Grundfos Direct Sensors

Similar documents
Grundfos Direct Sensors

Renewable Solar Inverter, RSI

Renewable Solar Inverter, RSI

GRUNDFOS DATA BOOKLET. Self-priming. 50/60 Hz

GRUNDFOS DATA BOOKLET. Fire CRFF. Grundfos fire systems. VdS-approved CR pumps for fire systems 50 Hz

GRUNDFOS PRODUCT GUIDE LM, LP. Single-stage close coupled in-line circulating pumps 60 Hz

Grundfos solar surface pump

Grundfos solar surface pump

GRUNDFOS PRODUCT GUIDE CH, CHN. Horizontal multistage end-suction pumps

GRUNDFOS DATA BOOKLET. Control HVAC. For variable-primary-flow systems

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

INSERTION flow sensor for continuous flow measurement

Grundfos Home Booster

GRUNDFOS DATA BOOKLET. RC pumps 50 Hz. Multistage, canned-motor, refrigerant pump

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

Pressure Transmitters

Pressure Sensor - EPT3100

Insertion magnetic inductive flowmeter

GRUNDFOS DATA BOOKLET. Fire NKF. Grundfos fire systems. Fire pump sets with electrically and diesel-powered pumps according to DBI 251/CEA4001

Lenntech GRUNDFOS DATA BOOKLET. CME 15. Horizontal, multistage centrifugal pumps 50/60 Hz

Technical Data Measuring principle Thin-film-on-steel Media temperature -40 C C

GRUNDFOS PRODUCT GUIDE. SQFlex. Renewable-energy based water-supply systems 50/60 Hz

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

INSERTION flowmeter with paddle wheel, ELEMENT design

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Positive displacement flowmeter for continuous flow measurement

Paddle-wheel flow controller with optical principle for On/Off control

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

GRUNDFOS PRODUCT GUIDE. VersaFlo. TP circulator pumps 60 Hz

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

RCM - Direct Reading Flowmeters

EPI Applications. Features

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

Submersible Pressure

ECT Applications. Features

Industrial Pressure Transmitter

Level Measurement Point level measurement - RF Capacitance switches

MagFlux Q 8200 Series

Solenoid Valve DF-SB-series

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

SATRON VTe pressure transmitter

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Modulating Control Valve PN 16 with Magnetic Actuator

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Vortex Eggs Delta Flowmeter

VHS... Screw Flow Meter

Pressure transmitters for heavy duty applications MBS 3200 and 3250

JUMO MIDAS Pressure transmitter

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Magnetic-inductive flow meter for hazardous areas

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

Solenoid Valve DF-SA-series

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

Condensed Catalog 2006 North America

G2 Industrial Grade Meters

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Flow switches Series AD/VH

GRUNDFOS DATA BOOKLET. Self-priming multistage pumps 50 Hz

Solenoid Valve ST-IA-series

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure transmitters for heavy duty applications Type MBS 3250

Differential Pressure Sensors

Solenoid valves VZWM-L, NPT

Turbine flowmeters Series TM

Metal tube variable area flowmeter for gases, liquids and steam

CTE7000 / CTU7000 Series Miniature pressure transmitters

SATRON VDt Differential Pressure Transmitter

Digital ph transmitter

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

Inductive conductivity meter

Solenoid Valve ST-SA-series

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Transcription:

GRUNDFOS DATA BOOKLET Grundfos Direct Sensors Vortex flow sensors

Grundfos Direct Sensors Table of contents 1. Vortex flow sensors 3 Introduction 3 2. Vortex flow sensor, industry (VFI) 4 VFI general data 4 VFI 0.3-6 DN 18, technical data 6 VFI 0.6-12 DN 25, technical data 7 VFI 1.3-25 DN 32, technical data 8 VFI 2-40 DN 40, technical data 9 VFI 3.2-64 DN 50, technical data 10 VFI 5.2-104 DN 65, technical data 11 VFI 8-160 DN 80, technical data 12 VFI 12-240 DN 100, technical data 13 3. Vortex flow sensor, standard 14 VFS general data 14 VFS 1-20, technical data 16 VFS 2-40, technical data 17 VFS 5-100, technical data 18 VFS 10-200, technical data 19 VFS 20-400, technical data 20 VFS 1-12 QT, technical data 21 VFS 1-15 QT, technical data 22 VFS 2-40 QT, technical data 23 VFS 5-100 QT, technical data 24 VFS 10-200 QT, technical data 25 4. Product range 26 VFI sensor 26 VFS sensor 27 Sensor selection 27 5. Accessories 28 Sensor interface, type SI 001 PSU 28 Sensor interface, type SI 010 CNV 28 6. Appendix 29 Installation of VFI sensor 29 Minimum flow rate 30 Pressure drop curves 31 7. Further product documentation 32 WebCAPS 32 WinCAPS 33 2

Grundfos Direct Sensors 1 1. Vortex flow sensors Introduction This data booklet comprises an overview of the Grundfos vortex flow sensor range and related products. Fig. 1 Grundfos vortex flow sensors The trademark Grundfos Direct Sensors is owned and controlled by the Grundfos group. The Grundfos vortex flow sensor is an integrated flow and temperature measurement system designed and validated for harsh aqueous environments. The flow measurement is based on the vortex principle. The system elements include a flow pipe with an integrated bluff body and a differential pressure detector. TM04 7362 1610, TM05 4739 2412 & TM05 4746 2412 direction Fig. 2 Operating principle Bluff body Pipe The bluff body is designed to optimise the pulse strength of the pressure variations at the position of the differential pressure detector. The bluff body is an integrated part of the injection moulded flow pipe, or supplied as a composite insert solution. ranges are determined by the pipe diameter and the signal processing parameters. The differential pressure detector key elements are a bulk micromachined silicon chip and a microprocessor-based signal-conditioning circuit, both on the same PCB. The conditioning circuit converts the pressure reading to a signal proportional to the flow through the pipe. The electronics are protected by an IP44 composite housing. The chip has a square membrane, which deflects due to pressure. Strain gauges are incorporated in a Wheatstone bridge configuration on stress intensive positions on the membrane. The pressure and temperature sensitive area (the membrane region) is coated on both sides by an extremely corrosion and diffusion resistive thin film (Silicoat ). The coating provides direct environmental robustness of the chip. The separation of the media and media-free zones is provided by O-ring sealing. TM04 7155 1610 Vortex flow sensors Fig. 1 Bluff body inside a vortex flow sensor TM04 9236 3710 When a bluff body is placed in a flow inside a pipe, a series of vortices will be generated periodically on each side of the bluff body. These vortices propagate down stream giving rise to periodic pressure variations, which can be detected by the differential pressure detector. The frequency of the pressure variations is proportional to the volume flow through the pipe. 3

