DROP CEILING SAMPLE LAYOUT FOR FIXTURES WEIGHTING UP TO 400 LBS

Similar documents
Enclosed Cable System with Portable Lowering Tool for Drop Ceiling Mount * Manual System for Indoor and Outdoor Use.

Design PTS6-XX SERIES

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

ALL700RM-230V INSTALLATION INSTRUCTIONS

Worm Gear Hand Winches Up to 4000 lb capacity

ALL W INSTALLATION INSTRUCTIONS

Please make your selections below to view, search or print ACCO Material Handling Solutions WRIGHT SPEEDWAY and WRIGHT WORK-RATED product pages.

StopGate TM Barrier Arm GENERAL SPECIFICATIONS

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

SERIES 12 SUB-FHP RIGHT ANGLE DC GEARMOTORS

POWER WINCHES 4HPF SERIES

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

STRAIGHT BLADE PLUGS & CONNECTORS

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Installation Instructions Table of Contents

Amphenol 97 Series MIL-DTL-5015

SECTION SIX. Reels. Introduction

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Safety Lampholders and Pendants

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Installation Instruction

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

SERIES G603 STANDARD FRONT MOUNT GAGE

QUICK REFERENCE Stock Sub-FHP Gearmotors

INSTALLATION INSTRUCTIONS AMBASSADOR DRUM OVERHEAD SERIES 100 DUMBWAITER

THE ENCLOSURE HARDWARE SUPPLIER

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

TRUMBULL MUD VALVES. Installation, Operation and Maintenance Manual

FIXED PITCH PROPELLER FANS

forward curved inline duct blowers

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

General Information 351 Series Powerglide

Climas y Proyectos Leyco, S.A. de C.V.

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Instructions & Operation Manual TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE.

A Zy-Tech Global Industries Product

MUELLER ECCENTRIC PLUG VALVE

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

Diameter Strength 1st layer mid drum full drum 1st layer mid drum full drum. in. mm (lb.) (kg.) ft. m ft. m ft. m ft. m ft. m ft.

Contents Project: Model: Chk d: Date:

Slide-Rite & Slide-Rite CR Gearbox

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

QUICK REFERENCE Stock Sub-FHP Gearmotors

A. This Section includes the following types of sectional overhead doors:

TNC Series Series C TN 114

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Cable pulling technology

Index. Butterfly Valves

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

SECTIONAL WARPING MACHINE SERVOMECH-100

600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS

Swing-Flex Check Valve

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

SURFACE TRACK (120/250V) SPECIFICATIONS

DC-RU DIVIDER CURTAIN ROLL-UP

Distributed by Tri-State Equipment Company Inc

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

VANEAXIAL & TUBEAXIAL FANS

AMERICAN FLOW CONTROL 4 3/4 WATEROUS TREND FIRE HYDRANT

MIL-DTL Series 1 Solder Type PT

DTP Series : Contacts (Open Barrel) Type Barrel Type GA Size

Distributed by Tri-State Equipment Company Inc

About Our Blocks. Section 2. Tip!

L Listed FEATURES. Series Lamps Wattage # of Lamps ICR= remote fixture 7= 7.2 watts. L Listed. Phantom TM FEATURES

Glossary. Cable Clamps A manufactured device used to secure two pieces of cable to each other. Size of clamp is determined by the cable diameter.

Catalog # Project. Comments. Prepared by. 11" [279mm] 8-3/4" [222mm] ESCUTCHEON PLATES. 2-5/8" [67mm] 3/4" [19mm] Dia. Hole. 3" [77mm] 1-1/2" [39mm]

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

boom extension (23 lb) wire rope. Crane breaks down for transport

Tube Axial Inline Fans

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

Series 577. Vertical Flow Softwall Portable Cleanroom. Series 577 Vertical Flow Softwall Portable Cleanroom

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Industry best 5 year fan housing warranty, 1 year motor warranty

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

Applications. Standard Materials

Electric Actuators Maximum in-lbs

Juno Trac-Lites System A complete and customizable track system with an array of features

DT04 08P + W8P

American Flow control 5 1/4 b-84-b-5

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

DETAIL SPECIFICATION SHEET

Electric Actuators Maximum in-lbs

R.C. PLATH CO. Specialty Marine Hardware 2010 PLATH

MODULAR. ACTUATORS 100 to 2,000 lbs 444 to 8,896 N

SQUARE INLINE CENTRIFUGAL FANS

EZ Tool Articulating Arm

Powerful + Efficient + Reliable

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

Vision 17B/BT. Section II Parts and Service Manual (78454B) CLARKE TECHNOLOGY Operator's Manual - Vision 17B/BT Page -23-

