordering data Additional information Please add -Z to Article No. and specify as minimum Order code Y40, Y4, Y42 and Y45 and plain text. Input process data Medium: Specify steam, gas, liquid and customised Temperature: Specify max. operating temperature and units Pressure: Specify max. operating pressure and units Density (only by customer-specified medium): Specify medium density and units Viscosity (only by customer-specified medium): Specify medium viscosity and units Flow rate: Specify min./max. flow rate and units Setting of pulse output: Specify totalizer or energy unit ( pulse/unit) Relative humidity (amount in % of process medium) Settings of gross heat Variable current output Power unit (specify: kj/h, MJ/h, GJ/h, Btu/h, kcal/h, kw, MW or special (custom)) Fullscale power value Variable pulse output Totalizer on/off Configure totalizer (specify: kj, MJ, GJ, Btu th, kcal, kwh, MWh or special (custom)) Settings of FAD Inlet suction temperature ) Atmosphere pressure ) Pressure drop filter 2) Inlet relative humidity ) Actual revolutions per minute (of compressor) 2) Rated Rpm of compressor 2) Outlet relative humidity 2) Order code Y40 Y4 Y42 Y4 Y44 Y45 Y47 Y49 Y5 Y52 Y5 Y54 Y55 Y56 Y8 Y82 Y8 Y84 Y85 Y86 Y87 ) Information to be provided by customer. 2) Information is available on the data sheet from the compressor supplier. Operating instructions Description English Article No. A5E20042 SITRANS FX00 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is also available for free at: http://www.siemens.com/flowdocumentation Selection and Ordering data Further designs Please add -Z to Article No. and specify Order code. Converter housing material Aluminum for increased requirement, color: petrol green Material certificate Certificate of compliance EN 0204-2. Pressure test +. accordance EN 0204 Material certificate pressure parts + certificate. Material in accordance with NACE MR 075-0 PMI of pressure bearing metal parts + certificate. Material certificate pressure parts + PMI/certificate. Calibration certificate FX00 As standard the flow device has a -point calibration certificate. Calibration certificate (5-point) Hardness test Hardness test on pressure bearing parts +. Equotip LD procedure according to NACE MR 075-0 Cleaning for oil and fat Class increased requirement (customer-specified) and. (EN 0204) Class 2 and. (EN 0204) Certificates X-ray test on pressure bearing weldings Dye penetration test on pressure bearing weldings Tag name plate Stainless steel tag with mm characters, max. 2 x 8 characters (40 x 20 mm, add plain text) Stainless steel tag with 2.5 mm characters, max. 8 x 40 characters (20 x 46 mm, add plain text) Order code A0 C0 C C2 C C4 C5 D H0 K46 K48 M56 M58 Y7 Y8 Siemens FI 0 204 US Edition /6