2 Grundfos Direct Sensors Vortex flow sensor, industry (VFI) 2. Vortex flow sensor, industry (VFI) VFI general data Vortex flow sensor, industry Fig. 3 VFI sensor Technical overview The VFI is the industrial version of the Grundfos vortex flowmeter range. The VFI is based on the principle of vortex shedding behind a bluff body. The VFI has no moving parts and is built into a stainless steel pipe. The rugged design allows the VFI to be used in a wide range of applications as a cost-effective and accurate flow sensor. The flow sensors are supplied with flanges or with threaded ends for use with union nuts. TM04 7362 2210 Features range from 0.3 to 240 m 3/ h based on the vortex principle compact and well-proven design approved for drinking water wide temperature range. Benefits No moving parts compatible with wet, aggressive media cost-effective and robust design system solution with Grundfos pumps. Approvals WRAS KTW ACS NSF 61. Markings + 75 CE c, CSA, us C-Tick Electrical connections TM04 9228 3710 2 1 Fig. 4 Bluff body in a VFI sensor 4 Applications Water treatment and distribution light chemical industry water management pool and water resorts heating air-conditioning cooling towers condensing units solar collectors. Fig. 5 Electrical connections PIN 1 2 3 4 Wire colour Brown White Blue Black Output 4-20 ma + - Power supply: 12.5-30 V (screened cable) Type: Loop-powered, 2-wire 3 TM04 7156 1610 4

Grundfos Direct Sensors 2 Type key Type designation VFI - 0.3-6 m -1 -C -M 5.000 X -FG6 -SG -30 F -A 1 Product group: VFI: Vortex flow sensor, industry Range: 0.3-6 Unit: m: m 3 /h Generation: 1: 1st generation Electrical output type: C: 4-20 ma, 2-wire Sensor connector or cable type and cable connector in sensor end: M: M12x1, female straight, screened 4-wire cable Cable length5.000= 5 m Cable connector opposite sensor: X: Open-ended Sealing material and class: First letter: E: EPDM (drinking-water approved) F: FKM (for use in oily media) Second letter: G: Gel-filled Third letter: 6: IP67 Material: B: Brass C: Composite G: Cast iron Q: Stainless steel flow pipe with composite insert (QT) S: Stainless steel Dimension of mechanical connection: 30: DIN PN25/40 DN18/25/32, ANSI B16.5 Class 300-1¼" Mechanical connection type: F: Flange Packaging: A: Set with pre-assembled components 1: 1 piece Vortex flow sensor, industry (VFI) 5

2 Grundfos Direct Sensors Vortex flow sensor, industry (VFI) VFI 0.3-6 DN 18, technical data Vortex flow sensor, industry, 0.3-6 m³/h Fig. 6 Fig. 7 VFI 0.3-6 sensor VFI sensor with flanges Flange material Flange Cast iron DN 25/32 (PN 40) A B C Flanges are compatible with DN 25/32 flanges sizes. D TM047142 1710 / TM04 4250 1710 TM04 7154 1610 Weight [kg] 4.38 200 18 120 140 Stainless steel 4.44 Measuring range 0.3-6 m³/h* Accuracy (±1σ), 0-100 C ± 1.5 % FS* Response time < 1 s 0.0075 m³/h Liquid types See appendix Minimum flow rate Liquid max. pressure 28 bar Liquid temperature -30-120 C, non-freezing Liquid temperature -30-120 C, non-freezing 55-70 C Storage temperature 55-70 C 0-95 % RH, non-condensing 60 bar Power supply 12.5-30 VDC (± 5 %) - cut off 4-20 ma 21 ma Max. 660 mw Max. 60 Ω at 12.5 VDC Max. 100 Ω at 13.3 VDC Max. 600 Ω at 24 VDC Max. 900 Ω at 30 VDC Measurement element Packing material EPDM or FKM rubber Sensor housing Stainless steel 1.4404 pipe Stainless steel 1.4408 Bluff body Stainless steel 1.4401 Corrosion-resistant coating EPDM or FKM rubber Stainless steel 1.4401/04/08 IP67 20-2000 Hz, 10G, 4h *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s TM04 7153 1610 21 ma Signal cut off Fig. 8 VFI sensor with thread Material Thread size A B C Weight [kg] Stainless steel G1 1/4" 200 18 120 1.39 The VFI sensor with threaded ends must be mounted with union nuts. 4 ma Qmin Qmax TM04 7534 1210 Fig. 9 response 6

Grundfos Direct Sensors 2 VFI 0.6-12 DN 25, technical data Vortex flow sensor, industry, 0.6-12 m³/h Fig. 10 VFI 0.6-12 sensor Fig. 11 VFI sensor with flanges Flange material Flange size A B C Flanges are compatible with DN 25/32 flanges sizes. D TM047143 1710 / TM04 4251 1710 TM04 7154 1610 Weight [kg] 4.52 Cast iron DN 25/32 200 18 124 140 Stainless steel (PN 40) 4.58 Measuring range 0.6-12 m³/h* Accuracy (±1σ), 0-100 C ± 1.5 % FS* Response time < 1 s 0.015 m³/h Liquid types See appendix Minimum flow rate Liquid max. pressure 28 bar Liquid temperature -30-120 C, non-freezing Liquid temperature -30-120 C, non-freezing 55-70 C Storage temperature 55-70 C 0-95 % RH, non-condensing 60 bar Power supply 12.5-30 VDC (± 5 %) - cut off 4-20 ma 21 ma Max. 660 mw Max. 60 Ω at 12.5 VDC Max. 100 Ω at 13.3 VDC Max. 600 Ω at 24 VDC Max. 900 Ω at 30 VDC Measurement element Packing material EPDM or FKM rubber Sensor housing Stainless steel 1.4404 pipe Stainless steel 1.4408 Bluff body Stainless steel 1.4401 Corrosion-resistant coating EPDM or FKM rubber Stainless steel 1.4401/04/08 IP67 20-2000 Hz, 10G, 4h Vortex flow sensor, industry (VFI) Fig. 12 VFI sensor with thread TM04 7153 1610 *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s 21 ma Signal cut off Material Thread size A B C Weight [kg] Stainless steel G1 1/4" 200 18 124 1.53 The VFI sensor with threaded ends must be mounted with union nuts. 4 ma Qmin Qmax TM04 7534 1210 Fig. 13 response 7

