Active Evacuation System (AES)

Similar documents
Environmental Series Air Curtains

Operators Manual OC6000 & OC6200

High Velocity Series Air Curtains

Veterinary Anesthesia Gas Scavenging System (Active)

WF-5100 Series True Sine Wave Inverters

Veterinary Scavenger Interface

INSTALLATION & OWNER'S MANUAL

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

SUBMERSIBLE SUMP PUMPS

Air Curtain. Installation, Operating and Maintenance Instructions

VANGUARD A EZ INSTALL OPERATOR S MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

1000 Watt Pure Sine Wave Power Inverter, Users Manual

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

SUPER PUMP OUT SYSTEM

WELDING FUME EXHAUSTERS & ARMS

ESE Series Cast Iron Sewage Pumps

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

Kitchen Tech Series Air Curtain

POWER GEAR SLIDE-OUT MANUAL

Dispenser & Warmer RIC-1909 RIC-1909EXP

WF-5110R True Sine Wave Inverter

Power Inverter 400 MW Owner s Manual

D-Series Blowers and Exhausters

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

3000W POWER INVERTER. User Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

User s Manual D-Series Blowers and Exhausters

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

SUBMERSIBLE SUMP PUMPS

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

IMPORTANT SAFETY INSTRUCTIONS

PRE-PLUMBED SEWAGE SYSTEM

PowerAir Compressor Installation

Matala. VersiFlow Series. Instruction and Maintenance Manual

Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Omniaire 1000V Instruction Manual-8/05

Instruction Sheet EWR SERIES EWR WALL CABINET R

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

ActuLink ABS Module - ABS-MOD-400

Operator s Safety and Service Manual

WF-5110R True Sine Wave Inverter

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

Service and Parts Guide: Matrx Central Scavenger Waste Anesthetic Gas Disposal System

WA 2719 ( 604 ) ( 604 ) , H.E.R.O.

Electronically Commutated Motor Wiring Manual

Hydraulic Immediate Need Power Pack

OWNERS MANUAL IMPORTANT: READ OWNERS MANUAL CAREFULLY MODEL # SQUARE CAT XT OSCILLATING FLOOR MACHINE

Air Curtain Motor/ Blower Assembly

Model 8144NC Fresh Air Ventilator

WIND STOPPING 14 (WMI) AND WIND STOPPING 16 (WMH) INDUSTRIAL SERIES

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

Model G14SD Vapor Management System

BZ Products Inc. U.S.A.

450250/ ROOSTER WINCH Installation Manual

30Deg.Two Motor Tandem

ClassicSeries Compressor Installation

QPET, QPETXU Battery Chargers

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

Operation Manual RANGE HOOD

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N


AUTOMATIC SUBMERSIBLE UTILITY PUMP

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Oil Pump Models L 5016, L 5116 & L 5132

NUTONE RANGE HOOD NTM SERIES

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

User Guide IGD Series

QSSE, QSSEX INDUSTRIAL Battery Chargers

Sealless Centrifugal Canned Motor Pumps

INSTALLATION. led fairing lights for gl

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY

WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES

Utility Distribution Systems Installation, Operation, and Maintenance Manual

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

SUNC3000 / Item #40885

Hawk Enterprises of Elkhart THE BRUTE Owner s Manual

MODEL 900 IMPELLER-TYPE FLOW METER

NO SINGLE STAGE PROGRESSIVE, TPS, RPM WINDOW SWITCH

Water Jetter Units DU JT50 / DU JT100

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

SHALLOW WELL JET PUMP

Table of Contents WARRANTY

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Pump Installation and Service Manual HRS Hydromatic Retractable System

Model AM2 M40 Panel Installation, Operation, and Maintenance Manual

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Hydraulic Bead Breaker Kit

Transcription:

Active Evacuation System (AES) Model EVC3000 FOR VETERINARY USE ONLY - 1 -

IMPORTAINT INFORMATION READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. CAUTION For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b) Ducted fans must always be vented to the outdoors. THERE ARE NO USER SERVICEABLE PARTS INSIDE Contact lei medical directly for all maintenance and repairs. Technical service phone 877-620-1500 Symbol Chart This document uses the following symbols to indicate potential hazards or alert the user to useful information about the unit. Important Notice Explanation needed: refer to this manual High Voltage: Risk of Electrical Shock Protective Earth Ground - 2 -

INSTALLATION INSTRUCTIONS 1. Remove the panel to reveal the terminal block. 2. Attach the ground. 3. Attach the L1 and N wires to the terminal block. ATTENTION! DO NOT TAMPER WITH THIS SCREW NOT TO BE USED AS THE EARTH GROUND Earth Ground L1 N - 3 -