Flow Measurement Siemens AG 204 SITRANS FX00 Selection and Ordering data Article No. Ord. code SITRANS FX00 Flanged Dual transmitter and 7ME2800- T max = 240 C (464 F) 7 7 7 7 7-7 7 7 7 7 7 7 Connection size Sensor size DN 40 (½") DN 40 2K DN 50 (2") DN 50 2R DN 80 (") DN 80 L DN 00 (4") DN 00 S DN 50 (6") DN 50 4M DN 200 (8") DN 200 4T DN 250 (0") DN 250 4W DN 00 (2") DN 00 5E Flange norm and nominal pressure Form B/B2 EN 092- PN 0 DN 200... 00 A PN 6 DN 50... 00 B PN 25 DN 200... 00 C PN 40 DN 40... 00 D PN 6 DN 50... 50 E PN 00 DN 40... 50 F RF ASME B6.5 50 lb ½... 2" J 00 lb ½... 2" K 600 lb ½... 6" L Sensor material/gasket Stainless steel AISI 6L (.4404)/ AISI 6L (.445)/FPM Stainless steel AISI 6L (.4404)/ 5 AISI 6L (.445)/FFKM Transmitter design Compact version - no cable Remote version: 5 m (6.4 ft) 2 0 m (2.8 ft) 5 m (49.2 ft) 4 Approval and cable gland Non-Ex, M20 x.5 Non-Ex, ½ NPT 2 FM approval Class Div. 2, M20 x.5 ATEX, M20 x.5 4 ATEX, ½ NPT 5 FM approval Class Div., M20 x.5 6 FM approval Class Div., /2" NPT 7 FM approval Class Div. 2, /2" NPT 8 Further approvals and cable glands IEC Ex with M20 x.5 9 N 0 A IEC Ex with ½" NPT 9 N 0 B Transmitter, display and communication With display, HART A Pressure sensor and isolation valve Without pressure sensor A Software Uncompensated for gases, wet gases, steam and liquids respectively temperature compensation for saturated steam Selection and Ordering data Additional information Please add -Z to Article No. and specify as minimum Order code Y40, Y4, Y42 and Y45 and plain text. Input process data Medium: Specify steam, gas, liquid and customised Temperature: Specify max. operating temperature and units Pressure: Specify max. operating pressure and units Density (only by customer-specified medium): Specify medium density and units Viscosity (only by customer-specified medium): Specify medium viscosity and units Flow rate: Specify min./max. flow rate and units Setting of pulse output; Specify totalizer or energy unit ( pulse/unit) Relative humidity (amount in % of process medium) Operating instructions for SITRANS FX00 Description Article No. English A5E20042 Order code Y40 Y4 Y42 Y4 Y44 Y45 Y47 Y49 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is also available for free at: http://www.siemens.com/flowdocumentation Selection and Ordering data Further designs Please add -Z to Article No. and specify Order code. Converter housing material Aluminum for increased requirement, color: petrol green Material certificate Certificate of compliance EN 0204-2. Pressure test +. accordance EN 0204 Material certificate pressure parts + certificate. Material in accordance with NACE MR 075-0 PMI of pressure bearing metal parts + certificate. Material