2 Grundfos Direct Sensors Vortex flow sensor, industry (VFI) VFI 1.3-25 DN 32, technical data Vortex flow sensor, industry, 1.3-25 m³/h Fig. 14 VFI 1.3-25 sensor Fig. 15 VFI sensor with flanges Flange material Flange size A B C Flanges are compatible with DN 25/32 flanges sizes. D TM047144 1710 / TM04 4252 1710 TM04 7154 1610 Weight [kg] 4.47 Cast iron DN 25/32 200 18 128 140 Stainless steel (PN 40) 4.53 Measuring range 1.3-25 m³/h* Accuracy (±1σ), 0-100 C ± 1.5 % FS* Response time < 1 s 0.03125 m³/h Liquid types See appendix Minimum flow rate Liquid max. pressure 28 bar Liquid temperature -30-120 C, non-freezing Liquid temperature -30-120 C, non-freezing 55-70 C Storage temperature 55-70 C 0-95 % RH, non-condensing 60 bar Power supply 12.5-30 VDC (± 5 %) - cut off 4-20 ma 21 ma Max. 660 mw Max. 60 Ω at 12.5 VDC Max. 100 Ω at 13.3 VDC Max. 600 Ω at 24 VDC Max. 900 Ω at 30 VDC Measurement element Packing material EPDM or FKM rubber Sensor housing Stainless steel 1.4404 pipe stainless steel 1.4408 Bluff body stainless steel 1.4401 Corrosion-resistant coating EPDM or FKM rubber Stainless steel 1.4401/04/08 IP67 20-2000 Hz, 10G, 4h Fig. 16 VFI sensor with thread TM04 7153 1610 *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s 21 ma Signal cut off Matreial Thread size A B C Weight [kg] Stainless steel G 1 1/2" 200 19 128 1.31 The VFI sensor with threaded ends must be mounted with union nuts. 4 ma Qmin Qmax TM04 7534 1210 Fig. 17 response 8

Grundfos Direct Sensors 2 VFI 2-40 DN 40, technical data Vortex flow sensor, industry, 2-40 m³/h Fig. 18 VFI 2-40 sensor Fig. 19 VFI sensor with flanges Flange material Flange size A B C Flanges are compatible with DN 40 flanges sizes. D TM047145 1710 TM04 7154 1610 Weight [kg] 5.58 Cast iron DN 40 200 18 131 150 Stainless steel (PN 40) 6.45 Measuring range 2-40 m³/h* Accuracy (±1σ), 0-100 C ± 1.5 % FS* Response time < 1 s 0.05 m³/h Liquid types See appendix Minimum flow rate Liquid max. pressure 28 bar Liquid temperature -30-120 C, non-freezing Liquid temperature -30-120 C, non-freezing 55-70 C Storage temperature 55-70 C 0-95 % RH, non-condensing 60 bar Power supply 12.5-30 VDC (± 5 %) - cut off 4-20 ma 21 ma Max. 660 mw Max. 60 Ω at 12.5 VDC Max. 100 Ω at 13.3 VDC Max. 600 Ω at 24 VDC Max. 900 Ω at 30 VDC Measurement element Packing material EPDM or FKM rubber Sensor housing Stainless steel 1.4404 pipe Stainless steel 1.4408 Bluff body Stainless steel 1.4401 Corrosion-resistant coating EPDM or FKM rubber Stainless steel 1.4401/04/08 IP67 20-2000 Hz, 10G, 4h Vortex flow sensor, industry (VFI) *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s 21 ma Signal cut off 4 ma Qmin Qmax TM04 7534 1210 Fig. 20 response 9

2 Grundfos Direct Sensors Vortex flow sensor, industry (VFI) VFI 3.2-64 DN 50, technical data Vortex flow sensor, industry, 3.2-64 m³/h Fig. 21 VFI 3.2-64 sensor Fig. 22 VFI sensor with flanges Flange material Flange size A B C Flanges are compatible with DN 50 flanges sizes. D TM047146 1710 TM04 7154 1610 Weight [kg] 6.94 Cast iron DN 50 200 22 138 165 Stainless steel (PN 40) 5.94 Measuring range 3.2-64 m³/h* Accuracy (±1σ), 0-100 C ± 1.5 % FS* Response time < 1 s 0.08 m³/h Liquid types See appendix Minimum flow rate Liquid max. pressure 28 bar Liquid temperature -30-120 C, non-freezing Liquid temperature -30-120 C, non-freezing 55-70 C Storage temperature 55-70 C 0-95 % RH, non-condensing 60 bar Power supply 12.5-30 VDC (± 5 %) - cut off 4-20 ma 21 ma Max. 660 mw Max. 60 Ω at 12.5 VDC Max. 100 Ω at 13.3 VDC Max. 600 Ω at 24 VDC Max. 900 Ω at 30 VDC Measurement element Packing material EPDM or FKM rubber Sensor housing Stainless steel 1.4404 pipe Stainless steel 1.4408 Bluff body Stainless steel 1.4401 Corrosion-resistant coating EPDM or FKM rubber Stainless steel 1.4401/04/08 IP67 20-2000 Hz, 10G, 4h *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s 21 ma Signal cut off 4 ma Qmin Qmax TM04 7534 1210 Fig. 23 response 10

Grundfos Direct Sensors 2 VFI 5.2-104 DN 65, technical data Vortex flow sensor, industry, 5.2-104 m³/h Fig. 24 VFI 5.2-104 sensor Fig. 25 VFI sensor with flanges Flange material Flange size A B C Flanges are compatible with DN 65 flanges sizes. D TM047147 1710 TM04 7154 1610 Weight [kg] 9.31 Cast iron DN 65 200 25 145 185 Stainless steel (PN 40) 9.9 Measuring range 5.2-104 m³/h* Accuracy (±1σ), 0-100 C ± 1.5 % FS* Response time < 1 s 0.13 m³/h Liquid types See appendix Minimum flow rate Liquid max. pressure 28 bar Liquid temperature -30-120 C, non-freezing Liquid temperature -30-120 C, non-freezing 55-70 C Storage temperature 55-70 C 0-95 % RH, non-condensing 60 bar Power supply 12.5-30 VDC (± 5 %) - cut off 4-20 ma 21 ma Max. 660 mw Max. 60 Ω at 12.5 VDC Max. 100 Ω at 13.3 VDC Max. 600 Ω at 24 VDC Max. 900 Ω at 30 VDC Measurement element Packing material EPDM or FKM rubber Sensor housing Stainless steel 1.4404 pipe Stainless steel 1.4408 Bluff body Stainless steel 1.4401 Corrosion-resistant coating EPDM or FKM rubber Stainless steel 1.4401/04/08 IP67 20-2000 Hz, 10G, 4h Vortex flow sensor, industry (VFI) *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s 21 ma Signal cut off 4 ma Qmin Qmax TM04 7534 1210 Fig. 26 response 11

