MONTAGE WELDED RESIDENTIAL ORNAMENTAL FENCE

Similar documents
RESIDENTIAL ORNAMENTAL STEEL FENCE

ORNAMENTAL STEEL FENCE

ORNAMENTAL STEEL FENCE

ORNAMENTAL ALUMINUM FENCE

MONTAGE PLUS SINGLE SWING STEEL ESTATE GATE SPECIFICATIONS

INDUSTRIAL GRADE ORNAMENTAL ALUMINUM FENCE

MONTAGE II SINGLE SWING STEEL ARCHED ESTATE GATES

ALUMINUM FENCE SYSTEMS 2000 RESIDENTIAL SERIES 4000 COMMERCIAL SERIES. KeyLinkOnline.com

SECTION METAL ATHLETIC SPORT LOCKERS

ALUMINUM. The Superior Alternative CLASSIC SERIES. All Aluminum Fence Supply Products are Manufactured in the United States of America

Table of Contents: Residential Aluminum Quick Reference Sheet Residential Aluminum Commercial Aluminum

ROUNDS SQUARES GALVONALL. Refer to construction specification & tables within this section for more details. GALVONALL

A S S E M B L Y I N S T R U C T I O N S

Ford Mustang Side Rocker Molding Installation Instructions Application: Ford Mustang

Mustang Billet Aluminum Pedal Cover Kit P/N R (Manual) and R (Automatic) Installation Instructions

Style 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date

RESIDENTIAL GRADE ORNAMENTAL ALUMINUM

SECTION FIRST RESPONDER SERIES HEAVY DUTY PERSONNEL LOCKERS DEBOURGH MFG. CO. 10/15/2013

Rittling Econoline Enclosures

Installation Instructions/Operation and Maintenance Manual. PS DOORS Contact Information. Website psdoors.com

Repeat procedure for both sides of U bar.

2018 FENCE CATALOG DECORATIVE ACCENTS LAWN & GARDEN

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

ROLLER GATES. Waterman Industries of Egypt. Roller gates are nominated for heavy duty service where large loads and sizes are going to be encountered.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

DRAGO. Corn Header Manual f HEADSIGHT.COM

3PC TONNEAU COVER WITH SPORTS BAR INSTALLATION INSTRUCTIONS

SECTION PIPE HANGERS AND SUPPORTS

AGCO. Corn Header Manual d HEADSIGHT.COM

FOLD N STORE. Table Tennis Table. Assembly Instructions Model DS, DS CONTACT INFO Hours.

STATE OF NORTH CAROLINA D DEPARTMENT OF ADMINISTRATION MARCH 20, 1995 PURCHASE AND CONTRACT DIVISION 7125-LM-2C November 9, 1989

Ford Mustang Rear Decklid Spoiler Kit. Installation Instructions

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

Installation Instructions/Operation and Maintenance Manual. PS DOORS Contact Information. Website psdoors.com

For the best in quality and durability, insist on Omaha Standard America s Standard In Truck Bodies

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

PLATFORM BODIES. Platform Bodies. Made in the USA VERSATILE DURABLE RUGGED

GERINGHOFF. Corn Header Manual f HEADSIGHT.COM

Size Box Qty. Item# Less Box Box

Part# Description Q'TY

JK HD Skid Plate for Rear Falcon Shocks

DUO-FORCE PRO. For pro-force fl3430. By FORCE Unlimited. FORCE Unlimited 1504 S. Frederick Avenue Oelwein, IA (319)

PRORAC CONTRACTOR SERIES UNIVERSIAL STEEL ECONO TRUCK RACK INSTALLATION INSTRUCTIONS

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

2013 Mustang Chin Splitter

UNIVERSAL REMOVABLE REAR CROSSBAR CONVERSION INSTRUCTIONS FOR HAULER RACK II & SERVICE BODY SERIES RACKS

TUSCANY IMPORTANT!!!

Ford Fabricated Steel Products

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

Table Tennis Table. Assembly Instructions Model CONTACT INFO. Hours

SECTION SWING CHECK VALVES

OWNER S MANUAL. 2 Axle

Before installing your Roush Performance Product(s), read through the entire installation procedure and check to make sure all items are present.

TUFCOTE 3.3 PR HIGH SOLIDS FAST DRY ALKYD PRIMER (formerly DuPont 681 FD )

CORN HEADER MANUAL: CNH PRE-2012

Air Curtain. Installation, Operating and Maintenance Instructions

Grinnell Grooved Fire Protection Products Grooved Fittings

2013+ Focus ST Focus ROUSH Exhaust Kit

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

FLEX MOUNT KIT INSTALLATION INSTRUCTIONS FMK-SW (Swing Gates) & FMK-SL (Sliding Gates)

We Make Good Neighbors!

Locker Specifiers guide

ROUSH Front Splitter Kit

Product Specifications for Aluminum Vertical Break Switches

JK HD Skid Plate for Rear Falcon Shocks

Strainer and Check Valves

INSTRUCTION MANUAL L WIND CONE

FOLD N STORE. Table Tennis Table. Assembly Instructions Model , DS, DS CONTACT INFO Hours.

Installation, Operating and Maintenance instructions for Hydro-Air pumps

Series 3500 Externally Pressurized Expansion Joints Catalog 574 H

Blank Size AEW BEW CEW DEW AA A B C D E AAL AL BL CL AE BE CE DE HA HB HC HD /4-20, 10-24, /4-20, 5/ /8-16 LA LB LC LD LE

VAN LADDER RACK FOR ULR-E INSTRUCTIONS P/N ULRDD-1

FIG Gruvlok Flanges

Product Specifications for Phase Over Phase GOABS(r)

Construct Compressed Air Building Near Bldg SECTION OVERHEAD COILING DOORS 07/07

ROUSH FUEL SYSTEM UPGRADE CURRENT FORD MUSTANG 5.0L

9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS

Dodge Ram 1500, Quad/Reg. Cab, w/6.4ft. & 8ft. Bed, 2 & 4 WD. For updates see PRODUCT SUPPORT tab at

Installation Guide GSXR 600/750 Full-Exhaust Kit

Operator s Manual. Twin Rear Bagger For FastAttach Compatible Lawn Tractors

INSTALLATION AND OPERATION MANUAL

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER C (GUN METAL GRAY FINISH) 2016 VW Jetta 1.

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Buhler Versatile 23XX/24XX, Versatile 9X80, and New Holland Versatile 9X8X SmarTrax MD Installation Manual. P/N Rev A 04/16 E23635

equalizersystems.com. Installation and Operation Guide October Revision- November 2016

Ford F150 Center and Side Stripe Kit(s) Part # Refer to Tables on pages 2 & 3

Specification for Remanufacture Alstom Model 5 Switch Machine

TYPICAL SPECIFICATION ECP Steel Pier PPB-300 Utility Bracket System

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER:

ORNAMENTAL FENCE. (Gate Fittings Section) Call for pricing

TONNEAU COVER INSTALLATION INSTRUCTION. Toyota Hilux 407L

INSTALLATION INSTRUCTIONS UNDERMOUNT SINKS

Operating and Installation Instructions

Cabinet Hardware LIST PRICES. effective January 1, 2008

Albuquerque Public Schools Industrial Fencing Material and Installation on Demand BID #18-059KN. Bid Tabulation Abstract

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

ROUSH Performance Air Induction Kit Pt # Installation Instructions

INSTALLATION INSTRUCTIONS

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Transcription:

MONTAGE WELDED RESIDENTIAL ORNAMENTAL FENCE TYPICAL PANEL DRAWING (Classic Style shown; Genesis, Majestic, Warrior, Crescent and Gemini also available) MONTAGE * Nominal Montage ATF Rail 15/16 W x 1-1/4 H x 94 L x 14 Ga. Picket (5/8 Square x 18 Ga.) Varies With Height Standard Heights 3, 3,, 3-½,, 4-1/2, 4-½,, Post (2 Square x 16 Ga.) 21 Min. Footing Depth 3-3/4 Typical (4 Air Gap) 3 Typical (3 Air Gap) * Refer to Construction Specification Table for recommended (Post Spacing by Bracket Type) E-Coat PROTECTION UNIQUE PROFUSION WELDING PROCESS PATENT D466,620 6,811,145 7,071,439 ATF RACKABLE DESIGN PATENT D466,621 7,071,439 AUTOMATICALLY FUSION WELDED AT ALL INTERSECTIONS NO EPOSED WELDS - VIRTUALLY SEAMLESS APPEARANCE GOOD NEIGHBOR PROFILE - SAME ON BOTH SIDES CONSISTENTLY HIGH QUALITY LEVEL - EVERY PANEL ZINC-PHOSPHATIZED GALVANIZED STEEL BASE MATERIAL Page 2-1