certificate pressure parts + PMI/certificate. Calibration certificate FX00 As standard the flow device has a -point calibration certificate. Calibration certificate (5-point) Hardness test Hardness test on pressure bearing parts +. Equotip LD procedure according to NACE MR 075-0 Cleaning for oil and fat Class increased requirement (customer-specified) and. (EN 0204) Class 2 and. (EN 0204) Certificates X-ray test on pressure bearing weldings Dye penetration test on pressure bearing weldings Tag name plate Stainless steel tag with mm characters, max. 2 x 8 characters (40 x 20 mm, add plain text) Stainless steel tag with 2.5 mm characters, max. 8 x 40 characters (20 x 46 mm, add plain text) Order code A0 C0 C C2 C C4 C5 D H0 K46 K48 M56 M58 Y7 Y8 /62 Siemens FI 0 204 US Edition

Siemens AG 204 Flow Measurement SITRANS FX00 SITRANS FX00 spare parts Description Article No. Seal disc 2.8-2-0. A5E02849 Socket only for DN 5/25 ; /2" Socket only for DN 5/25 ; " Pickup AISI 6L/.4404 On request On request On request O-ring pickup A5E028464 Description Service Toolbox for programming the software (basic, steam and gas) as well as for changing settings and parameters. Note: Dedicated service training is required. Please contact Customer Support. Article No. A5E027589 O-ring for pressure screw A5E028488 7. x 2.62-FPM-70 Pressure sensor On request 4/6/0/6/25/40/60/00 bar Cover gasket O-Ring A5E028492 9.67 x.5 Converter housing gasket A5E028495 59,5,5-2-N O-ring DIN77-20 x -FPM for A5E02855 sensor O-ring 0x2-NBR for leadthrough A5E028525 DUBOX plug, 5-pole-RM2 A5E028527 Electronic Basic D-HART A5E0285 Schematics 2 2 Power supply Load - + ma Ampere meter, optional HART A A+ B B+ Steam D-HART Gas D-HART A5E02854 A5E028544 Load for HART communication HART Display Cable feedthrough 0-pole (non-ex). O-ring for cable feedthrough 2.89 x 2.62 0-pole plug Sensor replacement (incl. Seal disc, pickup, O-rings for pickup, and pressure screw DN 5 (incl. ½" socket) A5E028558 A5E028562 A5E028087 2 Power supply Load - + - + Connection pulse output ma 2 + - 4 Ampere meter, optional 4 Counter A A+ B B+ DN 25 (incl. " socket) A5E0286 DN 40... 00 A5E02852 DN 50... 00 A5E0227505 Pressure sensor replacement (Incl. pressure sensor, DUBOX plug, 2 O-rings and calibration certificate) 4 bar (58 psi) A5E02857 6 bar (87 psi) A5E02875 0 bar (45 psi) A5E02880 6 bar (22 psi) A5E02822 25 bar (6 psi) A5E02807 40 bar (580 psi) A5E0286 60 bar (870 psi) A5E02822 00 bar (450 psi) A5E02847 Siemens FI 0 204 US Edition /6

Flow Measurement Siemens AG 204 SITRANS FX00 Dimensional drawings Compact version a c b a c b D H H l L d Flange version Flange version with pressure sensor a D H D L d L H Flange version, dual converter /64 Siemens FI 0 204 US Edition

