Ceiling Concealed Chilled Water Fan Coil Unit

Similar documents
DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

Ceiling Concealed Chilled Water Fan Coil Unit

Amendment Sheet. Code : ADB-FR Date : Superceded : nil REFRIGERANT CIRCUIT DIAGRAM

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

Technical Sales Guide # 040 YDFC 0 1 Page 2

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

42HS Fan Coil Unit (High Static Pressure)

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

CEW SERIES CEILING EXPOSED HORIZONTAL FAN COIL UNITS

Address: VTS Clima L.L.C.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

Contents. Carrier China

High Static Pressure Duct Fan Coil Unit

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

McQuay MDM Air Handling Unit CMDM

High Static Fan Coil Units YDFC

CENTRIFUGAL FAN COIL UNIT VCE

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Low Static Pressure Duct(V shape evaporator)

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

Midea Air Handling Unit

VHIA High-Static Ducted Indoor Units - 60HZ

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Concealed Ducted Split Series R22

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

(Thin) (Ultrathin) Suspended Air-handling Unit

Cassette 4 Ways FCU DC Service manual

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

Chilled Water Vertical Fan Coils

The World Leading Air-conditioning Company

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

Commercial Blower Coil Air Handlers

Low Static Pressure Duct (V shape evaporator)

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

CBH17-95V Horizontal Unit CB V

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

PHCD-Series. Catalog

R-22, 13 SEER 60 Hertz

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

Aesthetically Attractive Indoor unit. Enhanced with various Indoor Air Quality Features. Negative Ion Generator (Standard)

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

CHP

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Refrigeration copper tube aluminum fin evaporator

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

CHP20R Basic Unit CHP

BAC / BHC Product Specifications

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

CHILLED WATER DUCTED FAN COIL

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

ZHA/ZHB SERIES WARNING

FCX TECHNICAL BOOKLET

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

BRIZA 22 HYBRID HEATING & COOLING

SECTION AIR TERMINAL UNITS

ELITE SERIES R-410A Ready - Multi-Position

Engineering Data Book

Submittal. Holder Construction Company. Reviewed. Reviewed as Noted. Rejected. 1. Updates per Bulletin #4

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

IDENTIFICATION ACCESSORIES DESCRIPTION

CHILLED WATER FAN-COIL UNITS

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

FCVC Series VERTICAL FAN COILS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001

#7 Stock Cabinet Fan/Coils

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

FN Fan-Coil Units High-Performance, Horizontal

Transcription:

Engineer Data ED-FWW-V-01401 Ceiling Concealed Chilled Water Fan Coil Unit Models: FWW00 FWW300 FWW400 FWW500 FWW600 FWW700 FWW800 FWW1000 FWW100 FWW1400 ir Flow: 340-380m 3 /h

Literature No.: ED-FWW-V-01401 Supersedes: ED-FWW-V-01310 Contents Nomenclature Valve Nomenclature 3 Features 4 Specifications 5 Sound Data 6 ir Flow vs ESP Curve 7 Operating Limits 8 Water Flow Rate/Pressure Drop Chart 9 Outlines and Dimensions 10 Electrical Data 11 Wiring Diagrams 1 Installation 13 NOTE: Installation and maintenance are to be performed only by qualified personnel who are familiar with local codes and regulations, and experienced with this type of equipment. Caution: Sharp edges and coil surfaces are a potential injury hazard. void contact with them. Warning: Moving machinery and electrical power hazard. May cause severe personal injury or death. Disconnect and lock off power before servicing equipment. 1

Nomenclature FWW 00 V C 3 R C X - 0 E Sales Region: Power Supply: Other Feature Codes Material of Drain Pan E: Export : 0V~/50 Hz Filter: X: no filter F: 8mm nylon filter : 8 mm aluminum filter Return ir Plenum: Pipe Connection: External Static Pressure: 1: 1 Pa 3: 30 Pa 5: 50 Pa Coil Type: Unit Design SN C: without return air plenum B: back return air plenum D: bottom return air plenum R: facing air flow right hand L: facing air flow left hand C: 3 rows Rated ir Volume (CFM, 1 CFM = 1.7 m 3 /h) DIKIN Ceiling Concealed Horizontal Fan Coil Unit

