AFL FLOODLIGHT SERIES

Similar documents
SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

SXPJ SERIES S X azz.com/rigalite

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

MAR SERIES Fluorescent Lighting for Hazardous Locations

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

ORDERING INFORMATION: 120 Volts (120)

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens


PGL350P W PS Wallpack

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

Overall Dimensions. Specifications

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

OP2 CosmoPolis Series

DuraPro Hazardous Area Fluorescent

Overall Dimensions. Specifications

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials. Certifications and Compliances

Applications. Standard Materials

Haz. HazMax Summit/ss TECHNICAL SPECIFICATIONS

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

Rig-A-Lite LED Luminaire Guide. Superior LED Technology for Hazardous and Severe Environments. Five-Year Warranty

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

Perimaliter Wallpacks

Perimaliter Wallpacks

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

N2MV Series W Non-metallic

MagnaPro Hazardous Area Drop Lens Fluorescent

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Areamaster LED Flood/High Bay Luminaires

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP072A0812

KH Series Kemlux III Enclosed/Gasketed

KAD250MR3TBSPD04 Wall Fixture

NMF 2 SERIES Non-Metallic Enclosed and Gasketed Fluorescent Lighting for Wet and Damp Locations

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

Dual Lamp Ceramic Metal Halide 3 Lumen Packages in 1 Luminaire

Options. Pole and Arm. Suitable for wet locations

1000W and 2000W versions

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

Lighting: Explosionproof Area HID. Applications. Standard Materials

IMPACT FLOODLIGHT Architectural Flood Luminaire

Standard Grade 14 Inch Reflector. Ordering Information

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

F Series (available MF Series: Marine Listed with optional hazardous location listing)

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

H700 H710 H720. Compact Flood. Typical Applications. Features. Lamp Types. Approvals SPECIALTY LANDSCAPE

EAL Series. Effex Area Luminaire, W HID. Overall Dimensions. Specifications Approvals: Catalog Number: Date: Page 1 of 6

CALL TODAY!

Champ Fixtures. Class I, Division 2 Class I, Zone 2. Floodlight

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

Floodlight. AF1000 Series. Aktra Cutoff Floodlight W HID

TORNADOTM BOLLARD PATENTS PENDING

Laredo Decorative Wallpack Family

Laredo - Decorative Wallpack Family

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

MOGUL BASE HID FIXTURES

Introduction. Porcelain 4KV pulse rated medium/mogul base socket Silicone gasket

Taxonomies, Classifications, and Categories WHITE POWDER COATED DIE CAST ALUMINUM GUARD

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

CD20S2 DENVER. Luminaire. Optics. Sources Lamp 4K = High power LED, 4000K (neutral white) ±150K.

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

C O N T R A S T NORTH STAR LIGHTING INC. A R C H I T E C T U R A L F L O O D L I G H T S E R I E S

LUM SERIES-PLED w/ POLE RATED FOR 100MPH SHAFT

Hubbell Lighting Expressline Family 2009

VINCI-LED Wall/Area/Flood Lighting

DMV Series W For Combustible Dusts

FULL CUTOFF DARK SKY COMPLIANT FIXTURES. commercial & architectural lighting

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Quick Facts LED DIRECTIONAL FIXTURES

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

kenall dark sky luminaires

Transcription:

AFL FLOODLIGHT SERIES A FL Flood Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB & IIC CUL Cast Aluminum 55 C Ambient Temperature (AFL series)

AFL FLOODLIGHT SERIES Flood Lighting for Hazardous Locations Precision formed specular reflector for optimum photometric and lighting performance. Hinged copper-free cast aluminum lens frame with stainless steel slotted hex head captive screws. Front opening for easy relamping and ballast access. All exposed hardware is marine grade. Thermal, shock, heat and impact resistant tempered clear glass lens. One-piece copper-free cast aluminum lamp and ballast housing with baked on bronze polyester powder coat finish. Weather resistant high temperature silicone or neoprene lens and lens door gasket assures long service life. Sturdy mounting yoke.

