Last Amended on 11.11.2014 Page 1 of 6 I. DIMENSION 1. Dial/ Digital Vernier Caliper $ L.C.: 0.01mm Φ 0 to 200 mm 7.5 µm Using Slip Gauge Set & L.C.: 0.01mm Φ 0 to 300 mm 12.17 µm Using Slip Gauges & Caliper Checker 0 to 600 mm 18 µm 2. Plain Plug Gauges $ Upto 25 mm 2.0 µm Using Digital (GO & NOGO) Upto 150 mm 2. Upto 25 mm 1.2 µm Using Slip Gauges 3. Snap Gauges $ (GO & NOGO) Upto 100 mm Upto 300 mm 2.3 µm 2.8 µm 4. $ L.C.: 0.001 mm Φ 0 to 25 mm 1.2 µm 25 mm to150 mm 2.8 µm Using Slip Gauge Set & Gauge Block L.C.: 0.01 mm 150 mm to 500 mm 11 µm
Last Amended on 11.11.2014 Page 2 of 6 5. $ Setting rods 50 mm 2.0 100 mm 2.75 µm 500 mm 10.7 µm Using Slip Gauge Set, Gauge Block & 6. Depth $ 0 to 150 mm 7 µm Using Slip Gauges & L.C.: 0.01 mm Surface Plate 7. Inside $ 5 mm to 100 mm 6.2 µm Using Slip Gauge Set, L.C.: 0.01 mm 100 mm to 500 mm 13 µm Gauge Block & 8. Dial Calibration Tester $ L.C.: 0.0001 mm Φ 0 to 25 mm 0. Using Slip Gauges 9. Dial Indicator / Dial Test Indicator $ L.C.:0.01 mm mm 0 to 1 mm 0 to 10 mm 0 to 20 mm Using Dial Calibration Tester L.C.: 0.001 mm 0 to 1 mm 0 to 10 mm 0 to 20 mm 0 to 50 mm 0.713 µm 1.5 µm 1.5 µm L.C.: 0.002 mm 0 to 0.2 mm 1.2 µm Using Slip Gauges & Surface Plate
Last Amended on 11.11.2014 Page 3 of 6 10. Height Gauge $ L.C.: 0.01 mm Φ 0 to 300 mm 10 µm Using Slip Gauge Set & 0 to 450 mm 12 µm Lever Type Dial Gauge L.C.: 0.01 mm Φ 0 to 600 mm 17 µm Using Slip Gauge Set, Caliper Checker & Lever Type Dial Gauges 11. Surface Plate $ 1000 mm x 1000 mm 1.5x( L+W/150) µm ( L & W in mm) Using Electronic Level 12. Feeler Gauge $ 0 to 1 mm 1.8 µm Using Digital 13. Pin Gauge $ 0 to 30 mm 1.9 µm Using Digital 14. Thread Plug $ Gauge / Wear Check Plug Gauge 0 to 25 mm 3.2 µm Using Three Wire Unit 25 mm to 150 mm 4.5 µm Set & Digital 15. Combination Set $ 0 to 180 35' Using Angle Gauge L.C.: 1 16. Bevel Protector $ 0 to 360 4' Using Angle Gauge L.C.: 5' 17. Caliper Checker $ 0 to 600 mm 9.3 µm Using Slip Gauges, Length Bar
Last Amended on 11.11.2014 Page 4 of 6 18. Height Master $ 0 to 600 mm 12 µm Using Slip Gauges & 19. V Block $ Upto 200 mm 5.7 µm Using Dial Indicator, (Squareness, Flatness, Standard Mandrel & Parallelism) Angle Gauge 20. Bore Gauge $ Upto 150 mm 4.2 µm Using Dial Calibration Tester 21. Steel Scale $ L.C.: 0.5mm Φ Upto 2000 mm 0.28x( L/200) mm ( L in mm) Using Profile Projector 22. Radius Gauge $ Upto 25 mm 5 µm Using Profile Projector 23. Tri Square $ 90 16'' Using Profile Projector 24. Sieve $ 0.03 mm to 25 mm 25 mm to 200 mm 4 µm 14 µm Using Profile Projector Using Digital Caliper 25. Pitch Gauge $ (Pitch & Flank Angle) Upto 5mm 4 µm Using Profile Projector 60 3' 26. Ford Cup $ Dia : Upto 10 mm 5.5 µm Using Profile Projector 27. Standard Foil $ Upto 2 mm 1.3 µm Using
Last Amended on 11.11.2014 Page 5 of 6 28. Coating Thickness Gauge $ 0 to100 µm 1.5 µm Using Standard Foils Upto 1200 µm 1.5 µm 29. Comparator Stand # Upto 300 mm 1.5x( L+W/150) µm ( L & W in mm) Using Electronic Level 30. Inside Dial Caliper $ 5 mm to 300 mm 8 µm Using Slip Gauges & 31. Dial Thickness Tester $ L.C: 0.001 0 to 1 mm 0.8 µm Using Slip Gauge Set L.C: 0.01 Φ 0 to 50 mm 6.0 µm 32. Electronic Probe $ 0 to 25 mm 0.9 µm Using Slip Gauges Set L.C: 0.001mm 33. Profile Projector i) X/Y Axis Movement 0 to 300 mm 4.3 Using Slip Gauge, L.C.0.001 mm ii) Angle L.C: 1" 0 to 360 o 30" Angle Gauges & ii) Magnification 10X to100x 0.40 % Digital Caliper 34. Surface Plate 2000 mm x 2000 mm 1.5x( L+W/150) µm ( L & W in mm) Using Electronic Level 35. Bench Centre Upto 300 mm 5 µm Using Dial Indicator & Standard Mandrel
Last Amended on 11.11.2014 Page 6 of 6 II. MASS 1. Weighing Balance >5 g to 200 g 6 mg Using F2 Class Weights >200 g to 1 kg 28 mg As Per OIML R 76 >1 kg to 30 kg 2 gm III. PRESSURE & VACUUM >30 kg to 300 kg 10 gm Using M2 Class Weights As Per OIML R 76 1. Pressure gauge $ (Analog /Digital/ Transmitter / Switch) 0.2 bar to 30 bar 30 bar to 700 bar 1.2% Rdg 1% Rdg Using Digital Pressure Gauge Comparator 2. Vacuum gauge $ (Dial/Digital/ Transmitter / Switch) 3. Pressure gauge $ (Analog, Digital, Transmittors, Switch) -0.8 bar to 0 bar 1.9% Rdg Using Digital Pressure Indicator & Hand Held Pump 0 bar to 300 bar 3 bar Using Digital Pressure Gauge, Comparator * Measurement Capability is expressed as an uncertainty ( ) at a confidence probability of 95% $ Only in Permanent Laboratory Only for Site Calibration # The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual environmental conditions and master equipment used. Φ Laboratory can also calibrate instruments/devices of coarser resolution / least count within the accredited range using same reference standard/ master equipment under the scope of accreditation.