Valve Nomenclature FWW - V 4 Y B R E E-Export U-Stick "Made In China" Power Supply: -0-40V/1Ph/50Hz K-08-30V/1Ph/60Hz Pipe Connection R-for Right hand unit L-for Left hand unit Valve Type B-with Ball Valve X-without Ball Valve Strainer Type Y-with Y-Strainer X-without Y-Strainer Union Size Omitted-R3/4 4-R1 Valve model V:-Way Valve Kit 3V:3-Way Valve Kit FWW-DIKIN FCU (Only -pipe system is applicable) 3

Features Compact Light-weighted, good-looking appearance, and compact and solid structure. 35 mm height, allowing installation on the ceiling with a limited space. Low-noise Low-noise motor for driving the low speed fan with a wide impeller; strictly tested before delivery. Precise distance between the impeller inlet/outlet and the heat exchanger for more reasonable air flow distribution. Highly efficient sound-absorbing and heat-preserving materials inside to minimize noises produced by the unit. Reliable Single-phase capacitor motor with the protection grade IP0 and insulation grade B to ensure operation safety. Permanently lubricated and sealed ball bearing with high precision, which is provided by internationally famous brands and receives processing including hardening and tempering as well as chroming. Motor power outlet wires protected by metal hoses to ensure its durability. Working pressure up to 1.6 MPa and test pressure up to.0 MPa for the heat exchanger to endure high pressures and prevent leakage. High Efficiency Heat exchanger with the high-quality mechanically expanded copper pipe and hydrophilic aluminum fins to ensure high efficiency. Intensified air supply using a large air flow fan with a wide impeller to maximize the heat transfer performance. Precise matching of the fan and motor to guarantee the maximum cooling capacity but a low power input. Flexible Multiple external static pressures designed based on the unit s cooling capacity, meeting the air supply requirements at different distances. Optional bottom return air plenum or back return air plenum with support for onsite changes, featuring time saving. Variable accessories for more options. nti-leakage Delicate condensate-proof drain pan made of the cold-rolled steel through one-time impact molding, with coating on both sides and high-quality heat-preserving materials on the exterior. Unique independent mounting bracket without soldering seams or joints, requiring no bolts for fixing to prevent damages to the drain pan heat-preserving layer or cold bridges. Tilt structure for rapid condensate water drainage. 4

