Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Similar documents
Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

Areamaster LED Flood/High Bay Luminaires

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Applications. Straight Stanchion-Mount Fixture with Prismatic Glass Refractor and Guard. Pendant Mount Fixture with Prismatic Glass Refractor

Applications. Standard Materials

AFL FLOODLIGHT SERIES

Applications. Standard Materials. Certifications and Compliances

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

Lighting: Explosionproof Area HID. Applications. Standard Materials

Applications. Standard Materials. Certifications and Compliances

G1-24. Applications UL listed for marine type electric fixtures--outside. Ideal in Class I, Div. 1 and 2 installations

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

KAD250MR3TBSPD04 Wall Fixture

N2MV Series W Non-metallic

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

Applications. Illustrated Features

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

Champ Fixtures. Class I, Division 2 Class I, Zone 2. Floodlight


SXPJ SERIES S X. HID & Compact Fluorescent Lighting for Hazardous and Hostile Locations

Mercmaster II HID Luminaires High Pressure Sodium and Pulse Start Metal Halide. Mogul Base UNILETS for Use with Threaded Metal Conduit.

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

AerolumeTM. Collection. Area Luminaires 3 Fixture Sizes W HID 64/80/120

KH Series Kemlux III Enclosed/Gasketed

Overall Dimensions. Specifications

CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Type 4X Exd IIB + H 2 3/4 CAP-75 1 CAP-100

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Overall Dimensions. Specifications

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Perimaliter Wallpacks

ORDERING INFORMATION: 120 Volts (120)

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

SXPJ SERIES S X azz.com/rigalite

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

A2CO Series. Aktra II Cutoff Floodlight, W HID. Overall Dimensions. Specifications EPA Effective Projected Area.

Standard Grade 14 Inch Reflector. Ordering Information

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

F1-1. HID Lighting: Enclosed and Gasketed. Description. 2, 3 Mercmaster III Family Tree Mercmaster III HID Low Profile Lighting Fixtures

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

LOW PROFILE LINEAR ALUMINUM LED EXCLUSIVE DESIGN FEATURES

SAF SERIES Hazardous Location Mogul Base HID and Compact Flourescent

DMV Series W For Combustible Dusts

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

G1-1. HID Lighting Fixtures: Explosionproof, Dust-Ignitionproof. Page Description

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

WPP25 250W MP Wal-Pak Borosilicate Glass Hinged/Removabl

PGL350P W PS Wallpack

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

Haz. HazMax Summit/ss TECHNICAL SPECIFICATIONS

OP2 CosmoPolis Series

Perimaliter Wallpacks

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

DuraPro Hazardous Area Fluorescent

Post Top Globes. ACL Large Acorn Post Top Globe Page 109. ACS Small Acorn Post Top Globe Page 109

80 Watt Multi-Purpose LED Area Light

Heavy industrial LED lighting Champ Pro PFM LED luminaires. Champ PFM. LED floodlights for heavy industrial areas. Authorized Distributor

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

MagnaPro Hazardous Area Drop Lens Fluorescent

Code Master 2 Factory Sealed Induction Lighting System Explosionproof

WFH LED SERIES L E D. High-Bay Lighting for Hazardous & Wet Locations

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES HIGH MAST TYPE

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

DECORATIVE. Tear Drop Series

FULL CUTOFF DARK SKY COMPLIANT FIXTURES. commercial & architectural lighting

ORDERING INFORMATION: 120 Volts (120) 208 Volts (208) 240 Volts (240) 277 Volts (277) 480 Volts (480)

Hazardous Area LED Lighting Champ FMV LED Luminaires. Champ FMV. LED floodlights for harsh and hazardous areas

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

MVOLT

Bavaria Downs. Chaska, MN. Lighting

WFHN LED SERIES W F H N L E D. High-Bay Lighting for Heavy Hose-Down Environments

SAFR LED S A F R L E D. LED Area Lighting for Hazardous Locations

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Standard Grade 23 Inch Reflector/Refractor. Ordering Information. series wattage source voltage optics color options options BL-LB1

Floodlighting Accessories

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Predator Medium Floodlight Wet Location

Transcription:

A, IIB, IIC Applications Powerful, efficient weatherproof lighting for large areas such as: Pulp and paper mills Processing plants Chemical plants Oil refineries Foundries Storage areas Waste and sewage treatment Parking garages Other areas where dust, water, dirt and rough usage are a problem Features Highly efficient, integrally ballasted floodlight. Has compact, lightweight, yet rugged diecast aluminum construction. Combines architecturally beautiful design with rugged dependability, simple installation and maintenance. Easy to install and service. A wide range of ballasts and voltages are available for both domestic and export applications. Integral ballast. One-piece housing. One-piece lens cover. Secured by five 1/4 Dia. captive stainless steel slotted hex-head bolts. Thermal shock and impact resistant glass lens. Heavy duty, high temperature silicone rubber gasket, firmly seated. Heavy duty mogul-base porcelain socket with heavy gauge brass, nickel-plated, double lamp-grip screw shell and springloaded center contact. Compound parabolic, double segment, finished aluminum reflector for optimum efficiency. Yoke mount, zinc plated steel yoke with architectural bronze polyester finish. 3/4 NPT tapped hub for power entry. Standard Materials Ballast housing and lens door: copperfree (4/10 of 1% max.) aluminum Gasket: silicone rubber Socket: heavy duty porcelain with heavy gauge brass shell Reflector: finished aluminum Yoke mount: zinc plated steel Bolts: stainless steel Standard Finishes Ballast housing, lens cover, yoke and pole mount: architectural bronze polyester Socket: nickel-plated NEC/CEC Certifications and Compliances UL Standard: UL 1598, UL 844 UL Listed: E10794 Yoke Projected Area: 3.36 Sq. Ft. 403

Order using catalog numbering guide below or select catalog number from tables on following pages. Catalog Numbering Guide For Areamaster 1000 Floodlights GAM 86 1 H MT FN I2 Series: Areamaster 1000 Series Wattage: 86-1000 W HPS, MH, PSMH Mounting: 1 - Yoke : H - Metal Halide L - High Pressure Sodium P - Pulse Start Metal Halide Voltage: MT - 120/208/240/277-60 Hz, CWA TT - 120/277/347-60 HZ, CWA 48-480 - 60 Hz, CWA C7-600 - 60 Hz, CWI Options: E40 - E-40 Socket (self certified) FN - 120V Integral Fuse FP - 208V Integral Fuse FS - 240V Integral Fuse FT - 277V Integral Fuse FF - 480V Integral Fuse L - HID Q1 - Photocontrol 120 V Q2 - Photocontrol 208-277 V Q3 - Photocontrol 347 V Hazardous Rating: I2 - Division 2 Z - Ex nr T Numbers Represent the Maximum Temperature for Class I, Division 2 Locations and Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations. T Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Range ( C) Range ( ºF) 351-450 664-842 326-350 619-662 301-325 574-617 281-300 538-572 261-280 502-536 231-260 448-500 216-230 421-446 201-215 394-419 181-200 358-392 166-180 331-356 161-165 322-329 136-160 277-320 121-135 250-275 101-120 214-248 86-100 187-212 85 185 T Numbers Represent the Maximum Surface Temperature for Luminaires with AEx na nr or AEx nr rating T Number T1 T2 T3 T4 T5 T6 Range ( C) 301-450 201-300 136-200 101-135 86-100 85 Range ( F) 547-842 394-572 277-392 214-275 187-212 185 For CEC 480 V, 60 Hz, consult factory. Not for available for PSMH versions. Certified to meet the National Electrical Code (NEC) only. 404

Watts Line Voltage High Pressure Sodium Weight kg (lb) Volume dm 3 (in 3 ) NEC/CEC Class 1, Division 2 Catalog Number G-AM861L-MT-I/2 CEC Class I, Zone 2, Ex nr Catalog Number G-AM861L-MT-Z 1000 120/277/347 G-AM861L-TT-I/2 G-AM861L-TT-Z 1000 480 G-AM861L-48-I/2 G-AM861L-48-Z 1000 600 G-AM861L-C7-I/2 G-AM861L-C7-Z Metal Halide G-AM861H-MT-I/2 G-AM861H-MT-Z 1000 120/277/347 G-AM861H-TT-I/2 G-AM861H-TT-Z 1000 480 G-AM861H-48-I/2 G-AM861H-48-Z 1000 600 G-AM861H-C7-I/2 G-AM861H-C7-Z Pulse Start Metal Halide G-AM861P-MT-I/2 1000 480 G-AM861P-48-I/2 Dimensions in Millimeters (Inches) Yoke Mount Supplied complete with CWI Isolated Secondary Ballast for 600 Vac. Certified to meet the National Electrical Code (NEC) only. 405

