Table of Contents with USB programming INSTRUCTI MANUAL EN 1-09 1. Introuction 1.1. Safety Instructions. 1.. Unpacking. Description. 3.1. Design... 3.. Technical Features 3.3. Operating Principle... 3.4. Connection to FlowX3 Instruments.. 4 3. Specifications 4 3.1. Technical Data 4 3.. Dimensions.. 5 4. Installation.. 6 4.1. Location..6 4.. Mounting Position...... 6 4.3. Wiring...7 4.4. Earthing..11 5. Calibration....1 5.1. Diameter Setting..1 5.. Output Setting......1 5.3. USB Setting 13 6. Installation Fittings.... 14 7. Table. 15 8. Orering Data.. 1
1. Introuction 1.1. Safety Instructions General Statements The sensor F3.60M.S has only been esigne to measure the flow of liquis. Do not install an service the sensor without following the Instruction Manual. This sensor is esigne to be connecte to other instruments which can be hazarous if use improperly. Rea an follow all associate instrument manuals before using with this sensor. Sensor installation an wiring connections shoul only be performe by qualifie staff. Do not moify prouct construction. Installation an Commissioning Statements Remove power to the sensor before wiring any connection. Depressurize an vent the system before installing or removing the sensor. Check an confirm the chemical compatibility of the materials in contact with the liqui. Do not excee maximum temperature/pressure ata. To clean the sensor, use only chemical compatible proucts. 1.. Unpacking Please verify that the prouct is complete an without any amage. The following items must be inclue: F3.60M.S Electromagnetic Flow Sensor Instruction Manual for F3.60M.S Flow Sensor USB Manual Instruction ownloaable www.flsnet.it
. Description.1. Design The FLOWX3 NEW F3.60M.S Insertion Magmeter is suitable to measure flow rate in both metal an thermoplastic pipelines. No moving mechanical parts an the high quality materials allow the measurement of liquis where suspene solis can be present or of abrasive liquis as long as they are conuctive an homogeneous. The sensor can be assemble into the stanar FLS fitting range so it is perfectly interchangeable with the palewheel sensors. The new esign allows an accurate flow measurement over a wie ynamic range in pipe sizes from 15 (0.5 ) to 600 (4 ). The NEW F3.60M.S offer frequency output for use with FLS flow instrumentation or 4- ma output for long istance transmission an PLC connection... Technical Features 1) Electronic box ) PC box 3) External Earth Groun Terminal 4) Cable Glan 5) O-Ring (EPDM or FPM) 6) Sensor boy 316L SS or CuNi 7) PVDF or PEEK reaing hea.3. Operating Principle If an electrical conuctor is cause to move in a magnetic fiel, such movement inuces a voltage in the conuctor ( Faraay s law ). The magnetic coil in the boy of the instrument generates a magnetic fiel perpenicular to the flow irection. The magnetic fiel an the velocity inuce a voltage between the electroes. The voltage is irectly proportional to the flow velocity. The voltage is converte into a flow proportional 4- ma output signal or frequency output signal. 3