Siemens AG 204 Flow Measurement SITRANS FX00 Flange version EN092- Size Pressure rating Dimensions [mm (inch)] Weight [kg (lb)] ) DN PN a b c d D L H l Flowmeter (without pressure sensor) Flowmeter (with pressure sensor) 5 40 (5.24) 05 (4.) 79 (7.05) 7. (0.68) 95 (.74) 200 (7.87) 265 (0.4) 44 (5.67) 5.5 (2.) 6. (.45) 5 00 (5.24) 05 (4.) 79 (7.05) 7. (0.68) 05 (4.) 200 (7.87) 265 (0.4) 44 (5.67) 6.5 (4.) 7. (5.65) 25 40 (5.24) 05 (4.) 79 (7.05) 28.5 (.2) 5 (4.5) 200 (7.87) 265 (0.4) 44 (5.67) 7. (6.09) 7.9 (7.42) 25 00 (5.24) 05 (4.) 79 (7.05) 28.5 (.2) 40 (5.5) 200 (7.87) 265 (0.4) 44 (5.67) 9. (20.50) 9.9 (2.8) 40 40 (5.24) 05 (4.) 79 (7.05) 4. (.70) 50 (5.9) 200 (7.87) 270 (0.6) 44 (5.67) 0.2 (22.49) 0.8 (2.8) 40 00 (5.24) 05 (4.) 79 (7.05) 42.5 (.67) 70 (6.69) 200 (7.87) 270 (0.6) 44 (5.67) 4.2 (.) 4.8 (2.6) 50 6 (5.24) 05 (4.) 79 (7.05) 54.5 (2.5) 65 (6.50) 200 (7.87) 275 (0.8) 44 (5.67) 2. (26.68) 2.7 (28.00) 50 40 (5.24) 05 (4.) 79 (7.05) 54.5 (2.5) 65 (6.50) 200 (7.87) 275 (0.8) 44 (5.67) 2. (27.2) 2.9 (28.44) 50 6 (5.24) 05 (4.) 79 (7.05) 54.5 (2.5) 80 (7.09) 200 (7.87) 275 (0.8) 44 (5.67) 6. (5.94) 6.9 (7.26) 50 00 (5.24) 05 (4.) 79 (7.05) 5.9 (2.2) 95 (7.68) 200 (7.87) 275 (0.8) 44 (5.67) 7.8 (9.24) 8.4 (40.57) 80 6 (5.24) 05 (4.) 79 (7.05) 82.5 (.25) 200 (7.87) 200 (7.87) 290 (.42) 54 (6.06) 6.8 (7.04) 7.4 (8.6) 80 40 (5.24) 05 (4.) 79 (7.05) 82.5 (.25) 200 (7.87) 200 (7.87) 290 (.42) 54 (6.06) 8.8 (4.45) 9.4 (42.77) 80 6 (5.24) 05 (4.) 79 (7.05) 8.7 (.22) 25 (8.46) 200 (7.87) 290 (.42) 54 (6.06) 22.8 (50.27) 2.4 (5.59) 80 00 (5.24) 05 (4.) 79 (7.05) 80.9 (.9) 20 (9.06) 200 (7.87) 290 (.42) 54 (6.06) 26.8 (59.08) 27.4 (60.4) 00 6 (5.24) 05 (4.) 79 (7.05) 07. (4.22) 220 (8.66) 250 (9.84) 0 (2.20) 64 (6.46) 2.4 (47.8) 22 (48.50) 00 40 (5.24) 05 (4.) 79 (7.05) 07. (4.22) 25 (9.25) 250 (9.84) 0 (2.20) 64 (6.46) 24.4 (5.79) 25 (55.2) 00 6 (5.24) 05 (4.) 79 (7.05) 06. (4.9) 250 (9.84) 250 (9.84) 0 (2.20) 64 (6.46) 29.4 (64.82) 0 (66.4) 00 00 (5.24) 05 (4.) 79 (7.05) 04. (4.) 265 (0.4) 250 (9.84) 0 (2.20) 64 (6.46) 5.4 (78.04) 6 (79.7) 50 6 (5.24) 05 (4.) 79 (7.05) 59. (6.27) 285 (.22) 00 (.8) 25 (2.80) 74 (6.85) 5.2 (77.60) 5.8 (78.9) 50 40 (5.24) 05 (4.) 79 (7.05) 59. (6.27) 00 (.8) 00 (.8) 25 (2.80) 74 (6.85) 4.2 (90.8) 4.8 (92.5) 50 6 (5.24) 05 (4.) 79 (7.05) 57. (6.9) 45 (.58) 00 (.8) 25 (2.80) 74 (6.85) 59.2 (0.5) 59.8 (.84) 50 00 (5.24) 05 (4.) 79 (7.05) 54. (6.07) 55 (.98) 00 (.8) 25 (2.80) 74 (6.85) 67.2 (48.5) 67.8 (49.47) 200 0 (5.24) 05 (4.) 79 (7.05) 206.5 (8.) 40 (.9) 00 (.8) 50 (.78) 94 (7.64) 7.8 (8.) 8.4 (84.66) 200 6 (5.24) 05 (4.) 79 (7.05) 206.5 (8.) 40 (.9) 00 (.8) 50 (.78) 94 (7.64) 7.8 (8.) 8.4 (84.66) 200 25 (5.24) 05 (4.) 79 (7.05) 206.5 (8.) 