Before using the new measuring rod, please take a little time to read the following safety instructions.

Similar documents
seca 769 D GB F I E P

Before using the new scale, please take a little time to read the following safety instructions.

seca 954 D GB F I E Instruction manual and guarantee

Full certification ISO 9001 ISO Model GB

HRS305. Hand Rail Scale

HM 200/201/210D Height Measurement USER MANUAL Please keep the instruction manual at hand all the time for future reference.

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used.

seca 874 Instructions for Use

Weighing Indicator TM701 Handrail scales

Compact Scales. Software Revision V1.25 & above

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

User Guide. Digital Shipping Scale S150

3 YEAR WARRANTY USER GUIDE BATHROOM SCALE BATHROOM. 148 mm 148 mm. 210 mm AFTER SALES SUPPORT MODEL: 91389, 07/2014 CN KW / / / / / /

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

Meter FMT II. Operating manual. original operating manual. Translation of the

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

Operating instructions Platform/floor scales

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

original operating manual Operating manual Manual flow meter FMOGne Translation of the Item-No.: ,

FHT 8V Wireless Actuator

Operation Instructions

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

SPC Series. Digital Scale. Operation Manual

Thermometer models / 00831A

LHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1

User s Manual. Captain Bear s Bathtime VTech Printed in China UK

ELECTRICAL. Laser Distance Measure User Guide

INSTALLATION INSTRUCTIONS

Operating instructions ErgoPack 600 E

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

SAFETY AND CERTIFICATIONS

Wireless Thermometer model 00380

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

K1013 K1013. Fitting Instructions for Basic Carrier. x 4 x 4 x 1 x 8. x 4 x 1 x 4 x 1. x 4 x 1 x 1 x 2. Revision No: 1A 1

Thermometer model 00826

Swedish Code of Statutes

Mechanical Physician Scale Installation & Operation Instructions PN

Xenon Fiberoptic Lightsource

Humidity Monitor model 00619

Operation Instructions

Operating Instructions. bluesmart Active

SIXTH PART BATTERIES AND ACCUMULATORS. 48a Basic provisions and definitions

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

i n s t r u c t i o n m a n u a l

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter

As with any piece of fitness equipment, consult a physician before beginning your E820 exercise program.

ELECTRICAL. Moisture Meter User Guide

INSTRUCTION MANUAL SPECIFICATIONS:

freedom through lightweight solutions

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

Easy-On Wireless Tail Lights User s Guide

Garden Thermometer with Solar Lighting

Thermometer models 02023/02028/02053/02054

freedom through lightweight solutions

Window Thermometer models / / 00423

DIGITAL TORQUE GAUGE MODEL BTGE-G

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

Chek-A-Cell TM. Instruction Manual Rev A 8/12

AquaLift Bath Lift System MODEL #8100

Section R Scales & Height Measures Medically Approved

FOR YOUR PERMANENT FILE

Archimedes. user instructions. Simple solutions for everyday independence

Thermometer models 02023, 02028, 02029

Wireless doorbell transmitter FS20 TK

FOR YOUR PERMANENT FILE

Mangar Archimedes Instruction & Safety Manual

ACE. DOUBLE DOOR QUADRANT Installation and User Guide. These instructions must be left with the user W2-E

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

Installation instructions for the TriVision Car Docking Station

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

##CFG BWOP Manuals## Quasar elite HD-LED Mobile Models Assembly Guide

Digital Clock model 75100C

Adam Equipment. CB Balance. (P.N Revision B1, Apr 2014)

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

K327. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 4. Revision No: 5E 1

To ensure correct operation and service please read these instructions before installing and operating the TPMS P451 TPMS Manual TABLE OF CONTENTS

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

GB C10WL. English page 1-18 D C10WL F C10WL I C10WL E C10WL NL C10WL. Deutsch Seite Français page Italiano pagine 57-74