.4. Connections to FlowX3 Instruments FlowX3 Instruments FlowX3 Sensors F9.00 F9.0 F9.03 F9. F9. F9.51 F3.60M.S X X X X 3. Specifications 3.1. Technical Data General Pipe Size Range: 15 to 600 (0.5 to 4 ). Please refer to Installation Fitting section for more etails. Flow Rate Range: 0.05 to 8 m/s (0.15 to ft/s). Full Scale Range : 5 m/s (16,4 ft/s) stanar (others available ). Linearity: 1% of reaing + 1,0 cm/s Repeatability: 0.5% of reaing Enclosure: IP65 Materials: o Case: PC/PVC o Gasket: EPDM Wette Materials: o Sensor boy: 316L SS/PVDF or 316L SS/PEEK or CuNi/PVDF o O-rings: EPDM or FPM o Electroes: 316L SS or CuNi Electrical Power Supply: o 4 VDC ± 10% regulate (reverse polarity an short circuit protecte) o Maximum current consumption: 1 ma o Protective earth: < 10 Ω Current output: o 4 ma, isolate o Max. loop impeance: 600 Ω @ 4 VDC o Positive or negative flow inication Frequency output: o Type: Open Collector NPN o Frequency: 0 0 Hz o Max. Pull-up Voltage: 4 VDC o Max. Current: ma, current limite o Compatible with FLOWX3 F9.0, F9.03, F9. an F9.51 Digital outputs: o Type: Open Collector NPN o Max. Pull-up Voltage: 4 VDC o Max. Current: ma, current limite o Flow irection: 0 VDC arrow-wise + VDC anti arrow-wise o Empty pipe: 0 VDC for normal working conition + VDC for empty pipe alarm EMPTY PIPE Function NOT available in this release 4
Environmental Storage Temperature: -10 C to +60 C (14 F to 1 F) Ambient Temperature: 0 C to +60 C ( F to 1 F) Relative Humiity: 0 to 95% (non-conensing) Flui conitions: o homogeneous liquis, pastes or slurries, also with soli content o Min Electrical Conuctivity: μs o Temperature: -10 C to 60 C (14 F to 1 F) with PVDF reaing hea o Temperature: -10 C to 1 C (14 F to 30 F) with PEEK reaing hea Max. operating pressure: o 16 bar @ C ( psi @ 77 F) o 8.6 bar @ 60 C (14 psi @ 1 F) Stanars & Approvals Manufacture uner ISO 9001 (Quality) Manufacture uner ISO 101 (Environmental Management) CE 3.. Dimensions 5
4. Installation 4.1. Location Different pipe configurations an obstacles in the flow line such as valves, elbows, pipe bens an strainers create variations on the flow profile. Whenever possible follow the EN ISO 5167-1 installation recommenations to locate the sensor. Always maximize istance between flow sensor an pump. 4.. Mounting Position The following configurations ensure that the pipe is always full: for a correct measurement the sensor can NOT be expose to air bubbles at any time. Avoi the following situations unless you are absolutely sure the sensor is not expose to air bubbles. 6
In gravity-flow systems the connection to the tank must be esigne so the level oes not rop below the outlet: this to avoi pipe to raw air in from the tank causing an erratic measurement of the Magmeter. 