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

INSTRUCTION SHEET PRL-97X04 AC AND DC VOLTAGES

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Transcription:

MLS-400-THX-70-4C MOTORIZED SYSTEM FIXTURE LOWERING DEVICE DROP CEILING SAMPLE LAYOUT FOR FIXTURES WEIGHTING UP TO 400 LBS MOTOR SHOULD BE MOUNTED IN A LOCATION WITH EASY ACCESS. MOTOR SHOULD BE MOUNTED IN ANY ORIENTATION TO A RIGID STRUCTURAL SUPPORT CABLE PATH AND PULLEY SHOULD BE ALIGNED WITH THE CENTERLINE OF THE CABLE DRUM AND FREE FROM OBSTRUCTIONS DISCONNECT UNIT SUPPORT MUST BE LEVELLED AND STRONG ENOUGH TO SUPPORT 5 TIMES FIXTURE WEIGHT, IN ALL DIRECTIONS MOTOR 7 TO 30 HORIZONTAL RUN ELECTRICAL DISCONNECT UNIT SCU-2A-MS-4C DROP CEILING CHAIN LINK (REQUIRED) BRASS CANOPY OPTION CAN-8-65 WALL STUD LIGHT FIXTURE BY OTHERS (MUST BE LEVELLED) CP-2 CONTROL PANEL IN VISIBLE SIGHT OF FIXTURE BEING LOWERED BEEPER RAISE LOCK AUTO LOWER EMERGENCY STOP GRADE CP-2 CONTROL PANEL 835 Industrial Dr Elmhurst, IL 60126 Ph: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 1 MLS-PG01-400-THX Layout-081814

MLS-400-THX-YY-4C BILL OF MATERIAL MOTORIZED LOWERING SYSTEMS FOR FIXTURE WEIGHT OF UP TO 400 LBS MLS-400-TH5-70-4C (5 WIDE DRUM, NEAREST PULLEY/SCU-2A, 7-30FT AWAY) MLS-400-TH8-70-4C (8 WIDE DRUM, NEAREST PULLEY/SCU-2A, 12-30FT AWAY) QTY PART NUMBER DESCRIPTION 1 SCU-2A-MS-4C ELECTRICAL DISCONNECT UNIT WITH LOCKING MECHANISM 1 CP-2 CONTROL PANEL WITH BEEPER ASSEMBLY 1 3/16 DIA LOWERING CABLE CABLE ASSEMBLY (CABLE LENGTH: AS REQUIRED, 70FT STD.) MOTOR ASSEMBLY OPTION 1 TH5 5 WIDE DRUM MOTOR ASSEMBLY (MLS-400-TH5-70-10C) 1 TH8 8 WIDE DRUM MOTOR ASSEMBLY (MLS-400-TH8-70-10C) OPTIONS SUFFIX DESCRIPTION -YY ADDITIONAL CABLE LENGTH, STANDARD 70 FEET X= NUMBER OF CONTACTS (UP TO 8) -XC STANDARD 4 CTS FOR 2 CIRCUITS PLUS 1 EARTH -CL CHAIN LINKS REQUIRED IF NOT PART OF FIXTURE -CR CORROSION RESISTANT (contact factory for details) -38 WITH 3/8 CONDUIT INTERNAL THREAD STEM OPTIONAL MATERIAL AS NEEDED CAN-8-65 BRASS CANOPY CP-8 CONTROL PANEL FOR UP TO 8 SYSTEMS 3P-5 PULLEY 3P-6 PULLEY 3P-7 PULLEY All fixtures MUST be hung by at least 4 Chain links or Quick links. Links must be rated for the size and weight of the fixture. They can be purchased thru Lighting & Lowering Systems. COMMENTS The disconnect unit must be mounted to a HORIZONTAL RIGID STRUCTURE. All mounting must be able to withstand static and dynamic loading for at least 5 X weight of the fixture in all directions. This structure must be approved by others. The winch or motor assembly must be placed away from the first pulley or disconnect unit: 7-30ft for TH5, 12-30ft for TH8 motors. A pulley must be used every 2-30' of horizontal straight run. Centerline of pulley grove must be aligned with cable path. Cable path must be free from interference. Please visit our website at www.lowering-device.com for specification-sheets if not provided with the quote. If the system is mounted under certain climatic conditions, please inform us. Please provide any other specifications, conditions or special requirements at this time. Specifications are subject to change without notice. 835 Industrial Dr Elmhurst, IL 60126 Ph: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 2 MLS-PG02-400-THX-Bill of Material-081814