60 (4.7) 00 (.8) 50 (.78) 94 (7.64) 46.8 (0.8) 47.4 (04.50) 200 40 (5.24) 05 (4.) 79 (7.05) 206.5 (8.) 75 (4.76) 00 (.8) 50 (.78) 94 (7.64) 54.8 (20.8) 55.4 (22.4) 250 0 (5.24) 05 (4.) 79 (7.05) 260.4 (0.25) 95 (5.55) 80 (4.96) 70 (4.57) 224 (8.82) 57.4 (26.55) 58.0 (27.87) 250 6 (5.24) 05 (4.) 79 (7.05) 260.4 (0.25) 405 (5.94) 80 (4.96) 70 (4.57) 224 (8.82) 58.4 (28.75) 59.0 (0.07) 250 25 (5.24) 05 (4.) 79 (7.05) 258.8 (0.9) 425 (6.7) 80 (4.96) 70 (4.57) 224 (8.82) 74.4 (64.02) 75.0 (65.5) 250 40 (5.24) 05 (4.) 79 (7.05) 258.8 (0.9) 450 (7.72) 80 (4.96) 70 (4.57) 224 (8.82) 92.4 (20.7) 9.0 (205.0) 00 0 (5.24) 05 (4.) 79 (7.05) 09.7 (2.9) 445 (7.52) 450 (7.72) 95 (5.55) 244 (9.6) 75.7 (66.89) 76. (68.2) 00 6 (5.24) 05 (4.) 79 (7.05) 09.7 (2.9) 460 (8.) 450 (7.72) 95 (5.55) 244 (9.6) 82.2 (8.22) 82.8 (82.54) 00 25 (5.24) 05 (4.) 79 (7.05) 07.9 (2.2) 485 (9.09) 450 (7.72) 95 (5.55) 244 (9.6) 98.7 (27.60) 99. (28.92) 00 40 (5.24) 05 (4.) 79 (7.05) 07.9 (2.2) 55 (20.28) 450 (7.72) 95 (5.55) 244 (9.6) 27.5 (28.09) 28. (282.4) ) For dual converter: specified weight + 2.80 kg (6.7 lb). Siemens FI 0 204 US Edition /65

Flow Measurement Siemens AG 204 SITRANS FX00 Flange version ASME B6.5 Size Pressure rating Dimensions [mm (inch)] Weight [kg (lb)] ) DN Class a b c d D L H l Flowmeter Flowmeter (without (with pressure pressure sensor) sensor) ½ 50 (5.24) 05 (4.) 79 (7.05) 5.8 (0.62) 90 (.54) 200 (7.87) 265 (0.4) 44 (5.67) 4.5 (9.92) 5. (.24) ½ 00 (5.24) 05 (4.) 79 (7.05) 5.8 (0.62) 95 (.74) 200 (7.87) 265 (0.4) 44 (5.67) 4.9 (0.80) 5.5 (2.) ½ 600 (5.24) 05 (4.) 79 (7.05).9 (0.55) 95 (.74) 200 (7.87) 265 (0.4) 44 (5.67) 5. (.24) 5.7 (2.57) 50 (5.24) 05 (4.) 79 (7.05) 26.6 (.05) 0 (4.) 200 (7.87) 265 (0.4) 44 (5.67) 6.2 (.67) 6.8 (4.99) 00 (5.24) 05 (4.) 79 (7.05) 26.6 (.05) 25 (4.92) 200 (7.87) 265 (0.4) 44 (5.67) 7.2 (5.87) 7.8 (7.20) 600 (5.24) 05 (4.) 79 (7.05) 24. (0.96) 25 (4.92) 200 (7.87) 265 (0.4) 44 (5.67) 7.5 (6.5) 8. (7.86) ½ 50 (5.24) 05 (4.) 79 (7.05) 40.9 (.6) 25 (4.92) 200 (7.87) 270 (0.6) 44 (5.67) 8. (8.0) 8.9 (9.62) ½ 00 (5.24) 05 (4.) 79 (7.05) 40.9 (.6) 55 (6.0) 200 (7.87) 270 (0.6) 44 (5.67) 0.4 (22.9) (24.25) ½ 600 (5.24) 05 (4.) 79 (7.05) 8. (.50) 55 (6.0) 200 (7.87) 270 (0.6) 44 (5.67).4 (25.) 2 (26.46) 2 50 (5.24) 05 (4.) 79 (7.05) 52.6 (2.07) 50 (5.9) 200 (7.87) 275 (0.8) 44 (5.67) (24.25).6 (25.57) 2 00 (5.24) 05 (4.) 79 (7.05) 52.6 (2.07) 65 (6.50) 200 (7.87) 275 (0.8) 44 (5.67) 2.4 (27.4) (28.66) 2 600 (5.24) 05 (4.) 79 (7.05) 49. (.94) 65 (6.50) 200 (7.87) 275 (0.8) 44 (5.67).9 (0.64) 4.5 (.97) 50 (5.24) 05 (4.) 79 (7.05) 78 (.07) 90 (7.48) 200 (7.87) 290 (.42) 54 (6.06) 9.8 (4.65) 20.4 (44.97) 00 (5.24) 05 (4.) 79 (7.05) 78 (.07) 20 (8.27) 200 (7.87) 290 (.42) 54 (6.06) 22.8 (50.27) 2.4 (5.59) 600 (5.24) 05 (4.) 