2 Grundfos Direct Sensors Vortex flow sensor, industry (VFI) VFI 8-160 DN 80, technical data Vortex flow sensor, industry, 8-160 m³/h Fig. 27 VFI 8-160 sensor Fig. 28 VFI sensor with flanges Flange material Cast iron Flange size DN80 (PN40) A B C Flanges are compatible with DN 80 flanges sizes. D TM047148 1710 TM04 7154 1610 Weight [kg] 11,51 200 25 152 235 Stainless steel 16 Measuring range 8-160 m³/h* Accuracy (±1σ), 0-100 C ± 1.5 % FS* Response time < 1 s 0.2 m³/h Liquid types See appendix Minimum flow rate Liquid max. pressure 28 bar Liquid temperature -30-120 C, non-freezing Liquid temperature -30-120 C, non-freezing 55-70 C Storage temperature 55-70 C 0-95 % RH, non-condensing 60 bar Power supply 12.5-30 VDC (± 5 %) - cut off 4-20 ma 21 ma Max. 660 mw Max. 60 Ω at 12.5 VDC Max. 100 Ω at 13.3 VDC Max. 600 Ω at 24 VDC Max. 900 Ω at 30 VDC Measurement element Packing material EPDM or FKM rubber Sensor housing Stainless steel 1.4404 pipe Stainless steel 1.4408 Bluff body Stainless steel 1.4401 Corrosion-resistant coating EPDM or FKM rubber Stainless steel 1.4401/04/08 IP67 20-2000 Hz, 10G, 4h *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s 21 ma Signal cut off 4 ma Qmin Qmax TM04 7534 1210 Fig. 29 response 12

Grundfos Direct Sensors 2 VFI 12-240 DN 100, technical data Vortex flow sensor, industry, 12-240 m³/h Fig. 30 VFI 12-240 sensor Fig. 31 VFI sensor with flanges Flange material Flange size A B C Flanges are compatible with DN 100 flanges sizes. D TM047149 1710 TM04 7154 1610 Weight [kg] 13.56 Cast iron DN 100 250 25 163 220 Stainless steel (PN 16) 14.00 Measuring range 12-240 m³/h* Accuracy (±1σ), 0-100 C ± 1.5 % FS* Response time < 1 s 0.30 m³/h Liquid types See appendix Minimum flow rate Liquid max. pressure 16 bar Liquid temperature -30-120 C, non-freezing Liquid temperature -30-120 C, non-freezing 55-70 C Storage temperature 55-70 C 0-95 % RH, non-condensing 60 bar Power supply 12.5-30 VDC (± 5 %) - cut off 4-20 ma 21 ma Max. 660 mw Max. 60 Ω at 12.5 VDC Max. 100 Ω at 13.3 VDC Max. 600 Ω at 24 VDC Max. 900 Ω at 30 VDC Measurement element Packing material EPDM or FKM rubber Sensor housing Stainless steel 1.4404 pipe Stainless steel 1.4408 Bluff body Stainless steel 1.4401 Corrosion-resistant coating EPDM or FKM rubber Stainless steel 1.4401/04/08 IP67 20-2000 Hz, 10G, 4h Vortex flow sensor, industry (VFI) *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s 21 ma Signal cut off 4 ma Qmin Qmax TM04 7534 1210 Fig. 32 response 13

3 Grundfos Direct Sensors Vortex flow sensor, standard 3. Vortex flow sensor, standard VFS general data Vortex flow sensor, standard TM05 4745 2412 Type key Product number Version Production year and week Consecutive number 96xxxxxx - XX - XXXX XXXXX For more information. see http://www.grundfos.com/directsensors. Electrical connections Fig. 33 VFS and VFS QT Sensors Technical overview Grundfos Direct Sensors, type VFS, is a series of combined flow- and temperature sensors (two-in-one) based on the principle of vortex shedding behind a bluff body. The VFS sensors are designed for high-volume production and are fully compatible with wet, aggressive media. The VFS sensor utilises MEMS sensing technology in combination with a novel packaging concept using corrosion-resistant coating on the MEMS sensor element. This makes the VFS sensor very robust and ideal for high-volume OEM applications. Applications Thermal management in solar heating systems industrial process flow control flow rate detection for pump controls monitoring of pumps, valves and filters temperature control domestic hot-water systems heat metering indication (solar heat pumps). Features ranges: 1-12, 1-15, 1.3-20, 2-40, 5-100, 10-200 and 20-400 l/min. designed to operate in glycol mixture based on vortex shedding voltage output (ratiometric, ideal for use with microprocessor and PLC) compact and robust design approved for drinking water: WRAS, KTW, W270, ACS SiliCoat technology. Benefits No moving parts flow- and temperature sensor in one package (two-in-one sensor) quick temperature response (direct media contact) compatible with wet, aggressive media cost-effective and robust construction. Temperature signal signal Fig. 34 Electrical connections V 1 V 2 PE 3 Pin configuration Colour 1 Temperature signal (0.5 to 3.5 V relative to pin 3) Yellow 2 signal (0.5 to 3.5 V relative to pin 3) White 3 GND (0 V), PELV Green 4 Power supply (+ 5 V DC) Brown Power supply requirements 5 VDC ±5% max. 10 mv ripple, 50 Hz min. output current 10 ma separated from hazardous live circuitry by double or reinforced insulation power limitation: 150 VA; current limitation: 8 A. Directives The Grundfos Vortex flow sensors are in conformity with these Council directives on the approximation of the laws of the EC member states: Low Voltage Directive (2006/95/EC) Standards used: EN 61010-1:2001 EMC Directive (2004/108/EC) Standards used: EN 61326-1:2006 and 61326-2-3:2006 The Grundfos Vortex flow sensors fall under Article 3, 3 of PED Directive 97/23/EEC and are therefore not required to be CE-marked according to this directive. 4 Electrical connector Pin No Pipe system TM04 7156 1610 14

Grundfos Direct Sensors 3 VFS Sensors Sensor and cable connection Vortex flow sensor, standard Fig. 37 Sensor and cable TM05 4749 2512 Fig. 35 VFS family TM05 4744 2512 VFS flow sensors consist of a composite flow pipe and a sensor with cable. The VFS are available in 1-20, 2-40, 5-100, 10-200, 20-400 l/min versions. VFS QT sensors Fig. 36 VFS QT family TM05 4743 2512 VFS QT flow sensors consist of a composite insert, a stainless steel outer pipe and a sensor with cable. The VFS QT are availiable in 1-12, 1-15, 2-40, 5-100, 10-200 l/min versions. 15

3 Grundfos Direct Sensors Vortex flow sensor, standard VFS 1-20, technical data Vortex flow sensor, standard, 1-20 l/min TM05 4751 2512 Temperature output signal (V) Temperature ( C) Fig. 42 Temperature response TM03 8149 0607 Fig. 38 VFS 1-20 sensor Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Response time (63.2 %) 1.3-20 l/min 1.3-20 l/min ±1.5 % FS ± 5 % FS (typical ±3% FS) < 1s 0.1 l/min Temperature TM05 4669 2512 Measuring range 0-100 C Accuracy (±1σ), 25-80 C ±1 C Accuracy (±1σ), 0-100 C ±2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C Fig. 39 Dimensional sketches of sensing element Media types The sensor is compatible with liquids (kinematic viscosity 2 mm 2 /s) Fig. 40 Dimensional sketch of flow pipe TM03 8205 0807 Media temperature Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing Media temperature (peak) 120 C for 5 minutes, up to 3 weeks in sensor lifetime (peak) 55-90 C 0-95 % (relative), non-condensing > 16 bar Power supply 5 V DC (± 5 %). Grounding of the sensor supply is recommended (PELV) Ratiometric signal 0.35-3.5 V (Zero at 0.35 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω output signal (V) (l/min) TM03 8206 0807 Seal (sensor to housing) EPDM rubber Housing Composites (PPS, PA66) pipe PPA 40-GF Corrosion-resistant coating, EPDM, PPS, PPA 40-GF IP44 (Not overmoulded IP20) 20-2000 Hz, 10G, 4h Fig. 41 response 47 x 40 x 20 mm, see drawing pipe 82 x 39 x 25 mm 16