Specifications General Data MODEL HIGH FWW-VC FWW00VC FWW300VC FWW400VC FWW500VC FWW600VC FWW700VC FWW800VC FWW1000VCFWW100VCFWW1400VC m 3 /h 340 510 680 850 100 1170 1360 1700 040 380 CFM 00 300 400 500 600 688 800 1000 100 1400 ir Flow MEDIUM LOW m 3 /h 79 418 558 697 836 564 1115 1394 1673 195 CFM 164 46 38 410 49 33 656 80 984 1148 m 3 /h 170 55 340 45 510 8 680 850 100 1190 CFM 100 150 00 50 300 166 400 500 600 700 EXTERNL Pa/in.wg 1,30,50/0.05,0.1,0.0 STTIC PRESSURE TOTL COOLING CPCITY SENSIBLE COOLING CPCITY TOTL HETING CPCITY WTER FLOW RTE HED LOSS (Cooling) UNIT WEIGHT (Without plenum) UNIT GROSS WEIGHT (Without plenum) DIMENSIONS Without Return ir Plenum With Back Return ir Plenum With Bottom Return ir Plenum UNIT WEIGHT (With plenum) UNIT GROSS WEIGHT (With plenum) CONDENSTE DRIN SIZE W 0 3300 460 5050 580 6600 800 9300 11190 13000 Btu/h 7575 1160 14536 1731 19859 50 7980 31733 3818 44358 W 1380 0 770 3400 4000 4550 5500 6500 7700 900 Btu/h 4709 7575 945 11601 13649 1555 18767 179 673 3139 W 3500 5330 6800 8400 9600 11100 13500 15800 18300 1500 Btu/h 1194 18187 303 866 3757 37875 46064 5391 644 73361 m 3 /h 0.37 0.58 0.7 0.88 1.0 1.14 1.41 1.67 1.95.9 USGPM 1.6.6 3. 3.9 4.5 5.0 6. 7.4 8.6 10.1 Pa 5 1 33 3 3 35 3 40 40 47 in.wg. 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0. 0. 0. kg 10.3 1.4 1.8 15.1 16.7 17.6 5. 8.6 31.0 33.5 lb.7 7.3 8. 33.3 36.8 38.8 55.6 63.1 68.3 73.9 kg 1.4 14.7 15.3 17.8 19.4 0.4 8.9 3.4 35.4 38.5 lb 7.3 3.4 33.7 39. 4.8 45.0 63.7 71.4 78.0 84.9 mm 65 465 35 815 465 35 865 465 35 945 465 35 1045 465 35 1095 465 35 145 465 35 1475 465 35 1675 465 35 185 465 35 mm 65 516 35 815 516 35 865 516 35 945 516 35 1045 516 35 1095 516 35 145 516 35 1475 516 35 1675 516 35 185 516 35 mm 65 497 35 815 497 35 865 497 35 945 497 35 1045 497 35 1095 497 35 145 497 35 1475 497 35 1675 497 35 185 497 35 kg 13. 16.0 16.7 19.3 1..4 31.3 34.8 38.0 41.5 lb 9.1 35.3 36.8 4.5 46.7 49.4 69.0 76.7 83.8 91.5 kg 15.3 18.3 19..0 3.9 5. 35.0 38.6 4.4 46.5 lb 33.7 40.3 4.3 48.5 5.7 55.6 77. 85.1 93.5 10.5 R3/4 NOTES: 1) LL SPECIFICTIONS RE SUBJECTED TO CHNGE BY THE MNUFCTURER WITHOUT PRIOR NOTICE. ) LL THE UNITS RE BEING TESTED UNDER FOLLOWING CONTITION: COOLING-7 C DB/19.5 C WB INDOOR ND WTER INLET 7 C OUTLET 1 C HETING-1 C DB INDOOR ND WTER 60 C INLET.WTER FLOW:WME WITH COOLING CONDITION. 3) SOUND PRESSURE LEVEL RE CCORDING TO MICROPHONE POSITION OF THE MESUREMENT POINT IS 1m IN FRONT ND 5

