House Hydrant V1 FROST-FREE OUTDOOR WALL HYDRANT. aqu r FLUSH-MOUNT NON-FREEZE SELF-DRAINING.

Similar documents
House Hydrant V2 FROST-FREE OUTDOOR WALL HYDRANT. aqu r FLUSH-MOUNT NON-FREEZE SELF-DRAINING ANTI-SIPHON.

House Hydrant Installation Instructions

Frost-Proof Wall Hydrant Installation, Use & Repair Guide

Instruction Manual Includes:

Paint/Solvent/Dump Valve and Flow-Through Valve

A. This Section includes the following domestic water piping specialties:

HOSE BOXES. Includes hose boxes, supply boxes & hose valves MORRIS GROUP INTERNATIONAL

MrPEX 1 ½ " Brass Manifold Installation Guide

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Installation and Maintenance Instructions

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

MUELLER Super Centurion fire hydrants

Installation Guidelines

DEMA Pro-Fill I Sink Dispenser

Installation/Care/Use Manual

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

DK Series Dialock Manual Diaphragm Valves Product Data Sheet

DEMA Pro-Fill II Sink Dispenser

Hose & Apparatus Test Equipment

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

# and # FAST Fuel System Kits

SECTION 2 FOOT & CHECK VALVES YARD HYDRANTS

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

BRASS & BRONZE VALVES

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

Halsey Taylor Owners Manual

PRESSURE REGULATORS. 0.6, 0.8, 1.1, 1.4, 1.8, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5 * Outlet pressure in bar (M 3/H)

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

WASHDOWN & PRESSURE WASH

CALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function

Installation/Care/Use Manual

GENERAL INSTALLATION MANUAL

Installation Instructions

CAPS & CONNECTORS. Rubber Caps (Special Heat Resistant EPDM Rubber) Ford - GM - Chrysler NYLON CONNECTORS

ANGLE BALL VALVES STRAIGHT BALL VALVES STRAIGHT BRASS BALL VALVES BARB BRASS BALL VALVES. Description STANDARD PORT BALL VALVES.

Manifold Isolation Valves

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

Mueller Super Centurion 250 Fire Hydrant

Data Sheet Issue A

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

Sec. 11 NYLON CONNECTORS

Installation Instructions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

SECTION 2 FOOT & CHECK VALVES YARD HYDRANTS

FOR TECHNICAL ASSISTANCE

Installation Instructions

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

Installation Instructions

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

introduction < STANDARDS >


VACUUM HOSES AND VALVES

Segment Name: CAST IRON 22X18 SERVICE SINK

Sanitary Roof Hydrant Installation Instructions

Sentinel 250 Fire Hydrant

PLUMBING VALVES TOTAL MAINTENANCE SOLUTIONS

Spray Clean 606T-2 Installation Instruction

Installation Guidelines

Installation Instructions

Slide Gate Hydrant Maintenance Manual

LK Manifold Shunt VS2

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

Installation Instructions

Brass Push-Type Fittings. Tube Thread. Part O.D. (M) NPT. No. in. in.

introduction RV Series Sediment Strainers Product Data Sheet

Awide choice of devices

PeroxiDraw Dispenser

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

K-Rain - Hydrotek Valves Instructions

Cascade Comfort Bathing Systems with Aqua-Aire Parts Breakdown & Assemblies

Initial Start-Up. What We Will Cover

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

SKID MARK GARAGE. Axillary Fuel Supply

METERS Data Collection CONTROL. Installation Guide. Residential Water Meters

Inverted High Pressure Fluid Filters

FREE INSTALLATION GUIDE. DripMaster. The best way to water plants, trees, shrubs, hanging baskets, and gardens SECTION 2 UP TO 70% WATER SAVINGS

Installation and Service Instructions

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

tubing, faucets and fittings

Single Handle Faucet, 4 Plate, Ceramic Cartridge, Extended Lever Handle with Pop-Up

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

Operations Manual. and. Seal Kit Replacement Guide

E-Mini Thermostatic Valve with Shut-Off or with Positive Shut-Off 2-Way Diverter

Circulation Kits for CP Pumps

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Material required for drilled well application (indoor use only)

Jones Stephens Corp. PlumBest LTConnections SECTION D - FITTINGS & VALVES. Brass Compression Fittings

Composite PEX-AL-PEX Tubing

earth safe Fuel Systems for Critical Power

DIG Corporation Irrigation product Specifications

5100 Series Inline Relief Valve 10 to 2,400 PSIG

Installation Instructions

Transcription:

House Hydrant V1 FROST-FREE OUTDOOR WALL HYDRANT FLUSH-MOUNT NON-FREEZE SELF-DRAINING www.aquorwatersystems.com