METAL HALIDE HIGH PRESSURE SODIUM Catalog Number Logic AFL 40-S-04-T-66-XX 2 3 4 5 6 7 2 3 BASIC SERIES AFL Floodlight Series (i) AFL = 70-400 Watt Metal Halide and High Pressure Sodium Class l, Division 2, Groups A, B, C & D Zone 2, Groups IIA, IIB and IIC UL 844 Hazardous Locations UL 598A Marine Outside Type CUL (ii) AFL2 = 875W & 000W Metal Halide UL 598A Marine Outside Type (iii) AFL5 = 000W High Pressure Sodium Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 598A Marine Outside Type LAMP CURRENT/LAMP WATTAGE 07 = 70 Watt 0 = 00 Watt 5 = 50 Watt 7 = 75 Watt 25 = 250 Watt 32 = 320 Watt 35 = 350 Watt 40 = 400 Watt 875 = 875 Watt 00 = 000 Watt LAMP TYPE (MOGUL BASE) S = High Pressure Sodium (70, 00, 50, 200, 250, 400 & 000 Watt) H = Metal Halide (70, 00, 50, 75, 250, 320, 350, 400, 875 & 000 Watt) 4 5 6 7 BALLAST VOLTAGE 04 = Multi-Tap (20, 208, 240 & 277V) 2 = 20V 60 HZ 20 = 208V 60 HZ 22 = 220V 50 HZ 24 = 240V 60 HZ 27 = 277V 60 HZ 34 = 347V 60 HZ 48 = 480V 60 HZ MOUNTING T = Trunnion BEAM SPREAD 76 = 7V X 6H 6 67 = 5V X 7H 6 66 = 6V X 6H 55 = 5V X 5H 6 OPTIONS Q = Auxiliary Quartz Relay QTD = Auxiliary Quartz Relay Hot and Cold Start PC = Photo Cell 3 V = Visor LS = Lamp Support FB = Single Fuse Block 2,3,4 FB2 = Double Fuse Block 2,3, PL = Clear Acrylic Shield SMS = Shock Mounted Socket SC = Safety Cable (Eye Bold Included) PS = Pulse Start 5 R = Instant Restrike (HPS only up to 50W) Consult factory for pricing. 2 Limited to 75W Maximum HID Lamp 3 Not suitable for hazardous locations. 4 Not available with multi-tap ballast unless incoming voltage is specified. When installed, one fuse block/fuse holder is provided for 20, 277V. Fuse not included. Option not available for marine listed fixtures. 5 Use universal or appropriate position oriented lamp. 6 AFL 2 & 5 only. Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts. www.rigalite.com