Components Data FN MOTOR COIL IR FILTER (Option) TYPE FWW-VC FWW00VC FWW300VC FWW400VC FWW500VC FWW600VC FWW700VC FWW800VC FWW1000VC FWW100VC FWW1400VC GLVNIZED STEEL DOUBLE STGE IMPELLER CENTRIFUGL (BLDE: FORWRD) QUNTITY 1 3 3 4 4 MTERIL DRIVE DIMETER LENGTH TYPE GLVNIZED STEEL DIRECT DRIVE mm 150 in 5.904 mm 150/00/40 in 5.91/7.87/9.45 SINGLE PHZE BLL BERING CPCITOR RUNNING QUNTITY 1 1 1 1 1 1 IP/INSULTION GRDE TUBE FIN TYPE SIZE MTERIL IP0/B COPPER mm 7 DIMETER in 0.8 mm 0.5 THICKNESS in 0.01 MTERIL HYDROPHILIC LUMINUM mm 0.11 THICKNESS in 0.0043 FCE RE m 0.08 0.1 0.13 0.15 0.17 0.18 0.5 0.6 0.30 0.34 ft 0.86 1.9 1.40 1.61 1.83 1.94.69.80 3.3 3.66 ROW 3 FIN PER INCH 17 LENGTH WIDTH NYLON/LUMINIUM FRME mm 438 68 678 758 858 908 138 188 1488 1638 in 17.4 4.7 6.69 9.83 33.77 35.74 48.73 50.70 58.57 64.47 mm 196 in 7.71 THICKNESS mm 8 in 0.31 NOTES: LL SPECIFICTIONS RE SUBJECTED TO CHNGE BY THE MNUFCTURER WITHOUT PRIOR NOTICE. Sound Data Model Sound Pressure Level (ESP: 1Pa) Sound Pressure Level (ESP: 30 Pa) Sound Pressure Level (ESP: 50 Pa) FWW-VC FWW00VC FWW300VC FWW400VC FWW500VC FWW600VC FWW700VC FWW800VC FWW1000VC FWW100VC FWW1400VC High db 33.9 33. 40.0 40.3 44.4 45. 43.9 47.9 48.0 51.0 Middle db 9.3 8.8 35.5 36.3 39 40.3 38.6 43.6 44.3 47.5 Low db 0.1 4. 4.0 5.6 9.8 7.9 7.4 3.6 33.4 38.0 High db 37.3 37.6 41.6 44.3 46.5 46.6 46. 49.3 50.9 5.0 Middle db 3.5 3.5 36.5 39.5 41.1 41.8 41.3 44.9 45.7 46.0 Low db 0.9.8 5.8 7.3 7.3 9.4 30.6 36.4 34.7 35.5 High db 41. 4. 44.4 46.4 47.5 47.5 48.3 50.6 51.8 53.5 Middle db 37.3 35.8 40.5 4.7 43.9 43.6 43.7 46.4 47.1 49.0 Low db 6.1 5.8 3.3 31.3 33.9 37.3 31.8 37.6 41.7 41.0 NOTES: 1) LL SPECIFICTIONS RE SUBJECTED TO CHNGE BY THE MNUFCTURER WITHOUT PRIOR NOTICE. ) SOUND PRESSURE LEVEL RE CCORDING TO MICROPHONE POSITION OF THE MESUREMENT POINT IS 1m IN FRONT ND 1m BELOW THE UNIT. 6

ir Flow vs ESP Curve ESP, 1Pa ir Flow, m 3 /h FWW100 FWW1000 FWW800 FWW700 FWW600 FWW500 FWW400 FWW300 FWW00 ESP, Pa ESP, 30Pa ir Flow, m 3 /h FWW100 FWW1000 FWW800 FWW700 FWW600 FWW500 FWW400 FWW300 FWW00 ESP, Pa ESP, 50Pa ir Flow, m 3 /h FWW100 FWW1000 FWW800 FWW700 FWW600 FWW500 FWW400 FWW300 FWW00 ESP, Pa 7

Operating Limits Operating Limits Water Circuit Max. Water side pressure Min. Entering water temperature Power supply Operating voltage limits Operating frequency limits 1.6MPa 3ºC (cooling) ±10% Volt ±Hz FWW-V 8

Water Flow Rate/Pressure Drop Chart FWW-VC WTER PRESSURE DROP CURVE(3 Rows) 65 WTER PRESSURE DROP kpa 60 55 50 45 40 35 30 5 0 15 10 FWW700VC FWW500VC FWW300VC FWW400VC FWW00VC FWW600VC FWW100VC FWW800VC FWW1000VC 5 0 0.1 0. 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1. 1.3 1.4 1.5 1.6 1.7 1.8 1.9.1..3 WTER FLOW m 3 /h 9

