OptiFuel. solid partners proven solutions. Precision and portability in a top of the line FTIR Fuel Analyzer

Similar documents
OptiFuel. solid partners proven solutions. Precision and portability in a top of the line FTIR Fuel Analyzer

VERSATILITY IN PROCESS CONTROL & FUEL ANALYSIS USING ATR FLOW CELL & FT-IR. Michael Collier 19-January-2018

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

IROX 2000 IROX DIESEL

ANNEX 2, REFERENCE FUELS

ANNEX 3 REFERENCE FUELS. Parameter Unit Limits (1) Test method Minimum Maximum Research octane number, RON

Multi-Parameter Certified Reference Material

CERTIFICATE OF ACCREDITATION

Stabinger Viscometer SVM 3001

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Determining the Ethanol Content of Denatured Fuel Ethanol Using Near Infrared. Gulf Coast Conference Patrick Ritz PAC LP

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Table of Contents. Copyright and Trademarks 5. Copyright 5 Revision 5 Disclaimer of Liability 5 Copy and Use Restrictions 5.

ERAVAP NEW! VAPOR PRESSURE TESTING AT ITS BEST. One Vapor Pressure Tester for All Applications:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Economic and Social Council

MB3000. Versatile FT-IR analyzer designed for your industry The most reliable FT-IR, the lowest cost of ownership.

Vapor Pressure Measurement Of Gasoline, Crude Oil & LPG With New ASTM D5191 & D5188 Speed Test

On-Line NIR Analysis for Blending

MiniLab EL Series for High Performance Engine Development and Maintenance

Low cost EDXRF elemental analyzer

International Quality Assurance Exchange Program Schedule. Fuel Month Number Type Dispatch Date Closing Date

ADU 5. Automatic Distillation Unit

The Advantage of Real Atmospheric Distillation using D7345 Test Method. Presented by Jonathan Cole, PAC

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

Sulfur in Oil Analyzer

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Advantages of Using Raman. Spectroscopy to Monitor Key. Gasoline Blending Parameters

Exceeding Expectations

AC Reformulyzer M3. 75 Minutes Full Gasoline Analysis. Compliance with ASTM D 6839, EN and ISO Self Explanatory Operation

A Balanced Approach to Octane Replacement

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

Elemental Analysis Advanced

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Stabinger Viscometer Series. SVM Series

एमआरप एल ग णव नय ण य गश ल उप दन व श:२०१७ MRPL QC LABORATORY

FORLINE LTD. Global Energy Solutions Kenneth Pike, Suite 200B Greenville, Delaware, 19807, USA. 19 Kathleen Road, SW11 2JR, London, England

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

LABORATORY. Fuel additives technology.

PRODUCT OVERVIEW HOSKIN SCIENTIFIC LTD. Vancouver Burlington Montreal

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

National Oil Corporation Libyan Petroleum Institute. Crude oil assay Sarir crude oil

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Ceiba Crude (31.44 API, Sul WT%)

Refinery and Natural Gas Analysis

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

Commercial installations : BP Lavera steam cracker, France, BP Grangemouth (UK), COPENE Camaçari (Brazil) and a number of undisclosed plants.

Application. Gas Chromatography June 1995

National Oil Corporation Libyan Petroleum Institute. Crude Oil Assay Messla Crude Oil

ASTM Aviation (Turbine) Jet Fuel Sample ID: JF1211

Ethanol and the Economics of Octane The Superior Solution

Heartland Pipeline. Heartland Pipeline Company Product Specifications. Effective Date: 10/1/2015

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Specifications Of Straight Run Naphtha for Exportation

PROVISIONAL SCOPES. o C, API Gravity, Light Ends, Mercury, Pour Point, Salt, Sediment (D473 and D4807), Sulfur, Viscosity and Water.

MiniLab EL Series for High Performance Engine Development and Maintenance

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

Monitor Chlorine in Crude at Sub-ppm Levels

SELLING GTL SOME OBSERVATIONS ON THE MARKETING OF GTL PRODUCTS

Instruments for the Analysis of Petroleum Products. Oxidation Stability

White Paper.