METAL HALIDE HIGH PRESSURE SODIUM Shown with optional visor. Class I, Division 2, Groups A,B,C and D (See below for suitability as designated for ➀,➁ or ➂) UL 844 Hazardous Locations UL 598A Marine Outside Type Zone 2, Groups IIA, IIB and IIC One-piece copper-free cast aluminum lamp and ballast housing with baked on bronze polyester powder coat finish Precision formed specular finished reflector for optimum photometric performance Thermal shock, heat and impact-resistant tempered glass lens Marine grade hardware 55 C Ambient Temperature (AFL Series) (Lamps not included) Lamp Shipping Fixture Type Figure Number Wattage Voltage Catalog Number Weight (Lbs.) High Pressure Sodium Metal Halide 5 2 70 00 50 250 400 000 75 250 320 350 400 000 Multi-Tap* AFL07-S-04-T-66 ➀➁➂ 34.0 480V/60HZ AFL07-S-48-T-66 ➀➁➂ 34.0 Multi-Tap* AFL0-S-04-T-66 ➀➁➂ 34.0 480V/60HZ AFL0-S-48-T-66 ➀➁➂ 34.0 Multi-Tap* AFL5-S-04-T-66 ➀➁➂ 34.0 480V/60HZ AFL5-S-48-T-66➀➁➂ 34.0 Multi-Tap* AFL25-S-04-T-66➀➁➂ 37.0 480V/60HZ AFL25-S-48-T-66 ➀➁➂ 36.5 Multi-Tap* AFL40-S-04-T-66 ➀➁➂ 39.5 480V/60HZ AFL40-S-48-T-66 ➀➁➂ 39.0 Multi-Tap* AFL500-S-04-T-76 ➀➁ 65.5 480V/60HZ AFL500-S-48-T-76 ➀➁ 65.0 Multi-Tap* AFL7-H-04-T-66-PS ➀➁ 35.0 480V/60HZ AFL7-H-48-T-66-PS ➀➁ 35.0 Multi-Tap* AFL25-H-04-T-66-PS ➀➁➂ 35.0 480V/60HZ AFL25-H-48-T-66-PS➀➁➂ 34.0 Multi-Tap* AFL32-H-04-T-66-PS ➀➁➂ 39.5 480V/60HZ AFL32-H-48-T-66-PS➀➁➂ 39.0 Multi-Tap* AFL35-H-04-T-66 ➀➁➂ 36.5 480V/60HZ AFL35-H-48-T-66 ➀➁➂ 36.5 Multi-Tap* AFL40-H-04-T-66 ➀➁➂ 36.5 480V/60HZ AFL40-H-48-T-66 ➀➁➂ 36.5 Multi- Tap* AFL200-H-04-T-66 ➁ 77.0 480V/60HZ AFL200-H-48-T-66 ➁ 77.0 *20/208/240/277V 60HZ ➀ Class I, Division 2, UL 844 Listed ➁ UL 598A Listed ➂ CUL

Certification Guide METAL HALIDE HIGH PRESSURE SODIUM Model Lamp Ambient Class I, Division 2 Supply Wire Suitable Temperature C Groups A,B, C & D Temperature C AFL40 MH 55 T (350 C) 05 AFL25 MH 55 T (325 C) 90 AFL7 MH 55 T(325 C) 90 AFL5 MH 55 T (325 C) 90 AFL40 HPS 55 T(450 C) 05 AFL25 HPS 55 T (350 C) 90 AFL5 HPS 55 T (350 C) 90 AFL500 HPS 25 T 90 Accessories NOTE: FLB-3 and FLB-5 fit 2 in. to 2-/2 in. pipe size (2-3/8 in. to 2-7/8 in. O.D.) 80 YOKE Horizontal Mounting Kit 80 Adjustment, Includes (2) /2 in. Bolts Catalog Number: FLB-2 Shipping Weight:.4 lbs. 90 YOKE Horizontal Mounting Kit 90 Adjustment, Includes (2) /2 in. Bolts Catalog Number: FLB-2-90 Shipping Weight:.3 lbs. 45 YOKE Horizontal Mounting Kit 45 Adjustment, Includes (2) /2 in. Bolts Catalog Number: FLB-2-45 Shipping Weight:.5 lbs. Wall or Pole Mounting Kit Wall or Pole Mount, Includes (2) U-Bolts Catalog Number: FLB-3 Shipping Weight: 3.6 lbs. www.rigalite.com Pole Top Mounting Kit Gasket Wiring Compartment Adapts Horizontal or Vertical Mounting Yokes, Includes (3) Set Screws, Catalog Number: FLB-5 Shipping Weight: 3.2 lbs.

METAL HALIDE HIGH PRESSURE SODIUM Fixture Dimensions (inches) AFL FIGURE AFL2 FIGURE 2 EFFECTIVE PROJECTED AREA 2.0 sq. ft. 75-400 Watt Metal Halide 70-400 High Pressure Sodium EFFECTIVE PROJECTED AREA 4.40 sq. ft. 000 Watt Metal Halide AFL5 FIGURE 3 EFFECTIVE PROJECTED AREA 3.02 sq. ft. 000 Watt High Pressure Sodium