79 (7.05) 7.7 (2.90) 20 (8.27) 200 (7.87) 290 (.42) 54 (6.06) 2.8 (52.47) 24.4 (5.79) 4 50 (5.24) 05 (4.) 79 (7.05) 02.4 (4.0) 20 (9.06) 250 (9.84) 0 (2.20) 64 (6.46) 2.4 (5.59) 24 (52.9) 4 00 (5.24) 05 (4.) 79 (7.05) 02.4 (4.0) 255 (0.04) 250 (9.84) 0 (2.20) 64 (6.46).4 (69.2) 2 (70.55) 4 600 (5.24) 05 (4.) 79 (7.05) 97.2 (.8) 275 (0.8) 250 (9.84) 0 (2.20) 64 (6.46) 40.4 (89.07) 4 (90.9) 6 50 (5.24) 05 (4.) 79 (7.05) 54.2 (6.07) 280 (.02) 00 (.8) 25 (2.80) 74 (6.85) 6.2 (79.8) 6.8 (8.) 6 00 (5.24) 05 (4.) 79 (7.05) 54.2 (6.07) 20 (2.60) 00 (.8) 25 (2.80) 74 (6.85) 5.2 (2.88) 5.8 (4.20) 6 600 (5.24) 05 (4.) 79 (7.05) 46. (5.76) 55 (.98) 00 (.8) 25 (2.80) 74 (6.85) 46.2 (0.85) 76.8 (69.) 8 50 (5.24) 05 (4.) 79 (7.05) 202.7 (7.98) 45 (.58) 00 (.8) 50 (.78) 94 (7.64) 50.0 (0.2) 50.6 (.55) 8 00 (5.24) 05 (4.) 79 (7.05) 202.7 (7.98) 80 (4.96) 00 (.8) 50 (.78) 94 (7.64) 74.8 (64.9) 75.4 (66.2) 0 50 (5.24) 05 (4.) 79 (7.05) 254.5 (0.02) 405 (5.94) 80 (4.96) 70 (4.57) 224 (8.82) 74.4 (64.02) 75.0 (65.5) 0 00 (5.24) 05 (4.) 79 (7.05) 254.5 (0.02) 455 (7.9) 80 (4.96) 70 (4.57) 224 (8.82) 06.4 (24.57) 07.0 (25.89) 2 50 (5.24) 05 (4.) 79 (7.05) 04.8 (2.00) 485 (9.09) 450 (7.72) 95 (5.55) 244 (9.6) 06. (24.5) 06.9 (25.67) 2 00 (5.24) 05 (4.) 79 (7.05) 04.8 (2.00) 520 (20.47) 450 (7.72) 95 (5.55) 244 (9.6) 5. (.56) 5.9 (4.88) ) For dual converter: specified weight + 2.80 kg (6.7 lb). /66 Siemens FI 0 204 US Edition

Siemens AG 204 Flow Measurement SITRANS FX00 a c b a c b H D D H l L d L d Sandwich version Sandwich version with pressure sensor Sandwich version EN Size Pressure Dimensions [mm (inch)] Weight [kg (lb)] rating DN PN a b c d D L H l Flowmeter Flowmeter (without (with pressure pressure sensor) sensor) 5 6... 00 (5.24) 05 (4.) 79 (7.05) 6 (0.6) 45 (.77) 65 (2.56) 265 (0.4) 44 (5.67).5 (7.72) 4. (9.04) 25 6... 00 (5.24) 05 (4.) 79 (7.05) 24 (0.94) 65 (2.56) 65 (2.56) 265 (0.4) 44 (5.67) 4. (9.48) 4.9 (0.80) 40 6... 00 (5.24) 05 (4.) 79 (7.05) 8 (.50) 82 (.2) 65 (2.56) 270 (0.6) 44 (5.67) 4.9 (0.80) 5.5 (2.) 50 6... 00 (5.24) 05 (4.) 79 (7.05) 50 (.97) 02 (4.02) 65 (2.56) 275 (0.8) 44 (5.67) 6 (.2) 6.6 (4.55) 80 6... 00 (5.24) 05 (4.) 79 (7.05) 74 (2.9) 5 (5.) 65 (2.56) 290 (.42) 55 (6.0) 8.2 (8.08) 8.8 (9.40) 00 6... 00 (5.24) 05 (4.) 79 (7.05) 97 (.82) 58 (6.22) 65 (2.56) 0 (2.20) 64 (6.46) 9.5 (20.94) 0. (22.27) Sandwich version ASME Size Pressure rating Dimensions [inch] Weight [lb] DN Class a b c d D L H l Flowmeter Flowmeter (without (with pressure pressure sensor) sensor) ½" 50, 00, 600 5.24 4. 7.05 0.6.77 2.56 0.4 5.67 7.72 9.04 " 50, 00, 600 5.24 4. 7.05 0.94 2.56 2.56 0.4 5.67 9.48 0.80 ½" 50, 00, 600 5.24 4. 7.05.50.2 2.56 0.6 5.67 0.80 2. 2" 50, 00, 600 5.24 4. 7.05.97 4.02 2.56 0.8 5.67.2 4.55 " 50, 00, 600 5.24 4. 7.05 2.9 5. 2.56.42 6.0 8.08 9.40 4" 50, 00, 600 5.24 4. 7.05.82 6.22 2.56 2.20 6.46 20.94 22.27 Siemens FI 0 204 US Edition /67