Overview and Feature List HOUSE HYDRANT V1 - IN-WALL OUTDOOR FAUCET SYSTEM Flush-mounted wall hydrant with twist-lock connection system. Allows user to access water instantly by connecting under full water pressure. Robust O-ring connection system ensures a reliable leak-proof seal, even at high water pressures. Stainless steel operating rod provides zero-maintenance reliability for years. Hydrant self-drains upon disconnection to provide freeze protection. Hydrant comes standard with 1/2 female NPT inlet. 90 elbow and other inlets available. Each hydrant kit includes polymer hose connector with 3/4 GHT threading. Any 3/4 accessory (eg. water timers, splitters, vacuum breakers) can be attached to end of hose connector. Hose connector contains integral check valve for backflow protection. Aquor hydrants are made with 100% lead-free 316L stainless steel and non-toxic polymers. No brass components are used. Complies with California, Vermont, and Federal Lead Reduction Law (Senate Bill S.3874) Color options: Aquor Blue, Slate Gray Stem lengths: 4-12 (custom lengths available) Inlet size: 1 2 female NPT (other options available) Supply line compatibility: All plumbing types (recommended: PEX) Exterior siding compatibility: All siding types (for uneven surfaces, use a mounting block) Recommended water pressure/temperature: 25-125 psi, 0-140 F Backflow protection: Check-valve in hose connector (anti-siphon can be added) Waranty: 10-Year Aquor Manufacturer s Warranty

Parts Assembly and Parts List 8 1 2 3 4 5 6 7 9 10 11 12 13 14 15 PART NUMBER 1. 708501 2. 708502 3. 708503-118 4. 708503-320 5. 708504 6. 708505 7. 708507 8. 708508 9. 708509 DESCRIPTION Rear Valve Housing Valve Spring Hydrant Body O-Ring Inner Valve O-Ring Operating Rod Hydrant Body Wedge Backplate Debris Cover Nut & Bolt Debris Cover Specify Size Specify Color Sold as assembly 10. 738501-116 11. 738502 12. 738503 13. 738504 14. 738505 15. 738506 Connector O-Rings Connector Body Check Valve O-Ring Check Valve Check Valve Spring Check Valve Retainer

Overview and Component Descriptions SHOWN: 12 HOUSE HYDRANT V1 in SLATE GRAY 1/2 NPT inlet (options available) Rear Valve Housing (unscrew counter-clockwise for maintenance) ASA Thermoplastic Debris Cover (replaceable, options available) Adjustable Friction Hinge Viton O-Rings Viton O-Rings 316L Stainless Steel (various stem lengths available) 5 Wedge (for automatic drainage) 3/4 GHT outlet (attach to any garden hose) Dupont Delrin Backflow Check Valve (use 1/2 hex to remove) A simple valve design ensures maximum reliabilty. There is only one moving part, the stainless steel inner rod that operates the rear closure. A spring holds the valve shut in the event of loss of pressure. Unscrew the rear valve housing to access the two internal Viton O-rings. The stainless steel operating rod and high-lifetime O-ring provide years of maintenance-free use. All of the wear and tear of daily use is moved to the highly durable Delrin hose connector. The abrasion-resistant polymer withstands thousands of cycles while preventing damage to the brass threads on your garden hoses. The rear valve housing can unscrew a full rotation from the hydrant body while remaining watertight. This allows alignment of the faceplate during installation. It also allows for different inlet configurations, such as 90 elbows. The debris cover features a 5 wedge to position the hydrant at a slight downward angle for drainage. We recommend installing with a PEX expansion loop inside the wall, to allow simple future maintenance from the exterior of the building. The Aquor hose connector, included with every hydrant kit, is designed to be used with any garden hose. Attach any splitter, inline vacuum breaker, or other accessory directly to the connector. If you need water access without a hose, or want to regulate flow pressure, use an Aquor Removable Faucet (CN-F) with your hydrant. Thread size: 3/4 GHT

Dimensions and Sizing 5 inlet: 1 2 NPT 37.2 mm (1 7 16 ) 88 mm (3 7 16 ) 30 mm (1 3 16 ) stem length (A) total hydrant length (B) Stem Total Interior wall clearance required: 4 6 8 10 12 149mm (5 7 8 ) 199mm (7 7 8 ) 249mm (9 7 8 ) 299mm (11 3 4 ) 349mm (13 3 4 ) HH004 HH006 HH008 HH010 HH012 Determine the correct House Hydrant length by using the chart above. Provide the desired stem size when ordering. Note the total end-to-end length and wall clearance needed is longer than the stem size. If you need a hydrant longer or shorter than the ones listed above, please contact us. Exterior entry hole: 38 mm (1.5 ) 72 mm (2.83 ) 79 mm (3.11 )

Configurations and Options List Hydrant Kits: HH004-B HH006-B HH008-B HH010-B HH012-B HH004-G HH006-G HH008-G HH010-G HH012-G 4 House Hydrant V1 - Aquor Blue 6 House Hydrant V1 - Aquor Blue 8 House Hydrant V1 - Aquor Blue 10 House Hydrant V1 - Aquor Blue 12 House Hydrant V1 - Aquor Blue 4 House Hydrant V1 - Slate Gray 6 House Hydrant V1 - Slate Gray 8 House Hydrant V1- Slate Gray 10 House Hydrant V1 - Slate Gray 12 House Hydrant V1 - Slate Gray Options: INL-90 CN-F CN-S1-B CN-S1-G 90 Elbow Inlet - 1/2 NPT Removable Faucet Add l Hose Connector - Aquor Blue Add l Hose Connector - Slate Gray