4.3. Wiring All wiring connections to F3.60M.S are mae via removable terminals. Flow sensor terminals are orange, all other terminals are green. General recommenation Always ensure the power supply is switche off before working on the evice. Terminals accept 6 to 1 AWG (0.08 to.5 mm ) Strip aroun 10 mm (0.4 ) of insulation from the wire tips an tin bare ens to avoi fraying. Ferrules are suggeste when connecting more than one wire to a single terminal. Remove the upper part of the terminals for an easy cabling. Insert wire tip or ferrule completely into the terminal an fix with the screw until finger tight. The Magmeter output signal may be unstable immeiately after the installation. Install the sensor in a full pipe for 4 hours will stabilize the performance. With a very low Electrical Conuctivity coul be necessary a longer conitioning perio. Use electrical cables with the proper external iameter for the liqui tight connector: PG11: external iameter between -7 mm (0.079-0.76 ) PG13,5: external iameter between 5-1 mm (0.197-0.47 ) 7
Rear Terminal View Power / Loop Wiring Diagram Only Frequency output version Connection to a PLC with built-in power supply (3 wire connection) 8
Connection to a PLC / Instrument with E separate power supply or Connection to a PLC / Instrument with TWO separate power supply or Open Collector Wiring Diagram Connection to FlowX3 Instruments ( Only with Frequency Output ) Connection to a PLC NPN Open Collector input 9
Connection to a PLC / Instrument igital input with separate Power Supply EMPTY PIPE Function NOT available in this release All Open Collector wiring iagrams to PLC repeat for Flow Direction an Empty pipe. Connection PC USB Magmeter Connector Magmeter G USB connector 10
4.4 Earthing The magmeter normally is uninfluence by low levels of electrical noise. In some applications it is necessary to connect the sensor to earth to eliminate electrical noise. The eathing can be one in one or more of these ifferent ways: connect a groun wire to the External Earth Groun Terminal, this terminal is internally connecte to the sensor boy. Insert metallic piping parts ( such as flange earthing rings ) into the plastic pipe before an after the magmeter an earth them together. Connect at the same earth the External Earth Groun Terminal. Flui earths must be in irect contact with the flui near to the magmeter. remote instrument Metallic evices ( valve, pump an earthing rings ) For plastic pipe applications Note: If present the shiel from the output cable must be terminate only at the remote instrument. Do not connect this shiel at both ens 11
5. Calibration The setting has to be one before powering up the instrument. 5.1. Diameter Setting The iameter can be set from 15 to 600 by the 1, an 3 switches accoring to the following table: SWITCH1 SWITCH SWITCH3 OD FROM 63 T0 FROM 1 T0 0 5.. > 0 Output Setting The analog (4 ma) or igital (frequency) output can be selecte by the switch 4: Switch 4 : Analog ( 4 ma ) : Digital ( Frequency / Pulse Output ) 1
5.3. USB Settings Through the USB interface you can change some settings of the electromagnetic. The parameters that can be varie are the following: Full Scale Average Filter Sensibility Filter Cut Off Kin Digital Output Digital Filter Bi-irectional Ajust 4 ma Ajust ma For more etails ownloa the executable an the user interface software from the site www.flsnet.it 13