Annex no. 1 of Accreditation Certificate no. LI 333 from

D-2 Incorporated. JF-1A-RC RampCheck Product Brochure. Part Number: JF-1A-RC Revision Date: 09/11/15 Drawing Number: R6

Phase Technology PPA-70Xi Pour Point Analyzer

On-Line Process Analyzers: Potential Uses and Applications

PRICE LIST 2017/2018

X-ray Essentials from XOS Proven Performance

EAST AFRICAN STANDARD. Automotive gasoline (premium motor spirit) Specification EAST AFRICAN COMMUNITY. HS (regular); HS

Cetane ID 510. Customer Presentation. Refining. Petrochemical

M. Pospíšil, Z. Mužíková, G. Šebor Svojstva...

Economic and Social Council

COOPER BASIN CRUDE OIL. Santos Limited

CERTIFICATE OF ACCREDITATION

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

Sweeny to Pasadena Pipeline

Phillips 66 Carrier LLC. Borger-Amarillo Pipeline (BAM) Product Specifications

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

GC Method Compliance and Large Valve Oven Application

Tung Xiao Dan Assistant Chemist Mark Tan Section Head Feedstock Evaluation Department

ElvaX Sulfur in Oil analyzer

SPECTRO XRF Report. SPECTRO iq II

Callisto 100. Cold Filter Plugging Point Tester

On-Line NIR Analysis of Crude Distillation Unit

State-of-the-art viscosity monitoring

A new simple and robust process FT-NIR Spectrometer with small footprint and extended maintenance interval

TSHR 6000 series TN/TS/TX analyzer

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Phillips Texas Pipeline Company, LTD. Amarillo-Lubbock Pipeline (SAAL) Product Specifications

VEHICLE AND ENGINE TESTING SERVICES FOR RESEARCH, DEVELOPMENT AND CERTIFICATION

Optimization of Motor Gasoline Production

MEASURE. BIOFUEL PARAMETERS When and Where You Need To. Coen Duvekot Product Marketing Manager, MicroGC

Physical Property Analyzer PPA4100 Series. On-Line RVP Analyzer

ALL TESTS. Density Oscillating U-tube method * IP 365. Distillation characteristics of petroleum products - Micro distillation method IP 596

Transcription:

solid partners proven solutions 10-year optics 2-year system WARRANTY 5-year light source OptiFuel Precision and portability in a top of the line FTIR Fuel Analyzer Superior performance and ruggedness Expert service and support worldwide Unmatched warranty on critical components WWW.PACLP.COM

OptiFuel ACCURATE, EASY AND RELIABLE FUEL ANALYSIS For more than 20 years, PAC has been at the forefront of infrared (IR) fuel analysis with its PetroSpec products. Now we are combining the best of our GS PPA, TD PPA and QuickSpec capabilities into one analyzer and adding the latest FTIR technology into the most robust fuel analyzer in the market. The user-friendly system allows the operator to measure many properties at once with a simple touch of a button, using free factory calibration models. Users can customize the models with local samples in a few seconds. These custom models can easily be cloned to all your OptiFuels, even remotely, if necessary. GLOBAL SUPPORT Extensive support network through our offices and over 140 distributors worldwide. ISO-9001:2015-satisfactory manufacturing facility and service repair centers Skilled certified service technicians PAC Offices Distributors

KEY FEATURES EXTENDED WARRANTY 2-year standard system warranty 10-year optics warranty on the full range, laser-referenced Michelson interferometer 5-year warranty on the IR light source SUPERIOR PERFORMANCE Compliance with ASTM, EN, ISO methods Calibration lasts for years High Resolution Wide Range FTIR - ATR Single Flow Cell Measure multiple parameters at once RELIABLE DESIGN Modern temperature-controlled laser referenced Michelson interferometer Humidity and vibration resistant ZnSe mirrors, beam splitters and non-moving sample cell LOW COST OF OWNERSHIP One instrument measures all types of samples without the need for extra hardware On-site, fast and minimal maintenance Low cost of consumables $ USER-FRIENDLY INTERFACE Intuitive interface requires minimal user training Large touch-screen allows easy navigation On-system, one-button-push model update with regional samples One-step, rapid calibration transfer and cloning