MOTORIZED LOWERING SYSTEMS Specs for TH5 & TH8 Motor Assemblies Specs for TH5 (4WP2) and TH8 (4WP2T8) Worm Gear Power Winch Assemblies Up to 1100 LB Fixture weight Capacity 115 Bolt Single Phase Electric Motor includes power cord with grounded plug. Machine Cut Worm Gears provide accurate operation and long lasting service. Enclosed Oil Bath provides continuous lubrication of gears to minimize wear. Oil seals keep oil in and dirt out. Internal Mechanical Brake provides positive load control for lifting and lowering operations. Ball Bearings and self-aligning bronze bearings provide smooth and efficient operation. Pressure Plate applies pressure to drum and wire rope to help maintain uniform winding. Mounting Options include floor, wall, or ceiling. Two-year Limited Warranty Cast Aluminum construction, for lightweight strength. Corrosion Resistant durable paint finish protects against corrosion in harsh environments. Large Diameter Drums minimize wear to the wire rope and help extend its life. Relay Box includes two heavy duty, 1,000,000 cycle, enclosed (dust-proof) Relay. Also includes Adjustable Current Sensor. Junction Box with color coded wire leads for ease of installation and trouble shoot. Part Number Motor HP Load rating (lb) Wire Line speed (fpm) 1 st Mid Full Rope 1 st Full Layer drum drum dia. (in) layer drum Drum capacity (ft) 1 st layer Mid dru m Full drum approx Ship wt. (lb) TH5 1.3 2000 1500 1200 1/4 8 13 11 35 70 85 TH8 1.3 2000 1200 800 1/4 8 19 19 110 220 101 Motor Assemblies Drum Dimensions Part Number Drum diameter Flange diameter Drum width Fleet angle distance TH5 2.50 in 5.00 in 5.00 in 7 ft TH8 2.50 in 7.00 in 8.00 in 12 ft Dimensions are for reference only and subject to change notice. Fleet angle distance is the recommended distance between cable drum and lead sheave or disconnect unit. Specifications are subject to change without notice. 835 Industrial Dr Elmhurst, IL 60126 Ph: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 3 MLS-PG03-THX-Motor specs-081814

MOTORIZED LOWERING SYSTEMS Dimensions for TH5 and TH8 Assemblies IMPORTANT: Study all applicable codes, manuals, and regulations. Be sure to read the Installation and Operations Guide before installing and operating. TH5 (4WP2) TH8 (4WP2T8) Dimensions for the TH5 and TH8 assemblies (in) Model A B C D E F H J K M N P R S m (hole dia.) TH5 15.63 17.28 1.72 3.50 1.375 9.00 12.84 1.72 3.75 13.50 1.00 4.00 6.50.41 TH8 15.62 17.80 2.75 4.88 1.44 6.43 14.25 2.25 5.81 10.25 1.25 7.00 11.38.41 Dimensions are for reference only and subject to change without notice. Specifications are subject to change without notice. 835 Industrial Dr Elmhurst, IL 60126 PH: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 4 MLS-PG04-THX-Motor Dimen-081814