6. Installation Fittings Type Description Plastic Tees Size: D to D (0.5 to 1.5 ) Materials: PVC, CPVC, PP, PVDF CPVC Clamp Sales Size: D63 to D ( to 8 ) Insert Materials: CPVC, PVDF PP Clamp Sales Size: D to D315 (10 to 1 ) Insert Material: CPVC PVC Wafer Fittings Size: D an D315 (10 an 1 ) Insert Material: CPVC GR-PP Wafer Fittings Size: D an D315 (10 an 1 ) Insert Material: CPVC Plastic Wel-on Aapters Size: D63 to D315 Materials: PVC, CPVC, PP, PE 316L SS Tees Size: D to D BSP Female Threae Size: to 4 Insert Material: CPVC Special orer for other sizes Size: D to D600 (1.5 to 4 ) 14 Metal Strap-on Sales 316L SS Wel-on Aapters
7. Table ( only for frequency output ) is the number of pulses a sensor prouces for one liter of flui measure. Here all KFactors for water at ambient temperature are liste. values can epen upon the installation conitions. Please contact your ealer for values not inclue in the table. F.S. is the Flow rate value ( L/ s ) at 5 m/sec. All is calculate with the Full Scale 5 m / sec ( to calculate the new k-factor for ifferent full scale follow the formula escribe on page 1). Installation on PVC pipes ISO Metric PVC Tee Fittings for ISO SDR 1 pipes (female ens for solvent weling) TFIVB TFIVB TFIVB TFIVB TFIVB TFIVD TFIVD TFIVD TFIVD TFIVD 15 15 PVC Glue-on Fittings WAIV063 WAIV075 65 WAIV090 WAIV WAIV1 WAIV1 1 WAIV160 1 WAIV0 1 WAIV 0 WAIV WAIV WAIV315 46,04 7,89 157,86 101,60 63,7 46,04 7,89 157,86 101,60 63,7 63 75 90 1 1 160 0 315 1,54 17,73,58 38,18 49,44 6,05,98 16,67 160, 198,46 48,60 315,19 ISO Metric Clamp Sales for ISO SDR 1 pipes (PN10 up to 90mm, PN1,5 from mm) BSP Female Threae PVC Tee Fittings for for BS PN1 pipes (parallel threae female ens) R TFFVB 15 1/" 46,04 TFFVB 3/4" 7,89 TFFVB 1" 157,86 TFFVB 1 1/4" 101,60 TFFVB 1 1/" 63,7 TFFVD 15 1/" 46,04 TFFVD 3/4" 7,89 TFFVD 1" 157,86 TFFVD 1 1/4" 101,60 TFFVD 1 1/" 63,7 SCIC063BVC SCIC075BVC SCIC090BVC SCICBVC SCIC1BVC SCIC1BVC SCIC160BVC SCIC0BVC SCICBVC SCIC063DVC SCIC075DVC 65 1 1 1 0 65 63 75 90 1 1 160 0 63 75 SCIC090DVC SCICDVC SCIC1DVC SCIC1DVC SCIC160DVC SCIC0DVC SCICDVC SMICIVC SMICIVC SMIC315IVC 1 1 1 0 90 1 1 160 0 315 39,88 1,54 8,19 17,73 19,55,58 13,10 38,18 10,11 49,44 5,4 6,05 4.01,98,57 16,67,03 160, 39,88 1,54 8,19 17,73 19,55 13,10 10,11 5,4 4.01,57,03 1,64 1,31 1,03 19,55 38,18 49,44 6,05,98 16,67 160, 198,46 48,60 315,19 BS Solvent Weling PVC Tee Fittings for BS PN1 pipes (female ens for solvent weling) TFLVB 15 1/" 46,04 TFLVB 3/4" 7,89 TFLVB 1" 157,86 TFLVB 1 1/4" 101,60 TFLVB 1 1/" 63,7 TFLVD 15 1/" 46,04 TFLVD 3/4" 7,89 TFLVD 1" 157,86 TFLVD 1 1/4" 101,60 TFLVD 1 1/" 63,7 15
NPT Female Threae PVC Tee Fittings for ASTM SCH. pipes (NPT threae female ens) TFNVB TFNVB TFNVB TFNVB TFNVB TFNVD TFNVD TFNVD TFNVD TFNVD SIZE 0." 0.75" 1.00" 1." 1." 0." 0.75" 1.00" 1." 1." R 1/" 3/4" 1" 1 1/4" 1 1/" 1/" 3/4" 1" 1 1/4" 1 1/" 46,04 7,89 157,86 101,60 63,7 46,04 7,89 157,86 101,60 63,7 ASTM SCH. PVC Tee Fittings for ASTM SCH. pipes (female ens for solvent weling) TFAVB TFAVB TFAVB TFAVB TFAVB TFAVD TFAVD TFAVD TFAVD TFAVD BS Clamp Sales for BS PN1 pipes SCLC.0BVM SCLC3.0BVM SCLC4.0BVM SCLC6.0BVM SCLC8.0BVM SCLC.0DVM SCLC3.0DVM SCLC4.0DVM SCLC6.0DVM SCLC8.0DVM 1 0 1 0 " 3" 4" 6" 8" " 3" 4" 6" 8" 43,,04 1,17 3,64,10 43,,04 1,17 3,64,10 SIZE 0." 