Grundfos Direct Sensors 3 VFS 2-40, technical data Vortex flow sensor, standard, 2-40 l/min TM05 4749 2512 Temperature output signal (V) Temperature ( C) Fig. 47 Temperature response TM03 8149 0607 Vortex flow sensor, standard Fig. 43 VFS 2-40 sensor Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Response time (63.2 %) 2-40 l/min 2-40 l/min ±1.5 % FS ± 5 % FS (typical ±3% FS) < 1 s 0.2 l/min Temperature TM05 4669 2512 Measuring range 0-100 C Accuracy (±1σ), 25-80 C ±1 C Accuracy (±1σ), 0-100 C ±2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C Fig. 44 Dimensional sketches of sensing element Media types The sensor is compatible with liquids (kinematic viscosity 2 mm 2 /s) Fig. 45 Dimensional sketch of flow pipe TM03 8204 0807 Media temperature Media temperature (peak) (peak) Power supply Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing 120 C for 5 minutes, up to 3 weeks in sensor lifetime 55-90 C 0-95 % (relative), non-condensing > 16 bar 5 V DC (± 5 %). Grounding of the sensor supply is required (PELV) Ratiometric signal 0.5-3.5 V (Zero at 0.35 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω output signal (V) (l/min) Fig. 46 response TM03 8216 0807 Seal (sensor to housing) EPDM rubber Housing Composites (PPS, PA66) pipe PPA 40-GF Corrosion-resistant coating, EPDM, PPS, PPA 40-GF IP44 (Non overmoulded IP20) 20-2000 Hz, 10G, 4h 47 x 40 x 20 mm, see drawing pipe 88 x 39 x 25 mm 17

3 Grundfos Direct Sensors Vortex flow sensor, standard VFS 5-100, technical data Vortex flow sensor, standard, 5-100 l/min TM05 4748 2512 Temperature output signal (V) Temperature ( C) Fig. 52 Temperature response TM03 8149 0607 Fig. 48 VFS 5-100 sensor Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Response time (63.2 %) 5-100 l/min 5-100 l/min ±1.5 % FS ± 5 % FS (typical ±3% FS) < 1 s 0.5 l/min Temperature TM05 4669 2512 Measuring range 0-100 C Accuracy (±1σ), 25-80 C ±1 C Accuracy (±1σ), 0-100 C ±2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C Fig. 49 Dimensional sketches of sensing element Media types The sensor is compatible with liquids (kinematic viscosity 2 mm 2 /s) 2xISO 228/1-G 1A Fig. 50 Dimensional sketch of flow pipe TM03 8219 0807 Media temperature Media temperature (peak) (peak) Power supply Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing 120 C for 5 minutes, up to 3 weeks in sensor lifetime 55-90 C 0-95 % (relative), non-condensing > 16 bar 5 V DC (±5 %). Grounding of the sensor supply is required (PELV) Ratiometric signal 0.5-3.5 V (Zero at 0.35 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω output signal (V) (l/min) Fig. 51 response TM03 8217 0807 Seal (sensor to housing) EPDM rubber Housing Composites (PPS, PA66) pipe PPA 40-GF Corrosion-resistant coating, EPDM, PPS, PPA 40-GF IP44 (Non overmoulded IP20) 20-2000 Hz, 10G, 4h 47 x 40 x 20 mm, see drawing pipe 129 x 37 x 32 mm 18

Grundfos Direct Sensors 3 VFS 10-200, technical data Vortex flow sensor, standard, 10-200 l/min Fig. 53 VFS 10-200 sensor TM05 4747 2512 Temperature output signal (V) Fig. 57 Temperature response Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Temperature ( C) 10-200 l/min 10-200 l/min ±1.5 % FS ± 5 % FS (typical ±3% FS) TM03 8149 0607 Vortex flow sensor, standard Response time (63.2 %) < 1.0 s 1.0 l/min Temperature Fig. 54 Dimensional sketches of sensing element 2xISO 228/1-G 1¼ A TM05 4669 2512 Measuring range 0-100 C Accuracy (± 1σ), 25-80 C ± 1 C Accuracy (± 1σ), 0-100 C ± 2 C Response time (63.2 %) 250 ms 0.35 C Media types The sensor is compatible with liquids (kinematic viscosity 2 mm 2 /s) Media temperature Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing Media temperature (peak) 120 C for 5 minutes, up to 3 weeks in sensor lifetime (peak) 55-90 C 0-95 % RH, non-condensing > 16 bar Fig. 55 Dimensional sketch of flow pipe TM03 8204 0807 Power supply 5 VDC (± 5 %). Grounding of the sensor supply is required (PELV) Ratiometric signal 0.5-3.5 V (Zero at 0.35 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω Seal (sensor to housing) EPDM rubber Housing Composites (PPS, PA66) output signal (V) (l/min) Fig. 56 response TM03 8216 0807 pipe PPA 40-GF Corrosion-resistant coating, EPDM, PPS, PPA 40-GF IP44 (Non overmoulded IP20) 20-2000 Hz, 10G, 4h 47 x 40 x 20 mm, see drawings pipe 137 x 45 x 41 mm 19

3 Grundfos Direct Sensors Vortex flow sensor, standard VFS 20-400, technical data Vortex flow sensor, standard, 20-400 l/min Fig. 58 VFS 20-400 sensor TM05 4746 2512 Temperature output signal (V) Fig. 62 Temperature response Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Response time (63.2 %) Temperature ( C) 20-400 l/min 20-400 l/min ±1.5 % FS ± 5 % FS (typical ±3% FS) < 1.0 s 2.0 l/min TM03 8149 0607 Temperature TM05 4669 2512 Measuring range 0-100 C Accuracy (± 1σ), 25-80 C ± 1 C Accuracy (± 1σ), 0-100 C ± 2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C Fig. 59 Dimensional sketches of sensing element 2xISO 228/1-G 1½ Fig. 60 Dimensional sketch of flow pipe TM04 2954 3308 Media types The sensor is compatible with liquids (kinematic viscosity 2 mm 2 /s) Media temperature Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing Media temperature (peak) 120 C for 5 minutes, up to 3 weeks in sensor lifetime (peak) 55-90 C 0-95 % RH, non-condensing > 16 bar Power supply 5 VDC (± 5 %). Grounding of the sensor supply is required (PELV) Ratiometric signal 0.5-3.5 V (Zero at 0.35 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω output signal (V) 100 200 300 400 (l/min) TM03 8218 0807 Seal (sensor to housing) EPDM rubber Housing Composites (PPS, PA66) pipe PPA 40-GF Corrosion-resistant coating, EPDM, PPS, PPA 40-GF IP44 (Non-overmoulded IP20) 20-2000 Hz, 10G, 4h Fig. 61 response pipe 47 x 40 x 20 mm, see drawings 180 x 54 x 48 mm 20