MONTAGE PANELS 2-Rail (Standard) 4 Air Gap CLASSIC GENESIS MAJESTIC WARRIOR CRESCENT (Not Rackable) () PALLET PANEL HEIGHT ITEM NUMBER PANEL WEIGHT QUANTITY 234 30 H 2 33 H 246 36 H 258 43 STYLE SELECTION = CLASSIC = GENESIS = MAJESTIC = WARRIOR = CRESCENT = * C G M W L = COLOR SELECTION N = BRONZE GEMINI = IN 4 AIR GAP MAJ, CLS, GEN/BLK & MAJ/BRZ MAJ, CLS, GEN/BLK ( Nominal) 94 Actual Panel Width 5/8 Sq x 18 Ga. Picket = (21 - Pickets per Panel) MAJESTIC 3 Air Gap GEMINI (Not Rackable) () PALLET PANEL HEIGHT ITEM NUMBER PANEL WEIGHT QUANTITY H H 234-3 2-3 246-3 STYLE SELECTION = * = COLOR SELECTION MAJESTIC = M GEMINI = H N = BRONZE CLASSIC = IN 3 AIR GAP GENESIS = IN 3 AIR GAP WARRIOR = IN 3 AIR GAP CRESCENT = IN 3 AIR GAP * Non-Stocking panel styles/colors must be purchased in full pallet quantities. * Genesis panels in both Black and Bronze are packaged with (Black) 5/8 Sq picket plugs. 34 38 44 ( Nominal) 94 Actual Panel Width 5/8 Sq x 18 Ga. Picket = (26 - Pickets per Panel) Page 2-2

MONTAGE PANELS 2-Rail (Flush Bottom) 4 Air Gap MONTAGE CLASSIC GENESIS MAJESTIC WARRIOR CRESCENT (Not Rackable) () PALLET PANEL HEIGHT ITEM NUMBER PANEL WEIGHT QUANTITY 234F 30 H 2F 33 H 246F 36 H 258F STYLE SELECTION = CLASSIC = GENESIS = MAJESTIC = WARRIOR = CRESCENT = * C G M W L = COLOR SELECTION N = BRONZE GEMINI = IN 4 AIR GAP 43 ( Nominal) 94 Actual Panel Width 5/8 Sq x 18 Ga. Picket = (21 - Pickets per Panel) MAJESTIC 3 Air Gap GEMINI (Not Rackable) () PALLET PANEL HEIGHT ITEM NUMBER PANEL WEIGHT QUANTITY 234F-3 34 H 2F-3 38 H 246F-3 44 STYLE SELECTION = * = COLOR SELECTION MAJESTIC = M GEMINI = H N = BRONZE CLASSIC = IN 3 AIR GAP GENESIS = IN 3 AIR GAP WARRIOR = IN 3 AIR GAP CRESCENT = IN 3 AIR GAP * Non-Stocking panel styles/colors must be purchased in full pallet quantities. * Genesis panels in both Black and Bronze are packaged with (Black) 5/8 Sq picket plugs. ( Nominal) 94 Actual Panel Width 5/8 Sq x 18 Ga. Picket = (26 - Pickets per Panel) Page 2-3

MONTAGE PANELS 3-Rail (Standard) 4 Air Gap CLASSIC GENESIS MAJESTIC WARRIOR CRESCENT (Not Rackable) () PALLET PANEL HEIGHT ITEM NUMBER PANEL WEIGHT QUANTITY 334 35 H 3 39 H 346 42 H 358 49 H 370 55 STYLE SELECTION = * = COLOR SELECTION CLASSIC = C GENESIS = G N = BRONZE MAJESTIC = M WARRIOR = W CRESCENT = L GEMINI = IN 4 AIR GAP MAJ, CLS, GEN/BLK MAJ, CLS, GEN/BLK MAJ, CLS, GEN, WAR, CRE/BLK & MAJ, GEN/BRZ MAJ, CLS, GEN, WAR/BLK & MAJ, CLS/BRZ MAJ, CLS, GEN, WAR/BLK & CLS, GEN/BRZ ( Nominal) 94 Actual Panel Width 5/8 Sq x 18 Ga. Picket = (21 - Pickets per Panel) 3 Air Gap CLASSIC GENESIS MAJESTIC GEMINI (Not Rackable) () PALLET PANEL HEIGHT ITEM NUMBER PANEL WEIGHT QUANTITY 334-3 H 3-3 44 H 346-3 50 H 358-3 55 H 370-3 62 STYLE SELECTION = * = COLOR SELECTION CLASSIC = C GENESIS = G N = BRONZE MAJESTIC = M GEMINI = H WARRIOR = IN 3 AIR GAP CRESCENT = IN 3 AIR GAP * Non-Stocking panel styles/colors must be purchased in full pallet quantities. * Genesis panels in both Black and Bronze are packaged with (Black) 5/8 Sq picket plugs. MAJ, CLS, GEN/BLK MAJ, CLS/BLK MAJ, CLS/BLK ( Nominal) 94 Actual Panel Width 5/8 Sq x 18 Ga. Picket = (26 - Pickets per Panel) Page 2-4

MONTAGE PANELS 3-Rail (Flush Bottom) 4 Air Gap CLASSIC GENESIS MAJESTIC WARRIOR CRESCENT MONTAGE (Not Rackable) () PALLET PANEL HEIGHT ITEM NUMBER PANEL WEIGHT QUANTITY 334F 35 H 3F 39 H 346F 42 4-1/2 H R M 354F 48 (ONLY AVAILABLE IN MAJ) BLK H 358F 49 MAJ, CLS, GEN/BLK H 370F 55 MAJ, CLS/BLK STYLE SELECTION = * = COLOR SELECTION ( Nominal) 94 Actual Panel Width CLASSIC = C 5/8 Sq x 18 Ga. Picket = (21 - Pickets per Panel) GENESIS = G N = BRONZE MAJESTIC = M WARRIOR = W CRESCENT = L GEMINI = IN 4 AIR GAP 3 Air Gap CLASSIC GENESIS MAJESTIC GEMINI (Not Rackable) () PALLET PANEL HEIGHT ITEM NUMBER PANEL WEIGHT QUANTITY 334F-3 H 3F-3 44 H 346F-3 50 4-1/2 H R M 354F-3 55 (ONLY AVAILABLE IN MAJ) H 358F-3 56 H 370F-3 63 STYLE SELECTION = * = COLOR SELECTION ( Nominal) 94 Actual Panel Width CLASSIC = C 5/8 Sq x 18 Ga. Picket = (26 - Pickets per Panel) GENESIS = G N = BRONZE MAJESTIC = M GEMINI = H WARRIOR = IN 3 AIR GAP CRESCENT = IN 3 AIR GAP * Non-Stocking panel styles/colors must be purchased in full pallet quantities. * Genesis panels in both Black and Bronze are packaged with (Black) 5/8 Sq picket plugs. Page 2-5

