LED High-performance streetlight -afortable and reliable DESIGNED FOR FUNCTIONAL LIGHTING OF OUTDOOR ROADS WHERE ENERGY SAVING, LOW MAINTENANCE AND PRECISE LIGHT CONTROL CONSIDERATIONS ARE IMPORTANT FACTORS. APPLICATIONS Designed for lighting of major road including highways and parking lots. Outdoor lighting in Eco-friendly applications. FEATURES Designed to operate LED light sources of up to 450w HPS in an ambient temperature environment of up to 35 C, without reducing the LED lifetime of 15-25 years, at a lumen depreciation of not more than 20% (LM80). Marine Grade (LM6) high pressure die cast aluminum housing. No ingress of dust and moisture into the LED and controller compartment-ip66. OPTICAL SPECS. Optical analog design, different types of beam patterns and color temperature (3000k, 4000k 5000k, 5700k, 6500k) that can match different roads lighting system designs. Unsurpassed light uniformity. ENERGY SAVING 150W LED Street light is comparable 450W High pressure sodium lamp, energy saving up to 66%. ENVIRONMENT Working under harsh temperature: -40 C~+70 C. CONSTRUCTION Aerodynamic aesthetical design optimized for LED characteristics. Aesthetical and excellent heat dissipation design optimized for LED characteristics. Modular design for easily installation and maintenance. CERTIFICATION
UNIQUE ROAD SIMULATION DIAGRAM Main components parameters LED Effective high-power SEOUL LED (SZ5-M1). Available in white and outdoor white ( 3000K to 7000K CCT). Maximum drive current: up to 1500mA, we only use 700mA. Maximum junction temperature: 125 C Reflow solderable - JEDEC J- STD-020C compatible. Electrically neutral thermal path RoHS and REACH - compliant POWER DRIVER Universal AC input (90-305VAC) Working temperature: -40 C~+70 C. Power Protection: Short-circuits, overflowing, overvoltage, over-temperature. Built-in Active PFC. When the load >= 60%, PF>0.95. Efficacy up to 90.5%. IP67 / IP65 available, easy for indoors and outdoors installation. Output current can be adjusted through the output line control or internal potentiometer Natural cooling design. Apply to dry, damp, and rain environment. Good for LED lighting and LED display screen. Withstand 4kV surge level. (IEC61000-4-5). Safety standard: UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 complaint. ADDITIONAL OPTIONAL FEATURES * * * Color temperature: amber color Power driver: Meanwell HLG-/ CLG-/ L-Trend series. Surge Protection MCOV (Maximum continuous working voltage): 300VAC UP (Voltage protection): 1200V ( L-PE, N-PE, L-N ) IN (Nominal discharge current): 10kA * Maximum surge current: 20kA * SCCR (rated short circuit current): 5kA * Short circuit tolerance: 1.5kA * Response time:<25ns * Withstand: 1600VAC one minute
Product specification (Subject to change without notice) Item Number Power (watts) Dimension Pole base IP Grade Warranty LT-XXX-120-B 120W L445*W315*H85 Dia.45-60mm IP66 3 / 5 years LT-XXX-150-B 150W L530*W315*H85 Dia.45-60mm IP66 3 / 5 years LT-XXX-180-B 180W L530*W315*H85 Dia.45-60mm IP66 3 / 5 years LT-XXX-210-B 210W L615*W315*H85 Dia.45-60mm IP66 3 / 5 years LT-XXX-250-B 250W L615*W315*H85 Dia.45-60mm IP66 3 / 5 years Electrical and Technical Data (Subject to change without notice) Item Number Power (watt) Input Voltage View Angle PF LED Lumens 700mA Total Lumens CRI Color Temp. (Kelvin) LT-XXX-120-B 120W 100-277V C0/ 180 =140, C90/270 = 70 >0.95 140-150lm/w 16800-18000lm (measured value12000lm) min70 2600-7000 LT-XXX-150-B 150W 100-277V C0/ 180 =140, C90/270 = 70 >0.95 140-150lm/w 21000-22500lm (measured value15000lm) min70 2600-7000 LT-XXX-180-B 180W 100-277V C0/ 180 =140, C90/270 = 70 >0.95 140-150lm/w 25200-27000lm (measured value18000lm) min70 2600-7000 LT-XXX-210-B 210W 100-277V C0/ 180 =140, C90/270 = 70 >0.95 140-150lm/w 29400-31500lm (measured value21000lm) min70 2600-7000 LT-XXX-250-B 250W 100-277V C0/ 180 =140, C90/270 = 70 >0.95 140-150lm/w 35000-37500lm (measured value25000lm) min70 2600-7000 Shipping Data (Subject to change without notice) Item Number Net Weight Carton Dimensions (L x W x H) (mm) Qty. of Per Carton Per Carton Gross Weight Approx. Qty. of per 20 container (pcs.) Approx. Qty. of per 40 container (pcs.) LT-XXX-120-B 6kg 465 x 330 x 100 1pcs 7.5kg 1224pcs 2448pcs LT-XXX-150-B 7kg 550 x 330 x 100 1pcs 8.5kg 1152pcs 2304pcs LT-XXX-180-B 7kg 550 x 330 x 100 1pcs 8.5kg 1152pcs 2304pcs LT-XXX-210-B 8kg 640 x 340 x 100 1pcs 10kg 972pcs 1944pcs LT-XXX-250-B 8kg 640 x 340 x 100 1pcs 10kg 972pcs 1944pcs FEATURES: Pole Dimension: Φ60mm Arm adjustable turning angle. Adjustable turning angle for each module