Description Catalog Numbers Crossarm Mounting Bracket Pipe or Wall Mount Bracket Poletop Slip-Fitter Has 180 horizontal adjustment degree marked. Facilitates mounting floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed, architectural bronze polyester finish. Used with G-AM-8-CA. Clamps to 1 to 2-1/2 pipe, vertical or horizontal, or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster finish. Slip-fits 1-1/2 or 2 pipe size poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate sealed, with cast aluminum cap. Assembly has architectural bronze polyester finish. G-AM-8-CA G-AM-8-WB G-SF20 Slip-fits 2 or 2-1/2 poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyester finish. G-AM-8-SF Locking- Photocontrol Receptacle For NEMA type photocontrol, with installation hardware and instructions. G-1PCR Vandal Shield UV stabilized polycarbonate, with installation hardware and instructions. G-AM-8-NVS Top Visor Easy to install with hardware supplied. Aluminum, with architectural bronze polyester finish. G-AM-6-NV 406

Photometric Data Typical Footcandle Values Mtg. Ht. M (Ft) Footcandle Values for Iso Footcandle Lines A B C D E F 1000W HPS Clear, 140,000 Lumens, Cat. No. G-AM861L-MT 18.3 (60) 8.0 3.0 1.0 0.5 0.20 0.10 15.2 (50) 11.5 4.6 1.5 0.72 0.27 0.15 12.2 (40) 17.3 6.8 2.4 1.0 0.45 0.21 9.1 (30) 31.5 12 4.1 1.9 0.80 0.30 1000W MH Clear, 110,000 Lumens, Cat. No. G-AM861H-MT 18.3 (60) 6.0 3 1.0 0.5 0.20 0.10 15.2 (50) 8.2 4.2 1.4 0.8 0.28 0.15 12.2 (40) 12.6 7.9 2.3 1.2 0.42 0.19 9.1 (30) 23.0 11.6 4.0 2.1 0.70 0.25 Photometric Data HPS MH PSMH Horiz. Spread 134 133 Vert. Spread 131 124 Beam Lumens 77,440 62,112 Beam Effic. 55.3% 56.5% Max. CP 40,251 45,909 Avg. Max. CP 38,396 38,490 Total Lumens 80,846 66,008 Total Effic. 57.7% 60.0% Electrical Specifications Line Voltage of Ballast Starting Amps Operating Amps Total Watts 1000 Watt High Pressure Sodium HPS 120 CWA 6.35 9.50 1100 HPS 208 CWA 3.80 5.50 1100 HPS 240 CWA 3.20 4.80 1100 HPS 277 CWA 2.75 4.20 1100 HPS 347 CWA 2.20 3.30 1100 HPS 480 CWA 1.80 2.45 1100 1000 Watt Metal Halide MH 120 CWA 8.00 9.20 1080 MH 208 CWA 4.60 5.30 1080 MH 240 CWA 4.00 4.60 1080 MH 277 CWA 3.50 4.00 1080 MH 347 CWA 2.50 3.20 1080 MH 480 CWA 2.00 2.30 1080 1000 Watt Pulse Start PSMH 120 Super CWA 8.30 8.50 1065 PSMH 208 Super CWA 4.70 5.00 1065 PSMH 240 Super CWA 4.00 4.40 1065 PSMH 277 Super CWA 3.40 3.80 1065 PSMH 480 Super CWA 2.00 2.30 1075 T Numbers and Temperature Ratings Areamaster 1000 Ambient Fixture Wattage Fixture T Ratings C ( F) T Rating Temperature Range C ( F) 1000 HPS Class I Div 2 350 40 (104) 301-350 (574-662) 1000 HPS Ex nr IIC T3 40 (104) 136-200 (277-392) 1000 PSMH Class I Div 2 T1 40 (104) 301-450 (574-842) Photometric charts available on request. i.e., ratio of distance to height. Example: @ 6.1 meters (20 feet) mounting height, 1 means 6.1 meters (20 feet); 2 means 12.2 meters (40 feet), etc. 407