Grundfos Direct Sensors 3 VFS 1-12 QT, technical data Vortex flow sensor, standard, 1-12 l/min Fig. 63 VFS 1-12 sensor TM05 4742 2512 Temperature output signal (V) Temperature ( C) Fig. 66 Temperature response TM03 8149 0607 Vortex flow sensor, standard Fig. 64 Dimensional sketches of VFS QT output signal (V) 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 (l/min) Fig. 65 response TM005 4671 2512 TM005 4670 2512 TM03 2465 2108 Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Response time (63.2 %) Temperature 1-12 l/min 1-12 l/min ± 1.5 % FS ± 5.0 % FS (typical 3%) < 3 sec. 0.06 l/min Measuring range 0-100 C Accuracy (±1σ), 25-80 C ± 1 C Accuracy (±1σ), 0-100 C ± 2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C Media types The sensor is compatible with liquids (kinematic viscosity 4 mm 2 /s) Media temperature Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing Media temperature (peak) 120 C for 5 minutes, up to 3 weeks in sensor lifetime (peak) 55-90 C 0-95 % (relative), non-condensing > 16 bar Power supply 5 V DC (± 5 %). Grounding of the sensor supply is required (PELV) Ratiometric signal 0.5-3.5 V (Zero at 0.25 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω Seal (sensor to housing) EPDM rubber Housing Composites (PPS, PA66) Vortex tube 1.4408 Insert PPA 40 GF Corrosion-resistant coating EPDM, PPS, PPA 40-GF, 1.4408 IP44 (Non overmoulded IP20) 20-2000 Hz, 10G, 4h 47 x 40 x 20 mm, see drawing Vortex tube 110 x 29.8 x 31.5 mm Insert 63.9 x 16 x 15.4 mm 21

3 Grundfos Direct Sensors Vortex flow sensor, standard VFS 1-15 QT, technical data Vortex flow sensor, standard, 1-15 l/min Fig. 67 VFS 1-15 sensor TM05 4742 2512 Temperature output signal (V) Temperature ( C) Fig. 70 Temperature response TM03 8149 0607 Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Response time (63.2 %) 1-15 l/min 1-15 l/min ± 1.5 % FS ± 5.0 % FS (typical 3%) < 1 sec. 0.075 l/min Temperature TM005 4671 2512 Measuring range 0-100 C Accuracy (±1σ), 25-80 C ± 1 C Accuracy (±1σ), 0-100 C ± 2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C TM005 4670 2512 Media types The sensor is compatible with liquids (kinematic viscosity 2 mm 2 /s) Media temperature Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing Media temperature (peak) 120 C for 5 minutes, up to 3 weeks in sensor lifetime (peak) 55-90 C 0-95 % (relative), non-condensing > 16 bar Fig. 68 Dimensional sketches of VFS QT output signal (V) 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 5 10 (l/min) Fig. 69 response 15 TM05 3706 1612 Power supply 5 V DC (± 5 %). Grounding of the sensor supply is required (PELV) Ratiometric signal 0.5-3.5 V (Zero at 0.25 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω Seal (sensor to housing) EPDM rubber Housing Composites (PPS, PA66) Vortex tube 1.4408 Insert PPA 40 GF Corrosion-resistant coating EPDM, PPS, PPA 40-GF, 1.4408 IP44 (Non overmoulded IP20) 20-2000 Hz, 10G, 4h Vortex tube Insert 47 x 40 x 20 mm, see drawing 110 x 29.8 x 31.5 mm 63.9 x 16 x 15.4 mm 22

Grundfos Direct Sensors 3 VFS 2-40 QT, technical data Vortex flow sensor, standard, 2-40 l/min TM05 4741 2512 Temperature output signal (V) Fig. 74 Temperature response Temperature ( C) TM03 8149 0607 Vortex flow sensor, standard Fig. 71 VFS 2-40 sensor Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) 2-40 l/min ± 1.5 % FS ± 5.0 % FS (typical 3%) Response time (63.2 %) < 1 sec. 0.2 l/min Temperature Fig. 72 Dimensional sketches of VFS QT TM005 4670 2512 TM005 4671 2512 Measuring range 0-100 C Accuracy (±1σ), 25-80 C ±1 C Accuracy (±1σ), 0-100 C ±2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C Media types The sensor is compatible with liquids (kinematic viscosity 2 mm²/s). Media temperature Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing Media temperature (peak) 120 C for 5 minutes, up to 3 weeks in sensor lifetime (peak) 55-90 C 0-95 % (relative), non-condensing > 16 bar Power supply 5 V DC (±5 %). Grounding of the sensor supply is required (PELV) Ratiometric signal 0.5-3.5 V (zero at 0.35 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω output signal (V) (l/min) TM03 8216 0807 Seal (sensor to housing) EPDM rubber Housing Composites (PPS, PA66) Vortex tube 1.4408 Insert PPA 40 GF Corrosion-resistant coating, EPDM, PPS, PPA 40-GF, 1.4408 IP44 (Non overmoulded IP20) 20-2000 Hz, 10G, 4h Fig. 73 response 47 x 40 x 20 mm, see drawing Vortex tube 110 x 29.8 x 31.5 mm Insert 63.9 x 16 x 15.4 mm 23

3 Grundfos Direct Sensors Vortex flow sensor, standard VFS 5-100 QT, technical data Vortex flow sensor, standard, 5-100 l/min Fig. 75 VFS 5-100 sensor TM05 4740 2512 TM005 4672 2512 Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Response time (63.2 %) Temperature 5-100 l/min ± 1.5 % FS ± 5.0 % FS (typical 3%) < 1 s 0.5 l/min Measuring range 0-100 C Accuracy (±1σ), 25-80 C ±1 C Accuracy (±1σ), 0-100 C ±2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C Media types The sensor is compatible with liquids (kinematic viscosity 2 mm 2 /s) Media temperature Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing Media temperature (peak) 120 C for 5 minutes, up to 3 weeks in sensor lifetime (peak) 55-90 C 0-95 % (relative), non-condensing > 16 bar Power supply 5 V DC (±5 %). Grounding of the sensor supply is required (PELV) Ratiometric Fig. 76 Dimensional sketches of VFS QT signal 0.5-3.5 V (Zero at 0.35 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω output signal (V) (l/min) TM03 8217 0807 Seal (sensor to housing) EPDM rubber Vortex tube 1.4408 Insert PPA 40-GF Corrosion-resistant coating, EPDM, PPS, PPA 40-GF, 1.4408 IP44 (Non overmoulded IP20) 20-2000 Hz, 10G, 4h Fig. 77 response Vortex tube 47 x 40 x 20 mm, see drawing 129 x 37 x 32 mm Insert 99.2 x 23.4x 21.9 mm Temperature output signal (V) Temperature ( C) TM03 8149 0607 Fig. 78 Temperature response 24