INCLUDED PARAMETERS Every OptiFuel comes with more than 50 different calibration models built using hundreds of reallife samples of gasoline, diesel and jet fuel, from all over the globe. These calibration ranges are based on current factory models, but they all can easily be expanded in the field. Calibrations can easily be cloned and transferred to additional units. GASOLINE DIESEL JET FUEL GASOLINE DIESEL ETHANOL METHANOL DIESEL Properties 1 Range 2 Research Octane Number (RON) 89-103 Motor Octane Number (MON) 80-93 Anti Knock Index (AKI) 85-98 Distillation Points IBP 25-50 C (77-122 F) T10 38-67 C (91-153 F) T50 66-117 C (150-243 F) T90 123-178 C (253-122 F) FBP 171-221 C (340-430 F) Evaporation Points E70 11-53 v% E100 32-75 v% E150 79-97 v% E180 90-99 v% E200 29-74 v% E300 77-100 v% DVPE 42-108 (kpa) Drivability Index 860-1300 Vapour Lock Index (VLI) 500-1450 MTBE 0-20 v% ETBE 0-20 v% TAME 0-20 v% Methanol 0-10 v% Ethanol 0-100 v% DIPE 0-20 v% tert-butanol 0-15 v% Total Oxygen 0-50 m% Olefins 0-28 v% Total Aromatics 0-50 v% Aromatics C7 0.8-18 v% Aromatics C8 0.5-16 v% Benzene 0-6 v% MMT 0-20000 mg/l Manganese 0-5000 mg/l VOC 1040-2171 mg/mi VOC Performance -27.6 to 48.1% Saturates 0-100 v% Density (built-in U-tube cell) 0.5-2 g/cm 3 Properties 1 Range 2 Cetane Number 41-66 Cetane Index 42-65 Cetane improver (2-EHN, IPN) JET FUEL 30-12000 mg/l FAME (low to high concentration) 0-100 v% Distillation Points IBP 145-220 C (293-428 F) T10 160-260 C (320-500 F) T50 T90 T95 FBP 170-295 C (338-563 F) 180-360 C (356-680 F) 260-390 C (500-734 F) 195-365 C (383-689 F) E250 5-70 v% Density (built-in U-tube cell) 0.5-2 g/cm 3 Properties 1 Range 2 FAME 0-100% Distillation Points IBP 145-220 C (293-428 F) T10 160-260 C (320-500 F) T50 T90 T95 FBP 170-295 C (338-563 F) 180-360 C (356-680 F) 260-390 C (500-734 F) 195-365 C (383-689 F) Density (built-in U-tube cell) 0.5-2 g/cm 3 JET FUEL NOTES: 1. Range and quality of prediction is related to database used. 2. The lowest concentration value is related to the Limit of Detection (LOD).

DENSITY MODULE An ASTM compliant u-tube density module is integrated in each OptiFuel to provide direct density reading from 0.5 g/cm 3 to 2.0 g/cm 3 *. This eliminates the need for an external density meter. ADDITIONAL PARAMETERS Unlimited additional properties can be added or updated quickly per user-defined requests. GASOLINE DIESEL JET FUEL Sum Parameters Oxygenates Esters Di-Olefins Oxygenates Iso-Propanol 2-Butanol Dimethoxymethane (DMM) Dimethylcarbonate (DMC) Methylacetate Ethylacetate Isobutylacetate Sec-Butylacetate TAEE Anilines Aniline N-Methylaniline o-methoxyaniline o-, m-, p-toluidine N,N-Dimethylaniline GASOLINE DIESEL JET FUEL Aromatics Toluene o-, m-, p-xylene Ethylbenzene Propylbenzene 2-Ethyltoluene 3-Ethyltoluene 4-Ethyltoluene Pseudocumene Hemellitol Mesitylene Iso-Durene Durene Naphthalene Other aromatics Octane Boosters CMT Dicyclopentadiene (DCPD) Others RVP * Per ASTM D1250-04 algorithm, 0.6 1.200 g/cm 3 at 15 C Recovered Points CFPP Viscosity Total Aromatics Polynuclear Aromatics (PNA) Benzene Dimethoxymethane FAAE Vegetable Oil JET FUEL GASOLINE DIESEL ETHANOL METHANOL METHANOL Methanol Density Global sample database analyzed by Freezing Point Flash Point Smoke Point Viscosity Total Aromatics Polynuclear Aromatics (PNA) JET FUEL GASOLINE ETHANOL DIESEL ETHANOL METHANOL Ethanol Water Methanol Denaturant TM

ROAD-TESTED FOR MOBILE APPLICATIONS OptiFuel comes in a rugged, yet elegant, design with a friendly user interface, which makes it ideal for refineries, pipelines, terminals and mobile labs. We used only the best materials to ensure it delivers unmatched performance in any application, and tested through intense shock, vibration and drop, per ASTM and MilSpec. MOBILE ACCESSORY PACKAGE 24V 12 VDC Auto Port Adapter Battery Pack NOTE: OptiFuel runs for more than 5 uninterrupted hours on just the battery pack, untethered from a vehicle or an external power outlet.

