GENO -MX 1" - MX DN 100 backwash filter. Intended use. Scope of supply. Function. Structure

Similar documents
HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet

We understand water. Residential Applications Sanitary and Heating. General Catalogue

PRODUCT OVERVIEW FINE FILTER AND BACKFLOW PREVENTER

3/2-way Solenoid Valve for pneumatics

Examples 3/2-way valve A T NO: Symbol

Profluid and Gap-type tube filters. Automatic filters

Filtomat M100/MG Filters

Automatic filter AF 172 G

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Automatic filter AF 173 G

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

Check List for Optimal Filter Performance

Hydrants. Tab 2, page 1

2018 High Performance Check Valves for liquid and gaseous media

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

SELF-CLEANING FILTER

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Company Standard Mounting Instructions for Type Valves with Type AT Actuator

Duplex Filter Pi Features. Nominal pressure 10/16 bar (140/230 psi), nominal size 1250 up to 8000

Automatic back-flushing filter AutoFilt RF4

High Pressure Filter Pi 4000

GL Ludemann Y-Strainers

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Process Inline Filter Medium / High Pressure PFM / PFH

2/2-way proportional seat valve

High Pressure Filter Pi 4230

Tank top return-line filter Pi 5000

The JET Filter. Scope of Delivery. patented. The New Definition of Purity for Your Medium. Our Filter Systems Protect

Automatic filter AF 173 G

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve

Filtration and separation technology. Lenzing OptiFil Automatic backwash filter

To ensure proper installation, digital pictures with contact information to before startup.

Automatic filter AF 153 G

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

Introduction. Operation FTG 600

CONA Further components / Accessories

Filter Type PR-BW 100. Filtration

Automatic filter AF 113 G

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

BIOVENT. Hygienic Valve

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

VERTICAL IN-LINE PUMP

Automatic filter AF 112 G

The JET Filter. Scope of Delivery. patented. The New Definition of Purity for Your Medium. Our Filter Systems Protect

Automatic metal-edge filter AF 73 G/AF 93 G

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

CONA ANSI Further components / Accessories

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Manual for 12 Sand Filter/ Pump Combo Unit.

Process screen basket filter PRFS

2/2-way Solenoid Valve for liquids and gases

APP pump instruction APP and APP 16-22

Mounting and Operating Instructions EB 5868/5869 EN

Rotary Displacement Meter DKZ 02

Process Inline Filter PLF1

Backflushing Filter AutoFilt RF3

Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection

Pressure relief controller V22 D28

High Pressure Filter Pi 4230

APP pump instruction APP 21-43

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

Starting up hydraulic systems

ALLWEILER. Block Macerators Series ABM Designs S and I. Design I with controller and seal water unit

Line filter with filter element according to DIN 24550

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Medium Pressure Filter Pi 3000

Duplex Filter Pi 3700

Introduction Advantages of cooperating with Our service - our conditions Our standard central control valve

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Change-Over Inline Filter RFLD Welded Version

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Medium Pressure Filter Pi 340

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

ARI-STEVI 440 / 441 DVGW type approval

Liquid ring vacuum pumps with magnetic coupling

Remote Process Actuation Control System AirLINE - Siemens ET 200S

2/2-way Solenoid Valve with servo diaphragm

Page 6. Page 6. Page 6. Page 7. Page 8. Page 9. Page 10 / 11

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

High Pressure Filter Pi 420

Installation, User and Service Manual. Filter Unit WP1-B2-200

BWT Infinity A DIN 20mm.972 L/s DIN 25mm L/s DIN 32mm L/s

Industrial automatic self-cleaning filters made in stainless steel AISI 316

Servo-operated 2/2-way solenoid valves Type EV220A

Filtration Ft-Line 34. Ck-Line 38. Cp-Series 42. FilterMax 46. Cintropur filtration 51. Cartridge housings

Air Filtration CLEARPOINT. energy saving compressed air filtration. Truth in Compressed Air.

HAWLE-AIR RELEASE VALVES

AUTOMATIC AIR VALVES For potable water

Make sure that no hazardous fumes can build up in the piping and in the meter during commissioning, decommissioning and dismantling.

Oil Filter Module Pi 8300

Si Engineering GREAT Solutions. Process and steam safety valves to PED and DIN/EN standards

Inline filter with filter element according to Bosch Rexroth standard. Type 16 FE Features. Contents

Backflushing Filter AutoFilt RF4

Automatic filter AF 113 G

Transcription:

Subject to modifications TD2-AM001en_004 Edition June 2017 GENO -MX 1" - MX DN 100 backwash filter Intended use The GENO -MXA backwash filters are suitable for the following sectors: Filtration of drinking water Filtration of industrial water Overpressure The filters are not suitable for the following sectors: Filtration of circulation water treated with chemicals Filtration of oils, greases, solvents, soaps and other lubricating media Separation of water-soluble substances Negative pressure Function Filtration The unfiltered raw water flows into the filter from the inlet side and then passes through the filter element to the pure water outlet. Foreign particles the size of > 50 μm, 100 μm, 200 μm, 500 μm - depending on the filter element - are thus retained in the filtration process. Depending on size and weight, the foreign particles either stick to the filter element or fall straight down where they accumulate at the lowest point of the filter. Backwash Manual and time-controlled backwash. The pressure of the filtered pure water is used for the backwash. Triggering the backwash causes several things to happen: Brushes on the raw water side remove foreign particles from the filter elements. A suction nozzle opens the drain outlet at the bottom of the filter towards the backwash water connection. The pressure of the pure water is higher than the atmospheric pressure at the backwash water connection. Due to this differential pressure, a part of the pure water flows through the filter elements within the area of the hollow brushes into the suction nozzle. This part of the pure water is used as rinsing water. The rinsing water flushes the disslolved foreign particles through the suction nozzle. The rinsing water leaves the filter at the drain outlet towards the backwash water connection after passing through the suction nozzle. At the end of the backwash, the drain outlet will be closed. Structure All parts coming into contact with the medium are made brass with a low level of dezincification or high-grade industrial plastic. Modular filter element made of high-grade, industrial plastic with filter mesh made of stainless steel. Integrated backwash water connection (funnel) according to DIN EN 1717. Pressure gauge on raw and pure water side to determine the degree of impurities (differential pressure). Water meter screw connection on GENO -MXA 1" - MXA 2" backwash filter. Flange connection on GENO -MXA DN 65, MXA DN 80, MXA DN 100 backwash filter (dimension of flange connection acc. to DIN 2642, without counterflanges and seals). All water-contacting parts meet the requirements of the German Food and Feed Act (LFGB). Scope of supply Backwash filter complete, including 2 pressure gauges 0-16 bar. Up to a nominal diameter of DN 50 with water meter screw connections. Starting from a nominal diameter of DN 65, flange version. Counter flanges and seals are not included in the scope of supply. 1 7