8 75 0 Outlines and Dimensions WITHOUT PLENUM 187 44 D B C 40 MOUNTING HOLE 4-10 16 CONDENSTE DRIN R3/4 IR VENT 30 143 6 35 35 151 14 WTER SUPPLY CONNECTION Rc3/4 WTER RETURN CONNECTION Rc3/4 105 0 131 4 6 465 Model Number B C Number Model Standard Standard Long Long B C D Of Fans Drain Pan Drain Pan Of Fans Drain Pan Drain Pan MCW00V 65 75 40 437 440 1 FWW00V 65 75 40 437 440 1 MCW300V 815 915 59 67 630 FWW300V 815 915 59 67 630 MCW400V 865 965 64 677 680 FWW400V 865 965 64 677 680 MCW500V 945 1045 7 757 760 FWW500V 945 1045 7 757 760 MCW600V 1045 1145 8 FWW600V 1045 1145 MCW700V 1095 1195 FWW700V 1095 1195 87 857 8 857 87 907 907 860 860 910 910 FWW800V MCW800V 145 145 155 155 10 10 137 FWW1000V MCW1000V 1475 1475 1575 1575 15 15 187 FWW100V MCW100V 1675 1675 1775 1775 145 145 1487 140 190 1490 3 33 44 FWW1400V MCW1400V 185 185 195 195 160 160 1637 1640 44 WITH BCK PLENUM 146 187 44 E F B C 40 TERMINL BOX MOUNTING HOLE 4-10 16 CONDENSTE DRIN R3/4 IR VENT 30 143 6 35 WTER SUPPLY CONNECTION Rc3/4 WTER RETURN CONNECTION Rc3/4 35 151 131 4 6 516 180 3 Number Of Model Standard Drain Long Drain B C D E Fans Number Model Standard Long B C D E F Pan Pan Of Fans Drain Pan Drain Pan MCW00V 65 75 40 437 440 47 40 1 FWW00V 65 75 40 437 440 47 40 1 MCW300V 815 915 59 67 630 66 610 FWW300V 815 915 59 67 630 66 610 MCW400V 865 965 64 677 680 71 660 FWW400V 865 965 64 677 680 71 660 MCW500V 945 1045 7 757 760 79 740 FWW500V 945 1045 7 757 760 79 740 MCW600V 1045 FWW600V 1045 FWW700V MCW700V 1095 1095 1145 8 857 860 89 1145 8 857 860 89 1195 1195 87 87 907 907 910 910 94 94 840 840 890 890 FWW800V MCW800V 145 145 FWW1000V MCW1000V 1475 1475 FWW100V MCW100V 1675 1675 155 155 10 10137 137 140 17 10 1575 1575 15 15187 187 190 13 170 1775 1775 145 1451487 1487 1490 15 1470 3 3 4 FWW1400V MCW1400V 185 185 195 195 160 1601637 1637 1640 167 160 4 WITH BOTTOM PLENUM 146 187 44 38 E B C Number Of Model B C G Model Standard Drain Long Drain Fans Standard Long B C D E G Number Pan Pan Of Fans 40 Drain Pan Drain Pan MCW00V 65 75 40 437 440 47 441 1 TERMINL BOX FWW00V 65 75 40 437 440 47 441 1 MCW300V 815 915 59 67 630 66 581 MOUNTING HOLE 4-10 16 FWW300V 815 915 59 67 630 66 581 MCW400V 865 965 64 677 680 71 681 CONDENSTE DRIN FWW400V 865 965 64 677 680 71 681 MCW500V 945 1045 7 757 760 79 761 R3/4 FWW500V 945 1045 7 757 760 79 761 IR VENT MCW600V 1045 1145 8 857 860 89 861 FWW600V 1045 1145 8 857 860 89 861 FWW700V MCW700V 1095 1095 1195 1195 87 87 907 907 910 94 911 911 497 WTER SUPPLY 105 FWW800V MCW800V 145 145 155 155 10 137 140 17 141 141 3 CONNECTION FWW1000V MCW1000V 1475 1575 15 187 190 13 191 191 3 Rc3/4 WTER RETURN FWW100V MCW100V 1675 1775 145 1487 1490 15 1491 4 CONNECTION Rc3/4 FWW1400V MCW1400V 185 195 160 1637 1640 167 1641 4 30 143 6 35 35 151 131 4 6 3 17 (175) 16 G 10