0.75" 1.00" 1." 1." 0." 0.75" 1.00" 1." 1." 0,85" 1,06" 1,33" 1,67" 1,91" 0,85" 1,06" 1,33" 1,67" 1,91" 46,04 7,89 157,86 101,60 63,7 46,04 7,89 157,86 101,60 63,7 ASTM SCH. Clamp Sales for ASTM SCH. pipes SIZE SCAC.0BVM.00",375" 53,93 9,7 SCAC.5BVM.",875" 37,67 13,7 SCAC3.0BVM 3.00" 3,0" 4,06,78 SCAC4.0BVM 4.00" 4,0" 17,84 8,03 SCAC5.0BVM 5.00" 5,5" 13,77 36,31 SCAC6.0BVM 6.00" 6,6" 3,93 8,57 SCAC8.0BVM 8.00" 8,6",4 145,00 SCAC.0DVM.00",375" 53,93 9,7 SCAC.5DVM.",875" 37,67 13,7 SCAC3.0DVM 3.00" 3,0" 4,06,78 SCAC4.0DVM 4.00" 4,0" 17,84 8,03 11,49 4,95 41,10 89,19 154,74 11,49 4,95 41,10 89,19 154,74 16 SCAC5.0DVM 5.00" 5,5" 13,77 36,31 SCAC6.0DVM 6.00" 6,6" 3,93 8,57 SCAC8.0DVM 8.00" 8,6",4 145,00
Installation on C-PVC pipes ISO Metric CPVC Tee Fitings for ISO SDR 1 pipes (female ens for solvent weling) TFICB 15 46,04 TFICB 7,89 TFICB 157,86 TFICB TFICB TFICD TFICD TFICD TFICD TFICD 15 CPVC Glue-on Fittings WAIC063 63 WAIC075 65 75 WAIC090 90 WAIC WAIC1 1 WAIC1 1 1 WAIC160 1 160 WAIC0 1 0 WAIC 0 WAIC WAIC WAIC315 315 101,60 63,7 46,04 7,89 157,86 101,60 63,7 ISO Clamp Sales for ISO SDR 1 pipes SCIC063BVC SCIC075BVC 65 SCIC090BVC SCICBVC 63 75 90 39,88 8,19 19,55 13,10 1,54 17,73,58 38,18 SCIC1BVC SCIC1BVC SCIC160BVC SCIC0BVC SCICBVC SCIC063DVC SCIC075DVC SCIC090DVC 1 1 1 0 65 1 1 160 0 63 75 90 10,11 5,4 4,01,57,03 39,88 8,19 19,55 49,44 6,05,98 16,67 160, 1,54 17,73,58 SCICDVC SCIC1DVC SCIC1DVC SCIC160DVC SCIC0DVC SCICDVC SMICIVC SMICIVC SMIC315IVC 1 1 1 0 1 1 160 0 315 13,10 10,11 5,4 4,01,57,03 1,64 1,30 1,03 38,18 49,44 6,05,98 16,67 160, 198,46 48,60 315,19 Installation on PP pipes ISO Metric PP Tee Fittings for ISO SDR 11 pipes (female ens for socket weling) TFIMB 15 510,01 TFIMB 1,51 TFIMB 19,77 TFIMB 14,34 TFIMB 79,18 TFIMD 15 510,01 TFIMD 1,51 TFIMD 19,77 TFIMD 14,34 TFIMD 79,18 BSP Female Threae PP Tee Fittings for BS pipes (parallel threae female ens) R TFFMB 15 1/" 510,01 TFFMB 3/4" 1,51 TFFMB 1" 19,77 TFFMB 1 1/4" 14,34 TFFMB 1 1/" 79,18 TFFMD 15 1/" 510,01 TFFMD 3/4" 1,51 TFFMD 1" 19,77 TFFMD 1 1/4" 14,34 TFFMD 1 1/" 79,18 17
ISO Clamp Sales for ISO SDR 1 pipes SCIC063BME SCIC075BME SCIC090BME SCICBME SCIC1BME SCIC1BME SCIC160BME SCIC0BME SCICBME SCIC063DME SCIC075DME SCIC090DME SCICDME 65 1 1 1 0 65 63 75 90 1 1 160 0 63 75 90 4, 9,86,71 13,84 10,68 5, 4,3,71,14 4, 9,86,71 13,84 11,79 16,75 4,14 36,1 46,83 59,1 76,75 119,99 151,79 11,79 16,75 4,14 36,1 SCIC1DME SCIC1DME SCIC160DME SCIC0DME SCICDME SMICIME SMICIME SMIC315IME 1 1 1 0 1 1 160 0 315 10,68 5, 4,3,71,14 1,73 1,38 1,09 46,83 59,1 76,75 119,99 151,79 187,83 35,53 98,07 PP Glue-on Fittings WAIM063 63 WAIM075 65 75 WAIM090 90 WAIM WAIM1 1 WAIM1 1 1 WAIM160 1 160 WAIM0 1 0 WAIM 0 WAIM WAIM WAIM315 315 NPT Female Threae PP Tee Fittings for ASTM SCH. pipes (NPT threae female ens) TFNMB TFNMB TFNMB TFNMB TFNMB TFNMD TFNMD TFNMD TFNMD TFNMD 18 0." 0.75" 1.00" 1." 1." 0." 0.75" 1.00" 1." 