SCU-2A-XC ELECTRICAL DISCONNECT UNIT (EDU) with 4-8 Contacts Specifications Guide The EDU shall have a 3-way tracking guide and support. It shall be constructed of precision cast high strength aluminum alloy 356-T6. A permanently fixed position piece incorporating a special tracking guide system permits the moveable portion of the Disconnect Unit to align in the same position every time the system is operated, thereby eliminating the need to re-orientate the fixture. The Electrical Disconnect Unit shall have twin high strength stainless steel locking cams securing the load of the Lower Contact Assembly and fixture. All tension on the cable is relieved when the fixture is in the raised position. The MULTI-CONTACT Connector assembly shall be modular for easy installation and retrofit requirements. The connector shall also have 4-8 size 12 contacts. Material of contacts shall be copper with nickel plating, and with gold plating over nickel per MIL-G-45204. Electrical contacts shall have a rating of 20 year mean time between failures. All hardware shall be corrosion resistant stainless steel. It shall have a self-aligning and self-adjusting mechanical system comprised of two principal assemblies: The UPPER CONTACT HALF shall house the socket contacts. It shall incorporate spring assisted polymer contact body with precision-machined stainless steel guideposts. The socket contact body shall have integral guideposts for precise contact alignment. The LOWER CONTACT HALF shall house the pin contacts comprised of spring assisted polymer contact body with precision-machined stainless steel guidepost receivers. The pin contact body aligns with guideposts of integral socket body guideposts. The wire leads are potted in Superflex Black RTV Silicone, an industrial grade sealant for bonding and sealing. The unit shall have a guidepost constructed of precision cast high strength stainless steel. It shall utilize a cast-in-place guide bar for precise alignment of Lower Contact Assembly with the fixed portion of the EDU. The EDU shall have twin (2) tracking support arms made of precision cast high strength stainless steel. When locked in the 3-Way Tracking Guide and Support notches, the Twin Tracking/Support Arms shall hold the weight of the fixture and components and it shall remove all tension from the Control Cable or Lowering Cable. The lower contact assembly shall be constructed of precision cast high strength aluminum alloy. It shall feature a cast-in-place guide that mate with the fixed portion of the Disconnect Unit to aid in tracking and stability. All hardware used on the Lower Contact Assembly as well as the entire Disconnect Unit shall be made of corrosion resistant stainless steel. The disconnect unit shall have a HOUSING SEAL made up of a spun aluminum closure ring with a sealing gasket constructed of extra flexible polymer providing a weather-tight seal between Lower Contact Assembly and Disconnect Unit Cover. This provides a flexible environmental seal. Seal swipes and conforms to interior of cylinder housing during all operating stages of the disconnect unit. U.S. Patent No. 6,261,122 Electrical Contact Rating: 120V, 20 Amps per contact, (Multiple circuits) 240V/277V, 15 Amps per contact (Multiple circuits) 480V, 10 Amps (1 circuit max) 600V, 5 Amps (1 circuit max) Mechanical Rating: 400 lbs with 6:1 safety factor Weight: 8.5 LBS SYSTEM DESIGNED SPECIFICALLY FOR USE WITH LIGHT FIXTURES, CAMERAS, AND RELATED EQUIPMENT ONLY. NOT FOR LIFTING PEOPLE OR THINGS OVER PEOPLE. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 835 Industrial Drive Elmhurst, IL 60126 PH 708-681-4330 Fax 708-681-4006 www.lowering-device.com h Page 05 MLS-PG05-06-400-SCU2A specs-dimensions-081814

SCU-2A-XC ELECTRICAL DISCONNECT UNIT (EDU) with 4-8 Contacts Specifications Guide Frontal View Side View CAST ALUMINUM SUPPORT HOUSING ½ CONDUIT ELECT WIRE ENTRANCE STEEL SHEAVE WITH SINTERED BRONZE BEARING HIGH STRENGTH CAST ALUMINUM TRACKING GUIDE AND SUPPORT PRECISION CAST STAINLESS STEEL TWIN SUPPORT/LOCKING CAM ARMS HIGH STRENGTH CAST ALUMINUM MOVEABLE LOWER CONTACT ASSEMBLY ¾ EXTERNAL PIPE THREAD 4 DIA. MOUNTING FLANGE UPPER HALF SPRING LOADED SOCKET ASSEMBLY LOWER HALF SPRING LOADED PIN ASSEMBLY ALUMINUM CLOSURE COVER WITH SOLID NEOPRENE SEAL FIXTURE MOUNTING FLANGE SEAMLESS ALUMINUM ROUND COVER 12 3/8 INTERNAL PIPE THREAD 14 ¼ ¼ MOUNTING HOLES (4) 19 7/8 Measurement to bottom of pipe thread 3 ¼ Options Suffix (4) Contacts (2 circuits) -4C (6) Contacts (3 circuits) -6C (8) Contacts (4 circuits) -8C 3/8 Internal Pipe Thread Mounting -38 Other mounting-consult factory 6 ½ Measurement to bottom of quick link 835 Industrial Drive Elmhurst, IL 60126 PH 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 06 h MLS-PG05-06-400-SCU2A specs-dimensions-081814