Flow Measurement Siemens AG 204 SITRANS FX00 Remote version Flanged version DN 5 25 40 50 80 00 50 200 250 00 ½" " ½" 2" " 4 " 6" 8" 0" 2" a [mm] 248 248 25 258 27 29 08 5 78 [inch] 9.77 9.77 9.97 0.2 0.8.5 2...9 4.9 b c d e f g h j k l m n p [mm] 40 Ø06 0 29 40 20 00 Ø5 Ø9 (4x) 60 80 44 04 [inch] 5.52 Ø4.8 2.2 8.6 5.52 4.7.94 Ø4.5 Ø0.6 (4x) 2.6.5 5.67 4.09 Sandwich version DN 5 25 40 50 80 00 ½" " ½" 2" " 4 " a [mm] 248 248 25 258 27 29 [inch] 9.77 9.77 9.97 0.2 0.8.5 b c d e f g h j k l m n p [mm] 40 Ø06 0 29 40 20 00 Ø5 Ø9 (4x) 60 80 44 04 [inch] 5.52 Ø4.8 2.2 8.6 5.52 4.7.94 Ø4.5 Ø0.6 (4x) 2.6.5 5.67 4.09 /68 Siemens FI 0 204 US Edition

Siemens AG 204 Flow Measurement SITRANS FX00 Flow tables Measuring Range Limits Water Size Q min Q max Q min Q max DN to EN 092- DN to ASME B6.5 EN 092- [m /h] EN 092- [m /h] ASME B6.5 [m /h] ASME B6.5 [m /h] 5 ½" 0.45 5.07 0.44 4.94 25 " 0.8.40 0.8.40 40 ½" 2.04 28.58 2.04 28.58 50 2".5 49.48.5 49.48 80 " 7.74 08.7 7.74 08.7 00 4".0 86.22.0 86.2 50 6" 0. 42.86 0. 42.86 200 8" 56.60 792.42 56.60 792.42 250 0" 90.48 266.8 90.48 266.8 00 2".4 89.8.4 89.8 Values based on water at 20 C (68 F) Air Size Q min Q max Q min Q max DN to EN 092- DN to ASME B6.5 EN 092- [m /h] EN 092- [m /h] ASME B6.5 [m /h] ASME B6.5 [m /h] 5 ½" 6.80 25. 6.72 24.70 25 " 0.20 8.4 0.20 8.4 40 ½" 25.5 26.6 25.5 26.6 50 2" 4.89 565.49 4.89 565.49 80 " 96.4 28.64 96.4 28.60 00 4" 65.9 2 28.27 65.9 2 28.27 50 6" 74.2 4 82.60 74.2 4 82.60 200 8" 702.95 9 056.8 702.95 9 056.8 250 0" 2.7 4 478.0 2.7 4 478.0 00 2" 62. 2 028.0 62. 2 028.0 Values based on air at 20 C (68 F) and.0 bar abs (4.7 psi abs ) Flow rate limits Product Nominal diameters Minimum flow rates Maximum flow rates to EN to ASME [m/s] [m/s] Liquids DN 5 DN 00 DN ½" DN 2" 0.5 x (998/) 0.5 ) 7 x (998/) 0.47 ) Gas, steam/vapor DN 5 DN 00 DN ½" DN 2" 6 x (.29/) 0.5 2) 7 x (998/) 0.47 ) = operating density [kg/m ] ) Minimum flow rate 0. m/s (0.984 ft/s), maximum flow rate 7 m/s (2 ft/s) 2) Minimum flow rate 2 m/s (6.6 ft/s) ) Maximum flow rate 80 m/s (262 ft/s); DN 5: 45 m/s (48 ft/s) and DN 25: 70 m/s (20 ft/s) Siemens FI 0 204 US Edition /69

Flow Measurement Siemens AG 204 SITRANS FX00 Measuring range saturated steam: to 7 bar Overpressure [bar].5 5.2 7 Density [kg/m³].498 2.4258.2765 4.672 Temperature [ C] 20.6 48.2 60.4 70.6 Flow [kg/h] min. max. min. max. min. max. min. max. DN to EN 092- DN to ASME B6.5 5 ½" 5.87 28.75 7.68 6.46 8.9 8.0 0.06 05.57 25 ".82 92.42 7.28 97.5 20.09 266.8 22.66 9.5 40 ½" 29.64 70.7 4. 792. 50.6 070.2 56.8 6.2 50 2" 5. 64.82 75.02 7.8 87.9 852.8 98. 