1." R 1/" 3/4" 1" 1 1/4" 1 1/" 1/" 3/4" 1" 1 1/4" 1 1/" 510,01 1,51 19,77 14,34 79,18 510,01 1,51 19,77 14,34 79,18 ASTM SCH. Clamp Sales for ASTM SCH. pipes SIZE SCAC.0BME.00",375" 53,93 SCAC.5BME.",875" 37,67 SCAC3.0BME 3.00" 3,0" 4,06 SCAC4.0BME 4.00" 4,0" 13,77 SCAC5.0BME 5.00" 5,5" 8,68 SCAC6.0BME 6.00" 6,6" 6,06 SCAC8.0BME 8.00" 8,6" 3,45 9,7 13,7,78 36,31 57,57 8,57 145,00 SCAC.0DME.00" SCAC.5DME." SCAC3.0DME 3.00" SCAC4.0DME 4.00" SCAC5.0DME 5.00" SCAC6.0DME 6.00" SCAC8.0DME 8.00" 9,7 13,7,78 36,31 57,57 8,57 145,00,375",875" 3,0" 4,0" 5,5" 6,6" 8,6" 53,93 37,67 4,06 13,77 5,64 3,99,4
Installation on PVDF pipes ISO Metric PVDF Tee Fittings for ISO SDR 33 pipes (female ens for socket weling) TFIFB 15 510,01 TFIFB 94,9 TFIFB 178,60 TFIFB 105,74 TFIFB 67,60 TFIFD 15 510,01 TFIFD 94,9 TFIFD 178,60 TFIFD 105,74 TFIFD 67,60 ISO Clamp Sales for ISO SDR 33 pipes SCIC063BF 63 37, 13,44 SCIC075BF 65 75 6,06 19,19 SCIC090BF 90 18,09 7,64 SCICBF 1,09 41,34 SCIC1BF 1 9,38 53,30 SCIC1BF 1 1 4,84 67,08 SCIC160BF 1 160 3,70 87,77 SCIC0BF 1 0,37 136,89 SCICBF 0 1,87 173,68 SCIC063DF 63 37, 13,44 SCIC075DF 65 75 6,06 19,19 SCIC090DF 90 18,09 7,64 SCICDF 1,09 41,34 SCIC1DF 1 9,38 53,30 SCIC1DF 1 1 4,84 67,08 SCIC160DF 1 160 3,70 87,77 SCIC0DF 1 0,37 136,89 SCICDF 0 1,87 173,68 Installation on PE pipes ISO Metric PVC Tee Fittings for PE SDR 11 pipes ISO Clamp Sales for PE SDR 11 pipes SCIC063BME 63 49,53 SCIC075BME 65 75 34,67 SCIC090BME 90 3, SCICBME 16,07 SCIC1BME 1 1,48 SCIC1BME 1 1 6,41 SCIC160BME 1 160 4,95 SCIC0BME 1 0 3,17 SCICBME 0, SCIC063DME 63 49,53 SCIC075DME 65 75 34,67 SCIC090DME 90 3, SCICDME 16,07 SCIC1DME 1 1,48 SCIC1DME 1 1 6,41 SCIC160DME 1 160 4,95 SCIC0DME 1 0 3,17 SCICDME 0, SMICIVC,01 SMICIVC 1,61 SMIC315IVC 315 1,7 (PE en connectors for electrofusion or butt weling) TFIVBE 15 510,01 TFIVBE 318,30 TFIVBE 194,7 TFIVBE 1, TFIVBE 78,79 TFIVDE 15 510,01 TFIVDE 318,30 TFIVDE 194,7 TFIVDE 1, TFIVDE 78,79 PE Glue-on Fittings WAIE063 WAIE075 65 WAIE090 WAIE WAIE1 WAIE1 1 WAIE160 1 WAIE0 1 WAIE 0 WAIE WAIE WAIE315 63 75 90 1 1 160 0 315 19 10,09 14,4 1,7 31,11,06,68 65,55 10,55 19, 10,09 14,4 1,7 16,07,06,68 65,55 10,55 19, 161,83 1,9 4,96
Special Installation on an 300 pipes PVC Wafer Fittings WVICB WVIC315B 300 WVICD WVIC315D 300 315 315 PP Wafer Fittings WFICB WFIC315B 300 WFICD WFIC315D 300 315 315 Metal Fittings 316L SS Threae Tees (BSP Female Threas) R TFFX 3/4" TFFX 1" TFFX 1 1/4" 308,1 177,84 88,85 Metal Strap-on Sales mounte on Other Metal pipes 19,0 SZIC0I 11,8 SZICI 4,83 SZIC1I 1 3,31 SZIC1I 1 1,95 SZIC0I 0 1,4 SZICI SZIC300I 300 0,73 SZIC3I 3 0,54 SZIC0I 0 --------SZIC4I 4 Metal Strap-on Sales mounte on Cast Iron pipes SZIC0I SZICI SZIC1I SZIC1I SZIC0I SZICI SZIC300I SZIC3I SZIC0I SZIC4I 1 1 0 300 3 0 4, 1,99 5,31 3,67,03 1,31 0,90 0,67 0,53 0, 316L SS Wel-on Aapters mounte on Cast Iron pipes -------- -------- 37,3 60 -------- 65, 1,99 -------- 5,31 1 3,67 1 -------- 175,03 0 -------- 1,31 0,90 300 0,68 3 0,53 0 0, 4 0,34 0 600 0,3 4,7 38, 61, 88,55 160, 48,60 36,76 4,66 6, 1,10 6,9 44, 67,30 98,13 166,9 61,85 369,74 447,1 600,8 ----------- 316L SS Wel-on Aapters mounte on Other Metal pipes ----------------13,43 --------4,7 38, --------61, 88,55 --------160, --------48,60 36,84 4,77 6,35 1,8 961,54 1373,63 60 65 1 1 175 0 300 3 0 4 0 53,74 43,60 --------6, 19,0 11,8 --------4,83 3,31 --------1,95 --------1,4 0,73 0,54 --------0,34 9,30 11,47 --------19,07 6,9 44, --------67,30 98,13 --------166,9 --------61,85 369,8 447,3 600,96 --------961,54 600 --------- ---------