SCU-2A-XC CABLE ORIENTATION AND MOUNTING DETAILS Cable Orientation Options: The disconnect unit allows the cable path orientation at an angle. The pulley installed in the upper casting attached to the disconnect unit guides the cable in the required orientation. Mounting Details: The disconnect unit must be mounted on rigid horizontal support. This support must be approved by others to be able to withstand static and dynamic loading of at least 5 X the weight of the fixture in all directions. Unistrut mounting structure should not be used due to bending and flexing of the unistrut during the raising and lowering operation. Square center hole is optional. Please specify if required at the time of ordering. 835 Industrial Drive Elmhurst, IL 60126 USA PH: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 07 MLS-PG07-400-Cable Orientation-081814

MOTORIZED LOWERING SYSTEM COMPONENTS For MLS Systems LOWERING CABLE SPECIFICATIONS Comp. A-Carbon Steel Zinc Coated (Standard). Comp. B-Corrosion Resistant Stainless Steel (Optional). MLS Assembly Nominal Diameter Of Wire Rope Construction Minimum Breaking Strength Comp. A Minimum Breaking Strength Comp. B Maximum Fixture Weight (lbs) Cable Weight Per 1000 Feet (lbs.) MLS-400 3/16 7x19 4,200 3,700 600 65.0 MLS-600 MLS-1100 1/4 7x19 7,000 6,000 1100 110.0 Cable is cut to size at the factory. Notify factory (or Sales Rep) of cable length before ordering. SPECIFICATIONS FOR CP-2 CONTROL PANEL RAISE LOCK LIGHTING & LOWERING SYSTEMS OFF Press When Beeper Sounding 4 ½ SQ ON EMERGENCY AUTO LOWER STOP Computerized panel. Programmable lowering distance. TEACH switch on front panel in back of wall plate allows for easy programming of Control Panel. Key lock power ON/OFF switch. Connection Box: 4 Square Double Deep (3 1/4 ) box provided. The Connection Box comes with 1/2 & 3/4 comb. knockouts. 4 ½ Square White Wall Plate Cover provided. Operating Voltage: 105V-135V AC 50/60 Hz @ 1/4 ampere. Motor current is separate. See motor specs. Buttons: Momentary switches with LED lights. Equipped with Beeper to indicate when fixture has reached the top. LOCK button (feature) assures operator that system is mechanically locked. When locked, cable is slack and power to the motor is off. * All specifications subject to change without notice 835 Industrial Dr Elmhurst, IL 60126 PH: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 8 MLS-PG08-400-CP-2 Cable-081814

MLS CP-2 CONTROL PANEL WIRING SCHEMATICS CONTROL WIRING BOX RELAY BOX (AUTHORIZED PERSONNEL ONLY) TO OUTLET OR SERVICE SWITCH (BY OTHERS). TO AVOID VOLTAGE DROP, USE MINIMUM #10 CABLE. CONNECT TO SEPARATE CIRCUIT THAN FIXTURE OR CONTROL PANEL. 120 V. 50/60 hz. POWER SUPPLY SEPARATE CIRCUIT THAN MOTOR. Factory provides color coded insulated wire leads coming out of the control panel, the disconnect unit, and the motor control wiring box. All 14 AWG wire leads are for 120 V. power. Motor and CP-2 control panel operate off of 120 Volt unless otherwise noted. To avoid voltage drop, use proper size cable in between disconnect unit, motor, and control panel. Due to the motor amp rating, Motor should be on a separate circuit than the fixture and the control panel. Electrical wire for the fixture is separate. Electrical circuit for the light fixture must be on a different circuit than for the motor. All electrical wires and conduits between the disconnect unit, motor, and the control panel, are provided by others. Contractor should maintain same color codes for ease of installation, maintenance, and continuity check. * Specifications subject to change without notice. Details shown are intended as an application example only. Actual installation details may vary. Contact manufacturer s representative or factory for specific details about special installation application or other information. 835 Industrial Dr Elmhurst, IL 60126 PH: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 9M MLS-PG09-400-CP2-Wiring Schematics-081814