Intelligent Battery Charger

Instructions for Use. Amfibi Hygiene chair. Amfibi Double HighBack

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

IMC. Battery Charger. Instruction Manual

Operating Instructions Precision balance

IN & TM Series User Manual

RoughDeck TM FXB Flexure Base Floor Scale. Installation/Operation Manual

K1022. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 8 x 1. x 4 x 4 x 1 x 4. x 8 x 4. Revision No: 2B 1

CONTACTS EGR VALVE TESTER 66248

MOISTURE METER 2155 OPERATION INSTRUCTIONS VERSION 1.0

NCSA 20plus Service Manual

Classic Instruments. Installation Manual

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Wireless Thermometer model 00782W

Transcription:

1. Congratulations! In the seca 242/seca 245 electronic measuring rod, you have acquired a highly accurate and simultaneously sturdy piece of equipment. seca has been putting its experience at the service of health for over 150 years and as market leader in many countries of the world, is always setting new standards with its innovative developments in weighing and measuring. seca 242/seca 245 measuring rods are used for diagnosis and treatment in hospitals and doctors surgeries. The display unit is separate from the slide unit. The value determined is transmitted by radio. Power is provided exclusively by batteries and there are no annoying cables. 2. Safety The seca 242 measuring rod is fixed directly to the wall you can define the height at which it is fixed, and thus the measuring range, yourself. The seca 245 measuring rod is supplied with a statometer. This can be moved on castors, allowing it to be used on a mobile basis. The height displayed can be switched between centimetres (cm) and inches (ins). On both models, the current value can be specified as a temporary zero point, allowing relative measurements of extremities, for example, to be made. The measuring rod is of a very sturdy construction, and will give you long and reliable service. Before using the new measuring rod, please take a little time to read the following safety instructions. Follow the instructions in the instruction seca 245 only: ensure that the patient manual. does not lean against the measuring rod You must not drop the measuring rod or risk of falling! display housing nor subject them to violent shocks. thorised persons. Have repairs performed solely by au- After measuring height, push the slide unit back up risk of injury! Model 242/245 GB 17

3. Before you really start Unpacking Remove the packaging. The scope of supply includes: seca 242 measuring rod, bottom part measuring rod, top part, with head stop heel plate display unit desk-top stand wall bracket 5 mounting screws 5 rawlplugs 20 spacers 2 cylindrical bolts (plastic) and nuts 1 bag containing a pan-head tapping screw 10 AA 1.5 V batteries 1 instruction manual seca 245 measuring rod, bottom part, premounted to column measuring rod, top part, with head stop statometer platform display unit desk-top stand wall bracket 2 mounting screws 1 bag containing a pan-head tapping screw 10 AA 1.5 V batteries 1 instruction manual 18

Assembly seca 242 Select a location for attaching the measuring rod where the floor is level and unyielding. In order to avoid damage to the measuring rod during use, the heel plate must be supported against the wall. The number of spacers used determines the distance of the measuring rod from the wall. You need to use at least one spacer for each of the two mounting points. Place the spacers on top of one another and screw them to the heel plate using the plastic nuts and bolts. Alternatively Mark drill holes for the heel plate. Drill using a 5 mm drill bit. Push the rawlplugs supplied into the holes. Mount the heel plate and the spacers using two screws. Remove the cable tie (provided for transport purposes) on the top measuring rod. Push the top measuring rod onto the plastic guide of the bottom measuring rod and screw it tight using the panhead tapping screw. Place the bottom measuring rod on the heel plate and hold the measuring rod up to the desired point of attachment. Use a spirit level to align it in the perpendicular. Mark the drill hole for the measuring rod. Drill using a 5 mm drill bit. Push the rawlplug into the hole. Push the bottom measuring rod onto the heel plate. Put the spacers between the measuring rod and the wall and fix the measuring rod in position. 2. 3. 1. Model 242/245 GB 19

seca 245 Put the column in the opening. Screw the column to the platform from underneath. If necessary, place the platform carefully on its side to tighten up the screws. Then stand the column and the platform upright again. Remove the cable tie (provided for transport purposes) on the top measuring rod. Push the top measuring rod onto the plastic guide of the bottom measuring rod and screw it tight with the panhead tapping screw. Positioning the display housing There are various options for setting up the display housing. On a desk top Place the display housing flat on a desk top. Using the desk-top stand Place the desk-top stand on the display housing from underneath. The broad side should be at the top of the display. The desk-top stand engages. Place the display housing on a desk top. On the wall Fit the wall bracket to the wall at the desired height. Push the housing display onto the wall bracket. 20