COMPLETE CONNECTIVITY Easily connect your OptiFuel to your network printer or LIMS system. You can also digitally clone your OptiFuel with a USB drive. LIMS PRINTER USB METHOD-APPROVED Compliance Correlation Method Applications Benzene: ASTM D6277 EN 238 FAME: ASTM D7371 EN 14078 Oxygenates: (MTBE, ETBE, TAME, DIPE, Methanol, Ethanol, tert-butanol) ASTM D5845 Density: ASTM D7777 ISO 15212 IP 559 ASTM: D2699 D2700 D5191 D86 D4815 D6839 D613 D4737A D4053 D7806 EN 14078 SGS M2533 EN ISO 405 EN ISO 5164 EN ISO 5163 EN ISO 13016/1 EN ISO 3405 EN ISO 22854 EN ISO 5165 EN ISO 4264 Provides correlation result for methods in specification: D975 D1655 D4814 EN 228 EN 590 DEFSTAN 91-091 PAC SOLUTIONS FOR PIPELINES, TERMINALS AND MOBILE LABS OptiFlash Small Scale Flash Point Analyzer PMD 110 Micro Distillation Analyzer VIDA Density Meter

TECHNICAL SPECIFICATIONS Spectrometer Type FTIR Michelson Interferometer - Thermally controlled laser referenced Standard Test Methods Compliance: Benzene: ASTM D6277, EN 238 FAME: ASTM D7371 Oxygenates (MTBE, ETBE, TAME, DIPE, Methanol, Ethanol, tert-butanol): ASTM D5845 Density: ASTM D7777, IP 559 Correlation: ASTM D7806, D2699, D2700, D5191, D86, D4814, D6839, D613, D4737A, D4052, ISO 15212, E1655, EN ISO 3405, EN 14078, EN ISO 5164, EN ISO 5163, 13016/1, 3405, 22854, 5165, 4264, SGS M2533 and others. Mirror Design Friction-free, vibration resistant, cube corner mirror Mirror and Beam Splitter Humidity resistant Zinc Selenide Density Measurement Oscillating U-tube cell with temperature sensor Units of Measurement %m, %v Scan Range 550-4000 cm -1 Spectral Resolution 2 cm -1 Measurement Time 60 seconds Sample Introduction From sample container Sample Volume 8 ml Calibration Factory calibrated with matrix of several hundred global fuels Regional Calibration Update Yes Cleaning Solvent Operating Temperature 5 C to 45 C Humidity 0% to 90% RG Storage Temperature -40 C to +85 C Leak Test Automatic Filter Replacement Monitor Automatic Fume Sensor Yes Real-time Safety Monitoring Yes Display 7" color touch screen Interface 3x USB - 1x Ethernet Instrument Memory 100,000 test results Power Requirements 110V to 230V - 50/60 Hz, 60 W. 24V battery pack option available, connectable to 12V. Dimensions 8.5 x 14 x 16 (W x H x D) Weight 32 lbs (14.5 kg) Packaging Certifications 24" x 24" x 24" (W x H x D) - 56lbs (25.4 kg) ISO 9001, CE, ROHS, CSA Continuing research and development may result in specifications or appearance changes at any time ABOUT PAC PAC develops advanced instrumentation for lab and process applications based on strong Analytical Expertise that ensures Optimal Performance for our clients. Our analyzers help our clients meet complex industry challenges by providing a low cost of ownership, safe operation, high performance with fast, accurate, and actionable results, high uptime through reliable instrumentation, and compliance with standard methods. Our solutions are from industry-leading brands: AC Analytical Controls, Advanced Sensors, Alcor, Antek, Herzog, ISL, Cambridge Viscosity, PSPI, and PetroSpec. We are committed to delivering superior and local customer service worldwide with 16 office locations and a network of over 50 distributors. PAC operates as a unit of Roper Technologies, Inc., a diversified technology company and a constituent of S&P 500, Fortune 1000, and Russell 1000 indices. HEADQUARTERS PAC LP 8824 Fallbrook Drive Houston, Texas 77064 USA www.paclp.com Contact us for more details. Visit our website to find the PAC representative closest to you. Copyright 2017 PAC L.P. All rights reserved OptiFuel Brochure US - Rev.1-10/17