USB3.0 for Active Optical Cable

Similar documents
USB3.0 For Active Optical Cable SPECIFICATIONS

USB3.0 For Active Optical Cable SPECIFICATIONS

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Security Plus Online Uninterruptible Power Supply

GB60S 60W Single Output General Purpose Series

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

Weatherproof Tubular Slip Ring Assembly

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

Industrial Power Supplies

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

RP40- _FR/ Package (4) CTRL Logic (3)

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Model Number Structure

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Load (2) Single or Dual

Solid State Relays contactor with Integrated Fuse Type RGC1F

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Packaging (1) Package

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

CHASSIS MOUNT DC-DC CONVERTERS 4:1 WIDE INPUT RANGE, 150 WATTS RAILWAY APPLICATIONS FWB(D)150 SERIES*

EATON 9315 UPS 200 TO 300 KVA Specifications

Features. Description. Table of Contents

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

YOUR PARTNER FOR IMPULSE EMC EMC PARTNER PRODUCT RANGES. Immunity Lightning Component Emission Automation

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Digital Time Switches

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

C B. Operating up to 5000m altitude 5 year product warranty Models

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

FEATURES. Input Voltage (VDC) 3.3

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Fiber Optic, Breakout cable, tight buffered, 900 microns

DC/DC Converter URB1D_LD-15W & URB1D_LD-20W Series

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Series AM5T-Z 5 Watt DC-DC Converter

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

CAN and Serial Instrumentation

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

Indoor Linear 50W Driver SI-CU WW

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Series AM1P-Z 1 Watt DC-DC Converter

4:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 87% Ultraminiature Open Frame SMD No Minimum Load Required

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Features and Benefits. Certifications

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

S24SP series 40W Single Output DC/DC Converter

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Surface mounting, flush mounting, and DIN track mounting

Linear Line Voltage LED Engine

Series AM2D-Z 2 Watt DC-DC Converter

RCD15W Series PART NUMBER STRUCTURE

KEPCO Will Point You In The Right Direction!

Linear Line Voltage LED Engine

STRIDER ESSENTIAL SERIES ST50F-ESB ST40F-ESB Power for everything you need

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A

SPECIFICATIONS FOR UPEC SMD TYPE LED

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

MPP10-48 S 05 W A - P T Series Name Input Output Output Input Pin Connection Remote On/Off Trim Voltage Quantity Voltage Range Option Options Option

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable

Three-Phase Soft Starters

CRegulatory. Compliance: UL and CE APPENDIX C IN THIS CHAPTER. Installation Instructions Installation Guidelines System Installation Techniques

Hand-held Fundus Camera (Model :HFC) Operating Manual

DC/DC Converter URA(B)_LD-15WR2 & URA(B)_LD-20WR2 Series

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Volition Fiber Optic Cable

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W peak output power

Volition. Fiber Optic Cable. 3Innovation

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Transcription:

USB3.0 for Active Optical Cable 1. Description 1. Basics: USB3.0 Active Optical Cable (AOC) speed up to 5 Gbps 2. Dimension of USB3.0 Type A male plug conforming requirements (Size: 56.1 x 8 x 16 mm). 3. It requires two cables to be connected into one adapter in order to operate well with USB 3.0 function. 4. There is no USB 2.0 function in this cable, thus it only support USB 3.0 function. ELII optical cable. 2. Features USB3.0 AOC can extend high speed transmission distance up to 100m (330ft) of USB3.0 compliant, extend High Speed USB3.0 to 100m (330ft) 850nm Laser Optical Transmission Technology 90 Ohm impedance, low RFI/EMI for sensitive environment Thin, light, all-in-one over mold dimension fits USB3.0 Type A male plug Plug and play, no software to be installed Supports OS windows system 7,8.1 Linux fedora 20 Scientific Linux 6.3 MAC OS 10.8.5 above - 1 - Electronic Links International, Inc.