Electrical Data FWW-VC MODEL INSULTION GRDE POWER SOURCE RTED INPUT 1Pa POWER MOTOR RTED RUNNING CURRENT POLES INSULTION GRDE POWER SOURCE RTED INPUT 30Pa POWER MOTOR RTED RUNNING CURRENT POLES INSULTION GRDE POWER SOURCE RTED INPUT 50Pa POWER MOTOR RTED RUNNING CURRENT POLES FWW00VC FWW300VC FWW400VC FWW500VC FWW600VC FWW700VC FWW800VC FWW1000VC FWW100VC FWW1400VC V/Ph/Hz 0~/1/50 W 3 43 56 73 93 113 133 15 188 8 0.15 0.0 0.6 0.34 0.43 0.5 0.61 0.70 0.86 1.1 V/Ph/Hz 0~/1/50 W 39 53 7 83 107 1 14 174 17 50 0.18 0.4 0.33 0.38 0.49 0.56 0.65 0.80 1.00 1.19 V/Ph/Hz 0~/1/50 W 46 6 80 95 11 131 168 00 37 90 0.1 0.8 0.37 0.44 0.51 0.60 0.77 0.9 1.09 1.45 B 4P B 4P B 4P NOTES: 1) LL SPECIFICTIONS RE SUBJECTED TO CHNGE BY THE MNUFCTURER WITHOUT PRIOR NOTICE. ) LL ELECTRIC DT RE BEING TESTED UNDER HIGH SPEED. 11

Wiring Diagrams Molde: FWW 800-1400 H M L FN SPEED SWITCH HF MF LF YELLOW BROWN ORNGE FN MOTOR 1 BLUE BLCK BLCK MOTOR CPCITOR L (0V~ /50Hz) N YELLOW BLUE BLCK BROWN ORNGE FN MOTOR BLCK MOTOR CPCITOR NOTE: HF: FN SPEED HIGH MF: FN SPEED MEDIUM LF: FN SPEED LOW FIELD WIRING Only unit 800~100 have fan motor 1

Installation Receiving ll units leaving the DIKIN plant have been inspected to ensure the shipment of high quality products and reasonable means are utilized to properly pack the fan coil units to protect them in transit. Carefully inspect all shipments immediately upon delivery. When damage is visible, note this fact on the carrier s freight bill and request that the carrier sends a representative to inspect the damage. This may be done by telephone or in person, but should always be confirmed in writing. The shipment should be unpacked in the presence of the agent so that the damage or loss can be determined. The carrier s agent will make an inspection report and a copy will be given to the consignee for forwarding to the carrier with a formal claim. Location Before installation, please check the following: There must be enough space for unit installation and maintenance. Please refer to the unit s drawings and dimensions and fig.1 for the minimum distance between the unit and obstacle. Please ensure enough space for piping connection and electrical wiring. Please make sure that the hanging rods can support weight of the unit. Installation The unit is designed for concealed ceiling installation. There are holes on the top of the unit for hanging. Please refer to Fig.1.Fig. and Fig.3. Make sure that the top of the unit is level. Insulation 1) Use proper insulation material only ) Chilled water pipes and all parts on the pipes should be insulated 3) It is also necessary to insulated air ducted 4) dhesive for insulation should work under range 0 F(-18 C) to 00 F(93.3 C). Fig.1 OBSTCLE OBSTCLE B C CEILING 00mm B 400mm C 65mm 13

Fig. WITH ND WITHOUT PLENUM FORM: Terminal block Ceiling access Panel with air return Discharge air Return air Fig.3 DETIL : EXP NSION SCREW NUT FNCOIL RECOMMENDED THE DIMETER IS 6-8MM HNGING ROD FLT WSHER ir Duct Connection Circulatory air pressure drop should be within External Static Pressure Galvanized steel air ducts are suitable Make sure there is no leak of air. ir duct should be fireproof, refer to concerned country national and local regulations. Pipe Connection Using suitable fittings as water pipe connections. Refer to the specification The water inlet is on the bottom while outlet on top. The connection must be concealed with rubberized fabric to avoid leakage. Drainpipe can be PVC or steel. The suggested slope of the drainpipe is at least 1:50. Wiring 1) Wiring connection must be done according to the wiring diagram on the unit. ) The unit must be GROUNDED well. 3) n appropriate strain relief device must be used to attach the power wires to the terminal box. 4) 7/8 knockout hole is designed on the terminal box for field installation of the strain relief device. 5) Field wiring must be complied with the national security regulations. 14