MONTAGE BRACKETS ITEM DESCRIPTION Montage Universal Boulevard Bracket Montage Line Bracket Montage Flat Mount Bracket BLACK PART NO. BLACK DEALER PRICE BRONZE PART NO. COLOR DEALER PRICE BB102 BN102 2 150.27 Made from high strength stainless steel. Packaged in polybag with #10 x 3/4 self-drilling screws, 1/4 x 1-1/2 carriage bolts and 1/4 flange nuts. Works universally for lines, ends, and corners. Packaged 2 per bag. MUST BE ORDERED IN BAG QUANTITIES. LINE CORNER END BB104 BN104 2 120.47 Made from high strength stainless steel. Used as boulevard bracket around a 2 post to join two adjacent panels in line. Packaged in polybag with #10 x 3/4 self-drilling screws, 1/4 x 1-1/2 carriage bolts and 1/4 flange nuts. Packaged 2 per bag. MUST BE ORDERED IN BAG QUANTITIES. BB105 BN105 2 300.15 Made from high strength stainless steel. Can be used to attach panels to walls, wood posts, etc. Packaged in polybag with #14 x 3/4 self-drilling screws, 1/4 x 1-1/2 carriage bolts and 1/4 flange nuts. Packaged 2 per bag. MUST BE ORDERED IN BAG QUANTITIES. BAG QTY BO QTY WT EA. Montage Swivel Bracket BB106 BN106 2 120.20 Heavy-duty cast aluminum. For oblique angles. Packaged in polybag with #10 x 3/4 self-drilling screws and #10 x 5/8 flat head phillips screw. Packaged 2 per bag. MUST BE ORDERED IN BAG QUANTITIES. ADORNMENTS ITEM DESCRIPTION BLACK PART NO. DEALER PRICE PART NUMBER BRONZE PART NO. DEALER PRICE SIZE UNIT OF MEASURE WT EA. Quad-Flare AB301 AN301 5/8 Ea..2 Fits atop 5/8 square pickets (press-fit). Heavy-duty cast aluminum. The four-sided flare design supports the popular traditional look when added to Genesis style panels (21 required per panel on standard 4 Air Gap spacing; 26 required per panel on condensed 3 Air Gap spacing). Triad AB302 AN302 5/8 Ea..2 Fits atop 5/8 square pickets (press-fit). Heavy-duty cast aluminum. Three distinct tips reflect the strong look of a barbed spear when added to Genesis style panels (21 required per panel on standard 4 Air Gap spacing; 26 required per panel on condensed 3 Air Gap spacing). Serpentine Scroll HB059 HN059 - - - - Ea..75 Fits onto the face of 5/8 square pickets. Die cast aluminum. Can be mounted in a line between the top rails of 3-rail panels or grouped in Arched Swing Gates. Furnished with #10 x 3/4 self-drilling screws. (11 required per panel). Not available for 3 Air Gap spacing. Butterfly Scroll Double Ring HB058 HN058 - - - - Ea..2 Fits onto the face of 5/8 square pickets. Die cast aluminum. Can be mounted in a line between the top rails of 3-rail panels or grouped in Arched Swing Gates. Furnished with #10 x 3/4 self-drilling screws. (11 required per panel). Not available for 3 Air Gap spacing. AB102 AN102 (N/S) - - - - Ea..7 Fits onto the face of 5/8 square pickets. Die cast aluminum. Can be mounted in a line between the top rails of 3-rail panels to give the look of ornamental circle. Furnished with #14 x 3/4 self-drilling screws. Not available for 3 Air Gap spacing. Corona Picket Plug AB103 AN103 (N/S) - - - - Ea..35 Fits onto face of 5/8 square pickets. Pressed steel ring. Can be mounted in a line between the top rails of 3-rail panels to give the look of ornamental circles (11 required per panel). Includes two (2) #10 x 1/2 self-drilling screws. Not available for 3 Air Gap spacing. AB502 - - - - 5/8 21/Bag.06 5/8 plug for flat top pickets. SOLD IN BAG QUANTITY ONLY. N/S = Non Stock Page 2-6

AMERISTAR RIS AMERISTAR RISTAR RIS RISTAR AMERISTAR MER AMERISTAR PRIMER ZINC PRIMER ZINC PRIMER MONTAGE MONTAGE ITEM DESCRIPTION Self-Drilling Screws BLACK PART NO. FASTENERS PART NUMBER / COLOR BRONZE PART NO. DEALER PRICE HB524P-50 HN524P-50 #14 3/4 50/Bag.6 Stainless steel hex head self-drilling screws for brackets and adornments. SIZE UNIT OF MEASURE WT EA. MONTAGE Self-Drilling Screws HB539P-50 HN539P-50 #10 x 3/4 50/Bag.6 Stainless steel hex head self-drilling screws for brackets and adornments. Phillips Head Screws H519P - - - - - #10 x 5/8 Ea..005 Stainless steel flat head screw for setting angle on Montage swivel bracket. Carriage Bolts Flange Nuts HB511P-20 HN511P-20 1/4 x 1-1/2 Stainless steel carriage bolts for brackets. 20/Bag HB541P-20 HN541P-20 1/4 20/Bag.2 1/4 Stainless steel flange nuts for brackets..5 CUSTOM FINISHES ITEM DESCRIPTION BLACK BLACK DEALER PART NO. PRICE COLOR BRONZE PART NO. DEALER PRICE WEIGHT EACH Paint Pen PB100 PN100.5 AMERISTAR PB100 BLACK Custom finishes in the two standard Montage Fence colors. Zinc-Rich Paint Pen AMERISTAR PZ100 ZINC PZ100.5 Priming required for cut steel edges prior to application of Ameristar Custom Finishes. NOTE: All cut rail ends must be seal coated with Zinc Rich Primer and Ameristar s custom touch-up paint or the warranty is void. Spray Paint FB100 FN100 1.1 Custom finishes in the two standard Montage Fence colors. Zinc-Rich Primer FZ100 1.1 Ideal for priming cut steel edges of Montage Fence components prior to applying the appropriate custom finish color. NOTE: All cut rail ends must be seal coated with Zinc Rich Primer and Ameristar s custom touch-up paint or the warranty is void. Page 2-7

MONTAGE POSTS NOTE: In location subject to freezing, where posts are grouted into core-drilled holes, a 1/4 diameter hole should be drilled in the post approximately 1/2 above elevation to allow for drainage of built-up ground water. The drilled hole must be wiped clean and dry before applying Ameristar zinc primer and color finish. = COLOR SELECTION N = BRONZE W = WHITE S = SAND Post Ga. / Wall Post Catalog Price Catalog Price Post Diameter Thickness Length Item Number (Black) (Color) Weight -9 WP 20057 8-3 WP 20063 9 2 SQ. (STEEL) 16 GA. (RESIDENTIAL) -9-9 -9 WP 20069 WP 20081 WP 20093 10 11 13-9 WP 20105 14 WP 25072 12 2-1/2 SQ. (STEEL) 16 GA. (RES/COM) 9 WP 25084 WP 25096 WP 25108 14 16 18 POST BASES = COLOR SELECTION N = BRONZE W = WHITE S = SAND Catalog Price Catalog Price Base Post Size Base Size Drill Holes Item Number (Black) (Color) Weight Fits 2 SQ. Steel Post 5 x 5 9/16 B 205 3 Page 2-8

MONTAGE POST CAPS = COLOR SELECTION N = BRONZE W = WHITE S = SAND MONTAGE Catalog Price Catalog Price Cap Cap Type Cap Style Size Item Number (Black) (Color) Weight STEEL 1-3/4 SQ. A 505 0.1 STANDARD FLAT CAP 2 SQ. 2-1/2 SQ. A 506 A 507 0.2 0.3 ALUMINUM 2 SQ. H 508R 0.7 BALL CAP 2-1/2 SQ. A 513 0.7 Page 2-9