Technical specifications I Pressure loss curves of GENO MX / MXA 1" and 1¼" backwash filters 1 Differential pressure in bar 2 Flow rate in m 3 /h 2 7

Technical specifications II Pressure loss curves of GENO MX / MXA 1½" and 2" backwash filters 1 Differential pressure in bar 2 Flow rate in m 3 /h 3 7

Technical specifications III Pressure loss curves of GENO MX / MXA DN 65, DN 80 and DN 100 backwash filters 1 Differential pressure in bar 2 Flow rate in m 3 /h 4 7

Technical specifications IV GENO MXA backwash filter Connection diameter 1" 1¼" 1½" 2" Nominal connection DN 65 DN 80 DN 100 diameter Order no. 107 450 107 455 107 460 107 465 107 470 107 475 107 480 Dimensions and weights A: Installation length without screw connection B: Installation length with screw connection B: Installation length without counter flanges Flanges PN 16 acc. to DIN [mm] 190 190 206 206 - - - [mm] 276 281 342 323 - - - [mm] - - - - 220 250 250 C: Min. distance to wall [mm] 115 115 115 115 115 125 125 D: Overall height above centre of connection E: Overall height from lower edge of filter to centre of connection [mm] 153 153 233 233 233 243 243 [mm] 194 194 212 212 212 302 302 F: Total height [mm] 347 347 445 445 445 545 545 G: Space above upper edge of filter H: Space required for replacing filter element I: Bolt circle diameter of flange [mm] 130 [mm] 100 100 minimum 100 optimum from 215 minimum 100 optimum from 315 [mm] - - - - 145 160 180 J: Max. sealing surface [mm] - - - - 122 140 158 K: Number of M 16 screws [pcs] - - - - 4 8 8 Length of cable for differential pressure transducer [mm] 1500 Length of cable for drive unit [mm] 1500 Length of mains cable [mm] 1500 5 7

Dimensions and weights Empty weight with control unit GENO -RS-tronic approx. [kg] 8.6 8.7 12.7 12.7 14.8 19 20 Technical specifications V GENO MXA backwash filter Connection diameter 1" 1¼" 1½" 2" Nominal connection diameter DN 65 DN 80 DN 100 Order no. 107 400 107 405 107 410 107 415 107 420 107 425 107 430 Connection data Drain connection HT pipe DN 50 Power supply [V]/[Hz] 230/50-60 Operation with protective low voltage 24V~ Electrical power consumption data Operation = max./standby [VA] 26/19 Protection / protection class IP54/ Performance data Flow rate at p 0.2 (0.5) bar [m 3 /h] 8.5(13) 12(18.5) 22(30) 27(38.5) 30(47) 60(96.5) 60(98) KV-value [m 3 /h] 18 25 46 56 69 124 138 Pore size [µm] 100 Largest/smallest pore size according to DIN EN 13443 [µm] 110/90 Nominal pressure PN 16 Minimum flow pressure [bar] 2 Operating pressure at max. water temperature [bar/ C] 10/90 Differential pressure release [bar] 0.4 0.5 Consumption data Backwash water volume at a water pressure of 3 bar and a backwash time of 1.5 min., approx. Max. backwash volume flow at 9 bar, approx. [l] 40 [m 3 /h] 4 General DVGW registration number NW-9301BO0194 Max. water temperature [ C] 90 Max. ambient temperature [ C] 40 6 7

Installation example 1 2 3 1 Water meter 3 Shut-off valve 2 2 Shut-off valve 1 Requirements with regard to the installation site Observe local installation directives, general guidelines and technical specifications. Requirements on the electrical wiring Push socket with earthing contact within approx. 1.2 m of the control unit Requirements with regard to the water connection Drain water connection DN 50 to discharge the rinsing water Floor drain or a corresponding safety device Install the product where it is not exposed to: Strong heat Frost Direct sunlight Chemicals, dyes, solvents and their vapours Negative pressure Coarse impurities. In case of coarse impurities, install a coarse dirt filter upstream of the inlet. Spare parts Please inquire. Accessories Safety valve for MXA Solenoid valve closed when deenergised Controlled by the GENO -RS-tronic Pre-assembled on the backwash water outlet, the safety valve prevents unacceptable water leaks during backwash in the event of a power failure. Please inquire. Contact Grünbeck Wasseraufbereitung GmbH Josef-Grünbeck-Strasse 1 89420 Hoechstaedt/Germany +49 9074 41-0 +49 9074 41-100 info@gruenbeck.com www.gruenbeck.com 7 7