Valve Kit The valve kit is applied for -pipe system. The kit consists of (refer structure figure 0): /3 way valve body is made of brass, maximum working pressure 1.6MPa. Electric actuator has the following specifications: -Power supply: 0V±10%/50/60Hz (±Hz) -ctivation: ON/OFF Hydraulic kit for the installation of the valve on the heat exchanger, complete with ball valves for adjusting the water flow and for closing the water circuit when perform maintenance to the unit. Y-strainer protects unit from impurity, increases the service life and insolating valves. Figure 0 ll parts of -way valve kit are indicated in the figure 1. ( For right pipe connection unit.) E F Ball valve B Brass connector C Y-strainer D Water inlet pipe E Water outlet pipe F -way valve D C B Figure 1 ll parts of 3-way valve kit are indicated in the figure. ( For right pipe connection unit.) F G C B Ball valve B Brass connector C Y-strainer D Connector pipe E Water inlet pipe F 3-way valve G Water outlet pipe E D Figure 15

Installation 1. Install the -way valve kit as indicated in the pictures of figure 3. (For right pipe connection unit.) s shown as detail, firstly take apart connector, then install 1 to unit with necessary sealing material. Fix between 1 and 3. t last tighten 3, make sure all of connectors are sealed.. Install the 3-way valve kit as indicated in the pictures of figure 4. (For right pipe connection unit.) Detail is as same as -way valve unit. The valve kit has been pre-assembled for easy installation. Where needed the connections are pre-coated with sealing material. The connections are not tightened for easy adjustment. fter determining the final position of the valve kit, tighten all connections to obtain water tightness. 09 65 WTER RETURN CONNECTION Rc3/4 WTER SUPPLY CONNECTION Rc3/4 03 0 Detail 146 Figure 3 -Way Valve 153 18 300 Detail WTER RETURN CONNECTION Rc3/4 WTER SUPPLY CONNECTION Rc3/4 10 10 16

Insulation 1. The insulation design and materials should be complying with local and national codes and regulations.. Chilled water pipes and all parts on the pipes should be insulated. The flow resistance of the connecting valve/hydraulic kit assembly is obtained from the following formula: P W = (Q W /100K v ) P W is the flow resistance (Pa) Q W is the water flow rate (m 3 /h) K v is the flow rate identified in the table Valve Model DN Conncetion Type Valve Type KV Shut-off Pressure Difference (MPa) MC-FCV3335G 0 Rc3/4" 3-way Valve 3.4 0.18 MC-FCV334G 0 Rc3/4" -way Valve 3.0 0.18 Pipe Connection 1. Using suitable fittings as water pipe connections with reference to the outline and dimensions.. The water inlet is on the bottom while outlet on top. 3. The connection must be concealed with rubberized fabric to avoid leakage. 4. Tightening torque should not be too high when connecting water pipes, in order to avoid brass deformation or water-leakage by torsion split. Wiring 1. Refer to the wiring diagram of the appropriate controller.. For connection with the DIKIN controller, position the water temperature probe into the appropriate position. Refer to the dedicated controller installation and operation manual. 17

Warning Daikin Industries, Ltd. s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorized importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. sk a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. sk a qualified installer or contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User s Manual carefully before using this product. The User s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. The air conditioners manufactured by Daikin Industries have received ISO 9001 series certification for quality assurance. Certificate Number. 9601019 The airconditioning factories of Daikin Industries have received environmental management system standard ISO 14001 certification. Certificate Number. EMS8036 Cautions on product corrosion 1. The units should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.. If the unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the unit close to the sea shore, contact your local distributor. Dealer Head Office: Umeda Center Bldg., -4-1, Nakazaki-Nishi, Kita-ku, Osaka, 530-833 Japan Tokyo Office: JR Shinagawa East Bldg., -18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ ll rights reserved Printed with soy ink. Literature No.: ED-FWW-V-01401 Supersedes: ED-FWW-V-01310