Montage Residential - Steel Ornamental Fence System - Fusion Welded and Rackable CONSTRUCTION SPECIFICATION - SECTION 32 31 00 PART 1 GENERAL 1.01 WORK INCLUDED The contractor shall provide all labor, materials and appurtenances necessary for installation of the welded ornamental steel fence system defined herein at (specify project site). 1.02 RELATED WORK Section - Earthwork Section - Concrete 1.03 SYSTEM DESCRIPTION The manufacturer shall supply a total fence system of (specify Montage standard picket space or Montage Pool, Pet & Play 3 air space) Welded and Rakeable (ATF All Terrain Flexibility) Ornamental Steel, (for standard picket space, specify Classic, Majestic, Genesis, Warrior, Crescent ; for 3 air-space specify Classic, Majestic, Genesis, or Gemini ) design. The system shall include all components (i.e., panels, posts, gates and hardware) required. 1.04 QUALITY ASSURANCE The contractor shall provide laborers and supervisors who are thoroughly familiar with the type of construction involved and materials and techniques specified. 1.05 REFERENCES ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy Coated (Galvannealed) by the Hot-Dip Process. ASTM B117 - Practice for Operating Salt-Spray (Fog) Apparatus. ASTM D523 - Test Method for Specular Gloss. ASTM D714 - Test Method for Evaluating Degree of Blistering in Paint. ASTM D822 - Practice for Conducting Tests on Paint and Related Coatings and Materials using Filtered Open-Flame Carbon-Arc Light and Water Exposure Apparatus. ASTM D1654 - Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments. ASTM D2244 - Test Method for Calculation of Color Differences from Instrumentally Measured Color Coordinates. ASTM D2794 - Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact). ASTM D3359 - Test Method for Measuring Adhesion by Tape Test. ASTM F28 Ornamental Fences Employing Galvanized Steel Tubular Pickets. 1.06 SUBMITTAL The manufacturer s literature shall be submitted prior to installation. 1.07 PRODUCT HANDLING AND STORAGE Upon receipt at the job site, all materials shall be checked to ensure that no damage occurred during shipping or handling. Materials shall be stored in such a manner to ensure proper ventilation and drainage, and to protect against damage, weather, vandalism and theft. PART 2 - MATERIALS 2.01 MANUFACTURER The fence system shall conform to (specify Montage standard picket space or Montage Pool, Pet & Play 3 air space) Welded and Rakeable (ATF All Terrain Flexibility) Ornamental Steel, (for standard picket space, specify Classic, Majestic, Genesis, Warrior, Crescent ; for 3 air-space specify Classic, Majestic, Genesis, or Gemini ) design, (specify extended picket or flush) bottom rail treatment, (specify 2-Rail or 3-Rail) style manufactured by Ameristar Fence Products, Inc., in Tulsa, Oklahoma. 2.02 MATERIAL A. Steel material for fence panels and posts shall conform to the requirements of ASTM A653/A653M, with a minimum yield strength of 45,000 psi (310 MPa) and a minimum zinc (hot-dip galvanized) coating weight of 0.60 oz/ ft2 (184 g/m2), Coating Designation G-60. A minimum of 62% of the steel material shall be derived from scrap metal. B. Material for pickets shall be 5/8 square x 18 Ga. tubing. The rails shall be steel channel, 1.25 x 0.925 x 14 Ga. Picket holes in the rail shall be spaced (specify 4.334 o.c. for standard picket space or 3.500 o.c. for 3 air space). Fence posts shall be a minimum of 2 square x 16 Ga. Gate posts shall meet the minimum requirements of Table 1. 2.03 FABRICATION A. Pickets, rails and posts shall be pre-cut to specified lengths. Rails shall be pre-punched to accept pickets. B. Pickets shall be inserted into the pre-punched holes in the rails and shall be aligned to standard spacing using a specially calibrated alignment fixture. The aligned pickets and rails shall be joined at each picket-to-rail intersection by Ameristar s proprietary fusion welding process, thus completing the rigid panel assembly (Note: The process produces a virtually seamless, spatter-free good-neighbor appearance, equally attractive from either side of the panel). C. The manufactured panels and posts shall be subjected to an inline electrode position coating (E-Coat) process consisting of a multi-stage pretreatment/wash (with zinc phosphate), followed by a duplex application of an epoxy primer and an acrylic topcoat. The minimum cumulative coating thickness of epoxy and acrylic shall be 2 mils (0.058 mm). The color shall be (specify Black or Bronze). The coated panels and posts shall be capable of meeting the performance requirements for each quality characteristic shown in Table 2 (Note: The requirements in Table 2 meet or exceed the coating performance criteria of ASTM F28). D. The manufactured fence system shall be capable of meeting the vertical load, horizontal load, and infill performance requirements for Industrial weight fences under ASTM F28. E. Gates shall be fabricated using welded ornamental panel material and gate ends having a 1-1/4 square cross-sectional size. All rail and upright intersections shall be joined by welding. All picket and rail intersections shall also be joined by welding. PART 3 - EECUTION 3.01 P REPARATION All new installation shall be laid out by the contractor in accordance with the construction plans. 3.02 FENCE INSTALLATION Fence post shall be spaced according to Table 3, plus or minus ½. For installations that must be raked to follow sloping grades, the post spacing dimension must be measured along the grade. Fence panels shall be attached to posts with brackets supplied by the manufacturer. The Earthwork and Concrete sections of this specification shall govern material requirements for the concrete footer. 3.03 FENCE INSTALLATION MAINTENANCE When cutting/drilling rails or posts adhere to the following steps to seal the exposed steel surfaces; 1) Remove all metal shavings from cut area. 2) Apply zinc-rich primer to thoroughly cover cut edge and/or drilled hole; let dry. 3) Apply 2 coats of custom finish paint matching fence color. Failure to seal exposed surfaces per steps 1-3 above will negate warranty. Ameristar spray cans or paint pens shall be used to prime and finish exposed surfaces; it is recommended that paint pens be used to prevent overspray. Use of non-ameristar parts or components will negate the manufactures warranty. 3.04 GATE INSTALLATION Gate posts shall be spaced according to the manufacturers gate drawings, dependent on standard out-to-out gate leaf dimensions and gate hardware selected. Type and quantity of gate hinges shall be based on the application; weight, height, and number of gate cycles. The manufacturers gate drawings shall identify the necessary gate hardware required for the application. Gate hardware shall be provided by the manufacturer of the gate and shall be installed per manufacturer s recommendations. 3.05 CLEANING The contractor shall clean the jobsite of excess materials; post-hole excavations shall be scattered uniformly away from posts. 1555 N. MINGO RD. TULSA, OKLAHOMA 74116 www.ameristarfence.com Page 2-10

Montage Residential - Steel Ornamental Fence System - Fusion Welded and Rackable CONSTRUCTION SPECIFICATION - SECTION 32 31 00 Gate Opening Table 1 Minimum Sizes for Montage Gate Post Up To & Including Gate Height Over, Up To & Including MONTAGE Up To & Including 2 x 16 Ga. 2 x 16 Ga. Over, Up To & Including 2 x 16 Ga. 2-1/2 x 16 Ga. Quality Characteristics Table 2 Coating Performance Requirements ASTM Test Performance Requirements Method Adhesion Corrosion Resistance D3359 Method B B117, D714 & D1654 Adhesion (Retention of Coating) over 90% of test area (Tape and knife test). Corrosion Resistance over 1,000 hours (Scribed per D1654; failure mode is accumulation of 1/8 coating loss from scribe or medium #8 blisters). Impact Resistance D2794 Impact Resistance over 60 inch lb. (Forward impact using 0.625 ball). Weathering Resistance D822, D2244, D523 (60 Method) Weathering Resistance over 1,000 hours (Failure mode is 60% loss of gloss or color variance of more than 3 delta-e color units). Table 3 Montage - Post Spacing By Bracket Type Span For CLASSIC, GENESIS, MAJESTIC, WARRIOR, CRESCENT, GEMINI Nominal (94 Rail) Post Size 2 2 2 2 Bracket Type Montage Universal (BB102) Montage Line Boulevard (BB104) Montage Flat Mount (BB105) Montage Swivel (BB106) Post Settings ± ½ O.C. 96-3/4 96-3/4 96-3/4 96-3/4 * Note: When using BB 106 swivel brackets on either or both ends of a panel installation, care must be taken to ensure the spacing between post and adjoining pickets meets applicable codes. This will require trimming one or both ends of the panel. Page 2-11