MOUNTING ACCESSORIES PULLEYS RATED FOR 20-400 LBS LOAD Various types of pulleys are available and should be designed for exact load and gear box. All pulleys have oilite bronze bearings for maintenance free life. This also insures their use for dirty atmosphere applications. Painted pulleys are available for highly corrosive areas. Pulleys can be spaced 6-30 apart on horizontal runs. A pulley must be used at every 30 of horizontal straight runs. Pulleys are required when vertical or horizontal changes in direction occur. It is important that pulleys are properly aligned. The centerline of the pulley-sheave grove must coincide with the centerline of the cable path when installing. Always take pulley friction into consideration if loads are near limits of the gear box. Pulleys must be installed on rigid surfaces which are able to withstand at least 5 X load of the fixture in all directions. The installation must be approved by others. 3P-6 3P-6 Load capacity for a 3P-6 pulley is 20-400 lbs. A 3P-6 pulley can facilitate a change in direction of the cable from wall to ceiling i.e. from vertical to horizontal. 3P-6 pulleys should be spaced 6-30 apart on horizontal runs. Change in direction of cable to angles other than 90 degrees is possible. See page p3 for details. This pulley allows the twisted quick-link to pass through. 3P-7 3P-7 A 3P-7 pulley can facilitate a change in direction of the cable on the same plane i.e. on the ceiling or on the wall. The pulley allows the cable connecting link to pass through. Load capacity: Up to 400 lb. fixtures. Frame Material: Frame material of zinc plated 7gge. Steel. Frame Material Option: Stainless steel frame. Contact factory. Sheave Material: Sheave of cast aluminum with oilite bronze bearing. Mounting: Two mounting holes for 3/8 bolts. Hardware by others. Type of hardware depends on the type of structure that the pulley is mounted to. Structure must not move while the system is in operation. * Specifications subject to change without notice. 835 Industrial Dr Elmhurst, IL 60126 PH: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 10 MLS-PG10-400-Pulley Specs-081814

MOUNTING ACCESSORIES CABLE GUIDING OPTIONS 3P-6 and 4P-4 Uses 3P-7 and 4P-3 Uses 3P-6 and 4P-4 pulleys (depending upon load) can facilitate a change in direction of the cable from wall to ceiling i.e. from vertical to horizontal. These pulleys should be spaced 6-30 apart on horizontal runs. The above examples show that change in direction of cable to angles other than 90 degrees is possible. These pulleys can be placed horizontally (examples 2 and 4), vertically ( examples 1 and 3) and on inclined surfaces for maximum versatility as long as the cable path is aligned to the pulley sheave grove and as long as the cable path is not interfered by any obstacles. 3P-7 and 4P-3 pulleys (depending upon load) can facilitate a change in direction of the cable on the same plane. Example 1 is a simple way using 4 pulleys to go around an obstruction in the cable path. In example 2, the pulley allows the cable to change direction on the same plane. MAXIMUM FIXTURE LOAD 400 LBS 3P-7 1100 LBS 4P-3 MAXIMUM FIXTURE LOAD 400 LBS 3P-6 1100 LBS 4P-4 * Specifications subject to change without notice. Details shown are intended as an application example only. Actual installation details may vary. Contact manufacturer s representative or factory for specific details about special installation application or other information. Lifting capacity is 400 lbs and must not be exceeded. 835 Industrial Drive Elmhurst, IL 60126 PH: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 11 MLS-PG11-400-4P6-3P7Cable Guide-102314

MOTORIZED LOWERING SYSTEMS CAN-8-65 CANOPY ASSEMBLY Specification Sheet for CAN-8-65 CAN-8-65: Height -compensating canopy assembly CEILING C ELECTRICAL CONTACTUNIT 7-1/4" UPPERADJUSTING NUT CANOPY 3/4" LOWERADJUSTING NUT } SPRINGCHAMBER VERTICAL DISTANCE CHANDELIERMOVES DURINGLOCKINGANDUNLOCKINGSTAGES SUPPORTRING During the lowering or raising of the fixture, when the electrical contacts engage within the ceiling mounted locking device, there is approximately ¾ travel up and down to set the locking mechanism. The height compensating canopy will adjust to this condition to assure that the canopy will remain against the ceiling surface. CANOPY: One piece 8 diameter and 2¼ deep heavy gauge spinning with standard polished brass finish. SPRING CHAMBER: Telescoping cups with bright brass finish enclose a 3/8 pipe stem that connects the electrical contact unit with the chandelier support ring. A large diameter compression spring within the chamber provides a constant and even pressure to keep the canopy against ceiling. SUPPORTING RING: A heavy duty solid brass ring is provided. The ring is threaded onto the end of the 3/8 stem and secured with a lock nut. Electrical wires are fed through a center hole in the ring. Wiring from the locking contact mechanism to the chandelier support chains, connecting links, and chandeliers with related hardware are provided by others. All specifications subject to change without notice. 835 Industrial Dr Elmhurst, IL 60126 PH: 708-681-4330 Fax 708-681-4006 www.lowering-device.com Page 12 MLS-PG12-400-CAN-8-65-081814