Correction formula for calculation accoring to real internal iameter: _NEW = ( x ID²) / ID_NEW² where: ID = Value in the table for the internal iameter (in mm) ID_NEW = New value for the real internal iameter (always in mm) = Value in the table _NEW = New value for the specifie internal iameter EXAMPLE: Nominal Pipe Size () = mm New Internal Diameter = 104 mm Using the formula: _NEW = (51.0 x ²) / 104² =,5 Correction formula for calculation accoring to the new full scale : ( New Full Scale ) = (5 m/sec / New Full Scale ) * where: New Full Scale = New Full Scale set by USB interface = Value in the table ( Stanar to 5 m/sec ) (NEW Full Scale ) = New value for the New Full Scale EXAMPLE: Full Scale Stanar = 5 m/sec New Full Scale = 8 m/sec K-factor for Pipe OD an PVC material = 13.10 ( New Full Scale ) = ( 5 m/sec / 8 m/sec ) * 13.10 = 8.19 1
8. Orering Data FLOWX3 NEW F3.60M.XX.S Power supply Length Boy Electroes O-rings Enclosure F3.60M.09.S 4 VDC L0 316L SS/PVDF 316L SS EPDM IP65 F3.60M.10.S 4 VDC L0 316L SS/PVDF 316L SS FPM IP65 F3.60M.11.S 4 VDC L1 316L SS/PVDF 316L SS EPDM IP65 F3.60M.1.S 4 VDC L1 316L SS/PVDF 316L SS FPM IP65 F3.60M.33.S 4 VDC L0 CuNi/PVDF CuNi EPDM IP65 F3.60M.34.S 4 VDC L0 CuNi /PVDF CuNi FPM IP65 F3.60M.35.S 4 VDC L1 CuNi /PVDF CuNi EPDM IP65 F3.60M.36.S 4 VDC L1 CuNi /PVDF CuNi FPM IP65 F3.60M.38.S 4 VDC L0 316L SS/PEEK 316L SS FPM IP65 F3.60M..S 4 VDC L1 316L SS/PEEK 316L SS FPM IP65 Spare Parts Mechanical Replacements Item 1 3 3 Name Description F3.KC1 Magmeter Compact mounting Kit Plastic aapter with gasket, compact cap, locking ring an 4 fixing screws F9.SP4.1 PG 13.5 PG 13.5 Cable Glan for Compact Kit F9.SP4. PG 11 PG 11 Cable Glan for Compact Kit F3.SP3.1 O-Rings EPDM Sensor boy O-rings F3.SP3. O-Rings FPM Sensor boy O-rings
Electronic Replacements Item 1 Name Description F3.60M.SP1.S Electronic evice F3.60M.SP09 Magmeter flow sensor F3.60M.SP10 Magmeter flow sensor F3.60M.SP11 Magmeter flow sensor F3.60M.SP1 Magmeter flow sensor F3.60M.SP13 Magmeter flow sensor F3.60M.SP14 Magmeter flow sensor F3.60M.SP15 Magmeter flow sensor F3.60M.SP16 Magmeter flow sensor F3.60M.SP17 Magmeter flow sensor F3.60M.SP18 Magmeter flow sensor 3 Magmeter electronic evice with 4mA output an freq. output, 316L SS/PVDF boy EPDM O-Rings L0 length 316L SS/PVDF boy FPM O-Rings L0 length 316L SS/PVDF boy EPDM O-Rings L1 length 316L SS/PVDF boy FPM O-Rings L1 length CuNi/PVDF boy EPDM O-Rings L0 length CuNi/PVDF boy FPM O-Rings L0 length CuNi/PVDF boy EPDM O-Rings L1 length CuNi/PVDF boy FPM O-Rings L1 length 316L SS/PEEK boy FPM O-Rings L0 length 316L SS/PEEK boy FPM O-Rings L1 length
F.I.P. Formatura Iniezione Polimeri S.p.A. Loc. Pian i Parata, 16015 Casella (GE) Italy Tel +39 010 9611 Fax +39 010 9619 www.flsnet.it 4