MONTAGE / MONTAGE PLUS WELDED ORNAMENTAL FENCE WARRANTY AMERISTAR Montage and Montage Plus Welded Ornamental Fences are manufactured from the highest quality materials by skilled craftsmen to meet the highest standards of workmanship in the industry. Galvanized steel framework is subjected to a multi-stage pretreatment/wash (with zinc phosphate), followed by a duplex cathodic electrocoat system consisting of an epoxy primer, which significantly increases corrosion protection, and an acrylic liquid topcoat, which provides the protection necessary to withstand adverse weathering effects. The electrocoated surface on all Montage and Montage Plus Welded Ornamental panels, posts, and gates is guaranteed under normal and intended usage, against cracking, peeling, chipping, blistering or corroding commencing with the original purchase date and extending according to the applications defined in the table below. Normal and intended usage does not include physical damage, abrasion, or heavy salt spray exposure to the protective coating. The following acts and/or omissions will void the subject warranty: Damage to the product caused by the property owner by use of landscape, gardening equipment, chemicals that may cause damage, and/or water sprinklers with high mineral content; Damage caused by adhesion of chicken wire or other similar substance to the product; Damage caused by allowing plant life of any sort to grow directly upon or in contact with any portion of the product or sap from trees; Any alteration to the product itself by the property owner including any on-site cutting or welding; and/or, Failure to follow any and all maintenance instructions provided by AMERISTAR at the time of sale to the original purchaser even if these instructions are not forwarded to the ultimate claimant under this warranty. When cutting Montage rails immediately seal the exposed surfaces by 1) Removing all metal shavings from cut area 2) Apply zinc-rich primer to thoroughly cover cut edge and drilled hole; let dry 3) Apply 2 coats of custom finish spray paint matching fence color. Failure to seal exposed surfaces per steps 1-3 above will negate warranty. If contractor uses non Ameristar parts/components this will negate the warranty. AMERISTAR Montage and Montage Plus Welded Ornamental Fences are also guaranteed for the same period of time against defects in workmanship or materials. Should any Montage or Montage Plus Welded Ornamental panel or post manufactured by Ameristar Fence Product fail in accordance with any of the above conditions, Ameristar Fence Products warrants to the original purchaser their redemption through replacement, renewal or issuance of a pro-rated credit. The choice of redemption method is solely at the discretion of Ameristar. If the pro-rated alternative is chosen, the amount will be based on the original cost of materials at the date of purchase multiplied by the appropriate time and exposure factor from the table below: Application Length of Warranty Fence Installations 0 to 1 Mile from Salt Water Coast Line 5 Years Fence Installations 1 to 10 Miles from Salt Water Coast Line 10 Years Fence Installations Over 10 Miles from Salt Water Coast Line 20 Years Note: Regardless of Location and Years in Service, evidence of historical salt spray exposure shall be considered as grounds to void any warranty obligatons. Notice of failure under the conditions of this waranty shall be sent to Ameristar Fence Products or its authorized representative, in writing, together with proof of purchase and shall specify the nature of the defect and when it was first observed as well as photographs of current site conditions. Should the fence be improperly installed, Ameristar Fence Products shall not be responsible for guaranteed performance or appearance of the material. Neither does this guarantee apply when failure or damage is due to improper use or application, abuse or misuse, salt spray exposure (see Table and Note), vandalism, or acts of God. Ameristar Fence Products reserves the right to inspect the material to determine validity of the claim. Upon acceptance of the claim by Ameristar Fence Products or its authorized representative, redemption by replacement, renewal or issuance of a pro-rated credit shall be made by Ameristar Fence Products. Reimbursement for the cost of removal of existing material and the freight and installation of replacement material is not included in the guarantee, nor will Ameristar Fence Products provide those services. The above constitutes the complete warranty by the manufacturer. No other agreement, written or implied, is valid. Ameristar Fence Products does not authorize any other person or agent to make any other express warranties. Ameristar Fence Products neither assumes nor authorizes any other person or agent to assume any other liability in connection with the Montage and Montage Plus Welded Ornamental Fence System. PURCHASE DATE DEALER SIGNATURE 1555 N. MINGO RD. TULSA, OKLAHOMA 74116 Page 2-12

WELDED GATES MONTAGE GATE SPECIFICATIONS STANDARD ARCHED (3.- Openings) Gate Ends: 1-1/4 Sq. (16 Ga.) Steel Gate Ends: 1-1/4 Sq. (16 Ga.) Steel Rails: 15/16 W x 1-1/4 H (14 Ga.) Rails: 15/16 W x 1-1/4 H (14 Ga.) Pickets: 5/8 Sq. (18 Ga.) Pickets: 5/8 Sq. (18 Ga.) All component intersections are welded for greater strength GATE DRAWING DIMENSIONAL FORMAT 3-3/4 3-3/4 3-3/4 s P d s Order 1 Leaf For Single Swing Opening Order 2 Leaves For Double Swing Opening Order 1 Leaf For Single Swing Opening (Available only as single) W = Outside To Outside Width of Finished Gate Leaf H = Height; HC = Hinge Clearance; LC = Latch Clearance; P s = Gate Post Spacing (Inside-To-Inside) for Single Gate; P d = Gate Post Spacing (Inside-To-Inside) for Double Gate See Montage Specification for Montage Gate Post Recommendation GATE OPENING W = LEAF WIDTH D&D SINGLE GATE KIT # D&D SINGLE POOL GATE KIT #DSKP KITS & POST INTERSPACES FOR MONTAGE ATF SINGLE SWING WELDED STEEL GATES HC LC P s HC LC P s 1-1/8 3/4 38-3/8 46-7/8 64-3/8 72-7/8 81-5/8 98-3/8 1-1/8 3/4 38-3/8 46-7/8 64-3/8 72-7/8 81-5/8 98-3/8 P s (Gate Post Spacing (Inside-To-Inside) for Single Gate = HC (Hinge Clearance) + W (Out-To-Out Gate Width) + LC (Latch Clearance) GATE OPENING W = LEAF WIDTH D&D DOUBLE GATE KIT # KITS & POST INTERSPACES FOR MONTAGE ATF DOUBLE SWING WELDED STEEL GATES HC LC P s 1 1 3/4 3/4 75-1/4 92-1/4 127-1/4 144-1/4 161-3/4 195-1/4 P d (Gate Post Spacing (Inside-To-Inside) for Double Gate = 2 x HC (Hinge Clearance) + 2 x W (Out-To-Out Gate Width) + LC (Latch Clearance) Page 2-13

SINGLE SWING GATES 2-Rail (Single) (4 Air Gap) CLASSIC MAJESTIC GENESIS WARRIOR CRESCENT All Single Swing Gates include hardware with the exception of and openings. * NOT AVAILABLE FOR & OPENINGS () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT * 234-42M 19 234-48M 22 * 234-60M 27 234-72M 30 234-84 31 234-96 36 * 2-42M 21 2-48M 24 H * 2-60M 31 2-72M 34 2-84 35 2-96 41 * 246-42M 26 246-48M 27 CLS, MAJ, GEN/BLK H * 246-60M 34 CLS, MAJ, GEN/BLK 246-72M 37 CLS, 246-84 39 246-96 46 * 258-42M 31 258-48M 32 CLS, MAJ, GEN/BLK H * 258-60M 38 CLS, 258-72M 44 258-84 46 258-96 55 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = WARRIOR = CRESCENT = GEMINI = * = COLOR SELECTION C M N = BRONZE G W L ( & OPENINGS NOT AVAILABLE) IN 4 AIR GAP GATE OPENING QUANTITY 7 9 13 15 17 (18 IN CRESCENT) 21 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-14

DOUBLE SWING GATES 2-Rail (Double) (4 Air Gap) CLASSIC MAJESTIC GENESIS WARRIOR CRESCENT MONTAGE All Double Swing Gates include two (2) Gate Leafs. All Double Swing Gates include hardware with the exception of 1 and 1 openings. * NOT AVAILABLE FOR & OPENINGS () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT * * 234-84MD 234-96MD 234-120MD 234-144MD 46 56 62 1 1 * 234-168D 234-192D 2-84MD 68 72 44 See Hardware Section H * 2-96MD 2-120MD 2-144MD 50 64 70 1 1 * 2-168D 2-192D 246-84MD 76 82 52 See Hardware Section H * 246-96MD 246-120MD 246-144MD 56 66 76 CLS, MAJ, GEN/BLK CLS, MAJ, GEN/BLK CLS, 1 1 * 246-168D 246-192D 258-84MD 84 92 62 See Hardware Section H * 258-96MD 258-120MD 258-144MD 66 78 90 CLS, MAJ, GEN/BLK CLS, 1 1 258-168D 258-192D 98 110 See Hardware Section STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = WARRIOR = CRESCENT = GEMINI = * = COLOR SELECTION C M N = BRONZE G W L ( & OPENINGS NOT AVAILABLE) IN 4 AIR GAP GATE OPENING 1 1 QUANTITY 7 9 13 15 17 (18 IN CRESCENT) 21 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-15