3. Applications File system to file system Long Distance Communication Conference Room System High Speed Data Transfer PS: 1. Plug Device 1 into USB 3.0 Host PC or NB. 2. Bridge Device 2 and 3 by Device 4 3. Finally, plug in the DC Adapter(5V/2A) into Device 4. - 2 - Electronic Links International, Inc.

Absolute Maximum Ratings Electronic Links International, Inc. Parameter Symbol Minimum Maximum Unit Supply Voltage V CC 4.75 5.25 V Storage Temperature T st -10 70 C Operation Temperature T op 0 50 C Relative Humidity RH 0 80 % 4. Recommended Operating Conditions Parameter Symbol Minimum Typical Maximum Unit Supply Voltage V CC +4.75 +5.0 +5.25 V Center Wavelength Tx λ 850 nm Rx λ 850 Tx 20M 5G bps Data Rate Rx 20M 5G bps Ambient Temperature T A 0 +50 C 5. Electrical Power Supply Characteristics Parameter Symbol Minimum Typical Maximum Unit Supply Voltage V CC +4.75 +5.0 +5.25 V Supply Current I 40 50 60 ma Power Dissipation P 0.2 0.275 0.32 W Impedance Differential Tx Z TX 90 ohms Rx Z RX 90 ohms 6. Fiber Cable Specifications Parameter Value Cable Jacket material LSZH Color Orange Optical Fiber 50/125 Multimode Fiber Output Diameter 3.0mm Minimum Bending Radius 37.5mm Maximum Tensile Load 0.7GN / m² Net Weight 8g/meter - 3 - Electronic Links International, Inc.

7. USB AOC Plug Appearance Parameter Value Plug case material Plastic Color Black Plug dimension 56.1 x 8 x 16mm NOTES: 1. All dimensions in mm. 2. Tolerance (except cable length): XXXX =±5, XXX.x =±1, XX.x =±0.5 8. EMC Test EMI: FCC CLASS A (ICES-003) and CE CLASS A Standards Conditions EN 55 022 (CISPR22) CE (Conducted Emission) FCC; PART 15 SUBPART B RE (Radiated Emission) Meet Class A EN 61 000-3-2 (IEC 61000-3-2) Harmonics Meet Class A EN 61 000-3-2 (IEC 61000-3-3) Flickers Meet Class A EMS: CE STANDARDS (EN 55024) and CISPR24 EQUIVALENTS Standards Conditions EN 61 000-4-2: 2008 Electrostatic Discharge Immunity Meet Class B (Air: 8kV, Contact: 4kV) EN 61 000-4-3: 2010 Radiated RF E-Field (80 1000MHz) Meet Class A 3V/m (AM 80%, 1kHz) EN 61 000-4-4: 2012 Fast Transients (5kHz, 60sec) Meet Class B EN 61 000-4-5: 2005 Surge Transients Meet Class B EN 61 000-4-6: 2008 Conducted Susceptibility (CS) Meet Class A Radiated Susceptibility (RS) EN 61 000-4-8: 2009 Power Frequency Magnetic Field Meet Class A EN 61 000-4-11: 2004 Voltage Dips, Interruption & Variation Meet Class A - 4 - Electronic Links International, Inc.

9. Drawing Fiber print : Optical Cable OM3 50 /125 LSZH OFNR (UL) c(ul) 75 C E316737 (F.RoHS) MM/YY XXXXM Length L= 10M~100M +5% -0% USB3.0 A-plug connector define - 5 - Electronic Links International, Inc.

10. Ordering Ordering Part Number ELII-AOC-L-P-Y _ P = Plug Type A R = Receptacle Type A (Available Q2 2015) P = Plug Type A L = Length 010 = 10 meters Up to 100 = 100 Meters - 6 - Electronic Links International, Inc.

11. Package Fiber Winding inside diameter d=15.5cm±0.5cm (sponge diameter >15cm), Rubber cable ties *2 & Wire Tie *2 ( * Optional ) Carton size:470*340*300 mm - - Electronic Links International, Inc.