Grundfos Direct Sensors 3 VFS 10-200 QT, technical data Vortex flow sensor, standard, 10-200 l/min Fig. 79 VFS 10-200 sensor TM05 4739 2512 TM005 4673 2512 Measuring range: In water (0-100 C) Tyfocor LS (30-100 C) Accuracy: In water (±1σ), (0-100 C) Tyfocor LS (±1σ), (0-100 C) Response time (63.2 %) Temperature 10-200 l/min ± 1.5 % FS ± 5.0 % FS (typical 3%) < 1.0 s 1.0 l/min Measuring range 0-100 C Accuracy (± 1σ), 25-80 C ± 1 C Accuracy (± 1σ), 0-100 C ± 2 C Response time (63.2 % at 50 % FS flow) 250 ms 0.35 C Media types The sensor is compatible with liquids (kinematic viscosity 2 mm 2 /s) Media temperature Water: 0-100 C Tyfocor LS: 30-100 C 25 C, non-freezing Media temperature (peak) 120 C for 5 minutes, up to 3 weeks in sensor lifetime (peak) 55-90 C 0-95 % RH, non-condensing > 16 bar Power supply 5 VDC (± 5 %). Grounding of the sensor supply is required (PELV) Ratiometric Vortex flow sensor, standard Fig. 80 Dimensional sketches of VFS QT signal 0.5-3.5 V (Zero at 0.35 V) Temperature signal 0.5-3.5 V < 50 mw > 10 kω output signal (V) (l/min) TM03 8218 0807 Seal (sensor to housing) EPDM rubber Vortex tube 1.4408 Insert PPA 40-GF Corrosion-resistant coating, EPDM, PPS, PPA 40-GF, 1.4408 IP44 (Non overmoulded IP20) 20-2000 Hz, 10G, 4h Fig. 81 response Vortex tube 47 x 40 x 20 mm, see drawings 137 x 45 x 41 mm Insert 104.2 x 30.4 x 28.9 mm Temperature output signal (V) Temperature ( C) TM03 8149 0607 Fig. 82 Temperature response 25

4 Grundfos Direct Sensors Product range 4. Product range VFI sensor Scope of delivery: Sensor tube with sensor flanges (only for flange versions) union nuts (for threaded versions) 5 m cable with M12 connection in one end quick guide. Complete product range Pipe size EPDM O-ring FKM Cast iron flange Connection type Stainless steel flange Thread Product number VFI- 0.3-6m-1-C-M5.000X-FG6-SG-30F-A 1 97686127 VFI- 0.3-6m-1-C-M5.000X-FG6-SG-30F-A 1 97686128 VFI- 0.3-6m-1-C-M5.000X-EG6-SS-30F-A 1 97688293 0.3-6 m3/h DN 18 VFI- 0.3-6m-1-C-M5.000X-FG6-SS-30F-A 1 97688294 VFI- 0.3-6m-1-C-M5.000X-EG6-SS-07P-A 1 97688334 VFI- 0.3-6m-1-C-M5.000X-FG6-SS-07P-A 1 97688342 VFI- 0.6-12m-1-C-M5.000X-EG6-SG-30F-A 1 97686129 VFI- 0.6-12m-1-C-M5.000X-FG6-SG-30F-A 1 97686130 VFI- 0.6-12m-1-C-M5.000X-EG6-SS-30F-A 1 97688295 0.6-12 m3/h DN 25 VFI- 0.6-12m-1-C-M5.000X-FG6-SS-30F-A 1 97688296 VFI- 0.6-12m-1-C-M5.000X-EG6-SS-07P-A 1 97688335 VFI- 0.6-12m-1-C-M5.000X-FG6-SS-07P-A 1 97688343 VFI- 1.3-25m-1-C-M5.000X-EG6-SG-30F-A 1 97686141 VFI- 1.3-25m-1-C-M5.000X-FG6-SG-30F-A 1 97686142 VFI- 1.3-25m-1-C-M5.000X-EG6-SS-30F-A 1 97688297 1.3-25 m3/h DN 32 VFI- 1.3-25m-1-C-M5.000X-FG6-SG-30F-A 1 97688298 VFI- 1.3-25m-1-C-M5.000X-EG6-SS-09P-A 1 97688336 VFI- 1.3-25m-1-C-M5.000X-FG6-SS-09P-A 1 97688344 VFI- 2-40m-1-C-M5.000X-EG6-SG-31F-A 1 97686143 VFI- 2-40m-1-C-M5.000X-FG6-SG-31F-A 1 97686144 2-40 m3/h DN 40 VFI- 2-40m-1-C-M5.000X-EG6-SS-31F-A 1 97688299 VFI- 2-40m-1-C-M5.000X-FG6-SS-31F-A 1 97688300 VFI- 3.2-64m-1-C-M5.000X-EG6-SG-32F-A 1 97686145 VFI- 3.2-64m-1-C-M5.000X-FG6-SG-32F-A 1 97686146 2-64 m3/h DN 50 VFI- 3.2-64m-1-C-M5.000X-EG6-SS-32F-A 1 97688301 VFI- 3.2-64m-1-C-M5.000X-FG6-SS-32F-A 1 97688302 VFI-5.2-104m-1-C-M5.000X-EG6-SG-33F-A 1 97686147 VFI-5.2-104m-1-C-M5.000X-FG6-SG-33F-A 1 97686148 5.2-104 m3/h DN 65 VFI-5.2-104m-1-C-M5.000X-EG6-SS-33F-A 1 97688303 VFI-5.2-104m-1-C-M5.000X-FG6-SS-33F-A 1 97688304 VFI- 8-160m-1-C-M5.000X-EG6-SG-35F-A 1 97686149 VFI- 8-160m-1-C-M5.000X-FG6-SG-35F-A 1 97686150 8-160 m3/h DN 80 VFI- 8-160m-1-C-M5.000X-EG6-SS-35F-A 1 97688305 VFI- 8-160m-1-C-M5.000X-FG6-SS-35F-A 1 97688306 VFI- 12-240m-1-C-M5.000X-EG6-SG-37F-A 1 97686151 VFI- 12-240m-1-C-M5.000X-FG6-SG-37F-A 1 97686152 12-240 m3/h DN 100 VFI- 12-240m-1-C-M5.000X-EG6-SS-37F-A 1 97688308 VFI- 12-240m-1-C-M5.000X-FG6-SS-37F-A 1 97688309 26