SINGLE SWING GATES MAJESTIC 2-Rail (Single) (3 Air Gap) GEMINI All Single Swing Gates include hardware with the exception of and openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 234-42M 19 234-48M 23 234-60M 29 234-72M 34 234-84 39 234-96 42 2-42M 23 2-48M 26 H 2-60M 33 2-72M 38 2-84 41 2-96 45 246-42M 27 246-48M 30 H 246-60M 36 246-72M 42 246-84 44 246-96 52 STYLE SELECTION = * = COLOR SELECTION MAJESTIC = M GATE OPENING QUANTITY GEMINI = H N = BRONZE 9 (10 IN GEMINI) CLASSIC = IN 3 AIR GAP 11 (12 IN GEMINI) GENESIS = IN 3 AIR GAP 16 19 (18 IN GEMINI) WARRIOR = IN 3 AIR GAP 21 (22 IN GEMINI) CRESCENT = IN 3 AIR GAP 26 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-16

DOUBLE SWING GATES 2-Rail (Double) (3 Air Gap) MONTAGE MAJESTIC GEMINI All Double Swing Gates include two (2) Gate Leafs. All Double Swing Gates include hardware with the exception of 1 and 1 openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 234-84MD 44 234-96MD 48 234-120MD 60 234-144MD 70 1 234-168D 68 1 234-192D 80 2-84MD 48 H 2-96MD 54 2-120MD 68 2-144MD 78 1 2-168D 78 1 2-192D 90 246-84MD 56 H 246-96MD 62 246-120MD 74 246-144MD 86 1 246-168D 88 1 246-192D 104 STYLE SELECTION = * = COLOR SELECTION MAJESTIC = M GATE OPENING QUANTITY GEMINI = H N = BRONZE 9 (10 IN GEMINI) CLASSIC = IN 3 AIR GAP 11 (12 IN GEMINI) GENESIS = IN 3 AIR GAP 16 WARRIOR = IN 3 AIR GAP 19 (18 IN GEMINI) 21 (22 IN GEMINI) CRESCENT = IN 3 AIR GAP 26 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-17

SINGLE SWING GATES 2-Rail (Single Flush Bottom) (4 Air Gap) CLASSIC MAJESTIC GENESIS WARRIOR CRESCENT All Single Swing Gates include hardware with the exception of and openings. * NOT AVAILABLE FOR & OPENINGS () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT * 234F-42M 19 234F-48M 22 * 234F-60M 27 234F-72M 30 234F-84 31 234F-96 36 * 2F-42M 22 2F-48M 24 H * 2F-60M 31 2F-72M 34 2F-84 35 2F-96 41 * 246F-42M 25 246F-48M 27 H * 246F-60M 34 246F-72M 37 246F-84 39 246F-96 46 * W M 246F-42P 25 DSKP H W M 246F-48P 27 DSKP (MAJESTIC * W M 246F-60P 34 DSKP POOL ONLY) W M 246F-72P 37 DSKP W M 246F-84 39 W M 246F-96 46 * 258F-42M 31 258F-48M 32 H * 258F-60M 38 258F-72M 44 258F-84 46 258F-96 55 STYLE SELECTION = * = COLOR SELECTION CLASSIC = C GATE OPENING QUANTITY MAJESTIC = M N = BRONZE 7 9 GENESIS = G 13 WARRIOR = W 15 CRESCENT = L ( & OPENINGS NOT AVAILABLE) 17 (CRESCENT) GEMINI = IN 4 AIR GAP 21 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-18

DOUBLE SWING GATES 2-Rail (Double Flush Bottom) (4 Air Gap) CLASSIC MAJESTIC GENESIS WARRIOR CRESCENT MONTAGE All Double Swing Gates include two (2) Gate Leafs. All Double Swing Gates include hardware with the exception of 1 and 1 openings. * NOT AVAILABLE FOR & OPENINGS () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT * 234F-84MD 234F-96MD 46 * 234F-120MD 56 234F-144MD 62 1 234F-168D 68 1 234F-192D 72 * 2F-84MD 44 2F-96MD 50 H * 2F-120MD 64 2F-144MD 70 1 2F-168D 76 1 2F-192D 82 * 246F-84MD 52 246F-96MD 56 H * 246F-120MD 66 246F-144MD 76 1 246F-168D 84 1 246F-192D 92 * 258F-84MD 62 258F-96MD 66 H * 258F-120MD 78 258F-144MD 90 1 258F-168D 98 1 258F-192D 110 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = WARRIOR = CRESCENT = GEMINI = * = COLOR SELECTION C M N = BRONZE G W L ( & OPENINGS NOT AVAILABLE) IN 4 AIR GAP GATE OPENING QUANTITY 7 9 13 15 17 (CRESCENT) 21 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-19

SINGLE SWING GATES 2-Rail (Single Flush Bottom) (3 Air Gap) MAJESTIC GEMINI All Single Swing Gates include hardware with the exception of and openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 234F-42M 19 234F-48M 23 234F-60M 29 234F-72M 34 234F-84 39 234F-96 42 2F-42M 23 2F-48M 26 H 2F-60M 33 2F-72M 38 2F-84 41 2F-96 45 246F-42M 28 246F-48M 31 H 246F-60M 37 246F-72M 43 246F-84 44 246F-96 52 R M 246F-42P 28 DSKP H R M 246F-48P 31 DSKP (MAJESTIC R M 246F-60P 37 DSKP POOL ONLY) R M 246F-72P 43 DSKP R M 246F-84 44 R M 246F-96 52 258F-42M 33 258F-48M 36 258F-60M 43 H 258F-72M 51 258F-84 55 258F-96 65 STYLE SELECTION = * = COLOR SELECTION MAJESTIC = M GATE OPENING QUANTITY GEMINI = H N = BRONZE 9 (10 IN GEMINI) CLASSIC = IN 3 AIR GAP 11 (12 IN GEMINI) GENESIS = IN 3 AIR GAP 16 19 (18 IN GEMINI) WARRIOR = IN 3 AIR GAP 21 (22 IN GEMINI) CRESCENT = IN 3 AIR GAP 26 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-20

DOUBLE SWING GATES MAJESTIC 2-Rail (Double Flush Bottom) (3 Air Gap) GEMINI MONTAGE All Double Swing Gates include two (2) Gate Leafs. All Double Swing Gates include hardware with the exception of 1 and 1 openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 234F-84MD 44 234F-96MD 48 234F-120MD 60 234F-144MD 70 1 234F-168D 68 1 234F-192D 80 2F-84MD 48 2F-96MD 54 H 2F-120MD 68 2F-144MD 78 1 2F-168D 78 1 2F-192D 90 246F-84MD 56 246F-96MD 62 H 246F-120MD 74 246F-144MD 86 1 246F-168D 88 1 246F-192D 104 258F-84MD 68 258F-96MD 74 H 258F-144MD 88 258F-72MD 104 1 258F-168D 106 1 258F-192D 126 STYLE SELECTION = MAJESTIC = GEMINI = CLASSIC = GENESIS = WARRIOR = CRESCENT = * = COLOR SELECTION M H N = BRONZE IN 3 AIR GAP IN 3 AIR GAP IN 3 AIR GAP IN 3 AIR GAP GATE OPENING QUANTITY 9 (10 IN GEMINI) 11 (12 IN GEMINI) 16 19 (18 IN GEMINI) 21 (22 IN GEMINI) 26 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-21