SUGGESTED MOUNTING INFORMATION The area around the AES must be free of loose dirt and debris The area should be well ventilated with a maximum temperature of 120 deg. F For maximum performance, the AES should be centrally located to your evacuation locations if possible Need help with your design? offers free design consultation for evacuation systems. Call toll free 877-620-1500 or e-mail CS@superavet.com - 4 -

INSTALLATION Wall mounting bracket Supplied, but NOT attached INTAKE 2 female sch40 ABS or PVC EXHAUST 2 male sch40 ABS or PVC Shelf mounting bracket Supplied, but NOT attached - 5 -

OPERATION Hour Meter ON/OFF switch The ON/OFF switch has a built in resettable circuit breaker. When activated, the switch will be in a central position. To reset, toggle the switch to the OFF position then to the ON position. - 6 -

RECOMMENDED GUIDELINES POWER SWITCH We recommend controlling the EVC3000 through a lighted power switch to indicate the device is powered ON. INTAKE For the intake of the AES, we recommend installing 2 Schedule 40 PVC pipe as the main line to the general area of the evacuation outlets. Use ½ Schedule 40 PVC pipe from the main 2 pipe to the evacuation outlets in the ceiling or walls. EXHAUST The exhaust pipe should be 2 pipe plumbed to outside the building. OUTLETS We recommend using the EVC680 waste gas outlets with the AES. These have engineered flow rate compensators to balance the entire system. No ceiling or wall valves are needed to control the flow rate, however, all active (suction style) evacuation systems require waste gas interface balance valves on the anesthesia machines. WASTE GAS INTERFACE The EVC630 WGI is engineered for this system and requires no additional calibration or maintenance. It is mounted on the anesthesia machine and attaches to the pop off valve or non-rebreathing system via the blue 19mm tubing. - 7 -

GENERAL INFORMATION Active Evacuation System AES anesthetic evacuation system utilizes a sealed evacuation unit to remove waste gas to the outside air. The AES wall or ceiling outlets are plumbed using PVC pipe, and are connected to the anesthesia machine through the waste gas interface (WGI) device to balance the negative pressure. Because of the lower volume of the AES system, no flow regulator is required at the WGI. 1-10 Anesthesia Machines Uses EVC680 wall/ceiling outlets Plumbed using PVC pipe, not copper Uses waste gas interface EVC630 to balance evacuation pressure on each anesthesia machine. MAINTENACE This AES unit is maintenance free. TROUBLE SHOOTING 1. The fan stops flowing air. Check the on/off switch. If the switch is half way on/off, the circuit breaker has been triggered. Reset the switch into the ON position. 2. The fan is on but not flowing air at the outlets. Check the exhaust pipe for obstructions (animals, debris, etc.) Check the intake pipes for loose joints FOR ALL OTHER ISSUES CALL SUPERA LLC AT 1-877-620-1500 - 8 -

SPECIFICATIONS Tech Specs Item: PSC Blower RPM: 3388 Bearing Type: Ball Type: Forward Curve, Direct Drive CFM @ 0.000-In. SP: 53 CFM @ 0.200-In. SP: 50 CFM @ 0.400-In. SP: 41 CFM @ 0.500-In. SP: 23 Electrical Voltage: 115 Hz: 50/60 Phase: Single Full Load Amps: 0.30 Agency Compliance: TUV Listed for US and Canada requirements to UL507 Sound less than 50 decibels Construction 303 stainless steel housing ABS fittings Dimensions 10 X 7 X 8 Weight: 8 lbs. - 9 -

WARRANTY (PARTS ONLY) 5,000 hours or 5 years, whichever comes first. warrants this product shall be free from defects in workmanship and materials, under normal use from the date of purchase. This is a parts warranty. Labor is not included. warrants only that each such part and item shall be free from defects in workmanship and materials at the time of delivery. This warranty shall be void for any product that has been altered, defaced or removed from the original product. shall not be liable for any damage, injury or loss arising out of the use of the product, whether as a result of a defect in the product or otherwise, if, prior to such damage, injury or loss, the product was (1) damaged, misused, or misapplied; (2) repaired, altered or modified by persons other than ; (3) not installed in strict compliance with the applicable codes and ordinances; (4) not installed by Supera LLC or an authorized dealer. UNDER NO CIRCUMSTANCES SHALL SUPERA LLC BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES AS THOSE TERMS ARE DEFINED IN THE UNIFORM COMMERCIAL CODE. All items returned for service or repair, are the responsibility of the customer. Proper packing methods should be used in returning items to. - 10 -

SAMPLE SYSTEM LAYOUT - 11 -