256.6 80 " 2.4 405.8 64. 004.7 9 4058.4 25.9 56.8 00 4" 9.4 245.5 282.6 562.7 28.6 697. 70.09 8869.2 50 6" 47.56 5472.4 69.69 696 74.45 5 798 88.44 20 09 200 8" 82.9 0 279.0 20.6 2 970.0 96.5 29 675.0 574.9 7 74 250 0".9 6 4.0 920.9 5 22.0 222.5 47 49.0 257.7 60 7 00 2" 908. 2 866.0 2 789.8 5 00.0 242.4 68 899.0 656.6 87 60 Measuring range saturated steam: 0.5 to 20 bar Overpressure [bar] 0.5 4 7.5 20 Density [kg/m³] 5.8880 7.60297 9.702 0.5442 Temperature [ C] 86.2 98.5 208.7 25 Flow [kg/h] min. max. min. max. min. max. min. max. DN to EN 092- DN to ASME B6.5 5 ½" 2.78 49.7 6.5 92.6 20.2 26.04 22.89 267.2 25 " 26.9 479.46 0.6 69..87 758.69 6.04 858.62 40 ½" 67.5 878.2 76.72 250.7 84.9 295. 90.5 2557.7 50 2" 6.89 25.7 2.82 72.4 47.0 447 56.42 4428. 80 " 256.0 722.4 290.9 855.8 22.06 908.7 42.62 9699. 00 4" 49.9 2 28 499.9 4 0 55.8 5 608 588.69 6 666 50 6" 996.62 27 725 2.5 747 25.7 5 59.7 7 756 200 8" 872. 52 079 227. 59 64 254.9 66 49 2 505.2 70 92 250 0" 2992.7 8 254 400.7 95 764.6 06 80 4004.9 80 00 2" 446.5 20 920 499. 8 460 5467.5 54 20 5 86.5 64 660 /70 Siemens FI 0 204 US Edition

Siemens AG 204 Flow Measurement SITRANS FX00 Measuring range saturated steam: 5 to 00 psig Overpressure [psig] 5 50 75 00 Density [lb/ft³] 0.079 0.497 0.206 0.2569 Temperature [ F] 249.98 297.86 20.6 8.84 Flow [lb/h] min. max. min. max. min. max. min. max. DN to EN 092- DN to ASME B6.5 5 ½" 2.95 64.5 6.8.87 9.62 82.02 22.04 229.6 25 " 26.25 206.8 7.86 40. 44.5 585.06 49.59 78.09 40 ½" 65.8 829.6 94.92 726 0.68 246.7 24.2 2960.5 50 2".94 46. 64.4 2988 9.6 4062.9 25.2 525.6 80 " 249.57 46. 60 6545. 49.74 8899.4 47.45 227 00 4" 428.8 5405.7 68.5 246 72.2 5 29 80.06 9 29 50 6" 97.47 2 246 40.2 25 478 6.9 4 642 85.2 4 70 200 8" 824.8 2 004 262. 47 859 069. 65 072 447.2 82 092 250 0" 297.2 6 774 4207.7 76 508 4906.4 04 00 550.8 20 00 2" 426.8 5 40 6. 20 725.8 5 080 800.6 90 600 Measuring range saturated steam: 50 to 00 psig Overpressure [psig] 50 200 250 00 Density [lb/ft³] 0.627 0.468 0.575 0.6792 Temperature [ F] 66.08 88.04 406.22 422.06 Flow [lb/h] min. max. min. max. min. max. min. max. DN to EN 092- DN to ASME B6.5 5 ½" 27.79 24.2 5.86 48.47 4.94 52.66 52.04 607.2 25 " 58.9 042. 66.94 45. 74. 647.8 80.6 95.5 40 ½" 47.72 407.2 67.8 4702.8 85.76 527 202.5 5728 50 2" 255.75 7.9 290.56 84.9 2.6 9066.8 50 997 80 " 560.9 5 578 66.44 7 84 704.4 9 860 766.6 2 722 00 4" 962.54 26 766 09.5 0 64 20.4 4 24 7.2 7 24 50 6" 280.6 60 69 2477.4 69 42 2742. 77 07 2984 84 556 200 8" 4096. 900 465.6 0 400 550.7 45 20 5605.2 58 80 250 0" 6548. 82 090 749. 208 460 824. 22 40 8960.6 25 90 00 2" 950.2 264 460 0 805 02 760 959 7 50 04 68 770 Siemens FI 0 204 US Edition /7

Flow Measurement Siemens AG 204 Notes /72 Siemens FI 0 204 US Edition