SINGLE SWING GATES 3-Rail (Single) (4 Air Gap) CLASSIC MAJESTIC GENESIS WARRIOR * NOT AVAILABLE FOR & OPENINGS CRESCENT All Single Swing Gates include hardware with the exception of and openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT * 334-42M 21 334-48M 24 * 334-60M 31 334-72M 34 334-84 36 334-96 42 * 3-42M 23 3-48M 27 H * 3-60M 34 3-72M 38 3-84 39 3-96 47 * 346-42M 28 346-48M 30 CLS, MAJ, GEN/BLK H * 346-60M 38 CLS, MAJ, GEN/BLK 346-72M 42 CLS, 346-84 44 346-96 52 * 358-42M 32 358-48M 35 CLS, MAJ, GEN/BLK H * 358-60M 44 CLS, MAJ, GEN/BLK 358-72M 49 CLS/BLK 358-84 51 358-96 61 * 370-42M 37 370-48M CLS, MAJ, GEN/BLK H * 370-60M 50 CLS, 370-72M 56 CLS, 370-84 59 370-96 70 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = WARRIOR = CRESCENT = GEMINI = * C M G W L = COLOR SELECTION N = BRONZE ( & OPENINGS NOT AVAILABLE) IN 4 AIR GAP GATE OPENING QUANTITY 7 9 13 15 17 (18 IN CRESCENT) 21 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-22

DOUBLE SWING GATES 3-Rail (Double) (4 Air Gap) CLASSIC MAJESTIC GENESIS WARRIOR * NOT AVAILABLE FOR & OPENINGS CRESCENT MONTAGE All Double Swing Gates include two (2) Gate Leafs. All Double Swing Gates include hardware with the exception of 1 and 1 openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT * 334-84MD 44 334-96MD 50 * 334-120MD 64 334-144MD 70 1 334-168D 72 See Hardware Section 1 334-192D 84 * 3-84MD 48 3-96MD 56 H * 3-120MD 66 3-144MD 78 1 3-168D 80 See Hardware Section 1 3-192D 94 * 346-84MD 56 346-96MD 62 CLS, MAJ, GEN/BLK H * 346-120MD 70 CLS, MAJ, GEN/BLK 346-144MD 86 CLS, 1 346-168D 88 See Hardware Section 1 346-192D 104 * 358-84MD 66 358-96MD 72 CLS, MAJ, GEN/BLK H * 358-120MD 82 CLS, MAJ, GEN/BLK 358-144MD 100 CLS/BLK 1 358-168D 102 See Hardware Section 1 358-192D 122 * 370-84MD 76 370-96MD 82 CLS, MAJ, GEN/BLK H * 370-120MD 94 CLS, 370-144MD 114 CLS, 1 370-168D 118 See Hardware Section 1 370-192D 1 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = WARRIOR = CRESCENT = GEMINI = * C M G W L = COLOR SELECTION N = BRONZE ( & OPENINGS NOT AVAILABLE) IN 4 AIR GAP GATE OPENING QUANTITY 7 9 13 15 17 (18 IN CRESCENT) 21 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-23

SINGLE SWING GATES CLASSIC MAJESTIC 3-Rail (Single) (3 Air Gap) GENESIS GEMINI All Single Swing Gates include hardware with the exception of and openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 334-42M 334-48M 334-60M 334-72M 23 26 33 38 334-84 334-96 39 46 H 3-42M 3-48M 3-60M 3-72M 25 29 36 42 3-84 3-96 44 51 H 346-42M 346-48M 346-60M 346-72M 30 33 39 47 CLS, 346-84 346-96 49 58 H 358-42M 358-48M 358-60M 358-72M 35 39 46 55 358-84 358-96 58 69 See Hardware Section H 370-42M 370-48M 370-60M 370-72M 45 53 63 370-84 370-96 67 79 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = GEMINI = WARRIOR = CRESCENT = * C M G H = COLOR SELECTION N = BRONZE IN 3 AIR GAP IN 3 AIR GAP GATE OPENING QUANTITY 9 (10 IN GEMINI) 11 (12 IN GEMINI) 16 19 (18 IN GEMINI) 21 (22 IN GEMINI) 26 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-24

DOUBLE SWING GATES CLASSIC MAJESTIC 3-Rail (Double) (3 Air Gap) GENESIS GEMINI MONTAGE All Double Swing Gates include two (2) Gate Leafs. All Double Swing Gates include hardware with the exception of 1 and 1 openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 334-84MD 48 334-96MD 54 334-120MD 68 334-144MD 78 1 334-168D 80 1 334-192D 92 3-84MD 52 3-96MD 60 H 3-120MD 74 3-144MD 86 1 3-168D 88 1 3-192D 102 346-84MD 62 346-96MD 68 CLS, H 346-120MD 80 346-144MD 96 1 346-168D 98 1 346-192D 116 358-84MD 72 358-96MD 80 H 358-120MD 94 358-144MD 112 1 358-168D 116 1 358-192D 138 370-84MD 82 370-96MD 92 H 370-120MD 108 370-144MD 130 1 370-168D 134 1 370-192D 158 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = GEMINI = WARRIOR = CRESCENT = * C M G H = COLOR SELECTION N = BRONZE IN 3 AIR GAP IN 3 AIR GAP GATE OPENING QUANTITY 9 (10 IN GEMINI) 11 (12 IN GEMINI) 16 19 (18 IN GEMINI) 21 (22 IN GEMINI) 26 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-25

SINGLE SWING GATES 3-Rail (Single Flush Bottom) * NOT AVAILABLE (4 Air Gap) FOR & OPENINGS CLASSIC MAJESTIC GENESIS WARRIOR CRESCENT All Single Swing Gates include hardware with the exception of and openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 334F-42M 334F-48M 334F-60M 334F-72M H H *4-1/2 H (MAJESTIC POOL ONLY) H H STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = WARRIOR = CRESCENT = GEMINI = 334F-84 334F-96 3F-42M 3F-48M 3F-60M 3F-72M 3F-84 3F-96 346F-42M 346F-48M 346F-60M 346F-72M 346F-84 346F-96 W M 354F-42P W M 354F-48P W M 354F-60P W M 354F-72P W M 354F-84 W M 354F-96 358F-42M 358F-48M 358F-60M 358F-72M 358F-84 358F-96 370F-42M 370F-48M 370F-60M 370F-72M 370F-84 370F-96 * C M G W 22 24 31 34 36 42 24 27 34 38 39 47 27 30 38 42 44 52 31 34 42 47 48 57 32 35 44 49 51 61 37 50 56 59 70 = COLOR SELECTION N = BRONZE L ( & OPENINGS NOT AVAILABLE) IN 4 AIR GAP DSKP DSKP DSKP DSKP GATE OPENING CLS, QUANTITY 7 9 13 15 17 (18 IN CRESCENT) 21 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-26

DOUBLE SWING GATES 3-Rail (Double Flush Bottom) * NOT AVAILABLE (4 Air Gap) FOR & OPENINGS CLASSIC MAJESTIC GENESIS WARRIOR CRESCENT MONTAGE All Double Swing Gates include two (2) Gate Leafs. All Double Swing Gates include hardware with the exception of 1 and 1 openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 334F-84MD 334F-96MD 44 50 334F-120MD 64 334F-144MD 70 1 1 334F-168D 334F-192D 72 84 3F-84MD 3F-96MD 48 56 H 3F-120MD 66 3F-144MD 78 1 1 3F-168D 3F-192D 78 94 346F-84 MD 346F-96MD 56 62 H 346F-120MD 70 346F-144MD 86 1 1 346F-168D 346F-192D 88 104 W M 354F-84MD 62 W M 354F-96MD 68 *4-1/2 H W M 354F-120MD 76 (MAJESTIC W M 354F-144MD 94 ONLY) 1 W M 354F-168D 96 1 W M 354F-192D 114 358F-84MD 358F-96MD 66 72 CLS, H 358F-120MD 358F-144MD 82 100 1 1 358F-192D 358F-168D 122 102 370F-84MD 76 370F-96MD 82 370F-120MD 94 H 370F-144MD 114 1 370F-168D 118 1 370F-192D 1 STYLE SELECTION = * = COLOR SELECTION CLASSIC = C GATE OPENING QUANTITY MAJESTIC = M N = BRONZE 7 GENESIS = G 9 WARRIOR = W 13 15 CRESCENT = L ( & OPENINGS NOT AVAILABLE) GEMINI = IN 4 AIR GAP 17 (18 IN CRESCENT) 21 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-27