With wall bracket and desk-top stand Place the desk-top stand on the display housing from underneath. The narrow side should be at the top of the display. The desk-top stand engages. Fit the wall bracket to the wall at the desired height. Push the display housing onto the wall bracket. Inserting batteries Pull out the battery drawer on the display unit. Insert four batteries. Ensure polarity is correct. Push the drawer back in. Take the cover off the battery compartment of the slide unit. Take out the battery pack and insert 6 batteries. Ensure polarity is correct. Insert the battery pack in the battery compartment and close the cover. Model 242/245 GB 21

4. Operation Controls and displays Calibration (seca 242 only) Calibration is required only if the bottom end of the measuring rod is not exactly on the standing surface. The drill may have slipped during mounting or you may deliberately have selected a different fixing height to vary the measuring range. Calibration need only be performed once. Keep the ZERO key depressed and then switch on the display housing by pressing the START key. A flashing number appears this is the calibration counter. Release the ZERO key and then press it again for at least 1.5 seconds. Put a metre stick or other known measure underneath the head stop. Compare the value displayed with the actual value. They should match. 22

In order to change the value displayed so that it agrees with the actual value, proceed as follows: press the cm/ins key to increase the value in 0.5 mm increments. If you also press the ZERO key, the value changes rapidly. Press the ZERO key to reduce the value in 0.5 mm increments. If you also press the cm/ins key, the value changes rapidly. Complete the calibration process by keeping the ZERO key depressed for at least 5 seconds. The internal calibration counter is increased by 1. The measuring rod switches off. Measuring height Press the START key on the display housing. ----- is displayed initially. The last unit selected before the rod was switched off is active and marked with an arrow. If necessary, switch the unit in which height is measured (see page 24). Push the head stop far enough up the rod so that the person to be measured can stand underneath it comfortably. Ask the person to be measured to stand with his or her back to the measuring rod. Heels should be against the plate and the back and head straight. Now slide the head stop down until it touches the head. Read off the height measured on the display unit. For information on transferring the result to a connected scale, see page 26. Model 242/245 GB 23

Switching unit of height The display can be switched between centimetres (cm) and inches (ins). Switch on the measuring rod. Display will initially be in the last setting selected. To switch the display, press the cm/ins key. An arrow lights up next to the cm or ins display. Relative measurements The measuring rod can be set to zero at any desired position. This function allows relative measurements to be made and is used when measuring extremities, for example. Press the ZERO key to zero the measuring rod at the current position. ZERO SET is marked in the display. All lengths are now measured relative to this new zero point. If the zero point is not reached, the measured values shown are preceded by a minus sign. Press the ZERO key again when you want to display absolute length once more. 24

Switching off the measuring rod To switch off the measuring rod, press the START key again. If the measuring rod is no longer being used, it switches off automatically after 5 minutes. After measuring, push the head stop back up to prevent injuries occurring. Selecting a channel if you have two measuring rods To operate two measuring rods simultaneously in the same reception area, the channel for radio transmission on the display unit and the slide unit can be switched. For transmission to function, the channels on the display unit and the slide unit must match. Channel B is always selected when the measuring rod is delivered. To switch the channel, proceed as follows: Move the slide unit. Keep the DATA VALID key depressed for at least 5 seconds. The module is switched to the other channel. Keep the cm/ins key on the display unit depressed and switch it on. The channel of the display unit is switched. The active channel is displayed for 2 seconds (e.g. CH B). Note: it may be necessary to re-set the channel after the batteries in the slide unit have been changed. Your measuring rod is mobile (seca 245 only) It has two castors at the back. For mobile use, the seca 245 can be tilted slightly backwards and then moved on its castors. Model 242/245 GB 25