ENERGY SAVING DATA (Energy Efficiency, Reducing carbon dioxide emissions) For 120W LED street light VS. 250W HPSL at 5000K CCT Estimated Lighting Costs Using a 310W power consumption HPSL Total Estimated Annual Savings = $ 6270 Reducing carbon dioxide emissions: 310 W 3,000 hrs 930,000 watt-hours = 1,000 = 930 kwh per year x kwh rate of $0.11 = $ 102.3 per year x 100 lamps per space = $ 10,230 annual energy cost per space Estimated Lighting Costs Using a 120W LED street light 120 W 3,000 hrs = 360,000 watt-hours 1,000 = 360 kwh per year x kwh rate of $0.11 = $ 39.6 per year x 100 lamps per space = $ 3,960 annual energy cost per space 49 ton CO2 /year Notice: Above data is based on same illumination between High Pressure Sodium Light and LED Street Light. Energy saving rate: 61.3% In view of high CRI of LED street light, as a matter of fact, 310W HPLS could be replaced entirely by our 80W LED street light. In that case, the energy saving rate should be 74%. This energy saving example shows an application of 100 HPSL in a space currently using 100 traditional HPSL 310W, operating 3,000 hours per year at a cost of $0.11 per kwh. Your actual savings may vary depending on the energy costs in your geographic location. Replacing 100 traditional 310W HPSL with the 120W LED street light can provide significant energy costs savings of $6270 per year! Potential savings from the reduction savings from the reduction in HVAC costs as a result of using a lower wattage bulb that emits less heat is an additional benefit not included in this example. For 150W LED street light VS. 400W HPSL at 5000K CCT. Estimated Lighting Costs Using a 450W HPSL 450 3,000 = 1,350,000 1,000 = 1,350 x kwh rate of $0.11 = $ 148.5 x 100 lamps per space = $ 14,850 W hrs watt-hours kwh per year per year annual energy cost per space Estimated Lighting Costs Using a 150W LED street light = 1,000 = x kwh rate of $0.11 = x 100 lamps per space = 150 W 3,000 hrs 450,000 watt-hours 450 $ 49.5 $ 4,950 Total Estimated Annual Savings = $ 9900 kwh per year per year annual energy cost per space Energy saving rate: 66.67% Reducing carbon dioxide emissions: 78 ton CO2 /year Notice: Above data is based on same illumination between High Pressure Sodium Light and LED Street Light. This energy saving example shows an application of 100 HPSL in a space currently using 100 traditional HPSL 450W, operating 3,000 hours per year at a cost of $0.11 per kwh. Your actual savings may vary depending on the energy costs in your geographic location. Replacing 100 traditional 450W HPSL with the 150W LED street light can provide significant energy costs savings of $9900 per year! Potential savings from the reduction savings from the reduction in HVAC costs as a result of using a lower wattage bulb that emits less heat is an additional benefit not included in this example.
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS WARNING: THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 1. Risk of fire or electric shock..the electrical rating of these products are 100~277V, the installer must determine whether they have 100~277V at the luminaire before installation. 2. Risk of fire or electric shock. Installation requires knowledge of fluorescent lighting luminaires, electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. 3. Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. 4. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. 5. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation DANGER-RISK OF SHOCK-DISCONNECT POWER BEFORE INSTALLATION. CAUTIONS: 1. Suitable for dry and damp locations. 2. Not for use in totally enclosed luminaires. o 3. This device is not intended or f use with emergency exit fixtures or emergency lights. 4. Before replacing, turn off ower p and let lamp cool to avoid electrical shock or burn. 5. Risk of electric shock. Do ot n use where directly exposed to water. 6. This device is not intended or f use with emergency exits. 7. Lamps must be operated wi thin an ambient fixture temperature of -13F (-25c) and 140F (60c) co comply with all safety and w arranty regulations. : : Light and Energy International, LLC, P.O. Box 51960, Sparks, NV 89434 USA Tel: (775) 351-3000 FAX: (775) 351-3001 www.leilighting.com