Grundfos Direct Sensors 4 VFS sensor Sensor selection Grundfos offers a wide range of custom-built variants of the VFS sensorthat can be customized to meet individual requirements. Due to the large variation of VFS sensors, all VFS sensors cannot be listed in one table. Therefore, the tables below give a point of selection to choose from. Be aware that not all combinations are possible. Therefore, if you have any questions regarding selection, please contact Grundfos Sensors. 6. Sealing material and enclosure class Code E F G Sealing description EPDM (drinking water approved) FPM (for use in oily media) Gel-filled Code 2 IP20 4 IP44 5 IP55 6 IP67 Product range Example of a type key: VFS - 20-400L-1-D-C1.200E- G4-CS-25P-W 1 1 2 3 4 5 6 7 8 9 10 VFS 20-400 L 1 D C1.200E G4 CS 25 P W 1 1. Product group 2. Product range and units: Product range 3. Generation: Code 4. Electrical output type: Range of unit 20-400 L: litres/min. Generation 1 1st generation 2 2nd generation 3 3rd generation Code B C D E F G Output 0-10 V 4-20 ma, 2 wires 0.5-3.5 V 0.5-4.5 V 2 x 0-10 V 4-20 ma, 3 wires 5. Cable and connectors: Middle letters: 1.200 is cable length in m First and last letters: Cable connector Code Cable connector description B FCI 90312-004LF/77138-101 C CKM 42010107/42010311, tin plated D AMP 103648-3/104479-9 E Molex 51004-0400/50011-8000 F AMP 172167-1/0-170365-1 G Tyco Val-U-Lok 794954-4/794958-2, gold plated J JST XHP-4/SXH-001T-P0.6 L Lumberg 3510-04 K02 N Lumberg 3510-04 K03 Molex 43025-0400/43030-0005, 43030-001/ Cembre P 1910M16 Q Molex 43025-0400/43030-0006 R Molex 51004-0400/50011-8000/ Cembre 1900M12 X Open ended Code B C G Q S Material:The first letter represents the flow pipe, the second represents the mechanical connection part. 7. Dimension of mechanical connection 8. Mechanical connection type 9. Packaging Material description Brass Composite Cast iron Stainless steel flow pipe with composite insert (QT) Stainless steel Code Dimension Code Dimension 03 G ½" 17 7/16" 04 G ¾" 19 18.75mm 05 G1" 21 21.5mm 06 6mm 24 1/8-27 07 G 1¼" 25 3/4-14 08 8mm 26 1-11.5 09 G 1½" 27 1 ¼ - 11.5 10 G 1½" 51 f1" - G ¾ 11 G 2½" 52 f1¼" - G 1 12 G 3" 63 G ½ with ventilation opening 13 G4" Code Description B BSPT (ISO 7/1) C Compression F Flange G Flange and BSPP (ISO 228/1) K Clips M NPSM N NPT P BSPP (ISO 228/1) S Sweat T Tube U UNF Code Description of packaging A Set with pre-assembled components P Spare parts set S Set V Service set W Blister pack, standard Grundfos cardboard N Blister pack, white cardboard 1 1 piece 10 Bulk 10 25 Bulk 25 50 Bulk 50 100 Bulk 100 500 Bulk 500 27

5 Grundfos Direct Sensors Accessories 5. Accessories Sensor interface, type SI 001 PSU SI 001 PSU from Grundfos Direct Sensors is an external power supply for Grundfos sensors and other transmitters with 24 VDC supply voltage. The power supply is to be used where the distance between the transmitter and the controller exceeds 30 m. Sensor interface, type SI 010 CNV SI 010 CNV from Grundfos Direct Sensors is an external power supply, signal amplifier and signal converter for Grundfos sensors. SI 010 CNV has built-in precision resistors enabling the transmitter to give 4-20 ma, 1-5 V and 2-10 V output signals. SI 010 CNV should be used in applications where sensors from the standard product range are used, but the controller requires a 4-20 ma input signal. Fig. 83 Sensor interface, SI 001 PSU Specification: Voltage range: 110-400 VAC frequency range: 50-60 Hz ambient temperature: -20 to +50 C enclosure class: IP54. Part Product No. Sensor interface, SI 001 PSU 96915820 TM04 4194 0809 Fig. 84 Sensor interface, SI 010 CNV Specification: Voltage range: 115-230 VAC± 10% or 24 VDC frequency range: 50-60 Hz power consumption: Max. 2.5 W ambient temperature: -20 to +50 C enclosure class: IP20. TM04 4882 2209 Part Product No. Sensor interface, SI 010 CNV 96983684 28

Grundfos Direct Sensors 6 6. Appendix Installation of VFI sensor Appendix min. 10 x D 1 min. 5 x D 1 D D min. 20 x D 1-0,05 bar (0.725 PSI) -25 to 60 C (-13 to 140 F) Max. 28 bar (406 PSI) IP67-30 to 120 C (-22 to 248 F) 0 bar TM05 2306 4811 29

6 Grundfos Direct Sensors Appendix Minimum flow rate Minimum flow rate as a function of the kinematic viscosity The minimum detectable flow rate (Q min. ) for the VFI sensors depends on the kinematic viscosity of the liquid. The chart below shows Q min as a function of the kinematic viscosity. 220 176 132 DN100 DN80 88 DN65 GPM 44 39 35 31 26 22 18 13 9 DN50 DN40 DN32 DN25 4.5 4.0 3.5 3.1 2.6 2.2 1.8 1.3 DN18 0.9 0.4 0.1 1* 10 Kinematic Viscosity [cst] TM04 8001 2710 *Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s. 30

Grundfos Direct Sensors 6 Pressure drop curves p [psi] 6.00 5.00 4.00 DN18 DN25 DN32 DN80 DN40 DN50 DN100 DN65 Appendix 3.00 2.00 1.00 0.8 0.6 0.5 0.4 0.3 0.2 0.1 0.08 0.06 0.05 0.04 0.03 0.02 0.01 0.3 0 0.4 0.6 0.8 1 1.2 1.5 2 3 4 5 6 8 10 12 15 20 30 40 50 60 80 100 150 200 300 Q [m³/h] 10 20 30 40 50 60 80 100 200 300 400 Q [US GPM] TM04 9390 4310 Reference condition: - Liquids at 20 C, 1013 mbar, ρ = 998 kg/m 3, v = 1 x 10-6 m 2 /s. 31

7 Grundfos Direct Sensors Further product documentation 7. Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Replacement CAD drawings. Catalogue This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P2, etc.) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures. Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 32

0 1 Grundfos Direct Sensors 7 Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement Further product documentation In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 85 WinCAPS CD-ROM 33

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 97790189 0912 Repl. GB The name Grundfos, the Grundfos logo, and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. GRUNDFOS A/S. DK-8850 Bjerringbro. Denmark Telephone: +45 87 50 14 00 www.grundfos.com