Connecting to a scale There is a serial interface in the display housing which allows the measuring rod to be connected to a scale. The scale is then able to add information about height and weight to other characteristic data. The interface cable required is available as an accessory. Use the interface cable to connect the scale to the RS 232 interface on the underside of the display housing. The current value is transmitted to the scale when the DATA VALID key on the display housing or on the head stop is pressed. Detailed information can be obtained from seca Customer Service. 5. Cleaning and care Clean the measuring rod and the outside of the display housing as required using a domestic cleaning agent or commercially-available disinfectant. Follow the manufacturer s instructions. Under no circumstances use abrasive or acid cleaners, spirit, benzene or the like for cleaning. Such substances can damage the high-quality surfaces and coding. 6. What do I do if... no display appears? Is the display housing switched on? Check whether batteries have been inserted in both the measuring rod and the display housing. Ensure polarity is correct! one segment comes on permanently or not at all? The segment in question is defective. Contact Servicing. display ----- appears? The display unit has been switched on, but the head stop has not yet been moved. Check that channels match. 26

battery symbol appears in the display? The battery charge in the display unit is low. You should replace the batteries in the next few days. display appears? The batteries in the slide unit are dead display appears? The slide unit is adjusting to new illumination/installation conditions. This happens when new batteries have been put in. If this message does not disappear within 2 minutes, even when the slide unit has been moved, inform Servicing. display Er:5:62 appears? Inform Servicing. display appears? The display unit is awaiting data from the head stop, but is no longer within transmission range or transmission is subject to interference. Make sure you observe the range of approx. 10 m. display appears? The slide unit cannot evaluate the code. Push the slide unit a little and check whether the coding is clean. Avoid especially strong light sources acting on the sensor unit. If these measures do not lead to the display disappearing, inform seca Servicing. display Er:5:66 appears? Check whether there are any sources of radio interference in the vicinity. Eliminate these and then start the measuring rod again. If the fault is still being displayed, inform Servicing. the slide unit slips down? Tighten up the screw on the slide unit using a small screwdriver. Model 242/245 GB 27

7. Servicing Depending on frequency of use, we recommend servicing at intervals of between 3 and 5 years. Please ensure that a qualified servicing organisation is used for this - seca Customer Service will help if you are in doubt. 8. Technical data seca 242 seca 245 Dimensions Width: 300 mm 310 mm Depth: 250 mm 400 mm Height: 2200 mm 2276 mm Weight approx. 2,5 kg approx. 7,8 kg Accuracy ± 2 mm Reproducibility ± 1 mm Measuring range 62 210 cm 62 214 cm 25 82,6 ins 25 84,2 ins Graduations 1 mm / 0,05 ins Operating temperature +10 to +40 C Storage temperature -20 to +60 C Range for radio transmission 10 m Size of figures in display unit 9. Disposal Disposing of the measuring rod and the statometer Should the measuring rod or the statometer no longer be able to be used, the responsible waste disposal association will be glad to provide you with information about the measures necessary to dispose of them properly. 20 mm Batteries Do not dispose of empty batteries in domestic waste. You are legally obliged to hand in used batteries/rechargeable batteries to a local collection point so that they can be disposed of in an environmentally-friendly way. When buying new batteries, select batteries low in harmful substances and containing no mercury (Hg), cadmium (Cd) or lead (Pb). 28

10. Warranty A two-year warranty from date of delivery applies to defects attributable to poor materials or workmanship. All moveable parts - batteries, cables, mains units, rechargeable batteries etc. - are excluded. Defects which come under warranty will be made good for the customer at no charge on production of the receipt. No further claims can be entertained. The costs of transport in both directions will be borne by the customer should the equipment be located anywhere other than the customer s premises. In the event of transport damage, claims under warranty can be honoured only if the complete original packaging was used for any transport and the scale secured and attached in that packaging just as it was when originally packed. All the packaging should therefore be retained. A claim under warranty will not be honoured if the equipment is opened by persons not expressly authorised by seca to do so. We would ask our customers abroad to contact their local sales agent in the event of a warranty matter. Model 242/245 GB 29