SINGLE SWING GATES CLASSIC MAJESTIC 3-Rail (Single Flush Bottom) (3 Air Gap) GENESIS GEMINI All Single Swing Gates include hardware with the exception of and openings. () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT H H *4-1/2 H (MAJESTIC ONLY) H H STYLE SELECTION = CLASSIS = MAJESTIC = GENESIS = GEMINI = WARRIOR = CRESCENT = 334F-42M 334F-48M 334F-60M 334F-72M 334F-84 334F-96 3F-42M 3F-48M 3F-60M 3F-72M 3F-84 3F-96 346F-42M 346F-48M 346F-60M 346F-72M 346F-84 346F-96 R M 354F-42P R M 354F-48P R M 354F-60P R M 354F-72P R M 354F-84 R M 354F-96 358F-42M 358F-48M 358F-60M 358F-72M 358F-84 358F-96 370F-42M 370F-48M 370F-60M 370F-72M 370F-84 370F-96 * C M G H = COLOR SELECTION N = BRONZE IN 3 AIR GAP IN 3 AIR GAP 23 26 33 38 39 46 25 29 36 42 44 51 30 33 39 47 49 58 34 37 44 54 54 64 35 39 46 55 58 69 45 53 63 67 79 DSKP DSKP DSKP DSKP GATE OPENING QUANTITY 9 (10 IN GEMINI) 11 (12 IN GEMINI) 16 19 (18 IN GEMINI) 21 (22 IN GEMINI) 26 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-28

DOUBLE SWING GATES CLASSIC 3-Rail (Double Flush Bottom) (3 Air Gap) MAJESTIC GENESIS GEMINI MONTAGE All Double Swing Gates include two (2) Gate Leafs. All Double Swing Gates include hardware with the exception of 1 and 1 openings. () () (ACTUAL) ITEM NUMBER GATE GATE HEIGHT GATE OPENING GATE LEAF WIDTH WEIGHT SUPPLIED HDW KIT NO YES PART # H H *4-1/2 H (MAJESTIC ONLY) H H 1 1 1 1 1 1 1 1 1 1 1 1 STYLE SELECTION = CLASSIS = MAJESTIC = GENESIS = GEMINI = WARRIOR = CRESCENT = 334F-84MD 334F-96MD 334F-120MD 334F-144MD 334F-168D 334F-192D 3F-84MD 3F-96MD 3F-120MD 3F-144MD 3F-168D 3F-192D 346F-84MD 346F-96MD 346F-120MD 346F-144MD 346F-168D 346F-192D R M 354F-84MD R M 354F-96MD R M 354F-120MD R M 354F-144MD R M 354F-168D R M 354F-192D 358F-84MD 358F-96MD 358F-120MD 358F-144MD 358F-168D 358F-192D 370F-84MD 370F-96MD 370F-120MD 370F-144MD 370F-168D 370F-192D * C M G H = COLOR SELECTION N = BRONZE IN 3 AIR GAP IN 3 AIR GAP 48 54 68 78 80 92 52 60 74 86 88 102 62 68 80 96 98 116 68 74 88 108 110 128 72 80 94 112 116 138 82 92 108 130 134 158 GATE OPENING QUANTITY 9 (10 IN GEMINI) 11 (12 IN GEMINI) 16 19 (18 IN GEMINI) 21 (22 IN GEMINI) 26 For gate leaves more than 6 feet in width, gusset straps are welded in all four corners, an intermediate upright is added in the center of the leaf and truss cables are provided for added strength. Note: Custom gate leaf widths are available upon request, but would incur a 10% engineering charge based on the nearest larger standard gate leaf width. Page 2-29

ARCHED SINGLE SWING GATES 2-Rail (Single Arched) (4 Air Gap) CLASSIC MAJESTIC GENESIS All Single Swing Gates include hardware () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT * 234-42AM 234-48AM 234-60AM 234-72AM 20 24 29 33 H * 2-42AM 2-48AM 2-60AM 2-72AM 22 26 33 38 H * 246-42AM 246-48AM 246-60AM 246-72AM 26 29 36 39 H * 258-42AM 258-48AM 258-60AM 258-72AM 41 34 46 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = * C M G = COLOR SELECTION N = BRONZE GATE OPENING QUANTITY 7 9 13 15 All gates are supplied with 2 ea. TruClose Mini-Multi Adjust Hinge (TCAMA1) and 1 ea. LokkLatch (LLAAB) Page 2-30

ARCHED SINGLE SWING GATES 2-Rail (Single Flush Bottom) (4 Air Gap) MONTAGE CLASSIC MAJESTIC GENESIS All Single Swing Gates include hardware () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT H H H (MAJESTIC POOL ONLY) H * W M W M W M W M 234F-42AM 234F-48AM 234F-60AM 234F-72AM 2F-42AM 2F-48AM 2F-60AM 2F-72AM 246F-42AM 246F-48AM 246F-60AM 246F-72AM 246F-42AP 246F-48AP 246F-60AP 246F-72AP 258F-42AM 258F-48AM 258F-60AM 258F-72AM 20 25 29 33 31 26 33 37 26 29 36 39 26 29 36 39 41 34 46 DSKP DSKP DSKP DSKP STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = * C M G = COLOR SELECTION GATE OPENING N = BRONZE QUANTITY 7 9 13 15 All gates except for pool gates are supplied with 2 ea. TruClose Mini-Multi Adjust Hinge (TCAMA1) and 1 ea. LokkLatch (LLAAB). Pool gates are supplied with 2 ea. TruClose Mini-Multi Adjust Hinge (TCAMA1) and 1 ea. MagnaLatch Top Pull (MLTPS-2PGA). Page 2-31

ARCHED SINGLE SWING GATES 3-Rail (Single Arched) (4 Air Gap) CLASSIC MAJESTIC GENESIS All Single Swing Gates include hardware () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 334-42AM 334-48AM 334-60AM 334-72AM 22 26 33 37 H 3-42AM 3-48AM 3-60AM 3-72AM 24 29 36 41 H 346-42AM 346-48AM 346-60AM 346-72AM 28 32 45 H 358-42AM 358-48AM 358-60AM 358-72AM 33 37 46 52 H 370-42AM 370-48AM 370-60AM 370-72AM 38 42 52 59 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = * C M G = COLOR SELECTION N = BRONZE GATE OPENING QUANTITY 7 9 13 15 All gates are supplied with 2 ea. TruClose Mini-Multi Adjust Hinge (TCAMA1) and 1 ea. LokkLatch (LLAAB) Page 2-32

ARCHED SINGLE SWING GATES 3-Rail (Single Flush Bottom) (4 Air Gap) CLASSIC MAJESTIC GENESIS MONTAGE All Single Swing Gates include hardware () () (ACTUAL) ITEM NUMBER GATE SUPPLIED HDW KIT 334F-42 AM 334F-48AM 23 26 334F-60AM 33 334F-72AM 37 H 3F-42AM 3F-48AM 3F-60AM 3F-72AM 23 29 36 41 H 346F-42AM 346F-48AM 346F-60AM 346F-72AM 28 32 45 *4-1/2 H (MAJESTIC POOL ONLY) W M W M W M W M 354F-42AP 354F-48AP 354F-60AP 354F-72AP 24 36 44 50 DSKP DSKP DSKP DSKP H 358F-42 AM 358F-48AM 358F-60AM 358F-72AM 33 37 46 52 H 370F-42AM 370F-48AM 370F-60AM 370F-72AM 38 42 52 59 STYLE SELECTION = CLASSIC = MAJESTIC = GENESIS = * C M G = COLOR SELECTION N = BRONZE GATE OPENING QUANTITY 7 9 13 15 All gates except for pool gates are supplied with 2 ea. TruClose Mini-Multi Adjust Hinge (TCAMA1) and 1 ea. LokkLatch (LLAAB). Pool gates are supplied with 2 ea. TruClose Mini-Multi Adjust Hinge (TCAMA1) and 1 ea. MagnaLatch Top Pull (MLTPS-2PGA). Page 2-33